DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 26 - SH2, 591, 135 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-339

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y-] N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 26 - SH2, 591, 135

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-340

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: LY] N U Area Walk-By Checklist (AWC) 2 FU*U1UZ D-341

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y N-] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 27 - AB2, 609, 609 BY 2-PP-1OW Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

12-TK-14-1, 12-TK-14-2, 12-TK-14-3, and 12-TK-14-4 flood hazard analysis? - Determined that flooding would not affect any critical components, because they are lifted off the ground, and flood mitigation paths are in place to prevent flood water to rise to the elevation of safety related components.

6. Does it appear that the area is free of potentially adverse seismic No interactions that could cause a fire in the area?

Fire wall between CCW pumps and spare CCW pump - DWG 12-4028 Fire Barrier. Fire extinguishers on short hooks north west side of 2-HE-15W-AR 2012-11669 was issued.

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of D-342

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y [N-] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 27 - AB2, 609, 609 BY 2-PP-1OW portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Fire protection well supported, cable tray lightly loaded George G Thomas Evaluated by:

Date:

10/18/12 64ý41_

Neda Stoeva 10/18/12 D-343

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y E]

U Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Area):

Area 27 - AB2. 609. 609 BY 2-PP-1 OW Y

Y D-344

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y []

U Area Walk-By Checklist (AWC)

Area 27 -

Mnfnnn7n D-345

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1,09/12/13 Status:

Y l U

Area Walk-By Checklist (AWC) 27-D-346

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y ¶NJ U Area Walk-By Checklist (AWC)

Location Oda. Elev. Room/Area):

Area 27 - AB2, 609, 609 BY 2-PP-1OW D-347

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: jYJ N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 28 - AB2, 609, 200 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Visible anchorage OK - mostly internal anchorage in area and cannot confirm condition

2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-348

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 28 - AB2, 609, 200

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Date:

10/18/12 Neda Stoeva 10/18/12 P9170848 D-349

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F]

N U Area Walk-By Checklist (AWC)

Area 28 -

D-350

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1,09/12/13 Status:

V N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 29 - AB2, 609, 202 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Minor spalling on right side (2) bolts of 2-CCRP-CVT

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-351

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F-* N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 29 - AB2, 609, 202

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Georqe G Thomas Evaluated by:

Date:

10/18/12

ýý,'4-Neda Stoeva 10/18/12 F~jl Iut5(u

ýI-'E 1 1 UZ5 V D-352

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: [Y-] N U Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Are Area 29 - AB2, I-"1 /UZ(4 D-353

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y L_- U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 30 - AB2, 633, 633 - GENERAL Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Most components in area are internally anchored. Some components have been modified with external anchorage and are OK

2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

Fire protection piping is wet but not pressurized

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-354

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y ENl U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 30 - AB2, 633, 633 - GENERAL

8. Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments George G Thomas Evaluated by:

Date:

10/18/12 E~~4 Neda Stoeva 10/18/12 D-355

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y [N U

Area Walk-By Checklist (AWC) 30 - AB2, 633, 633 - GENERAL D-356

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y [-* U Area Walk-By Checklist (AWC)

D-357

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y E-_

U Area Walk-By Checklist (AWC) 30-

?*1";.'

I I IT.

D-358

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y jNj U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 31 - AB2, 613, 205 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of No potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

MCC-2-PHC-1 Check anchorage analysis (HAS 8 holes for bolts, but only has 6 bolts installed) - could not verified if this was an analyzed condition, so AR 2012-11782 was issued.

2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Most equipment in area internally anchored - Externally anchored equipment is OK

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks by MCC and by 600V BUS 21B - AR 2012-11669 was issued. Rod hung light can swing into MCC Unit 2-EZC-CS - would not be damaging (per AEP team).

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-359

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y LNZ U Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Area):

Area 31 - AB2. 613. 205

8.

Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Comments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-360

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y L* U Area Walk-By Checklist (AWC)

"I- [Ud3b D-361

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y ¶1! U Area Walk-By Checklist (AWC)

Location (BIda. Elev. Room/Area):

Area 31 - AB2. 613. 205 1

D-362

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y

] U Area Walk-By Checklist (AWC)

D-363

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Fjj] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 32 - SH2, 594, 221 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-364

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: []

N U

Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Area/:

Area 32 - SH2, 594, 221 Location (Blda Elev Roo /Area):

I I

8.

Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Comments Magnet with life saving hook on 2-PS-D Evaluated by:

George G Thomas ywI.At%

Neda Stoeva Date:

10/18/12 10/18/12 D-365

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: FY-] N U Area Walk-By Checklist (AWC)

D-366

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y-] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 33 - AB2, 650, 129 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Bolt surface corrosion on right second bolt of 2-HV-ACRA-1, and first and second spacers/washers surface rust on left side. Anchorage judged acceptable, rust did not degrade capacity. AR 2012-11212 issued.

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall - retrofitted - OK per DWG 12-403 1, Wall W-2.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-367

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: 7Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 33 - AB2, 650, 129

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Neda Stoeva Date:

08/15/2013 08/15/2013 D-368

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y1 N U Area Walk-By Checklist (AWC) 33-D-369

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y] N U Area Walk-By Checklist (AWC) 33-D-370

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y E-] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 34 - AB2, 587, 121 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Support by back left comer of DG has deficiency tag - NRC also questioned it. Rack supporting pipes for 2-XRV-232 AND 2-XRV-231 has I bolt with minor lack of thread engagement. Support for 2-Q T-134-AB - I bolt not fully engaged - OK'd by engineering and tagged because it would not cause an unacceptable seismic interaction. AR 2012-11485 issued.

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall on left side of room - OK per D WG 2-4036, Wall W-4 and Wall W-

5. Ceiling light by right back comer has an open hook - OK because it cannot slip off - opening is at an angle towards the top of hook.
5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

D-371

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y []

U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 34 - AB2, 587, 121

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
8.

Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Yes Comments Evaluated by:

Evauaed" bGeorge G Thomas Neda Stoeva Date:

08/15/2013 08/15/2013 D-372

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y Wil U Area Walk-By Checklist (AWC)

Location Bid Elev, Room/Area Area 34 - AB2, 587, 121 P91490 P9140491 P9140492 P9140493 P9140494 P9140495 D-373

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y E-U Area Walk-By Checklist (AWC) 34-D-374

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y FI1 U Area Walk-By Checklist (AWC)

Location Bid Elev, Room/Area):

Area 34 - AB2, 587, 121 P9140502 P9140503 P9140504 P9140505 P9140506 P9140507 D-375

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y [-N U

Area Walk-By Checklist (AWC)

Area 34 - AB2, D-376

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y FNE U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 34 - AB2, 587, 121 P9140514 D-377

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1,09/12/13 Status: El] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 35 - AB2, 587, 126 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-378

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: F]

N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 35 - AB2, 587, 126 Seismic scaffold next to DG - signed, tied off, stable

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Evaluated by:

George G Thomas Date:

10/18/12 Neda Stoeva 10/18/12 D-379

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y Lj` U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 36 - AB2, 609, 204 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall between 2-TR21A & 2-TR21C - OK per DWG 12-3253 and 12-3254, Section D-4.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-380

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y r-j U Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Area'i:

Area 36 - AB2. 609. 204 Location (Bldo Elev Roo /Area):

Area 36 - AB2, 609, 204

8.

Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Cornments Evaluated by:

George G Thomas Neda Stoeva Date:

10/18/12 10/18/12 D-381

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y

] U Area Walk-By Checklist (AWC)

Area 36 - AB2, 609, 204 P9170885 D-382

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y lNI U

Area Walk-By Checklist (AWC)

Area 36 - AB2, 609, 204

ýIu lub5dd D-383

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

YEN-] U Area Walk-By Checklist (AWC)

Location (Bidq, Elev, Room/Area):

Area 36 - AB2, 609, 204 D-384

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y EN] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 37 - AB2, 609, 96 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Check that crane 12-QM-23 is parked properly (away from SFP pit)

2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

Panel 12-SFP Verified As-Is anchorage configuration with SQUG 12-SFP-12 data sheet - AR 2012-12381 issued to update drawing 12-5636.

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued. Wall around SFP pit - Block wall - OKperDWG 12-4027, Wall W-14.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?
7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead D-385

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y

] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 37 - AB2, 609, 96 shielding)?

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Boric acid on 22-PP taped off as contaminated George G Thomas Evaluated by:

Date:

10/18/12 Neda Stoeva 10/18/12 D-386

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y LN U Area Walk-By Checklist (AWC) 37-D-387

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y FN] U Area Walk-By Checklist (AWC)

Location (Blda. Elev. Room/Area):

Area 37 - AB2. 609. 96 1

9 D-388

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y N U Area Walk-By Checklist (AWC)

Area 37 -

D-389

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y LN-U Area Walk-By Checklist (AWC)

D-390

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y] N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 38 - AB2, 586, 24 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic Yes spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

D-391

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: IY-N U Area Walk-By Checklist (AWC)

Location (Blda, Elev. Room/Area):

Area 38 - AB2. 586. 24

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Comments AREA ONLY 30' OF COMPONENT Evaluated by:

George G Thomas E

.)AA4 Neda Stoeva Date:

10/18/12 10/18/12 D-392

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y] N U Area Walk-By Checklist (AWC)

P9180897 D-393

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y N U Area Walk-By Checklist (AWC) 3 ;

D-394

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y

] U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area 39 - ABI, 587, 35 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items.

The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Yes potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of Yes significant degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit Yes raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic No spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fire extinguishers on short hooks - AR 2012-11669 was issued. Block wall - OK per DWG 12-3253 and 12-3254 Section D-4.

5.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause flooding or spray in the area?

1-TK-36 is right by panel but well supported

6.

Does it appear that the area is free of potentially adverse seismic Yes interactions that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic Yes interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shieldinq)?

D-395

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y j]

U Area Walk-By Checklist (AWC)

Location (Blda, Elev, Room/Area):

Area 39 - AB1. 587. 35

8.

Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Yes Comments Evaluated by:

George G Thomas Date:

08/15/2013 Neda Stoeva 08/15/2013 D-396

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y r-* U Area Walk-By Checklist (AWC) 39-I 0 UOI D-397

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y F U

Area Walk-By Checklist (AWC)

Location (Bida. Elev. Room/Area):

Area 39 - ABI. 587. 35 9

D-398

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y *-] U Area Walk-By Checklist (AWC)

Location (Bldq, Elev, Room/Area):

Area 39 - ABI, 587, 35 P9181035 D-399

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y Li* U Area Walk-By Checklist (AWC) 39-D-400

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y [-II U Area Walk-By Checklist (AWC)

Location (Bidg, Elev, Room/Area):

Area 39 - ABI, 587, 35 FtJI b I U41 FU11b1U4Z D-401

DC Cook Unit I & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status: Y-N-] U Area Walk-By Checklist (AWC) 39 - AB1 D-402

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y L-] U Area Walk-By Checklist (AWC) 39-Iu 1

-I U4/

D-403

DC Cook Unit 1 & Unit 2 SD-121023-001 Rev. 1, 09/12/13 Status:

Y ¶N-] U Area Walk-By Checklist (AWC)

Location (Bldo. Elev. Room/Area):

Area 39 - AB1, 587, 35 F-illuol D-404