Robert, I talked to the applicant and everything that is in red and underlined is new or added to the application.

They are sending a working version (see attached) of the response to expedite our review, the formal letter will come tomorrow or Monday. I'm also going to confirm this facts with them. The front portion of the response corresponds to Ron Young (scoping), as a result of his request the applicant had to revised the AMR tables and add more mechanical systems components.

What I need from you:

1. Please check the attachment and let me know the extent of the work for these new AMR tables
2. Promptly notification of the reviewers responsible for Section 3.3.2
3. Identify if any items do not correspond to the audit review.
4. Notify me if we need to address any items with the applicant
5. Notify if we might have potential open items I will appreciate your prompt response in this matter. Just a friendly reminder the SER due date is Wednesday. August 1st (next week), therefore your prompt action is critical!

Thanks in advance, Yoira CC:

bhr@nrc.gov; Jonathan Rowley; Rajender Auluck; Ron Young

.I.- --.-

..I......

F I-c:ýtemp\\GW)00003.TMP Page 1 I

[I c:\\temp\\GW}00003.TMP Page 1 I Mail Envelope Properties (46A8DDEO.91A :20: 35820)

Subject:

Creation Date From:

Created By:

Revised AMR tables 07/26/2007 1:46:08 PM Yoira Diaz Sanabria YKS(onrc.gov Recipients nrc.gov OWGWPOO1.HQGWDOO1 RCA CC (Rajender Auluck) nrc.gov OWGWPOO4.HQGWDOOI KRH2 (Kaihwa Hsu) nrc.gov TWGWPO03.HQGWDOOI BHR CC (Billy Rogers)

JGR CC (Jonathan Rowley) nrc.gov TWGWPO04.HQGWDOOI RMY CC (Ron Young)

Post Office OWGWPOO1.HQGWDOO1 OWGWPOO4.HQGWDOOI TWGWPO03.HQGWDOOI TWGWPO04.HQGWDOOI Route nrc.gov nrc.gov nrc.gov nrc.gov Files Size MESSAGE 1965 BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc PM Options Expiration Date:

None Priority:

Standard ReplyRequested:

No Return Notification:

Send Notification when Opened Send Notification when Deleted Date & Time 07/26/2007 1:46:08 PM 1822208 07/26/2007 1:31:40

I c:\\temp\\GW}00003.TMPP Page 2 '1 Concealed

Subject:

No Security:

Standard Junk Mail Handling Evaluation Results Message is not eligible for Junk Mail handling Message is from an internal sender Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled

Jonaýhah Rowley - BW 01-064 Aft ý2 - 54..4(a.2 S.. copi.n.g 2.Am Page 1, Jonathan Rowley - BVY 07-054 Att2 - 54.4(a)(2) Scoping2.doc Page 1 I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 License Renewal Application Changes Page 1 of 63 BVY 07-054 Docket 50-271

ionathan Rowley - BVY 07-'054 Att 2 - 54.4(a)(2') Scoping_2.doc Pageý 2 ý Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 2 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 The following information is provided as a supplement to the previously submitted License Renewal Application. The need for this information was identified as a Safety Evaluation Report (SER) Confirmatory Item.

Note: Insertions = underlined, deletions = strike-through Nonsafety-Related Components Affecting Safety-Related Systems Subject to Aging Management Review The following is provided to clarify the systems which are included in the scope of license renewal.

Table 2.2-1a is revised to include the following new information:

Table 2.2-1a Mechanical Systems within the Scope of License Renewal System Code System Code Name LRA Section 103 HD & HV Instruments Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

AE Air Evacuation Section 2.3.3.13, Miscellaneous Systems in

____________________Scope for (a)(2)

BLD Buildinq (drainagqe system Section 2.3.3.13, components)

Miscellaneous Systems in

____________________Scope for (a)(2)

CWP Circulatinq Water Primingq Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

ES Extraction Steam Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

HOD Heater Drain Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

HV Heater Vent Section 2.3.3.13, Miscellaneous Systems in

_____________________Scope for (a)(2)

HWC Hydrogen Water Chemistry Section 2.3.3.13, Miscellaneous Systems in

___________________Scope for (a)(2)

MUD Make-up Demineralizer Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

Page 2 of 63 BVY 07-054 Docket 50-271

imathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page.

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 3 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 SO Seal Oil Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

TBCCW Turbine Building Closed Cooling Section 2.3.3.13, Water Miscellaneous Systems in Scope for (a)(2)

TG Main Turbine Generator Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(21 TLO Turbine Lube Oil Section 2.3.3.13, Miscellaneous Systems in I

Scope for (a)(2)

> The mechanical systems added to Table 2.2-1a (above) are hereby removed from Table 2.2-2 "Mechanical Systems Not within the Scope of License Renewal" Page 3 of 63 BVY 07-054 Docket 50-271

Jona....han....Row...ey......BVY.07-054.

Att....2..............

S....p..ng.

do....Page....4 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc

.P~age 4.

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 The following is provided to clarify the description of systems which are included in the scope of license renewal.

> Table 2.3.3.13-A is revised to include the following new information:

Table 2.3.3.13-A Systems within the Scope of License Renewal based on the Potential for Physical Interaction with Safety-Related Components (10 CFR 54.4(a)(2))

System Code System Name Section with System Description 103 HD & HV Instruments Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

AE Air Evacuation Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

AS Auxiliary Steam Section 2.3.4.1, Auxiliary Steam BLD Buildinq (drainaqe system Section 2.3.3.13, components)

Miscellaneous Systems in Scope for (a)(2)

CWP Circulatingq Water Primingq Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

ES Extraction Steam Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

HD Heater Drain Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

HV Heater Vent Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

HWC Hydrogqen Water Chemistry Section 2.3.3.13, Miscellaneous Systems in

_ Scope for (a)(2)

M__S Main Steam Section 2.3.4.3, Main Steam MUD Make-up Demineralizer Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

SA Service Air Section 2.3.3.7, Instrument Air Page 4 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - 8W b7-O54 Att'2 - 54.4(aý(2) Scoping-2. doc

-Page 6'1 Jo n a a n

......ey...............

A tt. 2 -............

n g P a ge..

5 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 SO Seal Oil Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

TBCCW Turbine Buildinq Closed Cooling Section 2.3.3.13, Water Miscellaneous Systems in Scope for (a)(2)

TG Main Turbine Generator Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

TLO Turbine Lube Oil Section 2.3.3.13, Miscellaneous Systems in Scope for (a)(2)

LRA Section 2.3.3.13.2 is revised to add descriptions of scope of license renewal as follows.

systems newly added to the HD & HV Instruments The purpose of the 103 system is to provide indication, alarm, and control functions for associated systems (heater drains and heater vents).

Air Evacuation The purpose of the AE system is to evacuate gases from the main turbine and main condenser during startup and maintain the system free of noncondensible gases during operation.

Building (drainage system components)

The BLD system includes floor drains and the site sewers. This system classification also designates buildings and structures which are evaluated in Section 2.4 of this LRA..

Circulatinq Water Priming The purpose of the CWP system is to provide for evacuation of the discharge side of the main condenser.

Extraction Steam The purpose of the ES system is to supply steam to the shell side of various feedwater heaters for condensate and feedwater heating.

Heater Drain Page 5 of 63 BVY 07-054 Docket 50-271

Jonathan.....R ow ley......B..............

tt........

Sc.. p...

2.doc...

Page....

6 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page. 6]i VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 The purpose of the HD system is to provide proper level and control for the moisture separator and feedwater heaters by providing drain capability to the main condenser.

Heater Vent The purpose of the HV system is to provide for venting of non-condensable gases back to the main condenser.

HydroQen Water Chemistry The purpose of the HWC system is to mitigate the chemical conditions in the reacior that allow IGSCC in the recirculation piping and reactor vessel internals. The HWC system injects hydrogen into the reactor feedwater at the suction of the feedwater pumps.

Make-up Demineralizer The purpose of the MUD system is to provide a supply of treated water to the DW system that may be used as makeup for the station and reactor cycles.

Seal Oil The purpose of the SO system is to provide shaft sealing for the main generator.

Turbine Buildinq Closed Coolinq Water The purpose of the TBCCW system is to supply demineralized water to cool various nonsafety-related auxiliary equipment located in the turbine building in support of power generation Main Turbine Generator The purpose of the TG system is to convert the thermodynamic energy of steam into a reliable source of electrical energy for use on the transmission network and the station auxiliary busses.

Turbine Lube Oil The purpose of the TLO system is to provide lube oil for lubrication of the main turbine.

Page 6 of 63 BVY 07-054 Docket 50-271

Rowley - BVY 07-0'54'Att 2 - 54.4(a)(2) Scoping_2.doc Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 7 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 The following is provided to clarify the description of components subject to aging management review which are to be included in aging management programs during the period of extended operation.

0 Table 2.3.3.13-B is revised to include the following new information:

Table 2.3.3.13-B Description of Nonsafety-Related System Components Subject to Aging Management Review Based on 10 CFR 54.4(a)(2) for Physical Interactions System Code Nonsafety-Related Components Subject to AMR 103 Portion of the system in the turbine buildinq AE Portion of the system in the turbine building AOG Portion of the system inside associated-withthe plant stack leep-seal-structure AS Portion of the system in the turbine building BLD The portion of the system in the reactor building and the turbine building C

Portion of the system at the ECCS keep full station in the turbine building, as well as the area On ele.Vation, o25o2 in the turbine building vhore e-r*,iGe ter piingn ru*ns F

along the wall.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

CD Portion of the system in the turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

CST Portion of the system in the CST valve and instrument enclosure, the primary containment building, and the reactor building, and the turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

Page 7 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 -'54.4-(a)(?.)

Scoping_2.d0oc Pe Page 81 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 CW Portion of the system in cooling tower #2 cell 1 and the turbine building.

CWP Portion of the system in the turbine building DG Portion of the system in tho dieel generator roome in the turbine building Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

DW Portion of the system in the control building, the reactor building, and at tho, die.el generato rooms in the turbine building and in the CST valve and instrument enclosure.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

ES Portion of the system in the turbine building FDW Portion of the system in the reactor building and in primary containment and the turbine buildingq FO Portion of the system in the fuel oil transfer pump house and the turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

FP Portion of the system in cooling tower #2 cell 1 and the reactor building, the turbine building, and the service water pump area of the intake structure.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

HB Portion of the system in the CST valve and instrument enclosure, the control building, the reactor building, and at the diesel generator reemA6 in the turbine building Components outside the safety class pressure boundary yet relied upon to provide structural/seismic support for the pressure boundary.

HID Portion of the system in the turbine building Page 8 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 9.1 I J a

....... y..07-054.Att..2........................

.P age.9 I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 HV Portion of the system in the turbine buildinq HVAC Portion of the system in the reactor building and the turbine building.

Components outside the safety class pressure boundary yet relied upon to provide structural/seismic support for the pressure boundary.

HWC Portion of the system in the turbine building IA The portion of the system in the reactor building and the turbine building that requires aging management review due to potential spatial interaction are the cooling and lubrhicration subcomponents for the cona'ntainment air compressor (G 2 4 A) and its precoler and aftercoo)er, as well as. the air dryer towers (tanks), drain piping, valves, and traps associated with the instrument air dryers (D-1-IA and D-1 -1 B) and the containment air dryer (D-2-1 A), as well as the drain piping, valves, and traps associated with the air receiver tank and knock-out drum (TK-55-1A and TK-154-lA).

Components outside the safety class pressure boundary yet relied upon to provide structural/seismic support for the pressure boundary.

MS Portion of the system in the turbine building MUD Portion of the system in the turbine building PASS Portion of the system in the reactor building and the turbine building Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

PW Portion of the system in the "A" diesel gener-ator room in the turbine building RDW Portion of the system in the CST valve and instrument enclosure, service water pump area of the intake structure, plant stack, primary containment building, and reactor building and turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

RHRSW Portion of the system in the reactor building and the turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

Page 9 of 63 BVY 07-054 Docket 50-271

ý Jonathaq Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 10 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 10 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 SA The portion of the system in the turbine buildinq that requires aging management review due to potential spatial interaction includes the drain piping, valves, and traps associated with the air receiver tanks (TK-5-1A and TK-5-1 B).

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

SC Portion of the system in the turbine building Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

SO Portion of the system in the turbine building SPL Portion of the system in the reactor building, turbine building, and plant stack.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

SW Portion of the system in the service water pump area of the intake structure and the reactor building and the turbine building.

Components outside the safety class pressure boundary, yet relied upon to provide structural/seismic support for the pressure boundary.

TBCCW Portion of the system in the turbine building TG Portion of the system in the turbine building TLO Portion of the system in the turbine building Page 10 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 01-054 Att 2 64.4(a')(2) S-c'oping-_2--.d6c Page 1 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2)Scoping2.doc Page lii VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 The following is provided to clarify the description of components subject to aging management review which are to be included in aging management programs during the period of extended operation.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-43, HD & HV Instruments (103) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Piing Pressure boundary TubinQ Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 11 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 01-o64 Att 2 - 64.4(a')(2-)-'S'co-ping_'2-'.d-o'c Page i2:1 I Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 12; VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-44, Air Evacuation (AE)

System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary Heat exchanger Pressure boundary (shell)

Piping Pressure boundary Pump casing Pressure boundary Rupture disk Pressure boundary Strainer housing Pressure boundary Trap Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

> LRA Table 2.3.3-13-1, Augmented Offgas (AOG) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line item.

Component Type Intended Function1 Steam trap Pressure boundary

1. For component types included under.10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 12 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping-2.doc Page 13 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-45, Auxiliary Steam (AS)

System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Heat exchanger Pressure boundary (shell)

Pitc Pressure boundary Stream trap Pressure boundary Tubing Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-46, Building (drainage system components) System (BLD), Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Piping Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 13 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - 8VY-01-054 Att 2 - 54.4(a)ý2) Scoping_2.doc P.age. 1_4 1 J o n a th a n.

R...wle y.....

Att..

2 -.

.P..

.g..

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Table 2.3.3-13-2, Condensate (C) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Heat exchanger Pressure boundary (shell)

Orifice Pressure boundary Pump casingq Pressure boundary Steam trap Pressure boundary Tank Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

> LRA Table 2.3.3-13-4, Condensate Demineralizer (CD) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary Pump casing Pressure boundary Tank Pressure boundary Tubing Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 14 of 63 BVY 07-054 Docket 50-271

Jonathan R.Owley..-..B.VY-'01-0.6.4.At.i-21.---.ý.64...4(a)(2ý 8copi'ng_2.doc Jonathan Rowley - BVYO7-054Att2-54.4(a)(2) Scoping2.doc Page 15 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Table 2.3.3-13-7, Condensate Storage and Transfer (CST) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line item.

Component Type Intended Function1 Filter housinq Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-9, Circulating Water (CW) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Expansion joint Pressure boundary Tank Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 15 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - 8\\/Y 01-054 Att 2 - 54.4(a)(2) Scoping_2..d.o.c..

Page 16:1 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 16 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-47, Circulating Water Priming (CWP) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Pin Pressure boundary Pump casing Pressure boundary Tank Pressure boundary Trap Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

> LRA Table 2.3.3-13-10, Diesel Generator and Auxiliaries (DG) System, Nonsafety-.

Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised to delete the following line item.

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 16 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc P age 1!71 I J n t a o

l y

- B Y 0 -

5 t

P a ge....

.........1 7!..

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-48, Extraction Steam (ES)

System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Expansion joint Pressure boundary Orifice Pressure boundary Piping Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-13, Feedwater (FDW) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Heat exchanger Pressure boundary (shell)

Orifice Pressure boundary Pump casing Pressure boundary Strainer housing Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 17 of 63 BVY 07-054 Docket 50-271

[Jnta oly-BY0-5At25.()2 cpn2dcPg 8

Jonathan Rowley - BVY 07-054 Att..2 54.4(a)(2). S.coping_2..d.oc Page 16;1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Table 2.3.3-13-14, Fuel Oil (FO) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line item.

Component Type Intended Function1 Strainer housinq Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-15, Fire Protection (FP) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Orifice Pressure boundary Strainer housinq Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-18, House Heating Boiler (HB) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function' Heat exchanqer Pressure boundary (shell)

Strainer housingq Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-relatedSSCs directly connected to safety-related SSCs.

Page 18 of 63 BVY 07-054 Docket 50-271

Jonathan.

Rowley.

V...07-054.....A..t..2..........()

c png

.o a e 19 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) ScopingJ.doc Page..19. 1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

' LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-49, Heater

System, Nonsafety-Related Components Affecting Safety-Related Components Subject to Aging Management Review, as follows.

Drain (HD)

Systems-Component Type Intended Function1 Bolting Pressure boundary ping Pressure boundary Pump casingq Pressure boundary Tank Pressure boundary Tubingi Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-50, Heater Vent (HV) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Orifice Pressure boundary PinPressure boundary Tank Pressure boundar Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 19 of 63 BVY 07-054 Docket 50-271

-Jonathan. Rowley - BVy 07-054 Att 2O-54.4(a)(2) Scoping_2.doc Page. 20 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Table 2.3.3-13-21, Heating, Ventilation, and Air Conditioning (HVAC) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items and deleting one line item.

Component Type Intended Function1 Duct Pressure boundary Fan housinq Pressure boundary Heat exchanger Pressure boundary (shell)

Heat8hane-Pressure bou nda*y Pump casing Pressure boundary Strainer housingi Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-51, Hydrogen Water Chemistry (HWC) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary PinPressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 20 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2-54.4(a)(2) Scopin.g_2.doc Page 21 :1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Table 2.3.3-13-22, Instrument Air (IA) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised to delete the following line item.

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-52, Main Steam (MS) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Heat exchanqer Pressure boundary (shell)

Orifice Pressure boundary ElalnQ Pressure boundary Strainer housinq Pressure boundary Tubinq Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 21 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-064 Att 2 - 64'.4(a)(2) Scoping.2.doc Page,4]

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 22 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-53, Make-up Demineralizer (MUD) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary Piping Pressure boundary Pump casing Pressure boundary Tank Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-29, Potable Water (PW) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Filter housing Pressure boundary Strainer housing Pressure boundary Tank Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 22 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY07-054 Att 2 -*,.4(a)(2)

Scoping_2.doc Page 23*

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

>' LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-54, Service Air (SA) System, Nonsafety-Related Components Affecting Safety-Related System s-Com ponents Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Piping Pressure boundary Tank Pressure boundary Trap Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Table 2.3.3-13-39, Stator Cooling (SC) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line items.

Component Type Intended Function1 Boltinq Pressure boundary Filter housing Pressure boundary Heat exchanger Pressure boundary (shell)

Pump casing Pressure boundary Strainer housinq Pressure boundary Tank Pressure boundary Tubing Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 23 of 63 BVY 07-054 Docket 50-271

Jlonathýaq Rowley - BVY 07-054 Att 2 - 54.4(a)(2). Sco.pin.gý2..do.c Page 24 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 24 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-55, Seal Oil (SO) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary PicPressure boundar Pump casing Pressure boundary Sight glass Pressure boundary Tank Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

> LRA Table 2.3.3-13-41, Sampling (SPL) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line item.

Component Type Intended Function1 Strainer housing Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 24 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - B VY 07-054 A tt 2 - 54.4(a)( 2)S copi ng 2.doc I

Page 25

[Jonathan Rowley - BVY 07-054Att2-54.4(a)(2) Scopihg2.doc Page 25 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Table 2.3.3-13-42, Service Water (SW) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, is revised adding the following line item.

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included~for nonsafety-related SSCs directly connected to safety-related SSCs.

LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-56, Turbine Building Closed Cooling Water (TBCCW) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Heat exchanger Pressure boundary (shell)

Piin Pressure boundary Pump casing Pressure boundary Tank Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 25 of 63 BVY 07-054 Docket 50-271

[Jonathan Rowley - BVY 07-054 Att 2 54.4(a)(2) Scoping2.doc Page 26 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) ScopingJAbc

.Pa~ge.26 J VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-57, Main Turbine Generator (TG) System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary Piping Pressure boundary Pump casing Pressure boundary Turbine casing Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 26 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 271 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 2.3.3 is revised to add a new Table 2.3.3-13-58, Turbine Lube Oil (TLO)

System, Nonsafety-Related Components Affecting Safety-Related Systems-Components Subject to Aging Management Review, as follows.

Component Type Intended Function1 Bolting Pressure boundary Filter housing Pressure boundary Heat exchanger Pressure boundary (shell)

Pipin Pressure boundary Pump casing Pressure boundary Strainer housing Pressure boundary Tank Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

1. For component types included under 10 CFR 54.4(a)(2), the intended function of pressure boundary includes providing structural/seismic support for components that are included for nonsafety-related SSCs directly connected to safety-related SSCs.

Page 27 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley BVY 01-064'Att'2 - 5'4'.-4"(a)(2) S'coping_2:00.c".

Pa ge 28 I Jonathan Rowley - BVY 07-054 Att2 - 54.4(a)(2) Scoping2.doc Page 28 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-43, HD & HV Instruments (103) System, Nonsafety-Related Components Affecting Safety-Related Systems -

Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air-indoor Loss of System VI.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Piping Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-10)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Valve Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Treated water Loss of Water VIIIE-3.4.1-4 A

body boundary steel (int) material Chemistry 33 1

1 Control - BWR (S-09)

Page 28 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping 2.doc Page 29 1 Jona.h..

ol

.y..

07 054.Att.2......(....)..co.n...d.

..... 29 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-44, Air Evacuation (AE)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air - indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Filter Pressure Carbon Air - indoor Loss of System V1I.l-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

housing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Heat Pressure Carbon Air-indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

exchanger boundary steel (int) material Chemistry 18 (shell)

Control - BWR (A-35)

Piping Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Treated water Loss of Water VI1.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Pump Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

casing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Rupture Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-57 A

disk boundary steel (ext) material Walkdown (A-77)

Rupture Pressure Carbon Treated water Loss of Water VIII.A-3.4.1-4 C

disk boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Strainer Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

housing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Trap Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Trap Pressure Carbon Treated water Loss of Water VIIIE-3.4.1-4 A

boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Tubing Pressure Copper Air-indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-1 0)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Page 29 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_,2.doc Page 30 1i Jon thn..wly..BV.0705.At.2 4().

c pn 2d cP g

3Q VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Page 30 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 31 SJornathan Rowley - BVY 07-054 Att 2 -.54.4(a)(2) Scoping_2.doc Page 31 ý VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2, Table 3.3.2-13-1, Augmented Offgas (AOG) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table I Notes Type Function Requiring Management

1801, Item Management Programs Vol,2 Item Piping Pressure Carbon Steam > 220'F Loss of Flow VIIIA-3.4.1-29 C

boundary steel (int) material accelerated 17 corrosion (S-15)

Piping Pressure Carbon Steam > 220'F Loss of Water VIII.A-3.4.1-2 C

boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Piping Pressure Carbon Steam > 220°F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Steam Pressure Carbon Air - indoor Loss of System V.E-7 3.2.1-31 A

trap boundary steel (ext) material Walkdown (E-44)

Steam Pressure Carbon Steam > 220°F Loss of Water VIIlA-3.4.1-2 C

trap boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Steam Pressure Carbon Steam > 220'F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

trap boundary steel (int) fatigue fatigue 5

(S-08)

Steam Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

trap boundary steel

> 220'F (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Air - indoor Loss of System V.E-7 3.2.1-31 A

body boundary steel (ext) material Walkdown (E-44)

Valve Pressure Carbon Steam > 220'F Loss of Flow VIII.A-3.4.1-29 C

body boundary steel (int) material accelerated 17 corrosion (S-15)

Valve Pressure Carbon Steam > 220°F Loss of Water VIlI.A-3.4.1-2 C

body boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Valve Pressure Carbon Steam > 220'F Cracking -

TLAA - metal V.D2-32 3.2.1-1 A

body boundary steel (int) fatigue fatigue (E-10)

Valve Pressure Carbon Treated water Loss of Water VIIlE-3.4.1-4 A

body boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Valve Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

body boundary steel

> 220'F (int) fatigue fatigue 5

1_

1 1

1 1

(S-08)

Page 31 of 63 BVY 07-054 Docket 50-271

Jonathan Row ley......BVY...........tt.

4(

) 2 S o i g....

.Pag..........

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc 11 --.- I~ -.......

1.1 -- ý........

Page 32:1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-45, Auxiliary Steam (AS)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.l-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Heat Pressure Carbon Air-indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Treated water Cracking -

One-Time H

exchanger boundary steel

> 220°F (int) fatigue Inspection (shell)

Heat Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

exchanger boundary steel (int) material Chemistry 18 (shell)

Control - BWR (A-35)

Piping Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Steam > 220'F Loss of Flow VIII.A-3.4.1-29 C

boundary steel (int) material accelerated 17 corrosion (S-15)

Piping Pressure Carbon Steam > 220'F Loss of Water VIII.A-3.4.1-2 C

boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Piping Pressure Carbon Steam > 220°F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Steam Pressure Carbon Air - indoor Loss of System V.E-7 3.2.1-31 A

trap boundary steel (ext) material Walkdown (E-44)

Steam Pressure Carbon Steam > 220'F Loss of Flow VIII.A-3.4.1-29 C

trap boundary steel (int) material accelerated 17 corrosion (S-15)

Steam Pressure Carbon Steam > 220°F Loss of Water VIII.A-3.4.1-2 C

trap boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Steam Pressure Carbon Steam > 220 0F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

trap boundary steel (int) fatigue fatigue 5

(S-08)

Steam Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

trap boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Steam Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

trap boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tubing Pressure Carbon Air - indoor Loss of System V.E-7 3.2.1-31 A

boundary steel (ext) material Walkdown (E-44)

Page 32 of 63 BVY 07-054 Docket 50-271

I jonathan Rowley - BVY 07-054 Att 2 -54.4(a)(2') Scoping_2'.doc

.Page 33]

I J n t a o

l y B Y 0 -

5 t

P age...

.....33....

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Tubing Pressure Carbon Steam > 220'F Loss of Flow V.D2-31 3.2.1-19 A

boundary steel (int) material accelerated (E-07) corrosion Tubing Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Valve Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Steam > 220°F Loss of Flow VIll.A-3.4.1-29 C

body boundary steel (int) material accelerated 17 1

corrosion (S-15)

Valve Pressure Carbon Steam > 220°F Loss of Water VIll.A-3.4.1-2 C

body boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Valve Pressure Carbon Steam > 220'F Cracking -

TLAA - metal V.D2-32 3.2.1-1 A

body boundary steel (int) fatigue fatigue (E-10)

Valve Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

body boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Treated water Loss of Water VIIIE-3.4.1-4 A

body boundary steel (int) material Chemistry 33 Control - BWR (S-09)

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-46, Buildings (drainage system components) System (BLD), Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table I Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Piping Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Untreated Loss of Periodic VII.G-24 3.3.1-68 E

boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Page 33 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scopingj.do.c I

Page 34 KJonathan Rowley-BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 34 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-2, Condensate (C) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Heat Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

exchanger boundary steel (ext) material Walkdown (S-29)

(shell)

Heat Pressure Carbon Treated water Cracking -

One-Time H

exchanger boundary steel

> 220oF (int) fatigue Inspection (shell)

Heat Pressure Carbon Treated water Loss of Water VIII.E-7 3.4.1-5 A

exchanger boundary steel (int) material Chemistry (S-18)

(shell)

Control - BWR Orifice Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Orifice Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Piping Pressure Carbon Steam > 220'F Loss of Water VIII.A-3.4.1-2 A

boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Piping Pressure Carbon Steam > 220°F Loss of Flow VIII.B2-3.4.1-29 C

boundary steel (int) material accelerated 4

corrosion (S-15)

Piping Pressure Carbon Steam > 220'F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Pump Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

casing boundary steel (ext) material Walkdown (S-29)

Pump Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

casing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Steam Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

trap boundary steel (ext) material Walkdown (S-29)

Steam Pressure Carbon Steam > 220'F Loss of Flow VIII.B2-3.4.1-29 C

trap boundary steel (int) material accelerated 4

corrosion (S-15)

Steam Pressure Carbon Steam > 220°F Loss of Water VIII.A-3.4.1-2 A

trap boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Steam Pressure Carbon Steam > 220'F Cracking -

TLAA - metal

'VIII.B2-3.4.1-1 C

trap boundary steel (int) fatigue fatigue 5

(S-08)

Steam Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

trap boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Steam Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

trap boundary steel

> 220'F (int) fatigue fatigue 5

J

_(S-08)

Page 34 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 35 1 Jonathan.......Row le...y.............07-054............2..........

4)(

) S pi g...................P..

.ge..

35 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Page 35 of 63 BVY 07-054 Docket 50-271

[jonathan Rowley-BVY 07-054 Att 2 - 54.4(a)(2) Scoping-2.d oc Page 36 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

). LRA Section 3.3.2, Table 3.3.2-13-4, Condensate Demineralizer (CD) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Type Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG-

1801, Vol.2 Item Table 1 Item Notes Bolting Pressure Carbon Air - indoor Loss of System VIII.H-4 3.4.1-22 E

boundary steel (ext) material Walkdown (S-34)

Bolting Pressure Stainless Air - indoor None None VIII.I 10 3.4.1-41 C

boundary steel (ext)

(SP-1 2)

Filter Pressure Carbon Air - indoor Loss of System V1I.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Filter Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

housing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Pump Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

casing boundary steel (ext) material Walkdown (S-29)

Pump Pressure Carbon Treated water Loss of Water VIIlE-3.4.1-4 A

casing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Tank Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Tank Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Tubing Pressure Copper Air - indoor None None VI11.1-2 3.4.1-41 A

boundary alloy <

(ext)

(SP-6) 15% Zn Tubing Pressure Copper Treated water Loss of Water VIIlA-5 3.4.1-15 C

boundary alloy <

(int) material Chemistry (SP-61) 1 15% Zn Control - BWR Page 36 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 37 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

)o LRA Section 3.3.2, Table 3.3.2-13-7, Condensate Storage and Transfer (CST) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Filter Pressure Carbon Air - outdoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Filter Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

housing boundary steel (int) material Chemistry 33 Control -. BWR (S-09)

LRA Section 3.3.2, Table 3.3.2-13-9, Circulating Water (CW) System, Nonsafety-Related Components Affecting Safety-Related Systems

- Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Expansion Pressure Stainless Condensation Loss of System VI1.1-1 1 3.3.1-58 A

joint boundary steel (ext) material Walkdown (A-81)

Expansion Pressure Stainless Raw water (int)

Loss of Periodic VII.G-24 3.3.1-68 E

joint boundary steel material Surveillance (A-33) and Preventive Maintenance Tank Pressure Carbon Condensation Loss of System VII.l-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Raw water (int)

Loss of Periodic VII.G-24 3.3.1-68 E

boundary steel material Surveillance (A-33) and Preventive Maintenance Page 37 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 5.4..4(.. a.. (2 S c opi.n g 2.do c Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 38~

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-47, Circulating Water Priming (CWP) System, Nonsafety-Related Components Affecting Safety-Related Systems -

Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.l-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Carbon Air - outdoor Loss of System VII.l-1 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-28)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Bolting Pressure Stainless Air - outdoor None None G

boundary steel (ext)

Piping Pressure Carbon Condensation Loss of System VIII.H-3.4.1-28 A

boundary steel (ext) material walkdown 10 (S-42)

Piping Pressure Carbon Raw water (int)

Loss of Periodic VIII.E-6 3.4.1-31 E

boundary steel material Surveillance (S-24) and Preventive Maintenance Pump Pressure Carbon Condensation Loss of System VIII.H-3.4.1-28 A

casing boundary steel (ext) material walkdown 10 (S-42)

Pump Pressure Carbon Raw water (int)

Loss of Periodic VIII.E-6 3.4.1-31 E

casing boundary steel material Surveillance (S-24) and Preventive Maintenance Tank Pressure Carbon Condensation Loss of System VIII.H-3.4.1-28 A

boundary steel (ext) material walkdown 10 I_

(S-42)

Tank Pressure Carbon Raw water (int)

Loss of Periodic VIII.E-6 3.4.1-31 E

boundary steel material Surveillance (S-24) and Preventive Maintenance Trap Pressure Carbon Condensation Loss of System VIII.H-3.4.1-28 A

boundary steel (ext) material walkdown 10 I

_(S-42)

Trap Pressure Carbon Raw water (int)

Loss of Periodic VIII.E-6 3.4.1-31 E

boundary steel material Surveillance (S-24) and Preventive Maintenance Tubing Pressure Copper Condensation Loss of System VII.F1-3.3.1-25 E

boundary alloy <

(ext) material walkdown 16 15% Zn (A-46)

Tubing Pressure Copper Rawwater (int)

Loss of Periodic VIlI.E-3.4.1-32 E

boundary alloy <

material Surveillance.

18 15% Zn and Preventive (SP-31)

Maintenance I

Valve Pressure Carbon Condensation Loss of System VIII.H-3.4.1-28 A

body boundary steel (ext) material walkdown 10 I_

I_

I I(S-42)

Page 38 of 63 BVY 07-054 Docket 50-271

Jqnathaý Rowley - BW 07-054 Att 2 - 54.4(a)(2) Scoping'_2.'doic

..P ag e 3.I I

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 39 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Valve Pressure Carbon Raw water (int)

Loss of Periodic VIII.E-6 3.4.1-31 E

body boundary steel material Surveillance (S-24) and Preventive Maintenance Page 39 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY. 7.-054 At.2t.2.-

2.5.4.4(a.)( 2) Scoping 2.doc

... Pag...e 40 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2, Table 3.3.2-13-10, Diesel Generator & Auxiliaries (DG) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised to delete the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item COM,.e.SO.

PF. -es aFben AO L-ess-ef-Sytem-VIj42-3.3 8 A

.4 steel mafte Wak..W. R CEoFmpe6GF-FPie66~e-GaFbOR-TFeated-wateF-L6 O~-f-Watef VIk.H2-331-4-7 9

h0U6!Rgi beunday steel m4 FateFal GhemistFy-23 Glesed-Ce.. Fe6..F.

P-esFe-s "o

U e.ted. a I Aess-e.-

Per-edG W-Vl12-437-4

.- heusOR9 beU*da steel Omaterial S'-,"-cilnRAe_

24 aRd P'eventi-A-23

~~mawieap e

Page 40 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley.- BVY 0-7-054 Att 2 - 54.4 (a) (2) Scopi ng_2..docPe Page 41 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-48, Extraction Steam (ES)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table I Notes Type Function Requiring Management

1801, Item Management Programs Vol.2

.Item Bolting Pressure Carbon Air - indoor Loss of System VI11.H-4 3.4.1-22 E

boundary steel (ext) material Walkdown (S-34)

Bolting Pressure Stainless Air - indoor None None VIII.-10 3.4.1-41 C

boundary steel (ext)

(SP-12)

Expansion Pressure Stainless Air-indoor None None VIII.1-10 3.4.1-41 A

joint boundary steel (ext)

(SP-1 2)

Expansion Pressure Stainless Steam > 270"f Loss of Water VIIlA-3.4.1-37 C

joint boundary steel (int) material Chemistry 13 Control - BWR (SP-46)

Expansion Pressure Stainless Steam > 270"f Cracking -

TLAA - metal H

joint boundary steel (int) fatigue fatigue Expansion Pressure Stainless Steam > 270°f Cracking Water VIII.B2-3.4.1-13 A

joint boundary steel (int)

Chemistry 1

Control - BWR (SP-45)

Expansion Pressure Stainless Treated water Cracking Water VIllA-3.4.1-13 C

joint boundary steel

> 270'f (int)

Chemistry 11 Control - BWR (SP-45)

Expansion Pressure Stainless Treated water Cracking -

TLAA - metal H

joint boundary steel

> 270°f (int) fatigue fatigue Expansion Pressure Stainless Treated water Loss of Water VIII.C-1 3.4.1-16 A

joint boundary steel

> 270'f (int) material Chemistry (SP-16)

Control - BWR Orifice Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Orifice Pressure Carbon Steam > 220°F Loss of Flow VIII.C-5 3.4.1-29 A

boundary steel (int) material accelerated (S-15) corrosion Orifice Pressure Carbon Steam > 220'f Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Orifice Pressure Carbon Steam > 220*f Loss of Water VIII.C-3 3.4.1-2 A

boundary steel (int) material Chemistry (S-04)

Control - BWR Orifice Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel

> 220'F (int) fatigue fatigue 5

(S-08)

Orifice Pressure Carbon Treated water Loss of Water VIII.C-6 3.4.1-4 A

boundary steel (int) material Chemistry (S-09)

Control - BWR Piping Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Piping Pressure Carbon Steam > 220'F Loss of Flow VIII.C-5 3.4.1-29 A

boundary steel (int) material accelerated (S-15) corrosion Piping Pressure Carbon Steam > 220'F Loss of Water VIII.C-3 3.4.1-2 A

boundary steel (int) material Chemistry (S-04)

I

_Control

- BWR Piping Pressure Carbon Steam > 220'F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Page 41 of 63 BVY 07-054 Docket 50-271

[Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 42 1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Piping Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Treated water Loss of Water VIII.C-6 3.4.1-4 A

boundary steel (int) material Chemistry (S-09)

Control - BWR Tubing Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Tubing Pressure Carbon Treated water Loss of Water VIII.C-6 3.4.1-4 A

boundary steel (int) material Chemistry (S-09)

Control - BWR Valve Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

body boundary steel (ext) material Walkdown (S-29)

Valve Pressure Carbon Steam > 220'F Loss of Flow VIII.C-5 3.4.1-29 A

body boundary steel (int) material accelerated (S-15) corrosion Valve Pressure Carbon Steam > 220°F Loss of Water VIII.C-3 3.4.1-2 A

body boundary steel (int) material Chemistry (S-04)

Control - BWR Valve Pressure Carbon Steam > 220°F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

body boundary steel (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Treated water Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

body boundary steel

> 220°F (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Treated water Loss of Water VIII.C-6 3.4.1-4 A

body boundary steel (int) material Chemistry (S-09)

Control - BWR LRA Section 3.3.2, Table 3.3.2-13-13, Feedwater (FDW) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Heat Pressure Carbon Air - indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Steam > 220*F Cracking -

One-Time H

exchanger boundary steel (int) fatigue Inspection (shell)

I Heat Pressure Carbon Steam > 220'F Loss of Water VII.E3-3.3.1-17 C

exchanger, boundary steel (int) material Chemistry 18 (shell)

Control - BWR (A-35)

Heat Pressure Carbon Treated water Cracking -

One-Time H

exchanger boundary steel

> 220°F (int) fatigue Inspection (shell)

Heat Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

exchanger boundary steel

> 220°F (int) material Chemistry 18 (shell)

Control - BWR (A-35)

Orifice Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Orifice Pressure Carbon Treated water Cracking -

TLAA - metal VIII.D2-3.4.1-1 A

boundary steel

> 220°F (int) fatigue fatigue 6

(S-11)

Page 42 of 63 BVY 07-054 Docket 50-271

1: Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_:jidoc Page 43 1 Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 43 I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Orifice Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel

> 220'F (int) material Chemistry 7

Control - BWR (S-09)

Piping Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary steel material (AP-30)

Piping Pressure Carbon Steam > 220'F Loss of Flow VIII.C-5 3.4.1-29 A

boundary steel (int) material accelerated.

(S-15) corrosion Piping Pressure Carbon Steam > 220'F Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(s-08)

Piping Pressure Carbon Steam > 2207F Loss of Water VIII.C-3 3.4.1-2 A

boundary steel (int) material Chemistry (S-04)

Control - BWR Pump Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

casing boundary steel (ext) material Walkdown (S-29)

Pump Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

casing boundary steel material (AP-30)

Pump Pressure Carbon Treated water Cracking -

One-time H

casing boundary steel

> 220°f (int) fatigue inspection Pump Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

casing boundary steel

> 220'f (int) material Chemistry 7

Control - BWR (S-09)

Strainer Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Treated water Cracking -

One-time H

housing boundary steel

> 220°f (int) fatigue inspection Strainer Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

housing boundary steel

> 220°f (int) material Chemistry 7

Control - BWR (S-09)

Tubing Pressure Copper Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary alloy <

material (AP-30) 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.E3-3.3.1-17 C

boundary alloy <

> 220'f (int) material Chemistry 18 15% Zn Control - BWR (A-35)

Tubing Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 A

boundary steel (ext)

(AP-1 7)

Tubing Pressure Stainless Lube oil (int)

Loss of.

Oil analysis VII.C1-8 3.3.1-26 E

boundary steel material (AP-47)

Tubing Pressure Stainless Treated water Cracking -

TLAA - metal H

boundary steel

> 270°f (int) fatigue fatigue Tubing Pressure Stainless Treated water Loss of Water VIII.D2-3.4.1-16 A

boundary steel

> 270'f (int) material chemistry 4

control - BWR (SP-16)

Tubing Pressure Stainless Treated water Cracking Water VIll.A-3.4.1-13 C

boundary steel

> 270°f (int)

Chemistry 11 Control - BWR (SP-45)

Valve Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.C1-3.3.1-14 E

body boundary steel material 17 (AP-30)

Valve Pressure Carbon Steam > 220°F Loss of Flow VIII.C-5 3.4.1-29 A

body boundary steel (int) material accelerated (S-15) corrosion Valve Pressure Carbon Steam > 220°F Cracking -

TLAA - metal VIII.B2-3.4.1-1 A

body boundary steel (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Steam > 220°F Loss of Water VIII.C-3 3.4.1-2 A

body boundary steel (int) material Chemistry (S-04)

Control - BWR Page 43 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - 13' VY'07-054 Att 2 -'54.4(a)(2) Scoping-2.d.oc Jonathan Rowley - BVYO7-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 44~

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2, Table 3.3.2-13-14, Fuel Oil (FO) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation,. is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Strainer Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Fuel oil (int)

Loss of Diesel fuel VII.H1-3.3.1-20 E

housing boundary steel material monitoring 10 (A-30)

Strainer Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 A

housing boundary steel (ext)

(AP-17)

Strainer Pressure Stainless Fuel oil (int)

Loss of Diesel fuel VII.H1-6 3.3.1-32 E

housing boundary steel material monitoring (AP-54) I Page 44 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-064ýAft2'_ 64.'4_(ýý)ý2')' Sco - ' - - _'

, 19 Paqe..4ý]

Jonathan Rowley - BVY 07-O54Att 2 - 54.4(a)(2) Scoping2.doc Page 45 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-15, Fire Protection (FP) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Orifice Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Orifice Pressure Carbon Raw water (int)

Loss of Fire water VII.G-24 3.3.1-68 B

boundary steel material system (A-33)

Strainer Pressure Carbon Air - indoor Loss of System VI1I.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Raw water (int)

Loss of Fire Water VII.G-24 3.3.1-68 B

housing boundary steel material System (A-33)

Strainer Pressure Gray cast Air - indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary iron (ext) material Walkdown (A-77)

Strainer Pressure Gray cast Raw water (int)

Loss of Fire Water VII.G-24 3.3.1-68 B

housing boundary iron material System (A-33)

Strainer Pressure Gray cast Raw water (int)

Loss of Selective VIL.G-14 3.3.1-85 A

housing boundary iron material leaching (A-51)

Page 45 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2-54.4(a)(2) Scoping_2.doc Page 46 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2, Table 3.3.2-13-18, House Heating Boiler (HB) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Heat Pressure Carbon Air-indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Condensation Loss of System VI.L1-11 3.3.1-58 A

exchanger boundary steel (ext) material walkdown (A-81)

(shell)

Heat Pressure Carbon Steam> 220° F Loss of Water VII.C2-3.3.1-47 E, 305 exchanger boundary steel (int) material chemistry 14 (shell) control -

(A-25) auxiliary systems Heat Pressure Carbon Steam> 220° F Cracking -

One-time H

exchanger boundary steel (int) fatigue inspection (shell)

Heat Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E, 305 exchanger boundary steel (int) material chemistry 14 (shell) control -

(A-25) auxiliary systems Strainer Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Condensation Loss of System VII.1-11 3.3.1-58 A

housing boundary steel (ext) material walkdown (A-81)

Strainer Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E, 305 housing boundary steel (int) material chemistry 14 control -

(A-25) auxiliary systems Page 46 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc f~g9 ~

Jonathan Rowley - BVY 07-0.54 Att 2 - 5.4.4(a)(2.) Scopi.ng-2.doc

_P.age 47'.l VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-49, Heater Drain (HD)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VIII.H-4 3.4.1-22 E

boundary steel (ext) material Walkdown (S-34)

Bolting Pressure Stainless Air-indoor None None VIII1.-10 3.4.1-41 C

boundary steel (ext)

(SP-1 2)

Piping Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Piping Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Pump Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

casing boundary steel (ext) material Walkdown (S-29)

Pump Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

casing boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Tank Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Tank Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Tubing Pressure Copper Air-indoor None None VIII.1-2 3.4.1-41 A

boundary alloy (ext)

(SP-6)

  • 15% Zn Tubing Pressure Copper Treated water Loss of Water VIII.A-5 3.4.1-15 C

boundary alloy (int) material Chemistry (SP-61)

< 15% Zn Control - BWR Valve Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

body boundary steel (ext) material Walkdown (S-29)

Valve Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

body boundary steel (int) material Chemistry 7

I_

I_

Control - BWR (S-09)

Page 47 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 01-054 Att 2 - 54.4(a)(2) Sco.pi.ng..2..

d.oc Page 48 :1 Jona.. han.Rowley....07-054.Att.2.

54

.4(a)(2).......................

d ag 8 I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-50, Heater Vents (HV)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VIII.H-4 3.4.1-22 E

boundary steel (ext) material Walkdown (S-34)

Bolting Pressure Stainless Air - indoor None None VIII.I-10 3.4.1-41 C

boundary steel (ext)

(SP-1 2)

Orifice Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Orifice Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Piping Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Piping Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Tank Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Tank Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Tubing Pressure Copper Air-indoor None None VIII.l-2 3.4.1-41 A

boundary alloy (ext)

(SP-6)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VIIlA-5 3.4.1-15 C

boundary alloy (int) material Chemistry (SP-61)

< 15% Zn Control - BWR Valve Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

body boundary steel (ext) material Walkdown (S-29)

Valve Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 A

body boundary steel (int) material Chemistry 7

1_

1_

1_

1 Control - BWR (S-09)

Page 48 of 63 BVY 07-054 Docket 50-271

1; Jonathan Rowley - BVY 07-064 Att 2 - 64.4(a)(2) Scoping_2.doc Page 49 1

[Jonath..

n. R..wley...BVY..07-054.Att..2......4a(

)S o

ng......

Page.............49....

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-21, Heating, Ventilation, and Air Conditioning (HVAC)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Duct Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Duct Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (int) material Walkdown (A-77)

Fan Pressure Carbon Air-indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Fan Pressure Carbon Air-indoor Loss of System V11.1-8 3.3.1-58 A

housing boundary steel (int) material Walkdown (A-77)

Heat Pressure Carbon Condensation Loss of System V11.1-1 1 3.3.1-58 A

exchanger boundary steel (ext) material Walkdown (A-81)

(shell)

Heat Pressure Carbon Raw water (int)

Loss of Service water VILCI-3.3.1-76 D

exchanger boundary steel material integrity 19 (shell)

(A-38)

Pump Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Raw water (int)

Loss of Service water VII.C1-3.3.1-76 D

casing boundary steel material integrity 19 (A-38)

Strainer Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Strainer Pressure Carbon Raw water (int)

Loss of Service water VII.C1-3.3.1-76 D

housing boundary steel material integrity 19 1_

(A-38)

Page 49 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 01-064 Att 2 - 54.4(a)(2) Scoping_2.doc P ag e 50 Jonathan.....Rowley....

BVY..07-054..

A..t.2........4a 2)S o

ng.d.......

Page............50.....

.I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-51, Hydrogen Water Chemistry (HWC) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.1-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Piping Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tubing Pressure Copper Air-indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-10)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Valve Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

body boundary steel (ext)'

material Walkdown (A-77)

Valve Pressure Carbon Treated water Loss of Water VIIIE-3.4.1-4 A

body boundary steel (iht) material Chemistry 33 Control - BWR (S-09)

LRA Section 3.3.2, Table 3.3.2-13-22, Instrument Air (IA) System, Nonsafety-Relafed Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised to delete the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item S....e.....

Pressure-Garbon-A-O,-

Loss-of-ysytem-VI--3 3.3.

A heusig b

steel 4

material W

dew-(A,...

ess..

PFessUfe-GarbeR T....4ed...

L-es-of-Water V!LG2-3..47 hOusiOg boundary steel 040) material

.hemisty. 1-4 Go.4tFG-(-2ý Closed-Pipli PreSSUre-Garbon-Lube-eil-(iRit)

Loss-of-Gil-Analysis Vii.C-1 3.3.1144E boundary steel material 4-PiRq Pressure-Carbon T-reated watr-t Less-of-Water-

VAl, 33.1 17 G

boundary steel (in) material ChemCtrc y

4R Cenitrl--BW (A-3_

Page 50 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 0-7-0-54 Att 2 -54.4'(a)(2') Scoping 2.doc Pag 1..

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-52, Main Steam (MS) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VIII.H-4 3.4.1-22 E

boundary steel (ext) material Walkdown (S-34)

Bolting Pressure Stainless Air - indoor None None VIII.I-10 3.4.1-41 C

boundary steel (ext)

(SP-1 2)

Heat Pressure Carbon Air - indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Steam > 270'F Cracking -

One-Time H

exchanger boundary steel (int) fatigue Inspection (shell)

I Heat Pressure Carbon Steam > 270'F Loss of Water VII.E3-3.3.1-17 C

exchanger boundary steel (int) material Chemistry 18 (shell)

Control - BWR (A-35)

Orifice Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Orifice Pressure Carbon Steam > 2701f Cracking -

TLAA - metal VIII.B2-3.4.1-1 A

boundary steel (int) fatigue fatigue 5

(S-08)

Orifice Pressure Carbon Steam > 270"f Loss of Flow VIII.B2-3.4.1-29 A

boundary steel (int) material accelerated 4

corrosion (S-15)

Orifice Pressure.

Carbon Steam > 270'f Loss of Water VIII.B2-3.4.1-37 A

boundary steel (int) material Chemistry 3

Control - BWR (S-05)

Piping Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Piping Pressure Carbon Steam > 270°f Cracking -

TLAA - metal VIII.B2-3.4.1-1 A

boundary steel (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Steam > 270°f Loss of Flow VIII.B2-3.4.1-29 A

boundary steel (int) material accelerated 4

corrosion (S-15)

Piping Pressure Carbon Steam > 270*F Loss of

- Water VIII.B2-3.4.1-37 A

boundary steel (int) material Chemistry 3

Control - BWR (S-05)

Piping Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 C

boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Strainer Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 C

housing boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-10)

< 15% Zn Tubing Pressure Copper Steam > 270'F Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Page 51 of 63 BVY 07-054 Docket 50-271

Jon tha.R w.e..BVY 07.54 At.2.

.5.4a

( ) S o i g...

Pag....

.52 I Jonýthaýn fýovvley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping.2.doc VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Tubing Pressure Stainless Air-indoor None None VIII.I-10 3.4.1-41 A

boundary steel (ext)

(SP-12)

Tubing Pressure Stainless Steam > 270°F Cracking -

TLAA - metal H

boundary steel (int) fatigue fatigue Tubing Pressure Stainless Steam > 270'F Loss of Water VIII.B2-3.4.1-37 A

boundary steel (int) material chemistry 2

control - BWR (SP-46)

Tubing Pressure Stainless Steam > 270"f Cracking Water VIII.B2-3.4.1-13 A

boundary steel (int)

Chemistry 1

Control - BWR (SP-45)

Valve Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

body boundary steel (ext) material Walkdown (S-29)

Valve Pressure Carbon Steam > 270°F Cracking -

TLAA - metal VIII.B2-3.4.1-1 A

body boundary steel (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Steam > 270=F Loss of Flow VIII.B2-3.4.1-29 A

body boundary steel (int) material accelerated 4

corrosion (S-15)

Valve Pressure Carbon Steam > 270°F Loss of Water VIII.B2-3.4.1-37 A

body boundary steel (int) material Chemistry 3

Control - BWR (S-05)

Valve Pressure Carbon Treated water Loss of Water VIII.D2-3.4.1-4 C

body boundary steel (int) material Chemistry 7

Control - BWR (S-09)

Page 52 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - B 01-054 Aft 2 - 64.4(a)(2) Scopingj.doc Pa'ge 53.1 Jonathan.

B..

7-4 A. 2....

......S......

d.

P e

.i VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-53, Make-up Demineralizer (MUD) System, Nonsafety-Related Components Affecting Safety-Related Systems -

Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-i7)

Filter Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

housing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Piping Pressure Carbon Air - indoor Loss of System VII.l-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Pump Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

casing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tank Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy <

(ext)

(EP-10) 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy <

(int) material Chemistry AP-64) 15% Zn Control-BWR Valve Pressure Carbon Air-indoor Loss of System VII.1-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

body boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Page 53 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 54]

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-29, Potable Water (PW) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Filter Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Untreated Loss of Periodic VII.G-24 3.3.1-68 E

housing boundary steel water (int) material Surveillance (A-33) and Preventive I

Maintenance Strainer Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Strainer Pressure Carbon Untreated Loss of Periodic VIL.G-24 3.3.1-68 E

housing boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Tank Pressure Carbon Air - indoor Loss of System VIl.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Untreated Loss of Periodic VIL.G-24 3.3.1-68 E

boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Valve Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Untreated Loss of Periodic VIL.G-24 3.3.1-68 E

body boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Page 54 of 63 BVY 07-054 Docket 50-271

[Jonathan Rowley-BVY- 07-054 Att 2 - 54.4(a)(2) Scoping-2.docP PRagle..55.1!

VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-54, Service Air (SA) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VIi.l-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-1 7)

Piping Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Air-indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (int) material Walkdown (A-77)

Tank Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Untreated Loss of Periodic VII.G-24 3.3.1-68 E

boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Trap Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Trap Pressure Carbon Untreated Loss of Periodic VII.G-24 3.3.1-68 E

boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance Valve Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

body boundary steel (int) material Walkdown (A-77)

Valve Pressure Carbon Untreated Loss of Periodic VII.G-24 3.3.1-68 E

body boundary steel water (int) material Surveillance (A-33) and Preventive Maintenance I

Page 55 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BV..Y 0(7-05a 4A 2-5..4.(.)(2) s.coping-2.doc P.

5age56 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-39, Stator Cooling (SC) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.1-4

-3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-1 7)

Filter Pressure Carbon Air - indoor Loss of System V11.l-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E

housing boundary steel (int) material Chemistry 14 Control -

(A-25)

Auxiliary Systems Heat Pressure Carbon Air - indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E

exchanger boundary steel (int) material Chemistry 14 (shell)

Control -

(A-25)

Auxiliary Systems Pump Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E

casing boundary steel (int) material Chemistry 14 Control -

(A-25)

Auxiliary Systems Strainer Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Strainer Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E

housing boundary steel (int) material Chemistry 14 Control -

(A-25)

Auxiliary Systems Tank Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 E

boundary steel (int) material Chemistry 14 Control -

(A-25)

Auxiliary Systems Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-1 0)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.C2-3.3.1-47 E

boundary alloy (int) material Chemistry 14

< 15% Zn Control -

(A-25)

Auxiliary L

_Systems Page 56 of 63 BVY 07-054 Docket 50-271

I: Jonatan.Ro.ey..BVY...0....t....5.4( )2 S o g.......

Page...

57..

Jonathan Rowley - BVY 07-054 Att 2 - 54A(a)(2) Scoping_2.doc

.Page5.57.1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-55, Seal Oil (SO) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.l-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Filter Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

housing boundary steel material (AP-30)

Piping Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary steel material (AP-30)

Pump Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

casing boundary steel material (AP-30)

Sight Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

glass boundary steel (ext) material Walkdown (A-77)

Sight Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

glass boundary steel material (AP-30)

Sight Pressure Glass Air - indoor None None VII.J-8 3.3.1-93 A

glass boundary (ext)

(AP-1 4)

Sight Pressure Glass Lube oil (int)

None None VII.J-10 3.3.1-93 A

glass boundary (AP-1 5)

Tank Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary steel material (AP-30)

Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-IO)

< 15% Zn Tubing Pressure Copper Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary alloy <

material (AP-30) 15% Zn Valve Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

body boundary steel material (AP-30)

Page 57 of 63 BVY 07-054 Docket 50-271

Jionpt4n kowleyl 8\\/Y-b?-'064 Att 2'_ 64.4(a)'(2)'Scoping 2.doc II Page 58 1

[Jonathar~Rowley - BVYO7:054 Att 254.4(a)(2) Scoping2.doc Page 58 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2, Table 3.3.2-13-41, Sampling (SPL) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol,2 Item Strainer Pressure Carbon Air - indoor Loss of System VIIIH-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

housing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

Strainer Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 A

housing boundary steel (ext)

(AP-17)

Strainer Pressure Stainless Treated water Loss of Water VIII.E-3.4.1-4 A

housing boundary steel (int) material Chemistry 33 Control - BWR (S-09)

LRA Section 3.3.2, Table 3.3.2-13-42, Service Water (SW) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, is revised adding the following line items.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Heat Pressure Carbon Air - indoor Loss of System VIF1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Condensation Loss of System V11.1-11 3.3.1-58 A

exchanger boundary steel (ext) material walkdown (A-81)

(shell)

I Heat Pressure Carbon Raw water (int)

Loss of Service water VII.C1-5 3.3.1-77 B

exchanger boundary steel material integrity (A-64)

(shell)

Heat Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 A

exchanger boundary steel (ext)

(AP-1 7)

(shell)

Heat Pressure Stainless Condensation Loss of System VII.F1-1 3.3.1-27 E

exchanger boundary steel (ext) material walkdown (A-09)

(shell)

Heat Pressure Stainless Raw water (int)

Loss of Service water VII.C1-3.3.1-79 D

exchanger boundary steel material integrity 15 (shell)

(A-54)

Pump Pressure Carbon Condensation Loss of System VI1.1-11 3.3.1-58 A

casing boundary steel (ext) material walkdown (A-81)

Pump Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 A

casing boundary steel (ext)

(AP-17)

Pump Pressure Stainless Condensation Loss of System VII.F1-1 3.3.1-27 E

casing boundary steel (ext) material walkdown (A-09)

Pump Pressure Stainless Raw water (int)

Loss of Service water VII.C1-3.3.1-79 D

casing boundary steel material integrity 15 (A-54)

Page 58 of 63 BVY 07-054 Docket 50-271

1: Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 591 I,

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping2.doc Page 59 I VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-56, Turbine Building Closed Cooling Water (TBCCW) System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Componenl Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol,2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Heat Pressure Carbon Air-indoor Loss of System VII.F1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 B

exchanger boundary steel (int) material Chemistry 14 (shell)

Control -

(A-25)

Closed Cooling Water Piping Pressure Carbon Air-indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 B

boundary steel (int) material Chemistry 14 Control -

(A-25)

Closed Cooling Water Pump Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 B

casing boundary steel (int) material Chemistry 14 Control -

(A-25)

Closed Cooling Water Tank Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Tank Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 B

boundary steel (int) material Chemistry 14 Control -

(A-25)

Closed Cooling Water Tubing Pressure Copper Air-indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-1 0)

< 15% Zn Tubing Pressure Copper Treated water Loss of Water VII.C2-3.3.1-47 B

boundary alloy (int) material Chemistry 14

< 15% Zn Control -

(A-25)

Closed Cooling Water Valve Pressure Carbon Air-indoor Loss of System VII.1-8 3.3.1-58 A

body boundary steel (ext) material Walkdown (A-77)

Valve Pressure Carbon Treated water Loss of Water VII.C2-3.3.1-47 B

body boundary steel (int) material Chemistry 14 Control -

(A-25)

Closed I ___

_ I__I__I__I__

ICooling Water I I

I Page 59 of 63 BVY 07-054 Docket 50-271

Jon tha.R.

.ey..

BY.0

-05.At.2.

.5 ng.........

Page....

60

[ Joqathan Rowley - 13VY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 60 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-57, Main Turbine Generator (TG) System, Nonsafety-Related Components Affecting Safety-Related Systems -

Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.I-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-1 7)

Filter Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Steam > 270'f Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

housing boundary steel (int) fatigue fatigue 5

(S-08)

Filter Pressure Carbon Steam > 270'f Loss of Water Vill.A-3.4.1-2 C

housing boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Piping Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Steam > 270°f Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

boundary steel (int) fatigue fatigue 5

(S-08)

Piping Pressure Carbon Steam > 270'f Loss of Flow VIll.A-3.4.1-29 C

boundary steel (int) material Accelerated 17 I

Corrosion (S-15)

Piping Pressure Carbon Steam > 270'f Loss of Water VIll.A-3.4.1-2 C

boundary steel (int) material Chemistry 15 Control - BWR (S-04)

Pump Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Treated water Cracking -

One-time H

casing boundary steel

> 270Of (int) fatigue inspection Pump Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

casing boundary steel

> 270°f (int) material Chemistry 18 Control - BWR (A-35)

Turbine Pressure Carbon Air - indoor Loss of System VII.I-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Turbine Pressure Carbon Steam > 270°f Cracking -

One-time H

casing boundary steel (int) fatigue inspection Turbine Pressure Carbon Steam > 270°f Loss of Water VII.E3-3.3.1-17 C

casing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Turbine Pressure Carbon Treated water Loss of Water VII.E3-3.3.1-17 C

casing boundary steel (int) material Chemistry 18 Control - BWR (A-35)

Tubing Pressure Copper Air-indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-1 0)

< 15% Zn Tubing Pressure Copper Steam > 270'f Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Tubing Pressure Copper Treated water Loss of Water VII.E3-9 3.3.1-31 C

boundary alloy (int) material Chemistry (AP-64)

< 15% Zn Control - BWR Valve Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

body' boundary steel (ext) material Walkdown (A-77)

Page 60 of 63 BVY 07-054 Docket 50-271

Jon.han R

.wey..BVY 07-54..

t.

.5.......

Page...61.

Jonathan Rowley - BVY 07-054 Att 2 - 54.4(a)(2) Scoping_2.doc Page 61 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 Valve Pressure Carbon Steam > 270'f Cracking -

TLAA - metal VIII.B2-3.4.1-1 C

body boundary steel (int) fatigue fatigue 5

(S-08)

Valve Pressure Carbon Steam > 270'f Loss of Flow VIll.A-3.4.1-29 C

body boundary steel (int) material accelerated 17 corrosion (S-15)

Valve Pressure Carbon Steam > 270'f Loss of Water VIll.A-3.4.1-2 C

body boundary steel (int) material Chemistry 15 1

1 1

A 1 Control - BWR (S-04)

Valve Pressure Carbon Treated water Loss of Water VIII.E-3.4.1-4 A

body boundary steel (int) material Chemistry 33 I Control - BWR (S-09)

Page 61 of 63 BVY 07-054 Docket 50-271

Jonathan Rowley - BVY 0 7-054 Att 2 - 54. 4(a)(2 S.coping

.doc Pagc6

.I

....P a g e 6 2 ]1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2

> LRA Section 3.3.2 is revised to add a new Table 3.3.2-13-58, Turbine Lube Oil (TLO)

System, Nonsafety-Related Components Affecting Safety-Related Systems - Summary of Aging Management Evaluation, as follows.

Component Intended Material Environment Aging Effect Aging NUREG-Table 1 Notes Type Function Requiring Management

1801, Item Management Programs Vol.2 Item Bolting Pressure Carbon Air - indoor Loss of System VII.l-4 3.3.1-43 E

boundary steel (ext) material Walkdown (AP-27)

Bolting Pressure Stainless Air-indoor None None VII.J-15 3.3.1-94 C

boundary steel (ext)

(AP-17)

Filter Pressure Carbon Air-indoor Loss of System VII.1-8 3.3.1-58 A

housing boundary steel (ext) material Walkdown (A-77)

Filter Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

housing boundary steel material (AP-30)

Heat Pressure Carbon Air - indoor Loss of System VIIF1-3.3.1-59 C

exchanger boundary steel (ext) material Walkdown 10 (shell)

(AP-41)

Heat Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

exchanger boundary steel material (AP-30)

(shell)

Piping Pressure Carbon Air - indoor Loss of System VII.t-8 3.3.1-58 A

boundary steel (ext) material Walkdown (A-77)

Piping Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary steel material (AP-30)

Pump Pressure Carbon Air - indoor Loss of System VII.1-8 3.3.1-58 A

casing boundary steel (ext) material Walkdown (A-77)

Pump Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

casing boundary steel material (AP-30)

Strainer Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

housing boundary steel (ext) material Walkdown (S-29)

Strainer Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

housing boundary steel material (AP-30)

Tank Pressure Carbon Air-indoor Loss of System VIII.H-7 3.4.1-28 A

boundary steel (ext) material Walkdown (S-29)

Tank Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary steel material (AP-30)

Tubing Pressure Copper Air - indoor None None V.F-3 3.2.1-53 C

boundary alloy (ext)

(EP-10)

< 15% Zn Tubing Pressure Copper Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

boundary alloy <

material (AP-30) 15% Zn Valve Pressure Carbon Air - indoor Loss of System VIII.H-7 3.4.1-28 A

body boundary steel (ext) material Walkdown (S-29)

I Valve Pressure Carbon Lube oil (int)

Loss of Oil analysis VII.G-22 3.3.1-14 E

body boundary steel material (AP-30)

Page 62 of 63 BVY 07-054 Docket 50-271

I Jonathan Rowley - BVY 07-054 Att 2-54.4(a)(2) Scoping,2.doc Page,63.1 VERMONT YANKEE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION SUPPLEMENT ATTACHMENT 2 LRA Section B.1.21 is revised to add the following systems to the list of nonsafety-related systems affecting safety-related components managed by the One-Time Inspection Program.

o Auxiliary Steam (AS) o Condensate (C) o Feedwater (FDW) o House Heating Boiler (HB) o Main Steam (MS) o Main Turbine Generator (TG)

LRA Section B.1.22 is revised to add the following systems to the list of nonsafety-related systems affecting safety-related components managed by the Periodic Surveillance and Preventive Maintenance Program.

O Buildings (drainage system components) (BLD)

Circulating Water Priming (CWP) o Service Air (SA)

Page 63 of 63 BVY 07-054 Docket 50-271