MONTHYEARML19270G8051979-05-15015 May 1979 Summary of 790511 Meeting W/Util in Bethesda,Md Re Auxiliary Feedwater Sys.List of Attendees & Matl Discussed Encl Project stage: Meeting ML20150F1621979-05-22022 May 1979 Submits Formal Responses to 790510 Questionnaire Re Pressurizer Heater,Loss of Feedwater Event & Steam Generator Project stage: Other ML19225C9181979-06-0404 June 1979 Requests Status of Lll Electrical Staff Overpressure & Flooding Reviews Project stage: Request ML19246C4101979-06-11011 June 1979 Forwards NRC to Westinghouse Requesting Addl Info Re Small Break LOCA Analyses & Analysis Methods.Nrc Will Eventually Require Documentation Re Applicability of Westinghouse Results to Analyses at Facility Project stage: Other ML19209A4201979-09-21021 September 1979 Forwards NRC Requirements for Auxiliary Feedwater Sys & Requests That Plant Designs & Procedures Be Evaluated Against Applicable Requirements to Determine Degree of Conformity Project stage: Other ML19259D6551979-10-20020 October 1979 Forwards Response to NRC Requesting Commitments to Implement NUREG-0578 Recommendations.Design Differences Decrease Chance of TMI-type Accident Project stage: Request ML19290B7341979-10-29029 October 1979 Submits Partial Response to Re short-term & long-term Requirements for Auxiliary Feedwater Sys.Requests Extension Until 800131 for Remaining Requirements Project stage: Other ML19320D5181979-12-0707 December 1979 Seventy-Two Hour Test of Turbine-Driven Auxiliary Feed Pump Project stage: Other ML19256G1021979-12-17017 December 1979 Responds to NRC 791210 Request for Addl Info on TMI Lessons Learned Task Force Recommendations Re Auxiliary Feedwater Sys.Oversize Drawings Available in Central Files Project stage: Request ML19256G2521979-12-17017 December 1979 Forwards Modified Response to Previous Commitment to Implement NUREG-0578.Util Will Provide Alarms in Addition to Existing Position Indication for Power Operated Relief Valves for Both Units Project stage: Other ML19320D5261979-12-23023 December 1979 Seventy-Two Hour Test of Electrically-Driven Auxiliary Feed Pumps Project stage: Other ML19320D5231979-12-26026 December 1979 Seventy-Two Hour Test of Electrically-Driven Auxiliary Feed Pump Project stage: Other ML19320D5111979-12-28028 December 1979 Seventy-Two Hour Test of Turbine-Driven Auxiliary Feed Pump Project stage: Other ML19257C5411980-01-22022 January 1980 Forwards Small Break LOCA Operator Guidelines.Min RCS Subcooling Margin Set at 36 F Prior to Terminating Safety Injection Project stage: Other ML19260D8281980-02-0404 February 1980 Responds to NRC 790921 Request for Evaluation of Requirements for Auxiliary Feedwater Sys & Associated Schedule & Commitment for Implementation of Required Changes & Actions Project stage: Request ML19316A7831980-05-16016 May 1980 Forwards Request for Addl Responses to NRC Long & short-term Recommendations Re Auxiliary Feedwater Sys.Open Items Must Be Resolved Acceptably Before Safety Evaluation Can Be Issued.Responses Needed within 45 Days Project stage: Approval ML19320D5021980-07-0808 July 1980 Revised Tech Spec 15.3.4 for Steam & Power Conversion Sys Project stage: Other ML19320D4771980-07-0808 July 1980 Forwards Revised Tech Spec 15.3.4 for Steam & Power Conversion Sys & Four 72-h Test Repts for Auxiliary Feed Pump in Response to NRC 800516 Request for Addl Info Re Auxiliary Feedwater Sys Project stage: Request ML19350D3491981-04-0909 April 1981 Responds to 810127 Request for Response to Unresolved Items Identified in Safety Evaluation for Auxiliary Feedwater Sys, Including short-term Recommendation GS-1 Re Tech Specs & Recommendation Re Redundant Level Indications Project stage: Request ML20009C7371981-07-16016 July 1981 Forwards Response to Generic Ltr 81-14 Re Seismic Qualification of Auxiliary Feedwater Sys.Sys Is Adequately Protected for Seismic Event Project stage: Other ML20040G4761982-01-25025 January 1982 Forwards Request for Addl Info Re Response to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys Project stage: RAI ML20041G4231982-03-16016 March 1982 Submits Synopsis of Items Discussed During 820302 Telcon Re Automatic Initiation Features of Auxiliary Feedwater Sys Project stage: Other ML20052C0921982-04-27027 April 1982 Tech Spec Change Request 76 Consisting of Tech Spec Pages 15.3.4-1,-2 & -2.a Re Auxiliary Feedwater Pump Project stage: Other ML20052C0861982-04-27027 April 1982 Application for Amend to Licenses DPR-24 & DPR-27,consisting of Tech Spec Change Request 76.Amend Would Incorporate NRC Changes to Limit Unavailability of Auxiliary Feedwater Pumps Project stage: Request ML20052F2161982-05-0404 May 1982 Forwards Addl Response to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Major Mechanical Components Seismically Qualified Except Condensate Storage Tanks Project stage: Other ML20054K8491982-06-30030 June 1982 Proposed Tech Spec Changes Re Periodic Testing of Auxiliary Feedwater Sys Automatic Actuation Logic Project stage: Other ML20054K8471982-06-30030 June 1982 Forwards Revision to Tech Spec Table 15.4.1-1 Re Periodic Testing of Auxiliary Feedwater Sys Automatic Actuation Logic.Nrc Review of Tech Spec Change Request 76 Should Include Addl Change Project stage: Other ML20062G6841982-07-27027 July 1982 Amends 62 & 67 to Licenses DPR-24 & DPR-27,respectively, Changing Tech Specs to Modify Limiting Conditions for Operation Re Auxiliary Feedwater Pump Operation Project stage: Other ML20062G6931982-07-27027 July 1982 Notice of Issuance & Availability of Amends 62 & 67 to Licenses DPR-24 & DPR-27,respectively Project stage: Other ML20028A7531982-11-12012 November 1982 Requests Encl Contractor Technical Evaluation Rept Re Seismic Qualification of Auxiliary Feedwater Sys Be Reviewed & Comments Provided by 821220 Project stage: Other ML20067D6311982-12-15015 December 1982 Comments on Technical Evaluation Rept Re Seismic Qualification of Auxiliary Feedwater Sys,Per 821112 Request. Recommendation to Acquire Complete SSE Level of Seismic Capacity Constitutes Unnecessary & Expensive Backfit Project stage: Other ML20064L8991983-02-11011 February 1983 Advises That Installation of Addl Supports for Auxiliary Feedwater Sys Piping & Components Rescheduled to June 1983, Due to Conflicts W/Other Plant Mods Project stage: Other ML20082A6251983-11-11011 November 1983 Advises That Auxiliary Feedwater Sys Operability Mods Completed Per Tech Spec Revs Proposed in 820427,0505 & 0630 Ltrs Project stage: Other ML20080B5531984-01-31031 January 1984 Provides Addl Info Re Status of Auxiliary Feedwater Sys Mods Implemented in Response to Generic Ltr 81-14.Last Remaining Mod Involves Replacement of Battery Rack Support Straps & Should Be Completed by Oct 1984 Project stage: Other ML20091J8581984-05-23023 May 1984 Emergency Operating Procedure Validation Procedure Project stage: Other ML20100J0891984-12-0404 December 1984 Provides Final Responses to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Support Straps on Battery Racks Replaced as Scheduled in Project stage: Other ML20116D2981985-04-22022 April 1985 Notifies That Installation of Low Suction Pressure Automatic Trips on Auxiliary Feedwater Pumps Expected to Be Completed by 860131,in Response to NRC Request for Commitment Date Project stage: Request ML20206S7491986-05-31031 May 1986 Evaluation of Structural Aspects Re Point Beach Plant Project stage: Other ML20206S6861986-09-16016 September 1986 Forwards Safety Evaluation & Technical Evaluation Rept on Util 850426 Response to Open Items Re Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Addl Info Requested Re Diesel Generator Room Flooding Project stage: Approval ML20206S7091986-09-16016 September 1986 Safety Evaluation on Util 850426 Response to Open Items Re Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys (Afws). Reasonable Assurance Exists That Afws Will Perform Required Safety Function Following SSE Project stage: Approval ML20215N8401986-10-31031 October 1986 Advises of Features & Mods to Diesel Generator Room Air Exhaust Duct Louvers & Diesel Generator Voltage Regulator Cabinets in Response to Concerns Expressed in 860916 Safety Evaluation Re Util Compliance W/Generic Ltr 81-14 Project stage: Other ML20209H2971987-01-21021 January 1987 Advises That Mods to Protect Diesel Generator Voltage Regulator Cabinets from Fire Protection Sprinkler Operation Adequately Address NRC Concerns Identified in 860916 Safety Evaluation,Per Util Project stage: Approval 1981-07-16
[Table View] |
Text
1 Wisconsin Electnc powracoupsur 231 WEST MICHIGAN, MILWAUKEE, WISCONSIN 53201 December 17, 1979 Mr. Harold R.
Denton, Director Office of Nuclear Reactor Regulation U. S. NUCLEAR REGULATORY COMMISSION Washington, D.
C.
20555
Dear Mr. Denton:
DOCKETS 50-266 and 50-301 IMPLEMENTATION OF NUREG-0578 POINT BEACH NUCLEAR PLANT, UNITS 1 and 2 The attachments to this letter supplement and modify our responses concerning implementation of NUREG-0578 which were submitted on October 20 and November 27, 1979.
This letter concerns Items 2.1.7.b, 2.2.1.b, and 2.2.2.a and confirms telephone discussions with Messrs. Trammell and Olshinski on December 14, 1978.
Confirming the December 4, 1979 telephone conversation between Mr. C. Trammell of your staff and our Dr.
E.
J.
- Lipke, it is our intent to provide alarms in addition to the existing position indication for the power-operated relief valves for both units at Point Beach Nuclear Plant by January 1, 1980.
We understand that these modified responses satisfy presently outstanding concerns related to the implementation of NUREG-0578 requirements at the Point Beach Nuclear Plant.
Very truly yours,
^
n 1 u/
Exec ive Vice President dol Burstein Attachments s
///
r.
1653 282
2.1.7.b AUXILIARY FEEDWATER FLOW INDICATION TO STEAM GENERATORS FOR PWR'S Commitment The flow indication instrumentation described in the Octob3r 20, 1979 submittal will be installed by January 1, 1980.
The operator presently has auxiliary feedwater pump discharge pressure indication available in the control room.
This configuration of flow and pressure will provide the capability in the control room to ascertain the actual performance of the auxiliary feedwater system.
Additional flow instrumentation will be installed to indicate the auxiliary feedwater flow going to each stea, generator.
This instrumentation will be safety grade and installed by January 1, 1981.
The design of this system will meet the requirements as clarified in the NRC October 30, 1979 letter.
1653 283
2.2.1.b SHIFT TECHNICAL ADVISOR Commitment A Technical Advisor will be available at all times to be capable of being in the control room within ten minutes of being called to report to that location.
During non-working hours, this Advisor will be either in the plant or in close proximity, such as in the Energy Information Center, immediately adjacent to the plant.
Procedure (s) will be provided specifying that the Duty Technical Advisor shall report directly to the control room in the event of an accident, but shall have no direct manipulative responsibilities or functions in the control room during an emergency.
The Duty Technical Advisor shall be provided with constant means of communication with the control room.
Initially, the designated Duty and Call Technical Advisors will be engineers.having a minimum bachelor cf science degree.
1653 284
2.2.2.a CONTROL ROOM ACCESS Commitment The policy described in our letters of October 20 and November 27, 1979 will be modified to include the following regarding the number of NRC personnel to be granted access:
"NRC personnel access will be limited and controlled as agreed between the senior Wisconsin Electric official on site and the senior NRC person on site."