Unmanned Autonomous Vehicles (UAV) for Decommissioning Section Number W12 Stephanie Bush-Goddard, Ph.D.

Senior Health Physicist Radiation Protection Branch Office of Nuclear Regulatory Research

Study Introduction and Goals Methodology Drone Flight Data Analysis Conclusions Agenda

Regulations and Guidance

  • 10 CFR Part 20, Subpart E
  • TEDE < 25 mrem/year and ALARA Regulatory Requirements
  • NUREG-1575: Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
  • NUREG-1507: Minimum Detectable Concentrations with Typical Radiation Survey for Instruments for Various Contaminants and Field Conditions
  • NUREG-1757: Consolidated Decommissioning Guidance Guidance Documents

Proof of Concept and Key Questions for Analysis Did observed UAV paths differ from human planned paths?

Did survey deviation impact survey results?

Were radiological measurements from human and UAV surveys significantly different?

Aurelia X6 Drone and Payload

Legend Start Path End Path Source Location Source Flight Path Background Flight Path PNNLs 3440 Outside Test Track Sources and Flight Path Source Position 2 cm Cs-137 Button/Check Source

Scanning Technique Attribute Predicted Actual Height 5-15 cm 3-100 cm Speed 0.2-1 m/s 0.2 m/s

UAV Flight Center of Gravity Determination

=

Background===

Measurements

Human Simulation

Data Logger and Detection of Sources

Q1 Results: UAV Paths vs. Human Paths?

Statistical equivalence between UAV and human paths Max slope deviation of 1.9

Q2 Results: Survey Deviation Impacts?

Velocity Variation

+/-0.3 m/s Altitude Variation Greatest for drone in all surveys Between 1.8-2.6 m/s for human and UAV Higher altitude surveys had less variation

Q3 Results: Significant Differences in Radiological Measurements?

Overall Conclusions UAV has potential in decommissioning Ludlum detectors work well in low and high altitudes Commercially available equipment able to perform surveys

Recommendations for Next Steps Optimize integration of radiation detection instruments Consider other radionuclides and detector types Address environmental condition variation in experimental development

Project Team Name Technical Need Stephanie Bush-Goddard/Vered Shaffer (deputy)/Jessica Strongin*

Program Manager/NRC COR John Tomon NRC Branch Chief Tara ONeil/Katie Wagner (deputy)

PNNL Program Manager Amoret Bunn PNNL Principal Investigator Steve Maheras Decommissioning SME (PNNL)

Tracy Ikenberry Health Physics SME (PNNL)

Harish Gadey*/Eric Becker/Dutch Dutcher/Emily Arredondo*

Radiation Detection SME (PNNL)

John Jes Smart/Kameron Markham*/Luke Placzek*/Shane Foss UAV SME (PNNL)

Jayson Martinez, Brianna Friedman*

UAV Pilot; Visual Observer (PNNL)

Deb Fagan/Moses Obiri*/Kelly OMalley*

Data Analyst (PNNL)

Josh Torgenson Payload Specialist/3D Printer Kevin Litke/Jon Ray PNNL Aviation Safety POC

  • denotes intern or co-op

Thank you.

This Photo by Unknown Author is licensed under CC BY-SA