DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y jN U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 12 - TB1, 591, 50 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic No interactions that could cause flooding or spray in the area?
Fire protection - wet - threaded rod hung pipe - AR 2012-11738 was issued.
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.q., scaffoldincq, lead D-49
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y [E U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 12 - TBI, 591, 50 shielding)?
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
10/18/12 10/18/12 D-50
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y Li-II U Area Walk-By Checklist (AWC)
D-51
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y ¶] U Area Walk-By Checklist (AWC) 12-D-52
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y N-1 U Area Walk-By Checklist (AWC)
P9170033 D-53
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FYi] N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 13 - ABI, 609, 4 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1.
Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-54
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: ]-Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 13 - ABI, 609, 4
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments George G Thomas Evaluated by:
Date:
10/18/12 Neda Stoeva 10/18/12 D-55
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: LII N U Area Walk-By Checklist (AWC)
Area 13 -
"I-'
ujtU)d D-56
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y] N U Area Walk-By Checklist (AWC)
Area 13 -
D-57
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [-* N U Area Walk-By Checklist (AWC)
Location Bid Elev, Room/Area Are P9180972 a3 13 - ARI. 609-4
.=a t 3 - AB1. 609.4 D-58
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y-] N U
Area Walk-By Checklist (AWC)
Area 13 - AB1, 609, 4 D-59
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y-] N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 14 - ABI, 587, 40 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1.
Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall with grate - OK per DWG 12-4026, Wall W-2
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
De-pressurized well supported fire protection piping
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-60
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 14 - AB1, 587, 40 Crane parked and locked with C-clamp
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments George G Thomas Evaluated by:
Date:
10/18/12 E~~4 Neda Stoeva 10/18/12 D-61
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 14 - ABI, 587, 40 D-62
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: LI-I N U Area Walk-By Checklist (AWC) 14 -
D-63
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [-j N
U Area Walk-By Checklist (AWC) a 14 -I P9180733 D-64
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY-] N U
Area Walk-By Checklist (AWC) 11 D-65
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 15 - AB1, 587, 41 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall with grate - OK per DWG 12-4026, Wall W-3
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
De-pressurized well supported fire protection piping
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-66
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [y] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 15 - AB1, 587, 41 Crane parked and locked with C-clamp
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Georqe G Thomas Evaluated by:
Date:
10/18/12 4k4-Neda Stoeva 10/18/12 D-67
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: LIII N U Area Walk-By Checklist (AWC)
Area 15 -
P9180711 D-68
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F-] N U Area Walk-By Checklist (AWC) 15-P9180714 D-69
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: LI] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 16 - AB1, 587, 43 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Lack of thread engagement (minor) on pump as noted on 1-PP-26S
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall with grate - OK per DWG 12-4026, Wall W-9
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?
D-70
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y-] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 15 - AB1, 587, 41
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments George G Thomas Evaluated by:
Date:
10/18/12 Neda Stoeva 10/18/12 11WIbUý1I*
P9180915 D-71
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: r-Y N U Area Walk-By Checklist (AWC) 15-)
DA4I nn4
-7 D-72
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y-] N U Area Walk-By Checklist (AWC)
Area 15-P9180923 P9180924 D-73
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: `] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Instructions for Completing Checklist Area 17 - ABI, 573, 52 This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findinqs. Additional space is provided at the end of this checklist for documentinq other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall with grate - OK per DWG 12-4025, Wall W-2
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead Yes D-74
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 17 - ABI, 573, 52 shielding)?
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Date:
10/18/12 Neda Stoeva 10/18/12 D-75
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY] N U Area Walk-By Checklist (AWC) 17-.
D-76
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FYI] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 17 - ABI, 573, 52 D-77
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 18 - AB1, 573, 55 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall with grate - OK per DWG 12-4025, Wall W-4
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?
D-78
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [y] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 18 -ABI, 573, 55
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
Evaluated by:_
George G Thomas Neda Stoeva Date:
10/18/12 10/18/12 D-79
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F-] N U
Area Walk-By Checklist (AWC) 18-)
P9180844 D-80
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: l]
N U Area Walk-By Checklist (AWC)
I nAcfinn (RIri'n Phl Rnnm/ArnV Area 18 - ABI, 573, 55 P9180849 D-81
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: T N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Instructions for Completing Checklist Area 19 - ABI, 609, 6 This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes D-82
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y_] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 19 - ABI, 609, 6
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments George G Thomas Evaluated by:
Date:
10/18/12
(*k"+
Neda Stoeva 10/18/12 D-83
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1,09/12/13 Status: 7Y N U Area Walk-By Checklist (AWC) 19-D-84
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY] N U Area Walk-By Checklist (AWC) iI D-85
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y W-J U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 20 - AB2, 609, BY 1-PP-1 OW Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Minor rust on 1-HE-15E south-east and south west bolts. 1-WFI-731-IN rack - base plate has 4 bolts - I of which has no nut or room to put one on - OK approved as is by engineering under 5CRP DOC# 00-10940
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic No interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-86
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y EIE U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 20 - AB2, 609, BY 1-PP-1OW Fire extinguishers on short hooks - AR 2012-11669 was issued.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Sprinkler head near 20 PSI CA by 1-HE-15E - depressurized but fire piping & sprinkler vibrate and could impact 20 PSI CA, possibly damage sprinkler head - but OK because not charged Comments Evaluated by:
George G Thomas E
J*'AI)
Neda Stoeva Date:
10/18/12 10/18/12 D-87
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y EN-U Area Walk-By Checklist (AWC) 20 -
D-88
Area Walk-By Checklist (AWC)
Area 20 DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
YEN-] U
- AB2, 609, BY 1-PP-1OW P9100036 P9100038
"-IUUUl
(
D-89
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y LNI U Area Walk-By Checklist (AWC) rea 20 - )
I-lu'1 I it If Ild'-
D-90
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y
] U Area Walk-By Checklist (AWC)
Location OBIda, Elev, Room/Area):
Area 20 - AB2, 609, BY 1-PP-1OW D-91
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 21 - ABI, 633-By 1-WMO-715 A
Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Threads not fully engaged on supports for 1-WMO-711 and minor rust.
OK by engineering - no DOC# on tag. There was at least Y4 thread engagement in the nut, enough to develop the full strength of the bolt.
Lack of DOC# on tag a documentation in the field issue only.
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldina)?
D-92
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: E[i N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 21 - AB1, 633 - By 1-WMO-715
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Neda Stoeva Date:
08/15/2013 08/15/2013 D-93
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F]
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
21
_JA P9100132
"'I UU-1533 D-94
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F]
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Aran 91 - ARI 9* -
- 1.
IWMn-71.r IA P9100137 D-95
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y-] N U
-WMO-715 A
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
21 D-96
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 21 - ABI, 633-By 1-WMO-715 I\\A P9100146 D-97
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y N-U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 22 - AB2, 633, 633 by 12-HV-ACCP-3 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers behind Concentrator 7 on semi-short hooks (longer than other areas) - AR 2012-11669 was issued.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-98
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y EiI U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 22 - AB2, 633, 633 by 12-HV-ACCP-3
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
Is','
George G Thomas Neda Stoeva Date:
10/18/12 10/18/12 D-99
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y L* U Area Walk-By Checklist (AWC) 22 -,
P9100187 D-100
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y Ei] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 23 - AB1, 587, 121 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall - OK per DWG 1-4033, Wall W-3 and Wall W-4
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
C02 fire protection
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-101
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y LN] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 23 - ABI, 587, 121
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
George G Thomas Date:
08/15/2013 Sý4_ Neda Stoeva 08/15/2013 D-102
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y EN U
Area Walk-By Checklist (AWC) w %4
-1At I-1.1 hN4 D-103
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y EN-U Area Walk-By Checklist (AWC) 23-P9130267 D-104
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y
] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 23 - AB1, 587, 121 D-105
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y LNII U Area Walk-By Checklist (AWC) 23-I-'-4i l :
I/' 111 D-106
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y [
U Area Walk-By Checklist (AWC)
Area 23 - ABI, 587, 121 D-107
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y [j]
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 24 - ABI, 587, 122 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall - OK per DWG 1-4033, Wall W-1 and Wall W-2. Ceiling light rod hung above MCC on right side of door could swing but OK because there is a steel angle installed to prevent it from hitting MCC
- 5.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
D-108
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y LE] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area 24 - AB1, 587, 122
- 7.
Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
vauebyGeorge G Thomas Neda Stoeva Date:
10/18/12 10/18/12 D-109
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y FN_
U Area Walk-By Checklist (AWC) 24 - )
D-110
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y
_-J] U Area Walk-By Checklist (AWC)
Location Bid Elev, Room/Area Area 24 - AB1, 587, 122 I-M'l I Il AIp%/
P9130365 D-111
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y F-NI U Area Walk-By Checklist (AWC)
D-112
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y ¶111 U Area Walk-By Checklist (AWC)
I nrtinnn (PI::imlow Pnnm/Arn Area 24 -ABI, 587, 122 D-113
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:
Y El] U Area Walk-By Checklist (AWC) 24 - )
D-114