MONTHYEARML19270G8051979-05-15015 May 1979 Summary of 790511 Meeting W/Util in Bethesda,Md Re Auxiliary Feedwater Sys.List of Attendees & Matl Discussed Encl Project stage: Meeting ML20150F1621979-05-22022 May 1979 Submits Formal Responses to 790510 Questionnaire Re Pressurizer Heater,Loss of Feedwater Event & Steam Generator Project stage: Other ML19225C9181979-06-0404 June 1979 Requests Status of Lll Electrical Staff Overpressure & Flooding Reviews Project stage: Request ML19246C4101979-06-11011 June 1979 Forwards NRC to Westinghouse Requesting Addl Info Re Small Break LOCA Analyses & Analysis Methods.Nrc Will Eventually Require Documentation Re Applicability of Westinghouse Results to Analyses at Facility Project stage: Other ML19209A4201979-09-21021 September 1979 Forwards NRC Requirements for Auxiliary Feedwater Sys & Requests That Plant Designs & Procedures Be Evaluated Against Applicable Requirements to Determine Degree of Conformity Project stage: Other ML19259D6551979-10-20020 October 1979 Forwards Response to NRC Requesting Commitments to Implement NUREG-0578 Recommendations.Design Differences Decrease Chance of TMI-type Accident Project stage: Request ML19290B7341979-10-29029 October 1979 Submits Partial Response to Re short-term & long-term Requirements for Auxiliary Feedwater Sys.Requests Extension Until 800131 for Remaining Requirements Project stage: Other ML19320D5181979-12-0707 December 1979 Seventy-Two Hour Test of Turbine-Driven Auxiliary Feed Pump Project stage: Other ML19256G1021979-12-17017 December 1979 Responds to NRC 791210 Request for Addl Info on TMI Lessons Learned Task Force Recommendations Re Auxiliary Feedwater Sys.Oversize Drawings Available in Central Files Project stage: Request ML19256G2521979-12-17017 December 1979 Forwards Modified Response to Previous Commitment to Implement NUREG-0578.Util Will Provide Alarms in Addition to Existing Position Indication for Power Operated Relief Valves for Both Units Project stage: Other ML19320D5261979-12-23023 December 1979 Seventy-Two Hour Test of Electrically-Driven Auxiliary Feed Pumps Project stage: Other ML19320D5231979-12-26026 December 1979 Seventy-Two Hour Test of Electrically-Driven Auxiliary Feed Pump Project stage: Other ML19320D5111979-12-28028 December 1979 Seventy-Two Hour Test of Turbine-Driven Auxiliary Feed Pump Project stage: Other ML19257C5411980-01-22022 January 1980 Forwards Small Break LOCA Operator Guidelines.Min RCS Subcooling Margin Set at 36 F Prior to Terminating Safety Injection Project stage: Other ML19260D8281980-02-0404 February 1980 Responds to NRC 790921 Request for Evaluation of Requirements for Auxiliary Feedwater Sys & Associated Schedule & Commitment for Implementation of Required Changes & Actions Project stage: Request ML19316A7831980-05-16016 May 1980 Forwards Request for Addl Responses to NRC Long & short-term Recommendations Re Auxiliary Feedwater Sys.Open Items Must Be Resolved Acceptably Before Safety Evaluation Can Be Issued.Responses Needed within 45 Days Project stage: Approval ML19320D5021980-07-0808 July 1980 Revised Tech Spec 15.3.4 for Steam & Power Conversion Sys Project stage: Other ML19320D4771980-07-0808 July 1980 Forwards Revised Tech Spec 15.3.4 for Steam & Power Conversion Sys & Four 72-h Test Repts for Auxiliary Feed Pump in Response to NRC 800516 Request for Addl Info Re Auxiliary Feedwater Sys Project stage: Request ML19350D3491981-04-0909 April 1981 Responds to 810127 Request for Response to Unresolved Items Identified in Safety Evaluation for Auxiliary Feedwater Sys, Including short-term Recommendation GS-1 Re Tech Specs & Recommendation Re Redundant Level Indications Project stage: Request ML20009C7371981-07-16016 July 1981 Forwards Response to Generic Ltr 81-14 Re Seismic Qualification of Auxiliary Feedwater Sys.Sys Is Adequately Protected for Seismic Event Project stage: Other ML20040G4761982-01-25025 January 1982 Forwards Request for Addl Info Re Response to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys Project stage: RAI ML20041G4231982-03-16016 March 1982 Submits Synopsis of Items Discussed During 820302 Telcon Re Automatic Initiation Features of Auxiliary Feedwater Sys Project stage: Other ML20052C0921982-04-27027 April 1982 Tech Spec Change Request 76 Consisting of Tech Spec Pages 15.3.4-1,-2 & -2.a Re Auxiliary Feedwater Pump Project stage: Other ML20052C0861982-04-27027 April 1982 Application for Amend to Licenses DPR-24 & DPR-27,consisting of Tech Spec Change Request 76.Amend Would Incorporate NRC Changes to Limit Unavailability of Auxiliary Feedwater Pumps Project stage: Request ML20052F2161982-05-0404 May 1982 Forwards Addl Response to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Major Mechanical Components Seismically Qualified Except Condensate Storage Tanks Project stage: Other ML20054K8491982-06-30030 June 1982 Proposed Tech Spec Changes Re Periodic Testing of Auxiliary Feedwater Sys Automatic Actuation Logic Project stage: Other ML20054K8471982-06-30030 June 1982 Forwards Revision to Tech Spec Table 15.4.1-1 Re Periodic Testing of Auxiliary Feedwater Sys Automatic Actuation Logic.Nrc Review of Tech Spec Change Request 76 Should Include Addl Change Project stage: Other ML20062G6841982-07-27027 July 1982 Amends 62 & 67 to Licenses DPR-24 & DPR-27,respectively, Changing Tech Specs to Modify Limiting Conditions for Operation Re Auxiliary Feedwater Pump Operation Project stage: Other ML20062G6931982-07-27027 July 1982 Notice of Issuance & Availability of Amends 62 & 67 to Licenses DPR-24 & DPR-27,respectively Project stage: Other ML20028A7531982-11-12012 November 1982 Requests Encl Contractor Technical Evaluation Rept Re Seismic Qualification of Auxiliary Feedwater Sys Be Reviewed & Comments Provided by 821220 Project stage: Other ML20067D6311982-12-15015 December 1982 Comments on Technical Evaluation Rept Re Seismic Qualification of Auxiliary Feedwater Sys,Per 821112 Request. Recommendation to Acquire Complete SSE Level of Seismic Capacity Constitutes Unnecessary & Expensive Backfit Project stage: Other ML20064L8991983-02-11011 February 1983 Advises That Installation of Addl Supports for Auxiliary Feedwater Sys Piping & Components Rescheduled to June 1983, Due to Conflicts W/Other Plant Mods Project stage: Other ML20082A6251983-11-11011 November 1983 Advises That Auxiliary Feedwater Sys Operability Mods Completed Per Tech Spec Revs Proposed in 820427,0505 & 0630 Ltrs Project stage: Other ML20080B5531984-01-31031 January 1984 Provides Addl Info Re Status of Auxiliary Feedwater Sys Mods Implemented in Response to Generic Ltr 81-14.Last Remaining Mod Involves Replacement of Battery Rack Support Straps & Should Be Completed by Oct 1984 Project stage: Other ML20091J8581984-05-23023 May 1984 Emergency Operating Procedure Validation Procedure Project stage: Other ML20100J0891984-12-0404 December 1984 Provides Final Responses to Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Support Straps on Battery Racks Replaced as Scheduled in Project stage: Other ML20116D2981985-04-22022 April 1985 Notifies That Installation of Low Suction Pressure Automatic Trips on Auxiliary Feedwater Pumps Expected to Be Completed by 860131,in Response to NRC Request for Commitment Date Project stage: Request ML20206S7491986-05-31031 May 1986 Evaluation of Structural Aspects Re Point Beach Plant Project stage: Other ML20206S6861986-09-16016 September 1986 Forwards Safety Evaluation & Technical Evaluation Rept on Util 850426 Response to Open Items Re Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys. Addl Info Requested Re Diesel Generator Room Flooding Project stage: Approval ML20206S7091986-09-16016 September 1986 Safety Evaluation on Util 850426 Response to Open Items Re Generic Ltr 81-14, Seismic Qualification of Auxiliary Feedwater Sys (Afws). Reasonable Assurance Exists That Afws Will Perform Required Safety Function Following SSE Project stage: Approval ML20215N8401986-10-31031 October 1986 Advises of Features & Mods to Diesel Generator Room Air Exhaust Duct Louvers & Diesel Generator Voltage Regulator Cabinets in Response to Concerns Expressed in 860916 Safety Evaluation Re Util Compliance W/Generic Ltr 81-14 Project stage: Other ML20209H2971987-01-21021 January 1987 Advises That Mods to Protect Diesel Generator Voltage Regulator Cabinets from Fire Protection Sprinkler Operation Adequately Address NRC Concerns Identified in 860916 Safety Evaluation,Per Util Project stage: Approval 1981-07-16
[Table View] |
Text
.
. 4, vt
[,. m r.,
'c UNITED STATES U Lu:;;% i. ;-6m '
NUCLEAR REGULATORY COMMISSION 8 b,.
- J,(f!g,,$
WASHINGTON, D. C. 20555
'[ <
{,
QcN'/
JUNE I 1 1979
,,g.
Docket Nos 50-2 F N e'and'501301
)
i Mr.\\ Sol Burstejn Exec 0the4fce Pr?sident Wisconsin Electric Power Company 231 West Michigan Street Milwaukee, Wisconsin 53201
Dear !!r. Burstein:
SUBJECT:
INFORMATION COPY OF REQUEST FOR ADDITIONAL INFORMATION REGARDING WESTINGHOUSE SMALL BREAK LOCA ANALYSIS As we discussed with you during our meeting on May 30, 1979, the NRC staff is evaluating certain aspects of the NRC licensing process in light of the Three Mile Island Unit 2 (TMI-2) accident of March 28, 1979. One of the aspects Ming addressed by the staff in its evaluation is the status of the mod #; used in safety analys
, especially with regard to transients and small break LOCAs. Enclo> J is a copy of an NRC letter, dated June 4,1979, requesting infomation fran your nuclear steam supply vendor, the Westinghouse Electric Corpora' ion, regarding small break LOCA analyses and an6'ysis methods.
This.:nclosure is provided for your infomation.
It is our understanding that you are participating in this effort as it applies to your licensed power plants thr ugh an owners group.
At some point in this effort we will require that you document the applicability of the results of these Westinghousa analyses to your plants.
To that end, a copy of all cor:espondence to Westinghouse and the cwners group on this matter will be provided to you and placed in our files on your specific plants.
Please contact P. D. O'Reilly, the staff's assigned project manager -
fr this matter, if you have any questions.
Sincerely, h&$$
. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors m
009 Er.cl osure:
l,RC June 4,1979 letter to Westinghouse cc: w/ enclosures See next page gg$l!{
per 4.
Mr. Sol Burste.in JUNE I 1 1979
)
Wisconsin. Electric Power Company E
cc: Mr. Bruce Churchill, Esquire I
Shaw, Pittman, Potts and Trowbridge l
1800 M Street, N.W.
?
Washington, D. C.
20036 Document Department l
University of Wisconsin Stevens Point Library
[
Stevens Point, Wisconsin 54481
~
Mr. Glen Reed, Manager Nuclear Power Division Point Beach Nuclear Plant Wisconsin Electric Power Company i
231 West Michigan Street I-Milwaukee, Wisconsin 43201
?
h k
s 426 010
e muco UNITED STATES NUCLEAR REGULATORY COMMISSION 3e E
W ASHINGTON, D. C. 20555
$o, V 9
/
'%..* /
JUN ;
1979 Mr. Tom M. Anderson, Manager Nuclear Safety Department Westinghouse Electric Corporation P. O. Box 355 Pittsburgh, Pennsylvania 15230
Dear Mr. Anderson:
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING SMALL BREAK LOCA ANALYSIS As you are aware, the NRC staff is evaluating certain aspectc of the NRC licensing process in ligM of the Three Mile Island Unit 2 (TMI-2) accident, of March 28, 1979. One of the aspects being addressed in this evaluation is the status of models used in safety analyses, especialiy those used to analyze transients and small break LOCA's.
In order for the staff to complete its evaluation of the response of currently operating Westinghouse-designed plants to postulated small break LOCA's, additional information is required. These information needs, which pertain to expected system behavior following postulated small break LOCA's and small break LOCA analysis methods and results, are identified in the enclosure to this letter.
Please provide, within seven days of the date of receipt of this letter, your schedule for responding to the items contained in the enclosure. We recognize that some of the requested information may have already been provided to the staff in the course of other reviews.
In lieu of refer-encing already submitted material, we would prefer, in order to facilitate our review, that the responses be provided in one complete document.
The information contained in the enclosure was discussed with your repre-sentatives at our May 31,1979 meeting.
If you have any question regarding the contents of this letter please contact P. D. O'Reilly, the assigned project manager.
d DUPLICATE DOCUMENT into system under: Entire document p t
e,,
e ANO No. of pages:
Enclosure.
~
As stated I"" ~ ~ ~'~"'""
~
' ~ " ~ ~ ~ ^
~ ~ '
~ ~ "