Et11A

  • f

/ps nuc o

'o, UNITED STATES I '$,3 4.

i NUCLEAR REGULATORY COMMISSION c

WASHINGTON, D. C. 20555 o,

WEPTEMBER 13 W9 Docket Nos. 50-282 and 50-306 Mr. L. O. Mayer, Manager Nuclear Support Services Northern States Power Company 414 Nicollet Mall - 8th Floor Minneapolis, Minnesota 55401

Dear Mr. Mayer:

RE:

REACTOR CAVITY SEAL RING GENERIC ISSUE (PWR)

We have completed our review of your response to our letter of February 2, 1978, in regard to the potential for the reactor cavity annulus seal ring to become a destructive missile in the event of a loss-of-coolant accident pipe break inside the reactor cavity.

Your response acceptably resolves this issue for Prairie Island Nuclear Generating Station, Unit Nos.1 and 2.

Sincerely /

I g

ayVMO A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors cc:

See next page 7910050 3 6 o jj26 2/6

4 tir. L. O. Mayer Northern States Power Company cc:

Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.

Washington, D. C.

20036 Sandra S. Gardebring Executive Director Minnesota Pollution Control Agency 1935 W. County Road 82 Roseville, Minnesota 55113 The Environmental Conservation Library Minneapolis Public Library 300 Nicollet Mall Minneapolis, Minnesota 55401 Mr. F. P. Tierney, Plant Manager Prairie Island Nuclear Generating Plant Northern States Power Company Route 2 Welch, Minnesota 55089 Joclyn F. Olson, Esquire Special Assistant Attorney General Minnesota Pollution Control Agency 1935 W. County Road B2 Rosevil:e, Minnesota 55113 Robert L. Nybo, Jr., Chairman Minnesota-Wisconsin Boundary Area Commission 619 Second Street Hudson, Wisconsin 54016 Clarence D. Fierabend U. S. Nuclear Regulatory Commission P. O. Box 374 Red Wing, Minnesota 55066 1126 2/7