Text
1717 Wakonade Drive Welch, MN 55089
February 29, 2024 L-PI-24-004 10 CFR 72.44(d)(3)
ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555- 0001
Prairie Island Nuclear Generating Plant, Units 1 and 2 Docket Nos. 50- 282 and 50- 306 Renewed Facility Operating License Nos. DPR- 42 and DPR-60
Prairie Island Independent Spent Fuel Storage Installation Docket No. 72- 10 Materials License No. SNM-2506
Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January through December 2023
Pursuant to the requirements of 10 CFR 72.44(d)(3) and the Prairie Island Nuclear Generating Plant ISFSI Technical Specifications, Section 5.3, Northern States Power Company, a Minnesota corporation, doing business as Xcel Energy (hereafter NSPM), submits the enclosed ISFSI Annual Effluent Report for the period of January through December 2023 .
Summary of Commitments
This letter makes no new commitments and no revisions to existing commitments.
Timothy P. Borgen Plant Manager, Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota
Enclosure
cc: Administrator, Region III, USNRC Project Manager, Prairie Island, USNRC Resident Inspector, Prairie Island, USNRC State of Minnesota, Department of Commerce ENCLOSURE
PRAIRIE ISLAND NUCLEAR GENERATING PLANT INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
ANNUAL EFFLUENT REPORT, JANUARY 2023 THROUGH DECEMBER 2023
Independent Spent Fuel Storage Installation 50 Total Casks
During the 2023 calendar year, there were zero (0) additional casks loaded and placed in the Prairie Island ISFSI. At the end of the 2023 calendar year, there remains a total of fifty (50) casks loaded in the Prairie Island ISFSI.
Airborne Effluent Releases from the ISFSI 0.00E+00 Ci
There was no airborne effluent release from the Prairie Island ISFSI during the calendar year 2023.
Liquid Effluent Releases from the ISFSI 0.00E+00 Ci
There was no liquid effluent release from the Prairie Island ISFSI during the calendar year 2023.
Dose to Individuals Due to ISFSI Effluent Releases 0.00E+00 mrem
Page 1 of 1