Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20205L054 | 1 April 1999 | Nonproprietary Replacement Pages to HI-91738,consisting of Section 5.0, Thermal-Hydraulic Analysis | Finite Element Analysis Fuel cladding |
ML17059C550 | 31 January 1999 | Rev 0 to MPR-1966(NP), NMP Unit 1 Core Shroud Vertical Weld Repair Design Rept. | Operating Basis Earthquake Design basis earthquake Foreign Material Exclusion Liquid penetrant Flow Induced Vibration |
ML20151P175 | 16 June 1998 | Rev 0 to SIR-98-067, Evaluation of NMP Unit 2 Feedwater Nozzle-to-Safe End Weld Butter Indication (Weld 2RPV-KB20, N4D) | |
ML20198B499 | 15 May 1998 | Non-proprietary Replacement Pages for Attachment F to Which Proposed to Change TS 5.5, Storage of Unirradiated & Sf | Fuel cladding |
ML17059C168 | 19 March 1998 | Revised Niagara Mohawk Powerchoice Settlement Document for NMPC PSC Case Numbers 94-E-0098 & 94-E-0099, Vols 1 & 2 | Incorporated by reference Earthquake |
ML18040A330 | 28 February 1998 | Rev 0 to Technical Rept 97181-TR-03, EPR Testing of Boat Samples from Core Shroud Vertical Welds V-9 & V-10 at NMP Unit 1. | |
ML17059B905 | 28 February 1998 | NMP Unit 1 Boat Samples Analyses Part Iii:Tension Tests, RDD:98:55863-004-000:01 | |
ML17059B906 | 28 February 1998 | Non-proprietary Rev 0 to GE-NE-523-B13-01869-113NP, Assessment of Crack Growth Rates Applicable to NMP Unit 1 Vertical Weld Indications. | |
ML17059B907 | 28 February 1998 | Rev 0 to Technical Rept 97181-TR-02,Vol 1 to Interpretive Metallurgical Rept on Core Shroud Vertical Weld Boat Samples from NMP Unit 1. | |
ML20217F120 | 30 September 1997 | Rev 1 to Boat Sample Analyses at NMP Unit 1 | |
ML17059B677 | 11 August 1997 | Rev 0 to Evaluation of Overlay for RWCU Weld 33-FW-22. | Safe Shutdown Earthquake Weld Overlay FLEX |
ML17059B590 | 30 June 1997 | Rev 0 to Metallurgical Evaluation of Failed Shroud Tie Rod Lower Spring Contact Wedge Latches, for June 1997 | |
ML17059B486 | 30 April 1997 | Non-proprietary Rev 0 to GE-NE-523-B13-01869-043, Assessment of Vertical Weld Cracking on NMP1 Shroud. | Finite Element Analysis EVT-1 |
ML17059B488 | 30 April 1997 | Non-proprietary Rev 0 to Gene B13-01739-40, Shroud Repair Anomalies NMP1,RF014. | Safe Shutdown Flow Induced Vibration |
ML17059B511 | 30 April 1997 | Non-proprietary Version of Rev 1 to GE-NE-523-B13-01869-043, Assessment of Vertical Weld Cracking on NMP1 Shroud. | Finite Element Analysis EVT-1 |
ML17059B489 | 30 April 1997 | Non-proprietary Rev 0 to Gene B13-01739-22, Design Rept for Improved Shroud Repair Lower Support Latches. | Finite Element Analysis |
ML17059B507 | 30 April 1997 | Final Rept, Analysis of Nine Mile Point Unit 1 Shroud Weld V9 & Weld V10 Cracking. | Non-Destructive Examination Finite Element Analysis |
ML17059B493 | 3 April 1997 | Core Shroud Cracking Evaluation. | |
ML17059B241 | 13 August 1996 | NMP-1 Core Shroud Repair Mod Summary Rept. | |
ML17059B244 | 13 August 1996 | Non Proprietary Version of Suppl 1 NMP-1 Seismic Analysis, Core Shroud Repair Mod. | |
ML17059B242 | 13 August 1996 | Suppl 4 NMP-1 Shroud Repair Hardware Stress Analysis. | |
ML17059B243 | 9 August 1996 | Rev 4 to Stabilizer Installation. | Safe Shutdown Anticipated operational occurrence Foreign Material Exclusion Flow Induced Vibration |
ML18040A180 | 1 August 1996 | Rev 5 to Reactor. Drawings Encl | |
ML17059B122 | 29 April 1996 | Nonproprietary Core Shroud Repair 270 Degree Tie Rod Assembly Assessment. | Safe Shutdown Coatings Finite Element Analysis Design basis earthquake Flow Induced Vibration |
ML17059B009 | 29 November 1995 | NMP Unit 2 Safety Evaluation Summary Rept. | Safe Shutdown Half scram Grab sample Fire Barrier Stroke time Water Inventory Control Probabilistic Risk Assessment Temporary Modification Scram Discharge Volume Excess Flow Check Valve Battery sizing Control of Heavy Loads Turbine Missile Fire Protection Program Fire Watch Power Uprate |
ML18040A167 | 29 September 1995 | NMP Nine Mile Point Unit 1 Nuclear Power Station Rept of RPV FW & CRD Return Line Nozzle Exams Performed for NUREG-0619...at Culmination of Refueling Outage 13 Which Ended on 950404. | Nondestructive Examination |
ML17059B018 | 20 January 1995 | Feedwater Nozzle Analysis. | |
ML18040A162 | 16 January 1995 | Rev 2 to 25A5583, Shroud Repair Hardware. | Earthquake Liquid penetrant |
ML17059A578 | 31 December 1994 | Non-proprietary Version of Final Rept Plant-Specific Charpy Shift Model for Nine Mile Point Unit 1. | |
ML17059A504 | 31 December 1994 | Unit 2 Safety Evaluation Summary Rept 1994. | Safe Shutdown Fitness for Duty Shutdown Margin Stroke time Hydrostatic Temporary Modification Spiral reload Control of Heavy Loads Fire Protection Program Power change |
ML18040A297 | 31 October 1994 | Final Rept Entitled Fracture Mechanics Assessment of Nine Mile Point Unit 1 Shroud H4 Weld. | Finite Element Analysis Power change |
ML18040A227 | 19 August 1994 | Nuclear Engineering Rept, Nine Mile Point Unit 1 Shroud Cracking Safety Assessment for GL 94-03. | Safe Shutdown Earthquake Probabilistic Risk Assessment Earthquake |
ML17059A361 | 6 July 1994 | Emergency Action Level Verification & Validation Rept. | Earthquake |
ML17059A353 | 10 June 1994 | Ny State EAL Upgrade Project Nine Mile Point Unit 1 EAL Generation Package. | Safe Shutdown High winds Reactor Vessel Water Level Ultimate heat sink Offsite Dose Calculation Manual Safeguards Contingency Plan Earthquake Fuel cladding Pressure Boundary Leakage Power change Unidentified leakage |
ML17059A355 | 10 June 1994 | Eals. | Safe Shutdown Health Physics Network Reactor Vessel Water Level Ultimate heat sink Offsite Dose Calculation Manual Hydrostatic Operating Basis Earthquake Safeguards Contingency Plan Battery sizing Earthquake Fuel cladding Pressure Boundary Leakage Power change |
ML17311A018 | 13 May 1994 | New York State EAL Upgrade Project Verification & Validation Rept. | Safe Shutdown Shutdown Margin Reactor Vessel Water Level Ultimate heat sink Offsite Dose Calculation Manual Safeguards Contingency Plan Battery sizing Earthquake Fuel cladding Pressure Boundary Leakage Offsite Circuit Power change Unidentified leakage |
ML17059A340 | 30 April 1994 | Rev 0 to Nine Mile Point Unit 1 Feedwater Nozzle Fatigue Evaluation. | Finite Element Analysis Exemption Request Liquid penetrant |
ML17059A341 | 30 April 1994 | Rev 0 to Nine Mile Point Unit 1 CRD Return Nozzle Fatigue Evaluation. | Hydrostatic Finite Element Analysis Exemption Request |
ML17059A088 | 31 December 1993 | Safety Evaluation Summary Rept 1993. | Safe Shutdown High Radiation Area Grab sample Temporary Modification Process Control Program Excess Flow Check Valve Exemption Request Control of Heavy Loads Fire Protection Program Fire Watch |
ML17059A031 | 31 August 1993 | Elastic Plastic Fracture Mechanics Assessment...Nine Mile Point,Unit 1:Response to NRC RAI Re GL 92-01 | Finite Element Analysis |
ML18038A738 | 17 March 1993 | Upper Shelf Energy Uncertainty Analysis for Nine Mile Point Unit 1 Beltline Welds Final Rept | |
ML18038A735 | 22 February 1993 | Final Rept, Elastic-Plastic Fracture Mechanics Assessment of Nine Mile Point Unit 1 Beltline Plates for Service Level C & D Loadings. | Finite Element Analysis |
ML18038A736 | 19 February 1993 | Beltline Plate Orientation Determination, Final Rept | |
ML18037A083 | 16 December 1992 | Elastic-Plastic Fracture Mechanics Assessment of Nine Mile Point Unit 1 Beltline Plates for Svc Level a & B Loadings. | |
ML18038A726 | 19 November 1992 | Technical Response to SE by NRR Related to Proposed Deferment of Torus Mods, Nmp,Nmpns,Unit 1 Docket 50-220 | |
ML17056C109 | 29 October 1992 | NMP Unit 2 Safety Evaluation Summary Rept. | Safe Shutdown Shutdown Margin Reactor Vessel Water Level High Radiation Area Grab sample Temporary Modification Zebra Mussel Turbine Missile Biofouling Fire Watch |
ML18038A714 | 16 October 1992 | Final Rept Entitled, Elastic-Plastic Fracture Mechanics Assessment of Nine Mile Point Unit 1 Beltline Plates for Service Level a & B Loadings. | |
ML18038A518 | 12 June 1992 | Response to GL 92-01 for Nine Mile Point Unit 1. | |
ML17056B478 | 31 December 1991 | Unit 2 Safety Evaluation Rept 1991. | Safe Shutdown Temporary Modification |
ML18038A374 | 9 September 1991 | Rev 1 to Root Cause Rept for Exide UPS 1A,B,C,D & G Trip Event of 910813. Electrical Fault on B Phase Main step-up Transformer Occurred Due to Improper Design.Logic Power Supply for Subj UPS Units to Be Modified | Reserve Station Service Transformer |