Initiating Events Lecture 4-1 1

Key Topics

  • NPP PRA definition of initiating event
  • Fundamental ethos: search for failures 2

Resources American Nuclear Society and the Institute of Electrical and Electronics Engineers, PRA Procedures Guide, NUREG/CR-2300, January 1983 H. Kumamoto and E.J. Henley, Probabilistic Risk Assessment and Management for Engineers and Scientists, Second Edition, IEEE Press, New York, 1996.

T.A. Kletz, Improving Chemical Engineering Practices: A New Look at Old Myths of the Chemical Industry, Second Edition, Hemisphere Publishing, New York, 1990.

H. Petroski, To Engineer is Human: The Role of Failure in Successful Design, Random House, New York, 1992.

3

NPP PRA - The What Levels

- Level 1 (core/fuel damage)

- Level 2 (radioactive release)

- Level 3 (offsite consequences)

Hazards

- Internal events (hardware, human, LOOP)

- Internal hazards (flood, fire, heavy load drops, )

- External hazards (seismic, flood, wind, )

Operating Mode

- At power

- Low power/shutdown Sources

- Core

- Spent fuel pool

- Other (e.g., dry cask storage) 4 Hazards Initiating Events Plant Damage States Source Term Groups Release Categories Offsite Consequences Level 1 Level 2 Level 3 Context for Initiating Event Analysis Risk {si, Ci, pi }

NPP PRA - The How (Big Picture) 5 Spent Fuel Pool Units All Hazards Level 1/2,3 PRA Dry Cask Storage All Hazards Level 1/2,3 PRA Integrated Site Model All Sources All Operating States All Hazards Level 1,2,3 PRA Reactor Units At-Power Internal Hazards Level 1,2,3 PRA Reactor Units At-Power External Hazards Level 1,2,3 PRA Reactor Units Low Power/Shutdown All Hazards Level 1,2,3 PRA Reactor Units All Operating States All Hazards Level 1,2,3 PRA Context for Initiating Event Analysis

The General Modeling Process - One View 6

Formulation Develop understanding Possible scenarios Key processes and parameters Modeling issues Interactions with other analyses Select scenarios for analysis Select computational tool(s)

Analysis Collect data Generic Plant-specific Build model(s)

Direct input External submodels Perform computations Interpretation Results for analyzed scenarios Implications for other scenarios

The Modeling Process - A More Detailed View 7

American Nuclear Society and the Institute of Electrical and Electronics Engineers, PRA Procedures Guide, NUREG/CR-2300, January 1983.

Sequence = Initiating Event AND Mitigating System Response Context for Initiating Event Analysis Critical First Step

Where to start? Before the storm*

Its Christmas Eve at the Bunbury Bay Nuclear Power Plant, Old Reliable to the crew and local residents, most of whom have friends or family working at the plant.

A severe Noreaster took down powerlines a month ago, but, as with past blizzards, the plant rode it out, providing needed power to the region. Most of the workers, who had put in long hours to cope with the November storm and its aftermath, are home for a well-deserved rest over the holiday, and Old Reliable is purring along with a nearly minimum crew. (Some unlucky workers are earning overtime working on the plants newer, air-cooled EDG, which is down for emergency repairs.) A low pressure area, formed in the Atlantic some two days ago, is being tracked but the disturbance is small. Although there are indications of intensification, weather forecasts provide no cause for serious alarm. Theres snow on the ground and chestnuts are roasting 8

Initiating Event Definition

  • Thanks to Pierre LeBot (EDF) for parts of this story.

Where to start? The storm hits At around 3 pm, winds in the region start to rise; blowing snow cuts visibility and trees are swaying. The plant receives a warning that the disturbance had become a storm but its intensity and direction are unclear. Considering the conditions of the roads and crew, past plant performance, and the uncertainty in the weather model predictions, the plant manager decides to alert off-duty senior staff, but not to recall any workers.

At 5 pm, the storm hits the coast. Around 8:30 pm, severe wind gusts take down multiple power lines, disrupting the grid. The plant loses offsite power and trips at 8:32, and the water-cooled EDG starts and loads as designed. At 11:16 pm, wind-driven waves, on top of severe storm surge and an abnormally high tide (a beyond-design basis hazard combination), overtop and damage the protective seawall and start flooding the pump house, endangering service water (normal and emergency). The plant (an old, isolation condenser design) starts preparing to enter SBO conditions. Fortunately, an offsite power line is recovered at 11:34. Recognizing the unreliability of the grid under storm conditions, the plant starts reviewing its procedures to stay at hot shutdown conditions until grid stability can be assured. However, offsite power remains available and the plant achieves cold shutdown early Christmas morning.

9 Initiating Event Definition

Possible Choices Event Why?

November storm Sets up plant workforce, activities, and attitudes, and offsite conditions. Could support risk-informed post-storm operations decisions Low pressure formation Natural starting point if using storm simulation modeling. Could support risk-informed early storm preparations.

Storm warning (3 pm)

Deteriorating conditions; warning triggers decision (whether to recall staff). Could support risk-informed response.

Storm hits coast Natural event for storm-oriented analysis.

LOOP Start of nuclear transient.

Pumphouse flooding Not a great choice for a literal analysis, but could be moved up to coincide with LOOP in a PRA.

10 Initiating Event Definition

- Glossary of Risk-Related Terms in Support of Risk-Informed Decisionmaking, NUREG-2122, 2013 Convention for Initiating Event 11 Initiating Event Definition

Identifying Initiating Events

  • Tools/approaches include:

- Failure Modes and Effects Analysis (FMEA)

- Hazard and Operability Studies (HAZOPS)

- Master Logic Diagrams (MLD)

- Heat Balance Fault Trees

- Review of past events

- Comparison with other studies

- Feedback from plant model

  • If its not in the model, it cant be analyzed.

Use your imagination 12 Identification Methods

but

  • Frame as a search (more active, directed than imagining)
  • Screen out unimportant events to enable practical solution and avoid distractions

- Limited analysis resources

- Risk masking from overly conservative analyses

  • Recognize challenges

- Completeness

- Data relevance (and rectifiability) 13 Identification Methods

Example for Demonstrations:

A Simple Boiler 14 Desired State Steam Flow Liquid Level MS Valve FW Pump Hot Gas

1 < < 2 Open On On

2 Open Off On

1 Closed On Off

Closed Off Off Feedwater Pump Drain Valve Level Sensor L

a1 a2 Main Steam Valve Steam Flow Sensor Hot Gas Identification Methods

FMEA - Principles Inductive approach - postulate failures and determine effects Apply to all elements in system Uses standardized terms FMECA: add criticality analysis 15 From H. Kumamoto and E.J.

Henley, Probabilistic Risk Assessment and Management for Engineers and Scientists, Second Edition, IEEE Press, New York, 1996.

Identification Methods

FMEA Partial Example (Boiler Problem)

Component Failure Mode Cause(s)

Effects Pressure Vessel Rupture a.

Overpressure b.

Impact c.

Corrosion d.

Faulty materials e.

Faulty construction f.

Faulty installation g.

a.

Stops operation b.

Hazards to operators, other components i.

Steam ii.

Flooding iii.

Missile(s) iv.

Displacement Feedwater Pump Fails to run a.

Mechanical failure (e.g.,

binding, rotor crack) b.

Clogging c.

Loss of power d.

Incorrect control signal e.

Incorrect operator action f.

a.

Stops system operation b.

Creates demand for system response

16 Identification Methods

HAZOP - Principles Extension of FMEA Includes process parameter deviations Guide words to stimulate creative thinking Used extensively in chemical process industry 17 From H. Kumamoto and E.J. Henley, Probabilistic Risk Assessment and Management for Engineers and Scientists, Second Edition, IEEE Press, New York, 1996.

Identification Methods

HAZOP Partial Example (Boiler Problem) 18 Process Parameter Deviation Effects Gas Flow No Flow a.

Stops operation b.

Creates demand for system response (stop feedwater). If response fails, could lead to overfilling and possible flooding elsewhere Gas Flow More Flow a.

Increases steam generation rate. Depending on steam flow setpoint, could trigger system shutdown.

b.

Increases water boiloff rate. If feedwater cant compensate and steam flow setpoint isnt reached, could cause dryout and gas tube rupture.

Identification Methods

Master Logic Diagram - Principles

  • Deductive approach
  • Basically a fault tree; shows how a top event can occur
  • Heat Balance Fault Tree is similar concept 19 Glossary of Risk-Related Terms in Support of Risk-Informed Decisionmaking, NUREG-2122, 2013 Identification Methods

A Classic NPP MLD 20 PRA Procedures Guide, NUREG/CR-2300, 1983 Identification Methods

MLD for a Space Application 21 Probabilistic Risk Assessment Procedures Guide for NASA Managers and Practitioners, NASA/SP-2011-3421, 2nd ed., 2011 Identification Methods

MLD Partial Example (Boiler Problem) 22 High Steam Flow Trip Insufficient Feedwater Sensor Failure Loss of FW Source Trip Logic Failure High Steam Flow Spurious Trip T3 T2 T1 Excessive Heat Pump Tripped Pump Failure Flow Path Blocked Identification Methods

Other Frameworks

  • Different representations of causality can:

- Stimulate imagination

- Facilitate communication with like-minded

  • Example: bowtie diagrams are advocated for process applications 23 W. Nelson, How Things Fail - e.g. Deepwater Horizon and Fukushima - and Occasionally Succeed, Nov. 2, 2011 Identification Methods

Operational Experience (OpE)

  • Illustrates mechanisms and complexities that might otherwise be missed
  • Examples

- Water hammer in fire main causes reactor building flood

- Lighted candle causes cable fire

- Boat wake rocks submarine and causes reactivity accident

  • OpE also can indicate where imagination might be going too far
  • Non-NPP experience is potentially valuable (e.g., see Kletz) 24 Identification Methods

Other Studies (NPP)

Loss of offsite power Plant-centered Switchyard Grid Severe weather Loss of safety-related bus Loss of instrument or control air Loss of safety-related cooling water Loss of feedwater General transient Steam generator tube rupture Loss of coolant accident Very small LOCA Small LOCA Medium LOCA Large LOCA Excessive LOCA Interfacing system LOCA Stuck-open relief valve High energy line break 25 LOCA ISLOCA SGTR Transients LOOP LO1DC LOCCW LOHVAC Example CDF Contributions (Internal Events)

Identification Methods

Including External Hazards

  • Internal events
  • Internal floods
  • Internal fires
  • Seismic events
  • External floods

Comments NPP PRA is a systems modeling enterprise => uses divide and conquer approach => caution needed at task interfaces (e.g., between initiating event analysis and event sequence analysis)

- Gaps

- Mismatches Iteration (which fuzzifies interfaces) is important. Examples:

- Initiating event analysis considers importance of postulated event; early judgments needed to start other tasks can/should be revisited

- Internal and external hazards analyses use internal events models (Lecture 6-2); can suggest model modifications based on results and insights 27

Comments (cont.)

28

  • To postulate how things might fail, first need to know how things are supposed to work =>

Initial Information Collection step (a.k.a.

Plant Familiarization) is critical

  • Checklists (e.g., based on past studies) are useful, but concept of active searching is key, especially for new systems.
  • Multiple approaches/tools provide different perspectives and can help ensure completeness.