GE Nuclear Energy TECHNICALMODIFICATIONSSERVICES GE-NE-523-B13-01869-043, Rev. 0 April 1997 ASSESSMENT OF THE VERTICALWELD CRACKINGON THE NMpl SHROUD Prepared for Niagara Mohawk Power Company Prepared by 1
GE Nuclear Energy 175 Curtner Avenue San Jose, CA 95125 9704i0024b 970408 PDR ADQCK 05000220 P
ba I
L
GENudrar EnmityProprktary T+ormusEws GE-bE-B1$-01869-043, Ro.0 ASSESSMENT OF THE VERTICALWELD CRACKING ON THE NMpl SHROUD Apni 1997
'ng Fellow H.. Mchta, Pancipal Enginccr
.C Preparedby:
R.
orn, Engineering Feihw McAllistcr,Manager Reactor Internals Management Revievedby:
T. A. Caine, Project Manager Engineering and Licensing Consulting Services Approved by:
G. L. Hayes, Manager Engineering and Licensing Co ting Services
V 1
GE-NE-B13-01869-043, Rev.0 IMPORTANTNOTICE REGARDING CONTENTS OF THIS REPORT Please read carefully The only undertakings of the General Electric Company (GE) respecting information in this document are'contained in the contract between Niagara Mohawk Power Corporation and GE, and nothing contained in this document shall be construed as changing the contract.
The use of this information by anyone other than Niagara Mohawk Power Corporation, or for any purpose other
~
than that for which it is intended is not authorized; and with respect to any unauthorized use, GE makes no representation or warranty, express or implied, and assumes no liability as to the completeness, accuracy, or usefulness ofthe information contained in this document, or that its use may not infringe upon privately owned rights.
4s I
I
GF 14E-B13-01869-043, Rev.0 EXECUTIVE
SUMMARY
During the current refueling outage (RFO 14) at the Nine Mile Point Unit 1 (NMP1)
Station, cracking was detected in the vicinity of vertical welds of the core shroud.
The cracking was detected by inspections performed in accordance with industry recommendations.
This report describes the evaluations of the vertical weld cracking.
Based on evaluations which considered bounding crack growth rates and conservative crack sizing assumptions continued operation is justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months).
Following the initial finding of the vertical weld indications, extensive inspections using automated ultrasonic (UT) and enhanced visual (EVT) examination techniques were performed to fully characterize each shroud vertical weld.
Additional automated examinations were also performed on selected shroud horizontal welds however, since the shroud is supported by a tie rod repair which was installed in RFO 13 based on the assumption ofthroughwall cracking of horizontal welds (H-1 through H-7) as the design basis, no additional evaluation ofhorizontal weld inspection results is required.
A detailed evaluation was performed to determine the structural significance of the indications found in the vertical welds.
Seveial conservative assumptions were made in the analysis:
~
No credit was taken for any portion of horizontal welds; it is assumed that each section of the shroud is a &ee standing cylinder.
Thus, the presence of horizontal weld cracking has no impact on the vertical weld crack assessment,
~
A bounding crack growth rate of 5 x 10'nches per hour has been assumed.
Field w
data and predictive models show that this is bounding even with irradiation effects.
Furthermore, because of the excellent water chemistry at NMP1 (reactor water conductivity (0.1 pS/cm) the actual crack growth rates are expected to be much
- lower,
~
Alluninspected regions are postulated to be cracked throughwall,
~
Allowance is made for crack sizing uncertainty in detected flaws.
~1 l I d
\\
1 A
-Ot t ly
GE-NE-B13-0j869-043, Rev.0 The results of the fracture mechanics analyses summarized in the table below show that continued operation can be justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months).
The results ofthe thermal hydraulic evaluation showed that even with postulated through wall cracking of the vertical welds, the resulting leakage has no safety impact.
Furthermore, since the vertical weld cracks are within the allowable sizes, they have no impact on the effectiveness ofthe shroud repair which structurally replaces the horizontal welds.
Based on the evaluation presented, continued operation can be justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months) and all ofthe required safety margins willbe maintained.
tt-2 V-7 V-tt V-9 V10 V-11 V-12 V-1$
3 V-1tt Hot to eeele NMP1 Core Shroud Welds Weld ID;-
V-3 V-4 V-7, V-8 V-9, V-10 V-11, V-12 V-15, V-16 Zvaluation Period
~
'6,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> (> 24 months) 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (- 16 months) 16,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> (> 24 months) 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (- 16 months) 16,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> (>24 months) 16,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> (>24 months)
itd
~ I ll
GE-NF B13-0l869-043, Rev.0 TABLEOF CONTENTS
- 1. BACKGROUND
- 2.
SUMMARY
OF INSPECTION FINDINGS
- 3. PROBABLE CAUSE OF CRACKING
- 4. CRACK GROWTH ASSESSMENT
- 5. STRUCTURALMARGINASSESSMENT
- 6. THERMALHYDRAULICSASSESSMENT
- 7. OVERALLSAFETY CONCLUSION 4
13 33 37
- 8. REFERENCES 38 APPENDIXA EFFECT OF TIE RODS ON VERTICALWELD STRESS APPENDIXB CRACK GROWTH RATE BASED ON THE GE THEORETICAL MODEL A-1 B-1 APPENDIX C SHROUD INSPECTION
SUMMARY
C-1
sl
~
~
I
~ '
~
~ ~
GE-NE-B13-01869-043, Rev.0
1.0 BACKGROUND
During the current refueling outage (RFO 14) at the Nine Mile Point Unit 1 (NMP1) Station cracking was detected in the vicinity of vertical welds of the core shroud.
Figures 1-1 and 1-2 show a detailed view of certain shroud weld locations.
This cracking was detected by inspections performed in accordance with industry recommendations as described in the BWRVIP Guidelines for Reinspection ofCore Shrouds (Reference 1).
In March of 1995 (RFO 13), a GE designed tie rod repair was installed on the shroud.
The I
purpose of the tie rod repair was to provide adequate support to allow the shroud to perform its function under normal operation and accident conditions with postulated through wall cracking at horizontal welds (H-1 through H-7). The tie rod repair has been demonstrated to have no impact on the cracking that has been detected on shroud vertical welds (See Section 3.1).
I During RFO 13, consistent with recommendations for the installation of the repair, visual inspections were performed on limited areas ofthe shroud vertical welds in the core region from the inside ofthe shroud. No cracking was detected.
Since the inspections performed in RFO 13, the BWRVIP has issued guidelines for reinspection ofthe shroud (Reference 1). The recent inspection was performed according to these guidelines, and unlike the previous vertical weld inspection in RFO 13, it focused on a sample inspection from the outside diameter (OD) ofthe shroud.
Cracking was initiallydetected at the V-10 weld.
The inspection scope was then expanded to include accessible areas of all vertical welds.
This inspection scope expansion detected cracking at other shroud vertical weld locations.
The purpose of this report is to assess the safety consequences of cracking detected at vertical shroud welds on the operation ofthe NMP1 Station.
I 4
pre
GF IIE-BI3-0I869-043, Rev.0 H<<1+
H-2W WH-3
+H-4
~H 6A-
~H6B-H7-Reactor vessel~
Not to scale Figure 1-1 NMP1 Shroud Weld Locations, Cross Sectional View
~ I H1 i
tf
\\
IP I
GE-NF BI3-01869-043, Rev.0 V-7 V-3 H-2 H-3 V-8 V-9 V-10 H-5 V-11 V-12
-13 V-15 H-7 V-16 Not to scale Figure 1-2 NMP1 Shroud Weld Locations
Fa
GE-iVE-B13-01869-043, Rev.0 2.0
SUMMARY
OF INSPECTION FINDINGS 2.1 Previous Inspections During RFO 13 limited inspection of shroud vertical welds V-9, V-10, V-11, and V-12 was performed by enhanced visual examination techniques.
The exam was performed on the inside diameter ofthe shroud and the coverage included a six inch portion of the welds at the location of the intersection of horizontal weld H-5. At that time the inspection scope was considered adequate because ofthe limited reported incidences of vertical weld cracking and the large flaw tolerance ofvertical welds. During that examination, no cracking was detected on welds V-9, V-10, and V-11. Weld V-12 was not located. In addition, examination ofring segment welds V-5 and V-6 was attempted, however these welds were not located.
These results are summarized in Table 2-1. It should be noted that these regions examined during RFO 13 showed no indications during the recent inspections conducted during RFO 14.
2.2 Recent Inspection Results for Shroud Vertical Welds The recent inspections were performed in accordance with BWRVIP guidelines for reinspection of the shroud (Reference 1).
These guidelines require visual inspection from the outside diameter (OD) surface or inside diameter (ID) surface, of 25% of the equivalent length of all vertical welds.
The planned inspection scope included portions of vertical welds V-9 or V-10, and V-11, and either ring segment welds V-5 or V-6, (contingent upon locating these welds) from the outside diameter.
Cracking was initiallydetected at the V-10 weld.
The inspection scope was then expanded as required by the BWRVIP guidelines to include accessible areas of each vertical weld.
Extensive examinations were then performed to fully characterize the shroud vertical weld cracks on both the inside diameter and outside diameter of the shroud.
Both ultrasonic (UT) and enhanced visual examination (EVT) techniques were used to achieve maximum characterization of the vertical weld regions.
These examinations were performed in accordance with BWRVIP Examination Guidelines (Reference 2).
The current inspections revealed fairly significant cracking on welds V-4, V-9, V-10, relatively minor cracking on welds V-3, V-12, V-15, and V-16, and no cracking on the accessible regions
4t,
+l
GF lVF BI3-0l869-043, Rev.0 ofwelds V-7, V-8, and V-11.
A summary ofthese examinations are provided in Table 2-2. A detailed description ofthe scope and findings are provided in Appendix C.
Examinations were performed in an attempt to locate ring segment welds V-5 and V-6 using eddy current and visual inspection techniques.
The inspections to date ofthe accessible areas of the ring could not locate the vertical welds, but found no cracking either.
Additional examinations were also performed on selected horizontal welds however, since the shroud is supported by the tie rod repair which assumes through wall cracking of horizontal welds (H-1 through H-7) as the design
- basis, no additional evaluation of horizontal weld inspection results is required. A summary ofthe horizontal weld inspections is also provided in Appendix C.
I C
4
~ ~
~.II u
I I
b
~\\
I-I ~
~ I
GF NF BI3-01869-043, Rev.0 Table 2-1 Summary ofPrevious Shroud Vertical Weld Inspections (RFO 13)
Weld V-9 V-10 V-11 V-12 Inspection Coverage 6" fromH-5 6 "from H-S 6 "from H-5 6 "from H-S ID or OD ofshroud ID ID ID ID Exam Type Enhanced visual, EVT-1 (Ref. 2)
EVT-1 EVT-1 EVT-1 Results No Indications No Indications
'o Indications Weld not located
h 4
I
'1
%1 'le
GE-NF BI3-01869-043, Rev.0 Table 2-2 Summary ofRecent Shroud Vertical Weld Inspections (RFO 14)
Weld V-3 V-5 ring V-6 ring V-7 V-8 V-9 shell V-10 V-11 V-12 V-15 V-16 Weld Length (in) 31.25 31.25 18.5 18.5 90.12 90.12 63.5 63.5 22.13 22.13 Inspection Coverage" 15" Left 15" Right 22" Left I I n Right Not located Not located 9" Left 11" Right 5 5" Left 9.5" Right IPP%
80" IPP%
84>7 100% OD 50% ID 100% OD 5P% ID 11" Left II n Right 1PP%
10 5" Left 20" Right Shroud ID/OD OD OD NA NA OD OD ID and OD OD ID and OD OD ID and OD ID and OD OD OD OD Exam Type UT UT NA NA UT UT EVT-1 UT EVT-1 UT EVT-I EVT-1 UT EVT-I UT Flaw Length 1.5" ID, Right HAZ 0.8" OD, Right HAZ 22 "IDLeft HAZ, 1.5 "IDRight HAZ NA NA No Indications No Indications Indications on over 90% OD right HAZ Minorcracking on OD left side and on ID both sides Numerous indications on OD, Left HAZ Two minor flaws on ID, Right HAZ Cracking on OD, Right HAZ Cracking on ID, Left and Right HAZ Flaws detected on > 80% on OD, Right HAZ Flaws detected on > 10% on OD, Left HAZ No Indications 6" OD, Right HAZ 6"
ID, LeftHAZ 2.2" ID, Right HAZ
.75" OD, LeftHAZ 5" ID Left HAZ 4" ID Right HAZ 3" ID Left HAZfrom right side exam The inspected regions indicated on each side ofthe weld are not necessarily coincident, hence the integrated inspection coverage may be less than indicated, but has been taken into account in determining the uncracked ligament length.
I
~
4U t5 4
GF NF Bl3-01869-043, Rev.0 3.0 PROBABLE CAUSE OF CRACKING It is believed that the cause of shroud vertical weld cracking is Intergranular Stress Corrosion Cracking gGSCC).
The stresses that cause cracking in vertical welds are weld residual and fabrication stresses and to a lesser extent the stress resulting from internal pressure, which is hoop stress.
Although the tie rod repair is not expected to add any additional hoop stress to the vertical welds, a detailed analysis was performed to demonstrate this.
The results of this evaluation are summarized below.
A discussion of the overall SCC susceptibility of vertical shroud welds is also provided.
3.1 Effect ofTie Rod Loads A three dimensional finite element analysis was performed to demonstrate that the thermal preload associated with the tie rod shroud modification has a negligible impact on the potential V
for crack growth in the shroud vertical welds.
The NMP1 shroud modification consists of four sets oftie rod assemblies that are mechanically and thermally preloaded with sufficient force to prevent separation of the shroud sections at the locations of horizontal welds under normal operating pressures.
This tie rod preload introduces a vertical compressive stress.
The stresses that can cause vertical weld cracking are the weld residual stress and to a lesser extent the stress resulting from internal pressure, which is hoop stress.
The three dimensional finite element analysis showed that any hoop stress induced at the vertical welds due to tie rod compression is negligible. The details ofthis analysis are provided in Appendix A. Based on this analysis it is concluded that the shroud tie rod modification did not cause shroud vertical weld cracking.
3.2 Susceptibility to Intergranular Stress Corrosion Cracking gGSCC)
It has been recognized that all BWRs could be affected to some extent by IGSCC of the core shroud.'he critical factors that can affect cracking are the following: operating time, coolant conductivity, material carbon content, orientation (short transverse plate orientation exposed to coolant), fabrication related surface cold work, neutron fluence, and stresses due to welding and fabrication as well as operating stresses.
These factors that affect IGSCC apply to both the horizontal and vertical welds in the shroud. They also have been used as a guide for establishing the timing of shroud weld inspections which have been performed over the last four years at a number of operating BWRs.
The focal point for inspections has been the shroud horizontal welds based on the initial observations ofcracking.
I
GE.ÃF B13-0l869-043, Rev.0 The experience in BWRs has shown that IGSCC initiation and growth is related to operating time.
The initiation process is a stochastic process and with time the probability of cracking increases.
This process can be accelerated ifthe water conductivity is higher because impurities aid crack initiation and accelerate crack growth. The characteristics ofthe coolant environment are also known to promote IGSCC on both the outside and the inside of the shroud.
Although NMP1 has experienced long operating times and relatively higher reactor conductivity values in the early operating years, recent operation has been with excellent water chemistry as shown by the low values ofreactor water conductivity in the past operating cycle (< 0.1 NS/cm).
The material susceptibility can be influenced by several factors.
The likelihood of sensitization occurring in the heat affected zone (HAZ) during the welding process is directly related to the carbon level of the stainless steel materials used.
Type 304 stainless steel material with greater than 0.04% carbon was consistently used in the earlier plants.
The carbon content in the Type 304 SS materials used to fabricate the NMP1 shroud ranged from 0.042 to 0.062%.
The susceptibility ofthe material is also related to the amount ofsurface cold work present.
For NMP1, portions of the shroud were subjected to cold working. By itself, the cumulative cold work from the different stages of fabrication can have a marked effect on crack initiation. Cold working can also introduce martensite, which will synergistically harden the surface and will sensitize over time at the operating temperatures.
Another factor that contributes to IGSCC is stress.
The welding process introduced high residual stresses in the shroud welds. These residual stresses have been shown to vary in magnitude over the length of the welds, and are often found to reach the yield strength of the plate material.
Fabrication can also introduce fit-up stresses.
The largest fit-up stress would be expected in the last step of the assembly with the manufacture of the H-4 weld which has exhibited some cracking.
The final factor is that of irradiation.
Irradiation can affect the material's susceptibility throughout the thickness, with expected slightly larger effects on the inside surface.
The material's susceptibility is expected to increase from the material's initial sensitization thereby further promoting IGSCC in the locations of highest residual stress and cold work. However, irradiation also reduces the weld residual stresses, which has the effect of slowing crack growth rates.
GE-JVE-BI3-0I869-043, Rev.0 In summary, the Nine Mile Point Unit 1 shroud horizontal and vertical welds are clearly susceptible to IGSCC. The high carbon Type 304 stainless steel material was initiallysensitized by the welding process.
The material's susceptibility was further enhanced by surface cold work and surface strains from the fabrication processes.
Irradiation would also add to the susceptibility over the operating time.
Finally, the tensile surface residual stresses and surface fabrication stresses led to IGSCC initiation.
10
r4 lo
'4i V
1 g, 44 1 "I, 1
GE-HE-B13-0I869-043, Rev.0 4.0 CRACK GROWTH RATE ASSESSMENT The crack growth rate in the vertical welds for the next cycle of operation was predicted using several methods.
The following four methods were used: (1) the NRC accepted K-Dependent curve, (2) the BWRVIP correlation (Reference 3), (3) the PLEDGE correlation, and (4) the SKI crack growth model (Reference 4).
The calculations were performed for a range of stress
.intensities.
For the BWRVIP and PLEDGE correlations, a reactor water conductivity equal to 0.1 pS/cm, an ECP of200 mV (SHE), and an initial sensitization (EPR) equal to 15 C/cm'ere used.
The results ofthese calculations are provided in Table 4-1.
I The NRC bounding crack growth rate is characteristic of higher reactor water conductivity environments (-0.3 pS/cm). Improvement in the reactor water conductivity can reduce the crack growth rate significantly. The reactor water conductivity at NMP1 for the year 1996 was on the average 0.09 pS/cm.
This value indicates that at present the water chemistry is excellent and is one of the best in the BWR fleet.
Assuming that this conductivity is maintained for the next cycle, the predicted average crack growth rate is expected to range from 1 x 10'n/hr to 2.3 x 10
'n/hr (for an average stress intensity across the thickness ofthe plate equal to 20 ksiIin). These rates are much less than the NRC bounding rate of5 x 10'n/hr.
Irradiation can affect crack growth rates and was not explicitly considered in the crack growth predictions except for the BWRVIP correlation which was benchmarked by the crack growth data measured on shroud welds for various range offluence.
An evaluation was performed that compares the GE PLEDGE model predictions for unirradiated material to the predictions for irradiated materials at these same values of reactor water conductivity, ECP, and initial sensitization.
This comparison shows that at fluence levels expected for BWR shrouds the predicted crack growth rate is comparable for both the unirradiated and the irradiated models.
The similarity in'rates can be attributed to offsetting effects. While the irradiation increases the susceptibility of the material (EPR increases), it also causes relaxation of the weld residual stresses reducing the driving force for crack growth.
Because the radiolysis effects are included through ECP, the unirradiated PLEDGE model can be used to predict the crack growth rate for these conditions.
For completeness, the details of the irradiation evaluation are provided in Appendix B. This evaluation (Refer to Figure B-12) also shows that for the expected reactor water conductivity, ECP, and EPR accounting for irradiation, the crack growth rate over the range of shroud fluences is bounded by the NRC bounding crack 11
k, h
't L
CC i
h 4'
4'
GF NF Bl3-0l869-043, Rev.0 growth rate of 5 x 10'n/hr. Consistent with the different models, the crack growth rate is expected to be less than this value based on field data from operating plants.
Finally, UT data obtained during the current outage (RFO 14) for the H-8 crack that was detected and measured in the 1995 outage (RFO 13) has shown that the crack has not grown.
This provides additional data to support that the crack growth rate is expected to be much lower than the NRC bounding rate.
Table 4-1 Predicted Crack Growth for Different Models Model Stress Intensity
= 10ksi-in'RC K-Dependent Curve (Upper Curve) 5 x10 in/hr BWRVIP Correlation*
1.6x10 in/hr PLEDGE*
4.2x10 in/hr SKI Crack
~ Growth Model*
1.7x10 in/hr Stress Intensity
= 15 ksi-in'.2 x 10'n/hr 3.8 x 10 in/hr 1.1 x 10'n/hr 5.7 x 10 in/hr Stress Intensity
= 20 ksi-in2 2.3 x10'n/hr 7.1x10 in/hr 2.3 x 10'n/hr 1 x 10'n/hr Stress Intensity
= 25 ksi-in'n 3.7 x 10'n/hr 1.1 x 10'n/hr 4.0 x 10'n/hr 1.9 x 10'n/hr Bounding Crack Growth Rate Used by the Industry = 5 x 10 'n/hr
- Conductivity= 0.10 pS/cm; ECP = 200 mV, SHE; InitialSensitization = 15 C/cm'2
I
\\'
L+
GE-NF B13-01869-043, Rev.0 5.0 STRUCTURALMARGINASSESSMENT The shroud repair that w'as implemented for assumed throughwall cracking of shroud horizontal welds does not require the vertical welds to be crack &ee.
The repair allows the presence of vertical weld cracks, as long as the crack lengths are less than the allowable flaw sizes or as long as the structural integrity of the vertical weld can be demonstrated.
Therefore, assuming that the vertical flaw sizes are smaller than the allowables or that structural integrity can be demonstrated, the validityofthe tie rod repair modification is maintained.
I The primary stress which could cause vertical weld failure results from the internal pressure.
Consistent with ASME Code practice (Appendix C,Section XI), internal pressure is the only load to be considered for axial cracks.
Other loads such as seismic have negligible impact and need not be considered.
The value ofthe internal pressure varies from plant to plant, but'is typically small (less than 15 ysi above the core plate for normal operation).
The allowable flaw sizes consider the internal pressures under all conditions - normal, upset, and accident events, with the appropriate safety factors. Typically, the allowable crack sizes are large and approach and/or exceed the length ofthe weld itself, indicating large crack tolerance.
No credit is taken for the horizontal weld integrity in determining the allowable vertical weld flaw sizes.
The horizontal welds are assumed completely cracked through-wall, 360', and the cylinder between any two horizontal welds is assumed to be 'stand-alone'.
The calculations also assume simultaneous cracks at the diametrically opposite welds in a given cylinder.
Furthermore, the cracking is assumed to be through wall. Both LEFM and limitload are considered in developing the allowable flaw sizes.
The actual allowable flaw size is the lower ofthe allowables for each of the two methods.
The required minimum ligament calculations also include allowances for crack growth and inspection uncertainty.
Multiple cracking ofvertical welds is not a significant concern since the analysis assumes that the upper and lower horizontal welds are completely cracked, and treats each cylinder independently.
Multiple cracks in a single weld also do not pose any concern since the fracture analysis includes proximity effects and also crack growth to account for possible linkingoftwo separate'cracks.
The shroud repair includes the consideration of multiple fullycracked horizontal welds. Therefore, as long as the allowable vertical flaw size within each cylinder is not exceeded or the structural integrity of each vertical weld within each cylinder can be demonstrated, the presence of multiple vertical weld cracking is not a concern.
13
~%
~
~
GF le BI3-0l869-043, Rev.0 This section first presents the details ofa screening criteria analysis which gives the required value of the uncracked ligament length (difference between the length of weld and the allowable flaw size) at each ofthe vertical welds in the shroud, assuming that regions with indications are cracked throughwall. Ifthis criteria length is not satisfied at a shroud vertical weld, a more detailed fracture mechanics analysis is necessary to demonstrate the integrity of a vertical weld with indications.
5.1 Required Uncracked Ligament Lengths by Screening Criteria For this calculation it is conservatively assumed that the different sections of the shroud are in fact free standing cylinders (i.e., fullycracked circumferential welds). With this assumption, it is possible to determine the required uncracked weld length at each of the vertical welds in the shroud.
Allowable vertical weld flaw sizes are based upon a set of reactor internal pressure differences.
Table 5-1 documents the pressure differentials used in the calculation (Reference 5).
Allowable shroud vertical crack lengths were calculated based on both linear elastic &acture mechanics (LEFM) and limit load analysis.
The high fluence region where there is potential irradiation embrittlement is limited to the shroud section between horizontal welds H-3 and H-6a.
Therefore, both LEFM and limit load'analysis were used for vertical welds in this region.
Specifically, LEFM was governing for the welds V-9, V-10, V-11, and V-12 and limitload was governing for welds V-7, and V-8. The vertical welds in other regions were governed by limit load analysis.
Both methods ofanalysis are described below.
14
V 0
GE-NE-BI3-01869-043, Rev.0 5.1.1 Linear Elastic Fracture Mechanics (LEFM)
The stress intensity factor for a through thickness axial crack oflength 2a, in an infinite cylinder is given by:
K=Mcz ~ma, where o is the nominal hoop stress, and M is a factor that accounts for curvature effects, and is given by (Reference 5):
M=(1.0+1.25%,) '
0.6 + 0.9A, X = a/4(Rt) for 0.0 < X, <1.0 for 1.0 < X < 5.0
[2b]
[2a]
[2c]
where 'a's the half crack length, as defined above; 'R's the mean radius ofthe shroud; and
't's the shroud thickness.
Equation 1 assumes a cylindrical shell of infinite length (Figure 5-la).
This is a reasonable assumption for the realistic cases where limited cracking (part through cracking) is observed.
With this assumption, in most cases the allowable through wall crack length exceeds the length of the weld seam itself, confirming the large crack tolerance for vertical welds.
However, the design postulated for the shroud repair assumes that each circumferential weld has 360'hrough thickness cracking.
This essentially means that each shell course between two horizontal welds should be considered as a separate,
&ee standing finite width cylindrical shell (similar to a drum open at both sides).
In order to account for the finite width of the shroud section being considered, a finite width correction factor given by Isec (na/2b) is applied (Figure 5-lb). This is based on correction factors for through thickness cracks in plates (Reference 6), and when used in conjunction with the curvature correction factor for the shell provides a
reasonable representation for a through thickness crack in a finite width cylindrical shell.
The final form ofK used for this analysis becomes:
J:=cr,~m M sec-2b
[3]
where 2b is the height ofthe shroud section being considered.
15
h a) n)
S
'I
GF jVE-BI3-01869-043, Rev.0 The calculated stress intensity factor when multiplied by the appropriate safety factor (3 for normaVupset conditions and 1.5 for emergency/faulted conditions) can be compared with the available fracture toughness of 150 ksiIin and the allowable through wall crack length (with the required safety factor) can be determined.
For example, for vertical welds V-9 and V-10, the allowable through wall crack length was determined to be 75.4 inches (or a = 37.7 in.). For this case, the value of factor X per Equation (2c) is [37.7/l(179*1.5/2)] or 3.25.
The factor M per Equation (2b) is then 3.52.
The value ofK is then calculated as shown below:
Z = 1.969ksi~+37.7in 352 sec 149 7ks.i gin
Ã'7.7ln 90.12in f4)
The stress 1.969 ksi corresponds to the calculated hoop stress for 22 psi (faulted condition) including the safety factor of 1.5.
This means that an allowable flaw size of 75.4 inches is acceptable.
As expected, because of the finite width cylinder assumption, the allowable crack length is less than the width of the shell course for V-9 and V-10, in this case 90.12 inches for Nine Mile Point Unit 1. Alternatively, the required uncracked ligament is 90.12-75.4 = 14.72 inches.
The required ligament is increased when the effects of NDE uncertainty and crack growth are included.
5.1.2 LimitLoad Analysis The limitload analysis applies to all welds and the allowable crack size is the smaller ofthe limit load and LEFM (where applicable) crack lengths.
The limit load calculations were performed using concepts similar to those described in Section XI, Appendix C of the ASME Code.
For the limitload analysis, the minimum required ligament is calculated as the uncracked section of the weld needed to resist a force due to the pressure differential across the shroud (Figure 5-2).
This pressure P,
acts upon a
16
4j
~ 'I I
GE-NE-B13-01869-043, Rev.0 projected area D*Lon the shroud, where D is the inside diameter ofthe shell segment, and L is the height ofthe shell course.
Therefore, P.D L=2. ~ t
((r, (SF t:51 where err is the flow stress (assumed to be equal to 3S where S is the ASME Code allowable design stress intensity, equal to 16.9 ksi for the shroud material at 550'F), SF is the safety factor,
~ is the required uncracked ligament length, and t is the thickness ofthe shroud.
This assumes that the entire weld except for the ligament has through thickness cracking. It also considers, conservatively, cracking on both sides as shown in Figure 5-2.
Rearranging Equation 5 and noting the definition ofhoop stress, the followingresults:
P D L
SF = ~
, 2t (zr L
SF cr = ~
m CZf
[7]
where o is once again the nominal hoop stress for this shell segment.
In determining the required uncracked ligament, the bounding case of normaVupset conditions (SF = 3.0) and faulted conditions (SF = 1.5) should be considered.
As stated earlier, the analysis for the required ligament is conservative since cracking is assumed on both sides.
5.1.3 Required Uncracked Ligaments I
Table 5-2 shows the allowable crack length as well as the required uncracked ligament lengths for each vertical weld. Welds V-7 through V-12 were evaluated using both LEFM and limitload methods.
LEFM was controlling for welds V-9 through V-12, and limitload was governing for all other welds.
The recent BWRVIP criteria for reinspection of shrouds (Reference 1) recommends that allowances for crack growth (based on an assumed crack growth rate of 5 x 10
'n/hr) and uncertainty in the inspection be added to the required uncracked ligaments.
Assuming 8000 hot operating hours per year and a two year cycle, the adder for growth in the crack length is (5 x 10'n/hr x 8000 hr/year x 2 years) x 2 =1.6 inch where the factor of two 17
Ill t
1>
1
~
t II l
~f
GE-NE-BI3-01869-043, Rev.0 accounts for crack growth at two crack tips. The BWRVIP criteria also recommends adding an inspection uncertainty factor to each end ofthe observed indication length based on BWRVIP-03 (Reference 2).
The uncertainty factor is (0.372")x 2 or 0.75 inch for ultrasonic examination (UT). Essentially, this means that the required uncracked ligament length be increased by (0.75
+ 1.6) or 2.35 inch to account for the crack growth and UT inspection uncertainty. Similarly, for enhanced visual examination, the uncertainty factor is (1.2") x 2 or 2.4 inch, thus the required uncracked ligament length be increased by (2.4+ 1.6) or 4.0 inch to account for the crack growth and EVT inspection uncertainty Table 5-2 Column 5 lists the calculated values of required ligament lengths for various vertical welds. A comparison of these values with the values determined by the examinations of these welds is discussed next.
Cracking ofradial ring welds was separately evaluated and found to have negligible impact. The only effect ofradial ring weld cracking is on the thermal preload but it was found that even with 90% ofthe weld assumed to be cracked, the effect on preload was insignificant. Therefore ring weld cracking is not significant from a structural viewpoint and no inspection is required.
Nevertheless, attempts were made to inspect the V-5 and V-6 ring welds using eddy current and visual techniques.
The inspection of the accessible areas of the entire ring could not locate the welds but found no cracking either.
5.2 Comparison with Required Uncracked Ligament Lengths Column six in Table 5-2 lists the values ofuncracked ligament lengths determined from the UT and EVT examination of the various shroud vertical welds. A comparison of these lengths with those required by the conservative screening criteria lengths (Column 5) shows that each of the vertical welds except V-4, V-9 and V-10 meets the required uncracked ligament length criteria.
A detailed evaluation for welds V-4, V-9 and V-10 is described in the next subsection.
18
(k tt
%'l S
GF NE-BI3-01869-043, Rev.0 5.3 Evaluation ofWelds V-9, V-10, and V-4 The previous section described the evaluation ofthe vertical welds assuming the following:
- 1. Cracks were assumed to be through wall in uninspected regions.
- 2. Both LEFM and limitload failure mechanisms were considered, and the allowable flaw sizes were determined using the ASME Code specified safety factors.
- 3. Abounding crack growth rate of5 x 10 'nches per hour was used in all crack growth analyses.
Appropriate uncertainty factors were used on the crack sizing.
- 5. Evaluation was performed for a period of 16,000 hot operating hours (2 years) and the indications were deemed acceptable ifthe final crack length after crack growth was within the allowable value.
Based on this conservative bounding evaluation, each weld except V-4, V-9 and V-10 was shown to be acceptable for continued operation for at least one fuel cycle (16,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />).
This section describes the detailed evaluation ofthese three welds separately to determine the allowable period of operation.
The first three assumptions were used in this assessment also, but credit for uncracked ligaments was included for part through cracks after accounting for crack growth. The allowable flaw size was determined with the appropriate safety factors and the allowable period of operation was determined. Ofthe three welds, V-9 and V-10 are more limitingand were therefore first evaluated.
5.3.1 Evaluation ofthe V-9 and V-10 Welds Figures 5-3 and 5-4 show the UT determined depths for welds V-9 and V-10, respectively as a function ofdistance from weld H-4. Superimposing the depths ofweld V-10 on V-9 (Figure 5-5 ),
it is seen that weld V-9 is more limiting and is therefore selected for detailed assessment.
Figure 5-6 shows the crack depth profile of V-9 after considering crack growth for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months) and including a UT uncertainty factor of 0.1 inch on depth.
The increment in depth is the crack growth (10,600 x 5 x 10'0.53 in.) plus the UT allowance of 0.1 inch giving a total change of 0.63 inch. As discussed later, the choice of 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> was based 19
k I.
~
I
~ P 44 itic:
=
s ev
GE-NE BI3-01869-043, Rev.0 on the fact that the stress intensity factor corresponding to the cumulative crack depth at 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> was equal to the allowable stress intensity factor of 150 ksiIin.
The projected crack depth after 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> shown in Fig 5-6 is based on bounding crack growth rates as well as conservative cracking assumptions (e.g. assuming all uninspected areas to have through wall cracking) and shows that a part ofthe crack becomes through wall and the remainder ofthe cracking is part through. The part through segment has a depth of 1.35 in. (or a ligament of 0.15 in.) while the main through wall segment has a conservatively estimated length of 32.5 inches.
This crack is idealized as a compound crack as shown in Figure 5-7.
The crack is acceptable if the required safety margins are demonstrated.
Consistent with the A'SME Code Section XI criteria for piping, the safety factor for normal and upset conditions is 3 and the corresponding value for faulted conditions (accident events such as steam line break) is 1.5.
For the V-9 weld axial cracking the primary loading is the internal pressure - 8.9 psi for normal and upset conditions and 22 psi for the steam line break event. After applying the appropriate safety factors, it is <seen that the accident condition is governing.
For the analysis presented here a pressure of22 x 1.5 = 33 psi is used.
Since the safety factor is already included in the pressure, the results can be directly compare'd with the allowables, 150 ksiIin for the stress intensity factor and 3 S for the limit load analysis.
The details of the fracture mechanics and limitload analysis are presented here.
LEFM Anal sis Since there were no standard handbook stress intensity factor solutions available for the compound crack shown in Figure 5-7, a detailed three dimensional finite element model (FEM) with special crack tip elements was developed to determine the stress intensity factors.
Figure 5-8 shows the FEM and Figure 5-9 shows the details of the crack tip elements.
The shroud segment was modeled with three dimensional brick elements and the crack region was modeled with crack tip elements which include the crack tip singularity and directly provide the stress intensity factors.
A 180'egment was modeled and symmetry was assumed to represent the entire shroud.
Sufficiently small mesh size (0.025 in.) was used in the crack region near the intersection ofthe part through and through wall crack segment.
Comparison of the FEM results with and without the axial compression due to the tie rod preload showed that the differences were negligible.
Therefore, the subsequent analysis was based on having no axial load. The ends ofthe model near the H-4 and H-S welds were free so that it simulated a free standing cylinder with no structural benefit from the integrity ofthe horizontal weld. As described before, an internal pressure 20
PP
GE-HE-B13-01869-043, Rev.0 of 33 psi was applied.
The FEM analysis was qualified by comparing the results for simpler cases where handbook stress intensity factor solutions were available.
For a through wall crack without the part through segment, comparison with closed form results showed good agreement confirming that the model was sufliciently refined.
The analysis was performed with different crack depth (for the part through segment) cases and it was determined that for a crack depth of 1.35 inches, the FEM calculated stress intensity factor is approximately 150 ksiIin, which is the irradiated fracture toughness.
This value is based on toughness measurements using specimens made from a plug sample taken from the shroud near the H-4 weld in an operating BWR. The fluence associated with the sample was 8 x 10" n/cm '. This is higher than the estimated peak fluence for the NMP1 shroud, so the evaluation is conservative.
The operating time corresponding to the 1.35 inch depth is 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br />.
Therefore, based on the conservative crack growth rates, and crack sizing, continued operation can be justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> while maintaining the required Code fracture margins.
LimitLoad Anal sis In addition to the fracture analysis, it is necessary to show that adequate limitload margins can be assured for the crack depth of 1.35 in. The results in Table 5-2 show that the required uncracked ligament for the V-9 weld is 3.51 in, or alternatively, the required area is 3.51 x 1.5 = 5.26 in'. For the compound crack shown in Fig 5-7, the available area is approximately 7 in', which is in excess ofthe required value. Thus, the limitload criteria are met.
The evaluation shows that continued operation can be justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months) while still meeting the required margins on fracture toughness as well as limitload.
21
~
~
~
l
GF I4E-BI3-0I869-043, Rev.0 5.3.2 Evaluation ofthe V-4 Weld The crack depths for the V-4 weld are shown in Figure 5-10.
The crack depth after crack growth for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> and including the UT uncertainty allowance of 0.1 inch is also shown in the figure.
Since the V-4 weld is above the top guide support ring, the fluence is sufficiently low so that the material is not embrittled and ductile behavior is assured.
Therefore, fracture assessment is not needed and only limit load evaluation is necessary.
Table 5-2 shows that the required uncracked ligament considering limitload is 1.2S inches, or alternatively, the required uncracked area after crack growth is 1.28 x 1.5 = 1.92 in'. From the crack depth plot shown in Figure 5-10, the available area was calculated to be in excess ofthe required area for the V-4 weld.'herefore, the limitload margins are satisfied for the V-4 weld for a period of 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br />.
5.4 Conclusions Concerning Structural Integrity The structural analysis presented here shows that continued operation can be justified for at least 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br />. In evaluating the structural safety, it is useful to identify the conservatisms used in the analyses:
~
No credit was taken for the horizontal welds; it is assumed that each section ofthe shroud is a free standing cylinder. UT ofthe H-4 and H-5 welds has confirmed that there are significant uncracked areas so that it may be possible to show that even with through wall cracking ofthe V-9 and V-10 welds, structural integrity is maintained.
~
Abounding crack growth rate of5 x 10'nches per hour has been assumed.
The crack growth discussion shows that even after considering potential IASCC contributions, the actual crack growth is expected to be lower than the bounding value used in the analysis.
~
Allowance is made for crack sizing uncertainty for detected flaws,
~
It is assumed that all uninspected regions are cracked through wall,
~
The allowable hours ofoperation assures that the required ASME Code margins are maintained, considering both fracture and limitload mechanisms.
22
La
$4 ~
E A tt'
'W Ih 1
s
'l ~
P
GF NE-BJ3-0I869-043, Rev.0 ftffttttt.
tftftttt lilt a) Infir Figui Figure 5-2 Partial Shell Sectioa 23
~P I 4
t I
'I E
1 f l,
GE-NABJ3-0l869-043, Rev.0 V-9 Flaw Data lO 1.4 1.2 r
1 C
~~
0.8 0.6 CI 0.4 0.2 O
0 10 20 30 40 50 60 70 80 90 Distance from HP in Inches Figure 5-3 V-9 Flaiv Data 24
~M ~
t
GE-NE-BI3-01869-043, Rev.0 V40 Flaw Data a
~~
lO ED c
O 1.4 1.2 1
0.8 0.6 0.4 0.2 0
0 10 20 30 40 50 60 70 80 90 Distance from HP Weld in Inches Figure 5-4 V-10 Flaw Data 25
k rr
GE-ÃE-BI3-01869-043, Rev.O V-9 and V-10 Flaw Data 1.4 c
1.2 1
~~
o.e em 0.6 o.4 O.2 O
0
~ ~
~ ~
10 20 30 40 50 60 70 60 90 V-9
- - - - - -V-10 Distance from HP in Inches Figure 5-5 Comparison ofV-9 and V-10 Flaw Data 26
gh
'I
-1 1
~
4.
GLRIVE-B13-0l869-043, Bev.0 V-9 Initial Depth & Depth after 10,600 Hours 1.4 QO 1.2 V
1 c
~ 0.8 QI) 0.6 O~ 0.4 V
CO V 0.2 I
o 0 '0 20 30 40 50 60 70 Distance from HP in Inches 80 90 Figure 5-6 V-9 Crack Depth after 10,600 Hours 27
I 8
t
GF HF Bl3-OI869-043 Rev.0 H4 Weld 1.35 in.
HS Weld Figure 5-7 Idealized Compouad Crack forV-9 28
0 I
0
GE-NE-B13-01869-043, Rev.0 Figure 5-8 Finite Element Model ofthe Shroud Section 29
e
~,
P
GE-NE BI3-01869 043 Rev 0 Part Through Crack Special Crack Tip Bements Through Wall Crack 1.5 in.
Figure 5-9 Details ofthe Crack Tip Region Showing the Special Crack Tip Elements 30
4 A
GE-NE-B13-0I869-043, Rev.0 V4-Initial Depth & Depth after 10,600 hrs 1.6 1.4 P
r
~
1.2 I
~
c 1
5 O
08 V
0.6 Initial Depth Depth after 10,600 hrs.
~
0.4 0.2 10 15 Distance from H1, in.
20 25 30 Figure 5-10 V-4 InitialDepth and Depth After 10,600 Hours 31
me I I' A
I I
~
L 1 ~
1 4
II
GE-NE-813-01869-043, Rev.0 Table 5-1 Reactor Internal Pressure Differentials Event
'ormal and Upset Faulted H-l to 8-2 B,P S.9 psi 22 psi 8-3 to 8-6a b,P S.9 psi 22 psi Below Core Plate 23.6 psi 63.0 psi Table 5-2 Allowable Flaw Sizes for the Nine MilePoint Unit 1 Shroud Vertical Welds Weld ID V-3, VA (2)
- Length, in 31.25 (3)
Allowable Through wall crack length, in, LEFM LimitLoad 29.97 (4)
Minimum required ligament, in.
1.28 (5)
Min. Ligament including crack growth (two years) and Inspection Uncertainty, in, (Note I) 3.63 (6)
Available Equivalent Uncracked Ligament Length, in.
7.3 (V-3)
Note 2 (VA)
V-7, V-8 V-9, V-10 V-1 1, V-12 V-15, V-16 18.50 90.12 63.50 22.13 18.3 75.40 58.20 17.78 86.61 61.03 19.53 0.72 14.72 5.30 2.46 3.07 17.07 9.30 Note 3 4.81 9.0 (V-7) 5.6 (V-8)
Note 2 (V-9)
Note 2 (V-10) 31.75 (V-11) 25.75 (V-12)
Note 4 (V-15) 5.5 (V-16)
Notes
- 1. Based on crack growth of 1.6 in. and UT inspection uncertainty of2 x 0.375 inch at each crack tip for length sizing.
- 2. Meets requirements based on further evaluation reported in Subsection 5.3.
- 3. The minimum ligament for EVT inspection is larger to account for greater uncertainty in the visual inspection. The uncertainty factor applied is equal to2x1.2in.
- 4. The equivalent length after subtracting crack growth and inspection uncertainty is 2.89 in. which is greater than the required ligament of2.46 in.
and thus acceptable.
32
U I:
'l gt)
W 0
>0 I
GE-NE-BI3-0I869-043, Rev.0 6.0 THERMALHYDRAULICSASSESSMENT An evaluation was performed to assess the potential leakage through shroud vertical weld cracks.
The evaluation included an assessment of the impact of nominal leakage with an assumed through wall crack (actual indications do not have through wall cracks) on normal operation, transients and plant safety.
This evaluation has primarily focused on vertical welds V-9 and V-10.
Leakage from other vertical welds can be bounded by this evaluation because V-9 and V-10 are the longest vertical welds and the calculated crack opening for the postulated through wall flaw is proportional to the weld length.
The results ofthe evaluation are provided below.
6.1 Leakage Estimate The potential crack openings at vertical welds (V-9, V-10, etc. ) were determined from a structural analysis and are dependent on the pressure drop across the shroud wall. It was conservatively assumed that the cracks are throughwall. The leakage flowand impact evaluation was performed at 100% rated power and 100% rated core flow (bounds core flows down to 85%
at rated power) with applicable reactor internal pressure differences (RIPDs) across the shroud wall. The predicted total leakage flowarea for the V-9 and V-10 weld cracks is approximately 3 in'. The loss coefficients for the leakage floware determined to take into account both form and frictional losses.
The predicted leakage flowis summarized in Table 6-1.
Table 6-1 Summary ofLeakage Flows at Rated Conditions Vertical weld cracks, V-9 & 10 Horizontal weld repair (gpm) 200 1510
(% ofcore mass flow) 0.11 0.54 Leakage flow associated with the hardware previously installed to repair the horizontal weld cracks in the shroud (Reference 5) is included in Table 6-1. The leakage flow for the horizontal weld repair takes into account the as built configuration, with leakage at eight holes in the shroud 33
Vt
~ f A
I g4
GE-NE-BI3-0I869-043, Rev.0 head flange, eight holes in the cone, and eight circumferential shroud welds (H H-7). It is conservatively assumed that each of these welds develops a complete circumferential crack that opens to 0.001 inches.
The predicted leakage flow for the vertical weld cracks plus the horizontal weld repair is about 0.65% ofcore mass flow, which is small compared to the core flowuncertainty.
6.2 Detectability A safety assessment of the shroud cracks in the NMP1 plant, prior to the shroud repair, is documented in Reference 7.
Based on that assessment, shroud cracks may be detectable provided that a power anomaly oftwo percent ofrated power results from the expected leakage.
The maximum leakage expected for the shroud condition is less than one percent.
Since approximately a three per cent leakage is required to produce a two per cent power effect, it is concluded that the shroud leakage may not be detectable.
Furthermore, other secondary leakage indicators, such as recirculation loop temperature and core support plate pressure differential, are also too small to be distinguishhble from normal operation measurements.
However, ifthe vertical weld crack develops further creating a larger leakage flowarea, the crack willbe detectable. The threshold for detection of the shroud cracking in the horizontal welds is 1/4 inch (Reference 7), horizontal welds have a much longer length than the vertical welds, V-9 and V-10, by a factor ofapproximately 6. Therefore, a 1/4 inch liftwith the horizontal welds is equivalent to 1.5 inch opening for the V-9 and V-10 welds.
When more than 1.5 inch average opening is created for the entire length of the weld, the power decrease willbe more than 2 %,
and the leakage willbe detectable.
6.3 Impact on Plant Performance and Plant Safety The impact of the leakage flow on the steam separation system performance, cavitation protection, core monitoring, abnormal transients, emergency core cooling system (ECCS) performance and fuel cycle length are evaluated as summarized in the following subsections.
34
~
I ia Pl I
l J
Cl
'P l I W
f' V
GE-I4E-BI3-01869-043 Rev.0 6.3.1 Steam Separation System The leakage flow through holes in the shroud head and weld cracks H-1 and H-2 occurs above the top guide support ring and iricludes steam flow, which slightly increases the total carryunder in the downcomer by about 0.02 weight (wt) % at rated power.
The total leakage flow also has the effect of slightly decreasing the flowper separator and slightly increasing the separator inlet quality.
The separator performance is based on the applicable separator test data over the operating water level range.
The combined effective carryunder from the separators and the shroud leakage remains within the design requirement (0.25 wt %).
The carryover from the separators remains within the design limit so that moisture from the dryer meets'the plant performance requirement ofless than 0.1 wt %.
6.3.2 Cavitation Protection The increased total carryunder due to leakage will decrease the subcooling of the flow in the downcomer slightly. This in turn reduces the margin to cavitation slightly. However, there is no impact compared with the design margin because the total effective carryunder remains within the design requirement.
6.3.3 Core Monitoring The leakage results in an overprediction of core flow by about 0.7% of core flow.
This overprediction is small compared to the core flow measurement uncertainty of 5% for non-jet pump plants (Reference
- 8) used in the MCPR Safety Limit evaluations.
Additionally, the decrease in core flow resulting from the overprediction results in only about 0.2% decrease in calculated MCPR. Therefore, it is concluded that the impact is not significant.
6.3.4 Anticipated Abnormal Transients The code used to evaluate performance under anticipated abnormal transients and calculate fuel thermal margin includes carryunder as one ofthe inputs.
The effect of the increased carryunder due to shroud repair or postulated vertical throughwall cracks results in greater compressibility of the downcomer region and, hence, a reduced maximum vessel pressure.
Since this is a favorable effect, the thermal limits are not impacted.
35
C i
~
~
GE-I4F BI3-0I869-043, Bev.0 6.3.5 Emergency Core Cooling System During LOCA The Design Basis accident is the recirculation discharge line break LOCA for NMP1 plant which relies solely on Core Spray for mitigation of the LOCA events and the subsequent rewetting of the fuel rods (Reference 9).
The effect of the vertical weld cracking on the peak cladding temperature (PCT) during LOCA is determined by whether the core spray flow to the upper plenum region is affected or not.
The leakage through the shroud repair holes or vertical or horizontal shroud cracks does not change the core spray flow or the cooling to the fuel rods or fuel channel.
Therefore, the LOCA analysis results presented in Reference 9, including PCT and metal water reaction, are unchanged by the shroud leakage, and are applicable.
6.3.6 Fuel Cycle Length The combined impact of the reduced core inlet subcooling and the reduced core flow due to the leakage results in a minor effect (<<2 days) on fuel cycle length and is considered acceptable.
6.4 Conclusion The impact ofthe leakage flows through potential vertical weld cracks and the horizontal shroud repair installation have been evaluated.
The results show that at rated power and core flow the predicted leakage is sufficiently small so that the steam separation system performance, cavitation protection, core monitoring, fuel thermal margin and fuel cycle length remain adequate.
Also, no impact on LOCA analysis has been found and the existing LOCA analysis is applicable.
Cracking in the shroud vertical welds V-9 and V-10 may not be detectable during normal operation because the magnitude of the estimated leakage from the postulated through wall cracking is very small. Ifthe crack opens more than 1.5 inches for the V-9 or V-10 weld, the crack willbe detectable.
7.0 OVERALLSAFETY CONCLUSION Extensive examinations were performed to fully characterize all of the shroud vertical welds. A detailed evaluation was performed for all ofthe vertical welds to determine the 36
n i
14
~l
GF 14E-B13-01869-043, Rev.0 structural significance ofthe indications.
Several conservative assumptions were made in the analysis:
~
No credit was taken for horizontal welds; it is assumed that each section ofthe shroud is a &ee standing cylinder.
Thus the presence of horizontal weld cracking has no impact on the vertical weld crack assessment,
~
A bounding crack growth rate of 5 x 10'nches per hour has been assumed.
Field data and predictive models show that this is bounding even with irradiation effects.
Furthermore, because of the excellent water chemistry at NMP1 (reactor water conductivity <0.1 pS/cm), the actual crack growth rates are expected to be much
- lower,
~
All uninspected regions are postulated to be cracked throughwall, and allowance is made for crack sizing uncertainty for detected flaws.
~
The results of the fracture mechanics analysis demonstrate that continued operation can be justified for at least 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months).
The results of the thermal hydraulic evaluation showed that even with postulated through wall cracking of the vertical welds the resulting leakage has no safety impact.
Furthermore, since the vertical weld cracks are within the allowable sizes, they have no impact on the effectiveness of the shroud repair which structurally replaces the horizontal welds.
Based on the evaluation presented, continued operation can be justified for 10,600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> (approximately 16 months).and all ofthe required safety margins willbe maintained.
37
C
GE-NE-Bl3-0I869-043, Rev.0 S. REFERENCES 1.
BWRVIP Document, EPRI TR-105747, "Guidelines for Reinspection ofCore Shrouds (BWRVIP-07)", February 1996.
2.
BWRVIP Document, EPRI TR-105696, "Reactor Pressure Vessel and Internals Examination Guidelines (BWRVIP-03)", October, 1995.
3.
BWRVIP Document, EPRI TR-105873, "Evaluation ofCrack Growth BWR Stainless Steel RPV Internals, (BWRVIP-14)", March 1996.
4.
Gott, Karen, "Using Materials Research Results in New Regulations - The Swedish Approach," Proceedings ofSeventh International Symposium on Environmental Degradation ofMaterials in Nuclear Power Systems - Water Reactors, Volume 1 (pp.
639-649), August 1995.
5.
GE Document GENE-B13-01739-04, "Nine Mile Point Unit 1 Shroud Repair Hardware Stress Analysis", January 1995.
6.
H. Tad, P.C. Paris and G.R. Irwin, "The Stress Analysis ofCracks Handbook", Second Edition (1985).
7.
GE Document GENE-523-A093-0995, "Nine MilePoint 1 and Oyster Creek Shroud Safety Assessment", December 1996.
8.
"General Electric Fuel Bundle Designs", Volume 1, General Electric Company, June 1996 (NEDE-31152P) 9.
D.K. Rao, et al, "Nine MilePoint Unit 1 Loss-of-Coolant Accident Analysis With Two Spargers Available", General Electric Company, September 1993 (NEDC-31446P Supplement 4) 38
A
'l
GE-NE-Bl3-01869-043, Rev.0 Appendix A Effect ofTie Rod Loads on Vertical Weld Stresses
4 I
GF NE-BI3-01869-043, Rev.0 Effect ofTie Rod Loads on V-9 and V-10 Vertical Weld Stresses A-1. Objective The NMP1 shroud modification system consists of four sets of tie rod assemblies between the shroud support cone and the shroud head support ring.
The tie rods are mechanically and thermally pre-loaded with sufficient clamping force to prevent separation of shroud sections at postulated circumferential weld cracks under normal operating pressures.
The analyses described in this note demonstrate that this preload would produce insignificant loads across the V-9 and V-10 vertical welds in the shroud (Figure 1).
A-'2. Analyses Finite element analyses were performed to calculate the stresses from the operating load in each of the tie rods assuming all four tie rods maintain the design preload.
A-2.1 Analysis Model Shroud stresses from the tie rod loads were calculated in finite element analyses using the ANSYS (version 4.4A) computer code.
The 180 'nalysis model shown in Figure 2 was composed of solid elements including rotational degrees of freedom (ANSYS element STIF4).
The solid elements were used to model the shroud head support ring, top guide support ring, core plate
'upport ring, and the stainless steel transition ring.
The shell elements were used to model the cylindrical sections of the shroud and shroud support cone.
Beam elements were used to model the tie rods.
The use ofthe shell elements in the analysis model (instead ofan entire solid elements model) was dictated by the need to limitthe model size.
Except for the top guide support ring, the interfaces between the shell elements and solid elements were modeled by extending the shell elements to cover the surfaces of the solid element rings in order to assure transfer of bending deformations.
A-2
1
GF PIE-Bl3-0I869-043, Rev.0 The surface shell elements in these cases had the same thickness as the shroud thickness and the widths ofthe underlying solid element rings were decreased by corresponding amounts.
The full width ofthe top guide support ring was modeled with solid elements and the shroud sections above and below the ring were assumed to contact the ring at the shroud ID and shroud OD, respectively.
The tie rod at 90'as modeled with the fulltie rod section properties while the rods at 0'nd.1 80'ere modeled with half-section properties as required by the 180 'shroud model.
A-2.2 Boundary Condition The shroud was assumed to be supported at the reactor vessel interface with the shroud support cone. Symmetry conditions were applied at 0'nd 180'.
The tie rod.'loads were simulated as thermal loads by appropriate changes in the tie rod temperatures relative to the shroud temperature.
The temperature difference was selected to produce the normal operation load in the tie rod at 90'nd halfofthe load at the 0'nd 180'n the 180'nalysis model.
A-2.3 Analysis Results The calculated hoop stresses in the entire shroud (for a unit load case with tie rod load equal to 69.5 kips) are shown in Figure 3.
The stress variation in the shell follows the typical pattern of bending stresses in shells attached to a stiff-ring. The tie rod loads produce compressive hoop
'tress in the shell immediately below the top guide support ring. The compressive stress decreases with distance for the top guide support changing into tension which reaches a maximum value and then decreases to a small value along the shroud length.
The maximum tensile stress across V-9 and V-10 is negligibly small.
A-3
GE-NF B13-01869-043, Rev.0 A-3. Summary and Conclusions The operational preload in the tie rods willproduce a negligibly small tensile hoop stress across the V-9 and V-10 vertical welds.
The stresses are insignificant compared to the stresses required for crack initiation and growth ofexisting flaws.
t
~
r, li~
'i
'I IJ "1
'I e
I:e' 0
o
~
~
1A H~
WECHEQERRRRIRKKKW ME&&KÃECRI RRECEKVtRRIESEEKW
~IERailEÃERZ5p&&HW
%EH&
5EQKM=-.=----R QEZRERERZQCIERQA 5150K-;.---- 5 MMR%RMCZKX
+
~
~
~
G I
I I
I&l I I
I
't
'4
'lt 1
II I
I ANSYS 4.4A MAR 31 1997 10:46:46 PREP7 ELEMENTS TYPE NUN YV
-1
+DIST 144.627
+YF 53.25
+ZF 258.521 180-degrees model
(
I+
e-rods NAP shroud: four t$
Figure 2.
Analysis Model (Four tie-rods)
~
~ I
~
~
\\ I
ANSYS 4.4Al NAR 31 1997 ll:06:01 POST 1 STRESS STEP 9999 ITER 1
SY (AVG)
NIDDLf CSYS=1 DNN -0.083549 SNN "6829 SNN =6028 YV DIST~
YF ZF
[/PE pweg "1
144.627 53.25 258.521
-6829
-5400
-3972
-2543
-1115 313.907 1742 3171 4599 6028 hoop stress NNP shroud
- four tie-rods Figurel Iloop Stresses (Four tie-rods)
GE-NE-B13-01869-043, Rev.0 Appendix B Crack Growth Rate Based on the GE Theoretical Model
d
GE.NE.BI3-0J869-043, Rev.0 B-2
I
GF NE-B13-0(869-043, Rev.0 B-3
~
~
GE-NE-BI3-0I869-043, Rev.0
4
't
GE-NF B!3-01869-043, Rev.0 B-5
GE NE-B13-01869-043, Rev.0 B-6
GE-NE-BI3-01869-043, Rev.0 B-7
4 II'
GE-NF B13-01869-043, Rev.0 B-8
GE-NF B13-01869-043, Rev.0 B-9
I
GF NE.Bl3-01869-043, Rev.0 B-10
C 0
GE-HE-BI3-01869-043, Rev.0
(,'I<
GE-ÃE-BI3-01869-043, Rev.0 B-12
A<'
GF HE-BI3-01869-043, Rev.0 B-13
GE-NE-BI3-01869-043, Rev.0 Appendix C Shroud Inspection Summary
E.
T I
4l 1IL l
t
GE-HE-BI3-01869-043, Rev.0 The following is a weld by weld summary detailing the scope of inspections and results of the shroud examinations performed to date.
Weld V-3 Performed ultrasonic examination of approximately 15 inches of each side of the weld from the shroud OD surface.
Approximately 1.5" of flaw was detected on the ID surface and 0.8" offlaw on the OD surface.
Weld V-4 Performed ultrasonic examination ofapproximately 11" ofthe left HAZand 22" ofthe right HAZ.
ID flaws were detected over the entire examined length of the left HAZ and 1.5" of flaw was detected on the ID ofthe right HAZ.
Weld V-7 Performed ultrasonic examination ofapproximately 9" ofthe left HAZ and 11" ofthe right HAZ.
No flaws were detected during the examination.
Weld V-S Performed ultrasonic examination of approximately 5.5" of the left HAZ and 9.5" of the right HAZ.No flaws were detected during the examination.
Weld V-9 Performed ultrasonic examination from the shroud OD surface for approximately the entire length ofboth the left and right HAZs as well as EVT from both the ID and the OD. Visual cracking was detected over greater than 90% ofthe right HAZon the OD and minimal cracking was detected on the ID in both the left an right HAZs. Minorcracking was also detected on the OD in the left HAZ.
The cracks detected visually on the shroud ID surface were found to be predominantly transverse
'o the weld whereas the cracking detected visually on the shroud OD surface was mostly parallel to the weld with components that branched transverse to the'weld. Ultrasonic examinations of essentially the entire length of the weld was performed from the shroud OD surface and detected numerous flaws over the length of the left HAZ emanating from the shroud OD surface.
Two small flaws on the ID surface were detected in the right HAZ.
Weld V-10 Performed ultrasonic examination from the shroud OD surface for approximately the entire length ofboth the left and right HAZs as well as EVT from both the ID and the OD. Flaws were detected on greater than 80% of the right HAZ on the OD surface and greater than 50% of the left HAZ revealed flaws on the OD surface.
The EVT examination revealed cracking in the left and right C-2
Oa-I
~
'l I
0 l
acr I
t
GE-NE-BI3-0I869-043, Rev.0 HAZs on the OD surface for most ofthe length ofthe weld and on the ID in both the left and right HAZs. The cracks detected visually on the shroud ID surface were found to be predominantly transverse to the weld whereas the cracking detected visually on the shroud OD surface was mostly parallel to the weld with components that branched transverse to the weld.
Weld V-11 EVT examinations were performed on the accessible weld length from both the ID and the OD of both the left and right HAZs. No cracking was detected during.the examination.
Weld V-12 EVT examinations were performed on the accessible weld length &om both the ID and the OD of both the left and right HAZs. One 6" crack was detected on the length OD surface in the right HAZ. No other cracking was detected.
Weld V-15 Ultrasonic examination was performed from the shroud OD surface on approximately 11 inches of both the left and right HAZs.
One 6" flaw was detected in the left HAZ on the ID surface and several ID flaws totaling 2.2" in total length was detected on the ID in the right HAZ. No flaw detected in either HAZwas greater than 10% through wall.
Weld V-16 Ultrasonic examination was performed from the shroud OD surface ofapproximately 10.5" ofleft HAZ. Two flaws were detected on the ID surface. One flaw was 5" in length, 10% through wall.
The other ID flaw in the left HAZ was detected &om the scan on the right HAZ and was 3" long and 30% through wall. Approximately 22 inches of the right HAZ was examine from the shroud OD surface.
One flaw was detected on the ID which measured 4" in length and 21% through wall.
An EVT examination of both HAZs from the shroud OD surface revealed one crack in the left HAZ.
Recent Inspection Results for Shroud Horizontal Welds In addition to the shroud vertical weld inspections, the horizontal welds H-2, H-4, H-5, H-6a, H-6b, and H-7 were also inspected for analytical purposes, to evaluate the overall integrity of the shroud using assumptions of worst case cracking of the vertical welds.
C-3
T v
CC 4
'I 4
J m
GE-HE-B13-0I869-043, Rev.0 Weld H-2 Ultrasonic examination was performed from the shroud OD surface of approximately 24 inches of the upper HAZ adjacent to weld V-4.
Approximately 7 inches of intermittent flaws were detected on the OD surface, with the deepest area having a through wall depth of.22 inches.
Weld H-4 Ultrasonic examination from the shroud OD surface was performed on approximately 60% ofthe lower HAZ. ID and/or OD flaws were detected intermittently throughout the examination area.
Some ID flaws were detected in the upper HAZ. Approximately 32 inches ofthe upper HAZwas ultrasonically examined.
3 inches ofshallow OD flaws were detected in the upper HAZand one 6 inch long ID flaw was detected with the maximum through wall depth of.23 inches..
An EVT examination of the OD was performed of over 70% of the upper and lower HAZs. Cracks were detected in both the upper and lower HAZs.
Weld H-5 Ultrasonic examination from the shroud OD surface was performed on approximately 30% of the upper and lower HAZs. OD and ID flaws were detected in the upper HAZ only. No flaws were detected in the lower HAZ. EVTofapproximately 60% ofthe shroud OD surface revealed cracks intermittently in both the upper and lower HAZs. Most of the flaws detected visually on the OD surface were oriented perpendicular to the weld.
No flaws were detected in the upper HAZ at the intersections ofwelds V9 or V10.
Weld H-6A Ultrasonic examination was performed on both the upper and lower HAZs of approximately 30%
of the circumference from the shroud OD surface.
Flaws were detected on the OD surface of the lower HAZonly. No flaws were detected in the upper HAZor on the IDofeither HAZ.
Weld H-6B Ultrasonic examination was performed on both the upper and lower HAZs of approximately 30%
of the circumference from the shroud OD surface.
Flaws were detected on the OD'surface of the upper HAZonly. No flaws were detected in the lower HAZor on the IDofeither HAZ.
Weld H-7 Ultrasonic examination was performed for the shroud OD surface on the upper HAZ on approximately 30% ofthe circumference.
No flaws were detected during the examination.
Weld H-8 Ultrasonic examination was performed for the shroud OD surface on the lower HAZ on approximately 30% of the circumference.
A flaw which was identified by UT during a prior
g E, V
L 4
lk l
GE NE-BI3-01869-043, Rev.0 outage was located as well as one additional flaw in the same area.
This flaw was ultrasonically sized to be of lesser through wall depth than in RFO13. A review of the previous data indicates that the previous sizing performed was very conservative.
An EVT was performed on approximately 30% of the circumference from the shroud OD surface.
Of the five small cracks visually detected during RFO13 only 1 was visible during this inspection.
The inspection in the area of the other four was hampered by the placement of a Tie Rod support which prevented a
good EVT inspection. Cracks were visually detected in three new locations in the upper HAZ. The largest ofthese cracks (9"-12") is located predominantly in the ring segment Upper HAZand runs into the weld toe and back into the ring segment.
Weld H-9 An EVT examination was performed in one area 26 inches long. No indications were noted during the examination.
C-5
I ~n aa
~ ~ ~ ~
,e na, aa++
~
NINE NILE POINT 1 SHROUD RF814 VISUAL INSPECTION RESULTS Jap".
~a ICa 20 20'0 50a Ce 20'0a
'50 100a II0 I20'I0 I<0 l50 ICCa IIC I00'W 200'IC'20a 250a 2cta 250'0a 2I0'0'0 500'IC'20a 250 5I0 250t'00'l H2 H3 H4 V3 Vl Vb V6 VB V2 Hl H4 H3 IL5b VIB
'lb.I2 H5
~ 0$
H5 VII VI2 HSA HSB H7 HS V!3 V15 VI4 VI6 HBA HBB H8~ '
.58 22.I5 H7
.. L SHROUD SURFACE DEVELOPMENT SHROUD SECTION VIEW
0
NINE MILE POINT 1 SHROUD RFOI4 INSPECTION RESULTS
~~
N tr tr
%~ 5I er tr tr 'Ir Iw IIr Itr Ix IN le Icl IIr ltr Nc ttr tlr ttr ttr tIr tsr ttr ttr ltr~ ttr tII tto~ Mr tIr ttr ttr Jop4 Hl H2 H3 H4 V3-VI V4 V6 ve V2 Hl H2
'4 Vle H5 H5.
VII VI2 L
H6A H6B "
H7 HB VI5 SHROUD SURFACE OEVELOPMENT VI6 H6A H6B HB~.,~H7 J
SHROUO SECTION VIEW
V9 V10 H4 ID View Only V9 L V10 Examined On the ID.
H5
~
4 IO'0 30'0>>
30>>
60o 70 ~
80 ~
00
~
IOO IIO l20'30>>
IgO I30'60 l70>>
I80'OO 800'IO>>
880 ~ 8
~ 840 830 860 ~
870 880 890>>
300 3 0 ~ 380 330 3>>0 ~ 330 ~ 360 ~
H4 OD View 105 deg to 140 deg 145 deg to 170 deg 355 deg to 360 deg Not xGain d
H5 V9 V10 Note-Crack lengths and posltlons and weld widths are nol to scale.
Crack posllions are as viewed towards reactor vessel center.
/ I GE Nuclear Energy Nagara hfohawk Power Ccupara5on Nne hNe Poht-Unft1
'ltrasonicExamination Indication Map Eor Core Shroud Weld V3 Ptl Mfeld H l 10"--
Region Examined 8.35" to 23.6" 23%T lD
)1.5" L 8%T OD Region Examined 6.50" to 17.8" 20"--
30+N MfeldH2 Core Shraad &amhatfon Project-10frr
I I SE Nuclear Enemy Nayua hfohewfc Power Cepo~5on NnehNeNnt-Unit1
'ltrasonicExamination Indication Map For Core Shroud Weld V4 Weld H1 20" 4%T Avceage tD 1.5" L
(
53%7 1.5' Region Examined 6.35" to 17.6" Region Examined 8.35 to31.0'ELD V4 Weld H2
/ I GE Nuclear &eq~
INa~ua hfohewk Power Capone)
Nne hNe Point-Unitf Ultrasonic Examination indication Map For Core Shroud Nfeld V7 P
sg w
Weld H3 5"
No Flaws Detected 10>>
Region Examined 2.3" to 11.3" 5" -
Region Examined 0.74" to 12.0" pr Weld H4 Cae Shned Exemfre5on Praject - 1QH
0 U
4
1 GE Nuclear Energy llama Mohewk Power Capara5an She hSe Poht-Unit 1 Ultrasonic lamination Indication Map Eor Core Shroud Mfeld V8 Weld H3 5tl
't No Flaws Detecfecf
)Clnn en Region Examined 0.56" to 6.
0'N Region Examined 0.56" to 10.0n Weld H4 Cose Shroed Brenahetfen~- NOT
/ I GE Nuclear Energy Hlagara Mohawk Power Cwporatfon Hln MllePofnt-Unit 1 Ultrasonic Examination indication Map For Core Shroud Weld V9
~aR~J 55UlRhiX
(
SOLD H4 B~
RRLII~>
I NELDH5 Core Shroud &amlnatlon Plogct-1%V'
GE Hue!ear Enen~
INegsla Nohewk Power CNpora5on INne hNe Poiht-UnIt 1 Ultrasonic Examination Indication Map For Core Shroud VYeld V10 NKDH4 Rw.Oops 225Z Rw.Oeph Rw.DepO 2$%T ANRawe le/@sent ag~ggag et5hruud OD lfBUl@5Z S4eCece 2RLI i RwOepO
)
2S%T Rw~
25%T Cons Shnmd &anaoetfon Rajrct-fOOT
OE IIIuclearEnergy Nlepenj Mohewk Power Caponrtion Nine MilePoint-Unit 1 Ultrasonic Examination Indication Map For Core Shroud lVeld V15 6.3" L ID 58oT 1.5" L ID 5okT 0"
Weld H6B 5'egion Examined 0" to 11;2" 0.7" L ID 3'YoT Region Examined 4.6" to 15.6" 15" 20" 1Veld H7 Cote Shroud Exemlnetion eject - 1997
0
/ I GE Huc(ear Energy Nagara MohrrwlrPower Cepora5on Nine Nh Paint - tjrrlt 1 Ultrasonic Examination Indicefon Map For Core Shroud Mfeld V16 Mfeld86B.
5.0" 10%T 4.0 L 21%T lD Reghn Examhed 0 to 10.5 Ron Examtned 1.0 to 15.3" MfELDV16 3.0" L 30% T tD Regton
'.Exlmtned 16M to 22" Weld H7 Core Slrreud Exarrrhetbrr Reject - 1997
/ I GE Nuclear Enenry Niagara Mohewk Power Corporetlon Nine MllePoint-Unlt1 Ultrasonic Examination Indication Map For Core Shroud Weld H2 Note: Scanned Fsum Top Side ofMfeldOnly 270 Core Slrrorrd Erurrlnetlon Proiect-1097
/ I GE Nucleer Eneqly hthgare Nohawlr Power Corpora5on Nne lNoAnt-Unit0 Ultrasonic Examinatron lndicatIon Map For Core Shroud Nfeld H4 Note: Scanned Fnun Bottom Side ofMfeld Only
/
29%
Aveage 10%T 10%T Exam fhgian (1) 10%T/ /
27%
10%T 13%
Exam Ragke g)
Notes 3R%
(1) Scanned Fram Top Sde (2) Scanned Fram Bottom Sde 1NT
/ I GE Nuclear Energy ICegate Mohawk Power Co poretln hNe hNe Paht - Uhtt 1 Ultrasonic Examinafon Indication Map For Core Shroud Weld H5 Note: Scanned Fmm Both Top and Bottom Sides of Mfeld sam 180 IIV'6Hew Nap
0
i I GE Nuclear Energy Hiegera Mohawk Power Guporatton NEne MllePoint-tjnlt1 Ultrasonic Examination fncfication Nap For Cote Shroud Weld HSA Note: Scanned Fram Bottr Top and Bottom Sdes ofWeld Note: ANRees Origirate On Forged Ringgo~ Sde OfWeld.
30% TAverage T Madmxn 40%T TAverage 46% T Qadmum 0
ram R~o 4NiT 30%T 40%T 15%T 29%T 4% TAverage 53% T Medmum 29%T 47% T 50% T NelcfHSA Flaw Nap
GF. NuClear Energy Hlagara Mohawk Power Capora5on Hlne MllePoint-Unit 1 Ultrasonic Examination Indicatfon Nap For Core Shroud MfeldH6B Note: Scat+ed Rum Both Top and Bottom Sides ofWeld Note: ANRews Originate On Forged Ring (Uppers Side OfWeld.
Exam Reghn Exam Reghn 25% T
-25%T 26%T R~,
-25%T 180 Weld H6B Flaw Nap Cori &rnxtct&amlna8on Pmject-NQ7
/ I GE Nuclear Enetiy Hlegare Nohewk Power Co~oretton Nine NilePoint-Unit 1 Ultrasonic Examination indication Map For Core Shroud MfeldH7 Note: Scanned Fram Top Side ofMfeldOnly No Flaws Detected
'f80 Core Shnwd &anlnetlon Project-1097
/ I GE Nuclear Energy Niagara Nohawk Power Ccupontlon NlrbMllePoint-Unit 1 Ultrasonic Examinatron Indication Map For Core Shroud VVeldHS Shroud Cone SMr 129 in. L 10% T Botfnm Skfe ofWeld R2tn L 13% T Bottnm SHe ofVWd Weld H8 Raw Nap Cae Shroud Eraminatfon PmJect-1097