AEP-NRC-2014-08, SD-121023-001, Rev. 2, in Response to the 50.54(f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.3: Seismic for the D. C. Cook Unit 1 and 2, Page D-322 Through Page D-404
ML14035A370 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 01/13/2014 |
From: | Yates L American Electric Power |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML14035A350 | List:
|
References | |
AEP-NRC-2014-08 SD-121023-001, Rev 2 | |
Download: ML14035A370 (83) | |
Text
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y I-N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 25 - AB2, 633, 123 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Panels welded to embedded plates
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers OK - long seismic hooks. Block wall - OK per DWG 12-4029, Wall W-13.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic No interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?
D-322
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y fj ] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 26 - AB2, 633, 123 Fire extinguishers mounted to side of control panels (seismic hooks, but can be an interaction)- Addressed in AR 2012-11730. Big Emergency cart with 4 chocked wheels - small procedure cart chained off to it (no chocked wheels) and TOO CLOSE TO PANEL - Addressed in AR 2012-11726.
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Between 2-NIS-1 and IV panel there are missing bolts connecting the two panels together, but nuts are there (between 2 panels) - needs investigation- AR 2012-11726 was issued to investigate found conditions.
Comments Evaluated by: Eva*luate by:-George G Thomas Date: 10/18/12
- 4 - Neda Stoeva 10/18/12 D-323
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LI- U Area Walk-By Checklist (AWC)
D-324
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y r-N1 U Area Walk-By Checklist (AWC)
Location Bid , Elev Room/Area: Area 25 - AB2, 633,123 D-325
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶IIl U Area Walk-By Checklist (AWC)
I ;
P9181106 t*1*11 l/
D-326
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y I U Area Walk-By Checklist (AWC)
Area 25 - AB2, 633, 123 I"o 10 -:1 1 Utp D-327
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y El] U Area Walk-By Checklist (AWC)
Area 25 - AB2, 633, 123 ri" oi
- I D-328
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y I U Area Walk-By Checklist (AWC)
Area 25 - AB2, D-329
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y El] U Area Walk-By Checklist (AWC)
Area 25 -
D-330
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ENl U Area Walk-By Checklist (AWC) 25 P9181119 D-331
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y fN- U Area Walk-By Checklist (AWC)
Area 25 1tiilI1ZI D-332
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LII U Area Walk-By Checklist (AWC)
Area 25 - AE D-333
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LEJ U Area Walk-By Checklist (AWC) 3_'
D-334
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y FI_ U Area Walk-By Checklist (AWC)
Area 25 - AB2, D-335
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y EN*] U Area Walk-By Checklist (AWC)
Area 25.-
D-336
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶r- U Area Walk-By Checklist (AWC)
Area 25 -,
D-337
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [-* U Area Walk-By Checklist (AWC)
Location (Bida. Elev. Room/Area): Area 25 - AB2. 633. 123 D-338
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 26 - SH2, 591, 135 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-339
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: E-I N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 26 - SH2, 591,135
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: 4"ý
- George G Thomas Date: 10/18/12
- 4- Neda Stoeva 10/18/12 D-340
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY] N U Area Walk-By Checklist (AWC)
Location (Bida. Elev. Room/Area): Area 26 - SH2. 591. 135 P9090100 P9090101 1UfU1 UZ D-341
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y L[- U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 27 - AB2, 609, 609 BY 2-PP-1OW Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
12-TK- 14-1, 12-TK-14-2, 12-TK-14-3, and 12-TK-14-4 flood hazard analysis? - Determined that flooding would not affect any critical components, because they are lifted off the ground, and flood mitigation paths are in place to prevent flood water to rise to the elevation of safety relatedcomponents.
- 6. Does it appear that the area is free of potentially adverse seismic No interactions that could cause a fire in the area?
Fire wall between CCW pumps and spare CCW pump - DWG 12-4028 Fire Barrier.Fire extinguishers on short hooks north west side of 2-HE-15W- AR 2012-11669 was issued.
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead D-342
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LIE U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 27 - AB2, 609, 609 BY 2-PP-1OW shielding)?
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Fire protection well supported, cable tray lightly loaded Evaluated by: Evalatedby:George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-343
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ] U Area Walk-By Checklist (AWC)
Area 27 - AB2, 609, 609 BY 2-PP-D-344
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y FNI] U Area Walk-By Checklist (AWC) a 27 - )
D-345
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶I* U Area Walk-By Checklist (AWC)
Area 27 -
I ýj I %JJW I Ij D-346
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y IF- U Area Walk-By Checklist (AWC)
Location (B1da. Elev. Room/Area): Area 27 - AB2, 609, 609 BY 2-PP-1OW D-347
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: *- N U (AWC)
Area Walk-By Checklist Location (BEldg, Elev, Room/Area): Area 28 - AB2, 609, 200 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Visible anchorageOK - mostly internal anchoragein area and cannot confirm condition
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-348
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: L] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 28 - AB2, 609, 200
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: " I-- George G Thomas Date: 10/18/12 4 " Neda Stoeva 10/18/12 D-349
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [* N U Area Walk-By Checklist (AWC)
Location (Bldq, Elev, Room/Area): Area 28 - AB2, 609, 200 P9170850 P9170851 D-350
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [-J N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 29 - AB2, 609, 202 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Minor spalling on right side (2) bolts of 2-CCRP-CVT
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-351
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y-] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 29 - AB2, 609, 202
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: 4-,ý* George G Thomas Date: 10/18/12 4 "4 Neda Stoeva 10/18/12
-352
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: FY-] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 29 - AB2, 609, 202 P9170872 P9170873 D-353
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [-N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 30 - AB2, 633, 633 - GENERAL Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Most components in area are internally anchored. Some components have been modified with external anchorageand are OK
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
Fire protection piping is wet but not pressurized
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-354
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y iN- U Area Walk-By Checklist (AWC)
Location (Blda. Elev. Room/Area): Area 30 - AB2. 633. 633 - GENERAL
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-355
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y I-f U Area Walk-By Checklist (AWC) a ý D-356
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y F U Area Walk-By Checklist (AWC) 30 D-357
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y N U Area Walk-By Checklist (AWC)
I D-358
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LNW U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 31 - AB2, 613, 205 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of No potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
MCC-2-PHC-1 Check anchorageanalysis (HAS 8 holes for bolts, but only has 6 bolts installed)- could not verified if this was an analyzed condition, so AR 2012-11782 was issued.
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Most equipment in area internallyanchored- Externally anchored equipment is OK
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks by MCC and by 600V BUS 21B - AR 2012-11669 was issued. Rod hung light can swing into MCC Unit 2-EZC-CS - would not be damaging (perAEP team).
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-359
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y FN] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 31 - AB2, 613, 205
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-360
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ] U Area Walk-By Checklist (AWC) 31 D-361
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y I-E U Area Walk-By Checklist (AWC)
Area 31 -
D-362
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y N-] U Area Walk-By Checklist (AWC)
Area 31 - AB2, 613, 205 D-363
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 32 - SH2, 594, 221 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-364
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F-] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 32 - SH2, 594, 221
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Magnet with life saving hook on 2-PS-D Evaluated by: S'&--"- George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-365
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [lI N U Area Walk-By Checklist (AWC)
Area 32 - SH2, 594, D-366
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 33 - AB2, 650, 129 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Bolt surface corrosion on right second bolt of 2-HV-ACRA-1, and first and second spacers/washerssurface rust on left side. Anchorage judged acceptable,rust did not degrade capacity. AR 2012-11212 issued.
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Block wall - retrofitted - OK per DWG 12-403 1, Wall W-2.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?
D-367
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: EY-] N U Area Walk-By Checklist (AWC)
Location (Bidg, Elev, Room/Area): Area 33 - AB2, 660, 129
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by. EaadyGeorge G Thomas Date: 08/15/2013 Neda Stoeva 08/15/2013 D-368
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: 7Y N U Area Walk-By Checklist (AWC)
Location.(Bldg, Elev, Room/Area): Area 33 - AB2, 660, 129 P9100149 P9100150 D-369
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [* N U Area Walk-By Checklist (AWC)
II D-370
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y N-] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 34 - AB2, 587, 121 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Support by back left comer of DG has deficiency tag - NRC also questioned it. Rack supportingpipes for 2-XRV-232 AND 2-XRV-231 has I bolt with minor lack of thread engagement. Support for 2-Q T-134-AB - I bolt not fully engaged - OK'd by engineeringand tagged because it would not cause an unacceptableseismic interaction. AR 2012-11485 issued.
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall on left side of room - OK per DWG 2-4036, Wall W-4 and Wall W-
- 5. Ceiling light by right back comer has an open hook - OK because it cannot slip off - opening is at an angle towards the top of hook.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes D-371
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LN U Area Walk-By Checklist (AWC)
Location (Bldq, Elev, Room/Area): Area 34 - AB2, 587,121 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evauat4dby George G Thomas Evaluated by: Date: 08/15/2013
- 4 - Neda Stoeva 08/15/2013 D-372
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [N U Area Walk-By Checklist (AWC)
D-373
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y El] U Area Walk-By Checklist (AWC) 134.
V&14UOU1 D-374
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [Nl U Area Walk-By Checklist (AWC) 34-D-375
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [NI1 U Area Walk-By Checklist (AWC)
Area 34 - AB2, 587 VU14MUIZ D-376
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y O U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 34 - AB2, 587, 121 D-377
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 35 - AB2, 587, 126 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinci?
D-378
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: ] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 35 - AB2, 587, 126 Seismic scaffold next to DG - signed, tied off, stable
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: * '" George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-379
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [-] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 36 - AB2, 609, 204 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall between 2-TR21A & 2-TR21C - OK per DWG 12-3253 and 12-3254, Section D-4.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-380
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y FNT] U Area Walk-By Checklist (AWC)
Location (Blda. Elev. Room/Area): Area 36 - AB2. 609, 204
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-381
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [-N- U Area Walk-By Checklist (AWC)
D-382
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶_] U Area Walk-By Checklist (AWC) 36 D-383
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ENl U Area Walk-By Checklist (AWC)
Location (Bidi., Elev, Room/Area): Area 36 - AB2, 609, 204 D-384
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y j-] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 37 - AB2, 609, 96 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Check that crane 12-QM-23 is parked properly (away from SFP pit)
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
Panel 12-SFP Verified As-Is anchorage configuration with SQUG 12-SFP-12 data sheet - AR 2012-12381 issued to update drawing 12-5636.
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Wall around SFP pit - Block wall - OK per DWG 12-4027, Wall W- 14.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-385
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ] U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 37 - AB2, 609, 96
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Boric acid on 22-PP taped off as contaminated Evaluated by: George G Thomas Date: 10/18/12 Neda Stoeva 10/18/12 D-386
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ON] U Area Walk-By Checklist (AWC) 37 D-387
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y L1 U Area Walk-By Checklist (AWC)
Area 37 -
D-388
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y E U Area Walk-By Checklist (AWC) rea 37 -,
D-389
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶j] U Area Walk-By Checklist (AWC) 37 D-390
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 38 - AB2, 586, 24 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-391
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: [] N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 38 - AB2, 586, 24
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments AREA ONLY 30' OF COMPONENT Evaluated by: George G Thomas Date: 10/18/12
- 4- Neda Stoeva 10/18/12 D-392
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F-] N U Area Walk-By Checklist (AWC)
Area 38 - AB2 D-393
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: F N U Area Walk-By Checklist (AWC) a, D-394
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [jJ U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 39 - AB1, 587, 35 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.
The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2. Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?
- 3. Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall - OK per DWG 12-3253 and 12-3254 Section D-4.
- 5. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?
1-TK-36 is right by panel but well supported
- 6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
- 7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
D-395
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y j_ U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area): Area 39 - ABI, 587, 35
- 8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by: * '*t"* George G Thomas Date: 08/15/2013 Neda Stoeva 08/15/2013 D-396
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶IJ U Area Walk-By Checklist (AWC) 39 D-397
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y LN- U Area Walk-By Checklist (AWC)
Area 39 -
D-398
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶NI] U Area Walk-By Checklist (AWC) 39_ -
D-399
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ] U Area Walk-By Checklist (AWC)
Area 39 - ABI, D-400
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ¶I_ U Area Walk-By Checklist (AWC) 39 -)
D-401
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y [-N U Area Walk-By Checklist (AWC) 39-D-402
DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ENl U Area Walk-By Checklist (AWC)
- a39 -)
D-403
DC Cook Unit I & Unit 2 SD-121023-001 Rev. 2, 01/13/14 Status: Y ENl U Area Walk-By Checklist (AWC) 39-D-404