MONTHYEARML18011A0852018-01-30030 January 2018 Letter to Senator Cory Booker from Chairman Svinicki Regarding Constituent Questions Regarding the Decommissioning of Oyster Creek Nuclear Generating Station in Lacey Township, New Jersey ML17356A0342017-12-21021 December 2017 12-21-17 Acknowledgement Letter to Senator Cory Booker - Oyster Creek ML13043A9402013-02-27027 February 2013 G20130075/LTR-13-0071 - Letter to Sen. F. Lautenberg from Chairman Macfarlane Responds to Concerns Regarding the Safety of the Oyster Creek Nuclear Generating Station Following Hurricane Sandy ML13035A2612013-02-22022 February 2013 Letter to Sen. R. Menendez from Chairman Allison Macfarlane Oyster Creek Generating Station and Impact of Hurricane Sandy on the Plant ML13035A2642013-02-22022 February 2013 Ltr. to Sen. R. Menendez from Chairman Allison Macfarlane - Oyster Creek Generating Station - Enclosure ML13029A6122013-01-25025 January 2013 G20130075/LTR-13-0071 - Ltr. Senator Frank R. Lautenberg Update on Actions Being Taken by the Nuclear Regulatory Commission to Address Safety Concerns That Have Been Reported at the Oyster Creek Nuclear Generating Station Following Supersto ML13017A0402013-01-14014 January 2013 G20130037/LTR-13-0043 - Ltr. Senator Robert Menendez Provides Questions Concerning the Oyster Creek Nuclear Plant ML12187A2342012-06-0606 June 2012 G20120474/LTR-12-0306/EDATS: SECY-2012-0341 - Sen. Robert Menendez Ltr. Safety of Our Aging Nuclear Power Plants with Focus on Oyster Creek ML13218A0992012-03-28028 March 2012 03-28-12 LTR-12-0125 Letter from Honorable Robert Menendez and Honorable Frank R. Lautenberg on Meeting Held on March 28, 2012 to Discuss the Annual Safety Assessment of the Oyster Creek Nuclear Power Plant ML11264A0902011-09-13013 September 2011 Comment (8) of John Runyan, on Behalf of Self, on Consideration of Rulemaking to Address Prompt Remediation of Residual Radioactivity During Operations CY-92-223, G20110523/LTR-11-0411/EDATS: SECY-2011-0411 - Ltr. from Rep. E.J. Markey to Chairman Jaczko NRC Safety Requirements for Reactors Granted Construction Permits Prior to 19712011-07-14014 July 2011 G20110523/LTR-11-0411/EDATS: SECY-2011-0411 - Ltr. from Rep. E.J. Markey to Chairman Jaczko NRC Safety Requirements for Reactors Granted Construction Permits Prior to 1971 ML11188A0052011-06-23023 June 2011 G20110496/LTR-11-0386/EDATS: SECY-2011-0390 - Rep. Jon Runyan Ltr. June 2011 Gao Report Entitled, Nuclear Regulatory Commission, Oversight of Underground Piping Systems Commensurate with Risk, But Proactive Measures Could Help Address Futur ML1014107522010-05-20020 May 2010 G20100323/LTR-10-0235/EDATS: SECY-2010-0287 - Ltr Fm Senator Robert Menendez Oyster Creek - Tritium Leak ML0916001912009-11-13013 November 2009 G20090312/EDATS: OEDO-2009-0345 - Robert Menendez Ltr. Engaging Sandia National Laboratory to Review the Analyses of the Integrity of the Oyster Creek Drywell Liner ML0915201382009-10-27027 October 2009 G20090291/LTR-09-0211/EDATS: SECY-2009-0249 - Ltr to Representative Christopher Smith Fm Chairman Gregory Jaczko Relicensing Process for Oyster Creek ML0915604112009-07-27027 July 2009 G20090306/LTR-09-02291/EDATS: SECY-2009-0229 - Ltr to Congressman John Adler from Chairman Jaczko Oyster Creek Relicensing Process ML0914805812009-05-27027 May 2009 G20090306/LTR-09-0229/EDATS: SECY-2009-0256 - Rep. John Ader, Ltr Oyster Creek Nuclear Power Plant - Relicensing Process ML0915301592009-05-21021 May 2009 G20090312/EDATS: OEDO-2009-0345 - Robert Menendez Ltr. Engaging Sandia National Laboratory to Review the Analyses of the Integrity of the Oyster Creek Drywell Liner ML0914000662009-05-18018 May 2009 G20090291/LTR-09-0211/EDATS: SECY-2009-0249 - Representative Christopher Smith Relicensing Process for Oyster Creek ML0932006292009-05-0606 May 2009 Letter from Senator Connors and Assemblyman Rumpf and Pelt, to Commissioner Mauriello, Oyster Creek Generating Station - Tritium - Additional Request Regarding Briefing ML0903603812009-02-0303 February 2009 Letter to Chairman Klein from Christopher H. Smith, U.S. Congress, Request the NRC Postpone the Affirmation Session and Any Decision on Extending the Operating License Be Deferred Etc ML0903604032009-02-0303 February 2009 Letter to Chariman Klein from John Adler, U.S. Congress - Request the NRC Postpone the Scheduled Affirmation Until Recommendations by Two NRC Advisory Boards Are Further Reviewed ML0906305672009-02-0303 February 2009 G20090108/LTR-09-0037/EDATS: SECY-2009-0084 - Ltr. from Rep. John Adler, Frank Lobbiondo, and Rush Holt Postponement of Commission Decision on Relicensing of the Oyster Creek ML0901406652009-01-29029 January 2009 G20090009/LTR-08-0614/EDATS: SECY-2009-0008 Congressman Christopher Smith Ltr. Oyster Creek Refueling and Maintenance Shutdown ML0900703332008-12-0404 December 2008 G20090009/LTR-08-0614/EDATS: SECY-2009-0008 - Ltr. Representative Christopher H. Smith Oyster Creek Refueling and Maintenance Shutdown RA-08-114, NRC Response to J. Tauro - Grandmothers, Mothers, and More for Energy Safety (Grammes) Regarding Oyster Creek2008-06-23023 June 2008 NRC Response to J. Tauro - Grandmothers, Mothers, and More for Energy Safety (Grammes) Regarding Oyster Creek ML0817504282008-06-23023 June 2008 NRC Response to J. Tauro - Grandmothers, Mothers, and More for Energy Safety (Grammes) Regarding Oyster Creek ML0812600052008-05-16016 May 2008 G20080283/EDATS: SECY-2008-0245/LTR-08-0223 - Rep. Chris Smith & Rep. Jim Saxton Ltr from R. W. Borchardt Oyster Creek License Renewal Application ML0811603062008-04-25025 April 2008 Letter from Annette L. Vietti-Cook to the Honorable Jim Saxton and the Honorable Chris Smith in Response to Their 04/17/08 Letter ML0811604202008-04-17017 April 2008 G20080283/EDATS: SECY-2008-0245/LTR-08-0223 - Ltr. Rep. Chris Smith & Rep. Jim Saxton Oyster Creek License Renewal Application ML0704400392007-03-16016 March 2007 G20070092/LTR-07-0087 - Rep. Jim Saxton Ltr Re Oyster Creek - Floor Structure of the Spent Fuel Pool ML0703804812007-01-30030 January 2007 G20070092/LTR-07-0087 - Rep. Jim Saxton Ltr Re Oyster Creek - Floor Structure of the Spent Fuel Pool ML0702505002007-01-18018 January 2007 LTR-07-0041 - Rep. Jim Saxton Ltr. Re Urges the NRC to Grant New Jersey'S Request for a Hearing Concerning the Oyster Creek Generating Station ML0627202102006-10-30030 October 2006 G20060809/LTR-06-0482 - Rep. Jim Saxton, Rep. Christopher H. Smith, Rep. Robert E. Andrews, Rep. Rush Holt, Rep. Frank Pallone, Jr., and Rep. Bill Pascrell, Jr. Ltr Oyster Creek Nuclear Generating Facility ML0628903322006-10-10010 October 2006 Letters from Annette L. Vietti-Cook to Six Members of Congress Responding to Their 09/26/06 Letter (Also Enclosed) Re Effects of Water Leakage and Corrosiion on the Structural Integrity of the Containment Wall of the Oyster Creek Reactor ML0627200182006-09-26026 September 2006 G20060809/LTR-06-0482 - Rep. Christopher H. Smith, Rep. Jim Saxton, Rep. Robert E. Andrews, Rep. Rush Holt, Rep. Frank Pallone, Jr., and Rep. Bill Pascrell, Jr. Ltr Oyster Creek Nuclear Generating Facility ML0623000762006-08-25025 August 2006 G20060714/LTR-06-401 - Rep. Jim Saxton Ltr. Re Comments Regarding the Draft Environmental Impact Statement (Deis) Issued as Part of the Operating License Renewal Process for Oyster Creek Generating Facility ML0624800412006-08-0909 August 2006 2006/08/09-Comment (2) of Jim Saxton Opposing Draft Environmental Impact Statement (EIS) Issued as Part of the Operating License Renewal Process for the Oyster Creek Nuclear Generating Facility in Forked River, New Jersey ML0624204412006-08-0909 August 2006 Letter from Representative Saxton Regarding the Draft Environmental Impact Statement for License Renewal of Oyster Creek Nuclear Generating Station ML0622800402006-08-0909 August 2006 G20060714/LTR-06-0401 - Ltr. Rep. Jim Saxton Comment on the Draft Environmental Impact Statement (Deis) Issued as Part of the Operating License Renewal Process for the Oyster Creek Generating Facility ML0614202402006-06-0505 June 2006 2006/06/05-G20060495 - Rep. Robert Andrews Ltr. EDO Re License Renewal Application of Oyster Creek ML0613603432006-05-0505 May 2006 G20060495 - Rep. Robert Andrews Ltr. Re License Renewal Application of Oyster Creek ML0609406252006-03-24024 March 2006 2006/03/24-Letter from Annette L. Vietti-Cook to Congressman Smith Responding to His 02/16/06 Letter Requesting That a Hearing Be Held on the License Renewal Application for Oyster Creek ML0604507462006-03-16016 March 2006 G20060110/LTR-06-0055 - Representative Jim Saxton Ltr. Re Oyster Creek Nuclear Generating Station - Ultrasonic Testing ML0606003172006-02-27027 February 2006 Letter from Annette L. Vietti-Cook to Congressman Andrews Responding to His 02/06/06 Letter (Also Enclosed) Regarding the Oyster Creek Proceeding ML0604702492006-02-14014 February 2006 Letter from Annette L. Vietti-Cook to Congressman Saxton Responding to His 01/27/06 Letter (Also Enclosed) Regarding the Oyster Creek Proceeding ML0603401252006-01-27027 January 2006 G20060110/LTR-06-0055 - Representative Jim Saxton Ltr. Re Oyster Creek Nuclear Generating Station - Ultrasonic Testing ML0522800492005-09-14014 September 2005 G20050560/LTR-05-0406 - Rep. Jim Saxton Ltr Comprehensive Review of Exelon Corporation Renewal Application to Extend the Operating License of Oyster Creek Nuclear Generating Station ML0522201772005-08-0303 August 2005 G20050560/LTR-05-0406 - Rep. Jim Saxton Ltr Comprehensive Review of Exelon Corporation Renewal Application to Extend the Operating License of Oyster Creek Nuclear Generating Station ML0515402332005-05-23023 May 2005 G20050400/LTR-05-0284 - Rep. Jim Saxton Ltr Site-Specific Vulnerability Analysis on the Spent Fuel Pool for Oyster Creek 2018-01-30
[Table view] Category:Letter
MONTHYEARML23342A1162024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 IR 05000219/20230022023-11-0909 November 2023 EA-23-076 Oyster Creek Nuclear Generating Station - Notice of Violation and Proposed Imposition of Civil Penalty - $43,750 - NRC Inspection Report No. 05000219/2023002 ML23286A1552023-10-13013 October 2023 Defueled Safety Analysis Report (DSAR) ML23249A1212023-09-0606 September 2023 NRC Inspection Report 05000219/2023002, Apparent Violation (EA-23-076) ML23242A1162023-08-30030 August 2023 Biennial 10 CFR 50.59 and 10 CFR 72.48 Change Summary Report January 1, 2021 Through December 31, 2022 ML23214A2472023-08-22022 August 2023 NRC Inspection Report 05000219/2023002 IR 05000219/20230012023-05-31031 May 2023 NRC Inspection Report No. 05000219/2023001 IR 07200015/20234012023-05-16016 May 2023 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2023401 ML23114A0912023-04-24024 April 2023 Annual Radioactive Effluent Release Report for 2022 ML23114A0872023-04-24024 April 2023 Annual Radioactive Environmental Operating Report for 2022 L-23-004, HDI Annual Occupational Radiation Exposure Data Reports - 20222023-04-24024 April 2023 HDI Annual Occupational Radiation Exposure Data Reports - 2022 L-23-003, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-31031 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations ML23088A0382023-03-29029 March 2023 Stations 1, 2, & 3, Palisades Nuclear Plant, and Big Rock Point - Nuclear Onsite Property Damage Insurance ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities IR 05000219/20220022023-02-0909 February 2023 NRC Inspection Report No. 05000219/2022002 ML23031A3012023-02-0808 February 2023 Discontinuation of Radiological Effluent Monitoring Location in the Sewerage System ML23033A5052023-02-0202 February 2023 First Use Notification of NRC Approved Cask RT-100 ML23025A0112023-01-24024 January 2023 LLRW Late Shipment Investigation Report Per 10 CFR 20, Appendix G ML22347A2732022-12-21021 December 2022 Independent Spent Fuel Storage Installation Security Inspection Plan Dated December 21, 2022 ML22297A1432022-12-15015 December 2022 Part 20 App G Exemption Letter L-22-042, Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.152022-12-14014 December 2022 Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.15 IR 07200015/20224012022-12-0606 December 2022 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2022401 (Letter & Enclosure 1) ML22280A0762022-11-0202 November 2022 Us NRC Analysis of Holtec Decommissioning Internationals Funding Status Report for Oyster Creek, Indian Point and Pilgrim Nuclear Power Station ML22276A1762022-10-24024 October 2022 Decommissioning International Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22286A1402022-10-13013 October 2022 NRC Confirmatory Order EA-21-041 IR 05000219/20220012022-08-11011 August 2022 NRC Inspection Report 05000219/2022001 ML22215A1772022-08-0303 August 2022 Decommissioning International (HDI) Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22214A1732022-08-0202 August 2022 Request for Exemption from 10 CFR 20, Appendix G, Section Iii.E ML22207B8382022-07-26026 July 2022 NRC Confirmatory Order EA-21-041 ML22130A6882022-05-10010 May 2022 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-22-026, Occupational Radiation Exposure Data Report - 20212022-04-29029 April 2022 Occupational Radiation Exposure Data Report - 2021 ML22118A6122022-04-28028 April 2022 Annual Radioactive Environmental Operating Report for 2021 ML22118A5822022-04-28028 April 2022 Annual Radioactive Effluent Release Report for 2021 ML22091A1062022-04-0101 April 2022 Nuclear Onsite Property Damage Insurance (10 CFR 50.54(w)(3)) L-22-022, and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec.2022-03-25025 March 2022 and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec. ML22069A3762022-03-10010 March 2022 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G ML22032A0582022-03-0808 March 2022 EA-21-139; EA-150: Oyster Creek Nuclear Generating Station - NRC Investigation Report Nos.. 1-2021-002 & 1-2021-014 ML22060A2202022-03-0202 March 2022 NRC Office of Investigations Case No. 1-2021-009 ML22049B2452022-02-19019 February 2022 Late Low Level Radwaste Shipment Report Pursuant to 10 CFR 20 Appendix G IR 05000219/20214022022-01-26026 January 2022 EA-21-041: Confirmatory Order Related to Oyster Greek Nuclear Generating Station - NRC Investigation Report I-2020-007; NRC Inspection Report Nos. 05000219/2021402 & 07200015/2021401 ML22025A3422022-01-25025 January 2022 and Big Rock Point - Changes to Site Organization ML22025A2182022-01-25025 January 2022 Late LLRW Shipments Investigation Report Pursuant to 10 CFR 20, Appendix G ML22021B5512022-01-21021 January 2022 Compensatory Measures Not Implemented Per Site'S Physical Security Plan Due to Multiplexer (Mux) Power Supply Failure L-21-134, and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations2021-12-17017 December 2021 and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations ML21349A5192021-12-15015 December 2021 Commitment Change Summary Report ML21285A1912021-11-30030 November 2021 Nrc'S Analysis of Holtec Decommissioning International'S Decommissioning Funding Status Report for Oyster Creek Nuclear Generating Station and Pilgrim Nuclear Power Station, Docket Nos 50-219 and 50-293 IR 05000219/20210032021-11-16016 November 2021 NRC Inspection Report No. 05000219/2021003 L-21-118, Changes to Signature Authority & Addressee for Holtec Decommissioning International, LLC Correspondence Re to Oyster Creek Nuclear Generating Station, Pilgrim Nuclear Power Station, Indian Point Nuclear Generating Units 1, 2, 3, & Palisades2021-11-0909 November 2021 Changes to Signature Authority & Addressee for Holtec Decommissioning International, LLC Correspondence Re to Oyster Creek Nuclear Generating Station, Pilgrim Nuclear Power Station, Indian Point Nuclear Generating Units 1, 2, 3, & Palisades IR 05000219/20214042021-08-26026 August 2021 NRC Independent Spent Fuel Storage Security Inspection Report No. 07200015/2021402 and Security Decommissioning Inspection Report 05000219/2021404 - (Public) 2024-01-09
[Table view] |
Text
July 27, 2009 The Honorable John H. Adler United States House of Representatives Washington, D.C. 20515
Dear Congressman Adler:
On behalf of the U.S. Nuclear Regulatory Commission (NRC), I am responding to your letter of May 27, 2009, in which you expressed concern about a leak in buried piping at the Oyster Creek Generating Station (Oyster Creek).
The NRC has reviewed the Oyster Creek issue noted in your letter and has closely monitored the licensees corrective action. Although not desirable, the leakage identified at Oyster Creek did not impact the health and safety of the public. Nonetheless, the NRC believes that leakage in an underground pipe that has the potential to impact the environment due to groundwater contamination is an issue that should be addressed seriously. The NRC will continue to examine the specific details associated with the Oyster Creek condensate system leak. In addition, the staff will review the regulatory requirements, industry codes and standards for inspection of buried piping to ensure that the test requirements meet the expectations for maintenance of safety systems. In the enclosure to this letter, I have provided detailed responses to your questions which were prepared by the NRC staff.
The NRC reviews and assesses nuclear plant design, licensing requirements, and performance to ensure that reactors are operating safely and in accordance with applicable regulations. The NRC regulations require periodic testing of safety-related buried piping, and require that licensees take corrective action for degraded conditions. In the case of significant degraded conditions, NRC regulations also require that the licensee take corrective action to preclude the reoccurrence of the condition. NRC inspectors routinely inspect the licensees programs including licensees inservice inspection programs as part of the baseline inspections in the Reactor Oversight Process and verify that licensees have taken appropriate corrective actions. Issues identified by NRC inspectors are assessed for safety significance and documented in publicly available inspection reports. The NRC continues to closely monitor any degradation in safety-related systems at nuclear power reactors, and will take appropriate regulatory or enforcement action if conditions warrant.
The NRC continuously reviews new operating experience with buried piping for potential generic implications to the industry. Based on further or new information that becomes available through the agencys continued inspection and oversight of the issue, the NRC will consider generic aspects of the issue to determine if generic communications on the subject are warranted. The agency will also continue to review our inspection requirements and oversight processes to ensure our inspection approach appropriately considers the buried piping issues commensurate with their safety significance.
The NRC staff is available to provide a briefing for your staff if you desire. If you have additional questions on this matter, please contact me.
Sincerely,
/RA/
Gregory B. Jaczko
Enclosure:
As stated
NRC Response to May 27, 2009, Information Request Question 1:
Does the Commission require licensees to conduct inspections of their buried pipes? If not, why not? If so, how often are licensees required to inspect their buried pipes?
Answer 1:
The Nuclear Regulatory Commission (NRC) requires licensees to conduct inspections and tests that verify the integrity of buried piping. The requirements for these inspections vary depending upon the safety significance of the piping.
In the case of safety-related piping, licensees are required to comply with Title 10 of the Code of Federal Regulations (10 CFR), Section 50.55a, Codes and Standards, which requires that licensees implement an inservice inspection program that complies with the standards of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code).
The ASME Code provides requirements for the examination and testing associated with safety-related buried piping. Licensees, such as Exelon, which operates the Oyster Creek Nuclear Generating Station (Oyster Creek), are required to implement applicable ASME Code requirements through site-specific processes and procedures that comprise their inservice inspection and inservice testing programs.
Licensees are also required to comply with 10 CFR 50.65, Requirements for monitoring the effectiveness of maintenance at nuclear power plants, which requires monitoring the performance or condition of structures, systems, and components, against licensee-established goals, in a manner sufficient to provide reasonable assurance that these structures, systems, and components are capable of fulfilling their intended functions. The scope of the monitoring program required by 10 CFR 50.65 includes safety-related and non-safety-related components that are relied upon to mitigate adverse conditions and accidents or whose failure could prevent safety-related components from fulfilling their safety-related function.
Applicants for license renewal must also meet the safety requirements of 10 CFR Part 54, Requirements for Renewal of Operating Licenses for Nuclear Power Plants. For license renewal, aging management of buried piping relies on opportunistic (e.g., when the piping is excavated for another reason) or focused inspections of buried piping systems. Prior to entering the period of extended operation, the applicant is required to verify that there has been at least one opportunistic or focused inspection performed within the past 10 years. Upon entering the period of extended operation, the applicant is required to perform another focused inspection within 10 years, unless an opportunistic inspection has otherwise occurred within this 10-year period. These inspections should be performed in areas with the highest likelihood of corrosion problems.
Exelon has an underground piping aging management program that directs inspection activities at Oyster Creek for safety and non-safety-related buried piping. Through this program, the licensee determines the frequency of piping inspections based upon the susceptibility of the Enclosure
piping to degradation and the consequence of its failure. The licensees corrective action program identifies, evaluates, and implements corrective actions for adverse conditions commensurate with the safety significance of the condition. The NRC staff has verified that Exelon initiated several corrective action items to address the tritium leakage onsite and the subsequent buried piping problems noted in April 2009, following excavation of the piping.
For Oyster Creek, the Condensate System, which preliminarily has been determined to be the source of the tritium leak, is a non-safety-related system. According to Exelons buried piping aging management program, this system is subjected to flow surveillance testing on a quarterly basis, testing which can reveal significant piping leaks. Exterior inspections of the piping are conducted on an opportunistic basis when the buried sections of pipe are exposed. The NRC will continue to observe, assess, and document Exelons actions taken to address this issue and precluding future problems. Exelon has additional programs in place that monitor groundwater conditions onsite and test potential effluents before release. These environmental programs provide an additional barrier for detection of leakage from buried pipes.
Question 2:
How much of each pipe is the licensee required to inspect - a segment or the entire pipe?
Answer 2:
The licensee is not required to inspect the entire length of all buried pipes. The inspection of safety-related piping is governed by 10 CFR 50.55a and the ASME Code. Exelons buried piping aging management program also does not require that a specific length of piping be inspected. Piping integrity is verified by a number of different methods, such as hydrostatic (e.g., pressure-drop) or flow testing, which check system integrity as a whole. Inspections of opportunity conducted on exterior portions of excavated piping verify the condition of segments of a pipe and provide an indication of the condition of the remainder of the pipe.
Exelons buried piping inspection program, corrective action program, and 10 CFR 50.65 program focus Exelons inspection, testing, and maintenance efforts on areas of piping that are of higher safety significance and are more susceptible to degradation. In focusing its efforts, the licensee is able to use operating experience from both Oyster Creek and other industrial plants with similar conditions. The NRC regulations and Exelons procedures require any degradation to be promptly identified and corrected.
Question 3:
Is the inspection conducted on all of the licensees buried pipes or just a sampling? If it is a sampling, how is this sampling determined and by whom is this sampling determined?
Answer 3:
The licensee is not required to inspect the entire length of all buried pipes. The inspection of safety-related piping is governed by 10 CFR 50.55a and the ASME Code. The licensees buried
piping aging management program governs the inspection of non-safety-related piping and augments the inspection of safety-related piping. The sampling size and frequency of inspections performed are determined by the licensee considering both the susceptibility of the piping to degradation and the consequence of its failure.
Question 4:
Does the Commission require an independent party to conduct buried pipe inspections in addition to the licensee? If not, why not?
Answer 4:
The NRC performs inspections that independently verify licensee compliance with ASME Code requirements and, where applicable, adherence to its buried piping aging management program. The NRC conducts oversight of the licensees inspections to verify their adequacy.
Licensees are not required to have a third-party perform buried piping inspections.
Question 5:
Regarding Oyster Creek specifically, when was the licensee most recently required to inspect their buried pipe system?
Answer 5:
There are multiple systems that contain buried piping running between unconnected buildings.
As described in the response to Question 1, different systems are inspected at different frequencies. Buried pipe inspection activities are conducted at frequencies that are commensurate with the susceptibility to degradation and the consequence relative to radiological or operational safety.
The most recent planned inspection of buried piping was conducted by Exelon in 2008 in accordance with license renewal commitments. As noted in the publicly available NRC Inspection Report, two carbon steel buried pipes, one aluminum buried pipe, and one cast iron buried pipe were excavated and visually inspected with no identified deficiencies.
In addition to the aforementioned buried piping inspections and replacements in April 2009, Exelon accomplished the following at Oyster Creek:
- During the period between 2004 and 2008, 100% of safety-related underground Emergency Service Water (ESW) piping was replaced. In the same period, Exelon replaced 20% of underground Service Water (SW) piping. The licensee plans to rehabilitate recondition, or replace the remaining 80 percent in the future.
- In 2006, approximately 1000 linear feet of fuel oil transfer piping was replaced with double-walled pipe. Leak detection monitors were also installed.
- In 2008, Exelon replaced all underground chlorination lines to the ESW and SW systems.
In addition to programmatic inspection activities, underground piping inspections are performed when opportunities arise. For example, the excavation to examine potential leaking pipes in April 2009, provided an opportunity to inspect all of the buried piping contained in that area.
Inspection is also accomplished by the licensees Inservice Testing program using flow surveillances of various systems that contain underground piping to demonstrate system integrity. Such testing can reveal flow anomalies caused by buried pipe leakage. In 2008, the applicable testing procedures were revised to consider the potential for leakage in six systems containing underground piping.
Question 6:
What did the licensee find as a result of this inspection?
Answer 6:
The 2008 buried piping inspection, as discussed in the response to Question 5, identified no degradation of the inspected segments of piping.
The most recent inspection, performed after identifying elevated levels of tritium in the Emergency Service Water System cable vault, identified two areas of leakage from piping in the Condensate System. The leaking sections of pipe, which preliminarily have been determined to be the cause of the tritium found in the Emergency Service Water System vault, were promptly replaced by Exelon. The leakage noted was small and thus not identified by flow testing or by a drop in Condensate Storage Tank level. As discussed in the response to Question 1, an additional barrier for the detection of leakage in buried pipes is Exelons program to monitor groundwater conditions onsite. It was the groundwater monitoring program that identified the tritium leakage. Exelon is performing a root cause evaluation of this issue.
The NRC is currently inspecting and reviewing this issue to assess Exelons implementation of its underground piping inspection program. The results of this inspection will be documented in a publicly available NRC Inspection Report.
Question 7:
Why did the licensee not find evidence of faulty piping?
Answer 7:
The licensee identified the leaking piping through its environmental monitoring programs. The identification of elevated tritium levels in onsite groundwater monitoring wells prompted Exelon to conduct additional inspections, including excavating areas of buried pipe suspected of leaking. As discussed in the response to Question 6, the leakage noted was small and thus not identified by flow testing or a drop in Condensate Storage Tank level.
The NRC is currently inspecting this issue, including a review of the Exelons conduct of its underground piping inspection program. The results of this inspection will be documented in a publicly available NRC Inspection Report.
Question 8:
Do you believe that the tritium leaks are caused by corrosion from inside the pipes, outside the pipes, or both?
Answer 8:
Although leakage can be caused by many different mechanisms, a common cause of leakage is external corrosion of the pipe that occurs when the protective coating on the exterior fails and adverse soil conditions come in contact with the piping. Corrosion of the inside of pipes is more common in those pipes that carry natural water sources with uncontrolled chemistry (e.g., salt water).
Exelons root cause and extent of condition review, including laboratory analysis of the affected piping, is still in progress. The NRC is currently inspecting this area and will review and assess the cause of the corrosion in the publicly available NRC Inspection Report.
Question 9:
Has the Commission ever considered requiring licensees to develop technologies and methods to inspect difficult-to-access buried pipe? If so, have these requirements been implemented? If not, why not?
Answer 9:
The NRC continues to review the operating experience at nuclear power plants and has considered many different technologies and methods for inspection of components. To date, the experience with buried piping systems has indicated only minor problems that do not justify expansion of the current NRC regulations. New corrosion-resistant materials continue to be evaluated, and as an example, the NRC has recently approved the use of high density polyethylene pipe in certain buried systems.
The NRC requires licensees to implement an inservice inspection program that complies with the ASME Code requirements for safety-related piping. Where applicable, the licensees buried pipe aging management program also prescribes techniques for examining the buried pipes.
Licensees are also exploring new technologies on their own initiative to detect leakage and corrosion before piping failures occur.
Degradation that is detected in buried piping is evaluated and addressed by the licensees corrective action programs. The NRC has a program to evaluate operating experience and disseminate the information to licensees. If an issue is significant, the agency can evaluate it under our Generic Issues program for further regulatory action. The NRC will continue to evaluate operating experience with buried piping and will take further regulatory or enforcement actions as warranted.