DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CON2, 612, 70 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-241

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 07 - CON2, 612, 70

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments OjwAMAjdUEU-&

Evaluated by:

Lindsay M. Yates Date:

08/15/2013 4"4-Neda Stoeva 08/15/2013 D-242

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [-] N U Area Walk-By Checklist (AWC)

Location (Bida, Elev, Room/Area):

Area 07 - CON2, 612, 70 P9120065 P9120066 D-243

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC) 07-D-244

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y] N U Area Walk-By Checklist (AWC)

IluZUU/ (

D-245

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y] N U Area Walk-By Checklist (AWC) 07 - C D-246

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: LI-I N U Area Walk-By Checklist (AWC)

Area 07 -

D-247

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC) 07-D-248

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y] N U Area Walk-By Checklist (AWC)

Area 07 -

D-249

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: *-] N U Area Walk-By Checklist (AWC) a D-250

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y [iN U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 08 - AB2, 609, 140 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Equipment anchorage is internal, could not see

2.

Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Not Applicable Not Applicable

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Yes

4.

Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes

5.

Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Fire protection piping - C02 system. Rod hung.

6.

Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Yes Yes

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes D-251

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y FN-I U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 08 - AB2, 609, 140 Hook with magnet on side of SG - will not be a seismic hazard due to strength of magnet

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments George G Thomas Evaluated by:

Date:

08/15/2013 Samantha Justice per teleconference withSamantha Justice on 8/7/2013 08/15/2013 D-252

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y [I] U Area Walk-By Checklist (AWC)

Location (Bida. Elev. Room/Area):

Area 08 - AB2. 609. 140 P9120172 P9120173 D-253

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y [N U

Area Walk-By Checklist (AWC) 08-D-254

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y EN-U Area Walk-By Checklist (AWC) 08.

D-255

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y

] U Area Walk-By Checklist (AWC)

Area 08 D-256

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y *j U

Area Walk-By Checklist (AWC)

Area 08 - AB2, 609, 140 D-257

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - AB2, 621, 10 - BY 2MRV-243 & 2-FFI-240 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?

D-258

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

YI-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - AB2, 621, 10 - BY 2MRV-243 & 2-FFI-240 Ladder OK laid flat underneath pipes away from equipment

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

-....George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-259

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: EY N U Area Walk-By Checklist (AWC) ea 10-D-260

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F N U Area Walk-By Checklist (AWC)

Location Bid, Elev, Room/Area :

Are a 10 - AB2. 621. 10 - BY 2MRV-243 & 2-FFI-240 D-261

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 10 - AB2, 621, 10 - BY 2MRV-243 & 2-FFI-240 D-262

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - AB2, 612, 12 - BY 2-NPS-111 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-263

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [i* N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - AB2, 612, 12 - BY 2-NPS-111 Ramp piece not tied to anything by 2-ECR pressurized gas bottles infront of ramp, but ramp leans up against the bottle supports as found. Judged acceptable by Seismic Walkdown Engineers (SWEs) because it could not have an unacceptable interaction with a safety related component. AR 2012-11363 issued to address housekeeping issue.

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

'ý- 4.."

George G Thomas Neda Stoeva Date:

08/15/2013 08/15/2013 D-264

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC) 11 D-265

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y-] N U Area Walk-By Checklist (AWC)

D-266

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: []

N U Area Walk-By Checklist (AWC)

Area 11 - AB2, 612, 12 - BY 2-NPS-111 D-267

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC) 11 -

D-268

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)

Area 11 D-269

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 11 - AB2, 612, 12 - BY 2-NPS-1 11 D-270

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - AB2, 609, 4 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Braces for pipe support seem like missing 2 bottom bolts each, but have welds at bottoms instead

2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-271

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [-* N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - AB2, 609, 4

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-272

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY-] N U Area Walk-By Checklist (AWC)

Area 13 -,

D-273

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: EKI N U Area Walk-By Checklist (AWC)

Area 13 - AB2, 609, 4 D-274

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: r7 N U Area Walk-By Checklist (AWC)

I-,I m 1111 11 1 W%4'.,IMI I1I1l D-275

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y-] N U Area Walk-By Checklist (AWC)

Area 13 - AB2, 609, 4 P9181015 D-276

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 13 - AB2, 609, 4 D-277

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 14 - AB2, 587, 40 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall with grate - OK per DWG 12-4026, Wall W-5.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-278

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [-Y] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 14 - AB2, 587, 40

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

yj-ý "George G Thomas

4.

Neda Stoeva Date:

10/18/12 10/18/12 D-279

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y] N U Area Walk-By Checklist (AWC) 14-D-280

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y EN U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 15 - AB2, 587, 41 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1.

Does anchorage of equipment in the area appear to be free of No potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

No nut on I of 4 bolts supporting 2-CS-301W-AR 2012-11780 was issued to address this issue.

2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Abandoned U-bolt partially cut above pump 2-PP-50W Judged not to be a seismic vulnerability. AR 2012-11691 issued.

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall with grate - OK per DWG 12-4026, Wall W-6.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-281

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2,01/13/14 Status:

Y I-* U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 15 - AB2, 587, 41

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments yj*b,.,

'j 4vZ

, Georme G Thomas Evaluated by:

Date:

08/15/2013

  • 3~4.

Neda Stoeva 08/15/2013 D-282

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y LNI1 U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 15 - AB2, 587, 41 P9180749 P9180750 D-283

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y F-] U Area Walk-By Checklist (AWC)

Area 15 -

D-284

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [-

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - AB2, 587, 43 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Pipe support downstream of 2-SI-1 15S is slightly warped by bottom left bolt. This is shown in Picture P9180885 below. Support warping likely due to heat from welding when installing support. Support capable of performing its function.

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?

D-285

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 16 - AB2, 587, 43

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments George G Thomas Evaluated by:

Date:

08/15/2013 4"4-Neda Stoeva 08/15/2013 D-286

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [*

N U Area Walk-By Checklist (AWC)

D-287

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC) 16 -

D-288

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 17 - AB2, 573, 52 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall - OK per DWG 12-4025, Wall W-22.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-289

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 17 - AB2, 573, 52

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-290

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [Y N U Area Walk-By Checklist (AWC) 17-,

W W-I M

'I I1"] I1I D-291

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y] N U Area Walk-By Checklist (AWC)

D-292

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y] N U Area Walk-By Checklist (AWC) rea 17 -

D-293

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 18 - AB2, 573, 55 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for-documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall - OK per DWG 12-4025, Wall W-24.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-294

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FYi N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 18 - AB2, 573, 55

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments George G Thomas Evaluated by:

Date:

10/18/12

  • 4-Neda Stoeva 10/18/12 D-295

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: t7YI N U Area Walk-By Checklist (AWC)

Area 18 -

D-296

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: -Y-] N U Area Walk-By Checklist (AWC) a 18 -1 D-297

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 19 - AB2, 609, 6 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinci)?

D-298

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: l N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 19 - AB2, 609, 6

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

2-ICM-321 outlet downstream pipe support bottom left comer bolt spalled concrete - AR#01 15039 and WO#55060450, previously evaluated for Use-As-Is.

Comments Evaluated by:

Evalatedby:George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-299

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FYI N U Area Walk-By Checklist (AWC)

I ý Iw I 1ýý I-C1,101 D-300

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Area 19 - AB2, 609, 6 D-301

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC)

Area 19_-

D-302

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 19 - AB2, 609, 6 D-303

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y L[-I U Area Walk-By Checklist (AWC)

Area 21 - AB2, 633, 633 BY 2-CFI -429 and 2-WMO-716 Location (Bldg, Elev, Room/Area):

and 2-WMO-718 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks by General area between 2-WMO-715 and 2-CFI-429 - AR 2012-11669 was issued.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-304

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y FR U Area Walk-By Checklist (AWC)

Area 21 - AB2, 633, 633 BY 2-CFI -429 and 2-WMO-716 Location (Bldg, Elev, Room/Area):

and 2-WMO-718

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/15/13 08/15/13 D-305

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y Wil] U Area Walk-By Checklist (AWC)

Area 21 - AB2, 633, 633 BY 2-CFI -429 and 2-WMO-716 D-306

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y [¶I U Area Walk-By Checklist (AWC)

Area 21 - AB2, 633, 633 BY 2-CFI 429 and 2-WMO-716 and 2-WMO-718 D-307

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y F U

Area Walk-By Checklist (AWC)

Area 21 - AB2, 633, 633 BY 2-CFI -429 and 2-WMO-716 and 2-WMO-718 D-308

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y N-] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 22 - AB2, 633, 8 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Cable trays lightly loaded

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks by MCCs - AR 2012-11669 was issued. Block wall behind 2-HV-AES-1 AND 2-HV-AES OK per DWG 12-4029, Wall W-7.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-309

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y FjJ U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 22 - AB2, 633, 8

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

Evaluated by:.George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-310

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y l U

Area Walk-By Checklist (AWC) 22-,

D-311

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y L[-1 U Area Walk-By Checklist (AWC) 22-D-312

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F]

N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 23 - AB2, 587, 126 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-313

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: E-I N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 23 - AB2, 587, 126

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by.

Eautdb:George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-314

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY] N U Area Walk-By Checklist (AWC) 23

  • D-315

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y j-U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 24 - AB2, 587, 122 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall on left side of room - OK per DWG 2-4036, Wall W-1 and Wall-W2.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-316

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y lI U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 24 - AB2, 587, 122

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-317

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y N U Area Walk-By Checklist (AWC)

Location (BIda. Elev, Room/Area):

Area 24 - AB2, 587, 122 P9140542 P9140543 w-UIAIP%!Aa D-318

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y FNZ U Area Walk-By Checklist (AWC) 24 -

D-319

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y N U Area Walk-By Checklist (AWC) 24-D-320

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status:

Y LlN U

Area Walk-By Checklist (AWC) 24-1 D-321