Compilation of Industry Provided Information on Anchor Darling Double Disc Gate Valve Population Affected by Flowserve, Part 21 Issue of Wedge Pin Failure on an Anchor Darling Double Disc Gate Valve in Report Format with Valve Count
ML18053A023
Person / Time
Site: Beaver Valley, Millstone, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Grand Gulf, Sequoyah, Pilgrim, Arkansas Nuclear, Braidwood, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, North Anna, Turkey Point, Ginna, Diablo Canyon, Callaway, Vogtle, Duane Arnold, Farley, Clinton, South Texas, San Onofre, Cook, Quad Cities, McGuire, LaSalle  
Issue date: 02/22/2018
From: Michael Farnan
NRC/NRR/DE/EMIB
To:
Farnan M, NRR/DE/EMIB 301-415-1486
References
Download: ML18053A023 (71)


Text

Anchor Darling Double Disc Gate Valve Population Information Owner/Operator PLANT Dkt #

Ameren UE Callaway 1 483 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments EGHV0058 Component Cooling Water (CCW)

CCW to Containment Outer Isolation 12 Close L

Yes No Yes < or

= 5 deg.

Not Repaired Repairs tentatively planned for next refueling outage in Spring of 2019 EGHV0059 Component Cooling Water (CCW)

CCW to Containment Outer Isolation 12 Close L

Yes Yes < or =

0.10 Yes < or

= 5 deg.

Not Repaired Thread friction COF of 0.42 was credited in evaluation showing torque applied during a 2010 stall event was not adequate to fail pin. However, the evaluation remains SAT if COF-0.1.

Additionally, the pin's shear torque excluding thread friction has 80% margin over design basis torque. Repairs tentatively planned for outage in Spring of 2019.

EGHV0060 Component Cooling Water (CCW)

CCW from Reactor Coolant System from Containment Inner Isolation 12 Close L

Yes No Yes < or

= 5 deg.

Not Repaired Repairs tentativel planned for next refueling outage in Spring of 2019.

Total # of Valves 3

Total # of Valves Repaired 0

Total # of Valves Not Repaired 3

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 3

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 3

Total # of Valves N/A 0

Total # of Valves 3

Total # of Valves Repaired 0

Total # of Valves Not Repaired 3

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 3

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 3

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Arizona Public Service Co.

Palo Verde 1 528 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Wednesday, February 21, 2018 Page 1 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Palo Verde 2 529 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Palo Verde 3 530 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Dominion Generation Millstone 2 336 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 2 of 71

Owner/Operator PLANT Dkt #

2-CS-13.1A Containment Spray RWST Outlet Header "A" Isolation Valve 18 Close M

No Yes > 0.10 No Not Repaired 2-CS-13.1B Containment Spray RWST Outlet Header "B" Isolation Valve 18 Close M

No Yes > 0.10 No Not Repaired 2-CS-16.1A Containment Spray Containment Sump Outlet Header "A" Isolation Valve 24 Both H

No Yes < or =

0.10 No Not Repaired 2-CS-16.1B Containment Spray Containment Sump Outlet Header "B" Isolation Valve 24 Both H

No Yes < or =

0.10 No Not Repaired 2-CS-4.1A Containment Spray "A" Containment Spray Header Isolation Valve 8

Both H

No Yes > 0.10 No Not Repaired 2-CS-4.1B Containment Spray "B" Containment Spray Header Isolation Valve 8

Both H

No Yes > 0.10 No Not Repaired Total # of Valves 6

Total # of Valves Repaired 0

Total # of Valves Not Repaired 6

Total # High Risk Valves 4

Total # Med Risk Valves 2

Total # Low Risk Valves 0

Total Thread Fric > 0.10 4

Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 0

Total # of Valves N/A 0

Millstone 3 423 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

North Anna 1 338 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1-RH-MOV-1720A Residual Heat Removal (RHR)

RHR to "B" RCS Loop 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

Wednesday, February 21, 2018 Page 3 of 71

Owner/Operator PLANT Dkt #

1-RH-MOV-1720B Residual Heat Removal (RHR)

RHR to "C" RCS Loop 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

1-SI-MOV-1890A Safety Injection (SI) Low Head SI Hot Leg Injection Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

1-SI-MOV-1890B Safety Injection (SI) Low Head SI Hot Leg Injection Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

1-SI-MOV-1890C Safety Injection (SI) Low Head SI Cold Leg Injection Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

1-SI-MOV-1890D Safety Injection (SI) Low Head SI Cold Leg Injection Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

Total # of Valves 6

Total # of Valves Repaired 0

Total # of Valves Not Repaired 6

Total # High Risk Valves 0

Total # Med Risk Valves 2

Total # Low Risk Valves 4

Total Thread Fric > 0.10 6

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

North Anna 2 339 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-RH-MOV-2720A Residual Heat Removal (RHR)

RHR to "B" RCS Loop 8

Open M

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10.

2-RH-MOV-2720B Residual Heat Removal (RHR)

RHR to "C" RCS Loop 8

Open M

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10.

2-SI-MOV-2890A Safety Injection (SI) Low Head SI Hot Leg Injection Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Repaired Valve size is 10 X 8 X 10.

2-SI-MOV-2890B Safety Injection (SI) Low Head SI Hot Leg Injection Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10.

2-SI-MOV-2890C Safety Injection (SI) Low Head SI Cold Leg Injection Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10.

2-SI-MOV-2890D Safety Injection (SI) Low Head SI Cold Leg Injection Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10.

Wednesday, February 21, 2018 Page 4 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 6

Total # of Valves Repaired 1

Total # of Valves Not Repaired 5

Total # High Risk Valves 0

Total # Med Risk Valves 2

Total # Low Risk Valves 4

Total Thread Fric > 0.10 6

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Surry 1 280 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 01-CH-MOV-1289A Charging Main Charging Header Isolation 3

Close L

No Yes > 0.10 No Not Repaired 01-CH-MOV-1289B Charging Main Charging Header Isolation 3

Close L

No Yes > 0.10 No Not Repaired 01-RH-MOV-1720A Residual Heat Removal (RHR)

RHR Outlet Isolation to Accumulator Discharge Line 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

01-RH-MOV-1720B Residual Heat Removal (RHR)

RHR Outlet Isolation to Accumulator Discharge Line 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

01-SI-MOV-1864A Safety Injection (SI) Low Head SI Pump Cold Leg Discharge Stop Valve 10 Both L

No No No Not Repaired 01-SI-MOV-1864B Safety Injection (SI) Low Head SI Pump Cold Leg Discharge Stop Valve 10 Both L

No Yes > 0.10 No Not Repaired 01-SI-MOV-1867C Safety Injection (SI) High Head SI to Reactor Coolant System (RCS) Cold Legs 3

Both H

No No No Not Repaired 01-SI-MOV-1867D Safety Injection (SI) High Head SI to Reactor Coolant System (RCS) Cold Legs 3

Both H

No Yes > 0.10 No Not Repaired 01-SI-MOV-1869A Safety Injection (SI) High Head SI to Reactor Coolant System (RCS) Hot Legs 3

Both L

No Yes > 0.10 No Not Repaired 01-SI-MOV-1890A Safety Injection (SI) Low Head SI Pump Hot Leg Discharge Stop Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

01-SI-MOV-1890B Safety Injection (SI) Low Head SI Pump Hot Leg Discharge Stop Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

01-SI-MOV-1890C Safety Injection (SI) Low Head SI Pump Hot Leg Discharge Stop Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

Wednesday, February 21, 2018 Page 5 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 12 Total # of Valves Repaired 0

Total # of Valves Not Repaired 12 Total # High Risk Valves 2

Total # Med Risk Valves 2

Total # Low Risk Valves 8

Total Thread Fric > 0.10 10 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Surry 2 281 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 02-CH-MOV-2115B Charging Charging Pump Supply from RWST 8

Both H

No Yes > 0.10 No Not Repaired 02-CH-MOV-2115D Charging Charging Pump Supply from RWST 8

Both H

No Yes > 0.10 No Not Repaired 02-CH-MOV-2289A Charging Main Charging Header Isolation Valve 3

Close L

No Yes > 0.10 No Not Repaired 02-CH-MOV-2289B Charging Main Charging Header Isolation Valve 3

Close L

No Yes > 0.10 No Not Repaired 02-RH-MOV-2720A Residual Heat Removal (RHR)

RHR Outlet Isolation to Accumulator Discharge Line 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

02-RH-MOV-2720B Residual Heat Removal (RHR)

RHR Outlet Isolation to Accumulator Discharge Line 8

Open M

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

02-SI-MOV-2842 Safety Injection (SI) High Head SI from Charging Header to RCS Cold Legs 4

Both H

No Yes > 0.10 No Not Repaired 02-SI-MOV-2864A Safety Injection (SI) Low Head SI Pump Cold Leg Discharge Stop Valve 10 Both L

No Yes > 0.10 No Not Repaired 02-SI-MOV-2864B Safety Injection (SI) Low Head SI Pump Cold Leg Discharge Stop Valve 10 Both L

No Yes > 0.10 No Not Repaired 02-SI-MOV-2867C Safety Injection (SI) High Head SI to RCS Cold Legs 3

Both H

No Yes > 0.10 No Not Repaired 02-SI-MOV-2867D Safety Injection (SI) High Head SI to RCS Cold Legs 3

Both H

No Yes > 0.10 No Not Repaired 02-SI-MOV-2890A Safety Injection (SI) Low Head SI Pump Hot Leg Discharge Stop Valve 8

Both L

No No No Not Repaired Valve size is 10 X 8 X 10.

Wednesday, February 21, 2018 Page 6 of 71

Owner/Operator PLANT Dkt #

02-SI-MOV-2890B Safety Injection (SI) Low Head SI Pump Hot Leg Discharge Stop Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

02-SI-MOV-2890C Safety Injection (SI) Low Head SI Pump Cold Leg Discharge Stop Valve 8

Both L

No Yes > 0.10 No Not Repaired Valve size is 10 X 8 X 10.

Total # of Valves 14 Total # of Valves Repaired 0

Total # of Valves Not Repaired 14 Total # High Risk Valves 5

Total # Med Risk Valves 2

Total # Low Risk Valves 7

Total Thread Fric > 0.10 13 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 44 Total # of Valves Repaired 1

Total # of Valves Not Repaired 43 Total # High Risk Valves 11 Total # Med Risk Valves 10 Total # Low Risk Valves 23 Total Thread Fric > 0.10 39 Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

DTE Energy Fermi 2 341 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Duke Energy Power Company, LLC Wednesday, February 21, 2018 Page 7 of 71

Owner/Operator PLANT Dkt #

Brunswick 1 325 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1B32-F031A Reactor Recirc Reactor Recirc Pump 1A Discharge Valve 24 Close L

Yes Yes > 0.10 No Not Repaired Valve size = 24 X 28. Perform diagnostic testing and stem rotation checks with contingency repairs every other refueling outage beginning B1R22 (2018) 1B32-F031B Reactor Recirc Reactor Recirc Pump 1B Discharge Valve 24 Close L

Yes Yes > 0.10 No Not Repaired Valve size = 24 X 28. Perform diagnostic testing and stem rotation checks with contingency repairs every other refueling outage beginning B1R22 (2018) 1B32-F032A Reactor Recirc Reactor Recirc Pump 1A Discharge Bypass Valve 4

Close L

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018) 1B32-F032B Reactor Recirc Reactor Recirc Pump 1B Discharge Bypass Valve 4

Close L

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018) 1-E41-F002 High Pressure Coolant Injection (HPCI)

HPCI Turbine Steam Supply Inboard Isolation Valve 10 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018) 1-E41-F003 High Pressure Coolant Injection (HPCI)

HPCI Turbine Steam Supply Outboard Isolation Valve 10 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018) 1-E41-F006 High Pressure Coolant Injection (HPCI)

HPCI Injection Valve 14 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018) 1-E51-F008 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Supply Line Outboard Isolation Valve 3

Both M

Yes Yes > 0.10 No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018). Repair valve committed date B1R23 (2020) 1-E51-F013 Reactor Core Isolation Cooling (RCIC)

RCIC Injection Valve 4

Both M

Yes Yes > 0.10 No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R22 (2018). Repair valve committed date B1R23 (2020) 1-G31-F001 Reactor Water Cleanup (RWCU)

RWCU Inlet Line Inboard Isolation Valve 6

Close M

No No No Repaired 1-G31-F004 Reactor Water Cleanup (RWCU)

RWCU Inlet Line Outboard Isolation Valve 6

Close M

Yes Yes > 0.10 No Not Repaired Perform stem rotation check with contigency repair. Committed Date B1R22 (2018). Perform diagnostic testing and stem rotation check with contigency repair. Committed date B1R23 (2020) Repair/replace valve committed date B1R24 (2022). This valve is limit seated so the risk of breaking the pin during normal operation is low.

Wednesday, February 21, 2018 Page 8 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 11 Total # of Valves Repaired 1

Total # of Valves Not Repaired 10 Total # High Risk Valves 0

Total # Med Risk Valves 7

Total # Low Risk Valves 4

Total Thread Fric > 0.10 5

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 10 Total # of Valves N/A 0

Brunswick 2 324 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2B32-F031A Reactor Recirc Reactor Recirc Pump 2A Discharge Valve 24 Close L

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size = 24 X 28. Perform diagnostic testing and stem rotation checks with contingency repairs every other refueling outage beginning B2R24 (2019) 2B32-F031B Reactor Recirc Reactor Recirc Pump 2B Discharge Valve 24 Close L

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size = 24 X 28. Perform diagnostic testing and stem rotation checks with contingency repairs every other refueling outage beginning B2R24 (2019) 2B32-F032A Reactor Recirc Reactor Recirc Pump 2A Discharge Bypass Valve 4

Close L

No No Yes < or

= 5 deg.

Not Repaired 2B32-F032B Reactor Recirc Reactor Recirc Pump 2B Discharge Bypass Valve 4

Close L

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R24 (2019) 2-E41-F002 High Pressure Coolant Injection (HPCI)

HPCI Turbine Steam Supply Inboard Isolation Valve 10 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R24 (2019) 2-E41-F003 High Pressure Coolant Injection (HPCI)

HPCI Turbine Steam Supply Outboard Isolation Valve 10 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R24 (2019) 2-E41-F006 High Pressure Coolant Injection (HPCI)

HPCI Injection Valve 14 Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contigency repairs. Committed date B1R24 (2019) 2-E51-F008 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Supply Line Outboard Isolation Valve 3

Both M

No N/A Valve is not applicable to Part 21 due to T-Head Design 2-E51-F013 Reactor Core Isolation Cooling (RCIC)

RCIC Injection Valve 4

Both M

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair valve committed date B1R24 (2019) 2-G31-F001 Reactor Water Cleanup (RWCU)

RWCU Inlet Line Inboard Isolation Valve 6

Close M

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair valve committed date B1R25 (2021) 2-G31-F004 Reactor Water Cleanup (RWCU)

RWCU Inlet Line Outboard Isolation Valve 6

Close M

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Perform diagnostic testing and stem rotation check with contigency repair. Committed date B1R24 (2019)

Repair/replace valve committed date B1R26 (2023). This valve is limit seated so the risk of breaking the pin during normal operation is low.

Wednesday, February 21, 2018 Page 9 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 11 Total # of Valves Repaired 0

Total # of Valves Not Repaired 10 Total # High Risk Valves 0

Total # Med Risk Valves 7

Total # Low Risk Valves 4

Total Thread Fric > 0.10 5

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 9

Total # of Valves N/A 1

Catawba 1 413 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1BB008A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 1BB010B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 1BB019A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 1BB021B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 1BB056A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 1BB057B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 1BB060A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 1BB061B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 1CA038A CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1CA042B CA Motor Driven Auxiliary Feedwater Pump B to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1CA046B CA Motor Driven Auxiliary Feedwater Pump B to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1CA050A CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired Wednesday, February 21, 2018 Page 10 of 71

Owner/Operator PLANT Dkt #

1CA054B CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1CA058A CA Motor Driven Auxiliary Feedwater Pump A to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1CA062A CA Motor Driven Auxiliary Feedwater Pump A to Steam Generator Isolation Valve 4

Close L

Yes Yes < or =

0.10 No Not Repaired Repair valve committed date C1R24 (Fall 2018) 1CA066B CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 1SV025B SV Steam Generator PORV Block Valve 6

Close L

Yes No No Not Repaired Repair valve committed date C1R24 (Fall 2018).

1SV026B SV Steam Generator PORV Block Valve 6

Close L

No No No Repaired 1SV027A SV Steam Generator PORV Block Valve 6

Close L

Yes No No Not Repaired Repair valve committed date C1R24 (Fall 2018) 1SV028A SV Steam Generator PORV Block Valve 6

Close L

No No No Repaired Total # of Valves 20 Total # of Valves Repaired 17 Total # of Valves Not Repaired 3

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 20 Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 3

Total # of Valves N/A 0

Catawba 2 414 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2BB008A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 2BB010B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 2BB019A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 2BB021B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired Wednesday, February 21, 2018 Page 11 of 71

Owner/Operator PLANT Dkt #

2BB056A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

No No No Repaired 2BB057B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 2BB060A BB Steam Generator Blowdown Containment Isolation Inside Valve 4

Close L

Yes Yes < or =

0.10 No Not Repaired Repair valve committed date C2R22 (Spring 2018) 2BB061B BB Steam Generator Blowdown Containment Isolation Outside Valve 4

Close L

No No No Repaired 2CA038A CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

Yes Yes < or =

0.10 No Not Repaired Repair valve committed dateC2R22 (Spring 2018) 2CA042B CA Motor Driven Auxiliary Feedwater Pump B to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA046B CA Motor Driven Auxiliary Feedwater Pump B to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA050A CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA054B CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA058A CA Motor Driven Auxiliary Feedwater Pump A to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA062A CA Motor Driven Auxiliary Feedwater Pump A to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2CA066B CA Turbine Driven Auxiliary Feedwater Pump to Steam Generator Isolation Valve 4

Close L

No No No Repaired 2SV025B SV Steam Generator PORV Block Valve 6

Close L

Yes No No Not Repaired Repair valve committed date C2R22 (Spring 2018).

2SV026B SV Steam Generator PORV Block Valve 6

Close L

No No No Repaired 2SV027A SV Steam Generator PORV Block Valve 6

Close L

Yes No No Not Repaired Repair valve committed date C2R22 (Spring 2018)

Wednesday, February 21, 2018 Page 12 of 71

Owner/Operator PLANT Dkt #

2SV028A SV Steam Generator PORV Block Valve 6

Close L

No No No Repaired Total # of Valves 20 Total # of Valves Repaired 16 Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 20 Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 4

Total # of Valves N/A 0

Harris 1 400 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

McGuire 1 369 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

McGuire 2 370 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Wednesday, February 21, 2018 Page 13 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Oconee 1 269 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1FDW-103 FDW Steam Generator Shell Drain Block Valve 4

Close L

No No No Repaired 1FDW-104 FDW Steam Generator Shell Drain Block Valve 4

Close L

No No No Repaired 1SF-97 SF Spent Fuel Pool to RC Make Up System Block Inside Containment Isolation Valve 3

Both H

No No No Repaired Total # of Valves 3

Total # of Valves Repaired 3

Total # of Valves Not Repaired 0

Total # High Risk Valves 1

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Oconee 2 270 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2FDW-103 FDW Steam Generator Shell Drain Block Valve 4

Close L

No No No Repaired 2SF-97 SF Spent Fuel Pool to RC Make Up System Block Inside Containment Isolation Valve 3

Both H

No No No Repaired Total # of Valves 2

Total # of Valves Repaired 2

Total # of Valves Not Repaired 0

Total # High Risk Valves 1

Total # Med Risk Valves 0

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Oconee 3 287 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 14 of 71

Owner/Operator PLANT Dkt #

3FDW-103 FDW Steam Generator Shell Drain Block Valve 4

Close L

No No No Repaired 3FDW-104 FDW Steam Generator Shell Drain Block Valve 4

Close L

No No No Repaired 3SF-97 SF Spent Fuel Pool to RC Make Up System Block Inside Containment Isolation Valve 3

Both H

No No No Repaired Total # of Valves 3

Total # of Valves Repaired 3

Total # of Valves Not Repaired 0

Total # High Risk Valves 1

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Robinson 2 261 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments AFW-V2-14A AFW SDAFW Pump FW Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

Replace valve with different design to resolve Flowserve Part 21 issued 2/25/2013 and updated 7/11/2017. Committed date R2R31 (2018).

AFW-V2-14B AFW SDAFW Pump FW Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

Replace valve with different design to resolve Flowserve Part 21 issued 2/25/2013 and updated 7/11/2017. Committed date R2R31 (2018).

AFW-V2-14C AFW SDAFW Pump FW Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

Replace valve with different design to resolve Flowserve Part 21 issued 2/25/2013 and updated 7/11/2017. Committed date R2R31 (2018).

AFW-V2-16A AFW AFW Header Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

AFW-V2-16B AFW AFW Header Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

AFW-V2-16C AFW AFW Header Discharge to Steam Generator 4

Both M

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is 12/31/2018.

CC-716B CC Cooling Water Inlet Valve 6

Close L

No No No Repaired Wednesday, February 21, 2018 Page 15 of 71

Owner/Operator PLANT Dkt #

CC-730 CC Bearing Cooling Water Inlet Valve 6

Close L

Yes No No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018)

CVC-381 CVC RCP Seal Water Return 3

Close L

No No Yes < or

= 10 deg.

Repaired MS-V1-8A MS Steam Generator Steam Supply to Steam Driven AFW Pump 2

Both M

No No No Repaired MS-V1-8B MS Steam Generator Steam Supply to Steam Driven AFW Pump 2

Both M

No No No Repaired MS-V1-8C MS Steam Generator Steam Supply to Steam Driven AFW Pump 2

Both M

No No No Repaired RHR-752A RHR RHR Pump Suction 14 Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R33 (2022)

RHR-752B RHR RHR Pump Suction 14 Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R33 (2022)

SI-860A SI CV Sump Recirc Suction 14 Both H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair valve committed date R2R31 (2018)

SI-860B SI CV Sump Recirc Suction 14 Both H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R32 (2020)

SI-861A SI CV Sump Recirc Suction 14 Both H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R32 (2020)

SI-861B SI CV Sump Recirc Suction 14 Both H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R32 (2020)

SI-862A SI RHR Loop RWST Isolation Valve 14 Close H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair valve committed date R2R31 (2018)

SI-862B SI RHR Loop RWST Isolation Valve 14 Close H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair valve committed date R2R31 (2018)

SI-864A SI RWST Discharge 16 Close H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair valve committed date R2R31 (2018)

SI-864B SI RWST Discharge 16 Close H

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair valve committed date R2R31 (2018)

Wednesday, February 21, 2018 Page 16 of 71

Owner/Operator PLANT Dkt #

SI-869 SI Loops "B" and "C" Hot Leg Injection Shutoff 3

Both L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Replace valve with a different valve design to resolve Flowserve Part 21 issued 2/25/2013 and updated 7/11/2017.

Commitment date is R2R31 (2018)

SI-878A SI SI Pump Discharge Header Cross Connect Valve 4

Close M

Yes Yes < or =

0.10 No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R32 (2020)

SI-878B SI SI Pump Discharge Header Cross Connect Valve 4

Close M

Yes Yes > 0.10 No Not Repaired Perform stem rotation check in accordance with TP16-1-112r4 with contingency repair. Committed date is R2R31 (2018).

Repair valve committed date R2R32 (2020)

Total # of Valves 25 Total # of Valves Repaired 5

Total # of Valves Not Repaired 20 Total # High Risk Valves 8

Total # Med Risk Valves 11 Total # Low Risk Valves 6

Total Thread Fric > 0.10 12 Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 20 Total # of Valves N/A 0

Total # of Valves 95 Total # of Valves Repaired 47 Total # of Valves Not Repaired 47 Total # High Risk Valves 11 Total # Med Risk Valves 25 Total # Low Risk Valves 59 Total Thread Fric > 0.10 22 Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 46 Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 1

Energy Northwest Columbia 397 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments HPCS-V-1 High Pressure Core Spray (HPCS)

HPCS-P-1 Suction from Condensate Storage Tank 14 Close H

No No Yes < or

= 5 deg.

Repaired HPCS-V-12 High Pressure Core Spray (HPCS)

HPCS-P-1 Minimum Flow Valve 4

Both H

Yes No Yes < or

= 5 deg.

Repaired HPCS-V-15 High Pressure Core Spray (HPCS)

HPCS-P-1 Suction From the Suppression Pool 18 Both H

Yes No Yes < or

= 5 deg.

Repaired HPCS-V-4 High Pressure Core Spray (HPCS)

HPCS-P-1 Discharge to Reactor Pressure Vessel (Injection Valve) 12 Both H

Yes No Yes < or

= 5 deg.

Repaired Wednesday, February 21, 2018 Page 17 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 4

Total # of Valves Repaired 4

Total # of Valves Not Repaired 0

Total # High Risk Valves 4

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 3

Total # of Valves N/A 0

Total # of Valves 4

Total # of Valves Repaired 4

Total # of Valves Not Repaired 0

Total # High Risk Valves 4

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 3

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Entergy Nuclear Operations, Inc.

Arkansas Nuclear 313 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments CV-1009 Reactor Coolant System (RCS)

Pressurizer Spray Isolation Valve 2

None L

N/

A No Yes < 20 deg.

Not Repaired Valve size is 2.5. Susceptibility has not been determined CV-1213 Reactor Coolant System (RCS)

Letdown Heat Exchanger Inlet Valve 2

None L

Yes No Yes < 20 deg.

Repaired Valve size is 2.5.

CV-1214 MU Letdown Heat Exchanger Inlet Isolation Valve 2

Close L

N/

A No Yes < 20 deg.

Not Repaired Valve size is 2.5. Susceptibility has not been determined CV-1215 Reactor Coolant System (RCS)

Letdown Heat Exchanger Inlet Valve 2

None L

Yes No Yes < 20 deg.

Repaired Valve size is 2.5.

CV-1216 MU Letdown Heat Exchanger Inlet Isolation Valve 2

Close L

N/

A No Yes < 20 deg.

Not Repaired Valve size is 2.5.

CV-1221 MU RCS LD RB Isolation 2

Close L

Yes No Yes < 20 deg.

Repaired Valve size is 2.5.

CV-1233 MU RCS Makeup Block Valve 2

Close L

Yes No Yes < 20 deg.

Repaired Valve size is 2.5.

CV-1234 MU RCS Makeup Block Valve 2

Close L

Yes No Yes < 20 deg.

Repaired Valve size is 2.5.

Wednesday, February 21, 2018 Page 18 of 71

Owner/Operator PLANT Dkt #

CV-2215 ICW ICW to LD & RB Coolers 8

Close L

No No Yes < 20 deg.

Not Repaired CV-2220 ICW ICW to LD & CRD Coolers 8

Close L

No No Yes < 20 deg.

Not Repaired CV-2221 ICW ICW to CRD Cooler Supply 8

Close L

No No Yes < 20 deg.

Not Repaired CV-2235 ICW ICW to LD & CRD Coolers 3

Close L

Yes No Yes < 20 deg.

Repaired CV-2625 Feedwater (FW)

Main Feedwater Block Valve 18 Close L

Yes No Yes < 20 deg.

Not Repaired Repair committed date = Spring 2018 CV-2630 Feedwater (FW)

Main Feedwater Isolation Valve 18 Close L

Yes No Yes < 20 deg.

Not Repaired Repair committed date = Spring 2018 CV-2675 Feedwater (FW)

Main Feedwater Block Valve 18 Close L

Yes No Yes < 20 deg.

Not Repaired Repair committed date = Spring 2018 CV-2680 Feedwater (FW)

Main Feedwater Isolation Valve 18 Close L

Yes No Yes < 20 deg.

Not Repaired Repair committed date = Spring 2018 CV-2827 Feedwater (FW)

FW Crossover Isolation Valve 14 None L

Yes No Yes < 20 deg.

Not Repaired Repair committed date = Spring 2018 Total # of Valves 17 Total # of Valves Repaired 6

Total # of Valves Not Repaired 11 Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 17 Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 11 Total # of Valves N/A 0

Arkansas Nuclear 368 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2CV-4653 Reactor Coolant System (RCS)

Pressurizer Spray Isolation Valve 3

None L

Yes N/A No Not Repaired 2CV-4654 Reactor Coolant System (RCS)

Pressurizer Spray Isolation Valve 3

None L

Yes N/A No Not Repaired 2CV-4655 Reactor Coolant System (RCS)

Pressurizer Spray Isolation Valve 3

None L

Yes N/A No Not Repaired Wednesday, February 21, 2018 Page 19 of 71

Owner/Operator PLANT Dkt #

2CV-4656 Reactor Coolant System (RCS)

Pressurizer Spray Isolation Valve 3

None L

Yes N/A No Not Repaired Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 4

Total # of Valves N/A 0

Grand Gulf 1 416 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1B33F023A Recirc Recirc Pump A Suction Valve 24 None N/

A Yes No Yes < or

= 5 deg.

Not Repaired 1B33F023B Recirc Recirc Pump B Suction Valve 24 None N/

A Yes No Yes < or

= 5 deg.

Not Repaired 1B33F067A Recirc Recirc Pump A Discharge Valve 24 None N/

A No N/A No Repaired Repaired in 2004 1B33F067B Recirc Recirc Pump B Discharge Valve 24 None N/

A No N/A No Repaired Repaired in 2004 Total # of Valves 4

Total # of Valves Repaired 2

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Indian Point 2 247 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1802A Safety Injection (SI) 21 Recirculation Pump Discharge Stop Valve 10 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 1802B Safety Injection (SI) 22 Recirculation Pump Discharge Stop Valve 10 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 744 Residual Heat Removal (RHR)

RHR Pumps Discharge to Residual Heat Exchangers Isolation Valve 10 Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Wednesday, February 21, 2018 Page 20 of 71

Owner/Operator PLANT Dkt #

746 Residual Heat Removal (RHR)

RHR Hx-22 Outlet Isolation Stop Valve 8

Both H

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 747 Residual Heat Removal (RHR)

RHR Hx-21 Outlet Isolation Stop Valve 8

Both H

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 769 Component Cooling Water (CCW)

RCPSTRV Support CCW Inlet Isolation Valve 6

Close L

No Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired 784 Component Cooling Water (CCW)

RCPS Bearing Water Return Isolation Valve 6

Close L

No Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired 797 Component Cooling Water (CCW)

RCPS-RV Support CCW Inlet Isolation Valve 6

Close L

No Yes < or =

0.10 No Not Repaired 850A Safety Injection (SI) 21 Safety Injection Pump Discharge Stop Valve 4

Close L

No No No Not Repaired 850B Safety Injection (SI) 23 Safety Injection Pump Discharge Stop Valve 4

Close L

No No Yes < or

= 10 deg.

Not Repaired 851A Safety Injection (SI) 22 SI Pump Tie Valve to Discharge of 21 SI Pump 4

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Repaired 851B Safety Injection (SI) 22 SI Pump Tie Valve to Discharge of 23 SI Pump 4

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 882 Safety Injection (SI) RHR Pumps Suction From RWST 10 Close M

No Yes < or =

0.10 No Not Repaired 885A Safety Injection (SI) RHR Pump Suction From Containment Sump 12 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Repaired 885B Safety Injection (SI) RHR Pump Suction From Containment Sump 12 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Repaired 888A Safety Injection (SI) SI Pumps Suction From Residual Heat Exchanger 21 & 22 4

Both H

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 888B Safety Injection (SI) SI Pumps Suction From Residual Heat Exchanger 21 & 22 4

Both H

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 894A Safety Injection (SI) Accumulator Tank 21 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Wednesday, February 21, 2018 Page 21 of 71

Owner/Operator PLANT Dkt #

894B Safety Injection (SI) Accumulator Tank 22 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 894C Safety Injection (SI) Accumulator Tank 23 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired 894D Safety Injection (SI) Accumulator Tank 24 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired FCV-625 Component Cooling Water (CCW)

RCP Thermal Barrier CCW Return Header Flow 3

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Repaired Total # of Valves 22 Total # of Valves Repaired 4

Total # of Valves Not Repaired 18 Total # High Risk Valves 4

Total # Med Risk Valves 5

Total # Low Risk Valves 13 Total Thread Fric > 0.10 16 Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 0

Total # of Valves N/A 0

Indian Point 3 286 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments AC-MOV-1802A Safety Injection (SI) Recirc Pump Discharge Isolation Valve 10 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-1802B Safety Injection (SI) Recirc Pump Discharge Isolation Valve 10 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-1835A Safety Injection (SI) BIT Outlet Isolation Valve 4

Both L

Yes Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-1835B Safety Injection (SI) BIT Outlet Isolation Valve 4

Both L

No Yes < or =

0.10 No Not Repaired AC-MOV-1852A Safety Injection (SI) Boron Injection Tank Inlet Stop Valve 4

None L

No Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-1852B Safety Injection (SI) Boron Injection Tank Inlet Stop Valve 4

None L

No Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-1869A Safety Injection (SI) 32 RHR Outlet to SI/RHR Miniflow Isolation Valve 6

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-1869B Safety Injection (SI) 31 RHR Outlet to SI/RHR Miniflow Isolation Valve 6

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Wednesday, February 21, 2018 Page 22 of 71

Owner/Operator PLANT Dkt #

AC-MOV-743 Residual Heat Removal (RHR)

RHR Loop Miniflow Test Line Stop Valve 3

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-744 Residual Heat Removal (RHR)

RHR Pumps Discharge Isolation Valve 10 Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-745A Residual Heat Removal (RHR) 32 RHR Heat Exchabger Inlet Isolation Valve 6

Close L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-745B Residual Heat Removal (RHR) 32 RHR Heat Exchabger Inlet Isolation Valve 6

Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-851A Safety Injection (SI) 32 SI Pump Discharge Isolation Valve 4

Both L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-851B Safety Injection (SI) 32 SI Pump Discharge Isolation Valve 4

Both L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-856A Containment Spray Containment Spray Pump #31 Discharge Stop Valve 6

Both L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-856B Containment Spray Containment Spray Pump #32 Discharge Stop Valve 6

Both L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-882 Safety Injection (SI) RHR Pumps RWST Suction Isolation Valve 10 Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-883 Safety Injection (SI) RHR Pump Recirc Line to RWST Stop Valve 8

Open L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-885A Safety Injection (SI) Containment Sump RHR Suction Isolation Valve 14 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-885B Safety Injection (SI) Containment Sump RHR Suction Isolation Valve 14 Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-888A Safety Injection (SI) Low Head to High Head SI Recirc Stop Valve 4

Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-888B Safety Injection (SI) Low Head to High Head SI Recirc Stop Valve 4

Both M

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-889A CSS 32 RHR Heat Exchanger Outlet to Spray Header Stop Valve 6

Open L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Wednesday, February 21, 2018 Page 23 of 71

Owner/Operator PLANT Dkt #

AC-MOV-889B CSS 31 RHR Heat Exchanger Outlet to Spray Header Stop Valve 6

Open L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Repair committed date = Spring 2019 AC-MOV-894A Safety Injection (SI) Accumulator Tank 31 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-894B Safety Injection (SI) Accumulator Tank 32 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-894C Safety Injection (SI) Accumulator Tank 33 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired AC-MOV-894D Safety Injection (SI) Accumulator Tank 34 Discharge Stop Valve 8

None L

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Total # of Valves 28 Total # of Valves Repaired 0

Total # of Valves Not Repaired 28 Total # High Risk Valves 0

Total # Med Risk Valves 6

Total # Low Risk Valves 22 Total Thread Fric > 0.10 24 Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 7

Total # of Valves N/A 0

Palisades 255 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Pilgrim 1 293 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MO-1001-29B Residual Heat Removal (RHR)

LPCI Loop B Injection Valve #2 18 Both H

Yes Yes > 0.10 No Not Repaired Repair committed date = F/O 2018 MO-202-4A Recirc Reactor Recirc Pump A Suction Valve 24 None N/

A N/

A N/A N/A Not Repaired Valve size is 28 X 24 X 28 Wednesday, February 21, 2018 Page 24 of 71

Owner/Operator PLANT Dkt #

MO-202-4B Recirc Reactor Recirc Pump B Suction Valve 24 None N/

A N/

A N/A N/A Not Repaired Valve size is 28 X 24 X 28 MO-202-5A Recirc Reactor Recirc Pump A Discharge Valve 24 Close H

No Yes > 0.10 No Not Repaired Valve size is 28 X 24 X 28 MO-202-5B Recirc Reactor Recirc Pump B Discharge Valve 24 Close H

No Yes > 0.10 No Not Repaired Valve size is 28 X 24 X 28 Total # of Valves 5

Total # of Valves Repaired 0

Total # of Valves Not Repaired 5

Total # High Risk Valves 3

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 3

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 1

Total # of Valves N/A 0

River Bend 1 458 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments B33-MOVF023A Recirc Reactor Recirc Pump A Discharge Header Loop A Isolation Valve Oper 24 None N/

A Yes No No Not Repaired B33-MOVF023B Recirc Reactor Recirc Pump B Discharge Header Loop B Isolation Valve Oper 24 None N/

A Yes No No Not Repaired B33-MOVF067A Recirc Reactor recirc Pump A Suction Header Loop A Isolation Valve Oper 24 None N/

A No Yes < or =

0.10 No Repaired Repaired in 2007 B33-MOVF067B Recirc Reactor recirc Pump B Suction Header Loop B Isolation Valve Oper 24 None N/

A No Yes < or =

0.10 No Repaired Repaired in 2007 Total # of Valves 4

Total # of Valves Repaired 2

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 2

Total # of Valves N/A 0

Waterford 3 382 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments SI MVAAA407A Safety Injection (SI) RC Loop 2 SDC Suction Outside Containment Isolation Valve 14 Open L

Yes No Yes < or

= 5 deg.

Not Repaired Repair committed date = Jan/Feb 2019 Wednesday, February 21, 2018 Page 25 of 71

Owner/Operator PLANT Dkt #

SI MVAAA407B Safety Injection (SI) RC Loop 1 SDC Suction Outside Containment Isolation Valve 14 Open L

Yes No Yes < or

= 5 deg.

Not Repaired Repair committed date = Jan/Feb 2019 Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Total # of Valves 86 Total # of Valves Repaired 14 Total # of Valves Not Repaired 72 Total # High Risk Valves 7

Total # Med Risk Valves 11 Total # Low Risk Valves 58 Total Thread Fric > 0.10 43 Total Thread Fric < or = 0.10 10 Total # Susceptible Valves 29 Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Exelon Generation Co., LLC Braidwood 1 456 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Braidwood 2 457 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 26 of 71

Owner/Operator PLANT Dkt #

Byron 1 454 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Byron 2 455 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Calvert Cliffs 1 317 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1MOV0403 Reactor Coolant Pressurizer PORV Blocking Valve 2

Both M

No N/A Valve size is 2.5. Valve is not applicable to Part 21 due to T-Head Design 1MOV0405 Reactor Coolant Pressurizer PORV Blocking Valve 2

Both M

No N/A Valve size is 2.5. Valve is not applicable to Part 21 due to T-Head Design 1MOV2080 Instrument Air Instrument Air Containment Isolation Valve 2

Both L

No N/A Valve is not applicable to Part 21 due to T-Head Design Total # of Valves 3

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 2

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 3

Wednesday, February 21, 2018 Page 27 of 71

Owner/Operator PLANT Dkt #

Calvert Cliffs 2 318 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2MOV0403 Reactor Coolant Pressurizer PORV Blocking Valve 2

Both M

No N/A Valve size is 2.5. Valve is not applicable to Part 21 due to T-Head Design 2MOV0405 Reactor Coolant Pressurizer PORV Blocking Valve 2

Both M

No N/A Valve size is 2.5. Valve is not applicable to Part 21 due to T-Head Design 2MOV2080 Instrument Air Instrument Air Containment Isolation Valve 2

Both L

No N/A Valve is not applicable to Part 21 due to T-Head Design Total # of Valves 3

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 2

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 3

Clinton 1 461 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Dresden 2 237 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-0205-2-4 Nuclear Boiler Reactor Head Spray Outboard Isolation Valve 3

Close L

No N/A Valve is not applicable to Part 21 due to T-Head Design 2-1001-01A Residual Heat Removal Shutdown Cooling Suction Inboard Containment Isolation Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 2-1001-01B Residual Heat Removal Shutdown Cooling Suction Inboard Containment Isolation Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2009 Wednesday, February 21, 2018 Page 28 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 3

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 3

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 1

Dresden 3 249 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 3-0205-2-4 Nuclear Boiler Reactor Head Spray Outboard Isolation Valve 2

Close L

No N/A Valve size is 2.5. Valve is not applicable to Part 21 due to T-Head Design 3-1201-1 Reactor Water Cleanup (RWCU)

RWCU Inlet Containment Isolation Valve 8

Close M

No No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016 3-1201-1-1A Reactor Water Cleanup (RWCU)

RWCU Inlet Bypass Containment Isolation Valve 2

Close M

No N/A Valve is not applicable to Part 21 due to T-Head Design 3-1201-2 Reactor Water Cleanup (RWCU)

RWCU Aux Pump Bypass 8

Close M

No No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2014 Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 3

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 2

FitzPatrick 333 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 02-2MOV-53A Reactor Recirculation Reactor Recirc Pump A Discharge 28 Close L

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2014. Repair valve committed date FPR25 (2022). Valve will also undergo stem rotation checks and diagnostic testing during FPR23 (2018) and FPR24 (2020).

02-2MOV-53B Reactor Recirculation Reactor Recirc Pump A Discharge 28 Close L

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2014. Repair valve committed date FPR25 (2022). Valve will also undergo stem rotation checks and diagnostic testing during FPR23 (2018) and FPR24 (2020).

10MOV-16A Residual Heat Removal (RHR)

RHR A Minimum Flow 4

Both L

No No No Not Repaired Last diagnostic test = 2010 10MOV-16B Residual Heat Removal (RHR)

RHR B Minimum Flow 4

Both L

No No No Not Repaired Last diagnostic test = 2010 Wednesday, February 21, 2018 Page 29 of 71

Owner/Operator PLANT Dkt #

10MOV-17 Residual Heat Removal (RHR)

RHR Shutdown Cooling Outboard Isolation Valve 20 Close M

No No No Not Repaired Last diagnostic test = 2014 10MOV-18 Residual Heat Removal (RHR)

RHR Shutdown Cooling Inboard Isolation Valve 20 Close M

No No No Not Repaired Last diagnostic test = 2017 10MOV-26A Residual Heat Removal (RHR)

RHR Train A Containment Spray 10 Both H

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2017. Repair valve committed date FPR23 (2018) 10MOV-26B Residual Heat Removal (RHR)

RHR Train B Containment Spray 10 Both H

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2014. Repair valve committed date FPR23 (2018) or will complete in a 2018 RHR work window.

10MOV-39B Residual Heat Removal (RHR)

RHR Train B Torus Cooling Isolation 16 Both H

No Yes < or =

0.10 No Not Repaired Last diagnostic test = 2013 12MOV-15 Reactor Water Cleanup (RWCU)

RWCU Supply Inboard 6

Close H

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2017. Repair valve committed date FPR23 (2018) 12MOV-69 Reactor Water Cleanup (RWCU)

RWCU Return Containment 4

Close L

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2012. Repair valve committed date FPR25 (2022). Valve will also undergo stem rotation checks and diagnostic testing during FPR23 (2018) and FPR24 (2020).

13MOV-15 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Supply Inboard Isolation Valve 3

Close H

No N/A Valve is not applicable to Part 21 due to T-Head Design 20MOV-82 Rad Waste Drywell Floor Drain Sump Isolation Valve 3

Close L

No N/A Valve is not applicable to Part 21 due to T-Head Design 20MOV-94 Rad Waste Drywell Equipment Drain Sump Isolation 3

Close L

No N/A Valve is not applicable to Part 21 due to T-Head Design 23MOV-15 High Pressure Coolant Injection (HPCI)

HPCI Steam Supply Isolation 10 Close H

No Yes < or =

0.10 No Not Repaired Last diagnostic test = 2014.

29MOV-74 Main Steam Main Steam Line Drain Inboard Isolation Valve 3

Close L

No N/A Valve is not applicable to Part 21 due to T-Head Design 29MOV-77 Main Steam Main Steam Line Drain Outboard Isolation Valve 3

Close L

No N/A Valve is not applicable to Part 21 due to T-Head Design Total # of Valves 17 Total # of Valves Repaired 0

Total # of Valves Not Repaired 12 Total # High Risk Valves 6

Total # Med Risk Valves 2

Total # Low Risk Valves 9

Total Thread Fric > 0.10 6

Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 6

Total # of Valves N/A 5

Wednesday, February 21, 2018 Page 30 of 71

Owner/Operator PLANT Dkt #

Ginna 244 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 515 Reactor Coolant System (RCS)

Pressurizer Pressurizer Relief Stop Valve 3

Both L

No N/A Valve is not applicable to Part 21 due to T-Head Design 516 Reactor Coolant System (RCS)

Pressurizer Pressurizer Relief Stop Valve 3

Both L

No N/A Valve is not applicable to Part 21 due to T-Head Design 704A Residual Heat Removal (RHR)

RHR Pump 1A Cross Connect 10 Close L

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2011. Repair valve committed date =

G1R42 (2020). Assuming no degradation is found, a high strength wedge pin will be used. If degraded, a full repair in accordance with TP16-1-112r4 will be performed.

704B Residual Heat Removal (RHR)

RHR Pump 1B Cross Connect 10 Close L

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2009. Repair valve committed date =

G1R42 (2020). Assuming no degradation is found, a high strength wedge pin will be used. If degraded, a full repair in accordance with TP16-1-112r4 will be performed.

841 Safety Injection (SI) Accumlator tank 1A Shutoff 10 Close M

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2014. Repair valve committed date =

G1R42 (2020). Assuming no degradation is found, a high strength wedge pin will be used. If degraded, a full repair in accordance with TP16-1-112r4 will be performed.

850A Residual Heat Removal (RHR)

Sump B to RHR Pumps 10 Both H

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 850B Residual Heat Removal (RHR)

Sump B to RHR Pumps 10 Both H

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 856 Residual Heat Removal (RHR)

RWST to RHR Pumps 10 Close M

No No No Not Repaired Last diagnostic test = 2011 857A Residual Heat Removal (RHR) 1A RHR Heat Exchanger to SI/CSP 6

Open L

No No No Not Repaired Last diagnostic test = 2014 857B Residual Heat Removal (RHR) 1B RHR Heat Exchanger to SI/CSP 6

Open M

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 857C Residual Heat Removal (RHR)

RHR Heat Exchanger to 1A Outlet 6

Open L

No No No Not Repaired Last diagnostic test = 2015 860A Containment Spray 1A CSP Discharge 6

Both L

No No No Not Repaired Last diagnostic test = 2014 Wednesday, February 21, 2018 Page 31 of 71

Owner/Operator PLANT Dkt #

860B Containment Spray 1A CSP Discharge 6

Both L

No No No Not Repaired Last diagnostic test = 2015 860C Containment Spray 1B CSP Discharge 6

Both L

No No No Not Repaired Last diagnostic test = 2015 860D Containment Spray 1B CSP Discharge 6

Both L

No No No Not Repaired Last diagnostic test = 2015 865 Safety Injection (SI) Accumlator tank 1B Shutoff 10 Close M

Yes Yes > 0.10 No Not Repaired Last diagnostic test = 2014. Repair valve committed date =

G1R42 (2020). Assuming no degradation is found, a high strength wedge pin will be used. If degraded, a full repair in accordance with TP16-1-112r4 will be performed.

Total # of Valves 16 Total # of Valves Repaired 0

Total # of Valves Not Repaired 14 Total # High Risk Valves 2

Total # Med Risk Valves 4

Total # Low Risk Valves 10 Total Thread Fric > 0.10 4

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 4

Total # of Valves N/A 2

LaSalle County 1 373 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1B21-F067A Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 1B21-F067B Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 1B21-F067C Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 1B21-F067D Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 1E22-F004 High Pressure Core Spray (HPCS)

HPCS Injection Isolation Valve 12 Both M

No N/A No Repaired Valve was repaired June 2017 1E22-F012 High Pressure Core Spray (HPCS)

HPCS Pump Min Flow 4

Both M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

1E22-F015 High Pressure Core Spray (HPCS)

HPCS Pump Suppression Pool Suction 18 Close L

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

Wednesday, February 21, 2018 Page 32 of 71

Owner/Operator PLANT Dkt #

1E51-F008 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Outboard Isolation Valve 4

Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

1E51-F013 Reactor Core Isolation Cooling (RCIC)

RCIC Injection Outboard Isolation Valve 6

Both L

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

1E51-F063 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Supply Inboard Isolation Valve 10 Close H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

1G33-F001 Reactor Water Cleanup (RWCU)

RWCU Inboard Isolation Valve 6

Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

1G33-F004 Reactor Water Cleanup (RWCU)

RWCU Outboard Isolation Valve 6

Close H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair valve committed date =

L1R17 (2018).

Total # of Valves 12 Total # of Valves Repaired 1

Total # of Valves Not Repaired 7

Total # High Risk Valves 2

Total # Med Risk Valves 4

Total # Low Risk Valves 6

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 7

Total # of Valves N/A 4

LaSalle County 2 374 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2B21-F067A Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 2B21-F067B Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 2B21-F067C Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 2B21-F067D Main Steam (MS)

Drains MS Drain Line Isolation Valve 1

Close L

No N/A Valve size is 1.5. Valve is not applicable to Part 21 due to T-Head Design 2E22-F004 High Pressure Core Spray (HPCS)

HPCS Injection Isolation Valve 12 Both M

No No No Repaired Valve was repaired February 2017 2E22-F012 High Pressure Core Spray (HPCS)

HPCS Pump Min Flow 4

Both M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2015. Repair valve committed date =

L2R17 (2019).

2E22-F015 High Pressure Core Spray (HPCS)

HPCS Pump Suppression Pool Suction 18 Close L

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2015. Repair valve committed date =

L2R17 (2019).

Wednesday, February 21, 2018 Page 33 of 71

Owner/Operator PLANT Dkt #

2E51-F008 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Outboard Isolation Valve 4

Close M

Yes No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017. Repair valve committed date =

L2R17 (2019).

2E51-F063 Reactor Core Isolation Cooling (RCIC)

RCIC Steam Supply Inboard Isolation Valve 10 Close H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2015. Repair valve committed date =

L2R17 (2019).

2G33-F001 Reactor Water Cleanup (RWCU)

RWCU Inboard Isolation Valve 6

Close M

Yes No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017. Repair valve committed date =

L2R17 (2019).

2G33-F004 Reactor Water Cleanup (RWCU)

RWCU Outboard Isolation Valve 6

Close H

Yes No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017. Repair valve committed date =

L2R17 (2019).

Total # of Valves 11 Total # of Valves Repaired 1

Total # of Valves Not Repaired 6

Total # High Risk Valves 2

Total # Med Risk Valves 4

Total # Low Risk Valves 5

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Total # of Valves N/A 4

Limerick 1 352 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments HV-052-1F001A Core Spray Core Spray Cooling Pump A Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2016 HV-052-1F001B Core Spray Core Spray Cooling Pump B Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2014 HV-052-1F001C Core Spray Core Spray Cooling Pump C Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2014 HV-052-1F001D Core Spray Core Spray Cooling Pump D Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2015 Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Limerick 2 353 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 34 of 71

Owner/Operator PLANT Dkt #

HV-052-2F001A Core Spray Core Spray Cooling Pump A Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2015 HV-052-2F001B Core Spray Core Spray Cooling Pump B Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2016 HV-052-2F001C Core Spray Core Spray Cooling Pump C Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2015 HV-052-2F001D Core Spray Core Spray Cooling Pump D Suction Valve 16 Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2016 Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Nine Mile Point 1 220 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Nine Mile Point 2 410 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 35 of 71

Owner/Operator PLANT Dkt #

Oyster Creek 219 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments V-14-0030 Isolation Condenser (IC)

IC NEO1A Inlet Isolation Valve 10 Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = OC1R27 (2018)

V-14-0031 Isolation Condenser (IC)

IC NEO1A Inlet Isolation Valve 10 Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2012. Repair committed date = OC1R27 (2018)

V-14-0032 Isolation Condenser (IC)

IC NEO1B Inlet Isolation Valve 10 Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2010. Repair committed date = OC1R27 (2018)

V-14-0033 Isolation Condenser (IC)

IC NEO1B Inlet Isolation Valve 10 Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = OC1R27 (2018)

V-14-0034 Isolation Condenser (IC)

IC NEO1A Outlet Isolation Valve 10 Both H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = OC1R27 (2018)

V-14-0035 Isolation Condenser (IC)

IC NEO1B Outlet Isolation Valve 10 Both H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = OC1R27 (2018)

Total # of Valves 6

Total # of Valves Repaired 0

Total # of Valves Not Repaired 6

Total # High Risk Valves 2

Total # Med Risk Valves 4

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Total # of Valves N/A 0

Peach Bottom 2 277 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MO-2-01A-074 Main Steam MSL Drain Inboard Isolation to Condenser 3

Close L

No No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2014.

MO-2-01A-077 Main Steam MSL Drain Outboard Isolation to Condenser 3

Close L

No No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2014.

MO-2-02-53A Reactor Recirc Reactor Recirc Pump A Discharge 24 Close L

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = P2R24 (2022). Valve will undergo stem rotation check and diagnostic testing during P2R22 (2018) and P2R23 (2020).

MO-2-02-53B Reactor Recirc Reactor Recirc Pump B Discharge 24 Close L

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = P2R24 (2022). Valve will undergo stem rotation check and diagnostic testing during P2R22 (2018) and P2R23 (2020).

Wednesday, February 21, 2018 Page 36 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Peach Bottom 3 278 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MO-3-01A-074 Main Steam MSL Drain Inboard Isolation to Condenser 3

Close L

No No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2013 MO-3-01A-077 Main Steam MSL Drain Outboard Isolation to Condenser 3

Close L

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 MO-3-02-53A Reactor Recirc Reactor Recirc Pump A Discharge 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017. Repair committed date = P2323 (2022). Valve will undergo stem rotation check and diagnostic testing during P3R22 (2019)

MO-3-02-53B Reactor Recirc Reactor Recirc Pump B Discharge 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017. Repair committed date = P2323 (2022). Valve will undergo stem rotation check and diagnostic testing during P3R22 (2019)

Total # of Valves 4

Total # of Valves Repaired 0

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Quad Cities 1 254 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1-1201-2 Reactor Water Cleanup (RWCU)

RWCU Inboard Isolation Valve 6

Close H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2015. Repair committed date = Q1R25 (2019) 1-1201-5 Reactor Water Cleanup (RWCU)

RWCU Outboard Isolation Valve 6

Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2017. Repair committed date = Q1R25 (2019)

Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 1

Total # Med Risk Valves 1

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 37 of 71

Owner/Operator PLANT Dkt #

Quad Cities 2 265 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-1201-2 Reactor Water Cleanup (RWCU)

RWCU Inboard Isolation Valve 6

Close H

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = Q2R24 (2018) 2-1201-5 Reactor Water Cleanup (RWCU)

RWCU Outboard Isolation Valve 6

Close M

Yes No Yes < or

= 10 deg.

Not Repaired Last diagnostic test = 2016. Repair committed date = Q2R24 (2018)

Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 1

Total # Med Risk Valves 1

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Three Mile Island 289 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments DH-V-3 Decay Heat Decay Heat Drop Line Containment Isolation Valve 12 Open H

No No Yes < or

= 5 deg.

Not Repaired Last diagnostic test = 2017 Total # of Valves 1

Total # of Valves Repaired 0

Total # of Valves Not Repaired 1

Total # High Risk Valves 1

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 96 Total # of Valves Repaired 2

Total # of Valves Not Repaired 70 Total # High Risk Valves 17 Total # Med Risk Valves 27 Total # Low Risk Valves 52 Total Thread Fric > 0.10 10 Total Thread Fric < or = 0.10 2

Total # Susceptible Valves 37 Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 24 FirstEnergy Nuclear Operating Co.

Beaver Valley 1 334 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MOV-1RW-113A River Water Diesel Generator (DG) Heat Exchanger Inlet River Water (RW) Supply Header 4

Open M

No No Yes < or

= 10 deg.

Not Repaired Wednesday, February 21, 2018 Page 38 of 71

Owner/Operator PLANT Dkt #

MOV-1RW-113B River Water Diesel Generator (DG) Heat Exchanger Inlet River Water (RW) Supply Header 4

Open M

No No Yes < or

= 10 deg.

Not Repaired MOV-1RW-113C River Water Diesel Generator (DG) Heat Exchanger Inlet River Water (RW) Supply Header 4

Open M

No No Yes < or

= 10 deg.

Not Repaired MOV-1RW-113D River Water Diesel Generator (DG) Heat Exchanger Inlet River Water (RW) Supply Header 4

Open M

No No Yes < or

= 10 deg.

Not Repaired MOV-1SI-863A Safety Injection Low Head Safety Injection (LHSI) to Charging Pumps Supply Valve 6

Open M

No No Yes < or

= 10 deg.

Not Repaired MOV-1SI-863B Safety Injection Low Head Safety Injection (LHSI) to Charging Pumps Supply Valve 6

Open M

No No Yes < or

= 10 deg.

Not Repaired MOV-1SI-890A Safety Injection Low Head Safety Injection (LHSI) to Reactor Coolant System (RCS) Hot Legs 8

Open L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10 MOV-1SI-890B Safety Injection Low Head Safety Injection (LHSI) to Reactor Coolant System (RCS) Hot Legs 8

Open L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Valve size is 10 X 8 X 10 MOV-1SI-890C Safety Injection Low Head Safety Injection (LHSI) to Reactor Coolant System (RCS) Cold Legs 8

Close H

No Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Valve size is 10 X 8 X 10 Total # of Valves 9

Total # of Valves Repaired 0

Total # of Valves Not Repaired 9

Total # High Risk Valves 1

Total # Med Risk Valves 6

Total # Low Risk Valves 2

Total Thread Fric > 0.10 3

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Beaver Valley 2 412 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 39 of 71

Owner/Operator PLANT Dkt #

Davis-Besse 1 346 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Perry 1 440 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 9

Total # of Valves Repaired 0

Total # of Valves Not Repaired 9

Total # High Risk Valves 1

Total # Med Risk Valves 6

Total # Low Risk Valves 2

Total Thread Fric > 0.10 3

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Florida Power & Light Co.

Duane Arnold 331 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MO4627 Reactor Recirc Reactor Recirc Pump 1P-201A Discharge Isolation Valve 22 Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform diagnostic testing and stem rotation check with contigency repair committed date RFO26 (2018). Repair valve committed date RFO27 (2020)

Wednesday, February 21, 2018 Page 40 of 71

Owner/Operator PLANT Dkt #

MO4628 Reactor Recirc Reactor Recirc Pump 1P-201B Discharge Isolation Valve 22 Close L

Yes Yes > 0.10 Yes < or

= 10 deg.

Not Repaired Perform diagnostic testing and stem rotation check with contigency repair committed dates RFO26 (2018) & RFO27 (2020). Repair valve committed date RFO28 (2022)

Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 2

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Point Beach 1 266 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments CC-00719 Component Cooling Containment Cooling Water Cont Return Isolation Valve 6

Close L

No No No Not Repaired RH-0070 Residual Heat Removal (RHR)

RCS Low Head SI Pump Suction From RCS Isolation Valve 10 Close M

No Yes < or =

0.10 No Not Repaired SI-00841A Safety Injection SI Accumulator to RCS Suction Isolation Valve 10 None L

No Yes < or =

0.10 No Not Repaired SI-00841B Safety Injection SI Accumulator to RCS Suction Isolation Valve 10 None L

No Yes < or =

0.10 No Not Repaired SI-00851A Safety Injection Sump A to Low Head SI Pump Suction Isolation Valve 10 Both M

No No No Not Repaired SI-00851B Safety Injection Sump A to Low Head SI Pump Suction Isolation Valve 10 Both M

No No No Not Repaired SI-00852A Safety Injection SI Core Deluge Isolation Valve 6

Both L

No No No Not Repaired SI-00852B Safety Injection SI Core Deluge Isolation Valve 6

Both L

No No No Not Repaired SI-00856A Safety Injection RWST to Low Head SI Pump Suction Isolation Valve 10 Close M

No No No Not Repaired SI-00856B Safety Injection RWST to Low Head SI Pump Suction Isolation Valve 10 Close M

No No No Not Repaired Wednesday, February 21, 2018 Page 41 of 71

Owner/Operator PLANT Dkt #

SI-00860A Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Both L

No No No Not Repaired SI-00860B Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Open L

No No No Not Repaired SI-00860C Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Both L

No No No Not Repaired SI-00860D Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Open L

No No No Not Repaired SI-00866A Safety Injection High Head SI Pump to Containment Isolation Valve 4

Both M

No No No Not Repaired SI-00866B Safety Injection High Head SI Pump to Containment Isolation Valve 4

Both M

No No No Not Repaired SI-00871A Safety Injection Low Head SI to Containment Spray Pump Suction Isolation Valve 6

Both M

No No No Not Repaired SI-00871B Safety Injection Low Head SI to Containment Spray Pump Suction Isolation Valve 6

Both M

No Yes < or =

0.10 No Not Repaired Total # of Valves 18 Total # of Valves Repaired 0

Total # of Valves Not Repaired 18 Total # High Risk Valves 0

Total # Med Risk Valves 9

Total # Low Risk Valves 9

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 0

Total # of Valves N/A 0

Point Beach 2 301 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments CC-00719 Component Cooling Containment Cooling Water Cont Return Isolation Valve 6

Close L

No No No Not Repaired RH-0070 Residual Heat Removal (RHR)

RCS Low Head SI Pump Suction From RCS Isolation Valve 10 Close M

No Yes < or =

0.10 No Not Repaired SI-00841A Safety Injection SI Accumulator to RCS Suction Isolation Valve 10 None L

No Yes < or =

0.10 No Not Repaired SI-00841B Safety Injection SI Accumulator to RCS Suction Isolation Valve 10 None L

No Yes < or =

0.10 No Not Repaired Wednesday, February 21, 2018 Page 42 of 71

Owner/Operator PLANT Dkt #

SI-00851A Safety Injection Sump A to Low Head SI Pump Suction Isolation Valve 10 Both M

No No No Not Repaired SI-00851B Safety Injection Sump A to Low Head SI Pump Suction Isolation Valve 10 Both M

No No No Not Repaired SI-00852A Safety Injection SI Core Deluge Isolation Valve 6

Both L

No No No Not Repaired SI-00852B Safety Injection SI Core Deluge Isolation Valve 6

Both L

No No No Not Repaired SI-00856A Safety Injection RWST to Low Head SI Pump Suction Isolation Valve 10 Close M

No No No Not Repaired SI-00856B Safety Injection RWST to Low Head SI Pump Suction Isolation Valve 10 Close M

No No No Not Repaired SI-00860A Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Both L

No No No Not Repaired SI-00860B Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Open L

No No No Not Repaired SI-00860C Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Both L

No No No Not Repaired SI-00860D Safety Injection Containment Spray Pump Discharge to Containment Isolation Valve 6

Open L

No No No Not Repaired SI-00866A Safety Injection High Head SI Pump to Containment Isolation Valve 4

Both M

No No No Not Repaired SI-00866B Safety Injection High Head SI Pump to Containment Isolation Valve 4

Both M

No No No Not Repaired SI-00871A Safety Injection Low Head SI to Containment Spray Pump Suction Isolation Valve 6

Both M

No Yes < or =

0.10 No Not Repaired SI-00871B Safety Injection Low Head SI to Containment Spray Pump Suction Isolation Valve 6

Both M

No No No Not Repaired Wednesday, February 21, 2018 Page 43 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 18 Total # of Valves Repaired 0

Total # of Valves Not Repaired 18 Total # High Risk Valves 0

Total # Med Risk Valves 9

Total # Low Risk Valves 9

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 0

Total # of Valves N/A 0

Seabrook 1 443 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

St. Lucie 1 335 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

St. Lucie 2 389 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-MV-08-12 Auxiliary Feedwater (AFW)

Steam Generator 2A Main Steam to AFW Pump 2C Flow Isolation Valve 4

Both H

No No No Not Repaired 2-MV-08-13 Auxiliary Feedwater (AFW)

Steam Generator 2B Main Steam to AFW Pump 2C Flow Isolation Valve 4

Both H

No No No Not Repaired Wednesday, February 21, 2018 Page 44 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 2

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Turkey Point 3 250 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MOV-3-716B Component Cooling Water (CCW)

Motor Operated Isoaltion Valve for CCW Supply to RCP Coolers 6

Close L

No No No Not Repaired MOV-3-730 Component Cooling Water (CCW)

Motor Operated Isoaltion Valve for CCW Return to RCP Coolers 6

Close L

No No No Not Repaired MOV-3-843A Safety Injection (SI) HHSI to Cold Leg MOV 4

Both H

No Yes < or =

0.10 No Not Repaired MOV-3-843B Safety Injection (SI) HHSI to Cold Leg MOV 4

Both H

No Yes < or =

0.10 No Not Repaired MOV-3-860A Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No Yes < or =

0.10 No Not Repaired MOV-3-860B Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No No No Not Repaired MOV-3-861A Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No No No Not Repaired MOV-3-861B Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No Yes < or =

0.10 No Not Repaired MOV-3-862A Residual Heat Removal (RHR)

Motor Operated Stop Valve on RHR Pumps Suction Header 14 Close M

No Yes < or =

0.10 No Not Repaired MOV-3-862B Residual Heat Removal (RHR)

Motor Operated Stop Valve on RHR Pumps Suction Header 14 Close M

No Yes < or =

0.10 No Not Repaired MOV-3-864A Safety Injection (SI) RWST Motor Operated Isolation Valve to SI & RHR Pumps 16 Close M

No No No Not Repaired MOV-3-864B Safety Injection (SI) RWST Motor Operated Isolation Valve to SI & RHR Pumps 16 Close M

No No No Not Repaired Wednesday, February 21, 2018 Page 45 of 71

Owner/Operator PLANT Dkt #

MOV-3-865A Safety Injection (SI) SI Accumulator A Discharge Motor Operated Valve 10 None L

No Yes < or =

0.10 No Not Repaired MOV-3-865B Safety Injection (SI) SI Accumulator B Discharge Motor Operated Valve 10 None L

No Yes < or =

0.10 No Not Repaired MOV-3-865C Safety Injection (SI) SI Accumulator C Discharge Motor Operated Valve 10 None L

No Yes < or =

0.10 No Not Repaired MOV-3-869 Safety Injection (SI) SI to Loop A & B Hot Leg Motor Operated Isolation Valve 3

Both L

No Yes < or =

0.10 No Not Repaired MOV-3-880A Containment Spray Containment Spray Pump Discharge Isolation Valve 6

Open M

No Yes < or =

0.10 No Not Repaired MOV-3-880B Containment Spray Containment Spray Pump Discharge Isolation Valve 6

Open M

No Yes < or =

0.10 No Not Repaired MOV-878A Safety Injection (SI) HHSI Header Sectionalizing Motor Operated Valve 4

Close L

No Yes < or =

0.10 No Not Repaired Licensee reported this valve to be associated with Unit 0 MOV-878B Safety Injection (SI) HHSI Header Sectionalizing Motor Operated Valve 4

Close L

No Yes < or =

0.10 No Not Repaired Licensee reported this valve to be associated with Unit 0 Total # of Valves 20 Total # of Valves Repaired 0

Total # of Valves Not Repaired 20 Total # High Risk Valves 2

Total # Med Risk Valves 10 Total # Low Risk Valves 8

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 14 Total # Susceptible Valves 0

Total # of Valves N/A 0

Turkey Point 4 251 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MOV-4-716B Component Cooling Water (CCW)

Motor Operated Isoaltion Valve for CCW Supply to RCP Coolers 6

Close L

No No No Not Repaired MOV-4-730 Component Cooling Water (CCW)

Motor Operated Isoaltion Valve for CCW Return to RCP Coolers 6

Close L

No No No Not Repaired MOV-4-843A Safety Injection (SI) HHSI to Cold Leg MOV 4

Both H

No Yes < or =

0.10 Yes Not Repaired MOV-4-843B Safety Injection (SI) HHSI to Cold Leg MOV 4

Both H

No Yes < or =

0.10 Yes Not Repaired Wednesday, February 21, 2018 Page 46 of 71

Owner/Operator PLANT Dkt #

MOV-4-860A Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No No No Not Repaired MOV-4-860B Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No Yes < or =

0.10 No Not Repaired MOV-4-861A Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No No No Not Repaired MOV-4-861B Residual Heat Removal (RHR)

Recirc Pump to RHR Pump Suction Motor Operated Valve 14 Open M

No No No Not Repaired MOV-4-862A Residual Heat Removal (RHR)

Motor Operated Stop Valve on RHR Pumps Suction Header 14 Close M

No Yes < or =

0.10 No Not Repaired MOV-4-862B Residual Heat Removal (RHR)

Motor Operated Stop Valve on RHR Pumps Suction Header 14 Close M

No Yes < or =

0.10 No Not Repaired MOV-4-864A Safety Injection (SI) RWST Motor Operated Isolation Valve to SI & RHR Pumps 16 Close M

No No No Not Repaired MOV-4-864B Safety Injection (SI) RWST Motor Operated Isolation Valve to SI & RHR Pumps 16 Close M

No No No Not Repaired MOV-4-865A Safety Injection (SI) SI Accumulator A Discharge Motor Operated Valve 10 None L

No No No Not Repaired MOV-4-865B Safety Injection (SI) SI Accumulator B Discharge Motor Operated Valve 10 None L

No Yes < or =

0.10 No Not Repaired MOV-4-865C Safety Injection (SI) SI Accumulator C Discharge Motor Operated Valve 10 None L

No Yes < or =

0.10 No Not Repaired MOV-4-869 Safety Injection (SI) SI to Loop A & B Hot Leg Motor Operated Isolation Valve 3

Both L

No Yes < or =

0.10 No Not Repaired MOV-4-880A Containment Spray Containment Spray Pump Discharge Isolation Valve 6

Open M

No Yes < or =

0.10 Yes Not Repaired MOV-4-880B Containment Spray Containment Spray Pump Discharge Isolation Valve 6

Open M

No No No Not Repaired Wednesday, February 21, 2018 Page 47 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 18 Total # of Valves Repaired 0

Total # of Valves Not Repaired 18 Total # High Risk Valves 2

Total # Med Risk Valves 10 Total # Low Risk Valves 6

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 9

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 78 Total # of Valves Repaired 0

Total # of Valves Not Repaired 78 Total # High Risk Valves 6

Total # Med Risk Valves 38 Total # Low Risk Valves 34 Total Thread Fric > 0.10 2

Total Thread Fric < or = 0.10 31 Total # Susceptible Valves 2

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Indiana/Michigan Power Co.

Cook 1 315 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments ICM-250 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "A" Outlet Containment Isolation Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-251 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "B" Outlet Containment Isolation Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-260 Emergency Core Cooling System (ECCS)

North Safety Injection Pump PP-26N Discharge Containment Isolation Valve 4

Close M

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-265 Emergency Core Cooling System (ECCS)

South Safety Injection Pump PP-265 Discharge Containment Isolation Valve 4

Close M

No No Yes < or

= 10 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-305 Emergency Core Cooling System (ECCS)

Recirculation Sump To East RHR/CTS Pumps Suction Containment Isolation Valve 18 Open H

No Yes < or =

0.10 No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-306 Emergency Core Cooling System (ECCS)

Recirculation Sump To West RHR/CTS Pumps Suction Containment Isolation Valve 18 Open H

No Yes < or =

0.10 Yes < or

= 5 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

Wednesday, February 21, 2018 Page 48 of 71

Owner/Operator PLANT Dkt #

IMO-255 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "A" Inlet Shutoff Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-256 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "B" Inlet Shutoff Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-310 Residual Heat Removal (RHR)

East RHR Pump PP-35E Suction Shutoff Valve 14 Close H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-314 Residual Heat Removal (RHR)

East RHR Heat Exchanger 1-HE-17E Discharge Crosstie Shutoff Valve 6

Close L

No No Yes < or

= 10 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-320 Residual Heat Removal (RHR)

West RHR Pump PP-35W Suction Shutoff Valve 14 Close H

No No Yes < or

= 5 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-324 Residual Heat Removal (RHR)

West RHR Heat Exchanger 1-HE-17W Discharge Crosstie Shutoff Valve 6

Close L

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-340 Residual Heat Removal (RHR)

East RHR Heat Exchanger to Charging Pumps Suction Shutoff Valve 8

Open H

No Yes < or =

0.10 No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-350 Residual Heat Removal (RHR)

West RHR Heat Exchanger Outlet to Safety Injection Pump Suction Shutoff Valve 8

Open H

No Yes < or =

0.10 Yes < or

= 5 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-390 Emergency Core Cooling System (ECCS)

Refueling Water Storage Tank TK-33 to Residual Heat Removal Pumps Suction Shutoff Valve 10 Close H

No No Yes < or

= 5 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

Total # of Valves 15 Total # of Valves Repaired 0

Total # of Valves Not Repaired 15 Total # High Risk Valves 11 Total # Med Risk Valves 2

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 0

Total # of Valves N/A 0

Cook 2 316 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 49 of 71

Owner/Operator PLANT Dkt #

ICM-250 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "A" Outlet Containment Isolation Valve 4

Open H

No No Yes < or

= 5 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-251 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "B" Outlet Containment Isolation Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-305 Emergency Core Cooling System (ECCS)

Recirculation Sump To East RHR/CTS Pumps Suction Containment Isolation Valve 18 Open H

No Yes < or =

0.10 No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

ICM-306 Emergency Core Cooling System (ECCS)

Recirculation Sump To West RHR/CTS Pumps Suction Containment Isolation Valve 18 Open H

No Yes < or =

0.10 No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-255 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "A" Inlet Shutoff Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-256 Emergency Core Cooling System (ECCS)

Boron Injection Tank Train "B" Inlet Shutoff Valve 4

Open H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-310 Residual Heat Removal (RHR)

East RHR Pump PP-35E Suction Shutoff Valve 14 Close H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-314 Residual Heat Removal (RHR)

East RHR Heat Exchanger 2-HE-17E Discharge Crosstie Shutoff Valve 6

Close L

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-320 Residual Heat Removal (RHR)

West RHR Pump PP-35W Suction Shutoff Valve 14 Close H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-324 Residual Heat Removal (RHR)

West RHR Heat Exchanger 2-HE-17W Discharge Crosstie Shutoff Valve 6

Close L

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-340 Residual Heat Removal (RHR)

East RHR Heat Exchanger to Charging Pumps Suction Shutoff Valve 8

Open H

No Yes < or =

0.10 No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

Wednesday, February 21, 2018 Page 50 of 71

Owner/Operator PLANT Dkt #

IMO-350 Residual Heat Removal (RHR)

West RHR Heat Exchanger Outlet to Safety Injection Pump Suction Shutoff Valve 8

Open H

No Yes < or =

0.10 Yes < or

= 10 deg.

Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

IMO-390 Emergency Core Cooling System (ECCS)

Refueling Water Storage Tank TK-33 to Residual Heat Removal Pumps Suction Shutoff Valve 10 Close H

No No No Not Repaired Since no valves were determined to be susceptible, no repair schedule has been provided. Applied wedge pin torque bounds anticipated design basis operating torque requirements and current maximum total torque.

Total # of Valves 13 Total # of Valves Repaired 0

Total # of Valves Not Repaired 13 Total # High Risk Valves 11 Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 4

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 28 Total # of Valves Repaired 0

Total # of Valves Not Repaired 28 Total # High Risk Valves 22 Total # Med Risk Valves 2

Total # Low Risk Valves 4

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 8

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Nebraska Public Power District Cooper 298 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments RR-MOV-MO53A Reactor Recirculation Reactor Recirc Pump A Discharge Isolation 28 Close L

Yes Yes > 0.10 Yes < or

= 20 deg.

Not Repaired RR-MOV-MO53B Reactor Recirculation Reactor Recirc Pump B Discharge Isolation 28 Close L

Yes Yes > 0.10 Yes < or

= 20 deg.

Not Repaired Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 2

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 51 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 2

Total # of Valves Repaired 0

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 2

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Pacific Gas & Electric Co.

Diablo Canyon 1 275 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments CS-1-9003A Containment Spray Residual Heat Removal Pump Discharge to Containment Spray Header 8

Both M

No Yes > 0.10 No Not Repaired CS-1-9003B Containment Spray Residual Heat Removal Pump Discharge to Containment Spray Header 8

Both M

No Yes > 0.10 No Not Repaired MS-1-FCV-95 Main Steam Main Steam Supply to Turbine Driven Auxiliary Feedwater Pump 4

Open H

No Yes > 0.10 No Repaired RHR-1-8700A Residual Heat Removal (RHR)

RHR Pump Suction Isolation 14 Both M

No Yes > 0.10 No Not Repaired RHR-1-8700B Residual Heat Removal (RHR)

RHR Pump Suction Isolation 14 Both M

No Yes > 0.10 No Not Repaired SI-1-8801A Safety Injection Charging Discharge Isolation Valve 4

Open H

No Yes > 0.10 No Not Repaired SI-1-8801B Safety Injection Charging Discharge Isolation Valve 4

Open H

No Yes > 0.10 No Not Repaired SI-1-8802A Safety Injection Safety Injection to Hot Leg Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired SI-1-8802B Safety Injection Safety Injection to Hot Leg Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired SI-1-8803A Safety Injection Charging Discharge Isolation Valve 4

Open H

No Yes > 0.10 No Not Repaired Wednesday, February 21, 2018 Page 52 of 71

Owner/Operator PLANT Dkt #

SI-1-8803B Safety Injection Charging Discharge Isolation Valve 4

Open H

No Yes > 0.10 No Not Repaired SI-1-8804A Safety Injection Residual Heat Removal Pump Discharge to Charging Pump Suction 8

Both M

No Yes > 0.10 No Repaired SI-1-8804B Safety Injection Residual Heat Removal Pump Discharge to Charging Pump Suction 8

Both M

No Yes > 0.10 No Not Repaired SI-1-8835 Safety Injection Safety Injection Pump Discharge to Cold Legs Isolation Valve 4

Open L

No Yes > 0.10 No Not Repaired SI-1-8982A Safety Injection Containment Recirculation Sump to RHR Pump Suction 14 Both H

No Yes > 0.10 No Not Repaired SI-1-8982B Safety Injection Containment Recirculation Sump to RHR Pump Suction 14 Both H

No Yes > 0.10 No Repaired Total # of Valves 16 Total # of Valves Repaired 3

Total # of Valves Not Repaired 13 Total # High Risk Valves 7

Total # Med Risk Valves 6

Total # Low Risk Valves 3

Total Thread Fric > 0.10 16 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Diablo Canyon 2 323 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments CS-2-9003A Containment Spray Residual Heat Removal Pump Discharge to Containment Spray Header 8

Both M

No Yes > 0.10 No Not Repaired CS-2-9003B Containment Spray Residual Heat Removal Pump Discharge to Containment Spray Header 8

Both M

No Yes > 0.10 No Not Repaired RHR-2-8700A Residual Heat Removal (RHR)

RHR Pump Suction Isolation 14 Both M

No Yes > 0.10 No Not Repaired RHR-2-8700B Residual Heat Removal (RHR)

RHR Pump Suction Isolation 14 Both M

No Yes > 0.10 No Not Repaired SI-2-8802A Safety Injection Safety Injection to Hot Leg Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired SI-2-8802B Safety Injection Safety Injection to Hot Leg Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired Wednesday, February 21, 2018 Page 53 of 71

Owner/Operator PLANT Dkt #

SI-2-8804A Safety Injection Residual Heat Removal Pump Discharge to Charging Pump Suction 8

Both M

No Yes > 0.10 No Not Repaired SI-2-8804B Safety Injection Residual Heat Removal Pump Discharge to Charging Pump Suction 8

Both M

No Yes > 0.10 No Not Repaired SI-2-8835 Safety Injection Safety Injection Pump Discharge to Cold Legs Isolation Valve 4

Open L

No Yes > 0.10 No Not Repaired SI-2-8982A Safety Injection Containment Recirculation Sump to RHR Pump Suction 14 Both H

No Yes > 0.10 No Not Repaired SI-2-8982B Safety Injection Containment Recirculation Sump to RHR Pump Suction 14 Both H

No Yes > 0.10 No Not Repaired VAC-2-FCV-658 Containment Ventilation Hydrogen Purge / Recombiner Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired VAC-2-FCV-659 Containment Ventilation Hydrogen Purge / Recombiner Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired VAC-2-FCV-668 Containment Ventilation Hydrogen Purge / Recombiner Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired VAC-2-FCV-669 Containment Ventilation Hydrogen Purge / Recombiner Isolation Valve 4

Both L

No Yes > 0.10 No Not Repaired Total # of Valves 15 Total # of Valves Repaired 0

Total # of Valves Not Repaired 15 Total # High Risk Valves 2

Total # Med Risk Valves 6

Total # Low Risk Valves 7

Total Thread Fric > 0.10 15 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 31 Total # of Valves Repaired 3

Total # of Valves Not Repaired 28 Total # High Risk Valves 9

Total # Med Risk Valves 12 Total # Low Risk Valves 10 Total Thread Fric > 0.10 31 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

PSE&G Nuclear Wednesday, February 21, 2018 Page 54 of 71

Owner/Operator PLANT Dkt #

Hope Creek 354 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Salem 1 272 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments S1CC-1CC117-MTRY Component Cooling (CC)

RCP CC Inlet MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1CC-1CC118-MTRY Component Cooling (CC)

RCP CC Inlet MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1CC-1CC136-MTRY Component Cooling (CC)

RCP BRG MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1CC-1CC187-MTRY Component Cooling (CC)

RCP MOT BRG CC MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1CS-11CS36-MTRY Containment Spray RHR CS Stop Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1CS-12CS36-MTRY Containment Spray RHR CS Stop Valve 8

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1RHR-11RH19-MT RY Residual Heat Removal (RHR)

HRH Heat Exchanger Discharge Cross Connect MOV 8

Close L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1RHR-11RH4-MTR Y

Residual Heat Removal (RHR)

RHR Pump Suction MOV 14 Close M

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1RHR-12RH19-MT RY Residual Heat Removal (RHR)

HRH Heat Exchanger Discharge Cross Connect MOV 8

Close L

No Yes > 0.10 Yes < or

= 5 deg.

Repaired Wednesday, February 21, 2018 Page 55 of 71

Owner/Operator PLANT Dkt #

S1RHR-12RH4-MTR Y

Residual Heat Removal (RHR)

RHR Pump Suction MOV 14 Close M

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1SJ-11SJ40-MTRY Safety Injection SI Header Stop Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Due for diagnostic testing in 1R26 S1SJ-11SJ44-MTRY Safety Injection Containment Sump Suction Valve 14 Both M

No Yes > 0.10 Yes < or

= 5 deg.

Repaired S1SJ-11SJ45-MTRY Safety Injection RHR to SI Pumps Stop MOV 8

Open M

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Medium risk must be repaired in 1R26 S1SJ-12SJ40-MTRY Safety Injection SI Header Stop Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Repaired S1SJ-12SJ44-MTRY Safety Injection Containment Sump Suction Valve 14 Both M

No Yes > 0.10 Yes < or

= 5 deg.

Repaired S1SJ-12SJ45-MTRY Safety Injection RHR to Charging SI Pumps Stop MOV 8

Open M

No Yes > 0.10 Yes < or

= 5 deg.

Repaired S1SJ-1SJ12-MTRY Safety Injection BIT Outlet Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1SJ-1SJ135-MTRY Safety Injection SJ Discharge to Cold Legs Valve 4

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S1SJ-1SJ13-MTRY Safety Injection BIT Outlet Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1SJ-1SJ14-MTRY Safety Injection BIT Inlet Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 S1SJ-1SJ15-MTRY Safety Injection BIT Inlet Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired 1R26 or 1R27 Total # of Valves 21 Total # of Valves Repaired 5

Total # of Valves Not Repaired 16 Total # High Risk Valves 0

Total # Med Risk Valves 6

Total # Low Risk Valves 15 Total Thread Fric > 0.10 14 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Salem 2 311 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 56 of 71

Owner/Operator PLANT Dkt #

S2CC-2CC117-MTRY Component Cooling (CC)

RCP CC Inlet MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S2CC-2CC118-MTRY Component Cooling (CC)

RCP CC Inlet MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S2CC-2CC136-MTRY Component Cooling (CC)

RCP BRG MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S2CC-2CC187-MTRY Component Cooling (CC)

RCP MOT BRG CC MOV 6

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S2RHR-21RH4-MTR Y

Residual Heat Removal (RHR)

RHR Pump Suction MOV 14 Close M

No No Yes < or

= 5 deg.

Not Repaired Pin shear only. Internal inspection performed April, 2017. No issue identified during internal inspection.

S2RHR-22RH4-MTR Y

Residual Heat Removal (RHR)

RHR Pump Suction MOV 14 Close M

No No Yes < or

= 5 deg.

Not Repaired Pin shear only S2SJ-21SJ40-MTRY Safety Injection SI Header Stop Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair scoped into 2R23 S2SJ-21SJ44-MTRY Safety Injection Containment Sump Suction Valve 14 Both M

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair scoped into 2R23 S2SJ-22SJ40-MTRY Safety Injection SI Header Stop Valve 4

Both L

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair scoped into 2R23 S2SJ-22SJ44-MTRY Safety Injection Containment Sump Suction Valve 14 Both M

No Yes > 0.10 Yes < or

= 5 deg.

Not Repaired Repair scoped into 2R23 S2SJ-2SJ135-MTRY Safety Injection SJ Discharge to Cold Legs Valve 4

Close L

No No Yes < or

= 5 deg.

Not Repaired Pin shear only Total # of Valves 11 Total # of Valves Repaired 0

Total # of Valves Not Repaired 11 Total # High Risk Valves 0

Total # Med Risk Valves 4

Total # Low Risk Valves 7

Total Thread Fric > 0.10 4

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 32 Total # of Valves Repaired 5

Total # of Valves Not Repaired 27 Total # High Risk Valves 0

Total # Med Risk Valves 10 Total # Low Risk Valves 22 Total Thread Fric > 0.10 18 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 57 of 71

Owner/Operator PLANT Dkt #

South Carolina Electric & Gas Co.

V.C. Summer 395 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments XVG03004A-SP Reactor Building Spray RB Spray Sump Isolation Valve A (IRC) 12 Both L

Yes No Yes any moveme nt Repaired Repaired 2014 WO 1308677 XVG03004B-SP Reactor Building Spray RB Spray Sump Isolation Valve B (IRC) 12 Both L

Yes No Yes any moveme nt Repaired Repaired 2014 WO 1308682 Total # of Valves 2

Total # of Valves Repaired 2

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Total # of Valves N/A 0

Total # of Valves 2

Total # of Valves Repaired 2

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 2

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 2

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Southern Nuclear Operating Co.

Farley 1 348 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Farley 2 364 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 58 of 71

Owner/Operator PLANT Dkt #

Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Hatch 1 321 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Hatch 2 366 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Vogtle 1 424 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Wednesday, February 21, 2018 Page 59 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Vogtle 2 425 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

STP Nuclear Operating Co.

South Texas 1 498 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

South Texas 2 499 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Wednesday, February 21, 2018 Page 60 of 71

Owner/Operator PLANT Dkt #

Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Talen Energy Susquehanna 1 387 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Susquehanna 2 388 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 61 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Tennessee Valley Authority Browns Ferry 1 259 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1-FCV-001-0055 Main Steam Main Steam Drain Inboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

1-FCV-001-0056 Main Steam Main Steam Drain Outboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

1-FCV-068-0003 Reactor Recirculation Reactor Recirc Pump A Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Fall 2022 refueling outage. ADAMS ML18016A032 1-FCV-068-0079 Reactor Recirculation Reactor Recirc Pump B Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Fall 2022 refueling outage. ADAMS ML18016A032 1-FCV-069-0001 Reactor Water Cleanup (RWCU)

RWCU Inboard Containment Isolation Valve 6

Close M

Yes No No Repaired 1-FCV-069-0002 Reactor Water Cleanup (RWCU)

RWCU Outboard Containment Isolation Valve 6

Close M

Yes Yes > 0.10 No Repaired 1-FCV-071-0002 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Inboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

1-FCV-071-0003 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Outboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

1-FCV-073-0002 High Pressure Coolant Injection (HPCI)

HPCI Inboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired Wednesday, February 21, 2018 Page 62 of 71

Owner/Operator PLANT Dkt #

1-FCV-073-0003 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired 1-FCV-073-0081 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Bypass Valve 1

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

1-FCV-075-0009 Core Spray Caore Spray System I Minimum Flow Valve 3

Both L

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Fall 2022 refueling outage. ADAMS ML18016A032 1-FCV-075-0037 Core Spray Caore Spray System II Minimum Flow Valve 3

Both L

Yes Yes > 0.10 Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Fall 2022 refueling outage. ADAMS ML18016A032 Total # of Valves 13 Total # of Valves Repaired 4

Total # of Valves Not Repaired 4

Total # High Risk Valves 0

Total # Med Risk Valves 6

Total # Low Risk Valves 7

Total Thread Fric > 0.10 5

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 8

Total # of Valves N/A 5

Browns Ferry 2 260 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-FCV-001-0055 Main Steam Main Steam Drain Inboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

2-FCV-001-0056 Main Steam Main Steam Drain Outboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

2-FCV-068-0003 Reactor Recirculation Reactor Recirc Pump A Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Spring 2021 refueling outage. ADAMS ML18016A032 2-FCV-068-0079 Reactor Recirculation Reactor Recirc Pump B Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Spring 2021 refueling outage. ADAMS ML18016A032 2-FCV-069-0001 Reactor Water Cleanup (RWCU)

RWCU Inboard Containment Isolation Valve 6

Close M

Yes No No Repaired Wednesday, February 21, 2018 Page 63 of 71

Owner/Operator PLANT Dkt #

2-FCV-069-0002 Reactor Water Cleanup (RWCU)

RWCU Outboard Containment Isolation Valve 6

Close M

Yes Yes > 0.10 No Repaired 2-FCV-071-0002 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Inboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

2-FCV-071-0003 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Outboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

2-FCV-073-0002 High Pressure Coolant Injection (HPCI)

HPCI Inboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired 2-FCV-073-0003 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired 2-FCV-073-0081 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Bypass Valve 1

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

Total # of Valves 11 Total # of Valves Repaired 4

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 6

Total # Low Risk Valves 5

Total Thread Fric > 0.10 3

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Total # of Valves N/A 5

Browns Ferry 3 296 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 3-FCV-001-0055 Main Steam Main Steam Drain Inboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

3-FCV-001-0056 Main Steam Main Steam Drain Outboard Isolation Valve 3

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

3-FCV-068-0003 Reactor Recirculation Reactor Recirc Pump A Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Spring 2022 refueling outage. ADAMS ML18016A032 3-FCV-068-0079 Reactor Recirculation Reactor Recirc Pump B Discharge Valve 24 Close L

Yes No Yes < or

= 5 deg.

Not Repaired By April 30, 2018 TVA will complete its review based on TP16 112r4 of BFN Anchor Darling Double Disc Gate Valves with active safety functions to determine which valves require repair.

Update 1/11/2018 - Valve will be repaired no later than the Spring 2022 refueling outage. ADAMS ML18016A032 Wednesday, February 21, 2018 Page 64 of 71

Owner/Operator PLANT Dkt #

3-FCV-069-0001 Reactor Water Cleanup (RWCU)

RWCU Inboard Containment Isolation Valve 6

Close M

Yes Yes > 0.10 No Repaired 3-FCV-069-0002 Reactor Water Cleanup (RWCU)

RWCU Outboard Containment Isolation Valve 6

Close M

Yes Yes > 0.10 No Repaired 3-FCV-071-0002 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Inboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

3-FCV-071-0003 Reactor Core Isolation Coolant (RCIC)

RCIC Steam Supply Outboard Containment Isolation Valve 3

Close M

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

3-FCV-073-0002 High Pressure Coolant Injection (HPCI)

HPCI Inboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired 3-FCV-073-0003 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Valve 10 Close M

Yes Yes > 0.10 No Repaired 3-FCV-073-0081 High Pressure Coolant Injection (HPCI)

HPCI Outboard Containment Isolation Bypass Valve 1

Close L

No No No N/A Valve is not applicable to Part 21 due to T-Head Design.

Total # of Valves 11 Total # of Valves Repaired 4

Total # of Valves Not Repaired 2

Total # High Risk Valves 0

Total # Med Risk Valves 6

Total # Low Risk Valves 5

Total Thread Fric > 0.10 4

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Total # of Valves N/A 5

Sequoyah 1 327 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 1-FCV-063-0008-A Safety Injection RHR Heat Exchanger A to CVCS Charging Pumps 8

Both H

No No No Repaired 1-FCV-063-0011-B Safety Injection RHR Heat Exchanger B to SIS Pumps 8

Both H

No No No Repaired 1-FCV-063-0022-B Safety Injection SIS Pumps Cold Leg Injection 4

Both L

Yes No No Not Repaired Valve is scheduled to be repaired during the Spring 2018 refueling outage.

1-FCV-063-0025-B Safety Injection SIS CCP Injection Tank Shutoff Valve 4

Both L

No No No Repaired 1-FCV-063-0026-A Safety Injection SIS CCP Injection Tank Shutoff Valve 4

Both L

No No No Repaired Wednesday, February 21, 2018 Page 65 of 71

Owner/Operator PLANT Dkt #

1-FCV-063-0039-A Safety Injection SIS CCP Injection Tank Inlet Shutoff Valve 4

Both L

No No No Repaired 1-FCV-063-0040-B Safety Injection SIS CCP Injection Tank Inlet Shutoff Valve 4

Both L

No No No Repaired 1-FCV-063-0072-A Safety Injection Containment Sump Flow Isolation Valve 18 Both H

No No No Repaired 1-FCV-063-0073-B Safety Injection Containment Sump Flow Isolation Valve 18 Both H

No No No Repaired 1-FCV-074-0003-A Residual Heat Removal (RHR)

RHR Pump A-A Inlet Flow Control Valve 14 Both H

No No No Repaired 1-FCV-074-0021-B Residual Heat Removal (RHR)

RHR Pump B-B Inlet Flow Control Valve 14 Both H

No No No Repaired 1-FCV-074-0033-A Residual Heat Removal (RHR)

RHR Heat Exchanger A Bypass 8

Both M

Yes No No Not Repaired Valve is scheduled to be repaired during the Spring 2018 refueling outage.

1-FCV-074-0035-B Residual Heat Removal (RHR)

RHR Heat Exchanger B Bypass 8

Both M

Yes No No Not Repaired Valve is scheduled to be repaired during the Spring 2018 refueling outage.

Total # of Valves 13 Total # of Valves Repaired 10 Total # of Valves Not Repaired 3

Total # High Risk Valves 6

Total # Med Risk Valves 2

Total # Low Risk Valves 5

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 3

Total # of Valves N/A 0

Sequoyah 2 328 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments 2-FCV-063-0008-A Safety Injection RHR Heat Exchanger A to CVCS Charging Pumps 8

Both H

No No No Repaired 2-FCV-063-0011-B Safety Injection RHR Heat Exchanger B to SIS Pumps 8

Both H

No No No Repaired 2-FCV-063-0022-B Safety Injection SIS Pumps Cold Leg Injection 4

Both L

Yes No No Not Repaired Valve is scheduled to be repaired during the Fall 2018 refueling outage.

2-FCV-063-0025-B Safety Injection SIS CCP Injection Tank Shutoff Valve 4

Both L

No No No Repaired Wednesday, February 21, 2018 Page 66 of 71

Owner/Operator PLANT Dkt #

2-FCV-063-0026-A Safety Injection SIS CCP Injection Tank Shutoff Valve 4

Both L

No No No Repaired 2-FCV-063-0039-A Safety Injection SIS CCP Injection Tank Inlet Shutoff Valve 4

Both L

No No No Repaired 2-FCV-063-0040-B Safety Injection SIS CCP Injection Tank Inlet Shutoff Valve 4

Both L

No No No Repaired 2-FCV-063-0072-A Safety Injection Containment Sump Flow Isolation Valve 18 Both H

No No No Repaired 2-FCV-063-0073-B Safety Injection Containment Sump Flow Isolation Valve 18 Both H

No No No Repaired 2-FCV-074-0003-A Residual Heat Removal (RHR)

RHR Pump A-A Inlet Flow Control Valve 14 Both H

Yes No No Not Repaired Valve is scheduled to be repaired during the Fall 2018 refueling outage.

2-FCV-074-0021-B Residual Heat Removal (RHR)

RHR Pump B-B Inlet Flow Control Valve 14 Both H

Yes No No Not Repaired Valve is scheduled to be repaired during the Fall 2018 refueling outage.

2-FCV-074-0033-A Residual Heat Removal (RHR)

RHR Heat Exchanger A Bypass 8

Both M

No No No Repaired 2-FCV-074-0035-B Residual Heat Removal (RHR)

RHR Heat Exchanger B Bypass 8

Both M

Yes No No Not Repaired Valve is scheduled to be repaired during the Fall 2018 refueling outage.

Total # of Valves 13 Total # of Valves Repaired 9

Total # of Valves Not Repaired 4

Total # High Risk Valves 6

Total # Med Risk Valves 2

Total # Low Risk Valves 5

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 4

Total # of Valves N/A 0

Watts Bar 1 390 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 67 of 71

Owner/Operator PLANT Dkt #

Watts Bar 2 391 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 61 Total # of Valves Repaired 31 Total # of Valves Not Repaired 15 Total # High Risk Valves 12 Total # Med Risk Valves 22 Total # Low Risk Valves 27 Total Thread Fric > 0.10 12 Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 27 Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 15 Vistra Energy Corp Comanche Peak 1 445 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Comanche Peak 2 446 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments Licensee does not use Anchor/Darling Double Disc Gate Valves Wednesday, February 21, 2018 Page 68 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 0

Total # of Valves Repaired 0

Total # of Valves Not Repaired 0

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Wolf Creek Nuclear Operating Corp.

Wolf Creek 1 482 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments EGHV0058 Component Cooling Water (CCW)

CCW to RCS Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired EGHV0059 Component Cooling Water (CCW)

CCW Return From RCS Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired EGHV0060 Component Cooling Water (CCW)

CCW Return From RCS Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired EGHV0127 Component Cooling Water (CCW)

CCW to RCS HV-58 & HV-71 Bypass Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired Passive valve EGHV0130 Component Cooling Water (CCW)

RCS CCW Return HV-60 Bypass Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired Passive valve EGHV0131 Component Cooling Water (CCW)

RCS CCW Return HV-59 Bypass Isolation Valve (CTMT ISO) 2 Close H

Yes No No Repaired Passive valve Total # of Valves 6

Total # of Valves Repaired 6

Total # of Valves Not Repaired 0

Total # High Risk Valves 6

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Total # of Valves N/A 0

Wednesday, February 21, 2018 Page 69 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 6

Total # of Valves Repaired 6

Total # of Valves Not Repaired 0

Total # High Risk Valves 6

Total # Med Risk Valves 0

Total # Low Risk Valves 0

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 6

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Xcel Energy Monticello 263 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MO-2030 Residual Heat Removal (RHR)

RHR Shutdown Cooling Outbaird Isolation Valve 18 Close L

No Yes < or =

0.10 Yes < or

= 5 deg.

Not Repaired MO-2035 High Pressure Coolant Injection (HPCI)

HPCI Steam Line Outboard Isolation Valve 8

Close L

No No No Repaired MO-2071 High Pressure Coolant Injection (HPCI)

HPCI Test Return Isolation Valve 8

Close L

No No No Repaired MO-2397 Reator Water Cleanup (RWCU)

RWCU Inlet Inboard Isolation Valve 4

Close L

No No No Repaired MO-2398 Reator Water Cleanup (RWCU)

RWCU Inlet Outboard Isolation Valve 4

Close L

No No Yes < or

= 5 deg.

Repaired Total # of Valves 5

Total # of Valves Repaired 4

Total # of Valves Not Repaired 1

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 5

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 0

Total # of Valves N/A 0

Prairie Island 1 282 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MV-32115 Component Cooling Water (CCW) 122 Spent Fuel Pol Heat Exchanger Inlet Header Motor Valve 8

Close L

No No No Not Repaired Wednesday, February 21, 2018 Page 70 of 71

Owner/Operator PLANT Dkt #

Total # of Valves 1

Total # of Valves Repaired 0

Total # of Valves Not Repaired 1

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Prairie Island 2 306 Valve ID System Func Description Size Func Risk Susc Thread Fric Rot Check Repair Status Industry Comments MV-32117 Component Cooling Water (CCW) 121 Spent Fuel Pol Heat Exchanger Inlet Header Motor Valve 8

Close L

No No No Not Repaired Total # of Valves 1

Total # of Valves Repaired 0

Total # of Valves Not Repaired 1

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 1

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 0

Total # Susceptible Valves 0

Total # of Valves N/A 0

Total # of Valves 7

Total # of Valves Repaired 4

Total # of Valves Not Repaired 3

Total # High Risk Valves 0

Total # Med Risk Valves 0

Total # Low Risk Valves 7

Total Thread Fric > 0.10 0

Total Thread Fric < or = 0.10 1

Total # Susceptible Valves 0

Owner/Operator Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 0

Total # of Valves 584 Total # of Valves Repaired 119 Total # of Valves Not Repaired 425 Total # High Risk Valves 106 Total # Med Risk Valves 163 Total # Low Risk Valves 305 Total Thread Fric > 0.10 182 Total Thread Fric < or = 0.10 59 Total # Susceptible Valves 157 Anchor Darling Double Disc Gate Valve Population Totals Total # of Valves N/A 40 Wednesday, February 21, 2018 Page 71 of 71