UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 M:m:h 21 I 2016 LICENSEE:

Tennessee Valley Authority FACILITY:

Watts Bar Nuclear Plant, Unit 1

SUBJECT:

SUMMARY

OF FEBRUARY 5, 2016, PUBLIC MEETING WITH TENNESSEE VALLEY AUTHORITY REGARDING WATTS BAR NUCLEAR PLANT, UNIT 1, LICENSE AMENDMENT REQUEST TO INCREASE TRITIUM PRODUCTION (CAC NO. MF6050)

On February 5, 2016, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Tennessee Valley Authority (TVA) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss a license amendment request (LAR) to increase the maximum number of tritium-producing burnable absorber rods (TPBARs) permitted to be loaded into the reactor core at the Watts Bar Nuclear Plant (WBN), Unit 1. The meeting notice and agenda, dated January 7, 2016, are available in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML16021A349. Representatives from the Department of Energy also attended the meeting. A list of attendees is enclosed.

The March 31, 2015 LAR (ADAMS Accession No. ML15098A446), proposed to increase the number of TPBARs allowed to be loaded from 704 to 1,792. TVA supplemented its March 2015 submittal with letters dated May 27, 2015, and June 15, 2015 (ADAMS Accession Nos. ML15147A611 and ML15167A359, respectively). The NRC staff identified several outstanding technical issues in TVA's response dated December 22, 2015 (ADAMS Accession No. ML16054A661 ), to the staff's request for additional information issued on October 2, 2015 (ADAMS Accession No. ML15278A048). The outstanding issues related to demonstrating the adequacy of TVA's tritium control and monitoring to ensure onsite exposures will not result in occupational doses above Title 10 of the Code of Federal Regulations Part 20 limits, and demonstrating that effluent releases under the proposed design-basis assumptions will not exceed the dose limit to a member of the public. These issues were communicated to TVA by e-mail dated January 14, 2016 (ADAMS Accession No. ML16053A023).

TVA's presentation (ADAMS Accession No. ML16063A025) included a brief summary of the tritium production program background and previous amendments related to tritium production at WBN, Unit 1. The presentation also addressed operating experience, monitoring programs, the proposed tritium source term in the current amendment request, and liquid waste management.

TVA's presentation included information regarding its plans to supplement the submittal. TVA stated that the tritium control and monitoring program and the proposed design-basis source term would be revised to address the staff's outstanding issues. In response to a question from the staff, TVA indicated that the proposed source term for the evaluation of accidents in the current submittal would not be changed.

TVA indicated it was in the process of evaluating its schedule for providing the supplement and would give the anticipated date for providing the supplement when this evaluation has been completed. Subsequent to the meeting, TVA informed the staff that it would provide the supplement no later than March 31, 2016.

Members of the public were not in attendance and no Public Meeting Feedback forms were received.

Please direct any inquiries to me at (301) 415-1349 or Jeanne.Dion@nrc.gov.

Docket No. 50-390

Enclosure:

List of Attendees cc w/enclosure: Distribution via Listserv

/f)

(',-C'v*--- ~

anne A. Dion, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

LIST OF ATTENDEES Licensee:

Subject:

Tennessee Valley Authority (TVA)

License Amendment to Increase Tritium Production Plant: Watts Bar Nuclear Plant, Unit 1 Date:

February 5, 2016 Location:

U.S. Nuclear Regulatory Commission Time: 9:00 a.m. -10:30 a.m.

(NRC) Headquarters, One White Flint North, Room 07-804 NAME TITLE ORGANIZATION NRC/Office of Nuclear Reactor Paul Krohn Acting Deputy Director Regulation (NRR)/Division of Operating Reactor Licensing (DORL)

Alex Klein Acting Deputy Director NRC/NRR/Division of Risk Assessment (ORA)

Ben Beasley Branch Chief NRC/NRR/DORL/Plant Licensing Branch 11-2 (LPL2-2)

Undine Shoop Branch Chief NRC/NRR/DRA/Radiation Protection and Consequence Branch (ARCS)

Robert Schaaf Project Manager NRC/NRR/DORL/LPL2-2 Jeanne Dion Project Manager NRC/NRR/DORL/Plant Licensing Branch 111-2 NRC/NRR/Division of License William Rautzen Health Physicist Renewal/Environmental Review and Project Management Branch Roger Pedersen Senior Health Physicist NRC/NRR/DRA/ARCB Enclosure NAME TITLE ORGANIZATION Erin Henderson Senior Manager, Fleet Tennessee Valley Authority (TVA)

Regulatory Operations Carla Borrelli Senior Program Manager TVA Tritium Production David Brown General Manager, Reactor TVA Engineering and Fuels Doug Pollock Safety Analysis Project TVA Manager Clint Szabo*

TVA Ed Schrull*

TVA Bill Sitten*

TVA Nanette Founds*

Department of Energy (DOE)

Curtis Chambellan*

DOE Thomas Hiltz*

DOE James Smith*

Westinghouse

  • participated via teleconference term would be revised to address the staff's outstanding issues. In response to a question from the staff, TVA indicated that the proposed source term for the evaluation of accidents in the current submittal would not be changed.

TVA indicated it was in the process of evaluating its schedule for providing the supplement and would give the anticipated date for providing the supplement when this evaluation has been completed. Subsequent to the meeting, TVA informed the staff that it would provide the supplement no later than March 31, 2016.

Members of the public were not in attendance and no Public Meeting Feedback forms were received.

Please direct any inquiries to me at (301) 415-1349 or Jeanne.Dion@nrc.gov.

Docket No. 50-390

Enclosure:

List of Attendees IRA!

Jeanne A. Dion, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation cc w/enclosure: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL2-2 R/F RidsNrrPMWattsBar Resource RidsNrrDlrRerb Resource RidsNrrDraArcb Resource RidsOpaMail Resource RidsNrrDorl Resource WRautzen, NRR TWertz, NRR KBucholtz, NRR RPedersen, NRR Watts Bar Resident Inspector RidsNrrLABClayton Resource TClark, OEDO RidsNrrDorllpl2-2 Resource RidsRgn2MailCenter Resource RidsACRS_MailCTR Resource ADAMS A ccess1on N o.: ML16063A036 Pk ML16063A025

g
  • 1 ema1 concurrence OFFICE NRR/DORL/LPLI 11-2/PM NRR/DORL/LPLll-2/LA NRR/DRNARCB/BC NAME JDion (LRonewicz for) BClayton UShoop*

DATE 3/14/2016 3/07/2016 3/14/2016 OFFICE NRR/DLR/RERB/BC NRR/DORL/LPLll-2/BC N RR/DORL/LP LI 11-2/PM NAME JDanna*

BBeasley JDion DATE 3/17/2016 3/17/2016 3/21/2016 OFFICIAL RECORD COPY