Environ Assessment & Finding of No Significant Impact Supporting Proposed Amend to Revise Provisions of TS Re Section 5.6.1.1, Criticality - Spent FuelML17329A411 |
Person / Time |
---|
Site: |
Cook |
---|
Issue date: |
03/03/1992 |
---|
From: |
Stang J Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
Shared Package |
---|
ML17329A412 |
List: |
---|
References |
---|
NUDOCS 9203190267 |
Download: ML17329A411 (5) |
|
Similar Documents at Cook |
---|
Category:ENVIRONMENTAL IMPACT APPRAISALS
MONTHYEARML17333B1141997-10-29029 October 1997 Environ Assessment & Finding of No Significant Impact Re Exemption from Certain Requirements of 10CFR50.71(e)(4) Re Submission of Revs to Updated Final Safety Analysis Rept ML17332A4011994-10-24024 October 1994 Environ Assessment & Finding of No Significant Impact Re Util Request for Approval for Disposal of Licensed Matl Per 10CFR20,section 302 ML17332A7711994-02-0808 February 1994 Environ Assessment & Finding of No Significant Impact Re Issuance Exemption from Requirement of 10CFR55.59(a)(1) to Plant ML17331A1061993-03-16016 March 1993 Environ Assessment & Finding of No Significant Impact Re Util 930115 Schedular Exemption Request from 10CFR50,App E, W/Regard to 1993 Emergency Planning Exercise ML17329A4111992-03-0303 March 1992 Environ Assessment & Finding of No Significant Impact Supporting Proposed Amend to Revise Provisions of TS Re Section 5.6.1.1, Criticality - Spent Fuel ML17325B2221989-06-0606 June 1989 Environ Assessment & Finding of No Significant Impact Re Amend to License DPR-58,revising Tech Specs to Allow Operation of Primary Coolant Sys at Reduced Temp & Pressure Conditions to Reduce Stress Corrosion Cracking in U-tubes ML17325B1451989-02-10010 February 1989 Environ Assessment & Finding of No Significant Impact Re 880815 Application Revising Tech Specs Re Moderator Temp Coefficient,Shutdown Margin & Engineering Safeguards Actuation Requirements ML17326B4371988-08-23023 August 1988 Environ Assessment & Finding of No Significant Impact Re 880229 Request for Onsite Disposal of Contaminated Concrete Slabs ML17325A5351987-12-0303 December 1987 Environ Assessment & Finding of No Significant Impact Re 871005 Application for Amends to Licenses DPR-58 & DPR-74, Changing Name of Util from Indiana & Michigan Electric Co to Indiana & Michigan Power Co 1997-10-29
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML17326A1191999-09-10010 September 1999 NPDES Noncompliance Notification:On 990909,unnatural Turbidity Was Observed at Cook Plant Outfall 001 & 002. Caused by Bentonite Clay Being Fed Into Discharge Vaults During Molluscicide Treatment.Terminated Clay Feed ML17326A0421999-07-0909 July 1999 NPDES Noncompliance Notification:On 990707,sample Taken Showed Residual Clam-Trol CT-2 Value of 0.17 Ppm.Caused by Interruption of Clay Feed to Unit 1 Discharge Vault.Valve Was Cleared & Clay Feed Was re-established ML17326A0431999-07-0909 July 1999 NPDES Noncompliance Notification:On 990707,unnatural Turbidity Was Observed at Outfall 002.Caused by Bentonite Clay Being Fed Into Discharge Vaults During Molluscicide Treatment.Clay Feed Was Terminated on 990708 ML17325B6131998-12-31031 December 1998 Annual Radioactive Effluent Release Rept for 980101-1231 for DC Cook Nuclear Plant,Units 1 & 2 ML17335A5241998-12-31031 December 1998 Annual Environ Operating Rept for Jan-Dec 1998 for DC Cook Nuclear Plant,Units 1 & 2. with 990430 Ltr ML17326A1241998-12-31031 December 1998 Revised Page 2 to 1998 Annual Environ Operation Rept, for DC Cook Nuclear Plant,Correcting Omission in App I ML17335A1441998-07-31031 July 1998 NPDES Noncompliance Notification:On 980623,ice-making Sys Discharge Line Developed Leak & Oversprayed Containment Spillings Approx 50 Gallons.Caused by Vibration & Wear Against Line.Discharge Line Supports Have Been Redesigned ML17334B8161998-07-0808 July 1998 NPDES Noncompliance Notification:On 980617,discovered Lube Oil Discharge.Caused by Leaking Tubes Due to Corrosion of Tubes.Leaking Tubes Repaired & Established Insp/Preventive Maint Program for Lube Oil Coolers ML17334B7571998-04-27027 April 1998 NPDES Noncompliance notification:980327,boiler Condensate Spill Occurred.Caused by Small Amount of Condensate on Metal Skirting Surrounding Containment Berm.Failed Condensate Valve Was Replaced ML17334A6861998-03-13013 March 1998 NPDES Noncompliance Notification:On 980209,boiler Condensate Spill Occurred.Caused by Failed Sight Glass on Rental Plant Heating Boiler.Replaced Site Glass & Installed Plexiglass Shield Around Site Glass to Protect Operators ML17334A6941997-12-31031 December 1997 Annual Radioactive Effluent Release Rept for Jan-Dec 1997. ML17334B7671997-12-31031 December 1997 Annual Environ Operating Rept for 970101-1231 for DC Cook Nuclear Plant,Units 1 & 2 ML17334A5881997-12-0909 December 1997 NPDES Noncompliance Notification:On 971108 Plant Personnel Chlorination Sys Was Shut Down,Due to Valve Lineup Error Made During Startup of Continuous Chlorination After Shutdown.Corrected Lineup & Repositioned Valve ML17333B1141997-10-29029 October 1997 Environ Assessment & Finding of No Significant Impact Re Exemption from Certain Requirements of 10CFR50.71(e)(4) Re Submission of Revs to Updated Final Safety Analysis Rept ML17334B6201996-12-31031 December 1996 Annual Radioactive Effluent Release Rept for Period of 960101-1231 ML17334B6221996-12-31031 December 1996 Annual Environ Operating Rept for 960101-961231. W/970418 Ltr ML17333A8051996-12-31031 December 1996 Number of Personnel & Man-Rem by Work & Job Function ML17333A3881996-03-13013 March 1996 NPDES Noncompliance Notification:On 960310,continuous Ph Monitoring of Outfall 00D(turbine Room Sump)Interrupted. Caused by Electronic Failure of Monitoring Instrumentation. Grab Samples Performed & Monitor Recalibrated on 960311 ML17333A3871996-02-28028 February 1996 NPDES Noncompliance Notification:On 960226,continuous Ph Monitoring of Outfall 00D(Turbine Room Sump) Interrupted. Caused by Fouling of Ph Instrumentation Glass Electrode. Electrode Cleaned & Ph Monitor Returned to Svc ML17333A4021995-12-31031 December 1995 Corrected Annual Radioactive Effluent Release Rept for DC Cook Nuclear Plant Units 1 & 2 ML17334B5801995-12-31031 December 1995 Annual Radioactive Effluent Release Rept Jan-Dec 1995 ML17334B5871995-12-31031 December 1995 Annual Environ Operating Rept,Jan-Dec 1995. W/960424 Ltr ML17332A9791995-09-21021 September 1995 NPDES Noncompliance Notification:On 950916,unnatural Turbidity Observed at Plant Outfalls 001 & 002 During Molluscicide Treatment at Plant.Preventive Actions Not Possible Due to Detoxificaion Requirements in NPDES Permit ML17332A9551995-09-0808 September 1995 NPDES Noncompliance Notification:On 950829,hydraulic Oil Spill Occurred While Divers Using Hydraulic Brushes to Remove Zebra Mussels from Plant Screenhouse Intake Forebay Walls.Oil Absorbent Booms Deployed Into Forebay ML17332A9541995-09-0707 September 1995 NPDES Noncompliance Notification:On 950831,determined That Discharge from Outfall 00C (Heating Boiler Blowdown) Exceeded Concentration of Monethanolamine Submitted in NPDES Application Due to Valve Being Aligned in Open Position ML17332A8301995-06-0808 June 1995 NPDES Noncompliance Notification:On 950530,spill of Ethylene Glycol Occurred When Contracted Svc Technician Troubleshooting Portable Welding Machine.Ethylene Glycol Coolant Replaced W/Propylene Glycol Coolant ML17332A6991995-03-23023 March 1995 NPDES Noncompliance Notification:On 950205 to 16,33 Wild Ducks Entrained in Intake Cribs & Subsequently Collected on Intake Screens within Screenhouse.Suspect Ducks Entrained While Feeding on Zebra Mussels ML17332A6961995-03-20020 March 1995 NPDES Noncompliance Notification:On 950301,bypass Discharge from Turbine Room Sump Through Emergency Over Flow Piping Into Intake Forebay to Lake Michigan ML17334B5381994-12-31031 December 1994 Annual Radioactive Effluent Release Rept Jan-Dec 1994. W/ ML17334B5411994-12-31031 December 1994 DC Cook Nuclear Plant Units 1 & 2 Annual Environ Operating Rept Jan-Dec 1994 ML17332A4011994-10-24024 October 1994 Environ Assessment & Finding of No Significant Impact Re Util Request for Approval for Disposal of Licensed Matl Per 10CFR20,section 302 ML17331B3311994-03-30030 March 1994 NPDES Noncompliance Notification:On 940303,determined HVAC Sys Leaking Water Containing Approx 1,000 Mg/Liter Sodium Nitrite at Calculated Rate of 0.5 Gpm ML17332A7711994-02-0808 February 1994 Environ Assessment & Finding of No Significant Impact Re Issuance Exemption from Requirement of 10CFR55.59(a)(1) to Plant ML17334B5031993-12-31031 December 1993 DC Cook Nuclear Plant Annual Radioactive Effluent Release Rept for Jan-Dec 1993. W/940325 Ltr ML17334B5041993-12-31031 December 1993 Annual Environ Operating Rept Jan-Dec 1993 DC Cook Nuclear Plant Units 1 & 2 ML17331A8841993-06-0808 June 1993 NPDES Noncompliance Notification:On 930526 Chlorine Exceedance Incorrectly Stated Event Occurred on May 21 Instead of Actual Date of May 19.Licensee Apologizes for Inconvenience Error May Have Caused ML17331A1251993-03-24024 March 1993 NPDES Noncompliance Notification:On 930322,plant Personnel Discovered Small Oil Sheen at North Storm Water Outfall 001S.Oil Residue from Parking Lot Gradually Entered Lake Michigan.Oil Absorbent Booms in Place at Outfall ML17331A1061993-03-16016 March 1993 Environ Assessment & Finding of No Significant Impact Re Util 930115 Schedular Exemption Request from 10CFR50,App E, W/Regard to 1993 Emergency Planning Exercise ML17334B4721992-12-31031 December 1992 DC Cook Nuclear Plant,Units 1 & 2 Annual Environ Operating Rept,920101-1231. W/930421 Ltr ML17331A0721992-12-31031 December 1992 DC Cook Semiannual Radioactive Effluent Release Rept for Jul-Dec 1992. W/930226 Ltr ML17329A6821992-11-12012 November 1992 NPDES Noncompliance Notification:On 921109,review of Records Determined That First Quarter 1992 Samples for Stormwater Outfall 001S Not Collected.Quarterly Sampling Requirement Added to Computerized Tracking Sys ML17329A5521992-07-0202 July 1992 NPDES Noncompliance Notification:On 920630,minor Inadvertent Discharge of Treatment Chemical Clam-trol CT-1 May Have Occurred.Fire Protection Clam-trol Treatment Was Suspended Immediately & Will Not Be Resumed Until Alterations Made ML17334B4381992-06-30030 June 1992 DC Cook Nuclear Plant,Units 1 & 2 Semiannual Radioactive Effluent Release Rept,Jan-June 1992. W/920826 Ltr ML17329A5481992-06-29029 June 1992 NPDES Noncompliance Notification:On 920624,grab Sample of Outfall 002 Circulating Water Discharge Indicated TRC Concentration of 0.33 mg/1.Caused by Flow Balance Between Plant Sys.Unit 1 in Shutdown Condition ML17329A5401992-06-10010 June 1992 NPDES Noncompliance Notification:On 920606,grab Sample of Outfall 002 Circulating Water Discharge Indicated Total Residual Chlorine Above Timits.Caused by Manfunctioning Svc Water Flow Meter.Flow Meter Will Be Replaced ML17329A4111992-03-0303 March 1992 Environ Assessment & Finding of No Significant Impact Supporting Proposed Amend to Revise Provisions of TS Re Section 5.6.1.1, Criticality - Spent Fuel ML20086T9911992-01-0303 January 1992 Noncompliance Notification:On 911219,approx 400 Diving Ducks Collected in Circulating Water Sys Screenwash Baskets.Caused by Abundant Food Supply Provided by Circulating Water Discharge.Flow Rates Reduced ML17334B4501991-12-31031 December 1991 Hydrogeologic Evaluation of Cook Nuclear Plant,Bridgman, Mi. ML17334B4201991-12-31031 December 1991 DC Cook Nuclear Plant Units 1 & 2 Annual Environ Operating Rept,1991. W/920424 Ltr ML17329A4261991-12-31031 December 1991 Annual Personnel Monitoring Rept for 1991 1999-09-10
[Table view] |
Text
UN D STAT S UCLE R
REGU TORY CO MISSION INDIANA MICH GAN POWER COMPAN DONALD C.
COOK NUCLEAR P A T UNI S N
DOCK T NOS.
0-315 N
50-316 NVIRONMENTAL ASSESSMENT AND F NG 0 0 SIGNIFICANT MP CT 7590-01 The U.S.
Nuclear Regulatory Commission (the Commission) is considering issuance of an amendment to Facility Operating License Nos.
DPR-58 and DPR-74, issued to Indiana Michigan Power Company, (the licensee),
for operation of the Donald C. Cook Nuclear Plant Units I and 2, located in Berrien County, Michigan.
ENVIRONMENTAL ASSESSMENT Identification of Pro osed Action The proposed amendment would revise the provisions in the Technical Specifications (TS) relating to TS Section 5.6.l.l "Criticality - Spent Fuel,"
for both units.
Specifically, the current TS requirement to store Westinghouse Fuel assemblies with fuel enrichments of greater than 3.95 weight percent uranium-235 enrichment and burnup of less than 5,500 MWD/MTV in Region I of the spent fuel pool in a 3-out-of-4 array (one storage cell in each symmetrical array empty) is modified to allow an array of highly reactive fuel "checkerboarded" with adequately burnt fuel with no empty storage locations.
The proposed action is in accordance with the licensee's application for amendment dated February 15,
- 1991, as supplemented by letters dated October 8, 1991 and January 14, 1992.
9203l90267 920306 PDR ADOcx os0003is I'P PDR
The Need for the Pro osed Action The proposed change to the TS is required in order to provide the licensee the ability to store fresh fuel in the spent fuel pool, to provide easier fuel handling operations and to optimize the available storage space in the spent fuel pool racks.
Environmental Im acts of the Pro osed Act The Commission has completed its evaluation of the proposed revision to the TS and,concludes that the proposed change does not involve a significant hazards consideration.
The proposed amendment would modify the current TS requirement which allows storage of fuel assemblies with fuel enrichments of greater than 3.95 weight percent uranium-235 and burnup of less than 5,500 MWD/MTV in Region I of the spent fuel pool in a 3-out-of-4 array to allow an array of highly reactive fuel "checkerboarded" within adequately burnt fuel with no empty storage locations.
The storage of the higher enriched fuel in the above proposed pattern would not significantly increase the probability or consequences of any accident previously analyzed.
Since the proposed change does not increase the probability or consequences of an accident, no changes are being made in the types or amounts of any radiological effluents that may be released
- offsite, and there is no significant increase in the allowable individual or cumulative occupational radiation exposure.
Accordingly, the Commission concludes that this proposed action would result in no significant radiological environmental impact.
With regard to potential non-radiological impacts, the proposed change to the TS involves a change in the installation or use of a facility component located within the restricted area as defined by 10 CFR Part 20.
The proposed change does not affect non-radiological plant effluents and has no other environmental impact.
Therefore, the Commission concludes that their are no
significant non-radiological environmental, impacts associated with the proposed amendment.
lternative to the P
o osed Act Since the Commission concluded that there are no significant environmental effects that would result from the proposed action, any alternatives with equal or greater environmental impacts need not be evaluated.
The principal alternative would be to deny the requested amendment.
This would not reduce environmental impacts of plant operation and would result in reduced operational flexibility.
Alternative Use of Resources This action does not involve the use of any resources not previously considered in the Final Environmental Statements for the Donald C. Cook Nuclear Power Plant Units I and 2, dated August 1973.
A encies and Persons Consulted The NRC staff reviewed the licensee's request and did not consult other agencies or persons.
FINDING OF NO SIGNIFICANT IMPACT Based upon the foregoing environmental assessment, we conclude that the proposed action will not have a significant effect on the quality of the human environment.
Accordingly, the Commission has determined not to prepare an environmental impact statement for the proposed license amendment.
For further details with respect to this action, see the application for amendment dated February 15, 1991 and supplements dated October 8,
1991 and January 14, 1992, which are available for public inspection at the Commission's
Public Document
- Room, 2120 L Street, N.W., Washington, D.C.
and at the Maude Preston Palenske Memorial Library, 500 Market Street, St. Joseph, Michigan 49085.
Dated at Rockville, Maryland, this 3rd day of March 1992.
FOR THE'NUCLEAR REGULATORY COMMISSION hn F.
S a g, Acting Director roject D>rectorate III-1 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation