Submittal of Supplement to Subsequent License Renewal Operating Licenses Application for Sufficiency Review Change Notice 1
ML19042A137
Person / Time
Site: Surry  
Issue date: 01/29/2019
From: Mark D. Sartain
Dominion Energy Services
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML19042A135 List:
References
18-448
Download: ML19042A137 (192)


Text

{{#Wiki_filter:Dominion Energy Services, Inc.

  • 5000 Dominion Boulevard, Glen Allen, VA 23060 Dominion Energy.com January 29, 2019 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001 VIRGINIA ELECTRIC AND POWER COMPANY.

SURRY POWE'R STATION {SPS) UNITS 1 AND 2 SUPPLEMENT TO SUBSEQUENT LICENSE :RENEWAL 10 CFR 50 10CFR51 10 CFR 54 Si& Domin.ion p Energy Serial No.: NRA/DEA: Docket Nos.: License Nos.: 18-448 R2' 50-280/281 DPR-32/37 OPERATING LICENSES APPLICATION FOR *suFFICIENCY REVIEW CHANGE NOTICE 1 By letter _dated October 15, 2018 (Agencywide Documents Access and Management System (ADAMS) Package Accession No. M{18291A842), Virginia Electric and Power Company (Dominion Energy Virginia) submitted an application for the *subsequent license renewal of Renewed Facility Operating License Nos. DPR-32 and DPR-37 for the Surry Power Station. In a December 3, 2018 letter, the Nuclear Regulatory Commission (NRC) issued, "Surry Power Station, Unit Nos. 1 and 2 - Determination of Acceptability and Sufficiency for Docketing, Proposed Review Schedule and Opportunity for a Hearing Regarding the Virginia Electric and Power Company's Application for Subsequent License Renewal (EPID Nos. L-2018-RNW-0023 and L-2018-RNW-0024)," (ADAMS Accession No. ML18320A188). The letter indicated that a supplement to the Subsequent License Renewal Application (SLRA) would be required by January 2019 to supp.art the sufficiency review. This letter, SPS SLRA Change Notice 1, provides the requested supplemental information. Specifically, Enclosure 1 provides the aqc;\\lys_i~- of the impacts. of;the proposed action on Atlantic sturgeon critical habitat, and essehtial fish habitat. Each Section or Table change in Enclosure 1 is indicated by change type (i.e., addition, replacement, etc.). Also provided in Enclosure 1 is the National Marine Fisheries* Service response to Dominion Energy Virginia regarding special status species and habitats and the Virginia Department df Environmental Quality response letter to the Coastal Zone Management Program.Certification. As requested, Enclosure 2 provides information needed to address aging manag.ement of steel components in the reactor pressure vessel support assembly, via a supplement to SLRA Section:*3.5.2.2.2.6. Additionally, seven other topics require the SLRA to be supplemented. Enclosure 3 provides a description of each topic and identifies the affected SLRA SE:l_.ction. includes mark-ups of affected SLRA sections being supplemented, as described in Enclosures 2 and 3. It should be noted that changes to three commitments (Items #11, #16 and #23) are reflected in Table A4.0-1 (within Enclosure 4). To aid the staff in assessing changes, Enclosures 2 and 4 show new text as underlined and deleted text as lined through.

Serial No.: 18-448 Docket Nos.: 50-280/281 SLRA Supplement for Sufficiency Review - Change Notice 1 Page 2 of 6 includes an updated revision to an industry report which was previously submitted with the SPS SLRA on October 15, 2018. If there are any questions regarding this submittal or if additional information is needed, please contact Mr. Paul Aitken at (804) 273-2818. Sincerely, Mark D. Sartain Vice President - Nuclear Engineering and Fleet Support COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by Mark D. Sartain, who is Vice President - Nuclear Engineering and Fleet Support of Virginia Electric and Power Company. He has affirmed before me that he js duly authorized to execute and file the foregoing document in behalf of that Company, and that the statements in the document are true to the best of his knowledge and belief. Acknowledged before me this 2 9-+\\.day of :J&vivo,.gJ, 2019. My Commission Expires: rrlo.vrl1 3 I.1 2.0Z'Z.. ~~~ Commitments made in this letter: None.

Enclosures:

Notary Public DIANE E. AITKEN NOTARY PUBLIC REG. #7763114 COMMONWEALTH OF VIRCINIA flt COMMISSION EXPIRES MARCH 31, 2022 1 - Appendix E - Environmental Report Supplement - January 2019 - Analysis of Critical Habitat and Essential Fish Habitat - National Marine Fisheries Service response letter to Dominion Energy Virginia's Letter Regarding Special Status Species and Habitat - Virginia Department of Environmental Quality CZMA response letter 2 - Reactor Vessel Support Steel Aging Evaluation 3 - Other Topics That Require a SLRA Supplement 4 - SLRA Mark-ups - Change Notice 1 5 - PWROG-17011-N P, Revision 2

/ cc: (w/o Enclosures except *) Serial No.: 18-448 Docket Nos.: 50-280/281 SLRA Supplement for Sufficiency Review - Change Notice 1 Page 3 of 6 U.S. Nuclear Regulatory Commission, Region II* Marquis One Tower 245 Peachtree Center Avenue, NE Suite 1200 Atlanta, Georgia 30303-1257 NRC Senior Resident Inspector Surry Power Station Mr. Emmanuel Sayoc* NRC Project Manager U.S. Nuclear Regulatory Commission One White Flint North Mail Stop O 11 F1 11555 Rockville Pike Rockville, Maryland 20852-2738 Mr. Tam Tran* NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop O 11 F1 11555 Rockville Pike Rockville, Maryland 20852-2738 Ms. Karen Cotton NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike. Rockville, Maryland 20852-2738 Mr. James R. Hall NRC Senior Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 B1-A 11555 Rockville Pike Rockville, Maryland 20852-2738

Serial No.: 18-448 Docket Nos.: 50-280/281 SLRA Supplement for Sufficiency Review - Change Notice 1 State Health Commissioner Virginia Department of Health James Madison Building - ih Floor 109 Governor Street Room 730 Richmond, Virginia 23219 Mr. David K. Paylor, Director Virginia Department of Environmental Quality P.O. Box 1105 Richmond, VA 23218 Ms. Melanie D. Davenport, Director Water Permitting Division Virginia Department of Environmental Quality P.O. Box 1105 Richmond, VA 23218 Ms. Bettina Rayfield, Manager Office of Environmental Impact Review Virginia Department of Environmental Quality P.O. Box 1105 Richmond, VA 23218 Mr. Michael Dowd, Director Air Division Virginia Department of Environmental Quality P.O. Box 1105 Richmond, VA 23218 Mr. Justin Williams, Director Division of Land Protection and Revitalization Virginia Department of Environmental Quality P.O. Box 1105 Richmond, VA 23218 Mr. James Golden, Regional Director Virginia Department of Environmental Quality Piedmont Regional Office 4949-A Cox Road Glen Allen, VA 23060 Mr. Craig R. Nicol, Regional Director Virginia Department of Environmental Quality Tidewater Regional Office 5636 Southern Blvd Virginia Beach, VA 23462 Page 4 of 6

Serial No.: 18-448 Docket Nos.: 50-280/281 SLRA Supplement for Sufficiency Review - Change Notice 1 Ms. Jewel Bronaugh, Commissioner Virginia Department of Agriculture & Consumer Services 102 Governor Street Richmond, Virginia 23219 Mr. Jason Bulluck, Director Virginia Department of Conservation & Recreation Virginia Natural Heritage Program 600 East Main Street, 24th Floor Richmond, VA 23219 Mr. Robert W. Duncan, Director Virginia Department of Game and Inland Fisheries P.O. Box 90778 Henrico, VA 23228 Mr. Allen Knapp, Director Virginia Department of Health Office of Environmental Health Services 109 Governor St, 5th Floor Richmond, VA 23129 Ms. Julie Lagan, Director Virginia Department of Historic Resources State Historic Preservation Office 2801 Kensington Ave Richmond, VA 23221 Mr. Steven G. Bowman, Commissioner Virginia Marine Resources Commission 2600 Washington Ave Newport News, VA 23607 Dr. Mary Fabrizio, Professor Virginia Institute of Marine Science School of Marine Science 7509 Roper Rd, Nunnally Hall 135 Gloucester Point, VA 23062 .Ms. Angel Deem, Director Virginia Department of Transportation Environmental Division 1401 East Broad St Richmond, VA 23219 Mr. Stephen Moret,, President Virginia Economic Development Partnership 901 East Byrd St Richmond, VA 23219 Page 5 of 6

Serial No.: 18-448 Docket Nos.: 50-280/281 SLRA Supplement for Sufficiency Review - Change Notice 1 Mr. William F. Stephens, Director Virginia State Corporation Commission Division of Public Utility Regulation 1300 East Main St, 4th Fl, Tyler Bldg Richmond, VA 23219 Mr. Jeff Caldwell, Director Virginia Department of Emergency Management 10501 Trade Rd Richmond, VA 23236 Mr. Bruce Sterling, Chief Regional Coordinator Virginia Department of Emergency Management 1070 University Blvd Portsmouth, VA 23703 Mr. Sanford B. Wanner, Administrator Surry County 45 School Street Surry, VA 23883 Page 6 of 6

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 APPENDIX E ENVIRONMENTAL REPORT SUPPLEMENT JANUARY 2019 Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 1 of 26 ANALYSIS OF CRITICAL HABITAT AND ESSENTIAL FISH HABITAT Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 2 of 26 Each numbered section or table heading of the Analysis of Critical Habitat and Essential Fish Habitat provided herein is annotated to indicate if it is 'additional', 'new', or 'deleted' text. Also, the text in Section E3.7.8.5 is delineated as 'replacement' since the entire section has been replaced with the text provided.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 3 of 26 Supplement to Surry Power Station Environmental Report E3.7.8.1.7 Atlantic Sturgeon (additions} In the James River, Atlantic sturgeon staged from April through August/September in Burwells Bay to Hog Island (river mile [RM] 30), which is located in the vicinity of Surry Power Station (SPS) (Balazik et al. 2012). Telemetry data indicated that Atlantic sturgeon were present in this area from April/May through November. Females remained in the area prior to spawning even when males moved upstream in the fall. Females traveled upstream to RM 75 in a 48-hour span and then returned to the staging area around RM 30 post-spawn.. Adults then begin to disperse to sites down river throughout the rest of the fall, occupying only lower river sites by November (Hager 2011). Adults were undetected on the tracking array and are presumed to have exited the system by November/December. The 2017 Atlantic sturgeon stock assessment was conducted by the Atlantic States Marine Fisheries Commission. The stock assessment evaluated the status of Atlantic sturgeon along the Atlantic coast utilizing a variety of vetted fisheries-dependent and -independent data sets. The review panel accepted the analyses as supporting "a stable to slowly increasing population of Atlantic sturgeon" following the 1998 fishing moratorium. "The paucity of data available to develop reliable indices of abundance and the inability to distribute historical catches to specific rivers or DPSs precluded the application of traditional stock assessment methods, except at a coastwide level." (ASMFC 2018) On August 17, 2017, the NMFS issued a final rule designating critical habitat for Atlantic sturgeon (82 FR 39160). The rule covered all five distinct population segments (DPS) of Atlantic sturgeon. Critical habitat boundaries for the Chesapeake Bay DPS were defined in the final rule. For the James River, it was defined as occurring from Boshers Dam (head of tide) downstream to where the main stem river discharges at its mouth into the Chesapeake Bay at Hampton Roads. In the final rule, NMFS indicated that the designated critical habitat (OCH) was in effect the known range within each tidal-affected river. In 2018, Age-0 Atlantic sturgeon were collected for the first time from the James River by Virginla Commonwealth University (VCU) and the James River Association. As of November 2018, 153 juvenile Atlantic sturgeon were collected from the James River during routine trawl surveys by VCU, with most collected between the Benjamin Harrison Bridge near Hopewell, VA, and Sturgeon Point Uust west of Fort Pocahontas in Charles City County, VA). The James River Association collected five Age-0 Atlantic sturgeon during an education program at Presquile National Wildlife Refuge (upstream of Hopewell, VA). (Bay Journal 2018) Previous observations of juvenile Atlantic sturgeon in the James River were of older and substantially larger individuals, and regarded as yearling or older fish. In comparison, the presumed Age-0 fish from 2018 were between 2 and 4 inches (6-11 cm) in length and were presumed to have hatched within the few weeks leading up to the collection of early stage

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 4 of 26 juveniles in October 2018. Kynard et al. (2016) described the locations that one could expect to find juvenile Atlantic sturgeon. Age-0 Atlantic sturgeon would likely reside in deep water in the channel and migrate out to the margins at night to feed in the shallower reaches. Older juveniles are more mobile but mimic the feeding/foraging behavior of Age-0 fish. E3.7.8.1.14 Shortnose Sturgeon (new section) In March 2016, a single shortnose sturgeon (Acipenser brevirostrum) was collected from the James River at RM 30. This was the first verified occurrence of a shortnose sturgeon in the James River. The fish was collected as part of a VCU program monitoring Atlantic sturgeon under the National Oceanic and Atmospheric Administration (NOAA) endangered species permit No. 16547. Species identification was verified by genetic analysis by the United States Geological Survey Leetown, West Virginia, Science Center. (Balazik 2017) In February 2018, a second sturgeon (a confirmed gravid female) was captured near RM 30 (NOAA 2018a). This species is federally and state-listed as endangered. It has been designated as Tier I, critical conservation need, in the Virginia wildlife action plan (VDGIF 2018). Shortnose sturgeon are similar in appearance to Atlantic sturgeon, but can be distinguished by their smaller size, larger mouth, smaller snout shape, and scutes. The two species have a close lineage, are bottom-oriented, are morphologically similar, exhibit similar feeding behaviors, make spawning migrations, and spawn in similar habitats. Shortnose and Atlantic sturgeon are also behaviorally similar. The greatest distinction between the two is Atlantic sturgeon make coastal migrations, whereas the shortnose sturgeon tends to remain restricted to its natal river. The shortnose sturgeon can grow to approximately 4.5 feet long and weigh up to 60 pounds. They are yellowish-brown and generally have a black head, back, and sides. Their bellies are white to yellow. They have five major rows of scutes and a protruding snout with four barbels (fleshy, whisker-like projections). (NOAA 2018b) Shortnose sturgeon are amphidromous fish. They live in their birth (natal) river, make short feeding or migratory trips into salt water, and then return to freshwater to feed and escape predation. When they do enter marine waters, they generally stay close to shore. In the spring, adults move far upstream and away from salt water to spawn. After spawning, the adults move rapidly back downstream to the estuaries, where they feed, rest, and spend most of their time. (NOAA 2018b) The shortnose sturgeon's tendency to live near its home estuary coupled with their current range from the Canadian Maritimes to Georgia suggests that historically, all large rivers on the Atlantic Coast of the United States may have had natal shortnose sturgeon populations that coexisted with Atlantic sturgeon (Jenkins and Burkhead 1993). Because all sturgeons were lumped together and called "common sturgeon" in the commercial catch statistics, it is impossible to estimate historic abundance and distribution of shortnose sturgeon alone, as

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 5 of 26 capture records combined Atlantic and shortnose sturgeon until the shortnose was listed in 1973. Kynard et al. (2016) details the life stages found and adult abundance in rivers throughout its range. Absent from Kynard's discussion is the Chesapeake Bay drainage, which indicates that there is not a known reproducing population within Chesapeake Bay. Jenkins and Burkhead (1993) note that there is only one valid record of a shortnose sturgeon in the entire Chesapeake Bay pre-1900s. Commercial fishing records indicate most or all mid-Atlantic rivers historically had sturgeon populations. Despite sampling targeted for sturgeons in recent decades, there has been no documented spawning and few shortnose sturgeon captured or observed in any mid-Atlantic river. Kynard et al. (2016) explains that spawning populations throughout the range have usually been identified either by the presence of a spawning run of mature adults or by the presence of young juveniles (<1 year, too young to be tolerant of high salinity and whose movements are therefore restricted to their natal river and estuary). The capture of early life history stages and young juveniles remains the most convincing evidence of a viable spawning population. Tracking the migration of pre-spawning adults alone, without capture of early life history stages, is insufficient evidence to indicate successful spawning occurs. Kynard et al. (2016) further explains that the abundance of adults has also been used as a strong indicator of spawning success, particularly for rivers with tens of thousands of adults like the Hudson River. Recent tracking and genetic analysis of shortnose sturgeon from basins throughout the range indicates more coastal movement by shortnose sturgeon than previously recognized. Thus, throughout the range,. the presence of a few adults in a river does not mean a spawning population is present. Migrant. adult shortnose sturgeon entering rivers without a natal shortnose sturgeon population represent potential colonizers. Native populations of shortnose sturgeon were extirpated or reduced to a remnant population in many rivers, but if river habitats are available to complete their life history, coastal shortnose sturgeon migrants may find and colonize these rivers. Until the Qbservation of a shortnose sturgeon in the James River by Balazik (2017), the historic distribution of shortnose sturgeon in Virginia had not changed substantially since the issuance of the 2010 biological assessment of shortnose sturgeon. Shortnose sturgeon as amphidromous are known to inhabit the lower salinity reaches of their natal estuary; however, they can make coastal movements between watersheds (Dadswell* et al. 2013). While the current paradigm is that shortnose sturgeon stray less often than the congeneric Atlantic sturgeon, there is recent evidence of straying and recolonization from adjacent rivers (Balazik 2017; King et al. 2014). The shortnose sturgeon captured from the James River in 2016 is hypothesized to have been a colonizing or roaming fish from the Potomac River (about 120 km away), or the Delaware River (about 340 km away), that entered the system through the Chesapeake and Delaware Canal (Balazik 2017). Historically there have* been observations within the Chesapeake Bay in the Potomac River, including telemetry tagged fish. There is little evidence for spawning shortnose sturgeon populations within the Chesapeake Bay (Kynard et al. 2016). Kynard et al. (2016),

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 6 of 26 reviewing previous research concerning the capture of three late-stage females in the Potomac River including one tagged female which swam a one-step spawning migration to spawning habitat in Washington, D.C., indicated the potential for spawning and the possibility of a natal remnant population or ongoing colonization by Delaware River adults. Fewer than 10 have been observed in the lower Susquehan~a River (Kynard et al. 2016). No early life stages or young shortnose sturgeon have been observed in Virginia (Kynard et al. 2016). No critical habitat has been designated for the shortnose sturgeon (NOAA 201 Bc, NOAA 2018d). Kynard et al. (2016) reviewed research and literature available on the shortnose sturgeon and describes habitat requirements, foraging habitat, and diet by life stage in detail. The following summarizes the habitat features and requirements as presented by Kynard et al. (2016), which drew on and cited several other researchers. Shortnose sturgeon in the southern part of their range forage mostly at the freshwater-salt water interface or in salt water which is still considered to be an amphidromous life history characteristic. The total length of river/estuary used as their horne range is highly variable based on latitude in the sense that southern populations of shortnose sturgeon niust travel further considering the width of the coastal plain to find suitable rocky or rough, clay bits on the river bottom for spawning. Shortnose 'sturgeon in the Potomac River utilized a larger range of habitats in the spring and fall compared to winter and summer periods. Early life stage Atlantic and shortnose sturgeon are restricted to freshwater habitats. With increasing age, Atlantic sturgeon

  • move downstream to a more saline habitat, while the shortnose sturgeon larvae and juveniles remain in the freshwater-salt water interface for a longer duration. The current knowledge base for larvae and Age-0 shortnose sturgeon foraging habitat is relatively unknown, especially in the mid-Atlantic. It is well documented in other waters that juveniles (Age 1 +) and adults forage over sand and sand-mud habitats. Riverine habitats utilized by juveniles and adults vary from sandy to hard-mud and water depth varies from channel to shoals.

Early life stages of shortnose sturgeon disperse at variable rates and timings that may be correlated with latitude. Shortnose sturgeon in the northeast disperse as larvae, southern populations begin dispersal as free embryos and continue as larvae while shortnose sturgeon in the Savannah River continued a slow dispersal for months. The highly variable nature of the dispersal of early life stages of shortnose sturgeon may be linked to distributions of forage material. Yearling movements are not very well understood given the lack of telemetered fish studied. The timing of adult spawning migration is highly flexible and likely depends on the fish's reproductive status, distance from the spawning site and age. Shortnose sturgeon at all life stages appear to follow the channel during any upstream or downstream migrations. The most suitable spawning habitat is considered to be the most

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 7 of 26 upstream river reach used by shortnose sturgeon. Shortnose sturgeon early life stages also are very intolerant to salinities of 5-10 ppt until they are about 300 days of age. Shortnose sturgeon are known to utilize refuge seasonally in a concentrated range within their natal river. In mid-Atlantic and southern rivers, the most severe conditions that pose threats to survival for shortnose sturgeon are the summer months where the fish will retreat to areas with more moderate temperatures and higher dissolved oxygen levels. Table E3.7-4 Federally and State Listed Threatened and Endangered Species in Surry, James City, York, and Isle of Wright Counties (addition) (VDGIF 2018) E3.7.8.5 Essential Fish Habitat (replacement) The essential fish habitat (EFH) mapper provided by NOAA provides spatial and descriptive representation of EFH (https://www.fisheries.noaa.gov/resource/map/essential-fish-habitat-mapper). NOAA notes that the graphic representations are based on text descriptions, which are the most authoritative information available for identification of EFH. Therefore, it is important that the user verify any graphic representations from the EFH mapper with the descriptive text and literature. Table E3.7-5 presents the results of the EFH mapper and literature review. No habitat areas of particular concern (HAPCs) or EFH areas protected from fishing are located on or adjacent to the project site (NOAA. 2018e).

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 8 of 26 Table E3.7-5 Essential Fish Habitat in the James River near Surry Power Station (additions) The "EFH Mapper column represents the designation from the NOAA online mapping tool. The "Lit Review" column represents the designation supported by Dominion Energy Environmental Services' literature review (E = Eggs, L = Larvae, J = Juvenile, A = Adult). Species Latin Name Atlantic butterfish Peprilus triacanthus Atlantic herring<aJ C/upea harengus Black $Sa bass Centropristis striata Bluefish Pomatomus sa/tatrix Clearnose skate<aJ Raja eglanteria Little skate<aJ Leucoraja erinacea Red hake Urophycis chuss Sandbar shark<bJ Carcharhinus p/umbeus Scup Stenotomus chrysops EFH Mapper J,A J,A J,A J,A J,A A E, L, J,A Summer flounder Paralichthys dentatus L, J, A Winter skate<aJ Leucoraja ocel/ata A Lit Review J,A J L, J,A ____ Windowpane _flounder __________________________________ Scophthalmus _ aquosus ---------------------------------------------------------~-----------------------------------------------J, __ A ______________ _ (NOAA 201 Be; NOAA 201 Bf; NOAA 201 Bg) a) EFH designation near SPS was removed for these species by the New England Fishery Management Council & National Marine Fisheries Service Omnibus Amendment 2 (NOAA 201 Bh)_ The Mid-Atlantic Council is working collaboratively with the New England Fishery Management Council (Mid-Atlantic Fishery Management Council 2019)_ b) Noted as having adjacent EFH during EFH query conducted on November 16, 2016 (ER citation NOAA 2016c). See E4.6.6.4.2 for details regarding species-specific EFH characteristics. E4.6.1.4 Analysis (additions) Species-specific impingement of organisms at SPS was determined on a monthly basis. Per implementation guidelines for the 316(b) 2014 Rule, baseline impingement was determined based on a travelling screen mesh with a maximum opening of 0.56 inches. Because the travelling screen mesh at SPS is actually finer (1/8" x 1/2") than the baseline opening, the number of organisms representing "converts," those organisms that would be entrained under a baseline mesh size but were impinged at SPS, were also calculated. Identification of converts was based on morphometric measurements obtained during sampling. Converts represent a reduction in entrainment, and therefore were excluded from estimates of impingement mortality. Overall, converts accounted for an over 70% reduction in entrainment mortality. Initial survival of organisms was also determined during impingement sampling, and applied to the baseline estimates minus converts to develop estimates of impingement mortality. Where sample sizes

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 9 of 26 were low for a given taxa, representative information from the scientific literature was used to evaluate survival. Initial impingement survival was over 80% for most taxa. Bay anchovy accounted for the bulk (75%) of organisms collected during impingement sampling; however, most bay anchovy were classified as converts and excluded from impingement mortality estimates. Overall, finfish taxa experiencing the highest impingement mortality included Atlantic menhaden (32% of total IM), Atlantic croaker (22%), white perch (14%) and gizzard shad (13%). These four taxa represented over 80% of total impingement mortality. Blue crab dominated shellfish impingement mortality, accounting for 88% of all shellfish mortality. Species and life stage-specific entrainment of organisms at SPS were determined on a monthly basis. As with impingement, per implementation guidelines for the 316(b) 2014 Rule, baseline entrainment was determined based on a travelling screen mesh with a maximum opening of 0.56 inches. Because the travelling screen mesh at SPS is actually finer (1/8" x 1/2") than the baseline opening, the number of organisms representing "converts," those organisms that would be entrained under a baseline mesh size but were impinged at SPS, were also calculated and removed from the entrainment estimate. Identification of converts was based on morphometric measurements obtained during laboratory processing of samples. Non-viable eggs (i.e., those that would not hatch into fish) were excluded from all entrainment estimates. Because the entrainment study spanned two years, data was analyzed by year to examine annual variability. In both sampling years, shellfish accounted for the bulk (75% and 85% in years 1 and 2, respectively) of the total number of organisms collected. Gobies (Gobidae) accounted for 60% and 71 % of the finfish collected in years 1 and 2, respectively. Mud crab zoea (Panopeidae; 39%) and juvenile Tellin clams (35%) dominated shellfish collection in year

1. In year 2, fiddler crab zoea (39%) and mud crab zoea (Panopeidae; 33%) were dominant.

E4.6.6.4.2 Threatened, Endangered, and Protected Species and Essential Fish Habitat, Analysis, Operational Activities (additions) As noted previously (E3.7.8.1.14), there have been only two verified occurrences of shortnose sturgeon captured from the James River. Balazik (2017) provides a discussion on the historical documentation of shortnose sturgeon within the Chesapeake Bay drainage. He notes that there is debate regarding the potential for shortnose sturgeon in the Chesapeake Bay to be part of a remnant population or individuals colonizing the Chesapeake from the Delaware River via the Chesapeake and Delaware Canal. Based on extensive sampling in the James River conducted by a variety of researchers, often working with commercial fishermen, and the lack of documentation of any shortnose sturgeon in the river until 2016, Balazik (2017) concluded that the single specimen collected in 2016 was a transient or colonizing individual. No shortnose sturgeon have been collected in the historical or most recent entrainment or impingement studies conducted at SPS (E4.6.1.4). Historical and recent information available regarding the shortnose sturgeon in the James River reports it is extremely rare.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 10 of 26 Information on shortnose sturgeon habitat and foraging is presented in Section E3. 7.8.1.14. There is limited information available regarding the behavior, movements, or habits of the fish that could be applied to a species-specific assessment of potential impacts from SPS operations. The shortnose sturgeon has many attributes very similar to those for Atlantic sturgeon. The two species have a close lineage, are bottom-oriented, are morphologically similar, exhibit similar feeding behaviors, make spawning migrations, and spawn in similar habitats. The probable greatest distinction between the two is Atlantic sturgeon make coastal migrations, whereas the shortnose sturgeon tends to remain restricted to its natal river. No shortnose sturgeon have been collected in the historical or most recent entrainment or impingement studies conducted at SPS (E4.6.1.4). Based on the similarities between shortnose and Atlantic sturgeon, the susceptibility of shortnose sturgeon to entrainment and impingement would be expected to be very similar to that of Atlantic sturgeon. As detailed in NOAA's July 13, 2012, consultation response regarding potential effects of SPS operations on Atlantic sturgeon, spawning and the early life history stages of Atlantic sturgeon would be confined to freshwaters located upstream of SPS. Therefore, the probability of entrainment through the 1/8" x 1" travelling screens is not expected. While yearlings, subadult, and adult At[antic sturgeon would be present in the vicinity of SPS, various regulatory and mitigation measures are in place to prevent or reduce the probability of interactions. Historical and recent studies have demonstrated that the station's Ristroph travelling screens and debris return act to safely return impinged fish to the river away from the intakes. NOAA's assessment of the potential for Atlantic sturgeon to be impinged made use of shortnose sturgeon swimming ability information, noting juvenile and adult shortnose sturgeon can avoid impingement and entrainment at velocities as high as 3.0 fps. As noted in Section E3. 7.8.1. 7, the approach velocity at SPS trash racks is 0.98 fps, with a through-rack velocity of 1.12 fps. NOAA concluded the impingement or entrainment of Atlantic sturgeon is extremely unlikely to occur, and it is logical to carry this conclusion forward for shortnose sturgeon. Operations at SPS may also affect water quality, require dredging, cause sedimentation, or result in chemical spills, and so interact with shortnose sturgeon. NOAA addressed these potential impacts with regards to Atlantic sturgeon, and the conclusion reached should also apply to shortnose sturgeon due to the similarities between the species. Regarding water quality, the station's thermal plume has the potential to alter movements of shortnose sturgeon; however, mixing occurs rapidly in the near field around the outfall, and is largely contained to the surface. NOAA did not expect any significant impairment of normal behaviors due to the presence of the thermal plume. With regards to other pollutants, NOAA noted pollution limits are authorized by the station's VPDES permit, at levels at or below U.S. Environmental Protection Agency aquatic life criteria. NOAA did not address the potential effects of dredging, sedimentation, or chemical spills and these are discussed below.

\\ Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 11 of 26 Dredging in the lower reaches of rivers that include the salt-freshvyater transition zone likely has a great impact on reducing the recruitment of shortnose sturgeon, where present in abundance. This zone is a physical feature located at the heads of coastal plain estuaries that traps and retains sediment, detritus, zooplankton and early-life stages of fish, and is considered critical for anadromous fishes. The salt-freshwater transition zone is where Age-0 and juveniles rear throughout the species' range (Kynard et al. 2016). Dredging of the intake and discharge canals at SPS only occurs when necessary, every three to four years, and is conducted following consultation and permitting by the U.S. Army Corps of Engineers (USAGE) 404 program. Sedimentation is related to ground-disturbing activities, and no major activities are planned for SPS. SPS maintains and implements a stormwater pollution prevention plan (SWPPP) that identifies potential sources of pollution reasonably expected to affect the quality of stormwater, such as erosion, and identifies best management practices (BMPs) that will be used to prevent or reduce the pollutants in stormwater discharges. These practices, as they relate to erosion, include nonstructural preventative measures and source controls, as well as structural controls to prevent erosion or treat stormwater containing pollutants caused by erosion. In addition, any ground disturbance of 2,500 square feet or more requires a construction stormwater permit to be obtained from the Virginia Department of Environmental Quality (VDEQ). The construction stormwater permit specifies BMPs to reduce erosion caused by stormwater runoff, thereby minimizing the risk of pollution from soil erosion and sediment, and potentially from other pollutants that the stormwater may contact. Although no license renewal-related refurbishment or construction activities are planned, any such activities would continue to be managed in adherence to the SPS SWPPP. The dietary reliance of shortnose sturgeon in some rivers on bivalve mollusks makes them potentially susceptible to bioaccumulation of toxins from toxic algae blooms or other pollutants in the mollusks. Industrial practices at SPS that involve the use of chemicals are those activities typically associated with

painting, cleaning of parts/equipment, refueling of onsite vehicles/generators, fuel.oil and gasoline storage, and the storage and use of water treatment additives. The use and storage of chemicals at SPS are controlled in accordance with Dominion's fleet chemical control procedure and site-specific spill prevention plans. In addition, as presented in Section E2.2. 7, nonradioactive waste is managed in accordance with Dominion's waste management procedure, which contains preparedness and prevention control measures.

Dominion continuously monitors SPS's radiological effluents and maintains compliance with radiation protection standards. Dominion also monitors radioactivity levels annually by collecting samples of air, water, silt, shoreline sediment, milk, aquatic biota, and food products. The results for 2012-2015 did not detect radionuclides attributable to SPS. As in previous years, Dominion concluded that the operation of SPS has created no adverse environmental effects or health hazards.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 12 of 26 Dominion's new and significant information review addressed other Category 1 issues of aquatic resources and surface water quality and use. No new information was identified that would significantly impact water quality and aquatic resources. These issues concern the use of surface water for once-through cooling, discharge of metals in cooling water, discharge of biocides and sanitary wastes, the potential for water quality impacts from non-cooling water discharges, the potential for spills and minor chemical spills, sedimentation of surface waters, and related concerns. The new and significant information review concluded that compliance with current and future VPDES regulatory requirements and permit conditions, and implementation of the SWPPP and BMPs, will ensure continued protection of aquatic resources. Considering the above discussion on the potential for impacts to the shortnose sturgeon attributable to SPS operations and Dominion's adherence to permit conditions and regulatory requirements and commitment to comply with future permit conditions and regulatory requirements, the potential for SPS operations to adversely impact the shortnose sturgeon is minimized. Therefore, Dominion's conclusions that "the continued operation of the site would have no adverse effects to any federally protected or state-listed species... impacts from the proposed [subsequent license renewal] SLR on threatened, endangered, and protected species in the vicinity of SPS are not likely to affect federally protected or listed species and EFH," is also applicable to the shortnose sturgeon. Impacts to Designated Critical Habitat While Atlantic sturgeon from any of the DPSs could potentially occur in the James River, individuals from the Chesapeake Bay DPSs are most likely to be present (NMFS 2012). A key conservation objective for the Gulf of Maine, New York Bight, and Chesapeake Bay DPSs is increased abundance via successful reproduction and recruitment to the marine environment. NMf5S indicated the following physical features are essential to the conservation of the species:

1. A hard bottom substrate (e.g., rock, cobble, gravel, limestone, boulder) in low salinity waters for spawning and development of early life stages;
2. Aquatic habitat with a gradual downstream salinity gradient and soft substrate (e.g.,

sand, mud) downstream of spawning sites for juvenile foraging and development;

3. Water of appropriate depth (i.e., > 1.2 m) and absent physical barriers to passage (e.g.,

locks, dams) to allow unimpeded movements and provide staging, resting and holding areas;

4. Water temperature and oxygen, especially in the bottom meter of the water column, that will support all life stages (13-26°C for spawning habitat, no more than 30°C for juvenile rearing habitat, and 6 mg/I dissolved oxygen for juvenile rearing habitat).

The James River between Richmond and the mouth of the river is subjected to tidal motion and hence supports a tidal estuary. SPS is located in the transition region between the freshwater tidal river and the saline waters of the estuary proper. Cobham Bay just upstream of the Gravel

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 13 of 26 Neck Peninsula where SPS is located represents the approximate limit of salt water incursion, effectively dividing the James River into a tidally influenced freshwater river upstream (to the fall line at Richmond) and an estuary downstream. The upstream and downstream sides of the SPS site will have varying concentrations of ocean-derived salts, depending on river discharge. As discussed in E3.6.1, the salinity at the downstream side of the site is about 1 ppt at a river discharge of about 10,000 cfs. Salinity levels in the James River near SPS are not a physical feature essential for the eggs and early life stages of the Atlantic sturgeon (Item 1 above). Section E4.6.6.4.2 identifies the known spawning grounds and areas of the James River suitable for spawning and early life stages as being in the lower salinity portions of the river upstream from SPS. Known spawning grounds are approximately 52 miles upstream of the SPS low-level intake and a second area with seemingly suitable habitat is located approximately 25 miles upstream of the low-level. intake. Dominion considered SPS's potential to alter salinity gradients in its new and significant information review. The salinity gradient is governed by tidal influence rather than plant operations. The water withdrawn from the James River for SPS operations and returned through the once-through cooling system represents about 3% of the tidal flow in the James River in the vicinity of SPS (Section E3.6.3.1). The continued operation of SPS's once-through cooling system during the proposed SLR operating period is not anticipated to influence the salinity gradients. Thus, SPS operations would not impact the salinity level component of physical features 1 and 2 above. The features of hard bottom and soft bottom substrates mentioned in physical features 1 and 2 as well as the depth requirement of physical feature 3 could be affected by dredging and sedimentation. The 2018' Atlantic sturgeon benchmark stock assessment report (Section 7) identifies habitat loss and degradation, including that from dredging operations, as among the greatest threats to Atlantic sturgeon (ASMFC 2018). Section E3.7.3 describes the river bed in the vicinity of SPS as composed of soft mud, clay, sand, and pebbles, with no single bottom type predominating. Dredging takes place in the James River and the river is subject to sedimentation from anthropogenic operations along the length of the river as well as natural forces. SPS periodically dredges the intake channel. USAGE historically has dredged the main channel of the lower James River so ocean-going vessels can proceed upriver as far as Hopewell, approximately 50 river miles northwest of the SPS site, but this USAGE main channel dredging has no nexus with SPS operations. SPS dredging of the intake canal is conducted under Clean Water Act (CWA) Section 404 permits issued by the USAGE. USAGE is required to ensure that protected species and their habitat are not adversely affected by their federal action of issuing a permit allowing dredging and other Section 404 governed activities. Compliance with the 404 permit ensures that dredging activities do not contribute to water quality degradation or impact threatened and endangered species.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 14 of 26 Physical feature item 3 concerns barriers to passage. The 2017 Atlantic sturgeon benchmark stock assessment report identifies habitat loss and degradation, including that from dam construction, as among the greatest threats to Atlantic sturgeon (ASMFC 2018). There are no known or planned river control structures on the James River. In addition, as indicated in Section E4.6.6.4.1, the proposed action does not include license-related refurbishment activities and there would be no license renewal-related refurbishment impacts to threatened, endangered, and protected species or EFH. Physical feature item 4 concerns temperature, salinity, and dissolved oxygen conditions. Regarding the impact of SPS's thermal discharge on James River's conditions, as discussed in Section E.4.12.5 the cumulative trend in water temperature in the James River does not show an increase in maximum temperature and SPS's studies show rapid mixing of its thermal discharge with a drop of 1 to 2°F per 1,000 feet with the temperature rarely being greater than 5°F greater than ambient at 3,000 feet from the discharge point. Moreover, the James River is approximately 2.5 miles wide in the vicinity of the SPS site. Any increased temperature near the SPS site could be avoided by fish. As stated above, SPS operations do not influence salinity levels and gradients of the James River. As for dissolved oxygen conditions, Dominion considered this condition within its new and significant information review. Reductions in dissolved oxygen can be related to thermal discharges and eutrophication. SPS compliance history review for the past five years indicates no violations for concerns with thermal discharges. No plant operations or modifications that would alter the thermal discharge are planned for the proposed SLR operating period. The VDPES permit also includes limits and monitoring requirements for constituents implicated in eutrophication both for the sewage treatment plant outfall and the stormwater outfalls. Compliance with current and future VDPES regulatory requirements and permit conditions and implementation will minimize the potential for poor dissolved oxygen conditions resulting from SPS discharges. The 2017 Atlantic sturgeon benchmark stock assessment report (ASMFC 2018) identifies fishery and research bycatch in U.S. and Canadian waters, ship strikes, and habitat loss and degradation, including from dredging operations, shoreline modification, water pollution, and dam construction as among the greatest threats to Atlantic sturgeon. Of these, SPS has the greatest potential to contribute to habitat loss and degradation. The potential for dredging operations, shoreline modification, and water pollution to have detrimental effects to habitat is controlled and mitigated by regulatory processes and permits. There is no plan to construct a dam or barrier to Atlantic sturgeon movements in association with SPS. Beyond the physical features mentioned above that influence the quality of the Atlantic sturgeon's habitat, Dominion's new and significant information review addressed other Category 1 issues of aquatic resources and surface water quality and use. No new and significant information was identified that would impact water quality and aquatic resources or directly or indirectly impact the OCH. These issues concern the use of surface water for once-through

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 15 of 26 cooling, discharge of metals in cooling water, discharge of biocides and sanitary wastes, the potential for water quality impacts from non-cooling water discharges, the potential for spills and minor chemical spills, sedimentation of surface waters, and related concerns. SPS maintains and implements a SWPPP that identifies potential sources of pollution reasonably expected to affect the quality of stormwater, such as erosion, and identifies BMPs that will be used to prevent or reduce the pollutants in stormwater discharges (these practices, as they relate to erosion, include nonstructural preventative measures and source controls, as well as structural controls to prevent erosion or treat stormwater containing pollutants caused by erosion). In addition, any ground disturbance of 2,500 square feet or more requires a construction stormwater permit to be obtained from the VDEQ. The construction stormwater permit specifies BMPs to reduce erosion caused by stormwater runoff, thereby minimizing the risk of pollution from soil erosion and sediment, and potentially from other pollutants that the stormwater may contact. Although no license renewal-related refurbishment or construction activities are planned, any such activities would continue to be managed in adherence to the SPS SWPPP. Industrial practices at SPS that involve the use of chemicals are those activities typically associated with painting, cleaning of parts/equipment, refueling of onsite vehicles/generators, fuel oil and gasoline storage, and the storage and use of water treatment additives. The use and storage of chemicals at SPS are controlled in accordance with Dominion's fleet chemical control procedure and site-specific spill prevention plans. In addition, as presented in Section E2.2.7, nonradioactive waste is managed in accordance with Dominion's waste management procedure, which contains preparedness and prevention control measures. Dominion continuously monitors SPS's radiological effluents and maintains compliance with radiation protection standards. Dominion also monitors radioactivity levels annually by collecting samples of air, water, silt, shoreline sediment, milk, aquatic biota, and food products. The results for 2012-2015 did not detect radionuclides attributable to SPS. As in previous years, Dominion concluded that the operation of SPS has created no adverse environmental effects or health hazards. The new and significant information review concluded that compliance with current and future VPDES regulatory requirements and permit conditions, and implementation of the SWPPP and BMPs, will ensure continued protection of aquatic resources. Sedimentation is related to earth disturbing activities, and no major activities are planned for SPS. The impingement and entrainment of organisms that comprise the Atlantic sturgeon's diet could also _impact the quality of the OCH. The Atlantic sturgeon is primarily a benthic forager, feeding on worms, snails, shellfish, and bottom-dwelling fish (CBP 2018). As discussed in Section E3.7.8.5, impingement of fish and shellfish is mitigated at SPS by the existing modified travelling screens, which exclude organisms that cannot pass the 1/8" x 1/2" inch mesh. Organisms impinged on the screens are washed into a trough with flowing water and returned to the James

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 16 of 26 River. The 2015-2016 impingement study conducted at SPS documented impingement of shellfish and finfish on the station's travelling screens. Grass shrimp of the genus Palaemonetes were the most commonly impinged shellfish, followed by mud crabs of the family Xanthoidea and blue crabs. Together these three taxa accounted for 82% of the shellfish impinged during the study. All three taxa are abundant throughout the Chesapeake Bay and its tidal rivers. (USFWS 1985; USFWS 1989), and potential food items for Atlantic sturgeon. The exoskeleton of hard-bodied shellfish enhances survival of shellfish impinged on travelling screens. Initial impingement survival was assessed as part of the 2015-2016 impingement study at SPS. Over 97% of grass shrimp and mud crabs were live and undamaged when removed from the screenwash return trough and examined, as were 67% of blue crab. Relatively few bottom-dwelling finfish were collected during the impingement study. Of the five finfish species comprising 95% of the total number of finfish impinged, only the Atlantic croaker (5% of the total) would be classified as a bottom-dwelling fish. Atlantic croaker is abundant throughout the Chesapeake Bay and its tidal rivers. In the 2015-2016 impingement study at SPS, 65% of impinged Atlantic croaker were classified as live and undamaged when examined. Given impinged shellfish and bottom dwelling finfish are returned to the James River in generally good condition following impingement at SPS, to the impact on Atlantic sturgeon food availability from impingement at SPS would be SMALL. Organisms that can pass the travelling screen mesh and are entrained to the station condenser system are eventually returned to the James River via the station discharge canal. The survival rates of organisms entrained at SPS are not known, but studies at other power stations have indicated survival can be substantial, especially for hard-bodied invertebrates. The 2015-2017 entrainment study conducted at SPS documented entrainment of shellfish and finfish. Most shellfish were free swimming zoea or juveniles, and most finfish were post-yolk sac larvae. Mud crabs (Panopeidae), fiddler crabs, and Tellin clams together comprised over 82% of the total number of shellfish entrained, and are potential prey items for Atlantic sturgeon. Naked/seaboard gobies and bay anchovy comprised over 81 % of the finfish entrained. While bay anchovy is a pelagic species that would be unlikely prey for Atlantic sturgeon, naked and seaboard gobies are bottom dwelling fishes that would be vulnerable as prey items. Due to their small size and fragile nature, entrainable organism survival was not assessed during the 2015-2017 entrainment study. Dominion is currently processing impingement and entrainment data required by CWA §316(b) that were collected 2015-2017, will address impingement and entrainment mortality of finfish and shellfish, and determine if there is a need for additional protective measures. Dominion currently operates SPS under a VPDES permit that places limits on heat rejection, and is based on the results of a CWA §316(a) demonstration study that made use of physical and biological data collected 1970-1976. The station's thermal discharge (condenser cooling water) exits SPS through the *discharge canal and increases water temperatures in a localized section of the James River in the immediate vicinity of the canal outlet. Dominion is in the initial stages of conducting studies to update the existing CWA §316(a) demonstration study. The current

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 17 of 26 studies will include hydrothermal modeling of the station's thermal impact on the James River, and a biothermal assessment of temperature conditions resulting from operations on representative important species. Atlantic sturgeon will be one of the representative important species considered. Effects of thermal discharge on fish and shellfish will also be examined as part of the §316(b) agency review. Considering SPS operations and Dominion's adherence to permit conditions and regulatory requirements and commitment to comply with future permit conditions and regulatory requirements, the potential for SPS operations to impact the physical features essential for Atlantic sturgeon habitat is minimized. Therefore, consistent with "the continued operation of the site would have no adverse effects to any federally protected or state-listed species... impacts from the proposed SLR on threatened, endangered, and protected species in the vicinity of SPS are not likely to affect federally protected or listed species and EFH," Dominion concludes that SPS operations under the proposed action are not likely to adversely modify the Atlantic sturgeon OCH. Impacts to Essential Fish Habitat The habitat conditions of the species listed in Table 3.7-5 are discussed below. Atlantic Butterfish Juveniles and adults form loose schools and are common in the mid-Atlantic during the summer. They occur in sheltered bays and estuaries all the way out to over 200 m depths. They are common in the salinity mixing zone of the James River, which would include near SPS (Cross et al. 1999). Juveniles are generally found over bottom depths between 10 and 280 meters where bottom temperatures are between 6.5 and 27°C and salinities are above 5. Adults are generally found over bottom depths between 10 and 250 meters where bottom temperatures are between 4.5 and 27.5°C and salinities are above 5 ppt (Mid-Atlantic Fishery Management Council 2011). Atlantic butterfish are considered to have EFH near SPS because that portion of the James River is a salinity mixing zone. Atlantic Herring Atlantic herring are unlikely to be found in the area surrounding SPS in any life stage. The EFH for this species is limited to high salinity areas (>25 ppt) of the Chesapeake Bay (New England Fishery Management Council and NMFS, 2016; Stevenson and Scott 2005). While some herring species are anadromous, traveling up coastal rivers to spawn, Atlantic herring are fully marine and migrate to coastal and offshore spawning grounds (Gulf of Maine Research Institute 2019). Atlantic herring are not considered to have EFH near SPS due to low salinity and the lack of marine habitat.

Change Notice 1 SPS SLRA Black Sea Bass Serial No.: 18-448 Docket Nos.: 50-280/281 Page 18 of 26 Juveniles are found in the estuaries in the summer and spring, while adults are found through October. Juvenile and adult black sea bass are usually found in association with structured bottom habitats, both natural and man-made, preferring sand and shell substrate. Generally, juvenile and adult black sea bass are found in Virginia coastal areas when water temperatures rise to warmer than 6°C with salinities greater than 18 ppt (Mid-Atlantic Fishery Management Council 1998a; Steimle et al. 1999a). These conditions are rare near SPS (Bradshaw and Kuo 1987). Black sea bass are not considered to have EFH near SPS due to low salinity. Bluefish Juvenile bluefish occur in mid-Atlantic estuaries from May through October; adults from April through October. Adults are highly migratory and distribution varies seasonally according to the size of the individuals comprising the schools. Adults generally prefer salinity greater than 25 ppt (Mid-Atlantic Fishery Management Council 1998b), but juveniles can tolerate down to 3 ppt and can be abundant in the James River (Fahay et al. 1999). Bluefish are considered to have EFH in the vicinity of SPS due to the salinity mixing zone. Clearnose Skate Clearnose skates are unlikely to be found in the area surrounding SPS in any life stage. The EFH for this species is limited to only high salinity areas (>25 ppt of the Chesapeake Bay (New England Fishery Management Council and NMFS 2016; Packer et al. 2003). Clearnose skates are not considered to have EFH in the vicinity of SPS due to low salinity. Little Skate EFH for the little skate includes the Chesapeake Bay mainstem for the adult life stage for high (>25 ppt) and mixed salinity (0.5 to 25 ppt) (New England Fishery Management Council and NMFS, 2016, Table 28 and Appendix A). Little skates are not considered to have EFH near SPS due to low salinity, and they are unlikely to be found in the area surrounding SPS in any life stage. Red Hake Red hake are unlikely to be found in the area surrounding SPS in any life stage. The EFH for this species is limited to high salinity areas (>25 ppt) of the Chesapeake Bay (Steimle et al., 1999b). Red hake are not considered to have EFH near SPS due to low salinity. Sandbar Shark Sandbar sharks are an important commercial species in the southeastern U.S., with documented severe decline of catch per unit effort (CPUE) in the Chesapeake Bay area, likely due to heavy fishing pressure and the species' slow maturation. Shallow coastal waters of the lower Chesapeake Bay are primary summer nurseries and are designated as EFH and habitat areas of particular concern (NOAA 2006). However, recent research has shown more specific

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 19 of 26 requirements of water temperatures of 17-28°C, salinity greater than 20.5 ppt, and depth greater than 5.5 m (Grubbs and Musick 2007). These conditions are rare near SPS (Bradshaw and Kuo 1987). Sandbar sharks are not considered to have EFH near SPS due to low salinity. Scup During the acceptance review of the application, NRC held conference calls with Dominion to obtain clarification on information associated with or supporting of the application. This species was identified by the NRC as occurring within the James River. Dominion searches of the NOAA EFH identified the EFH for the scup as extending into the Chesapeake Bay, but not into the James River. Scup are not considered to have EFH near SPS due to its range limit. Summer Flounder Summer flounder larvae are most abundant within 50 miles of shore at depths of 30 to 230 feet, most frequently from September to May. Juveniles use several estuarine habitats as nursery areas, including salt marsh creeks, seagrass beds, mudflats, and open bay areas in water temperatures greater than 2.5°C and salinities from 1 O to 30 ppt. Adults are found in shallow coastal and estuarine waters during warmer months. Summer flounder are considered to have EFH in the vicinity of SPS due to the salinity mixing zone and appropriate bottom substrate. Winter Skate Winter skates are unlikely to be found in the area surrounding SPS in any life stage. The EFH for this species is limited to high salinity areas (>25 ppt) of the Chesapeake Bay (Omnibus EFH Amendment 2). Winter skates are not considered to have EFH in the vicinity of SPS due to low salinity. Windowpane Flounder Based on New England Fishery Management Council and NMFS (2016, Sections 2.1.1.10 and 2.2.1.10) reviews of EFH and finalized by NMFS (83 FR 15240, April 9, 2018), the windowpane flounder would also be potentially found in the SPS vicinity. SPS is adjacent to potential EFH for the juvenile and adult life stages of windowpane flounder. Habitat conditions for juveniles include intertidal and sub-tidal benthic habitats in estuarine, coastal marine, and continental shelf waters from the Gulf of Maine to northern Florida, including mixed and high salinity zones in bays and estuaries, including the Chesapeake Bay. EFH for juvenile windowpane flounder is found on mud and sand substrates and extends from the intertidal zone to a maximum depth of 60 meters. Young-of-the-year juveniles prefer sand over mud. Habitat conditions for adults include intertidal and sub-tidal benthic habitats in estuarine, coastal marine, and continental shelf waters from the Gulf of Maine to Cape Hatteras, including mixed and high salinity zones in bays and estuaries, including the Chesapeake Bay. EFH for adult windowpane flounder is found on mud and sand substrates and extends from the intertidal zone to a maximum depth of 70 meters. (New England Fishery Management Council and NMFS 2016, Sections 2.1.1.10 and

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 20 of 26 2.2.1.10). Windowpane flounder are considered to have EFH in the vicinity of SPS due to the presence of appropriate benthic habitats and marginally appropriate salinity. The SPS vicinity does provide conditions important for Atlantic butterfish, bluefish, summer flounder, and windowpane flounder. Bluefish and summer flounder were collected in low numbers during the 2015 and 2016 impingement studies at SPS (IR-HDR 2018, Table 4.2). The entrainment sampling conducted in 2015, 2016, and 2017 did not document these species, with the exception of two juvenile summer flounders collected during the August 2015 to July 2016 sampling period. The EFH for these species focus on salinity, temperature, and substrate composition. In some cases, EFH information is only available for one or two of these environmental factors. As discussed above for the OCH of Atlantic sturgeon, Dominion considered SPS's potential to alter salinity gradients, substrate, and temperature trends. The salinity gradient is governed by tidal influence rather than plant operations, and SPS operations would not impact the salinity level. The river bed in the vicinity of SPS is composed of soft mud, clay, sand, and pebbles, with no single bottom type predominating. SPS periodically dredges the intake channel under a USACE 404 permit which would require any special conditions to protect EFHs in the dredge area. SPS's thermal effluent is governed by its VPDES permit and the thermal plume disperses rapidly in the James River, with a temperature rarely above 5°F more than ambient temperature at 3,000 feet from the discharge point. The width of the James River near SPS also allows fish to avoid the plume. The EFHs could also be impacted by sedimentation, chemical pollutants, and radiological effluents. As discussed for the OCH, SPS has programs and permits in place to address these water quality factors. SPS maintains and implements a SWPPP and a construction stormwater permit would be obtained from the VDEQ for any construction that would disturb more than 2,500 square feet. SPS also operates in accordance with the requirements contained in its spill prevention, control, and countermeasures (SPCC) plan to prevent and mitigate spills. SPS complies with radiological environmental standards, and annual sampling of environmental media indicates operation of SPS has created no adverse environmental effects or health hazards. EFHs can also be impacted by the pressures of impingement and entrainment of the species or prey species. SPS operates under its current VPDES permit which considers the cooling water intake system as interim best technology available for reducing impingement and entrainment and requires Dominion conduct impingement and entrainment studies. The overall impingement and entrainment impacts of the SPS cooling water system are discussed in Section E4.6.1, concluding the impact of impingement and entrainment from continued operation of SPS's cooling water system to be SMALL. Four bluefish and seven summer flounder were collected during the 2015 and 2016 impingement studies at SPS out of the total finfish collection of approximately 286,000. Two juvenile summer flounders were collected during the August 2015

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 21 of 26 to July 2016 entrainment sampling period out of a total finfish collection of approximately 61,300 (IR-HDR 2018, draft, Table 4.5). Because of continued compliance with VDEQ requirements, and the absence or relative rarity of the EFH species of interest, Dominion concludes that impacts from impingement and entrainment of aquatic organisms during the proposed SLR operating term would be SMALL. Although additional mitigation measures may be implemented in the future as a result of the requirements in the final 316(b) Rule, these measures would minimize the already existing SMALL impacts. SPS's adherence to its VDPES permit, USACE issued CWA Section 404 permits, as well as implementing BMPs and spill prevention measures will serve to prevent and minimize discharges to the James River that could significantly impact ambient conditions. No refurbishment activities are planned and any future modifications for CWA 316(b) compliance would consider impacts to aquatic communities and EFHs. SPS's compliance with current and future VPDES regulatory requirements and permit conditions, and implementation of the SWPPP and BMPs, will continue to minimize effects to the James River conditions, ensuring continued protection of aquatic resources and EFH. Therefore, consistent with discussions and analysis in the ER that conclude on page E4-44 "the continued operation of the site would have no adverse effects to any federally protected or state-listed species... impacts from the proposed SLR on threatened, endangered, and protected species in the vicinity of SPS are not likely to affect federally protected or listed species and EFH," Dominion concludes that SPS operations under the proposed action would have no adverse impact for the EFHs. E4.12.5 Cumulative Impacts, Ecological Resources, Aquatic (addition) The federally listed shortnose sturgeon would also not be adversely affected by SPS operations. SPS's ongoing programs to mitigate and control water quality (e.g., VPDES permit, CWA 404 permit, SWPPP, SPCC plan) would minimize the potential for impacts to both sturgeon species, including the designated critical habitat as well as EFHs adjacent to SPS.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 22 of 26 Table EG.1-1 Environmental Impacts Related to Subsequent License Renewal at SPS (addition) Threatened, endangered, and protected species and essential fish habitat [10 CFR 51.53(c)(3)(ii)(E)] E4.6.6 SMALL impact. No license renewal-related refurbishment or other license-renewal related construction activities have been identified. The continued operation of the site would have no adverse effects on any federally or state-listed species. SLR would have no effect on threatened, endangered, and protected species in the vicinity of SPS. Add: SPS operations under the proposed action are not likely to adversely modify the Atlantic sturgeon designated critical habitat. SPS operations under the proposed action would have no adverse impact on EFHs.

Change Notice 1 SPS SLRA References (additions) Serial No.: 18-448 Docket Nos.: 50-280/281 Page 23 of 26 82 FR 39160. Endangered and Threatened Species; Designation of Critical Habitat for the Endangered New York Bight, Chesapeake Bay, Carolina and South Atlantic Distinct Population Segments of Atlantic Sturgeon and the Threated Gulf of Maine Distinct Population Segment of Atlantic Sturgeon. Federal Register 82:39160-39274 (August 17, 2017). 83 FR 15240. Magnuson-Stevens Fishery Conservation and Management Act Provision; Fisheries of the Northeastern United States; Essential Fish Habitat. Federal Register 83: 15240-15285 (April 9, 2018).. ASMFC. 2018. 2017 Atlantic Sturgeon Benchmark Stock Assessment and Peer Review Report. October 18, 2017. Balazik, M.T., G.C. Garman, J.P. Van Eenennaam, J. Mohler and L. Curry Woods Ill. 2012. Empirical Evidence of Fall Spawning by Atlantic Sturgeon in the James River, Virginia. Transactions of the American Fisheries Society, g1:6, 1465-1471. October 1, 2012. Balazik, Matthew. 2017. First verified occurrence of the shortnose sturgeon (Acipenser brevirostrum) in the James River, Virginia. Fisheries Bulletin 115:196-200. February 2, 2017. Bay Journal. 2018. Young Atlantic Sturgeon Numbers Surge in the James River. December 3, 2018. Retrieved from /https://www.bayjournal.com/article/young_atlantic_sturgeon_numbers_surge_in_the_james_ri "ver> (accessed December 18, 2018). Bradshaw J.G. and Kuo A.Y. *1987. Salinity Distribution in the James Estuary. Special Report No. 292 in Applied Marine Science and Ocean Engineering. Virginia Institute of Marine Science; 110 p. CBP (Chesapeake Bay Program). 2018. Atlantic Sturgeon. Retrieved from <https://www.chesapeakebay.net/discover> (accessed December 2018). Cross J.N., C.A. Zetlin, P.L. Berrien, D.L. Johnson, and C. McBride. 1999. Essential fish habitat source document: Butterfish, Peprilus triacanthus, life history and habitat characteristics. NOAA Tech Memo NMFS NE 145; 42 p. Dadswell, M.J., G. Nau, and M.J.W. Stokesbury. 2013. First Verified Record for Shortnose Sturgeon, Acipenser brevirostrum Lesueur, 1818, in Minas Basin, Bay of Fundy, Nova Scotia, Canada. Proceedings of the Nova Scotian Institute of Science 47:273-279. Fahay M.P., P.L. Berrien, D.L. Johnson, and W.W. Morse. 1999. Essential Fish Habitat Source Document: Bluefish, Pomatomus saltatrix, Life History and Habitat Characteristics. NOAA Tech Memo NMFS NE 144; 68 p. Grubbs, R. D. and Musick, J. 2007. Spatial Delineation of Summer Nursery Areas for Juvenile Sandbar Sharks in Chesapeake Bay, Virginia. American Fisheries Society Symp*osium. 50. 63-

86.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 24 of 26 Gulf of Maine Research Institute. 2019. Herring Biology: Life Cycle. Retrieved from <http://www.gma.org/herring/biology/life_cycle/default.asp> (accessed: January 2, 2019). Hager, C. 2011. Final Report: Atlantic Sturgeon Review: Gather data on reproducing subpopulation on Atlantic Sturgeon in the James River. Jenkins, R. E. and N. M. Burkhead. 1993. Freshwater fishes of Virginia. American Fisheries Society, Bethesda, Maryland. King T. L., A.P. Henderson, B.E. Kynard, M.C. Kieffer, D.L. Peterson, A.W. Aunins, and B.L. Brown. 2014. A Nuclear DNA Perspective on Delineating Evolutionarily Significant Lineages in Polyploids: the Case of the Endangered Shortnose Sturgeon (Acipenser brevirostrum). PLoS ONE 9(8):e102784. August 28, 2014. Kynard, B., S. Bolden, M. Keiffer, M. Collins, H. Brundage, E.J. Hilton, M. Litvak, M.T. Kinnison, T. King and D. Peterson. 2016. Life History and Status of Shortnose Sturgeon (Acipenser brevirostrum Lesueur, 1818). Journal of Applied Ichthyology, 32:208-248. Mid-Atlantic Fishery Management Council. 1998a. Amendment 12 to the Summer Flounder, Scup, and Black Sea Bass Fishery Management Plan. Mid-Atlantic Fishery Management Council. 1998b. Amendment 1 to the Bluefish Fishery Management Plan. Mid-Atlantic Fishery Management Council. 2011. Amendment 11 to the Atlantic Mackerel, Squid, and Butterfish Fishery Management Plan. Mid-Atlantic Fishery Management Council. 2019. Fish Habitat. Retrieved from <http://www.mafmc.org/habitat/> (accessed January 9, 2019). New England Fishery Management Council and National Marine Fisheries Service. 2016. Omnibus Essential Fish Habitat Amendment 2. Final Environmental Impact Statement. Volume

2. EFH and HAPC Designation Alternatives and Environmental Impacts. December 2016.

NMFS (National Marine Fisheries Service). 2012. Biological Opinion of James River Federal Navigation Project: Tribell Shoal Channel to Richmond Harbor in Surry, James City, Prince George, Charles City, Henrico, and Chesterfield Counties and the Cities of Richmond and Hopewell, Virginia (FINER/2012/01183). September 24, 2012. NOAA (National Oceanic and Atmospheric Administration). 2006. Final Consolidated Atlantic Highly Migratory Species Fishery Management Plan. Department of Commerce, National Oceanic and Atmospheric Administration. NOAA 2018a. Greater Atlantic Fisheries Office Master ESA Species Table. September 17, 2018. Retrieved from <https://www.greateratlantic.fisheries.noaa.gov/protected/section7/listing/garfo_master_esa_sp ecies_table_-_shortnose_sturgeon_09172018.pdf> (accessed December 19, 2018). NOAA. 2018b. Shortnose Sturgeon. Retrieved from <https://www.fisheries.noaa.gov/species/shortnose-sturqeon> (accessed December 19, 2018).

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 25 of 26 NOAA. 2018c. Greater Atlantic Region, The ESA and Recovery of Shortnose Sturgeon. Retrieved from <https://www.greateratlantic.fisheries.noaa.gov/protected/snsturgeon/recovery/index.html> (accessed December 19, 2018). NOAA 2018d. Critical Habitat. Retrieved from <https://www.fisheries.noaa.gov/national/endangered-species-conservation/critical-habitat> (accessed December 19, 2018). NOAA. 2018e. Essential Fish Habitat (EFH) Mapper. Retrieved from <https://www.habitat.noaa.gov/protection/efh/efhmapper/#> (accessed November 15, 2018). NOAA. 2018f. Guide to Essential Fish Habitat Descriptions. Retrieved from <https://www. g reateratlantic. fisheries. noaa.gov/hcd/list. htm> ( accessed December 12, 2018). NOAA. 20189. Northeast Fisheries Science Center. Essential Fish Habitat (EFH) Source Documents: Life History and Habitat Characteristics. Retrieved from <https://www.nefsc.noaa.gov/nefsc/habitat/efh/> (accessed December 12, 2018). NOAA. 2018h. Magnuson-Stevens Fishery Conservation and Management Act Provisions; Fisheries of the Northeastern United States; Essential Fish Habitat. Final rule. 50 CFR Part 648. Packer D.S., C.A. Zetlin, and J.J. Vitaliano. 2003. Essential fish habitat source document: Clearnose skate, Raja eglanteria, life history and habitat characteristics. NOAA Tech Memo NMFS NE 174; 50 p. Steimle F.W., C.A. Zetlin, P.L. Berrien, and S. Chang. 1999a. Essential fish habitat source document: Black sea bass, Centropristis striata, life history and habitat characteristics. NOAA Tech Memo NMFS NE 143; 42 p. Steimle F.W., W.W. Morse, P.L Berrien, and D.L. Johson. 1999b. Essential fish habitat source document: Red Hake, Urophycis chuss, life history and habitat characteristics. NOAA Tech Memo NMFS NE 133; 34 p. Stevenson D.K. and M.L. Scott. 2005. Essential fish habitat source document: Atlantic herring, Clupea harengus, life history and habitat characteristics (2nd edition). NOAA Tech Memo NMFS NE 192; 84 p. USFWS (U.S. Fish and Wildlife Service). 1985. Species Profiles: Life Histories and Environmental Requirements of Coastal Fishes and Invertebrates (Gulf of Mexico) GRASS SHRIMP. Biological Report 82 (11.35) USFWS. 1989. Species Profiles: Life Histories and Environmental Requirements of Coastal Fishes and Invertebrates (Mid-Atlantic) BLUE CRAB. Biological Report 82 (11.100) VDGIF (Virginia Department of Game and Inland Fisheries). 2018. Special Status Fauna( Species in Virginia. May 7, 2018. Retrieved from <https://www.dgif.virginia.gov/wp-content/uploads/virginia-threatened-endangered-species.pdf> (accessed December 19, 2018).

Change Notice 1 SPS SLRA References (deletions) Serial No.: 18-448 Docket Nos.: 50-280/281 Page 26 of 26 NMFS. 2009. Final Amendment 1 to the 2006 Consolidated Atlantic Highly Migratory Species Fishery Management Plan, Essential Fish Habitat. National Oceanic and Atmospheric Administration, National Marine Fisheries Service, Office of Sustainable Fisheries, Highly Migratory Species Management Division. Silver Spring, MD. Public Document. NOAA. 2016c. EFH Location Query Report. Retrieved from <http://www. habitat. noaa.gov/protection/efh/efhmapper/index. html> ( accessed November 16, 2016).

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 NATIONAL MARINE FISHERIES SERVICE RESPONSE LETTER TO DOMINION ENERGY VIRGINIA'S LETTER REGARDING SPECIAL STATUS SPECIES AND HABITAT Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Jason E. Williams, Manager Generation Environmental Services Dominion Energy Services 5000 Dominion Boulevard Glen Allen, VA 23060 UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration NATIONAL MARINE FISHERIES SERVICE GREATER ATLANTIC REGIONAL FISHERIES OFFICE 55 Great Republic Drive Gloucester, MA 01930-2276 OCT - 4 2017 Re: Virginia Electric and Power Company - Surry Power Station Units 1 and 2 Subsequent License Renewal

Dear Mr. Williams:

The National Oceanic and Atmospheric Administration's National Marine Fisheries Service (NMFS) has received your letter, dated August 3, 2017, seeking assistance in assessing the effects that extending the license term for Surry Power Station Units 1 and 2 (SPS) may have on resources under our jurisdiction within the immediate environments of facility. The applicant (Dominion Energy Virginia) proposes to maintain current operations over the license renewal period at SPS. The renewed license would use existing plant facilities and transmission lines. In addition to continued operation during this renewed license period, an approximate 85-acre management area for material from maintenance dredging in the James River at SPS' water intakes is presently being evaluated for permitted use. You also indicated that, if needed, the construction of a new concrete storage pad (pad #5) at the independent spent fuel storage installation (ISFSI) will be the only ground-disturbing activity anticipated at the SPS site during the extended license period. In 2012, we completed consultation with the Nuclear Regulatory Commission (NRC) pursuant to section 7 of the Endangered Species Act (ESA) of 1973, as amended, regarding effects of operations of the facility pursuant to the existing license. A copy of that consultation is included here your reference. Below, we provide updated information on trust resources. Endangered Species Act Several species listed by us occur in the James River where the intake for SPS is located. Individuals from any of the five listed distinct population segments (DPSs) of Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus) occur in the James River and may be present in the action area. There are several references that post-date our 2012 letter that may help in assessing the impacts to Atlantic sturgeon in the James River (e.g., Balazik 2012; Balazik et al. 2012a, 2012b). Although listed sea turtle species occur seasonally in Chesapeake Bay and may be present near the confluence of the James River, none of these species occur in the James River near the SPS. Since our informal consultation in 2012, new information confirms that shortnose sturgeon (Acipenser brevirostrum) are at least occasionally present in Virginia waters of the Chesapeake Bay. On March 13, 2016, a shortnose sturgeon was captured in the freshwater portion of the

James River at river kilometer 48 (within the 6-mile radius of the SPS site). Genetic analysis confirmed the fish was a shortnose sturgeon (see Balazik 2017). Since records of historical occurrence of shortnose sturgeon were begun in the late 1800s, shortnose sturgeon have seemed to be rare in the upper Chesapeake Bay and nonexistent in the lower Chesapeake Bay. At this time, we consider this fish to be a transient individual and there is no evidence of a James River population of shortnose sturgeon. On August 17, 2017, we published the final rule (82 FR 39160) to designate critical habitat for the threatened Gulf of Maine DPS of Atlantic sturgeon, the endangered New York Bight DPS of Atlantic sturgeon, the endangered Chesapeake Bay DPS of Atlantic sturgeon, the endangered Carolina DPS of Atlantic sturgeon and the endangered South Atlantic DPS of Atlantic sturgeon pursuant to the ESA. We identified the James River from Boshers Dam downstream to where the main stem river discharges at its mouth into the Chesapeake Bay at Hampton Roads as part of the critical habitat for the Chesapeake Bay DPS of Atlantic sturgeon (Figure 1 ). The effective date of this final rule is September 18, 2017. More information on shortnose and Atlantic sturgeon and recently designated critical habitat is available on our website (http:/ /wv:w.nero.noaa.gov/protected/section7 /listing/index.html). ChHlpNke Bay Unll 5 James River Map 13 e !I,o

ii>
,Qo 4$:

_,,,,,_,,{' o i.. ll> 't ..................,..,ow ***-\\****-..;...... ~. \\.:..,, Legend ~ Crillcal Habitat ArH TH* rnaptluslntNAUlllltt.....,._ attlal Mlllal. CIWAI ........ of tht""' WID*l tN lfM.tl'ltN Ct*II NllllltAne: ...,._..._,........,..,.,......._ '*dlrntcactrc,,ill9'1W crilicall.........,.....,..... rdrf t. O'w Nt'fflMt *K:dplie,I. Figure 1: Atlantic Sturgeon Critical Habitat within the James River 2

Section 7 Consultation Under Section 7(a)(2} of the ESA, each Federal agency is require4 to in~ure that any action they authorize, fund~ or carry out is not likely tojeopardtze the continued existence of any endangered species or threatened species and is not likely to destroy or adversely modify any designated critical habitat. The renewal of the operating license for the SPS facility by the NRC would be a federal action reql;liring section 7 consultation. ,., r As noted in yourleitet, 'b' appioxim~tb.ssla9.re management area for material from maintenance dredging in the James River at S:PS' water intakes is presently being evaluated for permitted use. Your letter also describes, the co11struction pf a new concrete storage pad (pad #5) at the ISFSI during the extended license period, if needed. We recommend that the applicant undertake a complete analysis of the effects that dredging and construction-related ground disturbance will have on physical or biological features identified in the critical habitat designation. In addition, you should consider the effects to critical habitat from the stressors identified in the 2012 informal consultation (e.g., withdrawal of water, discharge of heated effluent, radiological impacts, non-routine and accidental events, etc.). In addition to considering effects to critical habitat addressed above, the consultation will need to consider effects to shortnose and Atlantic sturgeon. SPS cannot operate without the intake and discharge of cooling water. Specific issues of concern related to the license renewal application review include the impingement and entrainment of endangered shortnose sturgeon and Atlantic sturgeon. Based on new information that confirms that shortnose sturgeon occur in the James River, an evaluation of impacts that extending the license term µiay have on both sturgeon species should be conducted. As noted in 2012, the best ~vailable information at that time supported a conclusion that no impingement or entrainment of shortnose or Atlantic sturgeon is expected at SPS. Any new monitoring, as well as consideration of any proposed changes in operating conditions, or other information should be considered to assess whether this conclusion remains valid. In addition to impingemient and entrainment, all other issues that were consigered in the 2012 consultation will need to be re-evaluated based on the best available information for the. license renewal. These include:

  • Effects of entrainment and impingement on sturgeon and sturgeon prey
  • A description of the thermal plume
  • Effects of the thermal plume on sturgeon and sturgeon prey
  • Impacts to water quality resulting from pollutants discharged from the facility
  • Radiological impacts to sturgeon and sturgeon prey
  • Impactsofclirhate change on sturgeon*and sturgeon habitat in the action area
  • Envirorimental risks as'sociated with non-routine and accidental' events at the facility We look forward to working with NRC arid the applicant throughout the relicensing process as

environmental documentation is developed to identify and evaluate the potential impacts to species under NMFS' jurisdiction. Should you have any questions regarding these comments as they relate to ESA matters, please contact me at (978)282-8480 or Julie.Crocker@noaa.gov. Sincerely, Julia E. Crocker ESA Fish Recovery Coordinator File Code: Sec 7 Tech Assist NRC Surry Relicensing References Balazik, M., 2012. Life history analysis of James River Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus) with implications for management and recovery of the species (Doctoral dissertation). Balazik, M. 2017. First verified occurrence of the shortnose sturgeon (Acipenser brevirostrum) in the James River, Virginia. Fishery Bulletin, 115(2): 196-201. Balazik, M.T., G.C. Garman, J.P. Van Eenennaam, J. Mohler, and L.C. Woods III, L. 2012. Empirical evidence of fall spawning by Atlantic sturgeon in the James River, Virginia. Transactions of the American Fisheries Society, 141(6): 1465-1471. Balazik, M.T., K.J. Reine, A.J. Spells, C.A. Fredrickson, M.L. Fine, G.C. Garman, and S.P. Mclninch. 2012. The potential for vessel interactions with adult Atlantic sturgeon in the James River, Virginia. North American Journal of Fisheries Management; 32(6):1062-1069. Dadswell, M.J., B.D. Taubert, T.S. Squiers, D. Marchette, and J. Buckley. 1984. Synopsis of biological data on shortnose sturgeon, Acipenser brevirostrum LeSueur 1818. National Oceanic and Atmospheric Administration Technical Report NMFS 14, Washington, D.C. Department of Commerce, National Oceanic and Atmospheric Administration, National Marine Fisheries Service Kynard, B., D. Pugh, and T. Parker. 2005. Experimental studies to develop a bypass for shdrtnose sturgeon at Holyoke Dam. Final report to Holyoke Gas and Electric, Holyoke, MA. 4

Smith, T.I.J., E.K. Dingley, and D.E. Marchette. 1980. Induced spawning and culture of Atlantic sturgeon. The Progressive Fish-Culturist, 42(3):147-151. Smith, T. I. J., D. E. Marchette, and R. A. Smiley. 1982. Life history, ecology, culture and management of Atlantic sturgeon, Acipenser oxyrinchus oxyrinchus, Mitchill, in South Carolina: Final report to the United States Fish and Wildlife Service. South Carolina Wildlife and Marine Resources Department, Columbia, South Carolina.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket No.: 50-280/281 Page 1 of 6 VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY CZMA RESPONSE LETTER Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Matthew J. Strickler Secretary of Natural Resources COMMONWEALTH of VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY Street address: 1111 Hast Main Stteet, Suite 1400, Richmond, VA 23219 Mailing addre.vs: P.O. Box 1105, Richmond, Virginia 23218 www.deq.virginia.gov February 2, 2018 Pamela F. Faggert Chief Environmental Officer Senior Vice President Sustainability Dominion Energy Services, Inc. 5000 Dominion Boulevard Glen Allen, VA 23060 David K. PB}for Director (804) 698-4000 )-800-592-5482 RE:. Federal Consistency Certification for the VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal, U.S. Nuclear Regulatory Commission, Surry County, DEQ 17-121F

Dear Ms. Faggert:

The Commonwealth of Virginia has completed its review of the above-mentioned Federal Consistency Certification (FCC). The Department of Environmental Quality is responsible for coordinating Virginia's review of FCCs and responding to appropriate officials on behalf of the Commonwealth. This letter is in response to the FCC dated August 3, 2017 and received on August 11, 2017, submitted by Dominion Energy Services, Inc. on behalf of the Virginia Electric and Power Company. The following agencies and planning district commission participated in this review: Department of Environmental Quality (DEQ) Department of Health {VDH) Department of Conservation and Recreation (DCR) Department of Historic Resources (OHR) Department of Game and Inland Fisheries (DGIF) Virginia Institute of Marine Science (VIMS) Crater Planning District Commission (PDC) In addition, the Marine Resources Commission, Surry County and the Hampton Roads Planning District Commission were invited to comment on the proposal.

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F PROJECT DESCRIPTION The Virginia Electric and Power Company (applicant, Dominion, or VEPCO) is seeking approval from the U.S. Nuclear Regulatory Commission (NRC) to renew the operating licenses for Surry Power Station (SPS) Units 1 and 2 for an additional twenty years. SPS is located on the James River in Surry County, Virginia. Dominion expects to submit the renewal application to the NRC in the first quarter of 2019. For SPS Unit 1 the requested renewal would extend the license expiration date from May 25, 2032 to May 25, 2052. For SPS Unit 2 the requested renewal would extend the license expiration date from January 29, 2033 to January 29, 2053. The subsequent license renewal application also considers the impacts from the in-scope transmission lines which connect the generating units to the-transmission grid and supply power to the plant during outages, located entirely on the SPS site. The license renewal process does not include modifications to structures or land disturbing activities. However, SPS may require additional space to store spent fuel during the period of extended operations. This involves the potential construction of an additional concrete pad at the existing Independent Spent Fuel Storage Installation (ISFSI). The ISFSI is a dry storage facility for spent fuel that is removed from SPS Unit 1 and 2. The ISFSI is separately licensed from the SPS by the NRG. SPS is fueled by uranium dioxide in two nuclear reactors to produce steam to drive the turbines. Cooling water is withdrawn from the James River through an approximate 5, 700-foot channel dredged in the riverbed between the main river channel and the eastern shore of Gravel Neck Peninsula. Dredging occurs every three to four years to maintain a depth of approximately 13 feet. A dredge materials management area (DMMA) is being constructed approximately four miles from the $PS site for use as a spoils area for future maintenance dredging of the intake. The applicant has submitted a Federal Consistency Certification that finds the proposed action consistent with the enforceable policies of the Virginia Coastal Zone Management Program. FEDERAL CONSISTENCY PUBLIC PARTICIPATION In accordance with 15 CFR §930.2, the public was invited to participate in the review of the proposal. Public notice of the proposed action was published in the OEIR Program Newsletter and on the DEQ website from August 17, 2017 to September 14, 2017. No public comments were received in response to the notice. FEDERAL CONSISTENCY UNDER THE COASTAL ZONE MANAGEMENT ACT Pursuant to the Coastal Zone Management Act of 1972 (CZMA), as amended, and the federal consistency regulations implementing the CZMA (15 CFR, Part 930, Subpart D, Section 930.50 et seq.), projects receiving federal permits, licenses or approvals, which can affect Virginia's coastal uses or resources, must be constructed and operated in a manner which is consistent with the Virginia Coastal Zone Management (CZM) Program. The Virginia CZM Program is comprised of a network of programs administered by several agencies. In order to be consistent with the Virginia CZM 2

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Program, all the applicable permits and approvals listed under the enforceable policies of the Virginia CZM Program must be obtained prior to commencing the project. FEDERAL CONSISTENCY CONDITIONAL CONCURRENCE Based on our review of the consistency certification and the comments submitted by agencies administering the enforceable policies of the Virginia CZM Program, DEQ conditionally concurs that the proposal is consistent with the Virginia CZM Program provided all applicable permits and approvals are obtained and the conditions of the enforceable policies are adhered to as described below. DGIF has raised concerns related to the consistency of the project with the fisheries management enforceable policy of the Virginia CZM Program (refer to Item 5 of the Federal Consistency Analysis section, pages 8-10). If, prior to construction, the project should change significantly and any of the enforceable policies of the Virginia CZM. Program would be affected, pursuant to 15 CFR 930.66, the applicant must submit supplemental information to DEQ for review and approval. Other state approvals which may apply to this project are not included in this consistency concurrence. Therefore, the,applicant must ensure that this project is constructed and operated in accordance with all applicable federal, state and local laws and regulations. Conditions of Concurrence with the FCC The conditions of the Commonwealth's concurrence include the following authorizations under the Virginia CZM Program: DGIF input and concurrence on the intake technology and conditions implemented to minimize impacts to fisheries resources and incidental take of endangered species in accordance with Virginia Code §29.1-100 to §29.1-570. In accordance with the Federal Consistency Regulations 15 CFR Part 930, section 930.4, this conditional concu-rrence is based on the applicant obtaining the necessary authorizations prior to initiating project activities. If the requirements of section 930.4, sub-paragraphs (a)(1) through (a)(3) are not met, this conditional concurrence becomes an objection under 15 CFR Part 930, section 930.63. FEDERAL CONSISTENCY ANALYSIS According to information in the FCC, the proposed activity would have no effect on the following enforceable policies: dunes management and shoreline sanitation. With the exception of the fisheries management enforceable policy analysis, the resource agencies that are responsible for the administration of the enforceable policies of the Virginia CZM Program generally agree with findings of the FCC. The applicant must ensure that the proposed action is consistent with the aforementioned policies. The analysis which follows responds to the discussion of the enforceable policies of the 3

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Virginia CZM Program that apply to this project and review comments submitted by agencies that administer the enforceable policies.

1. Nonpoint Source Pollution Control. According to the FCC (page 9), the proposed license renewal does not include land disturbing activities or modifications to structures.

Should routine maintenance, renovation or infrastructure projects require ground disturbance, appropriate erosion and sediment control and stormwater best management practices (BMPs) will be in place. Dominion has s*ubmitted a notice of intent for a stormwater construction general permit for the construction and use of the DMMA during the current license term and all required permits will b~ obtained as necessary. The DMMA will also be in use during the proposed subsequent license renewal period. 1(a) Agency Jurisdiction. The DEQ Office of Stormwater Management within the Division of Water Permitting administers the nonpoint source pollution control enforceable policy through the Virginia Erosion and Sediment Control Law and Regulations {VESCL&R) (Virginia Code §62.1-44.15 et seq. and 9 VAC 25-840-30 et seq.) and the Virginia Stormwater Management Law and Regulations (VSWML&R) (Virginia Code §62.1-44.15 et seq. and 9 VAC 25-870-54 et seq.). In addition, DEQ is responsible for the issuance, denial, revocation, termination and enforcement of the Virginia Stormwater Management Program (VSMP) General Permit for Stormwater Discharges from Construction Activities related to municipal separate storm sewer systems (MS4s) and construction activities for the control of stormwater discharges from MS4s and land disturbing activities under the Virginia Stormwater Management Program. 1(b) Agency RecQmmendation. The applicant should consider the use of permeable paving for parking areas and walkways, where appropriate. Denuded areas should be promptly revegetated following construction work. 1(c) Requirements. Any future land disturbance on the site, including the construction of the DMMA, must adhere to the erosion and sediment control and stormwater management requirements. 1(c)(i) Erosion and Sediment Control. lffuture projects/maintenance on the site involve a land-disturbing activity of equal to or greater than 2,500 square feet in a Chesapeake Bay Preservation Area, the applicant is responsible for submitting a project-specific erosion and sediment control (ESC) plan to the locality for review and approval pursuant to the local ESC requirements. Depending on local requirements, the area of land disturbance requiring an ESC plan may be less. The ESC plan must be approved by the locality prior to any land-disturbing activity at the project site. All regulated land-disturbing activities associated with the project, including on and off site access roads, staging areas, borrow areas, stockpiles and soil intentionally transported from the project, must be covered by the project-specific ESC plan. Local ESC program requirements must be requested through the locality. 4

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F 1(c){ii) Stormwater Management Plan. Dependent on local requirements, a stormwater management (SWM) plan may be required. Local SWM program requirements must be requested through the locality. 1(c){iii) General Virginia Pollutant Discharge Elimination System (VPDES} Permit for Discharges of Stormwater from Construction Activities {VAR10). The operator or owner of a construction activity involving land disturbance*of equal to or greater than 1 acre is required to register for coverage under the General VPDES Permit for Discharges of Stormwater from Construction Activities and develop a project specific stormwater pollution prevention plan (SWPPP). The SWPPP must be prepared prior to submission of the registration statement for coverage under the general permit and the SWPPP must address water quality and quantity in accordance with the Virginia Stormwater Management Program (VSMP) Regulations. General information and registration forms for the General Permit are available at www.deq.virginia.gov/Programs/Water/StormwaterManagemenWSMPPermits/Constru ctionGeneraf Permit.aspx. 1(d) Conclusion. As designed, the project is consistent with the nonpoint source pollution control enforceable policy of the Virginia CZM Program as no land disturbance is proposed.

2. Air Pollution Control. According to the FCC (page 11 ), the SPS air emission sources are permitted under Title V of the Federal Clean Air Act by DEQ permit number PR050336 which has been administratively continued beyond its expiration date of May 17, 2017. Air emissions from SPS result from intermittent use and testing of auxiliary boilers and diesel generators.

2(a) Agency Jurisdiction. The DEQ program implements the federal Clean Air Act to provide a legally enforceable State Implementation Plan for the attainment and maintenance of the National Ambient Air Quality Standards. This program is administered by the State Air Pollution Control Board at DEQ (Virginia Code §10-1.1300 through §10.1-- , 1320). 2(b) Agency Finding. The DEQ Air Division states that the project site is located in an ozone (03) attainment area. DEQ PRO confirmed that Dominion holds a Title V permit for this site (PR050336). If there are any intended changes to the systems, a permit modification may be required. 2(c) Requirements. Dominion should be aware of the below air pollution control requirements that would apply to any future construction at the ISFSI or DMMA. 2(c)(i) Fugitive Dust. During construction, fugitive dust must be kept to a minimum by using control methods outlined in 9 VAC 5-50-60 et seq. of the Regulations for the Control and Abatement of Air Pollution. These precautions include, but are not limited to, the following: 5

VEPCO Surry Power Station Units 1 and 2. Subsequent License Renewal DEQ 17-121F Use, where possible, of water or chemicals for dust control; Installation and use of hoods, fans, and fabric filters to enclose and vent the handling of dusty materials; Covering of open equipment for conveying materials; and Prompt removal of spilled or tracked dirt or other materials from paved streets and removal of dried sediments resulting from soil erosion. 2(c)(ii) Open Burning. If construction activities include open burning or the use of special incineration devices, this activity must meet the requirements under 9 VAC 5-130-10 through 9 VAC 130-60 and 9 VAC 5-130-1 00 of the Regulations for open burning. In addition, the Regulations provide for, but do not require, the local adoption of a model ordinance concerning open burning. The applicant should contact local fire officials to determine what local requirements, if any, exist. 2(d) Recommendation. PRO recommends that all actions should operate with air pollution control practices that minimize emissions. Fugitive dust should be kept to a minimum. 2(e) Conclusion. The project, as proposed, is consistent with the air pollution control enforceable policy of the Virginia CZM Program.

3. Coastal lands Management. The FCC (page 12) states that Surry County implemented the Chesapeake Bay preservation-related regulation via Section 3.1400 of its zoning ordinance. The proposed license renewal does not include land-disturbing activities. However, SPS may require additional space to store spent fuel during the period of extended operations. This would involve the potential construction of an additional concrete pad at the existing ISFSI.

3(a) Agency Jurisdiction. The DEQ Office of Local Government Programs (OLGP) administers the coastal lands management enforceable policy of the Virginia CZM Program which is governed by the Chesapeake Bay Preservation Act (Bay Act) (Virginia Code §62.1-44.15 et seq.) and Chesapeake Bay Preservation Area Designation and Management Regulations (Regulations) (9 VAC 25-830-10 et seq.). 3(b) Agency Findings. DEQ-OLGP notes that in Surry County, the areas protected by the Chesapeake Bay Preservation Act, as locally implemented, require conformance with performance criteria. These areas include Resource Protection Areas (RPAs) and Resource Management Areas (RMAs) as designated by the local government. RPAs include tidal wetlands, certain non-tidal wetlands and tidal shores. RPAs also include a 100-foot vegetated buffer area located adjacent to and landward of these features and along both sides of any water body with perennial flow. RMAs, which require less stringent performance criteria than RPAs, consist of all remaining areas within Surry County that are located within the James River Watershed. 6

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F The proposed license renewal does not include additional construction outside of the SPS site. However, during the period of extended operations, space may be required for storage of spent fuel, which would entail construction of an additional concrete pad at the existing ISFSI. The ISFSI is co-located on the SPS site and is also operated by Dominion Energy Virginia under a general license pursuant to NRC regulations. Although no RPA impacts are anticipated from the potential construction of an additional concrete pad, the ISFSI site is located within the County's designated Resource Management Area. 3(c) Requirements. The construction at the ISFSI site must be consistent with the general performance criteria provisions of 9VAC25-830-130 of the Regulations. This would include disturbing no more land than necessary to provide for the proposed use, minimizing impervious cover, and preserving indigenous vegetation to the maximum extent practicable consistent with the proposed use. In addition, all land disturbing activity exceeding 2,500 square feet must comply with the requirements of the Virginia Erosion and Sediment Control Handbook, Third Edition, 1992. Stormwater management criteria consistent with the water quality protection provisions of the Virginia Stormwater Management Regulations, 9VAC25-870-51 and 9 VAC25-870-103, shall be satisfied. These provisions require that localities subject to the Chesapeake Bay Preservation Act implement specified technical and administrative criteria from the VSMP regulations for Chesapeake Bay Preservation Act land-disturbing activities. Such activities include land disturbance equal to or greater than 2,500 square feet of land disturbance and less than one acre in designated Chesapeake Bay Preservation Areas. 3(d) Conclusion. Provided any construction at the ISFSI adheres to the above criteria, the proposed activity would be consistent with the Chesapeake Bay Preservation Area Designation and Management Regulations and the coastal lands management enforceable policy of the Virginia CZM Program.

4. Wetlands Management. According to the FCC (page 8), the proposed subsequent license renewal does not include land-disturbing activities or construction that will impact wetlands. The SPS holds a VMRC permit #2016-0710 for the maintenance dredging of the intake channel.

4(a) Agency Jurisdiction. The wetlands management enforceable policy is administered by the Virginia Marine Resources Commission (tidal wetlands) (Virginia Code 28.2-1301 through 28.2-1320) and the Department of Environmental Quality through the Virginia Water Protection Permit (VWP) program (tidal and non-tidal, wetlands) (Virginia Code §62.1-44.15:20 and Water Quality Certification pursuant to Section 401 of the Clean Water Act). 7

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F 4(b) Agency Findings. The DEQ Piedmont Regional Office (PRO) noted that if future development during the license term were to impact wetlands and streams, a DEQ VWP permit would be required. The Virginia Marine Resources Commission (VMRC) did not comment on the proposal. 4(c) Agency Recommendation. DEQ PRO recommends that all construction activities avoid wetlands to the maximum extent possible. 4(d) Agency Requirement. If impacts to wetlands or surface waters will occur during the new license term, the applicant must submit a Joint Permit Application (JPA) to obtain a VWP permit as necessary. 4(e) Conclusion. Provided a JPA is submitted and a VWP Permit is obtained, as necessary, the project will be consistent with the wetlands management enforceable policy of the Virginia CZM Program.

5. fisheries Management. According to the FCC (page 6), the permit for the process and stormwater discharge from the SPS facility (VA0004090) contains thermal limitations that are protective of indigenous shellfish, finfish, and wildlife in the James River. The Virginia Pollutant Discharge Elimination System (VPDES) program also addresses the Clean Water Act 316(b} regulations related to the impingement and entrainment impacts of cooling water intake structures. Environmental studies are currently underway to determine whether current operational methods to prevent entrainment are sufficient to meet the new 316(b) requirements. DEQ will make the compliance determination and modifications of the intake and/or cooling structures could be required in future. Dominion will continue to comply with the VPDES permit for the SPS during the proposed subsequent license renewal period.

5(a) Agency Jurisdiction. The fisheries management enforceable policy is administered by the Department of Game and Inland Fisheries (Virginia Code 29.1-100 to 29.1-570) and Virginia Marine Resources Commission {Virginia Code 28.2-200 to 28.2-713) which have management authority for the conservation and enhancement of finfish and shellfish resources in the Commonwealth. 5(b} Agency Findings. 5(b)(i) Virginia Department of Game and Inland Fisheries. The DGIF submitted significant comments on the proposal, which are summarized below. Refer to the attached email (Ewing/Howard, 10/6/17) for complete comments. 5(b)(i)(a) Atlantic Sturgeon. Since SPS was first licensed and began operation, the Atlantic Sturgeon has been federally-listed as an endangered species and the James River has been designated a Threatened and Endangered Species Water due to presence of Atlantic sturgeon. These fish are found in the river year-round, and are known to engage in both spring and fall migration and spawning in this 8

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17~121F reach of the river. These fish also are known to congregate in the James River from Hog Island downstream. The consistency certification states that with relicensing and continued operation of SPS, "aquatic organisms would continue to be impinged and entrained at the intake structure, but these impacts were determined to be small." DGIF is concerned about impingement and entrainment of aquatic species, including the federally-listed endangered Atlantic sturgeon and other anadromous fishes. In addition, DGIF is concerned about potential impacts of the cooling water discharge upon Atlantic sturgeon and other anadromous fishes. Furthermore, DGIF understands that it is necessary for the applicant to periodically dredge the canal that diverts water from the James River to the cooling water intake, which may impact sturgeon. DGIF notes that the NRC may consult with the U.S. Fish and Wildlife Service (FWS) to address potential impacts of this project on Atlantic sturgeon, and that FWS has expressed interest in DGIF's involvement in that process. DGIF anticipates mutual agreement among the agencies regarding any measures that may be appropriate. However, until such issues are resolved, DGIF cannot determine the likely impacts of relicensing and continued operations on these fishery resources. 5(b)(i)(b) Anadromous Fish. The affected reach of the James River, and lawnes Creek, have been designated Anadromous Fish Use Areas due to the presence of alewife herring, blueback herring, American shad, striped bass, yellow perch, and hickory shad. S(b)(ii) Virginia Marine Resources Commission. The VMRC did not comment on the proposal. 5{b}(iii) VDH Division of Shellfish Sanitation. VDH found that the project is located in or adjacent to approved shellfish growing waters. However, the activity, as described, will not require a change in classification. 5(b)(iv) Virginia Institute of Marine Science. VIMS had no comment on the FCC. 5(c) DGIF Recommendations. To protect resident aquatic species including federally Endangered Atlantic sturgeon and other anadromous fishes from impingement and entrainment, DGIF recommends that the applicant consider the redesign or retrofitting of the cooling water intake on the James River to take advantage of currently best technology available (BTA). Measures to protect the Atlantic sturgeon and other species could include intake screen mesh or design, intake velocity restrictions, or time-of-year restrictions on certain dredging or instream construction activities. DGIF requests the opportunity to participate in discussions between the NRC, FWS, and Dominion regarding the potential impacts of this project on the Atlantic sturgeon, and believe such consultation may offer the best path toward determination of appropriate measures, if any, that are needed to ensure continued protection of Atlantic 9

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F sturgeon and other resident aquatic species. DGIF also recommends that NOAA Fisheries Service be included in these discussions, as a cognizant federal agency. 5(d) Conclusion. At this time, DGIF cannot determine the likely impacts of relicensing and continued operations of the facility on fishery resources. Further coordination with and approval from DGIF on the methods in place to protect the Atlantic sturgeon and other species from impingement/entrainment at the intake structures is necessary in order for the project to be consistent with the fisheries management enforceable policy of the CZM Program (see Federal Consistency Conditional Concurrence, page 3).

6. Subaqueous lands Management. According to the FCC (page.7), Dominion holds a permit from VMRC (#2016-0710) for encroachment in, on, or over state-owned subaqueous lands to allow for the dredging of the cooling water intake channel. The permit includes a limit of 150,000 cubic yards of sediment removal. The channel is dredged every three to four years. During the subsequent license renewal period, Dominion will continue to obtain the required subaqueous lands permit from VMRC.

6(a) Agency Jurisdiction. The management program for subaqueous lands establishes conditions for granting or denying permits to use state-owned bottomlands based on considerations of potential effects on marine and fisheries resources, tidal wetlands, adjacent or nearby properties, anticipated public and private benefits, and water quality standards established by the Department of Environmental Quality. The program is administered by the Virginia Marine Resources Commission (Virginia Code §28.2-1200 to §28.2-1213). 6(b) Agency' Findings. The VMRC did not comment on the FCC documentation. However, a report (attached) was obtained from VMRC's Habitat Management Permits and Applications webpage that indicated that VMRC reviewed application #20160710 and issued a VMRC subaqueous permit for the maintenance dredging of the SPS intake channel effective until July 26, 2021. 6(c) Conclusion. As designed, the project is consistent with the subaqueous lands management enforceable policy of the Virginia CZM Program.

7. Point Source Pollution Control. According to the FCC (page 10), the facility holds a VPDES permit VA0004090 for its process water and industrial stormwater discharges.

The permit administers compliance with the Clean Water Act 316(a) and (b) requirements which address water intake and thermal discharges. Dominion will obtain a General VPDES Permit for Discharges of Stormwater Associated with Industrial Activity (VAR05) permit for the DMMA. 7(a) Agency Jurisdiction. The point source program is administered by the State Water Control Board pursuant to Virginia Code §62.1-44.15. Point source pollution control is accomplished through the implementation of the National Pollutant Discharge Eliminati.on System (NPDES) permit program established pursuant to §402 of the federal Clean Water Act and administered in Virginia as the VPDES permit program. The Water Quality 10

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Certification requirements of §401 of the Clean Water Act of 1972 is administered under the Virginia Water Protection Permit program. 7(b) Agency Findings. PRO confirmed that Surry Power Station has two VPDES permits: a construction stormwater general permit number VAR106343 and the individual industrial VPDES permit number VA0004090. 7(c) Agency Requirement. Contact the VPDES Permit Manager (Emilee Adamson, 804-527-5072) to obtain a permit modification if changes to the outfalls are necessary. 7(d) Conclusion. As designed, the project is consistent with the point source pollution control enforceable policy of the Virginia CZM Program. ADDiTIONAL ENVIRONMENTAL CONSIDERATIONS In addition to the enforceable policies of the Virginia CZM Program, comments were also provided with respect to other applicable requirements and recommendations. The applicant must ensure that this project is constructed and operated in accordance with all applicable federal, state, and local laws and regulations.

1. Solid and Hazardous Waste Management.

1(a) Agency Jurisdiction. On behalf of the Virginia Waste Management Board, the DEQ Division of Land Protection and Revitalization is responsible for carrying out the mandates of the Virginia Waste Management Act (Virginia Code §10.1-1400 et seq.), as well as meeting Virginia's federal obligations under the Resource Conservation and Recovery Act and the Comprehensive Environmental Response Compensation Liability Act (CERCLA), commonly known as Superfund. The DEQ Division of Land Protection and Revitalization also administers those laws and regulations on behalf of the State Water Control Board governing Petroleum Storage Tanks (Virginia Code §62.1-44.34:8 et seq.), including Aboveground Storage Tanks (9VAC25-91 et seq.) and Underground Storage Tanks (9VAC25-580 et seq. and 9VAC25-580-370 et seq.), also known as 'Virginia Tank Regulations', and§ 62.1-44.34:14 et seq. which covers oil spills. Virginia: Virginia Waste Management Act, Virginia Code§ 10.1-1400 et seq. Virginia Solid Waste Management Regulations, 9 VAC 20-81 o {9 VAC 20-81-620 applies to asbestos-containing materials) Virginia Hazardous Waste Management Regulations, 9 VAC 20-60 o (9 VAC 20-60-261 applies to lead-based paints) Virginia Regulations for the Transportation of Hazardous Materials, 9 VAC 20-110. 11

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Federal: Resource Conservation and Recovery Act (RCRA), 42 U.S. Code sections 6901 et seq. U.S. Department of Transportation Rules for Transportation of Hazardous Materials, 49 Code of Federal Regulations, Part 107 Applicable rules contained in Title 40, Code of Federal Regulations. 1(b) Agency Findings. DEQ's Division of Land Protection and Revitalization (DLPR) conducted a 0.5-mile radius search of solid and hazardous waste databases for waste-related sites, including petroleum releases, in the project vicinity. Five sites were identified within the project area. Hazardous Waste/RCRA Facility: VAD000619502, Surry Power Station, 5570 Hog Island Rd, Surry, VA 23883, Small Quantity Generator (SQG) Petroleum Releases: PC#20104125, Gravel Neck Turbine Station, 5208 Hog Island Road, Surry, VA 23883. Release Date: 09/15/2009. Status: Closed. PC#19943824, Surry Power Plant, 5570 Hog Island Road, Surry, VA 23883. Release Date: 05/16/1994. Status: Closed. PC#19931478, Surry Power Plant, 5570 Hog Island Road, Surry, VA 23883. Release Date: 02/03/1993. Status: Closed. PC#19891209, Surry Power Plant, 5570 Hog Island Road, Surry, VA 23883. Release Date: 03/31/1989. Status: Closed. 1(c) Recommendation. DEQ encourages the implementation of pollution prevention principles, including the reduction, reuse, and recycling of all solid wastes generated. All generation of hazardous wastes should be minimized and handled appropriately. The project engineer or manager should contact the DEQ's Piedmont Regional Office Tanks Program (805-527-5020) for further information regarding the above identified petroleum release cases. Evaluate the location, nature, extent of the petroleum releases and the potential for the releases to have an impact on the project or any future land disturbing activities at the site. 1(d) Waste Management Requirements. Any soil or groundwater that is suspected of contamination or wastes that are generated during future construction-related activities must be tested and disposed of in accordance with applicable federal, state, and local laws and regulations. All construction waste, including excess soil, must be characterized in accordance with the Virginia Hazardous Waste Management 12

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Regulations prior to disposal at an appropriate facility. It is the generator's responsibility to determine if a solid waste meets the criteria of a hazardous waste and ensure it is managed appropriately.

2. Natural Heritage Resources.

2(a} Agency Jurisdiction. 2(a)(i) Natural Heritage Resources. The Virginia Department of Conservation and Recreation's (DCR) Division of Natural Heritage (DNH): DNH's mission is conserving Virginia's biodiversity through inventory, protection and stewardship. The Virginia Natural Area Preserves Act (Virginia Code §10.1-209 through 217), authorized OCR to maintain a statewide database for conservation planning and*project review, protect land for the conservation of biodiversity, and the protect and ecologically manage the natural heritage resources of Virginia (the habitats of rare, threatened and endangered species, significant natural communities, geologic sites, and other natural features). 2(a)(ii) Threatened and Endangered Plant and Insect Species. The Virginia Department of Agriculture and Consumer Services (VDACS): The Endangered Plant and Insect Species Act of 1979 (Virginia Code Chapter 39 §3.1-1020 through 1030) authorizes VDACS to conserve, protect and manage endangered and threatened species of plants and insects. Under a Memorandum of Agreement established between VDACS and the OCR, DCR represents VDACS in comments regarding potential impacts on state-listed threatened and endangered plant and insect species. 2(b) Agency Findings. 2(b){i) Natural Heritage Resources. According to the information currently in DCR-DNH's Biotics Data System {Biotics), the Atlantic sturgeon (Acipenser oxyrinchus, G3/S2/LE/LE} has been documented adjacent to the project site in the James River. This species is currently classified as endangered by the National Oceanic and Atmospheric Administration National Marine Fisheries Service (NOAA Fisheries) and by the DGIF. Refer to the attached memorandum dated September 13, 2017 for more details about this species. 2(b)(ii) State-listed Plant and Insect Species. OCR finds that the current activity will not affect any documented state-listed plant and insect species. 2(b)(iii) State Natural Area Preserves. There are no State Natural Area Preserves under DCR's jurisdiction in the project vicinity. 2(c) Recommendations. Due to the legal status of the Atlantic sturgeon, DCR recommends coordination with NOAA Fisheries, to ensure compliance with the Virginia Endangered Species Act (VA ST§§ 29.1-563-570). DCR supports studies to determine if modifications to the intake/cooling structures are necessary to reduce entrainment and impingement impacts (as mentioned in the FCC). 13

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Contact DCR-DNH to secure updated information on natural heritage resources if the scope of the project changes and/or six months has passed before it is utilized. New and updated information is continually added to the Biotics Data System.

3. Public Water Supply.

3(a) Agency Jurisdiction. The Virginia Department of Health (VDH), Office of Drinking Water (ODW) reviews projects for the potential to impact public drinking water sources (groundwater wells and surface water intakes). VDH administers both federal and state laws governing waterworks operation. 3(b) Agency Findings. VDH-ODW found the following public groundwater wells to be located within a 1,000-foot radius of the project site: PWSID Number City/County System Name Facilitv Name 3181800 SURRY SURRY POWER STATION WELL B INSIDE GATE 3181800 SURRY SURRY POWER STATION WELL EWAREHOUSE ROADW 3181800 SURRY SURRY POWER STATION WELL C HIGH LEVEL ROAD EAST 3181802 SURRY VA POWER WELL 1 CONSTRUCTION SITE The following surface water intakes are located within a 5-mile radius of the project site: PWSID Number 3700500 System Name NEWPORT NEWS, CITY OF Facility Name SKIFFES CREEK The project is not within the watershed of any public surface water intakes. 3(c) Requirement. Potential impacts to public water distribution systems or sanitary sewage collection systems must be verified by the local utility. 3(d) Agency Recommendations. Utilize Best Management Practices (BMPs) including erosion and sedimentation controls and spill prevention controls and countermeasures on the site. Properly manage materials while on the site and during transport to prevent impacts to nearby surface waters. Field-mark the wells within a 1,000-foot radius from the project site to protect them from accidental damage during any future construction activities.

4. Recreational Resources.

4(a) Agency Jurisdiction. The OCR Division of Planning and Recreational Resources provides policy and direction to the public and private sectors to improve the 14

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ'17-121F management of recreational resources (in addition to outdoor and open spaces), and addresses issues related to scenic rivers, highways and byways. 4(b) Agency Findings. The OCR Division of Planning and Recreational Resources found that the project is within a section of the James River that has scenic river designation. Dominion may contact Lynn Crump at 804-786-5054 or via email at Lynn.Crump@dcr.virginia.gov with any questions about this designation.

5. Historic Structures and Architectural Resources.

5(a) Agency Jurisdiction. The Virginia Department of Historic Resources (DHR) conducts reviews of both federal and state projects to determine their effect on historic properties. Under the federal process, DHR is the State Historic Preservation Office, and ensures that federal undertakings - including licenses, permits, or funding - comply with Section 106 of the National Historic Preservation Act of 1966 (NHPA), as amended, and its implementing regulation at 36 CFR Part 800. Section 106 requires federal agencies to consider the effects of federal projects on properties that are listed or eligible for listing on the National Register of Historic Places. For state projects or activities on state lands, DHR is afforded an opportunity to review and comment on (1) the demolition of state property; (2) major state projects requiring an EIR; (3) archaeological investigations on state-controlled land; (4) projects that involve a landmark listed in the Virginia Landmarks Register; (5) the sale or lease of surplus state property; (6) exploration and recovery of underwater historic properties; and (7) excavation or removal of archaeological or historic features from caves. See DH R's website for more information about applicable state and federal laws and how to submit an application for review: http://www.dhr.virginia.gov/StateStewardship/lndex.htm. 5(b) Agency Finding. OHR has been in direct consultation with the NRC regarding this project. 5(c) Requirement. The NRC should continue to coordinate directly with DHR, as necessary, pursuant to Section 106 of the National Historic Preservation Act (as amended) and its implementing regulations codified at 36 CFR Part 800 which require Federal agencies to consider the effects of their undertakings on historic properties.

6. Wildlife Resources and Protected Species.

6(a) Agency Jurisdiction. DGIF, as the Commonwealth's wildlife and freshwater fish management agency, exercises enforcement and regulatory jurisdiction over wildlife and freshwater fish, including state-or federally-listed endangered or threatened species, but excluding listed insects (Virginia Code Title 29.1). DGIF is a consulting agency under the U.S. Fish and Wildlife Coordination Act (16 U.S.C. sections 661 et seq.) and provides environmental analysis of projects or permit applications coordinated through DEQ and several other state and federal agencies. DGIF determines likely 15

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F impacts upon fish and wildlife resources and habitat, and recommends appropriate measures to avoid, reduce or compensate for those impacts. For more information, see the DGIF website at www.dgif.virginia.gov. 6(b) Agency Findings. DGIF documents the state-listed endangered peregrine falcon from the project area. At this time the DGIF does not believe that the project is likely to result in adverse impacts upon peregrine falcons. DGIF documents bald eagle nests, roosts, and the James River Bald Eagle Concentration Zone from the project area. Significant habitat alteration, location of water-dependent facilities within concentration zones and/or near nests, or other recreational and commercial activities may result in adverse impacts upon eagles. Colonial waterbird colonies are documented from the project area. 6(c) Recommendations. Note that the peregrine falcon is a species that may be encountered on the SPS site and understand that future site development could impact this species. Ensure that this project is consistent with state and federal guidelines for the protection of bald eagles. Coordinate as appropriate with the U.S. Fish and Wildlife Service (FWS) regarding possible impacts upon bald eagles or the need for a federal bald eagle incidental take permit. To protect colonial waterbird colonies documented from the project area and associated with upland development at SPS, DGIF recommends that any colonies located on site be mapped and that an undisturbed, naturally vegetated buffer of 500-feet be maintained around each colony. Any significant construction ?Ctivities within 0.25-mile of any colony should adhere to a time-of-year restriction from February 15 through June 15 of any year.

7. Local and Regional Participation. In accordance with CFR 930, Subpart A,§ 930.6(b) of the Federal Consistency Regulations, DEQ, on behalf of the state, is responsible for securing necessary review and comment from other state agencies, the public, regional government agencies, and local government agencies, in determining the Commonwealth's concurrence or objection to a federal consistency certification.

7(a) Regional Comments. The Crater Planning District Commission reviewed the FCC and found it to be in accordance with the PDC's environmental policy directives.

8. Pesticides and Herbicides. Should construction or maintenance require the use of pesticides or herbicides for landscape maintenance, these chemicals should be in accordance with the principles of integrated pest management. The least toxic pesticides that are effective in controlling the target species should be used. Contact the Depa,rtment of Agriculture and Consumer Services at (804) 786-3501 for more information.
9. Pollution Prevention. DEQ advocates that principles of pollution prevention and sustainability be used in all construction projects as well as in facility operations.

Effective siting, planning, and on-site Best Management Practices (BMPs) will help to 16

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F ensure that environmental impacts are minimized. However, pollution prevention and sustainability techniques also include decisions related to construction materials, design, and.operational procedures that will facilitate the reduction of wastes at.the source. 9(a) Recommendations. We have several pollution prevention recommendations that may be helpful in operating this facility: Consider development of an effective Environmental Management System (EMS). An effective EMS will ensure that the proposed facility is committed to complying with environmental regulations, reducing risk, minimizing environmental impacts, setting environmental goals, and achieving improvements in its environmental performance. DEQ offers EMS development assistance and recognizes facilities with effective Environmental Management Systems through its Virginia Environmental Excellence Program (VEEP). VEEP provides recognition, annual permit fee discounts, and the possibility for alternative compliance methods. Consider contractors' commitment to the environment when-choosing contractors. Specifications regarding raw materials and construction practices can be included in contract documents and requests for proposals. DEQ's Office of Pollution Prevention provides information and technical assistance relating to pollution prevention techniques and EMS. If interested, please contact Meghann Quinn, (804) 698-4021. REGULATORY AND COORDINATION NEEDS

1. Nonpoint Source Pollution Control. Contact the DEQ Office of Stormwater Management (Hannah Zegler, 804-698-4206) with questions regarding nonpoint source pollution control as it relates to any future land disturbing activities on the site.
2. Air Pollution Control. For more information related to air pollution control requirements, contact DEQ PRO (804-527-5020). Contact the Air Permit Manager (James Kyle, 804-527-5047) to discuss a Title V permit modification, as necessary, to accommodate any future system changes.
3. Solid and Hazardous Wastes. All solid waste, hazardous waste, and hazardous materials must be managed in accordance with all applicable federal, state, and local environmental regulations. Contact DEQ PRO (804-527-5020) for information on the location and availability of suitable waste management facilities in the project area or if free product, discolored soils, or other evidence of contaminated soils are encountered during future land-disturbing activities on the site.
4. Natural Heritage Resources. Contact DCR-DNH, Rene Hypes at (804) 371-2708, to secure updated information on natural heritage resources if the scope of the project 17

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F changes and/or six months passes before the project is implemented, since new and updated information is continually added to the Biotics Data System.

5. Potable and Sanitary Water Collection Systems. Potential impacts to public water distribution systems or sanitary sewage collection systems must be verified by the local utility. Contact the VDH-Office of Drinking Water with questions (804-864-7201 ).
6. Coastal Lands Management. Any future construction at the ISFSI site must be conducted in a manner that is consistent with the coastal lands management enforceable policy of the CZM Program as administere9 by DEQ pursuant to the Chesapeake Bay Preservation Act (Virginia Code 62.1-44.15 et seq.) and the Chesapeake Bay Preservation Area Designation and Management Regulations (9VAC25-830 et. seq.). For additional information contact Daniel Moore (804-698-4520).
7. Historic Resources. The NRC should continue to coordinate directly with OHR (Roger Kirchen, 804-482-6091) pursuant to Section 106 of the National Historic Preservation Act (as amended) and its implementing regulations codified at 36 CFR Part 800 which require Federal agencies to consider the effects of their undertakings on historic properties.
8. fisheries Management. Coordinate with DGIF {Amy Ewing, 804-367-2211) regarding its recommendation to retrofit the James River cooling water intake with best technology available (BTA) in order to protect the federally-listed endangered Atlantic sturgeon and other aquatic organisms.

Include DGIF and NOAA Fisheries Service (804-684-7382) in discussions with the NRC and FWS regarding the potential impacts of this project on the Atlantic sturgeon. Continue to coordinate with DGIF until a determination on the likely impacts of relicensing and continued operations of the facility can be made.

9. Wildlife and Protected Species. Coordinate as appropriate with the U.S. FWS (Troy Andersen, troy_andersen@fws.gov) regarding possible impacts upon bald eagles or the need for a federal bald eagle incidental take permit. Contact.DGIF, Amy Ewing at (804) 367-2211, with questions regarding its recommendations.
10. Point Source Pollution Control. Contact the VPDES Permit Manager (Emilee Adamson, 804-527-5072) if changes (additional outfalls) to the facility's existing VPDES permits become necessary.

Thank you for the opportunity to comment on the FCC submitted for the VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal project located in Surry County. Detailed comments of reviewing agencies are attached for your review., Please contact me at (804) 698-4204 or Janine Howard at (804) 698-4299 for clarification of these comments. 18

VEPCO Surry Power Station Units 1 and 2 Subsequent License Renewal DEQ 17-121F Sincerely, ~-- Bettina Rayfield, Program Manager Environmental Impact Review Ee: Robbie Rhur, DCR Amy Ewing, DGIF Susan Douglas, VDH Roger Kirchen, OHR Emily Hein, VIMS Tony Watkinson, VMRC Ben McFarlane, HRPDC Dennis Morris, Crater PDC Tyrone Franklin, Surry County Pamela Faggert, Dominion Oula Shehab-Dandan, Dominion Tony Banks, Dominion Tam Tran, NRG 19 --~-

Howard, Janine (DEQ) From: Ewing, Amy (DGIF) Sent: Friday, October 06, 2017 4:59 PM Howard, Janine (DEQ) To: Cc:

Subject:

Fernald, Ray (DGIF}; Oula K Shehab-Dandan; Greenlee, Bob {DGIF); Smith, Scott (DGIF) ESSLog# 38468_ 14-121 F _SurryPowerStationRelicensing_DGIF _AME20171006

Janine, We have reviewed the consistency determination for the subject project, relicensing of Surry Power Station (SPS) Units 1 and 2, located at Surry Power Station in Surry County, adjacent to our Hog Island Wildlife Management Area. We note that the applicant, Dominion Energy, has reached out to us for information about wildlife resources under our jurisdiction that are known from the project area, and that we have therefore copied them on this response to you.

Since SPS was licensed and began operation, Atlantic sturgeon, in addition to other wildlife native to VA, have been federally listed as an Endangered Species. Therefore, the James River has been designated a Threatened and Endangered Species Water due to presence of Atlantic sturgeon. These fish are known from the river year-round, and to engage in both spring and fall migration and spawning in this reach of the river. These fish also are known to congregate in the James River from Hog Island downstream. In addition, this stretch of the James River, and Lawnes Creek, have been designated Anadromous Fish Use Areas because of the prese~ce of alewife herring, blueback herring, American shad, striped bass, yellow perch, and hickory shad. The applicant states in their consistency determination that with relicensing and continued operation of SPS, "aquatic organisms would continue to be impinged and entrained at the intake structure, but these impacts were determined to be SMALL." To protect resident aquatic species including federally Endangered Atlantic sturgeon and other anadromous fishes from impingement and entrainment, we recommend that the applicant consider redesign/retrofitting of the cooling water intake on the James River to take advantage of currently best technology available (BT A). In addition, we are concerned about potential impacts of cooling water discharge upon Atlantic sturgeon. Furthermore, we understand that it is necessary for the applicant to periodically dredge the canal that diverts water from the James River to the cooling water intake, which activity also may impact sturgeon. We note that NRC may engage in consultation with the U.S. Fish and Wildlife Service to address potential impacts of this project on Atlantic sturgeon, and that USFWS has expressed interest in our input to that process. We gladly would participate in such discussions, and believe such consultation may offer the best path toward determination of appropriate measures, if any, that are needed to ensure continued protection of Atlantic sturgeon and other resident aquatic species. Such measures could include intake screen mesh or design, intake velocity restrictions, or time~of-year restrictions on certain dredging or instream construction activities. Though we would anticipate mutual agreement among the agencies regarding any measures that may be appropriate, until such issues are resolved, we cannot determine the likely impacts of relicensing and continued operations on these fishery resources, so we are unable to concur with the applicant's determination of consistency with the Fisheries Enforceable Policy of the CZMA. We also recommend that NOAA Fisheries Service be included in these discussions, as a cognizant federal agency. Regarding other fish and wildlife resources under our jurisdiction, we offer the following additional comments: (1) We recommend coordination with the USFWS regarding potential impacts upon federally Threatened northern long-eared bats associated with any tree removal associated with upland development on site. (2) We document state Endangered peregrine falcons from the project area. Based on the information we currently have, we do not believe this project is likely to result in adverse impacts upon peregrine falcons. However, we recommend the applicant consider this species as one that may be encountered onsite, especially as they could be impacted by future site development. (3) We document bald eagle nests, roosts, and the James River Bald Eagle Concentration Zone from the project area. Significant habitat alteration, location of water-dependent facilities within concentration zones and/or near nests, or other recreational and commercial activities may result in adverse impacts upon eagles. Therefore, we recommend that the applicant ensure that this project is consistent with state and federal guidelines for protection of bald eagles; and that they coordinate as appropriate with the U.S. Fish and Wildlife Service regarding possible impacts upon bald eagles or the need for a federal bald eagle incidental take permit. (4) We document colonial waterbird colonies from the project area. To best protect these resource associated with upland development at SPs*. we recommend that any colonies located on site be mapped and that an 1

undisturbed, naturally vegetated.buffer of 500ft be maintained around each colony. We recommend that any significant construction activities within 0.25 mile of any colony adhere to a time-of-year restriction from February 15 through June 15 of any year. (5) This project is located within 2 miles of a documented occurrence of a state or federal threatened or endangered plant or insect species and/or other Natural Heritage coordination species. Therefore, we recommend coordination with VDCR-DNH regarding the protection of these resources. Thank you for this opportunity to review this project; we look forward to resolving these issues through consultation with the appropriate federal and state agencies, as is indicated in the applicant's request for our input, so that we can then concur with the determination of federal consistency. Amy AM!J M. Ewing Evwirovwvte~ta./ Services Biologist/FWfS Progra.vn Ma.VI.ager Chair, Tea.vn WILD (Wol"k, IJI\\Vlova.te, Lead a.Vld Develop) 804-3G7-:Uj.j. ~ www.tJ.siF.vir9inio..9oy "Tl1at lal'ld is a coWll'VIU.l'lity is the basic con.cept of ecology, br.,.t that land is to be loved al'ld respected is an extensiol'l of et/.\\ics" Aldo Leopold. :J.'?48 2

DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF AIR PROGRAM COORDINATION ENVIRONMENTAL REVIEW COMMENTS APPLICABLE TO AIR QUALITY TO: Janine L. Howard DEQ - OEIA PROJECT NUMBER: DEQ #17-121F PROJECT TYPE: D STATE EA/ EIR X FEDERAL EA/ EIS D sec X CONSISTENCY CERTIFICATION PROJECT TITLE: VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal PROJECT.SPONSOR: U.S. Nuclear Regulatory Commission PROJECT LOCATION: X OZONE ATTAINMENT/ AREA REGULATORY REQUIREMENTSMAY BE APPLICABLE TO: X 0 LICENCE RENEWAL OPERATION STATE AIR POLLUTION CONTROL BOARD REGULATIONS THAT MAY APPLY:

1. 0 9 VAC 5-40-5200 C & 9 VAC 5-40-5220 E-STAGE I
2. D 9 VAC 5-45-760 et seq. -Asphalt Paving operations
3. D 9 VAC 5-130 et seq. - Open Burning
4. D 9 VAC 5-50-60 et seq. Fugitive Dust Emissions
5. D 9 VAC 5-50-130 et seq. - Odorous Emissions; Applicable to _______ _
6. D 9 VAC 5-60-300 et seq. - Standards of Performance for Toxic Pollutants
7. 0 9 VAC 5-50-400 Subpart __, Standards of Performance for New Stationary Sources, designates standards of performance for the ________________ _
8. D 9 VAC 5-80-1100 et seq. of the regulations-Permits for Stationary Sources
9. D 9 VAC 5-80-1605 et seq. Of the regulations - Major or Modified Sources located in PSD areas. This rule may be applicable to the------------
10. D 9 VAC 5-80-2000 et seq. of the regulations-New and modified sources located in non-attainment areas
11. D 9 VAC 5-80-800 et seq. Of the regulations - State Operating Permits. This rule may be applicable to _____ ~--------------

COMMENTS SPECIFIC TO THE PROJECT: None. (Kotur S. Narasimhan) Office of Air Data Analysis DATE: September 20, 2017

Molly Joseph Ward Secretary of Natural Resources COMMONWEALTH of VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY Street address: 629 East Main Street, Richmond, Virginia 23219 Mailing address: P.O. Box 1105, Richmond, Virginia 23218 Fax: 804-698-4019-TDD (804) 698-4021 www.deq.virginia.gov MEMORANDUM TO: Janine Howard, DEQ Office of Environmental Impact Review FROM: Heather Mackey, DEQ Principal Environmental Planner DATE: Septemberll,2017 David K. Paylor Director (804) 698-4020 1-800-592-5482

SUBJECT:

DEQ #l 7-121F: USNRC VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal - Surry County We have reviewed the Federal Consistency Determination submittal for the proposed project and offer the following comments regarding consistency with the provisions of the Chesapeake Bay Preservation Area Designation and Management Regulations (Regulations): In Surry County, the areas protected by the Chesapeake Bay Preservation Act (CBPA), as locally implemented, require conformance with performance criteria. These areas include Resource Protection Areas (RP As) and Resource Management Areas (RMAs) as designated by the local government. RP As include tidal wetlands, certain non-tidal wetlands and tidal shores. RP As also include a 100-foot vegetated buffer area located adjacent to and landward of these features and along both sides of any water body with perennial flow. RMAs, which require less stringent performance criteria than RP As, consist of all remaining areas within Surry County that are located within the James River Watershed. The proposed project would extend the Nuclear Regulatory Commission (NRC) operating license expiration date for Surry Power Station (SPS) Unit 1 from May 25, 2032 to May 25, 2052, and for SPS Unit 2 from January 29, 2033 to January 29, 2053. The proposed license renewal does not include additional construction outside of the SPS site; however, during the period of extended operations space may be required for storage of spent fuel, which would entail construction of an additional concrete pad at the existing Independent Spent Fuel Storage Installation (ISFSI). The ISFSI is co-located on the SPS site and is also operated by Dominion Energy Virginia under a general license pursuant to NRC regulations. While the consistency determination is for an extension of the operations of the nuclear units only, the ISFSI is considered in the cumulative impacts of the Environmental Report supporting the SPS license renewal application.

Although no RP A impacts are anticipated from the potential construction of an additional concrete pad, the ISFSI site is located within the County's designated Resource Management Area. As such, the project must be consistent with the general performance criteria provisions of §9V AC25-830-130 of the Regulations. This would include disturbing no more land than necessary to provide for the proposed use, minimizing impervious cover, and preserving indigenous vegetation to the maximum extent practicable consistent with the proposed use. In addition, all land disturbing activity exceeding 2,500 square feet must comply with the requirements of the Virginia Erosion and Sediment Control Handbook, Third Edition, 1992. Finally, stormwater management criteria consistent with the water quality protection provisions of the Virginia Stormwater Management Regulations, §9V AC25-870-51 and 9 V AC25-870-l 03, shall be satisfied. These provisions require that localities subject to the Chesapeake Bay Preservation Act implement specified technical and administrative criteria from the VSMP regulations for Chesapeake Bay Preservation Act land-disturbing activities. Such activities include land disturbance equal to or greater than 2,500 square feet of land disturbance and less than one acre in designated Chesapeake Bay Preservation Areas. Provided the above conditions are met, the proposed activity would be.consistent with the Regulations and the Chesapeake Bay Preservation Act. 2

Howard, Janine (DEQ) From: Zegler, Hannah (DEQ) Sent: To: Wednesday, November 01, 201711:48 AM Howard, Janine (DEQ)

Subject:

RE: Dominion AS&S question AS&S don't cover power plants so this would go to the locality... your comment below are appropriate. From: Howard, Janine {DEQ) Sent: Wednesday, November 1, 2017 11:43 AM To: Zegler, Hannah (DEQ) <Hannah.Zegler@deg.virginia.gov>

Subject:

RE: Dominion AS&S question Hi Hannah, This project isn't related to construction or rebuild of a utility line. It has to do with renewal of the Nuclear Regulatory Commission (NRC) operating license for the Surry Power Plant. So, modifications to structures at the Surry facility are not proposed, however there is a possibility that during the course of the renewed license term (which would be in effect until 2053) some land-disturbing activities on the power plant site itself may occur (for instance, an addition or renovation to a structure may become necessary). I'm wondering if the below language that requires ESC and SWM plans to be sent to the locality is correct for this scenario or whether the annual standards and specs language is more appropriate. 1(c)(i) Erosion and Sediment Control. lffuture maintenance activities on the site involve a land-disturbing activity of equal to or greater than 2,500 square feet in a Chesapeake Bay Preservation Area, the applicant is responsible for submitting a project-specific erosion and sediment control (ESC) plan to the locality for review and approval pursuant to the local ESC requirements. Depending on local requirements, the area of land disturbance requiring an ESC plan may be less. The ESC plan must be approved by the locality prior to any land-disturbing activity at the project site. All regulated land-disturbing activities associated with the project, including on and off site access roads, staging areas, borrow areas, stockpiles and soil intentionally transported from the project, must be covered by the project-specific ESC plan. Local ESC program

  • requirements must be requested through the locality.

1(c)(ii) Stormwater Management Plan. Dependent on local requirements, a stormwater management (SWM) plan may be required. Local SWM program requirements must be requested through the locality. Thanks! ...*...............,,......,,.sS,',"W'**. *.w.,,u.*,,*,-*,*,'*" 8 w'"' 0 "'"""-"";*'******.'* From: Zegler, Hannah (DEQ) Sent: Wednesday, November 01, 2017 10:38 AM To: Howard, Janine (DEQ)

Subject:

RE: Dominion AS&S question Hey Janine, Determining what is considered 'routine maintenance' on utility line projects has been an ongoing process for us... our definition is as follows:

7. R.c.rutfue nt~ten~cetl;l~fi~ performed tqniEt.intain th~ griginal li.n~ at1c:lgrade; hydraulic capacity,' or pfjgil,iaJ qQ]j~@qtjqi1:,<>Hh¢ pfoj~qt. The paving of an existing road with a compacted or impervious surface and reestablishment of existing associated ditches and shoulders shall be deemed routine maintenance if 1

performed in accordance with this subsection; Regardless, this exemption is only in the SWM regulations. Routine maintenance projects are not exempt from ESC requirements. Hannah From: Howard, Janine (DEQ) Sent: Wednesday, November 1, 2017 10:25 AM To: Zegler, Hannah (DEQ) <Hannah.Zegler@deq.virginia.gov>

Subject:

Dominion AS&S question Hi Hannah, I'm working on project at the Surry Nuclear Power Station and want to make sure I get the ESC language correct. Would routine maintenance, renovation or infrastructure projects requiring ground disturbance at the site be covered by Dominion's AS&S?

Thanks, Janine Janine :Howan{

Environmental Impact Review Coordinator Office of Environmental Impact Review Division of Environmental Enhancement Virginia Department of Environmental Quality 629 E. Main Street Richmond, VA 23219 t: (804) 698-4299 f: (804) 698-4032 For program updates and public notices please subscribe to the OEIR News Feed 2

Howard, Janine (DEQ) From: Sent: To: Emily A. Hein <eahein@vims.edu> Monday, September 18, 2017 4:10 PM Howard, Janine (DEQ)

Subject:

RE: NEW PROJECT NRC SURRY POWER STATION 17-121F Good afternoon, VIMS has no comment on this project, thank you for double-checking.

Best, Emily Emily Hein Assistant to the Associate Dean Office of Research & Advisory Services eahein@vims.edu, 804-684-7482 1:~:~

From: Howard, Janine (DEQ) [1] Sent: Monday, September 18, 2017 1:40 PM To: Narasimhan, Kotur (DEQ) <Kotur.Narasimhan@deg.virginia.gov>; Emily A. Hein <eahein@vims.edu>; Watkinson, Tony (MRC) <Tony.Watkinson@mrc.virginia.gov>; Ben McFarlane <bmcfarlane@hrpdcva.gov>

Subject:

RE: NEW PROJECT NRC SURRY POWER STATION 17-121F Good Afternoon, If you have comments on this project please submit them ASAP. Thank you, Janine Jfoward Environmental Impact Review Coordinator Office of Environmental Impact Review Division of Environmental Enhancement Virginia Department of Environmental Quality 629 E. Main Street Richmond, VA 23219 t: (804) 698-4299 f: (804) 698-4032 For program updates and public notices please subscribe to the OEIR News Feed I From: Fulcher, Valerie (DEQ) Sent: Wednesday, August 16, 2017 10:28 AM 1

Virginia Marine Resources Commission Permit Application 2016071 O Printed: Tuesday September 19, 2017 4:22 PM Applicant: Virginia Power and Electric Company 5000 Dominion Boulevard Glen Allen, VA23060 Application Number: 20160710 Engineer: Application Date: May 3, 2016 Locality: Permit Type: VMRC Subaqueous Waterway: Permit Status: Issued Expiration Date: Wetlands Board Action: Public Hearing Date: Mark Eversole Surry James River July 26, 2021 Project

Description:

Maintenance Dredge (Surry Power Station Intake Cha Project Dimensions: Dredging Maintenance: 150000 Cubic Yards

Virginia Marine Resources Commission Photos for Permit Application 20160710 Printed: Tuesday September 19, 2017 4:22 PM

Virginia Marine Resources Commission Photos for Permit Application 20160710 Printed: Tuesday September 19, 2017 4:22 PM

Virginia Marine Resources Commission Photos for Permit Application 20160710 Printed: Tuesday September 19, 2017 4:22 PM

VIRGINIA DEPARTMENT OF ENVIRONMENTAL Qlu\\LITY MEMORANDUM TO: Janine Howard, DEQ/EIR Environmental Program Planner FROM: Katy Dacey, Division of Land Protection & Revitalization Review Coordinator August 18, 2017 DATE: COPIES: Sanjay Thirunagari, Division of Land Protection & Revitalization Review Manager; file Environmental Impact Review: EIR. Project No 17-12IF VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal, Surry County VA

SUBJECT:

The Division of Land Protection & Revitalization (DLPR) has completed its review of the August 3, 2017 BIR for the VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal project located at 5570 Hog Island Road in Surry, Virginia 23883 Project Scope: renewal for operating licenses for Surry Power Station Unit 1 & 2 for additional 20 years Solid and hazardous waste issues were not addressed in the submittal. The submittal did not indicate that a search of Federal or State environmental databases was conducted. DLPR staff conducted a search (0.5-mile radius)* of solid and hazardous waste databases (including petroleum releases) to identify waste sites in close proximity to the project area. DLPR search did identify five sites that are the project area. Additionally, no waste sites of possible concern were located within the zip code of the project area, 23883: DLPR staff has reviewed the submittal and offers the following comments: Hazardous Waste/R.CRA Facilities - *one is the project area V AD000619501, Surry Power Station, 5570 Hog Island Rd, Surl'y, VA 23883, Small Quantity Ge11erator (SQG) CERCLA Sites -none in the same zip code of the project area The above information related to hazardous wastes, RCRA/CERCLA sites can be accessed from EPA' s websites at https://www3.epa.gov/enviro/, https://rcrainfopreprod.epa.gov/rcrainfoweb/action/main-menu/view and https://www.epa.gov/superfund Formerly Used Defense Sites (FUDS) - none in close proximity to project area Solid Waste - 11one in close proximity to project area

Virginia Remediation Program (VRP) - none i11 close proximity to project area Petroleum Releases -four are the project area PC#20104125, Gravel Neck Turbine Station, 5208 Hog Island Road, Surry, VA 23883. Release Date: 09/15/2009. Status:.Closed. PC#l9943824, Surry Power Plant, 5570 Hog Island Road, Surry, VA 23883. Release Date: 05/16/1994. Status: Closed. PC#l9931478, SurrJ' Power Plant, 5570 Hog Island Road, Surr)', VA 23883. Release Date: 02/03/1993. Status: Closed. PC#l9891209, Surry Power Plant, 5570 Hog Island Road, Surry, VA 23883. Release Date: 03/31/1989. Status: Closed. Please note that the DEQ's Pollution Complaint (PC) cases identified should be further evaluated by the project engineer or manager to establish the exact location, nature and extent of the petroleum release and the potential to impact the proposed project. Also, the project engineer or manager should contact the DEQ's Tidewater Regional Office at (757) 518-2175 (Tanks Program) for further infonnation about the PC cases. PROJECT SPECIFIC COMMENTS None

GENERAL COMMENT

S Soil, Sediment, Groundwater, and Waste Management Any soil, sediment or groundwater that is suspected of contamination or wastes that are generated must be tested and disposed of in accordance with applicable Federal, State, and local laws and regulations. Some of the applicable state laws and regulations are: Virginia Waste Management Act, Code of Virginia Section 10.1-1400 et seq.; Virginia Hazardous Waste Management Regulations (VHWMR) (9VAC 20-60); Virginia Solid Waste Management Regulations (VSWMR) (9VAC 20-81); Virginia Regulations for the Transportation of Hazardous Materials (9V AC 20-110). Some of the applicable Federal laws and regulations are: the Resource Conservation and Recovery Act (RCRA), 42 U.S.C. Section 6901 et seq., and the applicable regulations contained in Title 40 of the Code of Federal Regulations; and the U.S. Department of Transportation Rules for Transportation of Hazardous Materials, 49 CFR Part 107. Pollution Prevention - Reuse - Recycling Please note that DEQ encourages all construction projects and facilities to implement pollution prevention principles, including the reduction, reuse, and recycling of all solid wastes generated. All generation of hazardous wastes should be minimized and handled appropriately. If you have any questions or need further information, please contact Katy Dacey at (804) 698-4274.

MEMORANDUM DEPARTMENT OF ENVIRONMENTAL QUALITY Piedmont Regional Office 4949-A Cox Road Glen Allen, VA 23060 TO: Janine Howard Environmental Program Planner FROM: Kelley West Environmental Planner DATE: September 14, 2017 804/527-5020

SUBJECT:

VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal (17-121F). I have reviewed the Federal Consistency Certification for the above referenced prof ect by which Dominion Energy Virginia is applying to the NRC for the renewal of the operating licenses for the two nuclear generating units of Surry Power Station for an additional 20 years. Surry Power Station is located in Surry, Virginia. My comments are as follows: Water-Erosion and Sediment Control and Storm Water Management: During the new license term DEQ has regulatory authority for the Virginia Pollutant Discharge Elimination System (VPDES) programs related to municipal separate storm sewer systems (MS4s) and construction activities. Erosion and sediment control measures are addressed in local ordinances and State regulations. Additional information is available at htt:p://v.,ww.deq.virginia.gov/Programs/Water/StorrnwaterManagement.aspx. Non-point source pollution resulting from any projects should be minimized by using effective erosion and sediment control practices and structures. Consideration should also be given to using permeable paving for parking areas and walkways where appropriate and denuded areas should be promptly revegetated following construction work. If the total land disturbance exceeds 10,000 square feet, an erosion and sediment control plan will be required. Some localities also require an E&S plan for disturbances less than 10,000 square feet. A stormwater management plan may also be required. For any land disturbing activities equal to one acre or more, you are required to apply for coverage under the VPDES General Permit for Discharges of Storm Water from Construction Activities. The Virginia Stormwater Management Permit Authority may be DEQ or the locality. Specific questions regarding the Stormwater Management Program requirements should be directed to John McCutcheon at DEQ-PRO 804-527-5117. Currently Surry Power Station has two VPDES permits through DEQ, the permit numbers are VARI 06343(stormwater general permit) and VA0004090 (VPDES industrial individual permit). If there are any intended changes to the systems a permit modification may be required, please contact Emilee Adamson at (804) 527-5072. Water-Wetlands: During the new license term if any impacts occur to streams or wetland features a Virginia Water Protection (VWP) permit may be needed. DEQ-PRO recommends that all construction activities avoid wetlands and streams to the maximum extent possible. For any questions

or additional information concerning VWP Permit requirements, please contact Allison Dunaway at (804) 527-5086. Air: Dominion Energy has a Title V permit (PR050336) DEQ-PRO recommends all actions shall operate in a manner consistent with air pollution control practices for minimizing emissions, especially during periods of high ozone. Fugitive dust should be kept to a minimum, (9 V AC5 60). If there are any intended changes to the systems a permit modification may be required, please contact James Kyle at (804) 527-5047. Waste: The generation or recovery of any hazardous waste materials should be tested and removed in accordance with the Virginia Hazardous Waste Management Regulations (9 VAC 20-60) and/or the Virginia Solid Waste Management Regulations (9 VAC 20-81). Please understand that it is the generator" s responsibility to determine if a solid waste meets the criteria of a hazardous waste and as a result be managed as such. In addition, asbestos waste, lead waste, or contaminated residues generated must be handled and disposed of in accordance with the VSWMR or VHWMR as applicable. DEQ reconnnends that pollution prevention principles be implemented to reduce the amount of wastes at the source, such as the re-use and recycling of construction waste materials. If you have any questions concerning hazardous/solid waste management, please contact Jason Miller at (804)527-5028.

Molly Joseph Ward Secretal)' ofNatura/ Resources Clyde E. Cristman Director COMMONWEALTH of VIRGINIA DEPARTMENT OF CONSERVATION AND RECREATION MEMORANDUM DATE: TO: FROM: September 13, 2017 Janine Howard, DEQ Roberta Rhur, Environmental Impact Review Coordinator Rochelle Altholz Deputy Director q( Ad111i11istratio11 am! Fimmce David C. Dowling Dep111y Director qf Soil and Water Co11servatio11 a11d Dam Sqfety Thomas L. Smith Deputy Director q(Operatio11s

SUBJECT:

DEQ 17-121F, VEPCO Suny Power Station Units 1 & 2 Subsequent License Renewal Division of Planning and Recreation Resources The Department of Conservation and Recreation (DCR), Division of Planning and Recreation Resources (PRR), develops the Virginia Outdoors Plan and coordinates a broad range of recreational and environmental programs throughout Virginia. These include the Virginia Scenic Rivers program; Trails, Greenways, and Blueways; Virginia State Park Master Planning and State Park Design and Construction. This project is within a section of the James River that has scenic river designation. If you have any questions about this designation, please contact Lynn Crump at 804-786-5054 or Lynn.Crump(wdcr.virginia.gov. Division of Natural Heritage The Department of Conservation and Recreation's Division of Natural Heritage (DCR) has searched its Biotics Data System for occurrences of natural heritage resources from the area outlined on the submitted map. Natural heritage resources are defined as the habitat of rare, threatened, or endangered plant and animal species, unique or exemplary natural communities, and significant geologic formations. According to the information currently in our files, the Atlantic sturgeon (Acipenser oxyrinchus, G3/S2/LE/LE) has been documented adjacent to the project site in the James River. The Atlantic sturgeon is a large fish that reaches a maximum length of about 4.3 meters and may live for several decades. The adults migrate between fresh water spawning areas and salt water non-spawning areas. They feed primarily on benthic invertebrates and small fishes as available. Stocks on the Atlantic slope have been severely reduced by overfishing (mainly late 1800s and early 1900s), pollution, sedimentation, and blockage of access to spawning areas by dams (Gilbert 1989, Burkhead and Jenkins 1991, Marine and Coastal Species Information System 1996). In Chesapeake Bay and elsewhere in the range, hypoxic events have increased and may degrade nursery habitat for Atlantic sturgeon (Secor and Gunderson 1997). Habitat loss due to dam construction and water pollution are thought to be major factors impeding full recovery of populations (Smith 1985, cited by Johnson et al. 1997; Gilbert 1989). A late maturation age and use of estuaries, coastal bays, and upstream areas of rivers for 600 East Main Street. 24'" Floor j Richmond, Virginia 23219] 804-786-6124 State Parks* Soil and Water Conservation* Outdoor Recreation Plamzhig Natural 1/eritage

  • Dam Safety alld Floodplai11 Manageme11t
  • land Conservation

spawning and juvenile development make stocks vulnerable to habitat alterations in many areas (NatureServe 2012). Please note that this species is.currently classified as endangered by the National Oceanic and Atmospheric Administration National Marine Fisheries Service (NOAA Fisheries) and by the Virginia Department of Game and Inland Fisheries (VDGIF). Due to the legal status of the Atlantic sturgeon, DCR recommends coordination with NOAA Fisheries and Virginia's regulatory authority for the management and protection of this species, the VDGIF, to ensure compliance with the Virginia Endangered Species Act (VA ST§§ 29.1-563 - 570). DCR supports studies to determine modifications designed to reduce entrainment and impingement impacts (pp. 2, 13). There are no State Natural Area Preserves under DCR's jurisdiction in the project vicinity. Under a Memorandum of Agreement established between the Virginia Department of Agriculture and Consumer Services (VDACS) and the DCR, OCR represents VDACS in comments regarding potential impacts on st~te-listed threatened and endangered plant and insect species. The current activity will not affect any documented state-listed plants or insects. New and updated information is continually added to Biotics. Please re-submit project information and map for an update on this natural heritage information if the scope of the project changes and/or six months has passed before it is utilized. The VDGIF maintains a database of wildlife locations, including threatened and endangered species, trout streams, and anadromous fish waters that may contain information not documented in this letter. Their database may be accessed from http://vafwis.org/fwis/ or contact Ernie Aschenbach at 804-367-2733 or Ernie.Aschenbach@dgif.virginia.gov. This project is located within 2 miles of a documented occurrence of a state listed animal. Therefore, DCR recommends coordination with the VDGIF, Virginia's regulatory authority for the management and protection of this species to ensure compliance with the Virginia Endangered Species Act (VA ST§§ 29.1-563 - 570). The remaining DCR divisions have no comments regarding the scope of this project. Thank you for the opportunity to comment. CC: Christine Vaccaro, NOAA Fisheries-Protected Species Division Amy Ewing, VDGIF Lynn Crump, DCR

Howard, Janine (DEQ) From: Sent: To:

Subject:

Warren, Arlene (VDH) Thursday, September 14, 2017 5:07 PM Howard, Janine (DEQ) RE: NEW PROJECT NRC SURRY POWER STATION 17-121F Attachments: Shellfish Comments 17-121 F _ VEPCO _ SurryPwrStnUnits1 &2LicenseRenewal-VDH_DSS _ResponseLtr-20170912.pdf Project Name: VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal Project#: 17-121F UPC#: N/A Location: Surry County VDH - Office of Drinking Water has reviewed the above project. Below are our comments as they relate to proximity to public drinking water sources (groundwater wells, springs and surface water intakes}. Potential impacts to public water distribution systems or sanitary sewage collection systems must be verified by the local utility. The following public groundwater wells are located within a 1-mile radius of the project site (wells within a 1,000-foot radius are formatted in bold}: PWS!D I Number ; Citv/County System Name Facility Name I 3181800 I SURRY SURRY POWER STATION WELL B INSIDE GATE 3181800 SURRY SURRY POWER STATION WELLE WAREHOUSE ROAD W 3181800 SURRY SURRY POWER STATION WELL'C HIGH LEVEL R 3181802 SURRY VA POWER CONSTRUCTION SITE WELL1 The following surface water intakes are located within a 5-mile radius of the project site: PWSID I Number System Name FacHlty Name 3700500 NEWPORT NEWS, CITY OF SK!FFES CREEK I The project is not within the watershed of any public surface water intakes. Radiological Health, Mr. Steven Harrison, Director, no comments received. OEHS Onsite Sewage & Water Services, Mr. Dwayne Roadcap, no comments received. Comments from OEHS Division of Shellfish Sanitation, Mr. Eric Aschenbach are attached. Best Management Practices should be employed, including Erosion & Sedimentation Controls and Spill Prevention Controls & Countermeasures on the project site. Well(s) within a 1,000-foot radius from proje~t site should be field marked and protected from accidental damage during construction. Materials should be managed while on site and during transport to prevent impacts to nearby surface water.. Best Regards, Arlene Fields Warren GIS Program Support Technician 1

COMMONWEALTH of VIRGINIA Department of Health DIVISION OF SHELLFISH SANITATION 109 Governor Street, Room 614-B Richmond, VA 23219 MEMORANDUM DATE: TO: FROM: 9/12/2017 Janine Howard Department of Environmental Quality

8. Keith Skiles, MPH, Director Division of Shellfish Sanitation Ph: 804-864-7487 Fax: 804-864-7481

SUBJECT:

VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal City/ County: Surry Waterbody: James River Type: D VPDES o VMRC VPA f'"l VWP Application/ Permit Number: 17-121 F JPA ~ Other: Federal Consistency Certification c.*J The prc;>ject will not affect shellfish growing waters. ~ The project is located in or adjacent to approved shellfish growing waters, however, the activity as described will not require a change in classification. C The project is located in or adjacent to condemned shellfish growing waters and the activity, as described, will not cause an increase in the size or type of the existing closure. The project will affect condemned shellfish waters and will not cause an increase in the size of the total condemnation. However, a prohibited area (an area from which shellfish relay to approved waters for self-purification is not allowed) will be required within a portion of the currently condemned area. See comments. i----*1 A buffer zone (including a prohibited area) has been previously established in the vicinity of this discharge,

            • however, the closure will have to be revised. Map attached.

This project will affect approved shellfish waters. If this discharge is approved, a buffer zone (including a prohibited area) will be established in the vicinity of the discharge. Map attached. CJ Other. ADDITIONAL COMMENTS: Area#:* 60 eta 11.'DH""'""'" mNrMl'Sl (ti H1MtH l's,*1,,h,ql*l(!ll,,,q.J)(.,i,rtn,~-*,*r111 'lr'i~" t*~~h ~ir~::,1<=$'*~*:!!-'xilti~h

Howard, Janine (DEQ) From: Kirchen, Roger (DHR) Sent: To: Wednesday, August 16, 201711:07 AM Howard, Janine (DEQ)

Subject:

RE: NEW PROJECT NRC SURRY POWER STATION 17-121F DHR,has been in consultation with the NRC regarding this project. We request that the NRC continue to consult directly with DHR, as necessary, pursuant to Section 106 of the National Historic Preservation Act (as amended) and its implementing regulations codified at 36 CFR Part 800 which require Federal agencies to consider the effects of their undertakings on historic properties. Roger Roger W. Kirchen, Director Review and Compliance Division Department of Historic Resources 2801 Kensington Avenue Richmond, VA 23221 phone: 804-482-6091 fax: 804-367-2391 roqer.kirchen@dhr. virqinia.qov ~~' *,--.~......,....,..,.,... :..... "........... :... ' from: Fulcher, Valerie (DEQ) Sent: Wednesday, August 16, 2017 10:28 AM To: dgif-ESS Projects (DGIF); Rhur, Robbie (DCR); odwreview (VDH); Dacey, Katy (DEQ); Narasimhan, Kotur (DEQ); Gavan, Larry (DEQ); Moore, Daniel (DEQ); Sepety, Holly (DEQ); West, Kelley (DEQ); Kirchen, Roger (DHR); Emily A. Hein; Watkinson, Tony (MRC); dmorris@craterpdc.org; Ben Mcfarlane Cc:: Howard, Janine (DEQ)

Subject:

NEW PROJECT NRC SURRY POWER STATION 17-121F Good morning - this is a new OEIR review request/project: Document Type: Federal Consistency Certification Project Sponsor: U.S. Nuclear Regulatory C~mmission Project

Title:

VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal Location: Surry County Project Number: DEQ #17-121F The document is available at www.deq.virginia.gov/fileshare/oeir in the NRC folder. A hard copy has been mailed to Surry County. The due date for comments is SEPTEMBE,!< 14, 2017. You can send your comments either directly to JANINE HOWARD by email (Janine.Howard@deg.virginia.gov), or you can send your comments by regular interagency/U.S. mail to the Department of Environmental Quality, Office of Environmental Impact Review, 629 E. Main St., 6th Floor, Richmond, VA 23219. 1

Howard, Janine (DEQ) From: Sent: To: Cc:

Subject:

Mark Bittner <mbittner@craterpdc.org> Thursday, August 31, 2017 1 O: 13 AM Howard, Janine (DEQ) 'Dennis Morris' FW: NEW PROJECT NRC SURRY POWER STATION 17-121F

Dear Ms. Howard:

Thank you for submitting the SURRY POWER STATION 17-121F permit for review. Based upon the Crater Commission's staff review, we find the proposal to be in full accord with the Crater Planning District Commission's environmental policy directives. Please contact us if you have any questions. Sincerely, Mark Bittner .... '""' *.;*............................. "....,.*7*..* *,................ l . Mark Sittner Crater Planning District Commission ~i:£~11.W~T,,:tmlcgr {804) 861-1666 x.237 mbittner@craterpdc.org 1964 Wakefield Street Monument Profes!llonal Building Pe~rsbutg, VA 23805 http:l{www.craterpdc.org From: Fulcher, Valerie (DEQ) [2] Sent: Wednesday, August 16, 2017 10:28 AM To: dgif-ESS Projects (DGIF); Rhur, Robbie (DCR); odwreview (VDH); Dacey, Katy (DEQ); Narasimhan, Kotur (DEQ); Gavan, Larry (DEQ); Moore, Daniel (DEQ); Sepety, Holly (DEQ); West, Kelley (DEQ); Kirchen, Roger (DHR); Emily A. Hein; Watkinson, Tony (MRC); dmorris@craterpdc.org; Ben Mcfarlane Cc: Howard, Janine {DEQ)

Subject:

NEW PROJECT NRC SURRY POWER STATION 17-121F Good morning - this is a new OEIR review request/project: Document Type: Federal Consistency Certification Project Sponsor: U.S. Nuclear Regulatory Commission Project

Title:

VEPCO Surry Power Station Units 1 & 2 Subsequent License Renewal Location: Surry County Project Number: DEQ #17-121F The document is available at www.deg.virginia.gov/fileshare/oeir in the NRC folder. A hard copy has been mailed to Surry County.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket No.: 50-280/281 Page 1 of 6 REACTOR VESSEL SUPPORT STEEL AGING EVALUATION Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Serial No.: 18-448 Docket No.: 50-280/281 Page 2 of 6 Irradiation of the reactor vessel support steel assembly has been further evaluated. Section 3.5.2.2.2.6, Reduction of Strength and Mechanical Properties of Concrete Due to Irradiation, pages 3-746 through 3-748, has been supplemented as shown in this enclosure (new text underlined and deleted text shown in strikethrough) to summarize the results of the further evaluation.

Serial No.: 18-448 Docket No.: 50-280/281 Page 3 of 6 3.5.2.2.2.6 Reduction of Strength and Mechanical Properties of Concrete Due to Irradiation Reduction of strength, loss of mechanical properties, and cracking due to irradiation could occur in PWR and BWR Group 4 concrete structures that are exposed to high levels of neutron and gamma radiation. These structures include the reactor (primary/biological) shield wall, the sacrificial shield wall, and the reactor vessel support/pedestal structure. Data related to the effects and significance of neutron and gamma radiation on concrete mechanical and physical properties is limited, especially for conditions (dose, temperature, etc.) representative of light water reactor (LWR) plants. However, based on literature review of existing research, radiation fluence limits of 1 x 1019 neutrons/cm2 neutron radiation and 1 x 108 Gy (1 x 1010 rad) gamma dose are considered conservative radiation exposure levels beyond which concrete material properties may begin to degrade markedly (Ref. 17, 18, 19). Further evaluation is recommended of a plant-specific program to manage aging effects of irradiation if the estimated (calculated) f/uence levels or irradiation dose received by any portion of the concrete from neutron (f/uence cutoff energy E > 0. 1 Me V) or gamma radiation exceeds the respective threshold level during the subsequent period of extended operation or if plant specific OE of concrete irradiation degradation exists that may impact intended functions. Higher f/uence or dose levels may be allowed in the concrete if tests and/or calculations are provided to evaluate the reduction in strength and/or Joss of mechanical properties of concrete from those f/uence levels, at or above the operating temperature experienced by the concrete, and the effects are applied to the design calculations. Supporting calculations/analyses, test data, and other technical basis are provided to estimate and evaluate f/uence levels and the plant-specific program. The acceptance criteria are described in BTP RLSB-1 (Appendix A.1 of this SRP SLR). [3.5.1-097] - Surry Power Station is a three-loop pressurized water reactor plant in which the reactor pressure vessel (RPV) is surrounded by a water-filled neutron shield tank. The RPV is supported at each of the six nozzles by a support assembly. The . bottom of each support assembly is supported by the top of the shield tank. The reactor vessel support steel assembly. utilizes a neutron shield tank that supports sliding feet that support the hot leg and cold leg nozzles on the neutron shield tank (NST) top to allow the reactor vessel nozzles to move axially as the reactor vessel heats up and cools down during plant operations. The neutron shield tank is constructed of two 1-1/2 inch thick steel shells separated by 34 inches of water. The

Serial No.: 18-448 Docket No.: 50-280/281 Page 4 of 6 weight of the RPV is carried by the neutron shield tank, and no vertical loads are transferred to the concrete biological shield (CBS) wall. The inner shell of the neutron shield tank extends continuously past the bottom of the reactor vessel to the basemat, where the vertical loads are transferred directly. Overturning moments and horizontal forces are resisted by the CBS wall through a layer of grout, which fills the 2 inch gap between the neutron shield tank and the CBS wall. The maximum temperature on both the inside and outside surfaces of the CBS wall is 125°F. The maximum water temperature of the neutron shield tank is 125°F. The maximum fluence at the ID of the RPV is 7.71 x 1019 n/cm2 (E > 1.0 MeV), determined by extrapolating surveillance program calculations to 80 years (72 EFPY). The actual EFPY value for SPS Units 1 and 2 is 68 however 72 EFPY was used in the EPRI study discussed below. Irradiation Damage of the Concrete Biological Shield EPRI Report 3002013051, "Irradiation Damage of the Concrete Biological Shield that Utilizes a Neutron Shield Tank: Basis for Concrete Biological Shield Wall for Aging Management," addresses the effects of irradiation exposure and environmental temperature on the structural capability of the CBS wall at nuclear power plants with a neutron shield tank between the RPV and CBS wall. The specific example plant utilized for development of this report was SPS, with the modeling parameters such as neutron shield tank design configuration, operating temperatures, and RPV fluence levels described above. Therefore, the plant-specific values determined and conclusions reached for the example plant in the report are directly applicable to SPS. Using an evaluation period of 72 EFPY (80 years of operation), those values and conclusions are: The maximum neutron fluence at the CBS wall surface of 1.18 x 1013 n/cm2 (E > 1.0 MeV). This is substantially below the threshold value of 1.0 x 1019 n/cm2 for E > 0.1 MeV. The estimated gamma surface dose at the CBS wall of 2.75 x 108 Rad is below the acceptability threshold of 1.0 x 1010 Rad. The maximum concrete temperature due to gamma heating is 125.1 °F, which is approximately the same as the maximum ambient temperature of 125°F at the surface of the concrete and is below the acceptable long-term local temperature limit of 200°Ffor local areas. In addition to the above conclusions, no plant-specific OE of concrete irradiation degradation has been identified. Therefore, no additional thermal and structural

Serial No.: 18-448 Docket No.: 50-280/281 Page 5 of 6 analyses are required to establish the structural capability of the CBS wall, and no plant-specific aging management program to manage the effects of irradiation is required. Irradiation of the Reactor Vessel Support Steel Assembly In 1986. DOE, EPRI. WOG. and Virginia Power contracted Stone and Webster to develop Project Topical Report (PTR): "Reactor Vessel Support for Unit No 1 Surry Power Station, Life Extension Evaluation of the Reactor Vessel Support, including Appendix 3, Resistance to Brittle Fracture of the Neutron Shield Tank Materials," to address the concern of irradiated reactor vessel (RV) supports. The PTR specifically addressed the resistance to brittle fracture of the Surry Unit 1 RV support steel materials in the NST as a result of loss of fracture toughness due to neutron irradiation embrittlement in support of plants considering initial license renewal. The applied stresses for the area of the NST subject to high neutron fluence were developed in a separate calculation and compared to critical stresses derived from the fracture toughness evaluation to determine structural integrity of the Surry Unit 1 NST for 100 years of operation. A comparison of input parameters in the PTR including configuration. toughness, fluence, and EFPY was completed for SLR. The comparison and associated evaluation determined the following values and conclusions: The fluence to the NST shell at the RV sliding foot assembly is bounded by the fluence at the NST inner shell. The PTR was conservatively estimated for 100 years of plant operation (76.8 EFPY) that yields a fast neutron fluence (E>1 Mev) of 9.5 x 1019 n/cm2 at the inside surface of the RV and a fast neutron fluence (E>1 Mev) of 5.0 x 1019 n/cm2 at the outside surface of the RV. The fast neutron f!uence (E>1 Mev) on the ID of the NST for 100 years of plant operation is based upon 90% of the fluence on the outside diameter of the RV which is 4.5 x 1018 n/cm2. The projected EFPY Value for SPS SLR is 68 EFPY which yields a fast neutron fluence (E>1 Mev) of 3.42 x 1018 n/cm2 at the inside surface of the NST. The maximum fracture toughness for 76.8 EFPY required to prevent propagation of a postulated surface flaw and postulated through wall crack was determined for the maximum design strength and design basis loading conditions. The peak stress values for the loads associated with the Surry Unit 1 NST were demonstrated to be below the critical stress for a through wall flaw and a surface flaw, thereby requiring no aging management. An update was performed in support of subsequent license renewal using the PTR methodology. The updated evaluation validated the that Surry Unit 2 NST is similar

Serial No.: 18-448 Docket No.: 50-280/281 Page 6 of 6 and bounded in design and configuration by Surry Unit 1 NST. the applied stresses for both units are consistent and have not significantly changed since the previous evaluation and the 80 year projected fluence values at the inner surface of the NSTs also remain bounded by the values in the original PTR. The subsequent license renewal evaluation concluded that brittle fracture will not occur based upon the fracture mechanics performed. which remains consistent with the previous conclusion documented in the PTR. Thus, aging due to loss of fracture toughness due to neutron irradiation embrittlement of the RV steel support assembly does not require aging management in the subsequent period of operation. In addition to the above conclusions. there is no plant-specific or industry operating experience of reactor vessel steel support assembly irradiation degradation that would impact a license renewal intended function. Generic Safety Issue 15 (GSl-15) Considerations in NUREG-0933 The PTR fracture mechanics evaluation on the reactor vessel support steel assembly predated resolution of Generic Safety Issue 15 (GSl-15), "Radiation Effects on Reactor Pressure Vessel Supports," in 1996, as reported in NUREG-0933 which states in part: The preliminary conclusion indicated that the potential problem did not pose an immediate threat to public safety. The tentative results indicated that plant safety could be maintained despite reactor vessel support structures (RVSS) radiation damage. In order to encompass the uncertainties in the various analyses and provide an overall conservative assessment, several structural analyses conducted demonstrated the following: (1) Postulating that one of the four RPV supports was broken in a typical PWR. the remaining supports would carry the reactor vessel and the load even under safe-shutdown earthquake (SSE) seismic loads; (2) If all supports were assumed to be totally removed (i.e., broken). the short span of piping between the vessel and the shield wall would support the load of the vessel. In summary, there is reasonable assurance that the Surry Units 1 and 2 reactor vessel support steel will perform the license renewal intended function during the subsequent period of operation.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 1 of 7 OTHER TOPICS THAT REQUIRE A SLRA SUPPLEMENT Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 2 of 7 The following seven topics require the SLRA to be supplemented:

1. Hot Piping Containment Penetration Thermal Insulation
2. Cracking in Copper Alloy (>15% Zn)
3. Revision 2 of PWROG-17011-NP, "Update for Subsequent License Renewal:

WCAP-14535-A, Topical Report on Reactor Coolant Pump Flywheel Inspection Elimination and WCAP-15666-A, Extension of Reactor Coolant Pump Motor - Flywheel Examination" - Issued

4. Open Cycle Cooling Water System program Enhancement 4 - Completed
5. Fire Water System program Enhancements: 1, 5 & 7 - Completed, 9 - Revised
6. Reactor Vessel Material Surveillance Program - USN RC Safety Evaluation Report Issued for Reactor Vessel Materials Surveillance Capsule Withdraw Schedules Change Request
7. Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements - Operating Experience Example 3 Updated This enclosure includes a description of each of the above topics and identifies the associated SLRA section(s) supplemented.

Change Notice 1 SPS SLRA

1. Hot Piping Containment Penetration Thermal Insulation Serial No.: rB-448 Docket Nos.: 50-280/281 Page 3 of 7 The Surry Power Station (SPS) Subsequent License Renewal Application (SLRA) inadvertently omitted the insulation within hot piping containment penetrations that have normal operating temperatures greater than 150 °F. Dominion Energy has determined that this insulation is within the scope of license renewal with an intended function of thermal insulation for limiting heat transfer to the containment concrete at the hot piping containment penetrations. The following systems have thermally insulated hot piping containment penetrations whose temperature is normally greater than 150 °F:

main steam feedwater blowdown chemical and volume control (reactor coolant letdown) Based on the above, the following SLRA Sections/ Tables have been supplemented, as shown in Enclosure 4, to address insulation within hot piping containment penetrations: SLRA Section SLRA Table 2.1.4.2 2.3.3-15 2.3.3.15 2.3.4-4 2.3.4.4 2.3.4-8 2.3.4.8 2.3.4-12 2.3.4.12 3.3.1 3.3.2.1.15 3.3.2-15 3.4.2.1.4 3.4.1 3.4.2.1.8 3.4.2-4 3.4.2.1.12 3.4.2-8 3.5.2.2.1.2 3.4.2-12

Change Notice 1 SPS SLRA

2. Cracking in Copper Alloy (>15% Zn)

Serial No.: 18-448 Docket Nos.: 50-280/281 Page 4 of 7 Copper alloy (>15% Zn) components do not require aging management of cracking in an air-indoor uncontrolled environment. NUREG-2191, "Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report," incorporated and expanded upon the guidance provided in LR-ISG-2012-02, "Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation," which identified the potential for corrosion (and cracking) under insulation and specifically addressed the condensation environment and air-outdoor environment. NURE_G-2221, "Technical Bases for Changes in the Subsequent License Renewal Guidance Documents NUREG-2191 and NUREG-2192," provides the basis for the potential for cracking of copper alloy (>15% Zn) components in air, and confirms that the presence of ammonia-based compounds and a wetted environment are needed to support the cracking aging effect. At Surry Power Station, copper alloy (>15% Zn) components in condensation environments (i.e., systems in which the temperature may be below ambient dewpoint), and in the air-outdoor environments, are identified as having the potential for cracking because the component surfaces in these environments may be wetted, and the potential for degradation of a wetted surface due to concentration of ammonia contaminants may exist. The air-indoor uncontrolled environment is assigned to components that are uninsulated, or not exposed to condensation. Since these components are not expected to be wetted through condensation or potential leakage that is retained under insulation, no concentration of low-level contaminants (ammonia or ammonia compounds) is expected. Therefore, copper alloy (>15% Zn) components exposed to air-indoor uncontrolled environment are not wetted or exposed to ammonia contaminants and are not susceptible to cracking. The internal surfaces of the service air system and instrument air system downstream of the air dryers is dry air with a dewpoint that is maintained and monitored to prevent a buildup of water in the system. Therefore, the internal surfaces of copper alloy (>15% Zn) components in the service air system and instrument air system in an air-dry environment are not susceptible to cracking. Copper alloy (>15% Zn) components in the instrument air and service air systems upstream of the air dryers with an internal condensation environment have been assigned cracking as an aging effect requiring management. Based on the above, SLRA Table 3.2.1, Table 3.3.1, Table 3.4.1, Table 3.3.2-11, and Table 3.3.2-13 have been supplemented, as shown in Enclosure 4. SLRA Section A1.23, Table A4.0-1, Item 23 and Section B2.1.23 have been supplemented, as shown in Enclosure 4, to manage cracking of copper alloy (>15% Zn) and copper alloy (>8% Al) in a condensation environment or an air-outdoor environment with the External

Change Notice 1 Serial No.: 18-448 SPS SLRA Docket Nos.: 50-280/281 Page 5 of 7 Surfaces Monitoring of Mechanical Components program. SLRA Section A 1.25, and Section B2.1.25 have been supplemented, as shown in Enclosure 4, to manage cracking of copper alloy (>15% Zn) in a condensation environment with the Inspection of Internal Surfaces of Miscellaneous Piping and Ducting Components program. Additionally, Table 3.4.2-11 has been supplemented, as shown in Enclosure 4, to reflect a change to the environment of the single valve body made of copper alloy (>15% Zn) with a condensation environment. The environment for this component was reassigned from condensation to waste water for consistency with the surrounding components.

3. Revision 2 of PWROG-17011-NP, Update for Subsequent License Renewal:

WCAP-14535-A, "Topical Report on Reactor Coolant Pump Flywheel Inspection Elimination," and WCAP-15666-A, "Extension of Reactor Coolant Pump Motor Flywheel Examination" - Issued Revision 2 of PWROG-17011-NP, Update for Subsequent License Renewal: WCAP-14535-A, "Topical Report on Reactor Coolant Pump Flywheel Inspection Elimination," and WCAP-15666-A, "Extension of Reactor Coolant Pump Motor Flywheel Examination," has been issued in response to NRC comments. Changes incorporated in PWROG-17011-NP, Revision 2 do not change the content or disposition of the TLAA described in SLRA Section 4.7.2, Reactor Coolant Pump Flywheel Fatigue Crack Growth Analysis. SLRA Section 4.8, reference 4.8-75 has been supplemented to identify PWROG-17011-NP, Revision 2 as indicated in Enclosure 4.

4. Open-Cycle Cooling Water System program Enhancement 4 - Completed The Open Cycle Cooling Water System program (Section B2.1.11) implementing.

procedures have been revised to remove the reference to carbon steel piping that was replaced, and updated to reference the replacement piping material. As a result of the above procedure revisions, Enhancement 4 in SLRA Table A4.0-1, Item #11 (Open Cycle Cooling Water System program) and SLRA Section B2.1.11 have been completed and deleted as shown in Enclosure 4.

5. Fire Water System program Enhancements: 1, 5 & 7 - Completed, 9 - Revised The Fire Water System aging management program (XI.M27), Enhancement #9 is being revised to eliminate extraneous information. The statement, "Follow-up volumetric examinations will be performed if internal visual inspections detect age-related

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 6 of 7 degradation in excess of what would be expected accounting for design, previous inspection experience, and inspection interval," is included in the SLRA Enhancement

  1. 9. The statement is being revised to align with GALL wording. The revised statement is, "Follow-up volumetric wall thickness examinations will be performed if internal visual inspections detect an unexpected level of degradation due to corrosion and corrosion product deposition."

In addition, the following enhancements in the Fire Water System program (Section B2.1.16) have been completed: Enhancement 1 Procedure inspection guidance has been revised to be consistent with the 2011 edition of NFPA 25, Section 5.2.1.1. Sprinklers at the following locations have been added to the inspection scope: Radwaste Facility, Auxiliary Boiler, Maintenance Building, Condensate Polishing Building, Laundry Building, and Machine Shop Building. Enhancement 5 Procedure flushing guidance for hydrants has been revised to be consistent with the 2011 edition of NFPA 25, Section 7.3.2. Hydrants outside the protected area that are within the scope of subsequent license renewal have been added to the flush scope. Enhancement 7 Procedure flushing guidance for mainline strainers has been revised to be consistent with the 2011 edition of NFPA 25, Sections 10.2.'1.7 and 10.2.7. The Radwaste facility mainline strainer will be inspected every five years. Enhancement 1 is clarified to note deletion of the Maintenance Building from the enhancement implementation because the Maintenance Building is also known as the Machine Shop Building. As a result of the above procedure revisions and the Enhancement 9 clarification, Enhancements 1, 5, and 7 in SLRA Table A4.0-1, Item #16 and SLRA Section B2.1.16. have been completed and deleted, and Enhancement 9 has been revised as shown in.

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Page 7 of 7

6. Reactor Vessel Material Surveillance Program - USNRC Safety Evaluation Report Issued for Reactor Vessel Materials Surveillance Capsule Withdraw Schedules Change Request By letter dated December 10, 2018, the NRC issued Safety Evaluation, "Surry Power Station, Unit Nos. 1 and 2 - Review of Reactor Vessel Material Surveillance Capsule Withdrawal Schedules" (ADAMS Accession No. ML18318A062), for the reactor vessel material surveillance capsule withdrawal schedules change request that was submitted on July 28, 2017. The December 10, 2018 letter approved a change to the withdraw schedule for Unit 1 Capsule Z from 2025 to 2027 and the withdraw schedule for Unit 2 Capsule U from 2027 to 2032.. All other aspects of the reactor vessel material surveillance capsule withdrawal schedules change request submitted on July 28, 2017 will be reviewed during the SLRA review.

SLRA Section B2.1.19 has been revised to reflect the December 10, 2018, NRC Safety Evaluation and associated withdraw schedule change for Unit 1 Capsule Zand withdraw schedule change for Unit 2 Capsule U as shown in Enclosure 4.

7. Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements - Operating Experience Example 3 Updated During the December 2015 AMP effectiveness review it was recommended that timely corrective action be taken to seal duct bank entrances for the underground 'C' RSST cables to prevent water and silt entry into a manhole to prevent exposing cables within the scope of license renewal to significant water.

Corrective maintenance was scheduled and duct bank seals were installed to correct this condition during the 2018 Fall refueling outage. The third example in the Operating Experience Summary Section of SLRA Section B2.1.39 has been updated to reflect the installation of duct bank seals as shown in.

Change Notice 1 SPS SLRA SLRA MARK-UPS CHANGE NOTICE 1 Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2 Serial No.: 18-448 Docket Nos.: 50-280/281 Page 1 of 97

Change Notice 1 SPS SLRA Affected SLRN-Se.ction Sectiorf2; 1.4.2.

  • Sectio*n:2.3.3.15 Table-2:3.3-15 Section* 2.3A.4 * *,,
  • Section 2.3,4:8 Section*2.3.4*:12 *. *
  • Table :2.3.4-4 Table 2.3.4-8 Table :2.3.4-12 Table 3.2.1, Item 3.2.1-071 Section 3.3.2.1: 15
  • Table3,3.. 1,*ltems3.3.1-132, and 182 Table 3,3.2-11

' '. '::..-~1:";/ Table 3:3.2-13. Table:3.3.2-15 Seiction 3.4:2.1.4 **

  • Secticiri *3.4.2: 1.8 *,

S~ctiori: 3.4.2: 1*: 12-.

  • SLRA MARK-UPS Serial No.: 18-448 Docket Nos.: 50-280/281 Page 2 of 97 SLRA Page(s) 2-17 through 2-20 2-101 2-167 2-214 and 2-215 2-220 and 2-221 2-226 and 2-227 2-236 2-~41 2-~48 3-154 3-220 and 3-221 3-309 and 3-316 3-387, 3-391, and 3-392 3-396 and 3-397 3-420 3-560 and 3-561 3-566 and 3-567 3-972 and 3-573 Table,3!4..1,.lteiTis.3;.4.1-063, 064, and 106 3-600 and 3-608 Table 3:4.2-4 3-625 Table 3:4.2-8 3-947 T~ble.3.4.2-11 3-666 Table' 3:4.2-12 3-669 Sectidri,3.5.2.2:1.2 -

3-732 and 3-733 Section 4.8 4-137 Section A 1.23 A-20 Section A 1.25

  • A-21 and A-22 T~ble'A4.0-1 item 11 A-67 Table A4.0-1 item 16*:

A-71 through A-73 Table A4:0-'*1

  • item-23 *,

A-82 through A-83 S~ctionB2,.1:11 * :_ 8-80 through 8-90 Section 82J: 16, ' ( 8-108 through 8-119 Section '82'. 1 :.19 .. ~* '.', 8-137 through 8-144 Section 82: 1.23

  • 8-158 through 8-165 Section 82.1.25 8-169 through 8-177 Section. 82.1.39 8-253 through 8-259

Change Notice 1 SPS SLRA Section 2.1.4.2 Serial No.: 18-448 Docket Nos.: 50-280/281 . Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. .Section 2.1.4.2, Nonsafety-Related Affecting*safety-Related, pages 2-17 through 2-20 in the* "Functional Support for Safety-Related SSC 10 CFR 54.4(a)(1) Functions" subsection, has been supplemented as follows (new text underlined): 2.1.4,2 Nonsafety-Related Affecting Safety-Related - 10 CFR 54.4(a)(2) Functional Support for Safety-Related SSC 10 CFR 54.4(a)(1) Functions This category addresses non-safety-related. SSCs that are required to function in support of a safety-related SSC intended function. The.functional requirement distinguishes this category from the other.categories, where the nonsafety-related SSCs are required only to maintain adequate integrity to preclude structural* failure. or spatial interactions. The nonsafety-related SSCs that were included within the scope of s~bsequent license renewal to support a safety-related SSC in performing a *10 CFR 54.4(a)(1) intended function are identified on the subsequent license renewal boundary drawings in blue. The* SPS UFSAR, CLB and other

  • design **basis documents were reviewed to identify nonsafety-related systems or structures required to support satisfactory accomplishment of a safety-related function. Nonsafety-related systems or structures credited in CLB documents to support a safety-related function have been* included with the scope of subsequent license

. renewal. SPS classifies systems that* are, required to perform or support a safety-related funQtion as safety-related, with the following exceptions:

  • 1.
  • The circulating water*system main condenser inlet and outlet valves are classified as safety-related because they are required to close for a number of design basis events to

.... **ensure adequate.intake canal level: The portion of the circulating water system between the condenser inlet and outlet *valves is nonsafety-related; however, it is required to .. *,.'maintain its pressure-retaining capability during those design basis events.

2. *.
  • The turbine over-speed tripping devices,Ahe stop valves, the throttle/governor valves,
  • and the associated electro-hydraulic control system are relied on to prevent excessive turbine over-speed conditions that. could* lead to turbine rotor/disk failures, resulting in

. the generation.of turbine missiles greater than those assumed in the UFSAR evaluations. However, the affected components fail to their safe condition, and the passive pressure boundary function of the valve bodies, the associated piping, and the EHC system are not needed to prevent turbine over-speed. Additionally, the valve internals and over-speed tripping devices are specifically excluded from an aging management review as active components. Page 3 of 97

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281

3.

The condensate system emergency *condensate makeup tank, together with the feedwater booster pumps and associated flowpaths, provides a backup source of water to the suction of auxiliary feedwater pumps at either unit, so that the auxiliary feedwater pumps at either unit can supply auxiliary feedwater to both units (via a discharge cross-connect line).

  • 4.

The fuel pool* cooling system removes heat from the spent fuel pool during normal operation.

5.

. The neutron shield tank cooling.. system* provides shield tank cooling during normal operation.

6.
  • The plumbing syste!ll turbine building. sump pumps and discharge piping mitigate plant flooding.
7.

The plumbing system removes water.fr:om the containment sub-surface drains to . minimize hydrostatic pressure on the containment mat liner.

8. - The plumbing ~ystem storm drains remove water from the yard area during maximum precipitation events to mitigate flooding.
9.

T:he service water system expansion joints at the bearing cooling water heat exchangers have enclosures to mitigate the potential for flooding in the Turbine Building.

10.

The ventilation* system auxiliary building, central exhaust fans and associated ducting

  • .provide ventilation for the charging pump cubicles.
11.

Some nonsafety-related portions of sys,erns are connected to safety-related (or (a)(2) functional} systems such. that a portion of the non safety-related system must retain its pressure boundary integrity to support* the integrity of the attached system. This function applies to the following systems:

a. Steam generator blowdown
b. Component cooling
c. Condensate
d. Instrument air
e. Primary grade water
f.

Vacuum priming

g. Boron recovery
h. Reactor cavity purification
i.

Liquid waste

12.

Cooling water from the component cooling system and piping insulation in hot containment piping penetrations (in the chemical and volume control, feedwater, main steam, and blowdown systems) limit heat transfer to the containment structure concrete. Page4 of 97

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 The nonsafety-related systems, or nonsafety-related portions of safety-related systems and structures that support the above functions, were included within the scope of subsequent license renewal in accordance with 10 CFR 54.4(a)(2). A supporting system review was. performed as an additional confirmation of scoping to meet 1 O CFR 54.4(a)(2) criteria. The scoping process was performed on a system and structure basis. For systems included within. the scope of subsequent license renewal in accordance with the requirements of 10 CFR 54.4(a)(1), the scoping evaluation included the identification of any additional systems,. inc;;luding nonsafety.:.related -systems, that are required to support the safety-related system intended functions. *It was then confirmed that these identified systems were also included in scope. Except as identified above,.the SPS systems required to support 1 O CFR 54.4(a)(1) were classified safety-related,*and as.such included within the scope of subsequent license renewal in accordance with'10 CFR 54.4(a)(1). The identification of support systems was not required for structures since structural* intended functions do not rely on supporting systems. The next two 10 CFR 54.4(a)(2) scoping categories are the subject of NEI 95-10, Appendix F (as referenced in NEI 17-01). The guidance.requires that, when demonstrating failures of nonsafety-related systems would not adversely impact the,ability to maintain intended functions, a distinction must be made between. nonsafety-related systems that are directly connected to safety-related systems and those that are not directly connec.ted to safety-related systems. For a nonsafety-related piping system.that is directly connected to and provides structural support for a safety-related piping system;- the. noilsafety-related piping and supports shall be included within the

  • scope of subsequent license renewal up to (1) the.analytical boundary defined in the CLB seismic analysis for the safety-related* piping or, (2) if the* seismic boundary is not clearly defined in the

. CLB information, up to and including: the point beyond which the failure of the nonsafety-related pipirig will not render the safety-related portion of the piping system unable to perform its intended function under CLB design conditions.* The location of the point beyond which the failure of the nonsafety-related piping will not render the safety-related portion of the piping system unable to perform its intended. function

  • under CLB design conditions is identified using the guidance presented in NEI 95-10, Appendix F, Section 4 (as referenced in NEI 17-01).

Page 5 of 97

Change Notice 1 SPS SLRA Section 2.3.3.15 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring an update to the system evaluation boundary and system intended functions for the chemical and volume system. Section 2.3.3.15, Chemical and Volume*Control, page 2-101, has been supplemented as follows (new text underlined and deleted text shown in strikethrough): 2.3.3.15 Chemical and Volume Control System Evaluation Boundary The evaluation boundary for the chemical and volume control system components subject to aging management review includes the letdown flowpath from the reactor coolant system through the regenerative and nonregenerative heat exchangers and letdown demineralizers to the volume control tank, the flowpaths from the volume control tank or refueling water storage tank through the charging pumps, to the reactor coolant system, the boric acid tanks, pumps and flowpaths to the charging pump suction flowpath, the reactor coolant pump seal injection flowpath and leakoff flowpath through the seal water heat exchanger, the charging pump seal coolers and oil pumps, heat exchangers and flowpaths, and nonsafety-related components that retain*water or steam in buildings containing safety-related components. Additionally subject to aging management review are local air valves and air supply piping for select letdo,wn

  • isolation valves that are credited for post-fire operation using a portable air bottle and thermal insulation on letdown lines within containment penetrations.

System Intended Functions Portions of the chemical and volume.control system perform the following safety related functions: The system provides a pressure. boundary for the reactor coolant system, controls reactor coolant system inventory and pressure*; controls core reactivity, provides high-head safety injection flow, provides reactor coolant*. pump seal injection, provides safety-related instrumentation, and provides containment isolation. Therefore, the chemical and volume control system is within the scope of license*renewal in accordance with the criteria of 10 CFR 54.4(a)(1). Insulation on hot piping containment penetrations limits heat transfer to the containment structure, and portionsPortions of the chemical and volume control system contain nonsafety-related components whose failure could prevent satisfactory accomplishment of a safety-related function. Therefore, the chemical and volume control system is within the scope of license renewal in accordance with the criterion of 1 O CFR 54.4(a)(2) for thermal insulation, spatial interaction and structural integrity. Page 6 of 97

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Portions of the chemical and volume control system are relied upon for compliance with regulations for Fire Protection (1 O CFR 50.48), Environmental Qualification (1 O CFR 50.49), and Station Blackout (10 CFR 50.63). Therefore, the chemical and volume control system is within the scope of license renewal in accordance with the criteria of 1 O CFR 54.4(a)(3). Page 7 of 97

Change Notice 1 SPS SLRA Table 2.3.3-15 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring the addition of an "Insulation (containment penetration)" line to the table. Table 2.3.3-15, Chemical and Volume Control, page 2-167, has been supplemented as follows (new text underlined): Table 2.3.3-15 Chemical and Volume Control Component Type Intended Function(s) Insulation (containment penetration) Thermal Insulation Page 8 of 97

Change Notice 1 SPS SLRA Section 2.3.4.4 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping within containment penetrations is added to the scope of subsequent license renewal requiring an update to the system evaluation boundary and system intended functions for the main steam system. Section 2.3.4.4, Main Steam, pages 2-214 and 2-215, has been supplemented as follows (new text underlined and deleted text shown in strikethrough). 2.3.4.4 Main Steam System Evaluation Boundary The evaluation boundary for the main steam system components subject to aging management review includes the safety-related steam lines from the steam generators to the main steam isolation and non-return valves, main steam safety and pressure relief valves, and to the auxiliary feedwater pump turbine; the nonsafety-related steam lines from the non-return valves to the main turbine stop valves, condenser steam dump valves and moisture-separator reheater flow control valves (and attached piping to the first isolation valve), which are credited with providing isolation during fire and station blackout events if the main steam isolation valves fail to close; sensing lines for the turbine first stage pressure transmitters which feed the ATWS Mitigation System Actuation Circuitry; and the nonsafety-related steam dump, gland steam and associated attached piping components that provide support to directly connected safety-related components, or that retain water, steam or oil in buildings containing safety-related components. Additionally, thermal insulation on hot piping within containment penetrations is subject to aging management review. System Intended Functions Portions of the main steam system perform the following safety-related functions: The system removes heat from the reactor coolant system, provides overpressure protection for the reactor coolant and main steam systems, prevents uncontrolled blowdown of more than one steam generator, provides steam to the turbine driven auxiliary feedwater pump, provides containment isolation and provides safety-related indication. Therefore, the main steam system is with in the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(1). Insulation on hot piping within containment penetrations limits heat transfer to the containment structure, and portionsPortions of the main steam system contain nonsafety-related components whose failure could prevent satisfactory accomplishment of a safety-related function. Therefore, the main steam system is within the scope of license renewal in accordance with the criterion of 10 CFR 54.4(a)(2) for thermal insulation, spatial interaction and structural integrity. Page 9 of 97

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 Portions of the main steam system are relied upon for compliance with regulations for Fire Protection (1 O CFR 50.48), Environmental Qualification (10 CFR 50.49), Anticipated Transients Without Scram (1 O CFR 50.62), and Station Blackout (1 O CFR 50.63). Therefore, the main steam system is within the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(3). Page 10 of 97

Change Notice 1 SPS SLRA Section 2.3.4.8 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring an update to the system evaluation boundary and system intended functions for the feedwater system. Section 2.3.4.8, Feedwater, pages 2-220 and 2-221, has been supplemented as follows (new text underlined and deleted text shown in strikethrough): 2.3.4.8 Feedwater System Evaluation Boundary The evaluation boundary for the feedwater system components subject to aging management review includes the safety-related feedwater piping from outside Containment through the containment penetrations to the steam generators, the safety-related auxiliary feedwater pumps and associated suction and discharge piping components, and the nonsafety-related feedwater booster pumps and associated piping components from the emergency condensate makeup tanks (which are in the condensate system) to the auxiliary feedwater pump suctions, and the nonsafety-related main feedwater pumps, first-point feedwater heaters and piping components in buildings containing safety-related components. Thermal insulation on hot piping within containment penetrations is also subject to aging management review. Additionally, nonsafety-related instrument air piping and valves provide structural support for the safety-related air accumulators and associated air supply piping components that provide closing air for the bypass feedwater regulating valves and are subject to aging management review. The main feedwater regulating valves have a similar safety-related air-to-close configuration, but the components that support that function have instrument air mark numbers and are evaluated within the instrument air system. System Intended Functions Portions of the feedwater system perform the following safety-related functions: The system provides water to the steam generators during and following design basis events, provides containment isolation, provides safety-related indication, and limits feedwater flow to a faulted steam generator. Therefore, the feedwater system is within the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(1). Insulation on hot piping within containment penetrations limits heat transfer to the containment structure, and portions of the feedwater system contain nonsafety-related components that provide a backup source of water to the suction of the auxiliary feedwater pumps, and portions contain nonsafety-related components whose failure could prevent satisfactory accomplishment of a safety-related function. Therefore, the feedwater system is within the scope of license renewal in accordance with the criterion of 1 O CFR 54.4(a)(2) Page 11 of 97

Change Notice 1 SPS SLRA Serial No.: 18-448 Docket Nos.: 50-280/281 for thermal insulation, auxiliary feedwater delivery and for spatial interaction and structural integrity. Portions of the feedwater system are relied upon for compliance with regulations for Fire Protection (1 O CFR 50.48), Environmental Qualification (1 O CFR 50.49), Anticipated Transients Without Scram (10 CFR 50.62), and Station Blackout (10 CFR 50.63). Therefore, the feedwater system is within the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(3). Page 12 of 97

Change Notice 1 SPS SLRA Section 2.3.4.12 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring an update to the system evaluation boundary and system intended functions for the blowdown system. Section 2.3.4.12, Slowdown, page 2-227, has been supplemented as follows (new text underlined and deleted text shown in strikethrough): 2.3.4.12 Slowdown System Evaluation Boundary The evaluation boundary for the blowdown system components subject to aging management review includes the safety-related steam generator blowdown piping beginning within the steam generators, connecting to piping components in Containment, through containment penetrations to the outside containment isolation valves in the Auxiliary Building, as well as downstream nonsafety-related piping components that provide piping integrity for the circulating water system, or that provide support to directly connected safety-related components, or that retain water, including the blowdown heat exchangers and associated piping components in the Auxiliary Building and Turbine Building. Additionally, thermal insulation on hot piping within containment penetrations is subject to aging management review. System Intended Functio.ns Portions of the blowdown system perform the following safety-related functions: The system isolates blowdown flow to mitigate design basis events, provides containment isolation, and provides safety-related instrumentation. Therefore, the blowdown system is within the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(1 ). Insulation on hot piping within containment penetrations limits heat transfer to the containment structure, and portionsPortions of the blowdown system contain nonsafety-related components that provide circulating water system integrity, and contain nonsafety-related components whose failure could prevent satisfactory accomplishment of a safety-related function. Therefore, the blowdown system is within the scope of license renewal in accordance with the criterion of 1 O CFR 54.4(a)(2) for thermal insulation, pressure boundary integrity, and for spatial interaction and structural integrity. Portions of the blowdown system are relied upon for compliance with regulations for Fire Protection (10 CFR 50.48), Environmental Qualification (1 O CFR 50.49), Anticipated Transients Without Scram (10 CFR 50.62), and Station Blackout (10 CFR 50.63). Therefore, the blowdown system is within the scope of license renewal in accordance with the criteria of 10 CFR 54.4(a)(3). Page 13 of 97

Change Notice 1 SPS SLRA Table 2.3.4-4 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring the addition of an "Insulation (containment penetration)" line to the table. Table 2.3.4-4, Main Steam, page 2-236, has been supplemented as follows (new text underlined): Table 2.3.4-4 Chemical and Volume Control Component Type Intended Function{s) Insulation (containment penetration) Thermal Insulation Page 14 of 97

Change Notice 1 SPS SLRA Table 2.3.4-8 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring the addition of an "Insulation (containment penetration)" line to the table. Table 2.3.4-8, Feedwater, page 2-241, has been supplemented as follows (new text underlined): Table 2.3.4-8 Feedwater Component Type Insulation (containment penetration) Intended Function(s) Thermal Insulation Page 15 of 97

Change Notice 1 SPS SLRA Table 2.3.4-12 Serial No.: 18-448 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal requiring the addition of an "Insulation (containment penetration)" line to the table. Table 2.3.4-12, Slowdown, page 2-248, has been supplemented as follows (new text underlined): Table 2.3.4-12 Slowdown Component Type Insulation (containment penetration) Intended Function(s) Thermal Insulation Page 16 of 97

Change Notice 1 SPS SLRA Table 3.2.1 Cracking of cdpper alloy >15% Zn in air clarification. Serial No.: 18-340 Docket Nos.: 50-280/281 Table 3.2.1, Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the GALL-SLR Report, Item 3.2.1-071 on page 3-154, has been supplemented as follows (new text underlined): Table 3.2.1 Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the GALL-SLR Report Item Component Aging Aging Management Number Effect/Mechanism Program 3.2.1-071 Insulated copper alloy Cracking due to sec AMP XI.M36, External (>15% Zn or>8% Al) piping, Surfaces Monitoring of piping components, tanks Mechanical Components exposed to air, condensation Further Evaluation Recommended No Discussion Not applicable. SPS has no in-scope insulated copper alloy (>15% Zn or >8% Al) piping, piping components or tanks exposed to air or condensation in the Engineered Safety Features systems. Aging of uninsulated copper allol£ (>15% Zn) components eimosed to air-indoor uncontrolled in the Engineered Safe!l£ Features is aligned to item 3.2.1-057. Cracking of copper allol£ >15% Zn in air is not expected in the absence of wetting and ammonia contaminants, which are not present in the air-indoor uncontrolled environment. The associated NUREG-2191 aging items are not used. Page 17 of 97

Change Notice 1 SPS SLRA Section 3.3.2.1.15 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Section 3.3.2.1.15, Chemical and Volume Control, pages 3-220 and 3-221 in the "Materials List" and "Aging Effects Require Management" sub-sections, have been supplemented as follows (new text underlined): 3.3.2.1.15 Chemical and Volume Control Materials The materials of construction for the chemical and volume control system component types are:

  • Calcium silicate
  • Copper Alloy
  • Copper Alloy with internal coating
  • Glass
  • Gray cast iron
  • Stainless steel
  • Steel Aging Effects Requiring Management The following aging effects, associated with the chemical and volume control system, require management:
  • Cracking
  • Cumulative fatigue damage
  • Loss of coating or lining integrity
  • Loss of material
  • Loss of preload
  • Reduction of heat transfer
  • Reduction of thermal insulation resistance Page 18 of 97

Change Notice 1 SPS SLRA Table 3.3.1 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations have been added to the scope of subsequent license renewal and cracking of copper alloy >15% Zn in air clarification. Table 3.3.1, Summary of Aging Management Programs for Auxiliary Systems Evaluated in Chapter VII of the GALL-SLR Report, Items 3.3.1-132 and 3.3.1-182 on pages 3-309 and 3-316, respectively, have been supplemented as follows (new text underlined and deleted text shown in strikethrough): Table 3.3.1 Summary of Aging Management Programs for Auxiliary Systems Evaluated in Chapter VII of the GALL-SLR Report Item Component Aging Number Effect/Mechanism 3.3.1-132 Insulated steel, copper alloy Loss of material due (>15% Zn or >8% Al), to general, pitting, piping, piping components, crevice corrosion tanks, tanks (within the (steel only); cracking scope of AMP XI.M29, due to sec (copper Outdoor and Large alloy (>15% Zn or Atmospheric Metallic >8% Al) only) storage Tanks) exposed to air, condensation 3.3.1-182 Non-metallic thermal Reduced thermal insulation exposed to air, insulation resistance condensation due to moisture intrusion Aging Management Further Evaluation Program Recommended AMP XI.M36, External No Surfaces Monitoring of Mechanical Components or AMP XI.M29, Outdoor and Large Atmospheric Metallic storage Tanks AMP XI.M36, External No Surfaces Monitoring of Mechanical Components Discussion Consistent with NUREG-2191 with a different program assigned for some components. Loss of material of ins1cJlateEl steel and copper alloy (>15% Zn or >8% Al) components and cracking of iRslllatee copper alloy (>15% Zn or >8% Al) components exposed to air-outdoor or external condensation is managed by the External Surfaces Monitoring of Mechanical Components (82.1.23) program. Cracking of copD§r allol£ (>15% Zn) eimosed to an internal condensation environment is managed bl£the lnsp§£!ion of Internal Surfaces in Miscellaneous Piping and Ducting Components (§2.1.25) program. The temperatures of components with an air-indoor uncontrolled environment are above the ambient dewpoint; therefore, a condensation environment is not applicable. Aging of uninsulated copper allol£ (>15% Zn) comgonents exgosed to air-indoor uncontrolled in the Auxilia!)l Sl£stems is aligned to items 3.3.1-114, 3.3.1-130 and 3.3.1-131. Cracking of cogger allol£ (>15% Zn) in air is not exgected in the absence of wetting and ammonia contaminants, which are not gresent in the air-indoor uncontrolled environment. Net a13131isaele. SPS llas ne in ssepe nen metallis tllei:mal ins1cJlatien e*13eseEl te aiF 9F senElensatien in tile Alcl*iliar:y Systems. Tile assesiateEl ~IUReG 2191 aging items aFe net 1cJSeEl. Consistent with NUREG-2191 Page 19 of 97

Change Notice 1 SPS SLRA Table 3.3.2-11 Cracking of copper alloy >15% Zn in air clarification. Serial No.: 18-340 Docket Nos.: 50-280/281 Table 3.3.2-11, Auxiliary Syst~ms - Instrument Air - Aging Management Evaluation, pages 3-387, 3-391, and 3-392, have been supplemented as follows (new text underlined and deleted text shown in strikethrough): Table 3.3.2-11 Auxiliary Systems - Instrument Air - Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs NUREG-2191 Table 1 Notes Type Function(s) Management Item Item Heat exchanger Copper alloy ~ ~ (air compressor DB I) Condensation lnsoection of Internal Surfaces in UI I I\\M.. '"'" I<> <> * **A G (>15% Zn) Crackinn I""'"" seal water shell) Miscellaneous Pioinn and Ductinn VII.I.A-405a 3.3.1-132 u Comoonents Heat exchanger ~ (air compressor PB Copper alloy KE) Condensation ~ Inspection of Internal Surfaces in 1.... 0 An

  • A A I....., *** A G

(>15% Zn) Crackina seal water Miscellaneous Piping and Ducting VII.I.A-405a 3.3.1-132 u ubesheet) Comoonents Copper alloy ~ ~ !valve body LB;PB;SI I) Condensation lnsoection of Internal Surfaces in m O An

  • A A I" " * **A G

(>15% Zn) Crackina Miscellaneous Pioina and Ductinn Vll.1.A-405a 3.3.1-132 u Comoonents Table 3.3.2-13 Plant-Specific Notes:

3.

The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.25l program will manage cracking of internal surfaces copper alloy (>15% Znl components in a condensation environment. Page 20 of 97

Change Notice 1 SPS SLRA Table 3.3.2-13 Cracking of copper alloy >15% Zn in air clarification. Serial No.: 18-340 Docket Nos.: 50-280/281 Table 3.3.2-13, Auxiliary Systems - Service Air -Aging Management Evaluation, pages 3-396 and 3-397, have been supplemented as follows (new text underlined and deleted text shown in strikethrough): Table 3.3.2-13 Auxiliary Systems - Service Air -Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs NUREG-2191 Table 1 Notes Type Function(s) Management Item Item Copper alloy NeR8 NeR8 Trap body LB I) Condensation lnsoection of Internal Surfaces in /11 IJ\\[').AA 1,:, '> < <<A A (>15% Zn) Crackina Miscellaneous Pioina and Ductina VI I. I.A-405a 3.3.1-132 f;1 Comoonents Table 3.3.2-13 Plant-Specific Notes:

1.

The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.25) program will manage cracking of internal surfaces copper alloy (>15% Zn) components in a condensation environment. Page 21 of 97

Change Notice 1 SPS SLRA Table 3.3.2-15 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Table 3.3.2-15, Auxiliary Systems - Chemical and Volume Control - Aging Management Evaluation, page 3-420, has been supplemented as follows (new text underlined): Table 3.3.2-15 Auxiliary Systems - Chemical and Volume Control - Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs Type Function(s) Management Insulation (E) Air - indoor (containment I! Calcium Reduction of thermal External Surfaces Monitoring of Mechanical silicate uncontrolled insulation resistance Components (B2.1.23} Elenetration} NUREG-2191 Item Vll.1.A-704 Table 1 Notes Item 3.3.1-182 8 Page 22 of 97

Change Notice 1 SPS SLRA Section 3.4.2.1.4 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Section 3.4.2.1.4, Main Steam System, pages 3-560 and 3-561 in the "Materials List" and "Aging Effects Require Management" sub-sections, have been supplemented as follows (new text underlined): 3.4.2.1.4 Main Steam System Materials The materials of construction for the main steam system component types are:

  • Calcium silicate
  • Copper alloy
  • Stainless steel
  • Steel Aging Effects Requiring Management The following aging effects, associated with the main steam system, require management:
  • Cracking
  • Cumulative fatigue damage
  • Long-term loss of material
  • Loss of material
  • Loss of preload
  • Reduction of thermal insulation resistance
  • Wall thinning Page 23 of 97

Change Notice 1 SPS SLRA Section 3.4.2.1.8 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Section 3.4.2.1.8, Feedwater System, pages 3-566 and 3-567 in the "Materials List" and "Aging Effects Require Management" sub-sections, have been supplemented as follows (new text underlined): 3.4.2.1.8 Feedwater System Materials The materials of construction for the feedwater system component types are:

  • Calcium silicate
  • Copper alloy
  • Copper alloy (>15 percent Zn)
  • Ductile iron
  • Elastomer
  • Glass
  • Gray cast iron
  • Polymer
  • Stainless steel
  • Steel Aging Effects Requiring Management The following aging effects, associated with the feedwater system, require management:
  • Cracking
  • Cracking or blistering
  • Cumulative fatigue damage
  • Hardening or loss of strength
  • Long-term loss of material
  • Loss of material
  • Loss of preload
  • Reduction of thermal insulation resistance
  • Wall thinning Page 24 of 97

Change Notice 1 SPS SLRA Section 3.4.2.1.12 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Section 3.4.2.1.12, Slowdown System, pages 3-572 and 3-573 in the "Materials List" and "Aging Effects Require Management" sub-sections, have been supplemented as follows (new text underlined): 3.4.2.1.12 Slowdown System Materials The materials of construction for the blowdown system component types are:

  • Calcium silicate
  • Nickel alloy
  • stainless steel
  • steel Aging Effects Requiring Management The following aging effects, associated with the blowdown system, require management:
  • Cracking
  • Cumulative fatigue damage
  • Long-term loss of material
  • Loss of material
  • Loss of preload
  • Reduction of thermal insulation resistance
  • Wall thinning Page 25 of 97

Change Notice 1 SPS SLRA Table 3.4.1 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal and cracking of copper alloy >15% Zn in air clarification. Table 3.4.1, Summary of Aging Management Programs for Steam and Power Conversion Systems Evaluated in Chapter VIII of the GALL-SLR Report, Items 3.4.1-063, 3.4.1-064 and 3.4.1-106 on pages 3-600 and 3-608, have been supplemented as follows (new text underlined and deleted text shown in strikethrough): Table 3.4.1 Item Number 3.4.1-063 Summary of Aging Management Programs for Steam and Power Conversion Systems Evaluated in Chapter VIII of the GALL-SLR Report Component Aging Aging Management Effect/Mechanism Program Insulated steel, copper alloy Loss of material due AMP XI.M36, External (>15% Zn or >8% Al), to general, pitting, Surfaces Monitoring of piping, piping components, crevice corrosion Mechanical Components or tanks, tanks (within the (steel only); cracking AMP XI.M29, Outdoor and scope of AMP XI.M29, due to sec (copper Large Atmospheric Metallic Outdoor and Large alloy (>15% Zn or Storage Tanks Atmospheric Metallic >8% Al) only) storage Tanks) exposed to air, condensation Further Evaluation Recommended No Discussion Consistent with NUREG-2191. Loss of material of insulated steel components exposed to air-outdoor is managed by the External Surfaces Monitoring of Mechanical Components (82.1.23) program. SPS has no in-scope insulated copper alloy (>15% Zn or >8% Al), piping, piping components, or tanks exposed to air-outdoor or condensation in the Steam and Power Conversion System. The temperatures of components with an air-indoor uncontrolled environment are above the ambient dewpoint; therefore, a condensation environment is not applicable. The asseoiateel NbJReG 2191 agiR§ items are Rat !lseel. Aging of co1112er allol£ (>15% Zn} com11onents in air-indoor uncontrolled environment in the Steam and Power Conversion Sl£Stems is aligned to item 3.4.1-054. Cracking of co1111er allol£ > 15% Zn in air is not ex11ected in the absence of wetting and ammonia contaminants, which are not 11resent in an air-indoor uncontrolled environment. Page 26 of 97

Change Notice 1 SPS SLRA Item Component Number 3.4.1-064 Non-metallic thermal insulation exposed to air, condensation 3.4.1-106 Copper alloy (>15% Zn or >8% Al) piping, piping components exposed to air, condensation Aging Aging Management Effect/Mechanism Program Reduced thermal AMP XI.M36, External insulation resistance Surfaces Monitoring of due to moisture Mechanical Components intrusion Cracking due to sec AMP XI.M36, External Surfaces Monitoring of Mechanical Components Further Evaluation Recommended No No Serial No.: 18-340 Docket Nos.: 50-280/281 Discussion Net a13131isatlle. SPS Ras RS iR sse13e RSR metallis IR8Flflal iRSlallalieR 8*l38S8EI le aiF 8F S8REl8RSatieR iR !Re Steam aREI PeweF GeR*,eFSieR Systems. +Re assesiateEI ~JUReG 2191 agiR!I items aFe Rel 1a1seEI. Consistent with NUREG-2191. ~Jet a1313lisatlle. SPS Ras Re iR sse13e se1313eF alley {::.15% 6R 8F ::.8%,11,1) sem13eReRIS 8*138881 le e1a11EleeF aiF 8F e~emal seREleRsatieR iR !Re Steam aREI PeweF GeRveFSieR systems. +Re seRtamiRaRls ResessaF}' le 13rnmete SFaskiR!I ef S8l3l38F alley {::.15% 6R) sem13eReRIS aFe Rel 8*l38SleEI iR aR iREl88F aiF 8F iRleFRal 68REleRsalieR eR*JiFeRmeRI. AgiR§ ef S8l3!38F alley {::. 15% 6R) sem13eReRIS iR iREl88F aiF 8F iR!eFRal S8REl9RSalieR eR>JiFeRmeRIS iR tRe Steam aREI PeweF GeR>JeFSi8R systems aFe aligReEI te item J.4.1 Q54. +Re assesiateEI ~JUReG 21 Q1 agiR!I items aFe R8l lalS8EI. Not a1212licable. SPS has no in-sco12e co1212er alloy: (>15% Zn or >8% Al} com12onents ex12osed to outdoor air or condensation in the Steam and Power Conversion sy:stems. Aging of co1212er alloy: (>15% Zn} com12onents in an air-indoor uncontrolled environment in the Steam and Power Conversion Sy:stem is aligned to item 3.4.1-054. Cracking of co1212er allol£ >15% Zn in air is not ex12ected in the absence of wetting and ammonia contaminants, which are not 12resent in an air-indoor uncontrolled environment. The associated NUREG-2191 aging items are not used. Page 27 of 97

Change Notice 1 SPS SLRA Table 3.4.2-4 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Table 3.4.2-4, Steam and Power Conversion System - Main Steam - Aging Management Evaluation, page 3-625, has been supplemented as follows (new text underlined): Table 3.4.2-4 Steam and Power Conversion System - Main Steam - Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs NUREG-2191 Type Function(s) Management Item Insulation {E) Air - indoor (containment I! Calcium Reduction of thermal External Surfaces Monitoring of Mechanical VIII.H.S-403 silicate uncontrolled insulation resistance Components (B2.1.23) penetration) Table 1 Notes Item 3.4.1-064 8 Page 28 of 97

Change Notice 1 SPS SLRA Table 3.4.2-8 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Table 3.4.2-8, Steam and Power Conversion System - Feedwater - Aging Management Evaluation, page 3-647, has been supplemented as follows (new text underlined). Table 3.4.2-8 Steam and Power Conversion System - Feedwater - Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs Type Function(s) Management Insulation (E) Air - indoor (containment I! Calcium Reduction of thermal External Surfaces Monitoring of Mechanical silicate uncontrolled insulation resistance Components (82.1.23) penetration) NUREG-2191 Item VIII.H.S-403 Table 1 Notes Item 3.4.1-064 8 Page 29 of 97

Change Notice 1 SPS SLRA Table 3.4.2-11 Serial No.: 18-340 Docket Nos.: 50-280/281 During preparation of the cracking of copper alloy >15% Zn in air clarification, the following correction was also identified. Table 3.4.2-11, Steam and Power Conversion System - Steam Drains - Aging Management Evaluation, page 3-666, has been supplemented as follows (deleted text shown in strikethrough): Table 3.4.2-11 Steam and Power Conversion System - Steam Drains - Aging Management Evaluation Component Intended Material Environment Aging Effect Requiring Aging Management Programs NUREG-2191 Type Function(s) Management Item Valve body LB;PB Copper alloy (E) Air - indoor None None VIII.I.SP-6 uncontrolled (I) Condensation None None VIII.I.SP-6 (I) Waste water Loss of material; flow Inspection of Internal Surfaces in Miscellaneous VI I.E5.AP-272 blockage Piping and Ducting Components (B2.1.25) Copper alloy (E) Air - indoor None None VIII.I.SP-6 (>15% Zn) uncontrolled (I) GeREleRsatieR NeR8 NeR8 VIII.I.SF! 6 (I) Waste water Cracking Inspection of Internal Surfaces in Miscellaneous VI I.E5.A-473c Piping and Ducting Components (B2.1.25) Loss of material Selective Leaching (B2.1.21) VII.E5.A-547 Loss of material; flow Inspection of Internal Surfaces in Miscellaneous VII.E5.AP-272 blockage Piping and Ducting Components (B2.1.25) Table 1 Notes Item 3.4.1-054 A 3.4.1-054 A 3.3.1-095 A, 1 3.4.1-054 A 3.4A Q54 A 3.3.1-160 A 3.3.1-072 A 3.3.1-095 A, 1 Page 30 of 97

Change Notice 1 SPS SLRA Table 3.4.2-12 Serial No.: 18-340 Docket Nos.: 50-280/281 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Table 3.4.2-12, Steam and Power Conversion System - Slowdown - Aging Management Evaluation, page 3-669, has been supplemented as follows (new text underlined): Table 3.4.2-12 Steam and Power Conversion System - Slowdown - Aging Management Evaluation Component lntende~ Material Environment Aging Effect Requiring Aging Management Programs Type Function(s) Management Insulation (El Air - indoor (containment Calcium Reduction of thermal External Surfaces Monitoring of Mechanical I! silicate uncontrolled insulation resistance Components (82.1.23) penetration) NUREG-2191 Item VIII.H.S-403 Table 1 Notes Item 3.4.1-064 8 Page 31 of 97

Change Notice 1 SPS SLRA Serial No.: 18-340 Docket Nos.: 50-280/281 Section 3.5.2.2.1.2 Thermal insulation on hot piping containment penetrations is added to the scope of subsequent license renewal. Section 3.5.2.2.1.2, Reduction of Strength and Modulus Due to Elevated Temperature, pages 3-732 and 3-733, has been supplemented as follows (new text underlined and deleted text shown in strikethrough): 3.5.2.2.1.2 Reduction of Strength and Modulus Due to Elevated Temperature Reduction of strength and*modulus of concrete due to elevated temperatures could occur in PWR and BWR concrete and steel containments. The implementation of 10 CFR 50.55a and ASME Code Section XI, Subsection IWL would not be able to identify the reduction of strength and modulus of concrete due to elevated temperature. Subsection CC-3440 of ASME Code Section Ill, Division 2, specifies the concrete temperature limits for normal operation or any other long-term period. Further evaluation is recommended of a plant-specific AMP if any portion of the concrete containment components exceeds specified temperature limits [{i.e., general area temperature greater than 66°C (Celsius) [150°F (Fahrenheit)] and local area temperature greater than 93°C (200°F)}. Higher temperatures may be allowed if tests and/or calculations are provided to evaluate the reduction in strength and modulus of elasticity and these reductions are applied to the design calculations. Acceptance criteria are described in Branch Technical Position (BTP) RLSB-1 (Appendix A.1 of this SRP SLR). [3.5.1 003] UFS/\\R Sestion 15.5.1.8 dissusses high temperature pipe penetrations. Containment strusture piping penetrations for all thermally hot (over 150°F) piping systems are sleeved penetrations. The main steam and feedi.*.'ater penetrations are provided with adequate spase between the piping and the sleeve for the nesessary pipe insulation, and for a pipe soil outside the insulation through whish somponent oooling

  • .Yater is sirsulated. This sooling soil reduses the temperature of the slee*1e and prevents any exsessive heating (over 150°F) of the sonsrete in sontast with the sleeve. UFSAR Sestion 15.6.2.2.1 dissusses the reastor vessel support, whish sonsists of six sliding foot assemblies mounted on the neutron shield tank. The neutron shield tank is a double walled sylindrisal struoture that transfers the loadings to the heavy reinforoed sonsrete mat of the Containment strusture. The tank also serves to minimize gamma and neutron heating of the primary sonsrete shield. UFSAR Sestion 5.3.1.2 dissusses the design basis for the Containment ventilation systems. The ventilation systems were originally designed to limit the Containment bulk air temperature to beloi.\\' 105°F. Operating experiense has demonstrated that the heat load in Containment exseeds the original design estimates but that the ventilation systems are adequate to maintain the Containment bulk air temperatures less than Page 32 of 97

Change Notice 1 SPS SLRA Serial No.: 18-340 Docket Nos.: 50-280/281 125°F. The penetration sooling soils are managed for aging in the somponent sooling system (Sestion 2.3.3.8). The sontainment ventilation system is subjest to Teshnisal Spesifisation limitations on sontainment bulk air temperature. Therefore, the aging effests due to elevated temperatures are not applisable for SPS, and a plant spesifis aging management program is not required. [3.5.1-003] - UFSAR Section 15.5.1.8 discusses high temperature pipe penetrations. Containment structure piping penetrations for all thermally hot (over 150°F) piping systems are sleeved penetrations. The hot piping containment penetrations are provided with adequate space between the piping and the sleeve for the necessary pipe insulation, and for a pipe coil outside the insulation through which component cooling water is circulated. This cooling coil and insulation reduce the temperature of the sleeve and prevent any heating of the concrete in contact with the sleeve from exceeding the ACI Code limit of 200°F for local areas. UFSAR Section 15.6.2.2.1 discusses the reactor vessel support, which consists of six sliding foot assemblies mounted on the neutron shield tank. The neutron shield tank is a double-walled cylindrical structure that transfers the loadings to the heavy reinforced-concrete mat of the Containment structure. The tank also serves to minimize gamma and neutron heating of the primary concrete shield. UFSAR Section 5.3.1.2 discusses the design basis for the Containment ventilation systems. The ventilation systems were originally designed to limit the Containment bulk air temperature to below 105°F. Operating experience has demonstrated that the heat load in Containment exceeds the original design estimates but that the ventilation systems are adequate to maintain the Containment bulk air temperatures less than 125°F. The containment ventilation system is subject to Technical Specification limitations on containment bulk air temperature. The penetration cooling coils are managed for aging in the component cooling system (Section 2.3.3.8). The insulation for the containment penetrations is managed for aging in the main steam system (Section 2.3.4.4), the feedwater system {Section 2.3.4.8), the blowdown system {Section 2.3.4.12), and the reactor coolant system letdown, which is managed as part of the chemical and volume control system (Section 2.3.3.15). The aging effects due to elevated temperatures are not applicable for SPS, and a plant-specific aging management program is not required. Page 33 of 97

Change Notice 1 Surry Power Statton, Units 1.. and 2 AppHcation for Subsequent License Re.newal TI.me-Limited Aging *Anaiyses 4.s-eo* NUREG/CR""5704, "Effects of.LWR coolant Environ men.ts on Fatigue De$ign curv~ of Austenitic Stainless Steels,.. ' April 1999. (ML031480394) 4.8-61 WCAP-16990,-P (Proprietary},. Revision o, "Surry Units t and 2 Measurement Uncertainty Recapt1,1re Power Uprate Proje*ct EnQineer'ing Report." May 201 O. 4.8-62 Inspection and Enforcement Bulletin (IEB) 79.. 01B. "Environmental Qualification of Class 1E Equipment." (ML080310648) 4.8-63' IEEE Standard 323-1974, "IEEE Standard for-Qualifying C1a$S 1 E Equipment for Nuclear Power Generating Stations:~ (ML032200206) 4:8-64 11448-EA-62, Revision O, Add. *ooc, "Reactor Containment Liner Fatigue Evaluation for BO-Year Plant Life." 4.8-65 Crane Manufactuters Association of America $pecification 70, 1975. 4.8-96 NUREG-0612, "Controi of Heavy Loads at Nuclear power Plants, July 1980. (ML070250180) 4.8-67 ANSI Standard 830,11-1973, "Monorail Systems and Underhung Cranes." 4.8-68 ANSI Standard 830.16-197~. "Overhead Hoists." 4.8-69 ASM5Standard HST-4; uPerfortnance Standard for Overhead Electric Wire Rope Hoists." 4$-70 Electric Overhead Crane Institute (EOCI) Specification *51 for Electric-Overhead TravelinQ Cran~s. 4.8-71 NRC Generic Letter 81-07, "Control of Heavy Loads." 4.8~72 WCAP-14535A, "Topica,I Report on Reactor Coolant Pump Flywheel Inspection Elimination," November 1996. 4.8-73 NRC Letter, "Surry Power Station, Uriits 1 :and 2 - Issuance of Amendments to Extend the Inspection Interval fQr Reactqr Coolant Pump. Flywheel~ (TAC Nos'. MC4215 and MC42.16)," June 21, 2005. (ML051640591) 4.8-74, WCAP-15666-A, Revi~ion 1, "Extension of Reactor Coolant Pump Motor Flywheel Examination." October 2003. 4.8-75 PWROG-17011-NP, Revision ;t.,2, "Update for Subsequent License Renewal: WCAP:.*14535A, 'Topical Report on Reactor*Coolant Pump Flywheel Inspection Elimination' and WCAP-15666.-A, '*Extension of Reactor Coolant Pump Motor Flywheel Examination,'" May 2Q~January. _2019. Page 34 of 97

Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Change Notice 1 Appendix A - UFSAR Supplement A1.23 EXTERNAL SURFACES MONITORING OF MECHANICAL COMPONENTS The External Surfaces Monitoring of Mechanical Components program is an existing condition monitoring program that manages loss of material, cracking, and reduction of heat transfer of metallic components; hardening or loss of strength, loss of material, and cracking or blistering of polymeric components; loss of preload of HVAC closure bolting; and reduced thermal insulation resistance. Periodic visual inspections, not to exceed a refueling outage interval, of metallic, polymeric, and insulation jacketing (insulation when not jacketed) are conducted. For certain materials, such as flexible polymers, physical manipulation or pressurization to detect hardening or loss of strength is used to augment the visual inspections conducted under this program. Surface examinations or ASME Code, Section XI, visual exa_~inations (VT-1) are conducted to detect cracking of stainless steel... aluminum and copper alloy {>15% Zn or >8% Al) components. A sample of outdoor component surfaces that are insulated and a sample of indoor insulated components exposed to condensation (due to the in-scope component being operated below the dew point), are periodically inspected every ten years during the subsequent period of extended operation. Following insulation removal, surface examinations or ASME Code, Section XI, visual examinations (VT-1) are conducted to detect loss of material and cracking of the component surfaces. Non-ASME Code inspection procedures include inspection parameters such as lighting, distance, offset, and surface conditions. Acceptance criteria are such that the component will meet its intended function until the next inspection or the end of the subsequent period of extended operation. Qualitative acceptance criteria are clear enough to reasonably assure a singular decision is derived based on observed conditions. The external surfaces of components that are buried or in underground environments are inspected by the Buried And Underground Piping And Tanks program (A 1.27). The external surfaces of outdoor tanks and indoor large volume metallic storage tanks (capacity >100,000 gallons) are inspected by the Outdoor and Large Atmospheric Metallic Storage Tanks program (A 1.17). Loss of material due to boric acid corrosion is managed by the Boric Acid Corrosion program (A 1.4). PageA-20 Page 35 of 97

Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Change Notice 1 Appendix A - UFSAR Supplement A1.24 FLUX THIMBLE TUBE INSPECTION The Flux Thimble Tube Inspection program is an existing condition monitoring program that manages loss of material due to wear by inspecting for the thinning of flux thimble tube walls. Flux thimble tubes provide a path for the in-core neutron flux monitoring system detectors and forms part of the reactor coolant system pressure boundary. Flux thimble tubes are subject to loss of material at certain locations in the reactor vessel (RV) where flow-induced fretting causes wear at discontinuities in the path from the RV instrument nozzle to the fuel assembly instrument guide tube. The thimble tube design is a double-walled, asymmetrical configuration to accommodate thermocouple leads located in the annulus between the inner and outer flux thimble tubes. The outer tube is the component that is most susceptible to wear due to its contact with the discontinuities. The inner tube through which the incore detector travels is the reactor coolant system pressure boundary. The double wall design significantly reduces the potential for wear of the inner tube pressure boundary. Periodic eddy current examinations are performed to confirm the integrity of the inner flux thimble tube, and are consistent with the recommendations of NRC Bulletin 88-09, "Thimble Tube Thinning in Westinghouse Reactors." A1.25 INSPECTION OF INTERNAL SURFACES IN MISCELLANEOUS PIPING AND DUCTING COMPONENTS The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program is an existing condition monitoring program that manages loss of material, cracking, reduction of heat transfer, and flow blockage of metallic components. The program also manages hardening. or loss of strength, loss of material, cracking or blistering, and flow blockage of polymeric components. This program consists of visual inspections of all accessible internal surfaces of piping, piping components, ducting, heat exchanger components, polymeric and elastomeric components, and other components exposed to air, condensation, diesel exhaust, fuel oil, lubricating oil, and any water environment. Aging effects associated with items (except for elastomers) within the scope of the Open-Cycle Cooling Water System program (A1.11), Closed Treated Water Systems program (A 1.12), and Fire Water System program (A 1.16) are not managed by this program. For certain materials, such as flexible polymers, physical manipulation or pressurization to detect hardening or loss of strength is used to augment the visual examinations conducted under this program. Surface examinations or ASME Code, Section XI, visual examinations (VT-1) are conducted to detect cracking of stainless steel.,_ aluminum and... copper alloy (> 15% Zn) components. PageA-21 Page 36 of 97

Table A4.0-1 Subsequent Liceose Renewal Commitments "U m m cc ::, CD o (,J - ~~ 0 C: 11 Program Open-Cycle* Cooling Water program Commitment The Open-Cycle Cooling Water program is an existing preventive, mitigative, condition monitoring, and performance monitoring program ~hat will t?e enhanced as follo~s:

1. Selected fiberglass reinforced plastic (FRP> piping in the service water system will be replaced with a more degradation resistant material such as copper-nickel (Cu-Ni) prior lo entering. the subsequent period of extended operation. FRP piping associated with the Units 1 and 2 charging pump cooling water subsystems, service water rotating.strainers, and the control room chillers may tie replaced as part of a time-phased program.
2. M6difications n~essary to provide new* chemical inJection site upstream of tlie service water rota~ng strainers will be completed prior to entering the subsequent period of extended operation.
3. The internal lining of 24 inch and larger service water inlet piping with carbon fiber reinforced polymer, With the exception* of the recirculation spray heat exchanger piping downstream of the inlet motor-operated valves, will be completed prior to entering the subsequent period of extended operation.

~ PFeeeat1i:es,,..m be f8¥isea ta Femeve PefareR.se te.ti:is saA:!eA steel f,ipif:lg tl'let was ra~aseel aREi *will iRsli,iele tl:le replaeeA'leRt A'laterial.{Completed SLRA Change'Notice 1)

5. Procedures will be revised to provide additional guidance for identifying and evaluating applicable concrete aging effects such as loss of material due to delamination, exfoliation, spal!ing, popout, scaling, or cavitation; and cracking due to chemical reaction, or corrosion of reinforcement.
6. Procedures will be revised to. require personnel who perform inspections and evaluation of concrete components to be qualified consistent with \\he qualifications identified in the Structures Monitoring program (82.1.34) that are consistent with the requirements of ACI 349.3R
7. Prqcedures will be revised to require trending of charging pump lube oil cooler and emergency service water pump engine heat exchanger inspection results by Engineering.
8. Procedures will *be revised to require trending of wall thickness measurements. The frequency and number of wall thickness measurements will be based on trending results.

~- Procedures will be revis*ed to include verification that, predicted wall thicknesses at the next scheduled inspection will be greater'than the minimum wall thicknesses.

10. Procedures wili be revised to include criteria for the extent and rate*of on-going degradation that will prompt additional corrective actions.
11. Procedures wiU be revised to identify acceptance criteria for visual lnspecpon of conc:rete plpfng and components such as the absence of cracking and toss of material, provided that minor cracking and loss of material in concrete may be acceptable wh~re there is no evidence of leakage, exposed rebar or reinforcing "hoop" bands or rust staining from such reinforcing.elements.
12. Procedures will be revised to ensure that for ongoing degradation mechanisms (e.g., MIC), the frequency and extent of wall thickness inspections at susceptible locations are increased commensurate with the significance of the degradation.

al ~ ~ Surry Power station, Units 1 and 2 PageA-67 Application for Subsequent License Renewal Appen~lix A - UFSAR Supplement AMP lmplemen~tion Program enhancements for SLRWIII be implemented 82.1*.11 6 months prior to the subsequent period of extended operation.. Change Notice 1

Table A4.0-1 Subsequent License Renewal Commitments Program Commitment The Fire Water System program is an existing condition monitoring program that will be enhanced as follows: ~ f2feseE11:1res iASf!estieA 91:1ielaAee wrn lee re*~se~ ta FeEjl;li;:e r-e19laeaffleAi ef aRy s13Fir1~lef tl=fa~ si'l1:w1s aA)' ei the f;sllawi"'g: laal~a!iJe, 68FF8Si9A. ~l=lysieal elaff'!age, laaeliRg, 1a1aiA1iR9 !;!Riess ~aiAlee! by U=te S~FiAkleF FR8R!:lfa6tt:IF9F, 9F iRS8F~6t efieAta!iaR. S13FiAkleFS al tl=le fellawiRij lesa~i0as will lee aeeteel te the lest sse19e: +!:le Raelwas~e J;:asillty, A1:111iliaFIJ BeileF. MaiRteAaAse 81:1ileiAQ,~REleRsate Pelisl=tiR§ 81:1ileliR!iJ. la1:1RaPJ 81:1ileiR9* aAa-Masl=liAe Sl:te13 Q1:1ileliR§. (Completed Change-Notice 1)

2. Prior to 50 years in service, sprinkler heads will be submitted for field-service testing by a recognized testing laboratory consistent with NFPA 25, 2011 Edition, Section 5.3.1. Additional representative samples will be field-service tested every 1 o years thereafter to ensure signs of aging are detected in a timely manner. For wet pipe sprinkler systems, a one-time test of sprinklers that have been exposed to water including the sample size, sample selection criteria, and minimum time in service of tested sprinklers will be performed.
3. Procedures will be revised to specify:
a. Standpipe and system flow tests for hose stations at the hydraulically most limiting locations for each zone of the system on a five year interval to demonstrate the capability to provide the design pressure at required flow.
b. Acceptance criteria for wet pipe main drain tests. Flowing pressures from test to test will be monitored to determine if there is a 10% reduction in full flow pressure when compared to previously performed tests. The Corrective Action 16 Fire Water Program will determine the cause and necessary corrective action.

System program C. If a flow test or a main drain test does not meet acceptance criteria due to current or projected degradation additional tests are conducted. The number of increased tests is determined in accordance with the corrective action process: however, there are no fewer than two additional tests for each test that did not meet acceptance criteria. The additional inspections are completed within the interval in which the original test was conducted. If subsequent tests do not meet acceptance criteria, an extent of condition and extent of cause analysis is conducted to determine the further extent of tests. The additional tests include at least one test at the other unit with the same material, environment, and aging effect combination. d, Main drains for the standpipes associated with hose stations within the scope of subsequent license renewal will also be added to main drain testing procedures. 4, Procedures will be revised to perform system flow testing at flows representative of those expected during a fire. A flow resistance factor (C-factor) will be calculated to compare and trend the friction loss characteristics to the results from previous flow tests. .§,. PFeseel1:1res f.eF l=tye!FeA~ ft1:1sl:liR§,,,ill 9~"1iseel te RSSll:liFe fl:llly e13eRiF1§ tl:le A~e!FaRt aAel fl:llly 41a>.*,*iA§ 11:!e RYE!FaRI faF RS less tl=laA eAe miA1:1te aAel l:IR~I JeFei§R meteFial !:las eleafea. IA aEle!ilieA, 19Feeael1:1Fes will be Fe'liseel ta eesewe elFaiRiR§ et ~e l:iyEIFaRt eaFFel aREI alse FeeiuiFe !t:le leaFFel ee 191:1FF.19eel etP,* sl=te1;1le! it Ret EIFaiA witRiA 13g miR1:1tes. MyelFaAts e1:1tsiele-ll=le 19rete~eel ai:ea tRat aFe witt:liR tRe sea13e ef s1:1esaei1:1eRI lieeAse F9Re*~al will se ae!elec:it& tl'le fi1:1sl=I sse19e. {Completed Ql:!ange Notice 1) "U Ill m co ::::, CD o (,.) - OJ~ 0 C: co ~.i:,.. Surry Power Station, Units 1 and 2 PageA-71 Application for Subsequent License Renewal Appendix A - UFSAR Supplement AMP Implementation Program will be implemented and inspections or tests begin 5 years before the subsequent period of extended operation. Inspections or tests that are to be completed prior to the subsequent 82.1.16 period of extended operation are completed 6 months

  • prior to the subsequent period of extended operation or no later than the last refueling outage prior to the subsequent period of extended operation.

Change* Notice 1

iJ D) cc r - CD 0 c,.:,- (.Og 0 C 16 Subseq~ent License Renewal Commitments Program Commitment

6. The Fire Water System program will bE! relfised to penodically inspect the insulated, exterior surfaces of the fire water tanks on a 10-year frequency during the subsequent period of operation. Insulation is removed to provide a minimum inspection population of 25 one~square foot samples. The samples will be distributed in such a way that inspections occur on the tank dome, nE!ar the tank bottom, a_t points where structural supports, pipe, or instrument nozzles penetra_te the insulation and where water-could collect. In addition, inspection locations will be based on the likelihood of corrosiqn under insulation occurring.

+-,- PFeseE!1:1Fes faF ff!aiRliRe stralP.eF411:lsl'liR§,.,,,m ee reYisea te feetl!ir-e fl1:1stiiR§l llF1til sleaF wateF is eeseP.SeE! afteFEi:l~ a~Fatiefl eF Rew le!*. IA asaitie~i=mieR, iAe Reeiwaste_ Fasm~ ff!e1r11!Re stfaiReF will fE!j\\:liFe aR iRs13esijeA e,~efY fl,,<e, ;ceaFs feF e!aR'!a§eel eR!J GG1Ffeeeel !ili!IRS.,comgle!§d Chance No~~ 1 l

8. A procedure will be created to provide a Turbine,Building oil deluge systems spray nozzle air flow test to ensure that patterns are not impeded by plugged nozzles., to ensure that nozzles are correctly positioned, and to ensure that obstructions do not prevent discharge patterns from wetting surfaces to be protected.
9. Procedures will be revised to perform internal visual inspections of sprinkler and deluge system piping to identify internal corrosion, foreign material, anp obstructions to flow. Follow-up volumetric examinations will be performed if internal visual inspections detect age-related degradation in exce$S of what would be expected accounting for design, previous iospeqtion experience, and inspection interval. If organic or foreign material, or internal flow blockage that could result in failure of system function is identified, then an obstruction investigation will be performed within the Corrective Action Program ttiat Fire Water includes removal ofthe material, an extent of condition determination, review for increased inspections, extent of faltow-up*

System program examinations, and a flush in' accordance with NFPA 25, 2011 Editi9n,.Annex D.5, Flushing Procedures. The Internal visual inspectionswill consist of the following:

a. Wet pipe sprinkler systems - 50% of the wet pipe sprinkler systems in scope for subsequent license renewal wm have visual internal inspections of piping by removing a hydraulically rernote sprinkler, performed every five years, consistent with NFPA 25, 2011 Edition, Section 14.2. During, the next five-year inspection period, the alternate systems previously not inspected shall be inspected.
b. Pre-action sprinkler systems - pre-actiQn, sprinkle~ systems In scope for subsequent licens~ renewal. will have visual internal inspections of piping by removing a hydraulically remote nozzle, performed every five. ye1us; consistent with NFPA 25, 2011 Edition, Section 14.2.

C. Deluge systems - deluge systems in scope for subsequent license renewal will have visual internal Inspections,of piping by removing a hydraulically remote nozzle. performed every five years, consistent with NFPA 25, 2011 Edition, Section 14.2.

10. ProQfJdure will be revised to provide iospectitm guidance rel~te9 to lighting, distance and offset for non-ASME _Code inspections. The procedure will specify adequate lighting be verified at the inspection location ta detect degradation.

Lighting may be permanently installed, temporary, or portable (e.g., flashlight), as appropriate. For accessible surface inspections, inspecting from a distance of two to four feet (or less) will be appropriate. For distant surface inspections, viewing aids such a.s binoculars may be used. For viewing angles which may prevent adequate inspectlon, a viewing aid such as an inspection mirror or boroscope should be used.

co

....,.. ~ Surry Power Station, Units 1 and 2 Pag~A-72 Application for Subsequent Licer:ise Renewal Appendix A-UFSAR'Supplement AMP Implementation Program will be

  • implemented and_

'inspections or tests begin* 5 years

  • b~forethe subsequent period of extended operation.

Inspections ortests -that are to be completed prlor to -the subsequent B2.1:16 period of extended ,operation are completed 6 months _prior to the

subsequent period

, of extended operation orno later

  • 'than the last

-refueling outage -priorto the subsequent period of extended opefc!tton. ChanQe Notice 1

Table A4.0-1 Subsequent License Renewal Commitments Program Commitment

11. The Unit 1 hydrogen seal oil system deluge sprinkler pipe and Unit 1 station main transformer '1A' deluge sprinkler piping will be reconfigured to allow drainage.
12. Procedures will be revised to address recurring internal corrosion with the use of Low Frequency Electromagnetic Technique (LFET) or a similar technique on 100 feet of piping during each refueling cycle to detect changes in the pipe wall thickness. LFET screening or a similar technique will also be performed on accessible interior fire water storage tank bottoms during periodic inspections. The procedure will specify thinned areas found during the LFET screening be followed up with pipe w Fire Water 16 System program Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix A - UFSAR Supplement PageA-73 AMP Implementation Program will be implemented and inspections or tests begin 5 years before the subsequent period of extended operation.

Inspections or tests that are to be completed prior to the subsequent 82.1.16 period of extended operation are completed 6 months prior to the subsequent period of extended operation or no later than the last refueling outage prior to the subsequent period of extended operation. Change Notice 1 Page40 of97

Table A4.0-1 Subsequent License Renewal Commitments Program Commitment The External Surfaces Monitoring of Mechanical Components program is an existing condition monitoring program that will be enhanced as follows:

1. The Engineering walkdown procedure will be revised to include an item in the walkdown checklist to inspect insulation metallic jacketing for any damage that would permit in-leakage of moisture.
2. The Engineering walkdown procedure will be revised to add the following requirements:

a. Metallic Components

  • No surface imperfections, loss of wall thickness, flaking, or oxide coated surfaces
  • No blistering of protective coating
  • No evidence of leakage (for detection of cracks) on the surfaces of stainless steel. aflEklluminum and cogi;ier alloy

(>15% Zn or >8% Al} components (Revised Change Notice 1)

  • No accumulation of debris on air-side heat exchanger surfaces b. Elastomers and Flexible Polymers
  • No exposure of reinforcing fibers, mesh or underlying metal (for elastomers or flexible polymers with internal reinforcement)
  • No blistering, loss of thickness, dimensional change, or scuffing
  • No hardening of elastomeric elements as evidenced by a loss of suppleness during tactile inspection External C. Insulation Metallic Jacketing Surfaces
  • Inspect insulation metallic jacketing for any damage that would permit in-leakage of moisture.

23 Monitoring of

d. HVAC Closure Bolting Mechanical
  • Check that a sample of closure bolting that is in reach is not loose Components
3. The Engineering walkdown procedure will be revised to specify that walkdowns will be performed at a frequency not to program exceed one refueling cycle. Since some surfaces are not readily visible during both plant operations and refueling outages, the enhancement will also specify that such surfaces will be inspected when they are made accessible and at such intervals that would ensure the components' intended functions are maintained.
4. The Engineering walkdown procedure will be revised to provide non-ASME Code inspection guidance related to lighting, distance and offset for walkdown inspections. The procedure will specify adequate lighting be verified at the inspection location to detect degradation. Lighting may be permanently installed, temporary, or portable (e.g., flashlight), as appropriate. For accessible surface inspections, inspecting from a distance of two to four feet (or less) will be appropriate.

For distant surface inspections, viewing aids such as binoculars may be used. For viewing angles which may prevent adequate inspection, a viewing aid such as an inspection mirror or boroscope should be used.

5. A new procedure will be developed to specify that in each 10-year period during the subsequent period of extended operation, the minimum number of inspections is completed. A minimum of 25 inspections for cracking will be performed.

from each of the stainless steel. aflEklluminum, and copper alloy (>15% Zn or >8% Al} component populations assigned to the program every ten years. For insulated components exposed to condensation, a minimum of 25 one foot axial length sections and components for each material and environment combination will be inspected for loss of material and cracking after the insulation is removed. The new procedure will specify that the inspections focus on the components most susceptible to aging because of time in service, severity of operating conditions, and lowest design margin. (Revised Change Notice 1) Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix A - UFSAR Supplement PageA-82 AMP Implementation Program enhancements for SLR will be B2.1.23 implemented 6 months prior to the subsequent period of extended operation. Change Notice 1 Page 41 of 97

Table A4.0-1 Subsequent License Renewal Commitments Program Commitment

6. The Engineering walkdown procedure will be revised to specify that visual inspection of elastomers and flexible polymers will be supplemented by tactile inspection to detect hardening. Visual inspections will cover 100% of accessible component surfaces. The minimum surface area for tactile inspections will be at least 10% of the accessible surface area.
7. A new procedure will be developed to evaluate and project the rate of any degradation until the end of the subsequent period of extended operation or the next scheduled inspection, whichever is shorter. The inspection sampling bases (e.g.,

selection, size, frequency) will be adjusted as necessary based on the projection.

8. A new procedure will be developed to specify that, where practical, acceptance criteria are quantitative (e.g., minimum wall External thickness). For quantitative analyses, the required minimum wall thickness to meet applicable design standards will be Surfaces used. For qualitative evaluations, applicable parameters such as ductility, color, and other indicators will be addressed to Monitoring of ensure a decision is based on observed conditions.

23 Mechanical

9. A new procedure will be developed to specify that additional inspections will be performed if any sampling-based Components inspections to detect cracking in aluminum~ aREl-stainless steel, and copper alloy (>15% Zn or >8% Al} components do not program meet the acceptance criteria, unless the cause of the aging effect for each applicable material and environment is corrected by repair or replacement. There will be no fewer than five additional inspections for each inspection that did not meet acceptance criteria, or 20% of each applicable material, environment, and aging effect combination inspected, whichever is less. If any subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis will be conducted to determine the further extent of inspections required. Additional samples will be inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. The additional inspections will include inspections of components with the same material, environment, and aging effect combination at both Unit 1 and Unit 2. The additional inspections will be completed within the interval (e.g., 10-year inspection interval) in which the original inspection was conducted. (Revised Change Notice 1)

The Flux Thimble Tube Inspection program is an existing condition monitoring program that will be enhanced as follows: Flux Thimble

1. An inspection procedure will be developed specifically for flux thimble tube eddy-current inspections, rather than continuing 24 Tube Inspection to use a generic procedure for tubing inspection. The procedure will include the acceptance criterion, with the basis, for program loss of material for the inner flux thimble tube, and identify remediating actions to be implemented if the acceptance criterion is exceeded.

Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix A - UFSAR Supplement PageA-83 AMP Implementation Program enhancements for SLR will be implemented 82.1.23 6 months prior to the subsequent period of extended operation. Program enhancements for SLR will be implemented 82.1.24 6 months prior to the subsequent period of extended operation. Change Notice 1 Page42 of97

Suny Power Station, Units 1 and 2 Application for Subsequent !,.icense: Renewal Change Notice 1 ,Appendix B - Aging Mana~emenf Programs 92.1.11 Open-Cycle Cooling. Water System Program Description The Open-Cycle Cooling Water System program is an existing preventive, mitigative. condition monitoring, and performance monitoring program that manages loss of material, reduction of heat transfer, flow blockage; and cracking of the piping, piping components, and heat exchangers identified by,the Virginia Eleciricand Power Company responses to NRC GL 89'-13, "Service Water System Problems Affecting Safety.,.Related Equipment." The program ls comprised of the aging management,aspects of the Virginia Electric and Power Company response to GL 89-13 and includes: (a) surveillance and control to reduce the incidence of flow blockage problems as a result of biofouling, (b) t~sts to verify heat ~r~nsfer of safety-related heat exchahgers, (c) routine inspection and maintenance so that loss of material, corrosion, erosion, cracking, fouling, and biofouling cannot degrade the performance of systems serviced by the open~cycle cooling water system. Additionally, recurring internal corrosion (RIC} is addressed in the Corrective Action Program through design modifications that have replaced materials more susceptible to degradation in raw water with materials that are less,susceptible to degradation in raw water; This program includes enhancements to the guidance in GL 89-13 that address operating experience such that aging effects,are adequately managed. The open-cycle cooling water system includes those systems that transfer heat from safety-related systems,,structures, and components to the ultimate heat sink: as defined in GL 89-13. The guidelines of GL 89-13 are utilized for the, surveillance and control of biofoufing for the open-cycle cooling water system. Procedures provide instructions and controls for chemical,and biocide injection. Periodic sampling procedures monitor free available oxidant at heat exchangers. In addition, periodic flushing, cleanings and/or inspections are performsd for the presence of biofouling. Periodic heat transfer testing, visual inspection, and cleaning of safety-reiated heat exchangers with a heat transfer intended function,is performed in accordance with the site commitments to GL 89~1.3 to verify'heat transfer,capabilities. Additionally, safety'-related piping segments are examined (i.e. ultrasonic testing) periodic'ally to ensure that there is no significant loss of materic1I. Whr ch* could cause a loss of intended function. Routine in$pec;tions and maintenance em:;ure that corrosion, erosion,,sediment deposition, (silting}, and biofouling do not degrade the performance of safety'-related systems s~rv:iced by open-cycle cooling water. The Internal Coatings/Linings For In-Scope Piping, Piping,Components, Heat Exchangers; and Tanks program (B2.1.28) manages the aging effects of the internal surface coatings. PageB-80 Page 43 of 97

Change Notice 1 Surry Power Station, Units 1 and l Application for Subsequent License Renewal Appendix B - Agin~ Management Programs Aging effects associated with elastomers and flexible polymeric components in the open-cycle cooling water system are managed by the Inspection of Internal 'Surfac.es in Miscellaneous Piping and Ducting Components program (B2*.1.25). The Buried arid Underground Piping and Tanks program (82.1.27) manages the aging effects of external surfaces of buried and underground piping and components. The external surface of the aboveground raw water piping and heat exchangers is managed by the External Surfaces Monitoring.of Mechanical Components program 'Ce2.. 1.23), The Internal Coatings/Linings For In-Scope Piping, Piping Components, Heat Exchangers, and Tanks program (82.1.28) will manag~ the agihg effects of internal surface coatings including those of metallic surfaces coated With Carbon Fiber Reinforced Polymer that is used as a pressure boundary, NUREG-2191 Consistency The Open-Cycle Cooling Water System program is an existing program that, following enhancement, will be consistent, with exception, to NUREG:..2191, $action XI.M20, Open-Cycle Cooling Water System. Exception Summary The following program element(s) are affected: Detection of Aging Effects (Element 4)

1.

Section XI.M20 of NUREG-2191, Open-Cycle Cooling Water, indicates that testing intervals can be adjusted, to provide assurance that equipment will perform the intended function between test intervals, but should not exceed five years. The Open-Cycle Cooling Water System program takes exception to the NUREG-2191 requirement to. perform testing of the recirculation spray heat exchangers (RSHXs) at an interval not to exceed five years. Justificatl~m for ~ceptior:i: As described in the plant responses*to GL-89-13, heat transfer performance testing of the RSHXs. is not performed due to system configuration that would require significant design modifications to support such testing. Alternatively, the RSHXs are visually inspected to confirm the absence of indications of degradation. To further reduce the potential for degradation, the internal environment of the RSHX:s and the portion of the (::onnected piping that cannot be isolated from the RSHXs is. maintained in dry layup (i.e., maintained in an air environment) and the internals of the portion of the inlet piping that is not in dry layup is maintained in wet layup (i.e.* a treated water environment that has been chemically treated to maintain a basic pH) to minimize corrosion. The open-cycle cooling water side of the RSHXs are periodically flow tested and visually inspected. PageB-81 Page 44 of 97

Change Notice 1 Surry Power Station, Units ~.and 2 Application for Subsequent License Renewal Appendix B - Aging Mana~ement Programs The plant GL 89-13 responses stated that the RSHXs would be flow tested and visually inspected every fourth refueling outage (i.e., every six year's) and that the testing and inspection intervals may be modified based on the results of further te~ting. Based on the results of further testing, the RSHXs are currently flow tested and visually inspected at ari interval of eight refueling outages (i.e., every twelve years). The change in frequency to once every eight refueling outages for RSHXs flow testing and visual im?pection was evaluated by Engineering. The evaluation included a review of prior operating experience (flow testing and visual inspection results). Prior flow test results documented between 1997 and 2010 were reviewed. The test results identified little or no blockage, with the exception of a test performed in 2003. The 2003 results revealed 5% blockage, which wai;, still less than the 10% blockage acceptance criteria. RSHXs service water inlet and outlet piping cleaning and inspection, are performed on a frequency consistent with RSHXs flow testing. A review of prior piping inspection results between 1996 and 2014 showed the piping to be in satisfactory condition. Although coating defects and areas of corrosion were identified during the piping inspections, the RSHXs were capable of performing their intended function. Required coating and weld repairs were entered in the Corrective Action Program. Enhancements Prior to the subsequent period of extended operation, the following enhancement(s) will be implemented in the following program element(s): Preventive Actions (Element 2) 1.. Selected fiberglass reinforced plastic (FRP) piping in the service water system will be replaGed' with a more degradation resistant material such as copper-niokel (Cu-Ni) prior to entering the subsequent period of extended operation. FRP piping associated with the* Units 1 and 2 charging p<Jmp cooling water subsystems, service water rotating strainers, and the control room chillers may* be replaced,as part of a time-phased program.

2.

Modifications neces$ary to provid~ new chemical injection site upstream of the service water rotating strainers will be completed prior to entering the subsequ.ent period of ex_tendecJ operation.

3.

The internal lining *of 24 inch and larger service water inlet piping with carbon fiber reinforced polymer, with.the exception of the recirculation spray heat exch~nger piping downstream of the inlet motor-operated valves, will be completed prior to entering the subs.equent period of extended operation. P~geB-82 Page 45 of 97

Change Notice 1 Parameters Monitored and Inspected (Element 3) .Suny Power Station. Units 1 *and 2 Application for Subsequent License Renewal .Appendix B.. Aging. Management Programs 4,. PFesodui:es will be Fei.iiseeUe FOme*,e Feforef!oe ta th~el 13ipiAg that v.*as roplacea eAd 'Nill inskfffe the replasefflent R'lelteFial.

5.

Procedures will be revised to provide additional guidance for identifying and evaluating app,icable concrete aging effects such as toss of material due to delamination, exfoliation, spalling, popout, scaling, or cavitation; and cracking due to chemical reaction, or corrosion of reinforcement. Detection. of Aging Effects (Element 4}

6.

Procedures will be revised to require personnel who perform inspections and evaluation of concrete components to be qualified consistent with the qualifications identified in the Structures Monitoring program (82.1.34) that, are consistent with the requirements of ACI 349.3R. Monitoring and Trending (Element 5)

7.

Procedures. will be revised to require trending of charging pump lube oil cooler and emergency service water pump engine heat exchanger inspection results by Engineering.

8.

Procedures will be revised to require trending of wall thickness measurements. The frequency and number of wall thickness measurements will be based on trending results, Acceptance Criteria (Element 6) 9: Procedures will be revised.to include verification that predicted wall thicknesses at the,next scheduled inspection will be greater than the minimum wall thicknesses.

10. Procedures will be revised to include criteria, for the extent and rate of on-going degradation that Will prompt additional corrective actions.
11. Procedures will be revised to identify acceptance criteria for visual inspection of concrete piping and components such* as the absence of cracking and loss* of material, provided that minor cracking and loss of mat~rial in concrete may be acceptable where there is no evidence of leakage, exposed rebar or reinforcina "hoop" bands or rust staining from such reinforcing elements.

Corrective Actions (Element 7)

12. Procedures will be revised to ensure that for ongoing degradation mechanisms (e.g., MIC), the*

frequency.and extent of wall thickness inspections at susceptible locations are increased commensurate with the significance of the degradation. P~geB-83 Page 46 of 97

Change_ Notice 1 Surry Power Station, Units 1 ancJ 2 Application for Subsequent License Ren~!. Appendix B - Aging Management Programs

13. Procedures will *be revised to ensure that when measured parameters do not meet the acceptance criteria, additional inspections are performed, when the cause of the aging effect is not corrected by repair or replacement for components with the same material and environment combination. The number of inspections will be determined by the Corrective Action Program, but no fewer than five additional inspections will be performed for each inspection that did not m~et th~ acceptance criteria, or 20% of the applicable material, environment, and aging effect combination inspected, whichever is less. The additional inspections will include inspections at both Unit 1 and Unit 2 with the same material, environment, and aging effect combination.

Operating Experience Summary The following examples of operating experience provide objective evidence that the Open-Cycle Coo/inf! Water System program has been, and will be effective in managing the aging effects for SSCs within the scope of the program so that their intended functions will be maintained consistent with the current licensing basis during the subsequent period of extended operation.

1.

In September 2001, a through wall leak was identified in an eight inch carbon steel control room chiller service water supply line. A through wall leak in similar piping occurred again,in September 2005. In May 2006, volumetric inspections measurements identified a location in an eight inch carbon steel control room chiller service water supply line that was less than the minimum allowable wall thickness. A design change was implemented, which replaced the eight inch carbon steel piping with copper-nickel piping.

2.

Between August 2001 and July 2009, biofouling of the control room chillers Y-strainers and rotating strainers occurred on multiple occasions. The initial cause was thought to be insufficient backwash flow to the rotatii19 strainers during periods of elevated service water temperatures with one control room chiller operating. Procedure changes were implemented to start an additional pump and backwash the rotating strainers when differential pressure reaches one psid. Further clogging of the Y-straihers resulted in compensatory.actions being established. These measures included increased monitoring -of control room chiller and servlce water operating parameters when service water temperature was greater than 80°F, weekly flushing of control room chiller service water iines, and securing the chiller and cleaning the chiller suction strainers when pump suction pressure approached the minimum required net positive suction head. PageB-84 Page 47 of 97

Change Notice 1 Su,:_ry Power Station, Units 1. and 2 Application for Subsequent License Renewal Appendix B - Agrng Management Program*s In July 2009, repeated clogging of the control chiller.suqtion Y-strainers occurred, Additional compensatory measures included more 'frequent flushing ofthe control ro<;>m chiller service water piping,.and running.a minimum of two control room chillers to minimizf? system transients, which was determined to exacerbate biofouling of the strainers. In the fall. of 2009, a modification was completed that provided additional chemical (biocide) injection into the service water system downstream of the* rotating strainers and upstream of the Y-strainers to control biofouling. Chemical injection has. proven effective in red.ucing 'biefoul,ing of the Y-strainers and associated piping.

3.

In October 2009, following sampling of the service water side of the component cooling heat. exchangers, chemistry personnel determined the free available oxidant (FAQ) readings were below minimum acceptable values, which could jeopardize control of biofouling in the syst~m. The* chemical injection pump settings were adjusted to restore the pump discharge pressure. Samples taken following adjustmehts revealed that the FAO levels were acceptable:

4.

In.February 2010, au~rnented volumetric inspections of the component' cooling heat exchanger service water supply and discharge piping identified piping wall thicknesses that were less than minimum allowed. A weld repair was performed and the calculation.of record was updated to reflect the: results of the wall thickness readings. Pipe stresses wer:e determined to* be within code allowable..Subseq!,Jent wall thickness measurements taken following repairs were acceptable.

5.

In January 2012, during the performance of a license renewal inspection of a comporient cooling heat exchanger; pitting, defective coatings, barnacles, and river debris were identified in the heat exchanger. Corrective actions included replacement of a manway, removal,of debris from the heat exchanger, coating repairs, and performance of a weld repair. 'Inspections performed in April '2013 and* February 2016 also identified needed weld repairs to the heat exchanger end bell. A surface examination and *system pressure test were *performed satisfactorily following weld repairs.

6.

In October 2013, during surface preparation and weld inspections, a through wall leak was observed in the 4?.inch service water piping.adjacent to the motor-operated valve supplying service water to the component cooling water heat exchangers from the '1 B' condenser water box tunnel. The cause of pipe wall thinning was determineo to be non,.application of the pipe internal coating.. Historicaily, the motor-operated valve exhibited seat leakage since original installation. In an effort to control leakage, a blank and a hose were used to divert the le~kage. As a result, the piping at the blank was unable to be properly coated. Over time, the lack of coating resulted in significant wall loss. Corrective actions included replacement of the valve wit'1 a design which woulcl minimize valve leakage, weld repairs to the piping, and internal coating of,the piping.. A post-weld surface examination and system pressure test were performed satisfactorily. PageB-85 Page 48 of 97

Change Notice 1 Suny Power Station, Units. 1 and 2. Application for Subsequent License Renewal Appendix B -Aging Management Programs

7.

In November 2013, three through waif *leaks were identified in the 42 inch piping.upstream of the motor-operated -valve supplying service water to the component cooffng water heat .exchangers from the '1 D' condenser water box tunnel. The leaks were identified following sand blasting of the piping in preparation for application of internal coating. Weld repairs were performed to correct the deficiencies. A surface examination and system pressure test were performed satisfactorily subsequent to the repairs.

8.

Between September 2015 and September 2016, five leaks occurred ih the service water syst_em due to cracking of fiberglass piping. The leaks were either repaired or new piping segments installed in accordance with the work order process. The fiberglass piping in the service water system may be replaced with corrosion resistant material such as copper-nickel as part of a time-phased program.

9.

In December 2015, an ~ffectiveness review of the Service Water System Inspections Activity (UFSAR Section 18.2.17) was performed. The aging management activity (AMA) was evaluated against the performance criteria identified in NEI 14-12 for the Detection of AginQ Effects, Corrective Actions, and Operating Experience program elements. No gaps were identified by the effectiveness review.

10. In December 2016, as part of oversight review activities, a review of procedure$ credited by initial license renewal AMA was conducted to confirm the following:
  • Procedure~ credited for license renewal were identified
  • Procedures were consistent with the licensing basis and bases documents
  • Procedures contained a reference to conduct an aging management review prior to revising
  • Procedures credited for license renewal were identified by an* appropriate program indicator and contained a reference to a license renewal document Pro9edure changes were.completed as necessary to ensure the above items were satisfied.
11. In September 2017, as part of oversight activities, of the Service Water Inspections Activity

(.UFSAR Section 18.2.17) it was noted that commitments fdr the low level intake screenw~II (LLIS) and emergency service water punip suction end bell cleaning/inspections were not being_ performed and documented consistent with the original License Renewai commitment. The License Renewal commitments for the LLIS cleaning and' pump inspections were originally incorporated into the procedure that dewatered the LLIS. The recent license renewal cleaning/inspections were performed by divers using a *recurring work activity without dewatering the LLI S. A corrective action was initiated for engineering ~nd outage planning to resolve the inconsistency. It.was determined that the cleaning and inspection commitments were satisfactorily completed without dewatering the LUS. Update of the maintenance strategy and associated documents to allow performance of the license renewal commitments with or without dewatering the LLIS is in progress. PageB-86 Page 49 of 97

Change Notice 1 Surry Powef StatiQn, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

12. In January 2018, an aging management program effectiveness review was performed for the Service Water 'System Inspections Activity (UFSAR Section 18.2.17). Information from the summary of that' effectiveness review is provided below:

The Service Water System Inspections Activity is meeting or exceeding the requirements of selected NEI 14-12', "Aging Management Program Effectiveness," elements. Key activities of the AMA that were reviewed include the selection of components to be inspected, the inspection of components, the evaluation of inspection results, repairs/replacements, anti AMA document updates. Engineering reports from 2004 to 2016 of inspections results were reviewed to confirm inspection frequencies were conducted at appropriate intervals and corrective actions taken consistent with the observed aging degradation. The review also included pertinent issues found in the Corrective Action Program from 2006 through 2017 for age related degradation of open,.cycle cooling water system components within the scope of license renewal. The key aspects of the Open-Cycle Cooling Water System program involve controlling biofouling, testing critical heat exchangers, inspecting and cleaning the system, and designing with robust materials. The program is implemented using an active Service Water System Inspection and Maintenance Program and. has a well-established Generic Letter 89-13 Program. These programs govern the approach to compliance with the Nuclear Regulatory Commission (NRG) Generic Letter 89-13, Service Water Problems Affecting Safety-Related Equipment. The Program.is.inspected every three years l;>y the NRC using Inspection Procedure 71111.07, Heat Sink Performance. The most recent inspection did not identify any findings. Additionally, station effectiveness is assessed by implementing INPO SOER 07-2, Intake Cooling Wate*r Blockage every three years. The assessment reviews operating experience, condition reports, and equipment performance for the three year period. The most recent assessment, completed in September 2016, concluded that open-cycle cooling water equipment has* been performing satisfactorily. Over the summers of 2007 through 2009, a series of events involving an influx of biological growth from the James River prompted the creation ofthe Service Water Excellence Plan. The plan has resulted in numerous improvements designed to greatly reduce the adverse effects of biofoufing and aging. For example, a biocide injection system has been installed to reduce biological growth, key pieces of safety-related piping have.been convertiad to corrosion and fouling resistant materials, and new monitoring and flushing procedures have been instituted> More recently, since entering the first period of extended operation, the interior of the large diameter open-cycle cooling water piping has begun to be lined with carbon fiber reinforced polymer (CFRP). Surry Power Station is first in the industry to employ this technology. It is predicted that the CFRP will *add 50 years of effective service life to the ass.et. The biocide injection point on the safety-related service water piping will also be relocated to maximize effectiveness. PageB-87 Page 50 of 97

Change Notice 1 Recurring Internal Corrosion (RIC) Surry :Pqwer Statton, Units 1 ~nct 2 Application for Subsequent License Renewal Appendi?{ B - Aging Management Programs Recurring in.temal corrosion, including through-wall failures due to pitting and internal fouling of components, has occurred on several occasions. Corrective actions have been taken previously, and additional aptions are scheduled to minimize* the likelihood of piping and component degra(:fation due to flow blockage and loss of material in the open-cycle cooling water system. The physical modifications: completed or,scheduled, and enhancements to operating practices and system design to improve OCCW system resistance to recurrence of internal corrosion, are noted below: The Open-Cycle Cooling Water (,OCCW) System progr:ami will manage,aspects of RIC in the service water system and the circulating water system tnat are within \\he scope of the program. The Internal Coating$1Unings For In-Scope Piping, Piping Components, Heat Exchangers, and Tanks program (82.1.28) will manage lo~s of material on the internal surfaces,of service water system and circulating water system piping that has been lined or coated, The ln'$pection of Internal Surfaces in Miscellanec;,us Piping and Ducting Components prc;,gram (B2.1.25) will manage loss of material on the internal surfaces of service water system and circulating water system piping not covered by NRC Generic Letter 89-13. Flow Blockage: Flow blockage in OCCW system piping and components is managed by periodically monitoring control room chiller Y-strainer differential pressure and perioi;tically flushing affected piping flow paths. During times when service water temperatures are elevated, above aoaF, the operations surveillance frequency of monitoring service water suction pressure and rotating strainer differential pressures are increased. to intervals as short once every 4 hours and piping flush frequency increased to once daily. As a preventive measure, biocide injection points have been added downstream of the rotating suction strainers and the biocide injection has *significantly reduced hydroid attachment and growth. A plant modification is in progress to add additional injection points to the UP.stream portion of the service water rotating strainers. Loss of Materiai in Unco~ted Steel Piping: t..oss of. material has resulted in recurrent wall thinning and through wall leakage in service water piping in uncoated steel service water piping associated with main. control room chillers. Repfacement of 1.,mcoated steel piping with corrosion resistant copper-nickel piping reduced the susceptibilfty of the OCCW systems, to recurring internal corrosion. There has been no documented recurring internal corrosion on the control room chillers copper-nickel piping m other copper-nickel i;;ervice water system piping within the scope of subsequent license renewal. Pages~as Page 51 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 * .Application for Subsequent Ucense Renewal* Appendix B - Aging Management Prag.rams Loss of Material in Copper-Nickel Alloy Heat Exchanger Tubing: Recurring internal corrosion (loss of material) was experienced in the copper-nickel alloy heat exchanger tubing at and beyond the tube sheet for the main control roo1.11 chiller condensers, including a condenser that had been recently replaced. The affected heat exchanger components have been cleaned and coated with a protective epoxy coating with the coating extending six inches into the heat exchange tubes. The Corrective Action Program apparent cause evaluation identified that the heat exchanger management program did not require flow to be maintained for an extended periOd in new 90-10 copper-nickel alloy heat exchangers to permit a protective oxide film to form on the tubes*. prior to the placement of the heat exchangers into a stagnant wet lay-up condition. Implementing documents have been modified to incorporate this lesson:-learned. After epoxy coating and modification of wet layup practices, there has been no documented recurring internal corrosion in the control room chiller condenser copper-nickel alloy tubing at and beyond the tube sheet. Loss of Material in Coated Steel Piping and Heat Exchanger Channel Heads: Corrosion-resistant Carbon. Fiber Reinforced Polymer (CFRP) liner will be installed in the 96-inch circulating water inlet piping, and 24-, 30'-, 36-, 42-, and 48-inch service water supply from the circulating water SYl?tem-to the recirculation spray and supply to the c*omponent cooling water heat exchangers. The CFRP system is designed to take the place of the existing carbon steel pipe and will form a repaired pipe within the existing piping that is capable of meeting the design requirements of the station piping. The appropriate relief has been granted for this repair by the NRC. The Internal Coatings/Linings For ln-Scop'e Piping, Piping Components, Heat Exchangers.. and Tanks program (82.1.28) will manage the aging of CFRP in the OCCW systems. For epoxy coated piping sections and heat exchanger channel heads that do not yet have the CFRP lining installed, the Internal Coatings/Linings For ln*Scope Piping, Piping Components, Heat Exchangers, and Tanks program (B2.1.28) will manage the aging of th~ existing epoxy-coated steel piping. 1he above examples of operating: experience provide objective evidence that the Open-Cycle Cooling Water System program includes activities to perform surveillance and control, heat exchanger testing, and* routine inspection and maintenance to. identify loss of material, reduction of heat transfer, flow blockage, ~nd craoking of the piping, piping components, and,heat exchangers within the scope of subsequent license renewal, as identified by the Virginia Electric and Power Company responses to NRC GL 89-13, and to initiate corrective actions. Occurrences identified under the Open-Cycle Cooling Water System program are evaluated to ensure there is no significant impact to the safe operc1tion of the plant and corrective actions will be taken to prevent recurrem;:e. Guidance or corrective actions for additional inspections, re-evaluation, repairs, or replacements is provided for locations where aging effects are found. The program is informed and enhancec;t when necessary through the systematic and ongoing review of both plant-specific and PageB-89 Page 52 of 97

Cliahge Notice 1 Surry Power Station, Units 1 an,;f ~' Application for Subsequent License Renewal Appendix B - Aging Management Programs industry operating experience. There*is reasonable assurance that the continued implementation of the Ope_n.;Cycle Cooling Water System program, following enhancement, will effectively manage aging prior to loss of intended function. Conclusion The continued implementation of the Open-Cycle Cooling Water System program, following enhanc~ment, provides rea$onable assurance that aging effects will be managed such that ~he components within the scope of this program will continue to perform their intended functions

  • consistent with the current licensing basis for the subsequent period of extended operation.

PageB-90 Page 53 of 97

Surry Power Station; Units 1 and 2 Application for Subsequent License Renewal Change Notice 1 Appendix B - Aging Management Programs B2.1.1S Fire Water System Program Description The Fire Water System program is an existing condition monitoring program that manages toss of material, flow blockage, and loss of coating integrity for in-scope water-based fire protection systems. This program manages aging effects by conducting periodic visual inspections, flow testing, and flushes. Testing and inspections are conducted on a refueling outage interval as allowed by NUREG-2191, Section XI.M27. Table XI.M27.. 1. "Fire Water System Inspection and Testing Recommendations". There are no nozzle strainers, glass bulb sprinklers. fire pump suction strainers. or foani water sprinkler systems within the scope ofsubsequent license renewal. The flre Water System program will include testing a representative sample of the sprinklers prior to fifty years in service with additional representative samples tested at 10-year Intervals. Sprinkler testing will be performed consistent with the 2011 Edition of NFPA 25, "Standard For The Inspection, Testing and Maintenance of Water-Based Fire Protection Systems," Section 5.3.1. The fifty year in-service date for sprinklers is October 26, 2021. Portions of water-based fire pr9tection system components that have been wetted, but are normally dry, such as dry-pipe or preaction sprinkler system piping and valves, were designed and installed with a configuration and pitch to allow draining. With the exception of two locations, Engineering walkdowns confirmed the.;is-built configuration that.;illows draining and does not allow water to collect. Corrective actions have been initiated for the two locations to verify a flow blockage condition does not exist and to restore the two locations to original configuration requirements that allow draining and do not allow water to collect. After corrective actions, portions of the water-based fire protection system that have been wetted, but are normally dry. will not be subjected to augmented testing and inspections beyond those required by NUREG-2191, AMP XI.M27, Table XI.M27-1. The water-based fire protection system is normally maintained at required operating pressure and is monitored such that loss of system. pressure is detected and corrective actions initiated. A low pressure condition is alarmed in the Main Control Room by the auto start of the electric motor driven fire pump, followed by the start of the diesel,-dtiven fire pump if the low pressure condition continues to exist. The status of the fire pumps is indicated in the Main Control Room and at the fire pump control panels in the pump house. Both fire pumps may be manually started from the control room. Piping wall thickness measurements are conducted when visual inspections detect surface irregularities indicative of unexpected levels of degradation. When the presence of organic or inorganic material sufficient to obstruct piping or sprinklers is detected, the material is removed and the source is detected.and corrected. PageB-108 Page 54 of 97

Change Notice 1 Surry Power station, Units 1 and' 2 Applieation for Subsequent License Renew1:1f Appendix B - Aging Management Programs Inspections and tests are performed by personnel qualified in accorqance. with procedures and. programs* to perform the specified task. Non-code inspections and tests follow procedures that include inspection parameters for items such as lighting, distance, offset, presence of protective coatings, and cleaning processes that ensure an adequate examination. If a flow test (I.e.. NFPA 25, 2011' Edition. Section 6.3.1) or a main drain test (i.e., NFPA 25, 2011 Edition, Section 13. 2.5) does not meet the acceptance criteria due to current or projected* degradation, additional tests are conducted. The number 9f increased tests is determined in accordance with the site's corrective action process; however, there are no.fewer than two additional tests fat each test that did not meet the acceptance criteria. The additional inspections .are completed within the interval (i.e., five years or annual/refueling) in which the original test was conducted. If subsequent tests do* not meet the.ac;:c~ptance criteria, an extent of condition,;1nd extent of cause analysis is conducted to determine the further extent of tests required. The additional tests will include at least one test at the other unit on site with the;? same material, environment, and aging effect combination. In addition to piping replacement. actions will be taken to address instances of recurring corrosion due to microbiological induced corrosion. Low Frequency Electromagnetic Technique (LFET) or similar scant1ing technique will be used*for screening 100 feet of accessible piping during each refueling cycle to detect changes in" the wall thickness of the pipe. Thinned areas found during the LFET scan are followed up with pipe wall thickness examinations to ensure aging ~ffects are managed and that wall thickness is within acceptable limits. In additien to.the pipe'wall thickness examination. opportunistic visual inspections of the fire protection system will be performed whenever the fire water system *is opened for maintenance. Aging of the *external surfaces of buried and underground fire main pipin~ is managed by the Buried and Underground Piping and Tanks program (82.1'.27). Loss of material and cracking of the internal surfaces of cement lined buried and underground fire main piping are managed by the Internal Coatings/Linings 'For ln-S.cope Piping, Piping Components,. Heat Exchangers, and Tanle Fe*,iseEI te req1::lir:e replaoeR'!eRt of any sprinkleF-tl=lat shews any---ef-t~e foUe1,.Ving: leal<age, seFFOsion, physisal Elamage, leaeHng, paiAt-iRg unless 13ainteel by the sf;)r-inldor man~faall:JFer, eF ineerreot orieRtation. Sp~nlders at tl:10 following _ taeatieffs-wUl-ee added te tf:le test seope: The Raawaste Faoilil:y, Au)dliary Boiler, Maintenance -Bwleli-Ag, Gendensate Pelishing Building, Laundry Building, af!d MaoAine Shop Building.

2.

Prior to 50 years in seivice, sprinkler heads will be submitted for field-service testing by a recognized te$ting laboratory consistentwith NFPA 25, 2011 Edition, Section 5.3.1. Additional repr~sentative samples will be field-service tested every 1 O years thereafter to ensure signs of aging are detected in a timely manner. For wet pipe sprinkler systems, a one-time test of sprinklers that have been exposed to water including the sample size, sample selection criteria, and minimum time in service of tested sprinklers will be performed.

3.

Procedures will be revised to specify:

a. Standpipe and system flow tests for hose stations at the hydraulically most limiting locations for each zone of the system on a five year interval to demonstrate the capability to provide the design pressure at required flow.
b. Acceptance criteria for wet pipe main drain tests. Flowing pressures from test to test will be monitored to determine if there is a 10% reduction in full flow pressure when compared to previously performed tests. The Corrective Action Program will determine the cause and necessary corrective action.
c. If a flow test or a main drain test does not meet acceptance criteria due to current or projected degradation additional tests are conducted*. The number of increased tests is determined in accordance with the corrective action process; however, there are no fewer than two additional tests for each test that did not meet acceptance criteria. The additional inspections are completed within the interval in which the original test was conducted. If subsequent tests do not meet acceptance criteria, an extent of condition and extent of cause analysis is conducted to determine the further extent of tests. The additional tests include at least one test at the other unit with the same material, environment, and aging effect combination.
d. Main drains for the standpipes associated with hose stations within the scope of subsequent license renewal will also be a<;lded to main drain testing procedures.

PageB-111 Page 57 of 97

Change Notice 1 Surry Power station. Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs Parameters Monitored or Inspected (Element 3), Detection of Aging Effects (Element 4), and Monitoring and Trending (Element 5)

4.

Procedures will be revised to perform system flow testing at flows representative of those expected during a fire. A flow resistance factor (C-factor) will be calculated to compare and trend the friction loss characteristics to the results from previous flow tests. Parameters Monitored or Inspected (Element 3) and Detection of Aging Effects (Element 4) e:- Procedures fer hydrant fl1:1sl:liRg will l=Je reviseel to requiro fully or;ening the f:lydrant anel fully ffe*.ving U1e hydraAt fer na less tl~an one minute and l:!ntil f-erei0n material has cleared. In addition, prooed1:1res will be re*,:isee-{o-eesorve dFaining of tl!\\e hyelront ~arrol anel alse roq1:1ire U~e barrel 13e pumped dry should it not drain witf:l+A-00-minutes. Hydrants outside the 13r0tested area tt:1at are within tf:le ssope of suese~e asdeel to tl!le-flHsh ssepe.

6.

The Fire Water System program will be revised to periodically inspect the insulated exterior surfaces of the fire water tanks on a 10-year frequency during the subsequent period of operation. Insulation is removed to provide a minimum inspection population of 25 one-square foot samples. The samples will be distributed in such a way that inspections occur on the tank dome, near the tank bottom. at points where structural supports, pipe, or instrument nozzles penetrate the insulation and where water could collect. In addition, inspection locations will be based on the likelihood of corrosion under insulation occurring. +: Procedures for mainline strainer-flushing will be FCVised to reeiuire flushing until sleaf watef:..<<; obsewed after eaoh operation or Jlow test. In addition to tl~shing after operotion. the RaEi'.vaste Facility mainline straffler will FeE!UiFC an ins~olion evei=y five yearo for daFRageel-aAd oorrodee ~

8.

A procedure will be created to provide a Turbine Building oil deluge systems spray nozzle air flow test to ensure that patterns are not impeded by plugged nozzles, to ensure that nozzles are correctly positioned, and to ensure that obstructions do not prevent discharge patterns from wetting surfaces to be protected. PageB-112 Page 58 of 97

Change Notice 1 Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

9.

Procedures will be revised to perform internal visual inspections of sprinkler and deluge system piping to identify internal corrosion, foreign material, and obstructions to flow. Follow-up volumetric examinations will be performed if internal visual inspections detect an unexpected level of degradation due to corrosion product deposition. If organic or foreign material, or internal flow blockage that could result in failure of system function is identified, then an obstruction investigation will be performed within the Corrective Action Program that includes removal of the material, an extent of condition determination, review for increased inspections, extent of follow-up examinations, and a flush in accord~nce with NFPA 25, 2011 Edition, Annex D.5, Flushing Procedures. The internal visual inspections will consist of the following:

a.

Wet pipe sprinkler systems - 50% of the wet pipe sprinkler systems in scope for subsequent license renewal will have visual internal inspections of piping by removing a hydraulically remote sprinkler, performed every five years, consistent with NFPA 25, 2011 Edition, Section 14.2. During the next five-year inspection period, the alternate systems previously not inspected shall be inspected.

b.

Pre-action sprinkler systems - pre-action sprinkler systems in scope for subsequent license renewal will have visual internal inspections of piping by removing a hydraulically remote nozzle, performed every five years, consistent with NFPA 25, 2011 Edition, Section 14.2.

c.

Deluge systems - deluge *systems in scope for subsequent license renewal Will have visual internal inspections of piping by removing a hydraulically remote nozzle, performed every five years, consistent with NFPA 25, 2011 Edition, Section 14.2. Detection of Aging Effects (Element4).

10. Procedure will be revised to provide inspection guidance related to lighting, distance and offset for non-ASME Code inspections. The procedure will specify adequate lighting be verified at the inspection location to detect degradation. Lighting may be permanently installed, temporary, or portable (e.g., flashlight), as appropriate. For accessible surface inspections, inspecting from a distance of two to four feet (or less) will be appropriate. For distant surface inspections, viewing aids such as binoculars may be used. For viewing angles which may prevent adequate inspection, a viewing aid such as an inspection mirror or boroscope should be used.
11. The Unit 1 hydrogen seal oil system deluge sprinkler pipe and Unit 1 station main transformer

'1A' deluge sprinkler piping will be reconfigured to allow drainage. PageB-113 Page 59 of 97

Change Notice 1 Surry P<;>wer Station, Units 1 and 2 Application for Subsequent L_icense Renewal Appendix 8 - Aging Management Programs Detection of Aging Effects (Element4) and Acceptance Criteria (Element 6)

12. Procedures will be revised to address recurring internal con:osi~n with the use of Low Frequency Electromagnetic Technique (LFET) or a similar technique on 100 feet of piping*

during each refueling cycle to detect changes in the pipe wall thickness. LFET screening or a similar technique will also be performed on accessible interior fire water storage tank bottoms during periodic inspections. Tlie procedure will specify thinned areas found during the LFET screening be followed up with pipe wall thickness examinations to ~nsure aging effects are managed and wall thickness is within acceptable limits. In addition to the pipe wall thickness examination, the performance of opportunistic visual inspections of the fire protection system will be required whenever the fire water system is opened for maintenance. Operating Experience Summary The following examples of operating experience provide objective evidence that the Fire Water System program has been, and will be effective in managing the aging effects for SSCs within* the scope of the program so that their intended functions will be maintained consistent with the current licensing basis during the subsequent period of extended operation.

1.

In January 2012, an Engineering walkdown of the fire protection piping header along the north wall of the Unit 2 Turbine Building revealed a potential leak location on the supply line to a hose rack. The flanged connection and straight pipe were removed and replaced.

2.

In January 2012, a section of 2~inch fire protection "drop" piping in the Turbine Building developed -a leak. The investigation for extent of condition and determination for the extent of fire protection piping to be inspected and replaced, as necessary, involved inspections of three locations in the Turbine Building and three locations in the Auxiliary Building. Microbiologically induced corrosion (MIC) was evident in many locations, but the extent of corrosion was not as severe in the Auxiliary Building as it was in the Turbine Building. Despite the less severe corrosion in the Auxiliary Building, the three segments of piping that were inspected were* replaced. ~imilarly, one of the three segment~ -of piping in the Turbine Building was replaced. A capital prqject was proposed for a multi-year process of replacing segments of 2-inch, 4-inch, and 10-inch piping in the Turbine Building. The initial phase that was completed incl.uded replacing 200 feet of ten inch piping *111 the Turbine Building. Additional phases were proposed, and described in the Fire Prote.ction Strategic Plan. See April 2013 and* November 2015 operating experience.

3.

In June 2012, during inspection of Auxiliary Building fire protection piping minor sediment was discovered in the supply header to the Uriit 1 cable tunnel sprinklers. Debris and MIC nodules were discovered inside a spool piece and accessible four inch piping. The SE;ldiment and debris were removed, the visual inspection was*performed, and the blind flanges and spool pieces were replaced. The necessary pipe replacemenris included in the Fire Protection strategic Plan~ PageB-114 Page 60 of 97

Change Notice 1 Surry Power Station; Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

4.

In March 2013, NRC lnfonnation Notice 13-06, "Corrosion in Fire Protection Piping Due to Air and Water Interaction", identified industry operating experience involving the loss offunction of fire protection water systems due to the potential for adverse air.and water interactions in pre-action and dry.:.pipe systems. Engineering evaluated the potential for similar adverse conditions and associated degradation in deluge systems at Surry Power Station that are periodically flow tested. Subsequently, in January 2018, a walkdown was performed to confirm that plant design specifications on drainage features fo'r piping downstream of all in-scope pre-action and deluge valves in the fire protection system continued to be in effect. Two locations, one relating to main transformer 1A and one relating to Unit 1 generator hydrogen seal oil system, were identified as having a potential for adverse air and water interactions and entered into the corrective action program.

5.

In April 2013, a section of two 10-inch fire protection system piping in the Turbine Building developed a leak. A walkdown of six locations was perfom,ed to determine extent of condition in the Turbine Building and the Auxiliary Building. MIC was evident in four locations, but the extent of corrosion in the Auxiliary Building was not as severe. Replacement of 4-inch and 10-inch fire protection header is a like-for-like replacement. The replacement of the Turbine Fire Protection Header was split into four different phases. One phase was to be accomplished each year. The second phase is planned to replace approximately 400 feet of ten-inch header pipe and 200 feet of two-inch hose station pipe. The necessary pipe replacement is included in the Fire Protection Strategic Plan.

6.

In February 2014, visual and volumetric inspections were performed for Fire Protection/domestic water storage tank 1 A to determine the extent of additional degradation that had o*ccutred since similc;lr inspections were completed in December 2008. The most significant degradation was noted on the tank floor. The result of the visual inspection was that coating de1;1radation was continuing, and that some bare metal was evident. Similarly, volumetric examinations found additional thinning for the tank floor. An engineering evaluation project~d that the tank floor plate would reach minimum. acceptable thickness prior to the expiration of the Unit 2 renewed operating license. Monitoring of the* tank floor will continue until the tank floor is repaired or replaced. The necessary tank repair or replacement is included in the Fire Protection Strategic Plan.

7.

In August 2014, visuarand volum~tric inspectionswere performed for Fire Protection/domestic water storage tank 1 B to determine the extent of additional degradation that had occurred since similar inspections were completed in December 2008. The most significant degradation was noted on the tank floor. The result of the visual inspection was that coating degradation was continuing, and that some bare metal was.evident. Volumetric examinations found some thinning of the tank floor. An engineering evaluation projected that the tank floor plate would reach minimum acceptable thickness prior to the expiration of the Unit 2 renewed operating license. Monitoring of the tank floor will con~inue until the tank floor is repaired or replaced. PageB-115 Page 61 of 97

Change Nptice 1 Surry 'Power Station; Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

8.

In Septemb~r2014, a materials analysis was performed<?" buried cement iined grey cast,iron. fire main piping that was fractured during flow t~sting.of hose station valves. The fracture was attributed to.a latent material defect *in the cast iron. The piping was removed and replaced with an equivalent spool piece. Based on the oxidation along the top segment of the:crack, the pipe was cracked for a long period of time. High levels. of calcium depo~its on the.fracture (from the cement lining) indicate that the pipe was partially cracked at the top segment before factofy installation.of the cement liner (manufacturing process). Material analysis of the pipe determined that the microstructure consisted of graphite.flakes that were approximately 75% ferrite anq 25% pearlite. This.resulted in a reduction in the supplied material hardness. Failure of pipe was not preventable through maintenance. The failu*re was* caused by* ground settling. During the pipe replacement it was observed that there was vertical misalignment between the replacement pipe and the existing buried pipe, which indicated that the buried side piping was exerting a large bending *load at the anchor/foundation. This bendi'ng lo;:1d along with the* pre-existing crack and lower hardness value caused the pipe fracture. The balance of the failed pipe was found in good condition with no significant loss of cement lining material, corrosion, cracking, fouling, or reduction of pipe interior diameter.

9.

In November 2015, an effectiveness review of the Fire Protection Program aging* management activity (AMA) (UFSAR Section 18.2. 7) was performed. The AMA was evaluated against the performance criteria identified in NEI 14-12 for the Detection of. Ai;Jing Effects. Corrective Acti_ons, and Operating Experience program elements. A comprehensive fire water system assessment recommended a large scale piping replacement of turbine building and auxiliary building piping. The large scale piping replacement project to be pelformed over multiple refueling outages was identified as a measure to address degradation.in carbon steel system pipiag and to ensure that system.intended functions were maintained. *completed and closed phases of this effort have included replacement of approximately 400 feet of 4 inch piping and 200 feet of 2* inch piping in 2014 and approximately 567 feet of 4 Jhch,piping and 303 feet.of 2 inch piping in 2015. An additional phase replacing approximately 175 feet of 4 inch piping and 100 feet cif 2 inch piping has been completed and is awaiting final testing. Work documents for additional phases are planned and issued for wo.rk extending into 2019.

10. In April 2016, results :from. fire protection $ystem flow tests with the motor driven fire pump in April 2016, July 2013, and April 2010 consistently showed that the system pressure is higher than the required value for the eorrespondirig flow rate. In 2016, the result indicated that the measured pressure excee.ded the required pressure by fourteen psi. In 2013, the measured pressure was thirteen psi higher than required. The result in 201 O measured a pressure that was 19 psi higher than required. The trend from these results does not indicate significant degradation over tfle six-year interval, particularly considering the two most recent me~surements. There is confidence that continued implementation of flow monitoring for the fire protection system using the three year interval required by the Technical Requirements Manual will effectively manage aging prior to a loss of intended function.

PageB-116 Page 62 of 97

Change Notice 1 Surry Power Station, Units 1 and i Application for Subsequent license,Ren!;3wal Appendix B -Aging Management Programs

11. In December 20*16; as part of oversight review activities,, a review of procedures credited 'by initial license renewal AMAs* was conducted to confirm the following:
  • Procedures credited for license renewal were identified.
  • Procedures were consistent with the licensing basis and bases documents
  • Procedures contained a reference to conduct an aging management review prior to revising
  • Procedures credited for license renewal were identified by an appropriat~* program indicator and contained a reference to *a* license renewal document Procedure changes were completed as necessary to ensure the above items were satisfied.
12. lh November 2017, as part of oversight reviews of the* Fire Protection Program AMA (UFSAR Section 18.2. 7), an inconsistency was ioentifred in the performance interval for system integrity cfem*onstration by main drain testing. The test interval had been extended from quarterly to each 18 months but the extended interval had not been incorporated into program documents.

An Engineering Assignment to review operating experience to trended performance data to 2011 has been completed with no significant degrading trends observed. The new interval is consistent with the test interval of NFPA 25 (2011 Edition) 'Table 13.1.1.2 modified by NUREG-2191, Section XI.M27; Table XI.M27-1, Note 10.

13. In January 2018 an aging management program-effectiv~ness review was performed for the Fire Protection Program AMA (UFSAR Section 18.2.7). Information from the summary of that effectiveness review is provided below:

The Fire Protection Program AMA is meeting or exceeding the requirements of selected NEI 14-12, "Aging Management Program Effectiveness," elements. Key activities of the Fire Protection Program.AMA that were* reviewed include the inspection.of components, the evaluation of inspection results, repairs/replacements, corrective actions,. and AMA document updates, Engineering reports from 2006* to 2017 of inspections results were reviewed to confirm inspection frequencies were conducted at appropriate intervals and corrective actions taken consistent with 'the observed aging degradation. The review also included p_ertinent issue*s.found in the Corrective Action Program from 2006 through 2017 for age* related degradation of fire protection components within the scope of license renewal. In the past, multiple fire water piping leaks had been identified 'in the Unit 1 and Unit 2 Turbine Buildi'r1gs. As a result, a five phase large scale fire protection piping replacement project has been underway since 2015 to replace Turbine Building header piping and hose station piping as well as. the Unit 1 and' Unit 2 Auxiliary Building Hose station piping. Two of the Turbine Building phases. are complete and two are waiting on testing. Phase five includes the remaining scope. in the turbine building and the entire scope in the Auxiliary 1;3uilding and is planned to start in 2018. Once complete, a large majority of the above ground fire protection PageB-117 Page 63 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal .Appendix B - Aglng Management Programs piping in the plant Will have been replaced, including ~reas where reoccurring leaks were previously identified. The fire water/domestic water storage tanks are managed by the Tank Inspection Activities AMA (UFSAR Section 18.1.3); but, are also discussed here for overall fire protection performance considerations. The fire water/domestic water storage tanks were found to have failing internal coatings and loss of material on the tank floors. Estimates for projected useable tank lifetime and evaluations for additional monitoring were performed. Recommendations are being prepared for repair or replacement project considerations. M[,!ltiple operating issues, and obsolescence of the diesel driven fi,re pump resulted in a design change that replaced the diesel driven fire pump and associated control panel. The new diesel driven fire pump has exhibited substantially improved performance compared to the original fire pump. Activities to implement NFPA 25, 1998 Edition, Section 2-3.1.1 (1998 edition), testing of sprinklers that have been in service for fifty years have been initiated to prove continued functionality. The Unit 1 and Unit 2 turbine building sprinklers have been sampled and will be tested by 2021, when fifty years of service is reached. Recurring Internal Corrosion (RIC) Recurring internal corrosion, inclucfing through-Wall failures due to microbiological induced corrosion, has occurred on several occasions. Periodic fir~ protection system piping flushes, flow testing and piping thickness measurements will be performed to identify pipe degradation prior to loss of system intended function. Periodic visual inspections and tank bottom thickness measurements are performed on the fire water storage tanks. In addition to recent piping replacements in the Turbine B'Liilding and the Auxiliary Building to address instances of RIC due to microbialo!;Jically-influenced corrosion, Low Frequency Electromagnetic Technique (LFET) or a similar technique on 100 *feet of piping during each refueling cycle to detect changes in the* pipe wall thickness. LFET screening or a similar technique will also be performed on accessible interior fire water storage tank bottoms during periodic inspections. Thinned areas found during the LFET scan are followed-up with pipe wall thickness examinations to ensure aging effects are managed and that wal.1 thickness is within acceptable limits. In addition to the pipe wall thickness examination, opportunistic v.isual inspections of the fire protection system will be performed whenever the fire water system is opened for maintenance. The above examples of operating experience provides objective evidence that the Fire Water System program includes activities to perform periodic fire main and hydrant inspections arid flushing, sprinkler inspections. functional test. and flow tests to. identify loss of material, flow blockage, and loss of coating integrity for in-scope water,.based fire protection systems within the PageB-118 Page 64 of 97

Change N_otice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendi.X B - Aging Management Programs, scope of subsequent license renewal_, and to initiate-corrective actions. *Occurrences identified under the* Fire Water System program are evaluated to ensure there is no significant impact to the safe operation of the plant.and corrective actions will be taken to* prevent recurrence. Appropriate guidance or corrective actions for additional Jns*pections. re-evaluation,.repairs, or replacements is provided for locations where agin*g effects are fourid. The program is informed and enhanced when necessary through the systematic arid *ongoing review of both,plant-specific and industry operating experience. There is* reasonable assurance that the continued implementation of the Fire *water system program, following enliancement. will effectively identify aging, and. initiate corrective actions, prior.to a loss of intended function. Conclusion The continued irnplementation of the Fi're Water System program. following enhancement, will provlde r~asonable assurance that aging effects will be managed such that the components within the scope of this program will continue to perform their intended fu.nctions consistent With the current licensing basis during th!;! subsequent period of extended operation. Page 65 of 97

Suny Power Station, Units 1 !ind 2 Application for Subsequent License Renewal Changf;! Notice 1. Appendix B-Aging Management Prog~ms 82.1.19 Reactor Vessel Material* Surveillance Program Description The Reactor Vessel Material Surveillance program is an existin*g condition monitoring program that manages reduction of fracture toughness of the ferritic reactor vessel beltline materials, in accordance with the version of ASTM E-185 available and used during fabrication of the reactor vessels. The program provides sufficient material to monitor reduction of fracture toughness due to neutron.irradiation embrittlement until the end of the subsequent period of extended operation, and determine the need for operating restrictions on the irradiation temperature (i.e., cold leg operating temperature), neutron spectrum, and neutron fluence. The Reactor Vessel Material Surveillance program was developed by Westinghouse Electric Company prior to 10GFR50 Appendix H. The Reactor Vessel Material Surveillance. program consists of two elements. The first element is related to the number of capsules, location of capsules, and content of specimens. The second element is related to the test methods and schedule for testing. For the first element, related to the design of the program, WCAP-7723, "Virginia Electric and Power Co. Surry Unit No. 1 Reactor Vessel Radiation Surveillance Program" and WCAP-80.85, "Virginia Electric and Power Co. Surry Unit No. 2.Reactor Vessel Radiation Surveillance Program for Units 1 and 2. documented* the program. The Reactor Vessel Material Surveillance program for Unit 1 meets either ASTM E 185-66 or ASTM E 185-70. WCAP-8085 states that the Unit 2 Reactor Vessel Material Sutveillance program meets ASTM E-185-70. Initially, the req*uirements relating to the testing method was not mandated by the NRC through a particular version of ASTM E185. Therefore, when a capsule was removed from the reactor Vessel, it was customary at the time to document Which version of ASTM E185 was used for testing. Overtime, the NRC began the process of approving various editions of ASTM E185 for testing. To date. for testing and schedule c;:onsiderations; the NRG has approved three editions of ASTM E185-73, -79, and -82. Currently, the Reactor Vessel Material Surveillance program complies with ASTM E-185-82 for testing and schec;U11ing. Since the withdrawal schedule in Table 1 of ASTM E 185-82 is based on plant operation during the original 40-year initial license term, standby capsules have been incorporated to ensure appropriate monitoring during the subsequent period of extended operation. The Reactor Vessel Material Surveillance program includes removal and testing of at least one capsule, with a n~utron fluence of the capsule between one and two times the projected peak vessel neutron fluence at the end of the subsequent period of extended operation. If a capsule meeting this criteria has not been tested previously, then at least one capsule will be removed and tested during the subsequent period of extended operation (or earlier) to meet this criterion. P~geB-137 Page 66 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs Data from the Reactor Vessel Material Surveillance program is used to monitor neutron irradiation embrittlement of the reactor vessel, and is provided as input to the neutron embrittlement time-limited aging analyses (TLAAs) described in Section 4.2. In accordance with 10 CFR Part 50, Appendix H, all surveillance capsi,lles, including those previously removed from the reactor vessel, must meet the test procedures and reporting requirements of ASTM E 185-82, to the extent practicable, for the configuratiQn of the specim1;1ns in the capsule. Any changes to the capsule withdrawal schedule, including the conversion of standby capsules in the Reactor Vessel Material Surveillance program or extension of the program for the subsequent period of extenc;led operation, are required to be submitted to the Nuclear Regulatory Commission (NRG) for approval prior to implementation, in accordance With 10 CFR Part 50, Appendix H, Paragraph 111.B.3. Standby capsules placed in storage (e.g., removed from the reactor vessel) are maintained for possible future re-insertion. If one or more capsules will not be maintained in such a way as to permit future insertion, then the NRC will be notified of the change. Originally there were eight reactor vessel (RV) capsules installed in each RV prior to plant start-up. Eight capsules is more than the minimum recommended by either ASTM E 185-66 or ASTM E 185-70 for Unit 1 and ASTM E185-70 for Unit 2. Capsule W1 was installed into Unit 2 in 1991 as pa*rt of the Master Integrated ReactorVessel Material Surveillance program. Capsule W1 contained specimens for both Units 1 and 2. Capsule W1 was removed and tested In 1997. The capsules contain representative RV material specimens, neutron dosimeters, arid thermal monitors. Withdrawn capsules from each RV have been tested; one of the remaining untested capsules in each RV will be tested during the initial period of extended operation, one of the remaining untested capsules in each RV will be tested during the subsequent period of extended oper~tion, and the remaining untested capsules (including standby capsul~) in each RV are available to satisfy potential fluence monitoring requirements during the 20-year subsequent period of extended operation. Surveillance Capsule Withdraw Schedule for Unit 1 Four Unit 1 capsules have been withdrawn from the RV (_T, W, V and X). Three capsules have been tested (T, V and X). Only dosimetry was measured for Capsule W. For the initial periqd of extended operati'on, Unit 1 has one untested capsule (Capsule Z), which at its scheduled withdraw~! date will be irradiated o!ose to greater than the projected peak neutron fluence of 6.35 x 1019 n/cm2 (E>1.0 MeV), based upon 68 EFPY at the end of the 80-year subsequent period of extended operation. Capsule Z Is cu'rrently scheduled to be pulled in the 60-year initial period of extended operation during the*~ 2027 Unit 1 refueling outage. As e:urrently scheduled, Capsule Z is estimated to be irradiated to ~ 6.41 x 1019 n/cm2 (E>1.0 MeV}, which would Aot ei<eeed:one times the projeoted peak neutron fiuence at the~enel-efiR& ,so year subsef:iueRt period of 8).~anded oraeratioR.,1.\\.. eapsute-witl:lat=awal-sooea1:1le sha1-1ge 1'1;3s eeeA s1:1bmittea to the NRG to R=tO'Je withelrawal ef Capsule Z ft:lrther out into the initial periea of e)~ Pages..:13a Page 67 of 97

Change Notice 1 Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs aperatleA. Moi.*iA§ witharw..val will eAs1:1re that Caps~le Z 'Nill l=ta*,e eeen 6*peseel te a lluense be between one and two times the projected peak vessel neutron fluence at the end of the 80-year subsequent period of extended operation. The sel:!edule -ohaRge, if apprevee,wm Move the eaf)sule p1::1II to 2027 wheA the ea13s1::1le Ro1:1ti:en fl1:10Aae is pFojeeied to l:le 6.41 x 1019 n!em2 (E>1.0 MeV), whieh is greater than the projected peal< RV ne1:1ti:en flueAee fer 80 years. Testing of Capsule Z in 2027 will satisfy the initial license renewal sch.edule for Unit 1. Untested capsules (including standby capsules) remaining In the Unit 1 RV will be available to satisfy potential fluence monitoring requirements during the 80-year subsequent period of extended operation. Unit 1 will have three untested capsules (Capsules S, U, and Y) irradiated in excess of the 80-year projected peak neutron fluence of 6.35 x 1019 n/cm2 (E>1.0 MeV) during the subsequent period of extended operation. The following irradiation values are estimated at the end of the initial period of extended operation (48 EFPY):

  • Capsule Sis estimated to be irradiated to 5.42 x 1019 n/cm2 (E>1.0 MeV)
  • Capsule U is estimated to be irradiated to 4.59 x 1019 n/cm2 (E>1.0 MeV)
  • Capsule Y is estimated to be irradia\\ed to 6.24 x 1019 n/cm2 (E>1.0 MeV)

An 80-year projected peak neutron fluence irradiation of 6.35 x 1019 n/cm2(E>1.0 MeV) is estimated to be attained by standby Capsules S, U, and Yin 2040, 2047, and 2032, respectively, during the subsequent period of extended operation. Withdrawal and testing of Capsule Y from Unit 1 will satisfy the expectation to test one capsule during the subsequent per:iod of extended operation. Two standby capsules will remain in the reactor, one of which will satisfy the requirement for fluence monitoring specified in ASTM E-185 and required by 10 CFR 50, Appendix H, "Reactor Vessel M~terial Surveillance Program Requirements." Surveillance Capsule Withdraw Schedule for Unit 2 Six of the Unit 2 capsules have been withdrawn from the Unit 2 RV (X, W, W-1, S, V and V). Four capsules have been tested (X, W-1, V and Y). Only dosimetry was measured for Capsule W and Capsule S. For the initial period of extended operation, Unit 2 has one untested capsule (Capsule U) which will be irradiated iR-eMoess of greater than the projected peak neutron fluence of 7.26 x 10.19 n/cm2 (E>1.0 MeV) that is based upon 68 EFPY at the end of the subsequent period of extended operation. Capsule U is scheduled to be pulled in the 60-year initial license renewal period iA 2027 during the 2032 Unit 2 refueling outage. As 81:fffeAtly scheduled, Capsule U is estimated to be irradiated to &Be 7.31 x 1019 n/cm2 (E>1.0 MeV) by 2027, Which would Rel ~1es the projected peak neutron fluence at the eAa ef t!=le 80 year subsequent,acrioa ef maendcd operatioF1. A eapsule i.vithdra'l.'al soheEl1:1le-GRaflge has been sl-:lbmitted to move t[:1e PageB-139 Page 68 of 97

Change Notice 1 Surry Power Station, Units 1 ~nd i Application for Subsequent License Renewal Appendix 8 - Aging Management Programs

  • ~~aFawal ~rtRer 01:1t ime the iRitial pctie~eRded BfileFatioR, ta ens~re'.11:lat iHYi#

ha*.:e-been expeseel ta a fl1:1eRee be between one and two times the projected peak vessel neutron fluence at the end of the 80-year subsequent period of extended operation. :rt::ie ssl:ledule oha~ appre*Jed,-will me*te the saps1:1le p!:111 te 2032 *nheR tl:!c oapsYle projeoted AeYtren ~uenee-lhitll be 7.i1 x 1919 ntcm2.(E>1.0 MeV) whieh is greater thaA ti=le.p~~eutron flueRee for-00 yeaF&: Testing of CapsuleU in 2032 will satisfy the initial lic;ense renewal schedule for Unit 2. Untested capsules (including standby capsules) remaining in the Unit 2 RV will be available to satisfy potential fluence monitoring requirements during the ao~year subsequent period of extended operation. Unit 2 will have two untested capsules Capsules (T and Z) that will be irradiated in excess of the SO-year projected peak neutron fluenoe of 7.26 x 1019.n/cm2 (E>1.0 MeV} during the subsequent period of extended operation. The following irradiation values are estimated at the end of the initial license renewal period ('.48 EFPY): " Capsule Tis estimated to be irradiated to 6.65 x 1 O 19 n/cm2 (E>1.0 MeV)

  • Capsule Z is estimated to be irradiated to 5.39 x 1019 n/cm2 (E>1.0 MeV),

An BO-year projected peak neutron fluence irradiation of 7.26 x 1019 n/cm2(E>1.0 MeV) is estimated to be attained by standby specimen Capsules T and Z in 2036 and 2046, respectively, during the subsequent period of extended operation. Withdrawal and testing of Capsule T from Unit 2 will satisfy the expectation to test one capsule during the subsequent period of extended 13er-iad of operation. One standby capsule will remain in the reactor to satisfy the requirement for fluence monitoring specified in ASTM E-185 arid required by 10 -CFR 50, Appendix H, "Reactor Vessel Material Surveillance Program Requirements. Request for NRC Approval of Changes to the Surveillance Capsule Withdraw Schedule 10 CFR 50, Appendix H; requir:es that prior to withdrawal of Capsule S or U from Unit 1 RV or Capsule Z from Unit 2 RV, a proposed withdrawal schedule with a technic~I justification will l;>e submitted to the NRC for approval. By w~y of this SLR application, Dominion ts requesting that NRC review arid approve the changes to the proposed withdrawal schedule shown in the following:

  • Table B2.1.19-1, Surveillance Capsule Withdraw Schedule For Surry Unit 1, and T~ble 82.1.19-2, Surveillance Capsule Withdraw Schedule For Surry Unit 2.

PageB-140 Page 69 of 97

Change Notice 1 Surry Power Statiqn, Units 1 and 2 Application for Subsequent Ucen~e Renewal Appendix.a. -Aging Management *Programs As part of Operating Experi<:mce, consistent With statements in 'Reg1:11atory Guide 1.99., Revision 2, Dominion considers the use of surveillance data from other sources when they* becom~ available. As *such, information from surveillance capsulei;. withdrawn from sister plant vessels is used to supplement information from the Reactor Vessel Material Surveillance program subject to the credibility limitations stated in Regulatory Position 2.1 and 2.2 of Regulatory Guide 1.99, Revision'2. The Reactor VEJsse.l Material Surveillance program is also used in conjunction with the Neutr<;,n F/uence Monitoring program (832) which monitors neutron fli.Jence for reactor ves$el components and reactor vessel internal components. NUREG-2191 Consistency The Reactor Vessel Material Surveillance program is an existing program that, following enhancement, will be consistent with NUREG-2191, Section XI.M3'1, Reactor Vessel Material Surveillance.. Exception Summary None Enhancements Prior to the subsequent period of extended operation, the following enhancements will be* implemented in the following program eleme_nt(s): Sc.ope of the Program (Element 1), Param~ters Monitored or Inspected (Element 3), Detection of Aging Effects (Element 4), and Monitoring and Trending (Elem~nt 5)

1.

The RV Material Surveillance program for Unit 1 will be amended for Capsule Y to be pulled during the subsequent period of extended operation. Capsule Y will be *pulled during the first refueling outage after the capsule reaches fluence grec:1ter than tod~year vessel irradiation which is between one and two times the projected peak vessel neutron fluence at the end of the subsequent period of extended operation.

2.

The RV Material Surveillance program for Unit 2 will *be amended fot Capsule T to be pulled during the subsequent period of extended operation. Capsule T will bl;! pulled during the first refueling outage after the capsule reaches fluence greater than 1 QO-year vessel irradiation . which is between one and two times the projected peak* vessel nelJtron fluence at the end of the subsequent period of extended operation. PageB-141 Page 70 of 97

Change Notice 1 Operating Experience Summary Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs The following examples of operating experience provide objective evidence that the Reactor Vessel Material Swveillance program has been, and will be effective hi managing the aging effects for SSCs within the scope of the program so that their intended functions will be maintained consistent wi~h the current licensing basis during the subsequent period of extended operation.

1.

Dominion is a member of the Babcock and Wilcox Owner's Group Reactor Vessel Working Group (RVWG).. While not required, SPS participates in the RVWG's Master Integrated Reactor Vessel Surveillance Program (MIRVSP). The MIRVSP integrates the plant specific reactor vessel surveillance* programs of the participants, the existing supplemental B&W Owners Group irradiation capsules, and additional supplemental irradiation capsules to assure the availability of high fluence and thermal annealing data for the participants' reactor vessels. One objective of the MIRVSP is to maximize the effectiveness of data sharing among participants to assure that required data is available to the participants for current and. extended plant operation.

2.

In 1997, Unit 1 Capsule X Withdrawal and Test: Per BAW-2324, "Analysis of Capsule X, Virginia Power Surry Unit No. 1," the specimens in Unit 1 Capsule X were exposed to fluences equivalenMo approximately 16:1 EFPY, 2.11 x 10-19 n/cm2 based on the calculated fluence, and satisfy the upper-shelf energy criterion and the pressurized thermal shock reference temperature screening criteria. The adJusted reference temperatures have been shown to be less than those used in the Unit 1 P-T limit curves, thereby demonstrating margin in the operating limits.

3.

In 2002, Unit 2 Capsule Y Withdrawal and Test: Per WCAP-16001, "Analysis of Capsule Y from Dominion Surry Unit 2 R.eactor Vessel Radiation Surveillance Program, the specimehs in Unit 2 Capsule Y were expos(;}d. to fluences.equivalent to approximately 20.3 EFPY, 2. 72 x 1019.n/cm2 b~sed on the calculated fluence, and satisfy the Upper-shelf energy criterion and the pressurized thermal shock reference temperature screening criteria. The adjusted reference temperatures have been shown to be less than those used in the Unit 2 P-T limit curves. thereby demonstrating margin in the operating limits.

4.

In December 2016, as part of oversight review activities, a review of procedures credited by initial license renewal AMAs was conducted to confirm the following:

  • Procedures credited for license renewal were identified 0 Procedures were consistelitwith the licensing basis and bases documents.
  • Procedures contained a referenc;:e to conduct an aging management review prior tQ revfsing
  • p*rocedures credited for license renewal were identified by an appropriate program indicator and contained a reference to a license renew13I document PageB-142 Page 71 of 97

Change Notice 1 Surry Power Station, Uriits 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs Procedure changes were completed as necessary. to ensure the above items were satisfied.

5.

In November 2017, as part of oversight review activities, the Reactor Vessel Integrity Management Activity (UFSAR Section 18.2.14) AMA owner confirmed that AMA inspections had been performed and the inspections addressed the required SSCs consistent with the aging management activity commitments. No gaps were identified by the review.

6.

In January 2018, an aging management program effectiveness review was performed of the Reactor Vessel Integrity Management Activity (UFSAR Section 18.2.14}. Information from the summary of that effectiveness review is provided below: The Reactor Vessel Integrity Management Activity is meeting or exceeding the requirements of selected NEI 14-12, "Aging Management Program Effectiveness," elements. Key activities of .the Reactor Vessel Integrity Management Activity that were reviewed included aging management ~ctivity procedures, documents, and incorporation of industry operating experience. The AMA procedure and associated documents were examined to evaluate the effectiveness of the Reactor Vessel Integrity Management Activity with respect to aging management. The procedure defines activities required to ensure adequate fracture toughness of the reactor vessel beltline plate and weld material consistent with the following parameters: heatup and cooldown limits, PTS reference temperature, a bounding fast fluence value, and upper shelf energy. These parameters are documented in the SPS UFSAR and Technical Specifications and as such changes to these parameters require NRC review. As a result of tke re11ised 13rojeetea flueAoe salculatiens performed for the RV Aozzles a ro*.*isioA ts tRe Feaster vessel 1llateria-l-s1:1FYeillanse sapsul0-JA1itf1Elraw scheElule-w~ t~ tt:le f:'!RG for approval by DomiRian-Ener-gy ViF§iAia-~F- ~+ 243 (July 2Q17) to refleot the l1?tes_t projeote~ fh,JeRee oaleulatiens in the e_sti1:AateEI ea13l*fle.fluenee >Jalue,s. Th~esea Gllanges pFOYiae asset optimization ane-ens1:1ro tl=ie roviseel estimated sklneey earasl:ile fluenoo -values ooineiee with-#te-nearest FOSfimetiV-O unit rofl:leliA§ sutage foR.\\*iU:idrawal. A review of industry operating experience resulted in a program procedure revision to include Westinghouse Technical Bulletin TB-16-5 that ensures proper installation and seating of surveillance capsules. The Reactor Vessel Integrity Management Activity ensures that the Dominion reactor vessels are consistent with the applicable regulations and industry standards with respect to reactor vessel embrittlement concerns. PageB-143 Page 72 of 97

Change Notice t Surry Pqwer Station, Units 1 and 2. Application for Subsequent License Renewal Appendix B - Aging Management Programs The above examples of operating experience provides objective evidence that the ~eactor V~ssel Material Swveillance program includes activities to perform withdrawal and testing of reactor vessel capsule spectmens to manage a *reduction in fracture toughness due to irradiation of the ferritic reactor vessel beitline materials, and to initiate* corrective actions. Occurrences identified under the Reactor Vessel Material Surveillance program are evaluated to ensure there is no significant impact to the safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance or corrective actions for additional inspections, re-evaluation, repairs, or replacements. are provided for locations where aging effects are found. The program is informed and enhanced when necessary through the systematic and ongoing review of bpth plant-specific and industry operating experrence. There is reasonable assurance that the continued implementation of the* Reactor V~ssel Material Surveillance program, following enhancement. will effectively manage aging prior to a loss of intended function. Conclusion

1.

The continued implementation of the Reactor Vessel Material Surveillance program, following enhancement, will provide reasonable ~ssurance that aging effects will be managed such that the components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis during_the subsequent period of extended operation. PageB~144 Page 73 of 97

Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Change Notice 1 Appendix B - Aging Management Programs 82.1.23 External Surfaces Monitoring of Mechanical Components Program Description The External Surfaces Monitoring of Mechanical Components program is an existing condition monitoring program that manages loss of material, cracking, and reduction of heat transfer of metallic components; hardening or loss of strength, loss of material, and cracking or blistering of polymeric components; loss of preload of HVAC closure bolting; and reduced thermal insulation resistance. Visual inspections are performed during system inspections and walkdowns. The inspection parameters for metallic components include material condition, which consists of evidence of rust, general, pitting, and crevice corrosion; surface imperfections such as cracking and wastage; coating degradation such as cracking, flaking, *or blistering; evidence of insulation damage or wetting; leakage; and accumulation of debris on heat exchanger surfaces. Coating degradation is used as an indicator of possible degradation on underlying surfaces of the component. Inspection parameters for elastomeric and polymeric components include blistering, hardening, discoloration, surface cracking, crazing, scuffing, loss of thickness, exposure of internal reinforcement, and dimensional changes. For certain materials, such as flexible polymers, physical manipulation to detect hardening or loss of strength will be used to augment the visual inspections conducted under this program. Periodic visual inspections, not to exceed a refueling outage interval, of metallic and polymeric components and insulation jacketing (insulation when not jacketed) are conducted. This frequency accommodates inspections of components that may be in locations that are normally only accessible during refueling outages. Surfaces that are not readily visible during plant operations and refueling outages are inspected when they are made accessible and at such intervals that would ensure the components intended functions are maintained. There are no cementitious components within the scope of this program. ASME Code, Section XI visual examinations (VT-1) or surface examinations will be conducted to detect cracking of stainless steel.. afK:t-aluminum and copper alloy (>15% Zn or >8% Al) components exposed to aqueous solutions or air environments containing halides. A minimum sample of 25 inspections will be performed from each of the aluminum and stainless steel component populations every ten years. A sample of outdoor component surfaces that are insulated and a sample of indoor insulated components exposed to condensation (due to the in-scope component being operated below the dew point), will be periodically inspected every ten years during the subsequent period of extended operation. Following insulation removal, ASME Code, Section XI VT-1 examinations or surface examinations will be conducted to detect loss of material and cracking of the component surfaces. PageB-158 Page 74 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs A minimum of twenty-five one foot axial length piping sections and components for each material type will be inspected. If any sampling-based inspections to detect cracking in stainless steel... aREi-aluminum and copper alloy (>15% Zn or >8% Al) do not meet the acceptance criteria, additional inspections will be conducted, unless the cause of the aging effect for each applicable material and environment is corrected by repair or replacement. There will be no fewer than five additional inspections for each inspection that did not meet acceptance criteria, or 20% of each applicable material, environment, and aging effect combination inspected, whichever is less. If any subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis will be conducted to determine the further extent of inspections required. Additional samples will be inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. The additional inspections will include inspections of components with the same material, environment, and aging effect combination at both Unit 1 and Unit 2. The additional inspections will be completed within the interval (i.e., 10 year inspection interval) in which the original inspection was conducted. Where practical, the inspections will focus on the bounding or lead components most susceptible to aging because of time in-service, severity of operating conditions, and lowest design margin. Inspections are performed by personnel qualified in accordance with site procedures and programs to perform the specified task. Inspections within the scope of the ASME Code will follow site procedures consistent with the ASME Code. Non-ASME Code inspection procedures will include requirements for items such as lighting, distance, offset, surface coverage, and presence of protective coatings. Acceptance criteria are such that the component will meet its intended function until the next inspection or the end of the subsequent period of extended operation. For quantitative analyses, the required minimum wall thickness to meet applicable design standards will be used. For qualitative evaluations, applicable parameters such as ductility, color, and other indicators will be addressed to ensure a decision is based on observed conditions. The external surfaces of components that are buried or in underground environments are inspected by the Buried and Underground Piping and Tanks program (82.1.27). The external surfaces of outdoor tanks and indoor large volume metallic storage tanks (capacity >100,000 gallons) are inspected by the Outdoor and Large Atmospheric Metallic Storage Tanks program (82.1.17). Loss of material due to boric acid corrosion is managed by the Boric Acid Corrosion program (82.1.4). PageB-159 Page 75 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs NUREG-2191 Consistency The External Surfaces Monitoring of Mechanical Components program is an existing program that, following enhancement, will be consistent with NUREG-2191, Section XI.M36, External Surfaces Monitoring of Mechanical Components. Exception Summary None Enhancements Prior to the subsequent period of extended operation, the following enhancement(s) will be implemented in the following program element(s): Preventive Actions (Element 2)

1.

The Engineering walkdown procedure will be revised to include an item in the walkdown checklist to inspect insulation metallic jacketing for any damage that would permit in-leakage of moisture. Parameters Monitored/Inspected (Element 3) and Detection of Aging Effects (Element 4)

2.

The Engineering walkdown procedure will be revised to add the following requirements:

a. Metallic Components
  • No surface imperfections, loss of wall thickness, flaking, or oxide coated surfaces
  • No blistering of protective coating
  • No evidence of leakage (for detection of cracks) on the surfaces of stainless steel... aAa aluminum and copper alloy (>15% Zn or >8% Al) components
  • No accumulation of debris on air-side heat exchanger surfaces
b. Elastomers and Flexible Polymers
  • No exposure of reinforcing fibers, mesh or underlying metal (for elastomers or flexible polymers with internal reinforcement)
  • No blistering, loss of thickness, dimensional change, or scuffing
  • No hardening of elastomeric elements as evidenced by a loss of suppleness during tactile inspection
c. Insulation Metallic Jacketing
  • Inspect insulation metallic jacketing for any damage that would permit in-leakage of moisture.

PageB-160 Page 76 of 97

Change Notice 1

d. HVAC Closure Bolting Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs
  • Check that a sample of closure bolting that is in reach is not loose Detection of Aging Effects (Element 4)
3.

The Engineering walkdown procedure will be revised to specify that walkdowns will be performed at a frequency not to exceed one refueling cycle. Since some surfaces are not readily visible during both plant operations and refueling outages, the enhancement will also specify that such surfaces will be inspected when they are made accessible and at such intervals that would ensure the components' intended functions are maintained. Detection of Aging Effects (Element 4)

4.

The Engineering walkdown procedure will be revised to provide non-ASME Code inspection guidance related to lighting, distance and offset for walkdown inspections. The procedure will specify adequate lighting be verified at the inspection location to detect degradation. Lighting may be permanently installed, temporary, or portable (e.g., flashlight), as appropriate. For accessible surface inspections, inspecting from a distance of two to four feet (or less) will be appropriate. For distant surface inspections, viewing aids such as binoculars may be used. For viewing angles which may prevent adequate inspection, a viewing aid such as an inspection mirror or boroscope should be used.

5.

A new procedure will be developed to specify that in each 10-year period during the subsequent period of extended operation, the minimum number of inspections is completed. A minimum of 25 inspections for cracking will be performed from each of the stainless steel.,_ aRa aluminum and copper alloy (>15% Zn or >8% Al} component populations assigned to the program every ten years. For insulated components exposed to condensation, a minimum of 25 one foot axial length sections and components for each material and environment combination will be inspected for loss of material and cracking after the insulation is removed. The new procedure will specify that the inspections focus on the components most susceptible to aging because of time in service, severity of operating conditions, and lowest design margin.

6.

The Engineering walkdown procedure will be revised to specify that visual inspection of elastomers and flexible polymers will be supplemented by tactile inspection to detect hardening. Visual inspections will cover 100% of accessible component surfaces. The minimum surface area for tactile inspections will be at least 10% of the accessible surface area. PageB-161 Page 77 of 97

Change Notice 1 Monitoring and Trending (Element 5) Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

7.

A new procedure will be developed to evaluate and project the rate of any degradation until the end of the subsequent period of extended operation or the next scheduled inspection, whichever is shorter. The inspection sampling bases (e.g., selection, size, frequency) will be adjusted as necessary based on the projection. Acceptance Criteria (Element 6)

8.

A new procedure will be developed to specify that, where practical, acceptance criteria are quantitative (e.g., minimum wall thickness). For quantitative analyses, the required minimum wall thickness to meet applicable design standards will be used. For qualitative evaluations, applicable parameters such as ductility, color, and other indicators will be addressed to ensure a decision is based on observed conditions. Corrective Actions (Element 7)

9.

A new procedure will be developed to specify that additional inspections will be performed if any sampling-based inspections to detect cracking in stainless steel... ~aluminum and copper alloy (>15% Zn or >8% Al) components do not meet the acceptance criteria, unless the cause of the aging effect for each applicable material and environment is corrected by repair or replacement. There will be no fewer than five additional inspections for each inspection that did not meet acceptance criteria, or 20% of each applicable material, environment, and aging effect combination inspected, whichever is less. If any subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis will be conducted to determine the further extent of inspections required. Additional samples will be inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. The additional inspections will include inspections of components with the same material, environment, and aging effect combination at both Unit 1 and Unit 2. The additional inspections will be completed within the interval (e.g., 10-year inspection interval) in which the. original inspection was conducted. PageB-162 Page 78 of 97

Change Notice 1 Operating Experience Summary Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs The following examples of operating experience provide objective evidence that the External Surfaces Monitoring of Mechanical Components program has been, and will be effective in managing the aging effects for SSCs within the scope of the program so that their intended functions will be maintained consistent with the current licensing basis during the subsequent period of extended operation.

1.

In November 2009, Engineering noted a section of a condenser waterbox outlet rubber expansion joint was blistered and was soft to the touch. Photos were taken of the condition, and a condition report written. Engineering evaluated the condition against the criteria in a station inspection procedure. The evaluator noted that there was no liquid behind the soft areas, no cracking, and no delamination. The evaluator noted that the procedure indicated that soft spongy area on the internal circumference of a joint could be due to uncured arch material. Therefore, using the guidance in the procedure, the condition was determined to be

  • acceptable.
2.

In May 2013, during a system walkdown outdoors, vegetation was noted growing in the insulation of three lines associated with the fire protection system. The insulation was removed, and no damage to the piping from the vegetation was noted, however, some rusting was noted on the surface of the piping. The damaged insulation was repaired to prevent any further water intrusion.

3.

In September 2013, corrosion was noted on the bottom of a section of Unit 1 emergency service water pump discharge piping. The external pipe coating was bulging, indicating corrosion beneath. Additionally, a piece of the coating was missing. Engineering performed non-destructive examination (NOE) on the area of localized coating degradation. The pipe wall thickness results were compared against the minimum wall thickness and found to be acceptable. Based on engineering evaluation, no further degradation was expected following recoating of the pipe.

4.

In March 2014, an inspection of ductwork upstream of a cable spreading room air handler was performed. The inspection identified an area of corrosion in the top of a duct elbow and a condition report was submitted. A follow-on inspection with the insulation removed documented substantial rust damage on multiple sections of the ducting and another condition report was written. The unit was subsequently replaced as part of a design change to rectify persistent ventilation degradation and equipment obsolescence issues. The design change replaced the major mechanical components of the Unit 1 and Unit 2 cable spreading room ventilation systems and repaired associated ductwork. The design change also included replacement of the insulation and covering of the ductwork with an aluminum jacket for enhanced protection from water intrusion. Aluminum jacket is installed in a manner so as to shed water consistent with plant specifications. PageB-163 Page 79 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

5.

In December 2015, an effectiveness review of the General Condition Monitoring Activities (UFSAR Section 18.2.9) was performed. This aging management activity (AMA) was evaluated against the performance criteria identified in NEI 14-12 for the Detection of Aging Effects, Corrective Actions, and Operating Experience program elements. System engineer walkdowns were identified as not being consistently maintained in the designated plant database and the walkdown attributes associated with license renewal activities were not being documented. The issues were documented in the Corrective Action Program. Corrective actions included:

  • Development and implementation of work group specific training for engineering roles and responsibilities related to walkdowns.
  • Implementation of changes to the walkdown procedure
  • Implementation of a process for ensuring system walkdown records are maintained
  • Development of a template in the walkdown tracking database to match the specific requirements in the walkdown procedure A follow-up review was performed in February 2016, when 22 of the 24 corrective actions had been completed. The review indicated that walkdowns were being performed and documented in accordance with license renewal requirements. The remaining corrective actions were completed subsequent to the follow-up review.
6.

In December 2016, as part of oversight review activities, a review of procedures credited by initial license renewal AMAs was conducted to confirm the following:

  • Procedures credited for license renewal were identified
  • Procedures were consistent with the licensing basis and bases documents
  • Procedures contained a reference to conduct an aging management review prior to revising
  • Procedures credited for license renewal were identified by an appropriate program indicator and contained a reference to a license renewal document Procedure changes were completed as necessary to ensure the above items were satisfied.
7.

In November 2017, as part of oversight review activities, the General Condition Monitoring Activities (UFSAR Section 18.2.9) AMA owner confirmed that AMA inspections had been performed and the inspections addressed the required SSCs consistent with the aging management activity commitments. No gaps were identified by the review. PageB-164 Page 80 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

8.

In January 2018, an aging management program effectiveness review was performed of the General Condition Monitoring Activities (UFSAR Section 18.2.9). Information from the summary of that effectiveness review is provided below: The General Condition Monitoring Activities are meeting or exceeding the requirements of selected NEI 14-12, "Aging Management Program Effectiveness," elements. Key activities of the General Condition Monitoring Activities that were reviewed include system engineer walkdowns to identify age-related degradation of plant equipment within the scope of license renewal. Walkdown records from 2006 through 2017 were reviewed to confirm inspection frequencies were conducted at appropriate intervals and corrective actions were taken consistent with the observed aging degradation. The review also included pertinent issues found in the Corrective Action Program from 2006 through 2017 identified during walkdowns. In 2015, several issues with Engineering walkdowns were identified, including that the walkdowns were not being documented and maintained in the tracking database as required. This operating experience is discussed in item number five above. The above examples of operating experience provide objective evidence that the External Surfaces Monitoring of Mechanical Components program includes activities to perform visual inspections to manage loss of material, cracking, and reduction of heat transfer of metallic components; hardening or loss of strength, loss of material, and cracking or blistering of polymeric components; loss of preload of HVAC closure bolting; and reduced thermal insulation resistance of components within the scope of subsequent license renewal, and to initiate corrective actions. Occurrences identified under the External Surfaces Monitoring of Mechanical Components program are evaluated to ensure there is no significant impact to the safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance or corrective actions for additional inspections, re-evaluation, repairs, or replacements is provided for locations where aging effects are found. The program is informed and enhanced when necessary through the systematic and ongoing review of both plant-specific and industry operating experience. There is reasonable assurance that the continued implementation of the External Surfaces Monitoring of Mechanical Components program, following enhancement, will effectively manage aging prior to a loss of intended function. Conclusion The continued implementation of the External Surfaces Monitoring of Mechanical Components program, following enhancement, will provide reasonable assurance that aging effects will be managed such that the components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis during the subsequent period of extended operation. PageB-165 Page 81 of 97

Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Change Notice 1 Appendix B - Aging Management Programs 82.1.25 Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components Program Description The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program is an existing condition monitoring program that manages loss of material, cracking, reduction of heat transfer, and flow blockage of metallic components. The program also manages hardening or loss of strength, loss of material, cracking or blistering, and flow blockage of polymeric components. This program consists of visual inspections of accessible internal surfaces of piping, piping components, ducting, heat exchanger components, polymeric and elastomeric components,' and other components exposed to air, condensation, diesel exhaust, fuel oil, lubricating oil, and any water environment. Aging effects associated with items (except for elastomers) within the scope of the Open-Cycle Cooling Water System program (B2.1.11 ), Closed Treated Water Systems program (B2.1.12), and Fire Water System program (B2.1.16) are not managed by this program. Inspections of metallic components monitor for visible evidence of loss of material. Indicators of aging effects for metallic components include corrosion and surface imperfections; loss of wall thickness; flaking or oxide-coated surfaces; debris accumulation on heat exchanger tube surfaces; and accumulation of particulate fouling, biofouling, or macro fouling. ASME Code, Section XI visual (VT-1) examinations or surface examinations will be conducted to detect cracking of stainless steel.. aREl-aluminum and copper alloy (>15% Zn) components. Inspections of polymeric and elastomeric components monitor for changes in material properties or loss of material. Indicators of loss of material and changes in material properties include surface cracking, crazing, scuffing, loss of sealing, dimensional change, loss of wall thickness, discoloration, exposure of internal reinforcement, hardening, and blistering. Physical manipulation or pressurization will be used to augment the visual examinations conducted under this program in order to detect hardening or loss of strength. The internal inspections are performed during the periodic system and component surveillances or during the performance of maintenance activities when the surfaces are made accessible for visual inspection. At a minimum, in each 10-year period during the subsequent period of extended operation, a representative sample of 20% of the population (defined as components having the same combination of material, environment, and aging effect) or a maximum of nineteen components per population at each unit will be inspected. Where the sample size is not based on the percentage of the population, it is acceptable to reduce the total number of inspections to nineteen components per population at each unit. The reduced total number of inspections is acceptable because the operating conditions and history at each unit are sufficiently similar (e.g., flowrate, chemistry, temperature, excursions) such that aging effects are not occurring differently between the units. Past power up-rates were implemented for both PageB-169 Page 82 of 97

Change Notice 1 Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs units at approximately the same time. Historically, water chemistry conditions between the two units have been very similar. The raw water source for both units is the James River. Emergency diesel generator runs are managed to equalize total run times among the diesels, so as to equalize wear and aging. Operating experience for each unit demonstrates no significant difference in aging effects of systems in the scope of this program between the two units.. If any inspections do not meet the acceptance criteria, additional inspections will be conducted, unless the cause of the aging effect for each applicable material and environment is corrected by repair or replacement. There will be no fewer than five additional inspections for each inspection that did not meet acceptance criteria, or 20% of each applicable material, environment, and aging effect combination inspected, whichever is less. If any subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis will be conducted to determine the further extent of inspections required. Additional samples will be inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. The additional inspections will include inspections of components with the same material, environment, and aging effect combination at both Unit 1 and Unit 2. The additional inspections will be completed within the interval (i.e., refueling outage interval, 10-year inspection interval) in which the original inspection was conducted or, if identified in the latter half of the current inspection interval, within the next refueling outage interval. Where practical, the inspections will focus on the bounding or lead components most susceptible to aging because of time in-service, and severity of operating conditions. Opportunistic inspections will continue in each period even if the minimum number of inspections has been conducted. Inspections are performed by personnel qualified in accordance with procedures and programs to perform the specified task. Inspections within the scope of the ASME Code will follow procedures consistent with the ASME Code. Non-ASME Code inspection procedures will include requirements for items such as lighting, distance, offset, surface coverage, presence of protective coatings, and cleaning processes. Acceptance criteria are such that the component will meet its intended function until the next inspection or the end of the subsequent period of extended operation. For quantitative analyses, the required minimum wall thickness to meet applicable design standards will be used. For qualitative evaluations, applicable parameters such as ductility, color, and other indicators will be addressed to ensure a decision is based on observed conditions. NUREG-2191 Consistency The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program is an existing program that, following enhancement, will be consistent with NUREG-2191, Section XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components. PageB-170 Page 83 of 97

Change Notice 1 Exception Summary None Enhancements Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs Prior to the subsequent period of extended operation, the following enhancement(s) will be implemented in the following program element(s): Parameters Monitored/Inspected (Element 3) and Detection of Aging Effects (Element 4)

1.

Procedures will be revised to require inspection of metallic components for flaking or oxide-coated surfaces.

2.

Procedures will be revised to require inspection of elastomeric and flexible polymeric components for the following:

a. Surface crazing, scuffing, loss of sealing, blistering, and dimensional change (e.g.,

"ballooning" and "necking")

b. Loss of wall thickness
c. Exposure of internal reinforcement (e.g., reinforcing fibers, mesh, or underlying metal) for reinforced elastomers
3.

Procedures will be revised to specify that visual inspection of elastomeric and flexible polymeric components is supplemented by tactile inspection to detect hardening or loss of suppleness. The minimum surface area for tactile inspections will be at least 10% of the accessible surface area. Detection of Aging Effects (Element 4)

4.

Procedures will be revised to provide non-ASME Code inspection guidance related to lighting, distance, offset, surface coverage, presence of protective coatings, and cleaning processes. The procedure will specify adequate lighting be verified at the inspection location to detect degradation. Lighting may be permanently installed, temporary, or portable (e.g., flashlight), as appropriate. For accessible surface inspections, inspecting from a distance of two feet or less will be appropriate. For viewing angles which may prevent adequate inspection, a viewing aid such as an inspection mirror or boroscope should be used. For internal inspections, accessible surfaces will be inspected. If inspecting piping internal surfaces, a minimum of one linear foot will be inspected, if accessible. Cleaning will be performed, as necessary, to allow for a meaningful examination. If protective coatings are present, the procedure will require the condition of the coating to be documented. PageB-171 Page 84 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

5.

A new procedure will be developed to specify that in each 10-year period during the subsequent period of extended operation, the minimum number of inspections is completed for the various sample populations (each material, environment, and aging effect combination). If opportunistic inspections will not fulfill the minimum number of inspections by the end of each 10-year period, the program owner will initiate work orders as necessary to request additional inspections. A representative sample of 20% of the population (defined as components having the same material, environment, and aging effect combination) or a maximum of nineteen components per population at each unit will be inspected. The new procedure will specify that the inspections focus on the bounding or lead components most susceptible to aging due to time in service and severity of operating conditions. Monitoring and Trending (Element 5) and Acceptance Criteria (Element 6)

6.

A new procedure will be developed to evaluate and project the rate of any degradation until the end of the subsequent period of extended operation or the next scheduled inspection, whichever is shorter. The inspection sampling bases (e.g., selection, size, frequency) will be adjusted as necessary based on the projection. Acceptance Criteria (Element 6)

7.

A new procedure will be developed to specify that, where practical, acceptance criteria are quantitative (e.g., minimum wall thickness). For quantitative analyses, the required minimum wall thickness to meet applicable design standards will be used. For qualitative evaluations, applicable parameters such as ductility; color, and other indicators will be addressed to ensure a decision is based on observed conditions. Corrective Actions (Element 7)

8.

A new procedure will be developed to specify that additional inspections will be performed if any sampling-based inspections do not meet the acceptance criteria, unless the cause of the aging effect for each applicable material and environment is corrected by repair or replacement. There will be no fewer than five additional inspections for each inspection that did not meet acceptance criteria, or 20% of each applicable material, environment, and aging effect combination are inspected, whichever is less. If any subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis will be conducted to determine the further extent of inspections required. Additional samples will be inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. The additional inspections will include inspections of components with the same material, environment, and aging effect combination at both Unit 1 and Unit 2. The additional inspections will be completed within the interval (e.g., refueling outage interval, 10-year inspection interval) in which the original inspection was conducted or, if identified in the latter half of the current inspection interval, within the next refueling outage interval. PageB-172 Page 85 of 97

Change Notice 1 Operating Experience Summary Surry Power station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs The following examples of operating experience provide objective evidence that the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program has been, and will be effective in managing the aging effects for SSCs within the scope of the program so that their intended functions will be maintained consistent with the current licensing basis during the subsequent period of extended operation.

1.

In January 2009, a leak was identified in a raw water vacuum priming elbow servicing a Unit 1 component cooling heat exchanger. The condition was determined to be pitting due to microbiologically induced corrosion (MIC). The pipe section was removed and replaced. A separate condition report written at the same time documented another leak at a different location in the same section of piping. Three separate through wall leaks were noted on this section of piping and documented on the two condition reports. To provide more information as to extent of condition, another section of vacuum priming pipe on a different component cooling heat exchanger was removed, and showed evidence of MIC, although not through wall. Engineering recommended creation of preventive maintenance items to replace the vacuum priming piping with similar configuration to the MIC-damaged sections on the four Unit 1 component cooling heat exchangers every ten years to prevent future through wall leaks. The new preventive maintenance items were approved in October 2010.

2.

In March 2012, during performance of a preventive maintenance activity, it was identified that the housing for an air handling unit was degraded. The internal condition of the housing showed corrosion of the metal. The unit was subsequently replaced as part of a design change to rectify persistent ventilation degradation and equipment obsolescence issues. The design change replaced the major mechanical components of the Unit 1 and Unit 2 cable spreading room ventilation systems and repaired associated ductwork.

3.

In May 2013, Engineering performed non-destructive examination on a length of Unit 2 recirculation spray heat exchanger service water vent piping. An elbow in the length of piping showed significant wall thinning. This piping is vented to atmosphere, but is temporarily fully wetted with service water when flow testing the recirculation spray heat exchangers. Quarterly ultrasonic testing of the piping was performed to monitor the progression of thinning until the piping was replaced in the next outage. Inspection during the replacement of the piping documented exfoliation due to corrosion. This is an example of recurring internal corrosion in the service water system. PageB-173 Page 86 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

4.

In May 2015, discharge piping in the Unit 1 Turbine Building from plumbing system sump pumps was identified to have several leaks at a threaded fitting at a rate of four to five gallons per minute. The fitting material is cast iron exposed to waste water. The sump liquid pH was determined to be neutral, so the cause was attributed to corrosion from stagnant water over time. Other recent examples of leaks in plumbing system piping at fittings have also been noted. Soft patch repairs were made to the leaks, and work orders initiated to replace the piping. This is an example of recurring internal corrosion in the plumbing system.

5.

In December 2015, an effectiveness review was performed of the Work Control Process Activity (UFSAR Section 18.2.19). The aging management activity (AMA) was evaluated against the performance criteria identified in NEI 14-12 for the Detection of Aging Effects, Corrective Actions, and Operating Experience activity elements. A sample of completed as-found inspection forms was reviewed and identified that the documentation of as-found inspections was inconsistent and needed improvement. As a corrective action, training of mechanical maintenance personnel on expectations for properly documenting as-found conditions was conducted. An additional corrective action that recommended enhancer:nent of the as-found inspection form was closed administratively. This operating experience is revisited in the January 2018 AMP effectiveness review. Due to the need for additional improvements noted during the January 2018 AMP effectiveness review, a condition report was entered into the Corrective Action Program.

6.

In December 2016, as part of oversight review activities, a review of procedures credited by initial license renewal AMAs was conducted to confirm the following:

  • Procedures credited for license renewal were identified
  • Procedures were consistent with the licensing basis and bases documents
  • Procedures contained a reference to conduct an aging management review prior to revising
  • Procedures credited for license renewal were identified by an appropriate program indicator and contained a reference to a license renewal document Procedure changes were completed as necessary to ensure the above items were satisfied.
7.

In November 2017, as part of oversight review activities, the Work Control Process Activity (UFSAR Section 18.2.19) AMA owner confirmed that AMA inspections had been performed and the inspections addressed the required SSCs consistent with the aging management activity commitments. No gaps were identified by the review. PageB-174 Page 87 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs

8.

In January 2018, an aging management program effectiveness review was performed of the Work Control Process Activity (UFSAR Section 18.2.19). Information from the summary of that effectiveness review is provided below: The Work Control Process Activity plans and conducts testing and maintenance activities, both preventive and corrective. Visual inspections are conducted of the internal surfaces of plant components and adjacent piping that are in the scope of license renewal to monitor for aging effects such as cracking and loss of material. Potential age-related degradation conditions are recorded on "as-found" inspection forms and dispositioned as necessary in the Corrective Action Program. A review was performed of station operating experience identified via the Work Control Process Activity, including conditions identified in the Corrective Action Program from 2006 through 2017. While the automatic inclusion of the as-found inspection form in work packages ensures that inspections are performed on in-scope components, a review of a sampling of completed inspection forms throughout the period from 2006 to 2017 showed that inspection personnel are not consistent in the level of detail provided on the form when recording observed conditions. A self-assessment of the License Renewal program documented the issue of inconsistent level of detail on as-found inspection forms in 2015. This operating experience is discussed in item number five above. Corrective actions completed as a result of this Condition Report do not appear to have been effective. A sample of as-found inspection forms from March to June 2017 (after the corrective actions were completed) was reviewed and contained the following typical discrepancies:

  • Condition Report numbers not appropriately documented on the inspection sheets concerning discovered aging effects
  • Aging effects not described in detail and documented in the inspection sheet notes section
  • Aging effects table not filled out adequately
  • License Renewal inspection sheets inappropriately dispositioned To improve program effectiveness, the following will be addressed and documented during the next aging management program effectiveness review:
  • Investigation and evaluation of inspection results and corrective actions from a sample population of License Renewal equipment work orders
  • Clarification of procedural guidance on inspection parameters including documentation of aging effects
  • Re-training of inspection personnel (current staffing and maintenance of this population of inspectors)
  • Re-training of personnel reviewing inspection forms (current staffing and maintenance of this population of reviewers)

PageB-175 Page 88 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs A condition report has been generated in the Corrective Action Program to document and track implementation of these corrective action Recurring Internal Corrosion (RIC) Recurring internal corrosion, including through-wall failures due to pitting and general corrosion, has been observed in the service water and plumbing systems. Occurrences in the service water system have been noted over a period from 2007 to 2013. Occurrences in the plumbing system have been noted over a period from 2011 to 2018. Corrective actions have been taken previously, and additional actions have been initiated as noted below to minimize the likelihood of piping and component degradation due to pitting and general corrosion in systems monitored by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (82.1.25). Future occurrences of RIC will be documented in accordance with the Corrective Action Program. Corrective actions include:

  • Sections of service water piping not within the scope of GL 89-13, "Service Water System Problems Affecting Safety-Related Equipment," that have documented leaks in the past due to corrosion of carbon steel from a raw water environment have been replaced.

Opportunistic inspections of susceptible piping and components will be performed when the system boundary is opened. Periodic system walkdowns in accordance with plant procedure will monitor for leakage. Addition*a1 corrective actions will be determined via the Corrective Action Program if significant loss of material is detected.

  • Work orders have been created to replace affected portions of the plumbing system piping along an approximately 77 foot length in the Unit 1 Turbine Building basement that have documented leaks from corrosion due to stagnant water in the lines. Opportunistic inspections of susceptible piping and components in other portions of the system within the scope of subsequent license renewal will continue to be performed when the system boundary is opened.

Recurring internal corrosion has also been observed in various lined or coated components, such as the main condenser channel heads and the 96 inch circulating water discharge piping. The aging effects of internally coated/lined surfaces are managed by the Internal Coatings/Linings For In-Scope Piping, Piping Components, Heat Exchangers, and Tanks program (82.1.28). Specific operating experience examples and corrective actions that discuss such aging effects are documented in the Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks program. The above examples of operating experience provide objective evidence that the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program includes activities to perform opportunistic inspections to identify loss of material, cracking, reduction of heat transfer, PageB-176 Page 89 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs and flow blockage of metallic components. The program also includes activities to perform opportunistic inspections to identify hardening or loss of strength, loss of material, cracking or blistering, and flow blockage of polymeric components within the scope of subsequent license renewal, and to initiate corrective actions. Occurrences identified under the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program are evaluated to ensure there is no significant impact to the safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance or corrective actions for additional inspections, re-evaluation, repairs, or replacements is provided for locations where aging effects are found. The program is informed and enhanced when necessary through the systematic and ongoing review of both plant-specific and industry operating experience. There is reasonable assurance that the continued implementation of the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program, following enhancement, will effectively manage aging prior to a loss of intended function. Conclusion The continued implementation of the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program, following enhancement, will provide reasonable assurance that aging effects will be managed such that the components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis during the subsequent period of extended operation. PageB-177 Page 90 of 97

Surry Power Station, Units 1 and z Application for Subsequent License Renewal. Change* Notice 1 Appendix B -Aging Management Programs B2.1.39 Electrical Insulation for Inaccessible Medium~Voltage Power Cables Not Subject to 1 O CFR 50.49 Environmental Qualification Requirements Program Description The Electrical Insulation for Inaccessible Medium-Nottage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program is an existing condition monitoring program that manages the aging effect of reduced electrical insulation resistance of inaccessible medium-voltage cables {o*perating v.oltages of 2kV to 35kV) exposed to significant moisture. The program applies to inaccessible or underground non-EQ medium-voltage power cable installations (e.g., installed in buried conduits, duct banks, underground vaults, manholes, cable trenches or direct buried installations), within the scope of subsequent license renewal exposed to significant moisture. Significant moisture is defined as exposure to moisture that lasts more than three days (i.e., long term wetting or submergence over a continuous period), that if left unmanaged, could potentially lead to a loss of intended function. Power cable exposure to significant moisture may cause reduced electrical insulation resistance that can potentially lead to failure of the cable's insulation system. .Periodic actions are taken to prevent non-EQ inaccessibie medium-voltage power cabies from being exposed to significant moisture. Accessible cable conduit ends and manhole/vaults associated With cables included in this program are inspected for water coliection and the water is drained, as necessary. Manholes associated with in-scope non-EQ inaccessible medium-voltage power cables are inspected to confirm that cables are not wetted or submerged in water, cables/vaults and cable support structures are intact and dewatering/drainage systems (i.e., sump pumps) and associated alarms operate properly. This inspection and water removal is performed based on actual plant experience over time with an *inspection frequency being at least annually and.after event driven occurrences (such as heavy rain, rapid thawing of ice and snow, or flooding). Dewatering devices and associated alarms are inspected and their operation verified periodically. In-scope non-Ea inaccessible medium-voltage power cables routed through manholes, and duct banks ar.e tested to detect reduced electrical insulation resistance of the cable's insulation system. Testing that is appropriate to the application at the time of the testing is performed. Cable te~ting includes one or more proven testing methods (such as dielectric loss [dissipation factor (Tan-Delta)/power factor], AC voltage withstand, partial discharge, step voltage, time domain reflectometry, ihsulat1on resistance and polarization index, or line resonance analysis). Cable testing acceptance criteria are defined prior to each test. Cables are tested at lea~t once every six years. More frequent testing may occur based on test results and operating experience. PageB-253 Page 91 of 97

Change f\\lofice i Surry Power Station, Units 1 and 2 Application for Subsequent license Renewal Appendix B - Aging Management Pr9grams There are no submarine cables or other cabl/as designed for continuous \\ffl~tting or submergence currently in the scope of this program. Future installed (?ables of this design would be considered for inclusion in this program. NUREG-2191 Consistency The Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to *10 CFR 50.49 Environmental Qua/ifiqation Requirements program is an existing program that, following enhancement, will be consistent with NUREG-2191, Section XI.E3A, Electrical Insulation for Inaccessible Medium-Voltage P,;,wer Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements. Exception Summary None Enhancements Prior to tne subsequent period of extended operation, the following enhancement(s) will be implemented in the following program element(s):

  • Preventive Actions (Element 2)
1.

Procedures will be revised to require inspection of in-scope manho.les after event driven occurrences, such as heavy rain, rapid thawing of ice and snow, or flooding.

2.

Procedures will be revised to add a step stating that automatic or passive drainage features of manholes are operating properly. Parameters Monitored/lnspe9ted (Element,3)

3.

A procedure will be created for testing medium-voltage cable that includes a requirement for testiri_g medium-voltage c:ables that are exposed to si,gnific:ant moisture to determine the condition of the electrical insulation.

4.

Procedures will be revised to add a step to evaluate adj~sting the inspection frequency of manholes based on plant-specific operating experience over time With water collection. Detection of Aging Effects (Element 4)

5.

A new recurring event *and maintenance schedule will be created for testing the,;A" RSST cables at least once every six years.

6.

A new recurring event and maintenance schedule will be created for testing the,"B" RSST cables at least once every six years.

7.

A new recurring event and maintenance *schedule will be created for testing-the "C" RSSi cables at least once every six years. Page 92 of 97

Change Noti~ 1 Surry.Power Station. Units 1 and 2 Application for Subseq!Jent License Renewal Ap'pendix B - Aging Managem~nt Programs

8.

A new,procedure will be created for testing medium-voltage cable that includes a requirement. that the specific type of test performed will be a proven test. utilizing one or more tests such as dielectric loss (dissipation factor (Tan-Delta)/power factor), AC voltage withst~nd, partial discharge, step voltage, time domain reflectometry, insulation resistance arid polarization index, or line resonance analysis, for detecting deterioration of the insulation system due to submergence (e.g., selected test is applicable to the specific cabl~ construction: shielded and non:.shielded; and the insulation material *under test). Monitoring and Trending (Element 5)

9.

A *new procedure Will be created for testing medium-voltage cable that includes. a requirement to review visual inspection and physical test results that are trendable and repe~table to provide additional information on the rate of cable or connection insulation degradation. Acceptance Criteria (Element 6)

10. A new procedure will be created fdr testing medium-voltage cable that includes acceptance criteria for tests and inspections.

Operating Experience Summary The following examples of operating experience* provide objective evidence that the Electfica/ Insulation for lnaccess;ble Medium-Voltage Power Cables Not-Subject to 1 O CFR 50.49 Environmental Qualification Requirements program, has been, and will be effective in managing the aging effects for SSCs within the scope of the program so that their intended functions will be maintained consistent with the current licensing basis during the subsequent period of extended operation,.

1.

In May 2009, following rain, water was observed draining out of the AAC cabling lead box located outside the condensate poiishing building. A walkdown Qf \\he installation and a review of drawings was performed.. Ah inspection of the ductlines entering the-lead box discovered water in the ductlines. The ductlines were dewatered. Additiom;dly, the individual ductlines were sealed, and the 4kV cabl,es from the. MC diesel generator were entered into* the cable life cycle management plan for testing. No wetting/degradation has been observed in recent inspections.

2.

In September 2012, during an NRC review of License Renewal (LR) commitments and activities, the NRC LR review ~earn identified that the proposed method to perform an annual visual inspection for water acc1,1mulation in an in-scope man.hole may not be effective: The 'C' RSST power cable was re-routed to this manhole in April 2009. This was the only medium-voltage cable within the scope of initial license renewal. PageB-255 Page 93 of 97

Cha.nge Notice 1 Surry Power Station. Units 1 and 2 Application for Subsequent license Renewal Appendix B - Aging Management Programs It was identified that the manhole was not being periodically inspected for water accumulation. As a result, the 'inspection procedure was revised to add the in-scope manhole. Additionally, it was noted that the procedure* did not allow*for manhole entry to attempt a visual inspection of this 42 foot deep manhole. It was determined that the use of a boroscope would be effective to provide for the necessary inspection. the procedure was revised accordingly. 3, In December 201 s*, an effectiveness review of the Non-Environmental Qualification (EQ) Cable Monitoring Activity (UFSAR Section 18J.4) was performed. The aging management activity (AMA) was evaluated against the performance criteria identified in NEl 14--12 for the detection of Aging Effects, Corrective Actions, and Operating Experience program elements. The Non-Environmental Qualification (EQ) Cable Monitoring AMA includes elements of the Electrical Insulation for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Reqi.Jirements program (82, 1.37), the Electrical Insulation for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program (82.1.38) and the Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program (B2.1.3a). During this effectiveness review, timeliness of corrective action for sealing duct bank entrances for the underground 'C' RSST cables was identified. A Work Order that was created in 2011 to seal the duct bank entrances in order to prevent water and silt entry into a license renewal manhole had not been completed and there was no evaluation to allow delay of the work. Subsequently, an assessment was completed* to evaluate whether ariy license renewal commitments were compromised by delay in implementing the work order. Annual visual inspections of the same license renewal manhole between 2013 and 2017 have found water level being controlled below the level of the cables such that the cables are not exposed to .slgriificant moisture, indicating that water in-leakage has-not exceeded the capability of the sump pumps. No license renewal commitments were judged to be compromised. and it was ~0R1mendod that ~his w~rk-eraer be 13FeGessed iA aosorElanse.. vitl:i statieA *Nork n1ana§eFRem i;,raoiioes for iR:i13leffientation.Duct bank seals were installed to correct this condition during the 2018 Fall refueling outage. Results of the December 2015 effectiveness review for the other two associated aging management programs are provided in the SLRA *sections indicated above. PageB-256 Page 94 of 97

Change Notice 1 Surry Power Station. Units 1 and 2 Application for Subsequent license Renewal Appendix B - Aging Management Programs

4.

In September 2016, the periodic surveillances of an in-scope manhole for water intrusion were reviewed~ Since March 2012, when the inspection procedure was established, there has been no excessive water in the manhole, and no long term wetting of the medium-voltage cables in this manhole. The in-scope medium-voltage cables have been tested with the following results:

  • In 2011, the SBO AAC diesel cables were tan-delta tested with satisfactory results. These cables have been entered into the medium-voltage testing program.
  • In 2012, the RSST feeder cables were tan-delta tested with satisfactory results.
  • In 2015', the EOG #1 cables were meggered and Pl tested (non-shielded cable} with satisfactory results. They again were tested satisfactorily in 2017.
5.

In December 2016, a*s part of oversight review.activities, a review of procedures credited by initial license renewal AMAs was conducted to confirm the following:

  • Procedures credited for license renewal were identified
  • Procedures were consistent with the licensing basis and bases documents
  • Procedures contained a reference to conduct an aging management review prior to revising
  • Procedures credited for license renewal were identified by an appropriate program indicator and contained a reference to a license renewal document
  • Procedure changes Were completed as necessary to ensure the above items were satisfied.
6.

In November 2017, as part of oversight review activities, the Non-Environmental Qualification (EQ) Cable Monitoring Activity (UFSAR Section 18.1.4) AMA owner confirmed that AMA inspections had been performed and the inspections addressed the required SSCs consistent with the aging management activity commitments. No gaps were identified by the review.

7.

In January 2018, an aging management program effectiveness review was performed of the Non-Environmental Qualification (EQ) Cable Monitoring Activity (UFSAR Section 18.1.4). Information from the summary of that effectiveness review is provided below: The implementing procedure forthis activity includes instructions for the Electrical lnsu/at,on for Electrical Cables and Connections Not Subject to 10 CFR 50. 49 Environmental Qualification Requirements program (B2.1.37), Electrical lnsufation for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in fnstrumentatfon Circuits program (B2.1.38) and Electrical fnsulatio11 for :Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program (82.1.39). This effectiveness review summary applies to the Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program (82.1.39). PageB-257 Page 95 of 97

Change Notice 1 Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs The Non-Environmental Qualification (EQ) Cable Monitoring Activity* is meeting or exceeding the requirements of selected NEI' 14'-12,,;Aging Management Program Effectiveness," elements. Key activities of the AMA that Were reviewed included the selection of components to be inspected or tested, the inspection and testing of the components, the evaluation of the inspection and testing results, repair/replacements of components as required, and AMA document updates. Engineerlhg reports from the ioo4/2006 and 2014/2016 inspection results of manholes containing.in-scope medium-voltage cables were* reviewed to confirm inspection frequencies Were conducted at appropriate intervals and corrective actions taken: consistent with the observed condition, such as raising cables from the bottom of the manhole when they were lying in water. The review also encompassed: pertinent issues found in the Corrective Action Prowam from 2006 through 2017 for manhole water intrusion for those components within the scope of license renewal. Due* to the review of corrective actions. to address wetted or submerged medium-voltage cables, the implementing procedure was enhanced to ensure manhole visual inspections are conducted at least annually and ensure the use of boroscopes (o verify cables within the scope of license renewal were not exposed to submerged conditions when manholes cannot be ent~red. The above examples of operating experience provide objective evidence that the Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requi~ments program includes activities to perform testing and visual inspections of manholes to identify the aging effect of reduced electrical insulation resistance for non-EQ inaccessible medium-voltage cables (operating voltage of 2kV to 35kV) exposed to signi'ficant moisture within the scope of sub~equent license renewal; and *to initiate corrective actions. Occurrences identified under the Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements-program are evaluated to ensure there is no sigoificant impact to the safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance or corrective actions for additional inspections, re-evaluation, repairs, or replacements is provided for locations where: aging effects are found. The. program is informed and enhanced when necessary through the sy$tematic and ongoing review of both plant-specific and industry operating experiencE!. there ls reasonable assurance that the continued implementation of the Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not-Subject to 10 CF.R 50.49 Environmental Qualification Requirements program, following enhancement. will effectively manage aging prior to a loss of intended function. PageB.,.258 Page 96 of 97

Conclusion Surry Power Station, Units 1 and 2 Application for Subsequent License Renewal Appendix B - Aging Management Programs The continued implementation of the Electrical Insulation for Inaccessible Medium-Voltage Power Cables. Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program, following enhancement, will provide reasonable assurance that aging effects will be managed ~uch that the components within the scope of this* program will continue to perform their intended functions consistent with the current licensing basis during the subsequent period of extended operation. RageB-259 Page 97 of 97

Change Notice 1 SPS SLRA PWROG-17011-NP, REVISION 2 Serial No.: 18-448 Docket Nos.: 50-280/281 UPDATE FOR SUBSEQUENT LICENSE RENEWAL: WCAP-14535A, "TOPICAL REPORT ON REACTOR COOLANT PUMP FLYWHEEL INSPECTION ELIMINATION" AND WCAP-15666-A, "EXTENSION OF REACTOR COOLANT PUMP MOTOR FLYWHEEL EXAMINATION" Virginia Electric and Power Company (Dominion Energy Virginia) Surry Power Station Units 1 and 2}}