Mid-Cycle Performance Review and Inspection Plan 2011 - Salem Nuclear Generating Station, Units 1 and 2
ML112411294
Person / Time
Site: Salem  
(DPR-070, DPR-075)
Issue date: 09/01/2011
From: Arthur Burritt
Reactor Projects Branch 3
To: Joyce T
Public Service Enterprise Group
BURRITT AL
References
IR-11-006
Download: ML112411294 (6)


Text

UNITED STATES NUCLEAR REGU LATORY COMMISSION REGION I 475 ALLENDALE ROAD KING OF PRUSSIA, PA 19406-1415 September [, 2011 Mr. Thomas P. Joyce President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P.O. Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

MID-CYCLE LETTER FOR SALEM IIIUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 (REPORT 05000272t2U10Ao and 05000311t2011006)

Dear Mr. Joyce:

On August 11,2011, the NRC completed its mid-cycle performance review of Salem Nuclear Generiting Station. The NRC reviewed the most rdcent quarterly performance indicators (Pls) in addition to inspection results and enforcement acrtions from July 1, 2010, through June 30, 2011. This letter informs you of the NRCs assessment of your facility during this period and its plans for future inspections at your faCility. This performance review and enclosed inspection plan do not include security information. A separate letter will include the NRCs assessment of your performance in the Security Cornerstone and its security-related inspection plan.

The NRC determined the performance at Salem Nuclear Generating Station during the most recent quarter was within the Licensee Response Column of the NRC's Reactor Oversight Process (ROP) Action Matrix because all inspection findings had very low (i.e., green) safety significance, and all Pls indicated that your performAnce was within the nominal, expected range (i.e., green). Therefore, the NRC plans to conduct ROP baseline inspections at your facility.

The enclosed inspection plan lists the inspections scheduled through December 31,2012.

Routine inspections performed by resident inspectors are not included in the inspection plan.

The inspections listed during the last nine months of the inspection plan are tentative and may be revised at the end-of-cycle performance review. The NRC provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. ln addition to the baseline inspections, we plan to conduct an inspection of your lSFSl. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes.

In the days following the Fukushima Daiichi nuclear accident in Japan, the Commission directed the staff io establish a senior-level agency task force to conduct a methodical and systematic review of the NRCs processes and regulations to determine whether the agency should make additional improvements to its regulatory system. The NRC has since completed Temporary lnstruction (Tl) 183, "Follow-up to Fukushima Daiichi Nuclear Station Fuel Damage Event j' and Tl-184,'Availability and Readiness Inspection of Severe Accident Management Guidelines (SAMGs)'at your facility. Results of these inspectiorrs can be found here:

http://www.nrc.qov/iapan/iapan-activities.html. Additionally, on May 1 1,2011, the agency issueO NnC guiletin 2Ot 1-01, "Mitigating Strategies;'1o confirm compliance with Order

T. Joyce EA-02-026, subsequently imposed license conditions, and 10 CFR 50.54(hhx2), and to determine the status of licensee mitigating strategies programs. On July 12,2011, the NRC's Task Force made its recommendations to the Comrnission in its report, 'Recommendations for Enhancing Reactor Safety in the 21't Century: The Near-Term Task Force Review of lnsights from the Fukushima DaiichiAccident." The NRC is currently reviewing the Task Force's recommendations to determine what additional actiQns may be warranted' In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.qov/readinq-rm/adams.html (the Public Electronic Reading Room).

Please contact me at 610-337-5069 with any questions you have regarding this letter.

Arthur L. Burritt, Chief Projects Branch 3 Division of Reactor Projects Docket Nos. 50-272, 50-31 1 License Nos. DPR-70, DPR-75

Enclosure:

lnspection Plan cc Mencl: Distribution via ListServ Sincerely,

.,.4 l

/ n 'rt7->

Ll/r'j n u

T. Joyce EA-02-026, subsequently imposed license conditions, and 10 CFR 50.54(hhx2), and to determine the status of licensee mitigating strategies programs. On July 12,2011, the NRCs Task Force made its recommendations to the Commission in its report, "Recommendations for Enhancing Reactor Safety in the 21't Century: The Near-Term Task Force Review of lnsights from the Fukushima DaiichiAccidentl' The NRC is currently reviewing the Task Forces recommendations to determine what additional actions may be warranted.

ln accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Pubticly Available Reiords (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.qov/readinq-rm/adams.html (the Public Electronic Reading Room).

please contact me at 610-337-5069 with any questions you have regarding this letter.

Sincerely,

/RA/

Arthur L. Burritt, Chief Projects Branch 3 Division of Reactor Projects Docket Nos. 50-272, 50-31 1 License Nos. DPR-70, DPR-75

Enclosure:

Inspection Plan cc dencl: Distribution via ListServ 2

Distribution: See attached page SUNSI REVIEW COMPLETE: ALB (Reviewer's Initials)

DOCUM ENT NAME: S:\\ROP-1 2 M I D-CYC LE REVI E\\AABRANCH 3\\LEfi ERS(ATTACHMENTI )\\

SALEM MID-CYCLE LETTER2OI 1.DOCX After declaring this document "An Official Agency Record" it wilt be released to the Public.

ML112411294 of this document, indicate in box:"C" = Copy w/o attachment/enclosure, E" = Copy w/ attachmenUenclosure"N'=No copy OFFICIAL RECORD COPY

T. Joyce Distribution Mencl:

W. Dean, RA (RIORAMAIL Resource)

D. Lew, DRA (RIORAMAlL Resource)

D. Roberts, DRP (RIDRPMAlL Resource)

J. Clifford, DRP (RIDRPMAlL Resource)

C. Miller, DRS (RlDRSMail Resource)

P. Wilson, DRS (Rl DRSMail Resource)

A. Burritt, DRP L. Cline, DRP A. Turilin, DRP C. Douglas, DRP D. Schroeder, DRP, SRI P. McKenna, DRP, Rl K. McKenzie, DRP, OA J. McHale, Rl OEDO DRS Branch Chiefs (6)

N. McNamara, Rl, SLO D. Tiffi, RI, SLO D. Screnci, Rl, PAO N. Sheehan, Rl, PAO R. Barkley, Rl, ORA RidsNrrPMSalem Resource RidsNrrDorllpl 1 -2 Resource ROPreports Resource RidsNrrDirslpab Resource ROPassessment Resource 3

Page I of 2 08t29t2011 Report 22 08:59:34 Salem Inspection I Activity Plan 07t0112011 - 12t31t2012 Unit Number 1

t

't,2 1,2

't,2 1,2 1,2 1,2 1,2 1

1 1

,l 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 Planned Dates Start End O912EXM. OPERATOR LICENSING INITIAL EXAMS 08115t201',t 08t19t2011 U01830 FY11-SALEM, lNlTlAL OL EXAM 09/19/201 1 09t23t2011 U01 830 FY1 1-SALEM, lNlTlAL OL EXAM 71152

- Pl&R 06127120'11 07101120'11 lP 711528 Problem ldentification and Resolution 0711812011 07l22l2Af P 711528 Problem ldentification and Resolution 7111118.SALEM REQUALINSPw/ P/F RESULTS 0812212011 0812612011 lP 71111'118 Licensed Operator Requalification Program rsFsr

- rsFsilNsPEcTroN 0711512011 081'l9l201'l lP 60855.1 Operation of an Independent Spent Fuel Storage Installation at Operating Plants 71124

. REMP 07125t2011 0712912011 tP 71124.07 71124

- HP Radiological Environmental Monitoring Program 1OE1l2O11 1110412011 lP 25151179 Verification of Licensee Responses to NRC Requirement for Inventories of Materials Tracked in NSTS 1013112011 11104120'11 lP 60855.1 Operation of an Independent Spent Fuel Storage Installation at Operating Plants 1013112011 11lO4l2O'11 lP 71124.01 Radiological Hazard Assessment and Exposure Controls 1013112011 1'll04l2011 lP 71124.02 Occupational AtiRA Planning and Controls fiR1t2011 1110412011 lP 71124.Os Radiation Monitoring Inshumentation 7111108P. U1 INSERVICE INSPECTION 1'110712011 1111812011 lP 711'l1OBP Inservice Inspection Activities - PWR 71124

. RADWASTE 1210512011 120912011 lP 71'l24.Og Radioactive Solid Waste Processing and Radioactive Material Handling, Storage, and Transportation TRI FIRE. TRIENNIAL FIRE PROTECTION INSPECTION 0112312012 0'112712012 lP 71 11105T Fire Protection [Triennial]

02106,12012 O2l1Ol2O12 lP 7111105T Fire Protection flriennial]

71124.06. PUB RAD SAFETY. RETS 0113012012 02lO3l2O'12 lP 71124.05 Radiation Monitoring Instrumentation 0113012012 A2lO3l2O12 lP 71 124.06 Radioactive Gaseous and Liquid Effluent Treatment 71124

- OCC RDASAFEW 0311212012 0311612012 lP 7'1124.01 Radiological Hazard Assessment and Exposure Controls 03112120'12 0311612012 lP 71124.02 Occupational ALAM Planning and Controls 0311212012 0311612012 lP 71124.05 Radiation Monitoring lnstrumentation EP EX

- EP EXERCISE EVALUATION 0512112012 0512512012 lP 7'111401 Exercise Evaluation No. of Staff on Site fhis report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspeclion procedures,

Page 2 of 2 0812912011 08:59:34 Report 22 Salem Inspection / Activity Plan 0710112011 - 12t31t2012 No. of

't,2 1,2 1,2 1,2 1,2 1

'l 1,2 2

2 1,2 1,2 2

05t21t20't2 06t1112012 06.t11t2012 06t11t2012 06t11t2012 10t22t20't2 11119t2012 10t22t2012 10t22t2012 10t2212012

'tot22t20't2 10t22t20't2 1022tnt2 05125t2012 06t1512012 o6t15t2012 46n5t2012 06t15t2012 10n6t2012 11t23t2012 10t26t2012 10t26t2012 10t26t2012 10t26t2012 10t26t2012

't'vg2t2a12 EP EX tP 71114M 71124 tP 71124.02 tP 7'.t't24.03 tP 71124.04 lP 71124.05 u01859 u01 859 71'l.24 tP 60855.1 tP 71124.01

- EP EXERCISE EVALUATION Emergency Action Level and Emergency Plan Changes

- OCC RAD SAFETY Occupational ALAM Planning and Controls In-Plant Airborne Radioactivity Control and Mitigation Occupational Dose Assessment Radiation Monitoring Instrumentation 11/19EXM. SALEM INITIAL EXAM FYl3.SALEM INITIAL OPEMTOR LICENSING EXAM FY13-SALEM INITIAL OPEMTOR LICENSING EXAM

. RAD SAFETY tP 71124.02 tP 71151-OR01 tP 71151-PR01 71I1108P. U2INSERVICE INSPECTION lP 7111108P Inservlce lnspection Activities - PWR Operation of an Independent Spent Fuel Storage Installation at Operating Plants Radiological Hazard Assessment and Exposure Controls Occupational ALARA Planning and Controls Occupational Exposure Control Effectiveness RETS/ODCM Radiological Effluent