ML12165A126
| ML12165A126 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island (DPR-042, DPR-060) |
| Issue date: | 05/22/2012 |
| From: | Mcneil D Operations Branch III |
| To: | Northern States Power Co, Xcel Energy |
| References | |
| Download: ML12165A126 (107) | |
Text
U.S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Name:
Date: May 22, 2012 Facility/Unit: Prairie Island NGP U1/U2 Region:
I II III IV Reactor Type:W CE BW GE Start Time:
Finish Time:
Instructions Use the answer sheets provided to document your answers. Present this cover sheet on top of the answer sheets. To pass the examination, you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the examination begins.
Applicant Certification All work done on this examination is my own. I have neither given nor received aid.
Applicants Signature Results Examination Value 75 Points Applicants Score Points Applicants Grade Percent
U.S. Nuclear Regulatory Commission Site-Specific SRO Written Examination Applicant Information Name:
Date: May 22, 2012 Facility/Unit: Prairie Island NGP U1/U2 Region:
I II III IV Reactor Type:W CE BW GE Start Time:
Finish Time:
Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination you must achieve a final grade of at least 80.00 percent overall, with 70.00 percent or better on the SRO-only items if given in conjunction with the RO exam; SRO-only exams given alone require a final grade of 80.00 percent to pass. You have 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to complete the combined examination, and 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> if you are only taking the SRO portion.
Applicant Certification All work done on this examination is my own. I have neither given nor received aid.
Applicants Signature Results RO/SRO-Only/Total Examination Values 75 / 25 / 100 Points Applicants Scores
/ / Points Applicants Grade
/ / Percent
POLICIES AND GUIDELINES FOR TAKING NRC WRITTEN EXAMINATIONS Page 1 of 2 Each examinee shall be briefed on the policies and guidelines applicable to the examination category (written, operating, walk-through, and/or simulator test) being administered. The examinees may be briefed individually or as a group. Facility licensees are encouraged to distribute a copy of this appendix to every examinee before the examination begins. All items apply to both initial and requalification examinations, except as noted.
Part A: General Guidelines
- 1.
[Read Verbatim] Cheating on any part of the examination will result in a denial of your application and/or action against your license.
- 2.
If you have any questions concerning the administration of any part of the examination, do not hesitate to ask them before starting that part of the test.
- 3.
SRO applicants will be tested at the level of responsibility of the senior licensed shift position (i.e., shift supervisor, senior shift supervisor, or whatever the title of the position may be).
- 4.
You must pass every part of the examination to receive a license or to continue performing license duties. Applicants for an SRO-upgrade license may require remedial training in order to continue their RO duties if the examination reveals deficiencies in the required knowledge and abilities.
- 5.
The NRC examiner is not allowed to reveal the results of any part of the examination until they have been reviewed and approved by NRC management. Grades provided by the facility licensee are preliminary until approved by the NRC. You will be informed of the official examination results about 30 days after all the examinations are complete.
Part B: Written Examination Guidelines
- 1. [Read Verbatim] After you complete the examination, sign the statement on the cover sheet indicating that the work is your own and you have not received or given assistance in completing the examination.
- 2. To pass the examination, you must achieve an overall grade of 80.00 percent or greater, with 70.00 percent or greater on the SRO-only items, if applicable. If you take only the SRO portion of the exam (as a retake or with an upgrade waiver of the RO exam), you must achieve an overall grade of 80.00 percent or better to pass. SRO-upgrade applicants who do take the RO portion of the exam an score below 80.00 percent on that part of the exam can still pass overall, but may require remediation. Grades will not be rounded up to achieve a passing score. Every question is worth one point.
- 3. For an initial examination, the nominal time limit for completing the examination is 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for the RO exam; 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> for the 25-question SRO-only exam; 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for the combined RO/SRO exam. Notify the proctor if you need more time.
- 4. You may bring pens, pencils, and calculators into the examination room; however, programmable memories must be erased. Use dark pencil to facilitate machine grading.
POLICIES AND GUIDELINES FOR TAKING NRC WRITTEN EXAMINATIONS Page 2 of 2
- 5. Print your name in the blank provided on the examination cover sheet and the answer sheet. Print your name on the first page of the examination, the facility will retain the examinations and you will want to see your own examination during the exam review.
- 6. Mark your answers on the answer sheet provided. Use the paper provided, and write on the back side of the pages to document your thought process. If you have recorded an incorrect answer on your answer sheet, carefully erase and mark the correct answer. If the scan-tron and chief examiner cannot determine which answer you intended, the answer will be marked as incorrect. If you have an e column do not mark any answer in that column. It will not be considered as a d answer, it will be marked as incorrect. If you mark answer d. on your examination and c. on the answer sheet, your official answer is c. even if d. is the correct answer.
- 7. If you have any questions concerning the intent or the initial conditions of a question, do not hesitate to ask them before answering the question. Note that questions asked during the examination are taken into consideration during the grading process and when reviewing applicant appeals. Ask questions of the NRC examiner or the designated facility instructor only. A dictionary is available if you need it.
When answering a question, do not make assumptions regarding conditions that are not specified in the question unless they occur as a consequence of other conditions that are stated in the question. For example, you should not assume that any alarm has activated unless the question so states or the alarm is expected to activate as a result of the conditions that are stated in the question. Similarly, you should assume that no operator actions have been taken, unless the stem of the question or the answer choices specifically state otherwise. Finally, answer all questions based on actual plant operation, procedures, and references. If you believe that the answer would be different based on simulator operation or training references, you should answer the question based on the actual plant.
- 8. Restroom trips are permitted, but only one applicant at a time will be allowed to leave.
Avoid all contact with anyone outside the examination room to eliminate even the appearance or possibility of cheating.
- 9. When you complete the examination, assemble a package that includes the examination answer sheets and cover sheet and give it to the NRC examiner or proctor. Leave the remaining materials at your workstation, face-down. Remember to sign the statement on the examination cover sheet indicating that the work is your own and that you have neither given nor received assistance in completing the examination. The scrap paper will be disposed of immediately after the examination.
- 10.
After turning in your examination, leave the examination area as defined by the proctor or NRC examiner. If you are found in this area while the examination is still in progress, your license may be denied or revoked.
- 11.
Do you have any questions?
REACTOR OPERATOR Page 1 of 102 Question #
001 Given the following conditions:
Unit 1 was at 100% power.
A Reactor Trip occurred.
1ES-0.1, Reactor Trip Recovery, is in progress.
RCS Tave is 550°F and lowering.
Both RCPs are running.
11 SG NR level is 42% and rising.
12 SG NR level is 46% and rising.
Auxiliary feedwater (AFW) flow is approximately 500 GPM.
What is/are the required action(s) concerning the main and auxiliary feedwater systems?
- a. Stop dumping steam AND reduce total feed flow until both SG NR levels are less than 5%.
- b. Immediately reduce AFW flow AND maintain narrow range level between 5% and 36%.
- c. Manually close feedwater containment isolation valves (MV-32023 and MV-32024).
- d. Maintain total feed flow greater than 200 GPM using the Main FW bypass Valves.
REACTOR OPERATOR Page 2 of 102 Question #
002 Given the following conditions:
Unit 1 is at 100% power.
All tailpipe temperatures are 86°F and stable.
47012-0109, PRZR SAFETY/RELIEF VALVE FLOW, is LIT.
No operator action has been taken.
ERCS indications are as follows:
Indication upon alarm 10 Minutes after alarm Based on the above conditions, a Pressurizer __________________________.
- a. PORV is CLOSED and LEAKING by
- b. PORV is FULL open
- c. Safety is CLOSED and LEAKING by
- d. Safety is FULL open
REACTOR OPERATOR Page 3 of 102 Question #
003 Given the following conditions:
Unit 1 experienced a LOCA 30 minutes ago.
1E-1, Loss of Reactor or Secondary Coolant, is in-progress.
All ECCS Pumps are running.
RCS Pressure is 1400 psig and stable.
Which of the following alarms is lit in the Control Room?
- a. 47016-0104, 11 RWST LO-LO LVL
- c. 47016-0604, RESIDUAL HEAT REMOVAL SYSTEM TROUBLE
- d. 47018-0201, 11 SI PUMP OVERLOAD
REACTOR OPERATOR Page 4 of 102 Question #
004 Given the following conditions:
A LOCA occurred on Unit 1.
Core Exit Thermocouples are 300°F and slowly lowering.
RCS pressure is slightly higher than containment pressure.
SG pressures are 675 psig and slowly lowering.
Heat removal is occurring by ___________________.
Heat removal will be continued by maintaining _________________________________.
- a. break flow ONLY at least the minimum necessary ECCS injection flow
- b. break flow ONLY SG NR level using aux feed, and reducing steam pressure using SG PORVs or Steam Dumps to the condenser if available
- c. reflux cooling ONLY SG NR level using aux feed, and reducing steam pressure using SG PORVs or Steam Dumps to the condenser if available
- d. reflux cooling ONLY at least the minimum necessary ECCS injection flow
REACTOR OPERATOR Page 5 of 102 Question #
005 Given the following conditions:
Unit 1 was operating at 100%.
47012-0102, 12 RCP LOCKED OUT is NOT lit.
47012-0202, 12 RCP OVERLOAD is NOT lit.
12 RCP current is 100 amps.
ALL 3 Loop B RC flow meters read 20%.
The 12 RCP
- a. impeller has seized within the pump casing.
- b. flywheel has separated from the motor shaft.
- c. shaft has sheared at the motor to pump coupling.
- d. has an electrical fault in the stator windings with no breaker trip.
REACTOR OPERATOR Page 6 of 102 Question #
006 Given the following conditions:
Unit 1 experienced a Large Break LOCA.
RHR is operating in recirculation mode.
47019-0501, 11 ANNULUS SUMP HI LVL, alarms.
Containment level is 4.5 feet and lowering rapidly.
Sump B will ___________ and RHR recirculation will ______________.
- a. empty out into the annulus be lost
- b. maintain level once Annulus Sump Pumps start to transfer the water back into sump B not be interrupted
- d. maintain level once Annulus Sump Pumps overfill sump A and it overflows into Sump B not be interrupted
REACTOR OPERATOR Page 7 of 102 Question #
007 Given the following conditions:
Unit 2 is at 100% power.
Steam Generator Blowdown (SGB) is aligned to the discharge canal.
2R-19, Steam Generator Blowdown Radiation Monitor, HIGH alarm actuates.
Which of the following automatic actions occurred, and why are the automatic actions required?
Actions Reason
- a. 21 and 22 SGB motor operated Minimize the effects of inadvertent release containment isolation valves go CLOSE.
of radioactivity to the environment.
- b. 21 and 22 SGB flow control valves Minimize exhaustion of the cation/anion to the 21 SGB flash tank go CLOSE.
resin beds in the SGB ion exchangers.
- c. 21 and 22 SGB flow control valves Minimize the effects of inadvertent release to the 21 SGB flash tank go CLOSE.
of radioactivity to the environment.
- d. 21 and 22 SGB motor operated Minimize exhaustion of the cation/anion containment isolation valves go CLOSE.
resin beds in the SGB ion exchangers
REACTOR OPERATOR Page 8 of 102 Question #
008 Given the following conditions:
Unit 1 was at 50% power and at End Of Cycle (EOC).
Rod Control was in manual.
12 SG experienced a Main Steam Line Break UPSTREAM of the MSIV.
No operator actions have occurred.
How will reactor power respond during the initial phase of the MSLB?
- b. Reactor power will initially rise and then return to the original value of 50% rated power when the 12 SG is dry.
- c. Reactor power will initially rise and then lower and stabilize at approximately 25% rated power.
- d. Reactor power will rise rapidly until terminated by a reactor trip generated by the SI initiation signal.
REACTOR OPERATOR Page 9 of 102 Question #
009 Given the following conditions:
Unit 2 was at 6% power.
22 Condensate Pump was running.
21 Main Feed Pump was running.
The 22 Condensate Pump locks out.
Assume no operator action.
What will the final configuration of the following components be?
21 MD AFWP ______.
22 TD AFWP ______.
21 MD AFWP discharge valves ______.
22 TD AFWP discharge valves ______.
- a.
starts starts remain open remain open
- b.
remains in standby starts shut remain open
- c.
starts remains in standby remain open shut
- d.
remains in standby remains in standby remain open remain open
REACTOR OPERATOR Page 10 of 102 Question #
010 Given the following conditions:
Unit 1 is shutdown in Mode 4.
D1 is out of service for maintenance.
Unit 2 is at 100% power.
A LOOP occurs to both units.
D2 does NOT start.
Which EOP entry conditions, for both Units, were met?
Unit 1 Unit 2
- a.
- b.
- c.
- d.
REACTOR OPERATOR Page 11 of 102 Question #
011 Given the following conditions:
One hour ago Unit 1 tripped due to a loss of offsite power.
Operators are maintaining RCS cold leg temperatures and SG levels constant.
Which of the following statements is true?
- a. Actual RCS flow is higher than it was 30 minutes ago.
- b. Pressurizer heaters are insufficient to maintain RCS subcooling.
- c. CST levels are currently lowering at a slower rate than compared to 30 minutes ago.
- d. Core Exit Thermocouple temperatures are at the saturation temperature for the SG pressures.
REACTOR OPERATOR Page 12 of 102 Question #
012 Given the following conditions:
Unit 1 is at 100% power.
47018-0501, SAFEGUARD LOGIC TRAIN A DC FAILURE, alarms.
47024-1003, D1 EMERGENCY GENERATOR LOSS OF CONTROL VOLTAGE, alarms.
47024-1102, 11 DC SYSTEM TROUBLE, alarms.
47024-1201, 11 DC PANEL UNDERVOLTAGE, alarms.
The Unit 1 Reactor will _______ and D1 will ________.
- a. remain at power lose control power
- b. remain at power auto start but the field will not flash
- c. trip NOT auto start and auto fuel oil transfer is lost.
- d. trip auto start and the field may flash due to residual magnetic flux. Fuel oil transfer still works in automatic.
REACTOR OPERATOR Page 13 of 102 Question #
013 Which of the following Cooling Water inlet temperatures is the HIGHEST that would NOT result in declaring safety systems inoperable?
- a. 79°F
- b. 84°F
- c. 89°F
- d. 94°F
REACTOR OPERATOR Page 14 of 102 Question #
014 Given the following conditions:
- 121 & 122 air compressors are running in PREFERRED.
- 123 air compressor is in FIRST STANDBY.
- 124 air compressor is running in PREFERRED.
- 125 air compressor is in STANDBY.
Unit 1 Instrument Air Header pressure rapidly drops to <75 psig.
In response, ____ air compressor will start AND _____________________________.
- d. 125 CV-31740 and CV-31741, 1 RX BLDG INSTR AIR ISOL CV, CLOSE
REACTOR OPERATOR Page 15 of 102 Question #
015 Given the following alarms:
- 47515-0509, REGEN HX LTDN LINE HI TEMP (395°F)
- 47515-0505, VOLUME CONTROL TANK HI/LO LVL (8%)
- 47515-0206, 21 RCP LABYRINTH SEAL LO P (14 H2O)
- 47515-0206, 22 RCP LABYRINTH SEAL LO P (14 H2O)
- 47512-0507, PRESSURIZER LEVEL DEVIATION (+/-10%)
- 47515-0203, CHARGING PUMP IN AUTO TROUBLE
- 47019-0603, AUX BLDG SUMP HI LVL WHUT level increasing on Recorder 53009, 121 ARTD/NON-ARTD SUMP TNKS LVL RCDR Which of the following is the cause of the alarms?
- a. Charging line leak outside containment
- b. Letdown line leak outside containment
- c. Charging line leak inside containment
- d. RCP seal failure
REACTOR OPERATOR Page 16 of 102 Question #
016 Given the following conditions:
1ECA-1.1, Loss of Emergency Coolant Recirculation, Step 5, given below, is being performed.
Containment pressure is 29 psig and lowering.
One RHR pump is injecting from the RWST.
RWST level is 42% and lowering.
ALL CFCUs are running in safeguards mode.
REACTOR OPERATOR Page 17 of 102 Question #
016 continued. See previous page for additional conditions At the completion of Step 5, ______ Containment Spray Pump(s) will be running because the operator ____________________________.
- a. NO stopped BOTH running Containment Spray Pumps
- b. ONE stopped ONE Containment Spray Pump
- c. ONE started ONE Containment Spray Pump
- d. TWO took NO action
REACTOR OPERATOR Page 18 of 102 Question #
017 Given the following conditions:
Unit 1 was at 100% power when a reactor trip and safety injection occurred The crew has transitioned to 1FR-H.1, Response to Loss of Secondary Heat Sink While attempting to restore AFW, the following conditions are noted:
o 47010-0107, 12 AFWP LOCKOUT, is in alarm.
o 11 SG pressure is 75 psig and lowering.
o 12 SG pressure is 800 psig and slowly lowering.
o CST levels are 100,000 gallons each.
Which cause below explains the above indications AND will allow a restart of 12 AFWP from the control room per the Alarm Response Procedure?
- a. Bus Load Rejection
- b. Electrical overcurrent trip
- c. Low suction pressure trip
- d. Low discharge pressure trip
REACTOR OPERATOR Page 19 of 102 Question #
018 Given the following conditions:
Both Units were operating at 100% power.
2RX transformer was taken out of service due to an oil leak.
C20.3 AOP4, Electrical Power System Operating Restrictions and Limitations Loss of 2RX Transformer, actions for removing 2RX from service are complete.
Unit 1 trips.
Which of the following correctly shows the power supplies to the listed buses?
Bus 11 Bus 12 Bus 21 Bus 22
- a.
1RX 1RX 2M 2M
- b.
de-energized de-energized 2M 2M
- c.
1RY 1RY 2RY 2RY
- d.
de-energized de-energized 1RX 1RX
REACTOR OPERATOR Page 20 of 102 Question #
019 Given the following conditions:
Charging is aligned normally.
1ES-0.1, Reactor Trip Recovery, is in progress.
A boration is required due to multiple control rods failing to insert during the reactor trip.
A Manual boration at the MAXIMUM flowrate for current conditions is to be performed.
Of the positions indicated in the picture, controller OUTPUT will be set to __________ to achieve the MAXIMUM allowed boric acid flowrate under the present conditions.
ACTUAL boric acid flowrate will _____ over the course of the boration.
- a. position a lower
- b. position b rise
- c. position c rise
- d. position d lower
REACTOR OPERATOR Page 21 of 102 Question #
020 Given the following conditions:
Unit 1 is at 100% power.
11 Charging pump is running in Automatic.
12 Charging pump is running in Manual.
1LI427, PRZR LEVEL, is 15% and rising.
1FI134, LETDOWN HX OUTLET FLOW, reads 0 GPM.
No operator actions have occurred.
Which one of the following would have resulted in the above conditions?
- a. The charging pump controller has failed high.
- b. The controlling Pressurizer Level channel has failed high.
- c. Instrument air was lost to CV-31328, Regen HX CHG Line OUTL.
- d. The control power fuse for CV-31226, Letdown Line ISOL, has blown.
REACTOR OPERATOR Page 22 of 102 Question #
021 Given the following conditions:
Unit 2 was performing a reactor startup per 2C1.2, Unit 2 Startup Procedure.
N35, Intermediate Range Nuclear Instrument, reads 2 x 10-10 amps N36, Intermediate Range Nuclear Instrument, reads 3 x 10-10 amps.
The Permissive P-6 is actuated, but SR trips have NOT been blocked.
Proper SR/IR overlap has just been verified.
N31, Source Range Nuclear Instrument, has just failed low.
Unit 2 Tech Specs _______ met. The crew will _________________________________.
- a. are NOT trip the reactor and implement 2E-0, Reactor Trip or Safety Injection
- b. are NOT fully insert control rods to maintain the reactor subcritical
- c. are suspend any positive reactivity changes until N31 is repaired
- d. are block the SR trips and continue the reactor startup
REACTOR OPERATOR Page 23 of 102 Question #
022 Given the following conditions:
Unit 1 was at 100% power.
47013-0502, N35 INTERMEDIATE RANGE LOSS OF COMP VOLT, alarms.
Unit 1 Reactor tripped.
No operator actions have occurred.
Which of the following describes the response of the Source Range Detectors?
- a. BOTH N31 and N32 will automatically energize EARLIER than expected after a reactor trip.
- b. ONLY N31 Source Range Detector will automatically energize at a HIGHER power level on decreasing power.
- c. BOTH N31 and N32 Source Range Detectors will FAIL to automatically energize on a reactor trip.
- d. ONLY N32 Source Range Detector will FAIL to automatically energize on decreasing power.
REACTOR OPERATOR Page 24 of 102 Question #
023 Given the following conditions:
A fuel handling accident has occurred in the Spent Fuel Pool.
R-25, Spent Fuel Pool Air Monitor A, is in alarm.
R-31, Spent Fuel Pool Air Monitor B, is in alarm.
NO operator actions have occurred.
121 Spent Fuel Pool Normal Exhaust Fan is ____.
121 Spent Fuel Special & 11 In-Service Purge Exhaust Fans are ____.
122 Spent Fuel Special & 21 In-Service Purge Exhaust Fans are ____.
- a. on off off
- b. off on off
- c. off on on
- d. off off on
REACTOR OPERATOR Page 25 of 102 Question #
024 Given the following conditions:
A Steam Generator Tube Rupture has occurred on Unit 2.
Ruptured SG level has returned in the narrow range (>5% NR).
The SS directs all feed flow to the ruptured SG stopped.
Terminating Feedwater flow to the ruptured SG...
- a. prevents an unnecessary transition to FR-H.1.
- b. minimizes the possibility of steam generator overfill.
- c. promotes thermal stratification and prevents SG tubes from coming in contact with the ruptured SG steam space.
- d. reduces the radioactive release rate by "filtering the release" through a layer of water prior to it escaping to the atmosphere.
REACTOR OPERATOR Page 26 of 102 Question #
025 Given the following conditions:
A release of liquid waste is in progress.
R-18, Waste Disposal Liquid Effluent Monitor, alarms.
What automatic action(s) occur?
- a. CV-31465, 11 SGB FLASH TNK RIVER DISCH ISOL CV, closes.
- b. CV-31256, R-18 WST DISP SYS LIQ EFFL MON ISOL CV, closes.
- d. CV-31519 and CV-31607, 11 and 21 SGB FLASH TNK TO RIVER FLOW CV, close.
REACTOR OPERATOR Page 27 of 102 Question #
026 Given the following conditions:
A release of 121 and 125 Waste Gas Decay Tanks is in progress.
The radioactivity content of these tanks is 1000 times higher than expected.
2R-30, Unit 2 Aux Building Vent Gas Monitor, is in high alarm.
The operators are verifying automatic actions per the ARP.
Which of the following actions will occur automatically to stop the gaseous radwaste release?
- a. 122 Aux Building Special Ventilation starts.
- b. 121 and 122 Sample Room exhaust fans stop.
- c. CV-31271, GAS DCY TNKS TO PLNT VNT, closes.
- d. Laundry, Locker, and Filter Room ventilation exhaust fans stop.
REACTOR OPERATOR Page 28 of 102 Question #
027 Given the following conditions:
Both units are operating at 100% power.
R-1, Control Room Area Radiation Monitor, alarms What automatic action(s), if any, occur?
- a. There are NO automatic actions.
- b. ONLY the Unit 1 Outside Air Supply Damper will CLOSE.
- c. ONLY the PAC Filter Outside Air Supply Damper will CLOSE.
- d. BOTH Unit 1 and Unit 2 Outside Air Supply Dampers will CLOSE.
REACTOR OPERATOR Page 29 of 102 Question #
028 Given the following conditions:
Unit 1 was at 5% power.
47006-0101, 1R RESERVE AUX XFMR SUDDEN PRESS TRIP, alarms.
Bus 15 and 16 are powered from their respective diesels.
AMSAC/DSS was in AUTO.
With the above conditions, ______ Unit 1 Reactor Coolant pump(s) are running and Control Rods will drop to the bottom of the core due to ___________________________.
- a. both 11 STM GEN LO-LO Reactor Trip
- b. one One Loop LO Flow or RCP BKR Open Reactor Trip
- c. NO AMSAC/DSS actuation
- d. NO 11 STM GEN LO-LO Reactor Trip
REACTOR OPERATOR Page 30 of 102 Question #
029 Given the following conditions:
Unit 1 Main Generator Load 600MW and rising 1RX and 1RY winding voltages 3300VAC 1MX and 1MY winding voltages 3300VAC RCS Flow 95%
Which of the following is the correct next action?
- a. Manually trip the Unit 1 Reactor.
- b. Manually start D1 and D2 EDGs.
- c. Continue to closely monitor parameters.
- d. Reduce load to prevent overpowering the Unit 1 Reactor.
REACTOR OPERATOR Page 31 of 102 Question #
030 Given the following conditions:
Unit 1 was at 100% power.
RCS Boron Concentration was 450 ppm.
HC-110, BA To Blender Flow Cont, was in AUTO and set to 10%.
HC-111, RX M-U WTR to Blender Flow Cont, was in AUTO and set to 45%.
The rack mounted controller HFC-111, Reactor Makeup Water Flow, failed to MINIMUM output.
An auto make-up to the VCT has just occurred.
No operator action occurred.
Figure 1, Blended Flow Nomograph, from C12.5, Boron Concentration Control, is provided.
Blended flow will be _______ ppm Boron and RCS TAVG will _________.
- a. 95 rise
- b. 450 remain constant
- c. 800 lower
- d. 3250 lower
REACTOR OPERATOR Page 32 of 102 Question #
031 Given the following conditions:
Unit 1 is stabilized at 1X10-8 amps by IRNIs to collect critical data.
1C1.2, Unit 1 Startup Procedure, is in progress.
Reactor Power begins to rise.
ITC is negative.
The power rise is the result of ___________________________ and can be confirmed by observing ____________________________.
- b. a leak in the Seal Water Heat Exchanger tubes CC surge tank level
- d. the Letdown Heat Exchanger TCV M/A station failing to 0% output Letdown HX outlet temperature and pressure
REACTOR OPERATOR Page 33 of 102 Question #
032 Given the following conditions:
Unit 1 is currently in a refueling outage.
PNL 114 Inst Bus IV (Yellow) was lost earlier in the shift.
1C15 AOP 3, RHR Operation Without Control Room Instrumentation or Flow Control, has been implemented The A RHR Train is in Phase II cooling.
The B RHR Train is in Standby.
To LOWER RCS temperature, OUTPUT will be ____(1)____ on ____(2)____; Total RHR flow is maintained less than 2000 GPM by ____(3)____ OUTPUT on ____(4)____.
____(1)____
____(2)____
____(3)____
____(4)____
REACTOR OPERATOR Page 34 of 102 Question #
033 Given the following conditions:
A RED path condition exists on the Core Cooling status tree.
Attempts to restore ECCS flow to the RCS have NOT been successful.
The next required action is depressurization of the SGs.
The SGs must be depressurized RAPIDLY to...
- a. prevent pressurized thermal shock of the reactor vessel.
- c. establish conditions for starting RCPs.
- d. enable ECCS flow.
REACTOR OPERATOR Page 35 of 102 Question #
034 Given the following conditions:
Unit 1 is at 100% power.
A Loop SI Accumulator was inadvertently completely drained to the RCDT.
Simultaneously the following occurs:
o A Loss of Off-Site Power occurs.
o B Loops cold leg suffers a double ended guillotine shear on Unit 1.
D1 and D2 sequence onto Bus 15 and Bus 16 respectively.
PRIOR to SI pump injection, which of the following is true concerning Unit 1?
- a. ECCS water will refill the reactor vessel to the nozzles.
- b. The core can be assumed to remain covered during this time.
- c. No core cooling is assumed to occur from the ECCS during this time.
- d. ECCS water will fill the volume outside the core barrel, the bottom plenum and about 1/2 the core.
REACTOR OPERATOR Page 36 of 102 Question #
035 Given the following conditions:
Unit 1 is operating at 100% power.
47012-0406, PRZR RELIEF TANK HI TEMP/LVL/PRESS OR LO LVL, alarms.
Current PRT conditions are as follows:
o Level 80% and rising o Pressure 11 PSIG and rising o Temperature 100°F and stable The source of PRT in-leakage is the...
AND the PRT...
REACTOR OPERATOR Page 37 of 102 Question #
036 Given the following conditions:
Both Units are at 100% power.
Bus 25 locks out.
Which one of the following correctly describes the effect of the loss of Bus 25?
- a. The 121 Control Room Ventilation Cleanup fan will fail to start on an SI signal.
- b. The 123 Instrument Air Compressor starts on low Instrument Air pressure.
- c. The 22 Component Cooling pump auto started on low discharge pressure.
- d. The 121 Cooling Water Pump auto started on low CL pressure.
REACTOR OPERATOR Page 38 of 102 Question #
037 Given the following conditions:
Unit 1 is in mode 3.
RCS is at normal operating temperature and pressure.
The Aux Building APEO is performing a clearance order on the 11 Accumulator.
Engineers are walking down containment for closeout inspections.
One Pressurizer safety fails open.
What action should be taken NEXT?
- a. Evacuate containment to control personal exposure.
- c. Direct personnel in containment to open RC-22-1, Aux PRT vent to prevent PRT rupture disc failure.
- d. Direct personnel in containment to close the Pressurizer safety manual isolation valve to attempt to reseat the safety valve.
REACTOR OPERATOR Page 39 of 102 Question #
038 Given the following conditions:
Unit 1 is at 18% power.
1PT-431, Blue Channel Pressurizer pressure, failed.
All associated protective bistables have been tripped.
Pressurizer Pressure Control has been returned to automatic.
An instrument failure then results in a Unit 1 reactor trip.
Which of the following instrument failures caused the Unit 1 reactor trip?
- a. PT-485, Turbine 1st Stage Pressure, failed HIGH.
- b. Thot, Red Channel, failed HIGH.
- c. Tcold, Red Channel, failed HIGH.
- d. N-35, IR Nuclear Instrument, failed HIGH.
REACTOR OPERATOR Page 40 of 102 Question #
039 Given the following conditions:
Unit 1 is in Mode 3.
11 TD AFW pump is in SHUTDOWN AUTO and NOT running.
12 MD AFW pump is in SHUTDOWN AUTO and NOT running.
AMSAC/DSS is BLOCKED.
11 and 12 SG NR levels are 35%.
11 MFP is running.
11 TD AFW pump starts.
11 TD AFW pump started AUTOMATICALLY due to...
- a. undervoltage on Bus 11 AND Bus 12.
- b. placing 11 TD AFW pump in AUTO.
- c. unblocking AMSAC/DSS.
- d. 11 MFP tripping.
REACTOR OPERATOR Page 41 of 102 Question #
040 Given the following conditions:
Unit 1 tripped due to a Main Steam Line Break.
The following Step of 1E-0, Attachment L: SI Alignment Verification, is in progress.
The 13 CNTNMT FAN COIL RUNNING SI active status light is NOT lit.
What action, if any, is required?
- a. Place the 13 CFCU discharge to containment dome/auto/gap CS to the DOME position, and verify proper damper alignment.
- b. If the MSLB is outside of containment, the SI Active light for the 13 CFCU is not required to be lit and no further alignment is required.
- c. Place the Train A Cooling Water/Chilled Water valves control switch in the ISOLATE position and check the green and blue lights on.
- d. Place any closed Cooling Water MVs associated with the 13 CFCU in the OPEN position and verify the 13 CFCU is running in slow speed.
REACTOR OPERATOR Page 42 of 102 Question #
041 Which of the following Engineered Safety Features Actuation System signals is NOT AUTOMATICALLY generated upon any Safety Injection signal AND IS designed to prevent containment from exceeding its design limits?
- b. Containment Isolation
- c. Main Steam Line Isolation
- d. Containment Ventilation Isolation
REACTOR OPERATOR Page 43 of 102 Question #
042 Given the following conditions:
A Design Basis LOCA occurred on Unit 1.
Containment Pressure will remain below the design limit of ________________________.
The Containment Fan Coil Unit(s) must be running in SLOW to the DOME to __________.
- a. 23 psig, if ALL 4 Containment Fan Coil Units are running prevent the discharge of the fans from interfering with the operation of the Containment Spray System
- b. 23 psig, if 2 Containment Fan Coil Units are running prevent stalling under the high density atmospheric conditions in the Containment
- c. 46 psig, if 1 Containment Spray Pump AND 1 Containment Fan Coil Unit are running prevent the discharge of the fan from interfering with the operation of the Containment Spray System
- d. 46 psig, if 1 Containment Spray Pump AND 2 Containment Fan Coil Units are running prevent stalling under the high density atmospheric conditions in the Containment
REACTOR OPERATOR Page 44 of 102 Question #
043 Given the following conditions:
Unit 1 is at 12% power.
ITC is positive.
An INCREASE in steam demand causes a _______ reactivity addition.
The turbine should be maintained in ______ mode to ensure the plant will stabilize at a lower RCS temperature.
- a. negative VPC
- b. negative FSP
- c. positive VPC
- d. positive FSP
REACTOR OPERATOR Page 45 of 102 Question #
044 Given the following conditions:
Unit 1 is at 70% power.
A rupture of the main feedwater system occurs inside containment UPSTREAM of the check valve.
BOTH Main Feed Water Pumps will be tripped by a __________________.
Entry conditions for ________________________ are met.
- a. low-low steam generator level reactor trip 1E-0 followed by 1ES-0.1, Reactor Trip Recovery,
- c. low steam generator pressure safeguards actuation 1E-0 followed by 1ES-0.2, SI Termination,
- d. SGWLC system high steam flow/feed flow mismatch 1C1.4 AOP 1, Rapid Power Reduction Unit 1,
REACTOR OPERATOR Page 46 of 102 Question #
045 Which one of the following is NOT a possible Auxiliary Feedwater flowpath to the 11 SG?
REACTOR OPERATOR Page 47 of 102 Question #
046 Given the following conditions:
Unit 1 was at 100% power for 100 days.
Unit 1 tripped and 1E-0, Reactor Trip or Safety Injection, was entered.
Procedurally, AFW flow must be maintained at least _____ GPM with 1000 psig discharge pressure in order to ensure ____________________________.
- a. 160 Steam Generator tube integrity is maintained
- b. 185 cooldown does not exceed 100°F/hr
- c. 200 adequate decay heat removal
- d. 225 adequate decay heat removal plus cooldown flow
REACTOR OPERATOR Page 48 of 102 Question #
047 The fire brigade is composed of:
The ____________(1)____________ acting as the Fire Brigade Chief.
A total of ___(2)___ fire brigade members, but NOT including the _(3)_ members of the minimum shift crew for safe shutdown of the reactors.
(1) _
(2) _
(3) _
- a. Unit 1 Turbine Building APEO 5
6
- b. Unaffected unit shift supervisor 5
6
- c. Unit 1 Turbine Building APEO 7
5
- d. Unaffected unit shift supervisor 7
5
REACTOR OPERATOR Page 49 of 102 Question #
048 Given the following conditions:
Unit 1 was at 100% power.
47018-0501, SAFEGUARD LOGIC TRAIN A DC FAILURE, alarms.
47024-1003, D1 EMERGENCY GENERATOR LOSS OF CONTROL VOLTAGE, alarms.
47024-1102, 11 DC SYSTEM TROUBLE, alarms.
47024-1201, 11 DC PANEL UNDERVOLTAGE, alarms.
As a result, _____________________ and ____________________.
- a. 11 Turbine Driven AFW Pump STARTS Non-Safeguards buses 11, 12, 13 and 14 de-energize
- b. 11 Turbine Driven AFW Pump STARTS Buses 11 and 12 AUTOMATICALLY transfer control power to DC Panel 21
- c. Main Generator Output Breaker AUTOMATICALLY TRIPS Non-Safeguards buses 11, 12, 13 and 14 de-energize
- d. Main Generator Output Breaker AUTOMATICALLY TRIPS Buses 11 and 12 AUTOMATICALLY transfer control power to DC Panel 21
REACTOR OPERATOR Page 50 of 102 Question #
049 Given the following conditions:
Unit 1 is at 100% power.
SP 1093, D1 Diesel Generator Monthly Slow Start Test, is in progress.
D2 is in its normal standby mode.
While unloading D1, the "Motoring Current" relay actuates.
PRIOR to any operator action, a Loss of Offsite Power occurs CONCURRENTLY with an automatic Safety Injection actuation.
No operator actions have taken place.
D1 will...
- a. stop AND not restart.
- b. continue to run unloaded.
- c. stop, restart, and run unloaded.
- d. continue to run AND will re-power Bus 15.
REACTOR OPERATOR Page 51 of 102 Question #
050 Given the following conditions:
T is 100%.
OTT setpoint is 110%.
Pressurizer pressure is decreasing due to a small Reactor Coolant System leak.
Which one of the following responses describes the initial response of the OTT setpoint relative to actual T?
- a. Actual T increases and the setpoint decreases causing the difference between setpoint and actual T to increase.
- b. Actual T decreases and the setpoint increases causing the difference between setpoint and actual T to decrease.
- c. Setpoint increases causing the difference between the setpoint and actual T to increase.
- d. Setpoint decreases causing the difference between the setpoint and actual T to decrease.
REACTOR OPERATOR Page 52 of 102 Question #
051 Given the following conditions:
Unit 1 Gas Decay Tank #127 is being released to the atmosphere.
Cooling Towers are in operation.
Wind direction is coming from 30°.
Wind speed is 13 mph and stable.
C21.3-10.7, Releasing Radioactive Gas from 127 Low Level Decay Tank, is provided.
What action will be taken and why?
- a. Continue to monitor the release, parameters are acceptable.
- b. Stop the release until the wind speed becomes favorable.
- c. Stop the release until the wind direction becomes favorable.
- d. Stop the release until wind speed AND direction becomes favorable.
REACTOR OPERATOR Page 53 of 102 Question #
052 Given the following conditions:
Unit 1 has tripped and SI has actuated.
The slave relays for the SI actuation of the Cooling Water system Train B have failed to operate.
All other systems respond normally.
No Operator actions have been taken.
What is the status of 12 Component Cooling Water Heat Exchanger?
- a. There is NO cooling water flow through the heat exchanger.
- b. The outlet FCV strokes open but open travel is limited by the travel stop, and the valve does not modulate based on temperature.
- c. The outlet FCV opens to control temperature and is NOT limited by the travel stop in opening.
- d. The outlet FCV opens to control temperature but maximum open position is limited by the travel stop.
REACTOR OPERATOR Page 54 of 102 Question #
053 Given the following conditions:
Both Units are operating at 100% power.
An inadvertent SI Train A and Train B initiates on Unit 2.
What is the status of the Cooling Water System after the SI signal?
- a. MV-32036 and MV-32037 - SHUT MV-32034 and MV-32035 - SHUT
- b. MV-32036 and MV-32037 - SHUT MV-32034 and MV-32035 - OPEN
- c. MV-32036 and MV-32037 - OPEN MV-32034 and MV-32035 - SHUT
- d. MV-32036 and MV-32037 - OPEN MV-32034 and MV-32035 - OPEN
REACTOR OPERATOR Page 55 of 102 Question#
054 Given the following conditions:
There is a leak on Unit 2 Instrument Air to Containment.
A Instrument Air Header Pressure dropped to 73 psig.
B Instrument Air Header Pressure dropped to 74 psig.
Unit 2 Instrument Air pressure continues to lower.
Unit 1 Instrument Air pressure is rising.
Which of the following could jeopardize the UNIT 1 instrument air supply?
- d. Closing CP-40-7, STATION AIR RECEIVE X-CONN TO INSTRUMENT AIR.
REACTOR OPERATOR Page 56 of 102 Question #
055 Given the following conditions:
A Safety Injection occurred on Unit 1.
Containment pressure is 5 psig.
No operator actions have occurred.
To open Containment Isolation valves under these conditions:
Containment Pressure ________ required to be reduced below 3.5 psig.
________ reset pushbuttons are required to be depressed.
- a. is NOT ONLY SI
- b. is NOT SI AND CI
- c. is ONLY CI
- d. is SI AND CI
REACTOR OPERATOR Page 57 of 102 Question #
056 Given the following conditions:
Unit 1 has just started up, following a refueling outage.
Unit 1 Main turbine load is 60 MWe.
Tave is 547°F.
Nuclear Instruments read as follows:
o N41 = 10%
o N42 = 9%
o N43 = 8%
o N44 = 9%
The Rod Control Selector switch is in AUTO.
Steam Dumps are in STM PRESS mode.
The Steam Dump controller is set to 1050 PSIG.
If the Main Generator trips...
- a. rods will not move.
- b. rods will ONLY step IN.
- c. rods will step IN, then OUT.
- d. the Reactor trips automatically.
REACTOR OPERATOR Page 58 of 102 Question #
057 Given the following conditions:
1ES-0.1, Reactor Trip Recovery, is in progress.
11 and 12 RCPs are NOT running.
11 and 12 SG pressures are 916 psig.
RCS Parameters are as follows:
o Cold leg temperatures are 536°F.
o Hot leg temperatures are 563°F.
o Pressure is 2181 psig.
Natural Circulation is ________________.
To increase/initiate natural circulation flow, the operators will __________ SG pressure.
- a. occurring lower
- b. occurring raise
- c. NOT occurring lower
- d. NOT occurring raise
REACTOR OPERATOR Page 59 of 102 Question #
058 Given the following conditions:
A Small break LOCA has occurred on Unit 1.
Both RCPs have been tripped.
Subcooling is 0°F.
ALL Pressurizer level indication has FAILED.
The crew will be unable to...
- a. terminate SI, when required.
- b. quantify the actual RCS leak rate.
- c. determine if water has passed through the PRZR safeties.
- d. determine if the conditions necessary for natural circulation exist.
REACTOR OPERATOR Page 60 of 102 Question #
059 Given the following conditions:
Unit 1 is at 8% power during a plant startup.
Vital instrument bus 111 (White bus) is mistakenly shifted to the Alternate AC Power source, Panel 117.
Which of the following describes the resulting plant response and reason?
- a. The reactor does NOT trip because power is above P-6.
- b. The reactor does NOT trip because power is still below P-10.
- c. A reactor trip occurs because IRNI channel N36 momentarily de-energizes.
- d. A reactor trip occurs because PRNI channel N41 momentarily de-energizes.
REACTOR OPERATOR Page 61 of 102 Question #
060 Given the following conditions:
Unit 1 is at 100% power.
Steam Dumps are in Tavg Mode.
TE-404A, RCS Loop Thot Transmitter, fails HIGH.
Unit 1 reactor trips.
No operator actions are taken.
At what temperature will the RCS stabilize?
- a. 540°F
- b. 547°F
- c. 550°F
- d. 552°F
REACTOR OPERATOR Page 62 of 102 Question #
061 Given the following conditions:
Unit 1 is at 100% power.
11 & 12 Condensate Pumps are running.
BKR 14-6, 12 CD Pump, fails OPEN.
The lowest condensate pump discharge pressure seen is 250 psig.
__(1)__ Condensate pump(s) will be running.
__(2)__ Feedwater pump will be running.
A Reactor Trip __(3)__ required.
___(1)___
___(2)___
___(3)___
- a.
11 11 is NOT
- b.
11 12 is
- c.
11 and 13 11 is NOT
- d.
11 and 13 12 is
REACTOR OPERATOR Page 63 of 102 Question #
062 Given the following conditions:
Unit 1 is at 100% power.
11 SI Accumulator level is being lowered.
CV-31443, 11 ACCUM TO RC DRN TNK, is OPEN.
11 RCDT level is steady with 11 RCDT Pump running.
An inadvertent SI occurs on Unit 1.
NO operator action occurs.
RCDT level ____________, because the ______________________________.
- a. rises RCDT Pump discharge valves shut
- b. rises PRT drain valve automatically opens
- c. lowers RCDT Pump discharge valves stay open
- d. lowers SI Accumulator is automatically isolated from the RCDT
REACTOR OPERATOR Page 64 of 102 Question #
063 Given the following conditions:
The Aux Building APEO is in the Control Room (CR).
The on-line WGDT pressure is 110 psig and rising.
Which of the following indicates that WGDT swap-over has occurred?
- a. 47015-0603, RAD WASTE BLDG LOCAL ALARM.
- b. 47015-0503, LIQUID WASTE DISPOSAL LOCAL ALARM.
- c. 47015-0101, WASTE DISPOSAL BORON RECYCLE LOCAL ALARM.
REACTOR OPERATOR Page 65 of 102 Question #
064 Given the following conditions:
Unidentified leakage determined by SP 1001AA, Daily Reactor Coolant System Leakage Test, has been rising.
1R-7, U-1 In-Core Seal Table Area, has just alarmed.
Pressurizer Level is on program and stable.
Entry Conditions are met for _______________________________.
- a. 1E-0, Reactor Trip or Safety Injection
- b. 1C4 AOP1, Reactor Coolant Leakage
- c. 1C4 AOP2, Steam Generator Tube Leak
- d. 1C14 AOP2, Leakage Into the Component Cooling System
REACTOR OPERATOR Page 66 of 102 Question #
065 The Emergency Intake Bay is backwashed by using water from the discharge of the...
- a. Cooling Water pumps.
- b. Deicing Water pumps.
- c. Cooling Tower pump 121 or 122.
- d. Circulating Water pumps 12 and 21.
REACTOR OPERATOR Page 67 of 102 Question #
066 In accordance with SWI O-10, Operations Manual Usage, while performing abnormal or emergency procedures, the Reactor Operator SHALL perform __(1)__ from memory, until ___(2)___.
_____________(1)_____________
_______________(2)________________
- a. immediate operator actions the SS has obtained the appropriate procedure, and is ready to use the procedure, beginning with step 1.
- b. continuous action steps the SS has found, and read aloud the particular continuous action steps.
- c. notes and/or cautions the SS has reached, and read aloud the particular note and/or caution.
- d. continuous action steps the SS has obtained the appropriate procedure, and is ready to use the procedure, beginning with step 1.
REACTOR OPERATOR Page 68 of 102 Question #
067 Given the following conditions:
Rod G-11 (CB-D) is at 172 steps.
All other control bank D rods are at 146 steps.
1C5 AOP5, Misaligned rod, Stuck Rod, and/or RPI Failure or Drift, is entered.
All control bank D rods have been determined to be OPERABLE.
Assume the turbine is operated as necessary to maintain Tave to Tref.
Procedurally, Rod G-11 will be aligned with Control Bank D by...
- a. alternating between insertion of rod G-11 and withdrawal of Control Bank D.
- b. maintaining rod G-11 stationary while withdrawing control bank D to 160 steps.
- c. inserting rod G-11 to 146 steps while maintaining all other rods in the control bank stationary.
- d. fully inserting all four control bank D rods into the core, then withdrawing them to their initial position.
REACTOR OPERATOR Page 69 of 102 Question #
068 Given the following conditions:
A power reduction at 2%/min per 1C1.4 AOP1, Rapid Power Reduction - Unit 1, is being performed due to degrading performance of 12 MFP.
Reactor Power is 90% when the 12 Main Feed Pump trips.
The SS directs the power reduction rate raised to 5%/min and continuation of the power reduction.
The RO will _____________________________________________________.
- a. adjust rate to 5%/min, but request a re-evaluation of the boration rate
- b. trip the reactor and enter 1E-0, Reactor Trip or Safety Injection
- c. continue the downpower at the briefed rate of 2%/min
- d. adjust rate to 5%/min AND manually open FRVs
REACTOR OPERATOR Page 70 of 102 Question #
069 Given the following conditions:
Unit 1 is at 100% power.
At 0735:
o SP 1001B, Unit 1 Control Room Logs - Modes 1 and 2, is completed satisfactorily.
At 0830:
o PRNI N43 removed from service for routine surveillance.
At 1230:
o PRNI N43 returned to service upon completion of routine surveillance.
At 1415:
o Parameters OUTSIDE the acceptance criteria for PRNI N43 are discovered during review of the routine surveillance paper work.
At 1545:
o Routine surveillance repeated and completed satisfactorily.
At 1935:
o SP 1001B, Unit 1 Control Room Logs - Modes 1 and 2, is completed satisfactorily.
T.S. LCO 3.3.1 Condition D requires 4 channels of PRNI.
The time clock for T.S. LCO 3.3.1, Condition D required action started at...
- a. 0730 and ran until 1230; restarted at 1415 and ran until 1545.
- b. 0735 and runs until 1545.
- c. 0830 and ran until 1230; restarted at 1415 and ran until 1935.
- d. 0830 and runs until 1545.
REACTOR OPERATOR Page 71 of 102 Question #
070 Given the following conditions:
47016-0204, 11 RWST Level Low, has alarmed 15 times in the past minute.
RWST Level has been verified at 92%.
The SS has authorized disabling of the alarm.
Which of the following are required to track the DISABLED Control Room Annunciator?
- a. Annunciator Out of Service Record Sheet completed, Operations Turnover Log, AND OOS Sticker Placed on Annunciator.
- b. Annunciator Out of Service Record Sheet completed, Operations Turnover Log, AND Top 10 Equipment List.
- c. Annunciator Out of Service Record Sheet completed, Top 10 Equipment List, AND OOS Sticker Placed on Annunciator.
- d. Top 10 Equipment List, Operations Turnover Log, AND OOS Sticker Placed on Annunciator.
REACTOR OPERATOR Page 72 of 102 Question #
071 Which of the following radiation monitors can NOT be used to detect primary to secondary leakage?
- a. 1R-9, RC LETDN LINE R UNIT 1
- b. 1R-15, CDSR AIR EJCTR GAS RADIOACTIVITY
REACTOR OPERATOR Page 73 of 102 Question #
072 Given the following conditions:
Unit 2 is at 100% power.
Flux mapping is in progress.
A small leak has developed in the Unit 2 RCS.
Unit 2 SS has directed two operators to perform a containment entry to investigate.
Containment entry is...
- a. allowed IF accompanied by a qualified RP specialist.
- b. allowed WITH Radiation Protection Manager approval.
- c. NOT allowed, because a worker safety review was not completed.
- d. NOT allowed, because flux mapping is in progress with the reactor critical.
REACTOR OPERATOR Page 74 of 102 Question #
073 Given the following conditions:
While using the Portal Monitor at the Security Access Facility the Portal Monitor alarms.
Prior to exiting the site, Radiation Protection will be notified AND...
- a. is required to perform a personnel decontamination.
- b. TWO additional scans, with no contamination detected, are required to be performed at Access Control using the Two Step Monitor.
- c. ONE additional scan, with no contamination detected, is required to be performed at the Security Access Facility using the Portal Monitor.
- d. TWO additional scans, with no contamination detected, are required to be performed at the Security Access Facility using the Portal Monitor.
REACTOR OPERATOR Page 75 of 102 Question #
074 Given the following conditions:
Unit 1 was at 100%.
A valid Reactor Trip signal due to a Dropped Rod occurred.
The Reactor Operator has operated both Manual Trip Switches and the AMSAC/DSS switch The following indications exist:
o Reactor Trip Breakers
'A' is closed
'B' is open o IR Neutron flux slowly increasing o IR SUR slightly positive o RPIs All Zero o Rod Bottom Lights NOT lit o Reactor Power 6%
o Bus 15 0 volts o Bus 16 0 volts What is required NEXT?
- b. Transition to 1FR-S.1, Response to Nuclear Power Generation/ATWS.
- c. Continue in 1E-0, Reactor Trip or Safety Injection, verifying turbine trip.
- d. Perform 1C20.5 AOP1(2), Re-energizing 4.16KV Bus 15(16), to restore power to one of the safeguards buses.
REACTOR OPERATOR Page 76 of 102 Question #
075 Per SWI-O-10, Operations Manual Usage, which of the following correctly describes when an emergency procedure action on the Information Page is applicable?
- a. PRIOR to performing the applicable step in the main body of the procedure.
- b. ANY time during the applicable procedure performance, following the completion of any applicable immediate action steps.
- c. AFTER proceeding PAST the applicable step in the main body of the procedure, AND it MAY apply after a transition is made to another procedure.
- d. AFTER proceeding PAST the applicable step in the main body of the procedure, BUT it will NEVER apply after a transition is made to another procedure.
SENIOR REACTOR OPERATOR Page 77 of 102 Question #
076 Given the following conditions:
Unit 1 is at 100% Power.
A.45 GPM leak rate was determined by SP 1001AA, Daily Reactor Coolant System Leakage Test.
SP 1001AAA, Reactor Coolant Leakage Investigation, has been initiated.
The leak is determined to be at the Spray Line weld connection to the Pressurizer.
ALL leakage is collecting in Sump A.
No other equipment is impacted.
Currently
- a. RCS unidentified leakage exceeds limits.
- b. RCS pressure boundary leakage exceeds limits.
- c. RCS identified leakage not within limit for reasons other than pressure boundary leakage or primary to secondary leakage.
- d. RCS leakage is within limits; continue to monitor to ensure the leakage does not interfere with RCS leakage detection systems.
SENIOR REACTOR OPERATOR Page 78 of 102 Question #
077 Given the following conditions:
Unit 1 is at 100% power.
Both 11 and 12 RCPs were secured due to loss of seal cooling.
1ES-3.1, POST-SGTR Cooldown Using Backfill, is in progress.
The TSC has just reported that a status evaluation for the loss of RCP seal cooling has been completed, and the 11 RCP may be started.
The step to depressurize the RCS to backfill from the ruptured SG is about to be performed.
The SS will...
- a. direct starting of 11 RCP per 1C3 AOP1, Post Accident Start of a RCP and use Normal Pressurizer Spray.
- b. use the Pressurizer PORV per 1ES-3.1 until 12 RCP becomes available and then use Normal Pressurizer Spray.
- c. direct starting of 11 RCP per 1C3 AOP1, Post Accident Start of a RCP and use Auxiliary Pressurizer Spray.
- d. use Auxiliary Pressurizer Spray per 1ES-3.1 until 12 RCP becomes available and then use Normal Pressurizer Spray.
SENIOR REACTOR OPERATOR Page 79 of 102 Question #
078 Given the following conditions:
Unit 1 is at 100% power.
A loss of ALL Main Feedwater occurs causing a reactor trip.
12 MD AFW Pump fails to start.
11 and 12 SG WR levels are 40%.
No operator actions have occurred.
47017: ________________________ Reactor Trip, will be flashing.
After leaving 1E-0, Reactor Trip or Safety Injection, the NEXT step the SS will direct to be performed is ____________________________________.
- a. 0102, PRZR HI PRESS 1FR-H.1, Response to Loss of Secondary Heat Sink, step 1
- b. 0102, PRZR HI PRESS 1ES-0.1, Reactor Trip Recovery, step 1
- d. 0304, 11 STM GEN LO-LO LVL 1ES-0.1, Reactor Trip Recovery, step 1
SENIOR REACTOR OPERATOR Page 80 of 102 Question #
079 Given the following conditions:
Both units are at 100% power.
TWO of the FOUR Bus 16 Degraded Voltage Function channels are INOPERABLE.
The Bus 16 Automatic Load Sequencer Function is INOPERABLE TS LCO 3.0.6, 3.3.4 and 3.8.1 are provided.
D2 is _____________;
LCO(s) _____________ is(are) NOT met; LCO 3.0.6 _____ applicable.
- a. OPERABLE 3.3.4 AND 3.8.1 is
- b. INOPERABLE 3.3.4 AND 3.8.1 is
- c. OPERABLE 3.3.4 is NOT
- d. INOPERABLE 3.8.1 is NOT
SENIOR REACTOR OPERATOR Page 81 of 102 Question #
080 Given the following conditions:
0100 - 12 DDCLP was placed OOS.
0200 - Bus 27 can NOT be aligned to Bus 25.
0300 - 21 Safeguards Screenhouse Exhaust Fan seizes.
0400 - 121 MDCLP is aligned to Train B Cooling Water Header.
0500 - 12 DDCLP is returned to service.
LCO 3.7.8 is provided.
LCO __________ was entered at _______ and exited at ________.
- a. 3.0.3 0300 0500
- b. 3.7.8 A 0200 0500
- c. 3.7.8 B 0300 0500
- d. 3.7.8 C 0400 0500
SENIOR REACTOR OPERATOR Page 82 of 102 Question #
081 Given the following conditions:
A transition from 1E-0, Reactor Trip or Safety Injection, to 1FR-C.2, Response to Degraded Core Cooling, occurred due to an ORANGE path on Core Cooling.
A RED path on Heat Sink occurs, directing performance of 1FR-H.1, Response to Loss of Secondary Heat Sink.
The SS is required to...
- d. complete all steps of 1FR-C.2, then transition to 1FR-H.1 only if the CFST for Core Cooling is satisfied.
SENIOR REACTOR OPERATOR Page 83 of 102 Question #
082 Given the following conditions:
Unit 1 core offload is in progress.
A fuel element has JUST been placed into the SFP upender.
Improper alignment of WGDT system results in a gaseous release into containment.
1R-12, U1 CNTM/SHLD BLD VENT GAS R, is in alarm and reading 120,000 cpm.
1R-22, U1 SHLD BLD STACK LO RNG R, is in alarm and reading 2,000 cpm.
The Containment SRO will perform _______________________________.
- a. C1.6 AOP1, Containment Evacuation
- b. D5.1 AOP1, SFP Area Evacuation - Non-Refueling
- c. D5.2 AOP1, Damaged Fuel Assembly
- d. D5.2 AOP4, Spent Fuel Pool Area Evacuation - Refueling
SENIOR REACTOR OPERATOR Page 84 of 102 Question #
083 Given the following conditions:
The Control Room has been evacuated due to a fire.
F5 Appendix B, Control Room Evacuation (Fire), is in progress.
The Unit 1 Shift Supervisor is performing Attachment I, Establish AFW Flow.
If AFWP suction pressure approaches 3 psi, the Unit 1 SS is required to...
- a. locally trip the TDAFWPs.
- b. refill the CSTs from the Condensate System.
- c. switch over to Cooling Water for AFWP suction.
- d. prepare to feed the Steam Generators from Main Feedwater.
SENIOR REACTOR OPERATOR Page 85 of 102 Question #
084 Given the following conditions:
SENIOR REACTOR OPERATOR Page 86 of 102 Question #
084 continued. See previous page for additional conditions At 10:10 am, Unit 2 SI and Reactor trip occurred.
At 10:35 am, Unit 2 SS transitioned to 2ECA-1.1, Loss of Emergency Coolant Recirculation, due to inability to isolate the leak outside containment At 10:50 am, 2ECA-1.1, Loss of Emergency Coolant Recirculation, Step 14.b RNO (BELOW) is being performed:
21 SI pump is running.
21 Charging pump is running and manually aligned to the RWST.
The minimum injection flow required per Figure ECA11-1 is ________.
To establish the minimum injection flow the SS will direct the _____________ be stopped.
- a. 200 gpm 21 SI pump
- b. 200 gpm 21 Charging pump
- c. 230 gpm 21 SI pump
- d. 230 gpm 21 Charging pump
SENIOR REACTOR OPERATOR Page 87 of 102 Question #
085 Given the following conditions:
Unit 1 is at 100% power.
Unit 1 experiences a SBLOCA.
Containment radiation level indicates 250 R/hr and rising slowly.
Containment pressure is 4 psig and stable.
To reduce containment radiation levels and permit longer Aux Building stay times the Unit 1 SS will direct placing the _______________________________ in service per __________________________________________________.
- a. Containment Spray system 1E-1, Response to Loss of Reactor or Secondary Coolant
- b. Containment Cleanup system 1FR-Z.3, Response to High Containment Radiation
- c. Containment Post-LOCA Ventilation system 1FR-Z.3, Response to High Containment Radiation
- d. Containment Dome Recirculation Fans 1E-1, Response to Loss of Reactor or Secondary Coolant
SENIOR REACTOR OPERATOR Page 88 of 102 Question #
086 Given the following conditions:
Unit 1 is shutdown.
RCS temperature is 175°F.
RCS pressure is 320 psig.
The running RHR pump locks out.
RCS temperature and pressure are increasing.
Both RCS loops are available for decay heat removal.
Overpressure protection for the RHR system is ________________________________
AND ___________________________ should be entered FIRST.
- b. adequate because the RHR suction MOVs automatically close on high pressure 1C15 AOP1, RHR Flow Restoration
- c. adequate because the RHR suction MOVs automatically close on high pressure 1E-4, Core Cooling following Loss of RHR Flow
- d. NOT adequate because the OPPS system is NOT in service 1C15 AOP1, RHR Flow Restoration
SENIOR REACTOR OPERATOR Page 89 of 102 Question #
087 Given the following conditions:
Unit 1 experienced a Large Break LOCA.
11 RHR pump is running in recirculation mode supplied by Sump B.
RWST Level is 7%.
Containment pressure is 10 PSIG and lowering slowly.
Containment level is 6.5 feet and stable.
Sump B level indicates 60% and slowly lowering.
1E-1, Loss of Reactor or Secondary Coolant, has been completed and long term plant status is being evaluated.
11 RHR pump amps have been lowering slowly since being started AND are oscillating.
The 11 RHR pump is cavitating due to ____________________________________.
The SS will ____________________________________.
- a. insufficient sump water level ensure all actions of 1ES-1.3, Transfer To Recirculation With One Safeguard Train Out of Service, have been performed
- b. boiling in the RHR heat exchangers complete the steps in 1ES-1.3, Transfer To Recirculation With One Safeguard Train Out of Service, to align more CC flow to 11 RHR HX
- c. Sump B strainers clogging with loose debris transition to 1ECA-1.3, Recirculation Sump Blockage, to secure pumps as needed
- d. flashing in the RHR pump suction lines from lowering Containment pressure transition to 1ECA-1.1, Loss of Emergency Coolant Recirculation, to reduce recirculation flow
SENIOR REACTOR OPERATOR Page 90 of 102 Question #
088 Given the following conditions:
Unit 1 is at 100% power.
A complete loss of CC flow to the letdown HX occurs.
No operator actions have been taken.
As a result, __________________________________ AND, to mitigate the failure, the SS is required to ____________________________________.
- a. VCT level will lower to a new stable value implement 1E-0, Reactor Trip or Safety Injection
- b. Pressurizer level will rise until the reactor trips implement 1C14 AOP1, Loss of Component Cooling
- c. Ion exchanger resins will release contaminants enter 1C12.1 AOP2, Loss of Charging Flow to the Regen HX
- d. VCT temperature will rise uncontrollably place Excess Letdown in service per 1C12.1, Letdown, Charging, and Seal Water Injection - Unit 1
SENIOR REACTOR OPERATOR Page 91 of 102 Question #
089 Given the following caution from various EOPs:
The basis for this Caution is that ____________________________________________ and the Manual Operator Action _____ maintain OPERABILITY of the safeguards equipment.
- a. SI logic requires manual operator action to remove the undervoltage signal to reset the circuitry does
- b. manual action must be taken to realign ALL safeguards equipment; otherwise the equipment would NOT restart does NOT
- c. SI must be reset to allow operating equipment to be shutdown, and automatic SI signals are NOT blocked after SI reset does
- d. safeguard equipment will NOT load onto emergency buses during normal sequencing after diesel generator startup does NOT
SENIOR REACTOR OPERATOR Page 92 of 102 Question #
090 Given the following conditions:
47019-0607, Unit 1 Containment condensate High Leak Rate, has been received.
The 11 Fan Coil Unit Weir Tank was found at 16 inches.
The 11 Fan Coil Unit Weir Tank was drained to 0 inches.
5 minutes later, the 11 Fan Coil Unit Weir Tank level returned to 16 inches and stabilized.
Figure 1 from C19.3, Leakage within Containment, is provided below.
There is a ___ gpm leak on the 11 Fan Coil Unit AND the SS is required to direct entry into __________________________________.
- a. 4 C35 AOP4, Cooling Water Leakage in Containment
- b. 4 C37.11 AOP1, Loss of Safeguards Chilled Water
- c. >10 C35 AOP4, Cooling Water Leakage in Containment
- d. >10 C37.11 AOP1, Loss of Safeguards Chilled Water
SENIOR REACTOR OPERATOR Page 93 of 102 Question #
091 Given the following conditions:
Step 13 of 1FR-S.1, Response to Nuclear Power Generation/ATWS, is in progress with the following conditions:
o The reactor trip breakers are being opened locally.
o Control rods are NOT Fully Inserted.
o The turbine is tripped.
o Emergency boration has been established.
o All power range channels read 5% reactor power.
o Both intermediate range (NFM) channels read 0.0 DPM.
o PZR level is off scale low.
o RCS pressure is 300 psig.
o Core exit thermocouples indicate 1350°F and lowering slowly.
1FR-S.1 page 7 and 8 are provided.
The SS will __________________________________________________________________
because ____________________________________________________________________.
- a. transition to 1FR-C.1, RESPONSE TO INADEQUATE CORE COOLING core exit thermocouples reading >1200°F indicate an extreme challenge to the fuel clad/matrix barrier and requires immediate operator action
- b. transition to 1SACRG-1, SEVERE ACCIDENT CONTROL ROOM GUIDELINE INITIAL
RESPONSE
attempts to restore core cooling have failed, core damage cannot be prevented and the operators should go to the SAMGs
- c. remain in 1FR-S.1, RESPONSE TO NUCLEAR POWER GENERATION/ATWS and continue to borate the RCS core exit thermocouples lowering indicates core cooling has been successful
- d. return to procedure and step in effect AND transition to 1FR-C.1, RESPONSE TO INADEQUATE CORE COOLING SI has not been successful in cooling the core, and the operators must perform alternative actions for establishing core cooling
SENIOR REACTOR OPERATOR Page 94 of 102 Question #
092 Given the following conditions:
Unit 1 has just entered Mode 1.
In-Service Purges 18 Inch Blind Flanges are discovered to be removed.
What are the implications, if any, of this discovery?
- a. None, as long as overall containment leakage was verified less than total allowed leakage.
- b. Unit 1 would enter LCO 3.0.3 for both trains of SBVS being INOPERABLE.
- c. None, T.S. credit the valves in the In-Service Purge line NOT the flanges.
- d. T.S. 3.6.3, Containment Isolation Valves, is not met.
SENIOR REACTOR OPERATOR Page 95 of 102 Question #
093 Given the following conditions:
Core reload refueling activities are in progress.
An irradiated fuel assembly is being lowered into the core with the HOIST JOG SWITCH.
The ENTERING CORE SLOW ZONE light has just extinguished.
The manipulator crane operator continues lowering the irradiated fuel assembly into the core, now using the HOIST CONTROL LEVER.
The hoist abruptly stops and the mast support tube is shaking noticeably.
The manipulator crane camera shows the fuel assembly is FULLY inserted.
The following indications are present:
o ENTERING CORE SLOW ZONE light is OFF.
o INTERMEDIATE CORE ZONE light is ON.
o BOTTOM CORE SLOW ZONE light is OFF.
o UNDERLOAD light is ON.
o SLACK CABLE light is ON.
o Gas bubbles are visible rising from the vicinity of the fuel assembly.
The ________________ control signal has failed.
The Containment SRO will implement ___________________ AND __________________.
- a. UNDERLOAD C1.6 AOP1, Containment Evacuation D5.2 AOP1, Damaged Fuel Assembly
- b. UNDERLOAD D5.2 AOP1, Damaged Fuel Assembly D5.2 AOP4, Spent Fuel Pool Area Evacuation-Refueling
- c. BOTTOM CORE SLOW ZONE C1.6 AOP1, Containment Evacuation D5.2 AOP1, Damaged Fuel Assembly
- d. BOTTOM CORE SLOW ZONE C1.6 AOP1, Containment Evacuation D5.2 AOP4, Spent Fuel Pool Area Evacuation-Refueling
SENIOR REACTOR OPERATOR Page 96 of 102 Question #
094 Given the following conditions:
Step 14 of 1FR-S.1, Response to Nuclear Power Generation/ATWS, is in progress with the following conditions:
o The reactor trip breakers are NOT OPEN.
o Control rods are NOT Fully Inserted.
o Normal and emergency boration CANNOT be established, including aligning the RWST to charging, due to flow path blockages.
o The turbine is tripped.
o All power range channels read 3% to 4% power.
o Both intermediate range (NFM) channels read +0.1 DPM o CETC indicate <700°F.
1FR-S.1 page 7 and 8 are provided.
The SS will __________________________________________________________________
because ____________________________________________________________________.
- a. exit 1FR-S.1 and return to the procedure and step in effect power is less than the design power level for auxiliary feedwater heat removal capability
- b. exit 1FR-S.1 and transition to 1FR-S.2, Response to Loss of Core Shutdown power channels are less than 5% with a startup rate greater than -0.2 DPM
- c. maintain stable RCS temperature and return to the procedure and step in effect stable temperatures preclude positive reactivity insertion by dilution
- d. allow the RCS to heat up and continue efforts to establish normal or emergency boration the RCS heat up will insert negative reactivity
SENIOR REACTOR OPERATOR Page 97 of 102 Question #
095 Given the following conditions:
Unit 1 and 2 are at 100% power.
An IMMINENT Airborne Threat has been verified with the NRC.
AB-8, Response to Security Threats, has been completed through Step 4, Initiate Plant Evacuation.
The Unit 1 SS, Unit 1 RO and Unit 2 RO are the ONLY personnel in the control room.
What are the minimum control room staffing requirements for the current plant conditions, and, in addition to continuing in AB-8, what action is required next?
Minimum Control Room Staffing Required Action
SENIOR REACTOR OPERATOR Page 98 of 102 Question #
096 Given the following note from T.S. 3.4.6:
What is the basis for this restriction?
- a. Prevent outsurge from emptying the pressurizer following an RCP start.
SENIOR REACTOR OPERATOR Page 99 of 102 Question #
097 Given the following conditions:
You are the Unit 1 SS.
A Unit 1 reactor startup is in progress following an inadvertent plant trip.
1C1.2, Unit 1 Startup Procedure, is in progress.
Control Bank A is being withdrawn.
ICCR is 0.28.
The last two 1/M plots indicate that criticality will be achieved on Control Bank "B" at approximately 100 steps.
The calculated ECC is CBD at 180 steps.
The SS is required to direct ____________________________________________________
per ________________________.
- a. a manual trip of the reactor 1E-0, Reactor Trip or Safety Injection
- b. manual insertion of ALL Control and Shutdown Bank rods 1C5, Control Rod and Rod Position Indication Systems
- c. manual insertion of the Control Bank rods AND verify minimum boron concentration C1B, Appendix - Reactor Startup
- d. suspending the startup to determine if criticality will be within 750 pcm of the ECC prior to proceeding C1A, Reactivity Calculations
SENIOR REACTOR OPERATOR Page 100 of 102 Question #
098 To perform fuel handling, _________________________ is required to be OPERABLE per tech specs to _________________________ in the event of a fuel handling accident.
- a. R-5, Spent Fuel Pool Area Monitor, ensure Aux Building Special Ventilation initiates,
- b. R-25, Spent Fuel Pool Air Monitor A, prevent offsite dose from exceeding the limits of 10CFR100,
- c. R-28, New Fuel Pit CRIT Area Rad Meter, ensure that a single train of SFPSVS is capable of filtering SFP enclosure air before it is vented to the AB ventilation system,
- d. R-31, Spent Fuel Pool Air Monitor B, prevent the CR operator dose from exceeding the limits of 10CFR50.67,
SENIOR REACTOR OPERATOR Page 101 of 102 Question #
099 Given the following conditions:
The Shift Manager became incapacitated and was transported offsite 30 minutes ago.
Unit 1 experienced a LOCA 15 Minutes ago.
The Plant Manager is the duty Emergency Director, but is not onsite yet.
A Non-Licensed Operator (NLO) has sustained life-threatening injuries in a high dose area while attempting to isolate the uncontrolled release.
Three rescue options are presented:
o Plan A would result in a dose of 37 Rem TEDE to the rescuer with very high probability of success.
o Plan B would result in a dose of 25 Rem TEDE to the rescuer with medium probability of success.
o Plan C would result in a dose of 4 Rem TEDE to the rescuer with low probability of success.
The rescuer is knowledgeable, fully briefed AND a volunteer.
The rescue plan is required to be authorized by the ________.
Based on expected dose, ______________ CAN be authorized.
- a. Unit 1 SS ONLY Plan C
- d. Unit 2 SS ANY of the plans
SENIOR REACTOR OPERATOR Page 102 of 102 Question #
100 Given the following conditions:
Unit 2 is at 100% power.
A Reactor trip and Safety Injection occur.
The Shift Supervisor notices the following:
o 22 SI Pump does NOT automatically start.
o 22 RHR Pump does NOT automatically start.
2E-0, Reactor Trip or Safety Injection, immediate actions are in progress.
The SS will direct the 22 SI pump and 22 RHR pump be started...
- a. immediately upon discovery.
- b. ONLY if Train A Safeguards equipment fails.
- c. after read through of 2E-0 Immediate Actions has been performed.
- d. ONLY if the Reactor Operator fails to start them as required by Immediate Actions.
SENIOR REACTOR OPERATOR ANSWER KEY Page 1 of 1 001
- b.
002
- c.
003
- c.
004
- a.
005
- c.
006
- a.
007
- c.
008
- d.
009
- a.
010
- a.
011
- c.
012
- c.
013
- d.
014
- a.
015
- a.
016
- a.
017
- d.
018
- a.
019
- a.
020
- b.
021
- d.
022
- c.
023
- c.
024
- b.
025
- b.
026
- c.
027
- a.
028
- c.
029
- a.
030
- d.
031
- b.
032
- c.
033
- d.
034
- c.
035
- d.
036
- c.
037
- a.
038
- b.
039
- a.
040
- d.
041
- a.
042
- d.
043
- a.
044
- b.
045
- c.
046
- c.
047
- a.
048
- b.
049
- a.
050
- d.
051
- a.
052
- d.
053
- c.
054 a. or c.
055
- b.
056
- b.
057
- a.
058
- a.
059
- c.
060
- a.
061
- d.
062
- a.
063
- c.
064
- b.
065
- d.
066
- a.
067
- c.
068
- b.
069
- d.
070
- a.
071
- a.
072
- d.
073
- d.
074
- b.
075
- b.
076
- b.
077
- a.
078
- c.
079
- b.
080
- a.
081
- c.
082
- a.
083
- c.
084
- b.
085
- b.
086
- b.
087
- c.
088
- d.
089
- d.
090
- c.
091
- c.
092
- d.
093
- c.
094
- d.
095
- c.
096
- b.
097
- c.
098
- b.
099
- d.
100 c.