19 Final Status Survey Final Report Phase VII Appendix A14 Survey Unit Release Record 9514-0000, West Primary Parking Lot May 2007

CYAPCO FINAL STATUS SURVEY RELEASE RECORD WEST PRIMARY PARKING LOT SURVEY UNIT 9514-0000

_Date:

Prepared By:

FSS Engineer ReiwdZ-)WO

,Al-

~FSS ngineer.

Approved B Technical Support Manager Date: 42 0

Date:

Revision 0

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION...........................................

3

2.

CLASSIFICATION BASIS.................................................

3

3.

DATA QUALITY OBJECTIVES (DQO).................................

6

4.

SURVEY DESIGN...........................................................

9

5.

SURVEY IMPLEMENTATION..........................................

13

6.

SURVEY RESULTS.......................................................

14

7.

QUALITY CONTROL.....................................................

18

8.

INVESTIGATIONS AND RESULTS....................................

19

9.

REMEDIATION AND RESULTS........................................

20

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN.......... 20
11. DATA QUALITY ASSESSMENT (DQA)...............................

20

12. ANOMALIES...............................................................

21

13. CONCLUSION.............................................................

22

14. ATTACHMENTS...........................................................

23 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (6 pages including cover) 14.3 Attachment 3 - Laboratory Results (120 pages including cover) 14.4 Attachment 4 - DQA Results (18 pages including covers)

TOTAL 173 Revision 0

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9514-0000 (West Primary Parking Lot) is designated as a Final Status Survey (FSS) Class 3 survey unit and consists of eighteen thousand seven hundred fifty-seven square meters (18,757 in') or 4.635 acres of uninhabited open land located approximately five hundred and sixty-five feet (565 ft) south of the reference coordinate system benchmark used at Haddam Neck Plant (HNP).

This survey unit is bounded by Survey Units 9506-0000 and 9508-0000 to the north (called north based on the general north to south flow of the Connecticut River), Survey Unit 9514-0001 to the east, Survey Units 9302-0000 and 9313-0000 to the south and by Survey Unit 9512-0000 to the west.

The survey unit is located outside of the former Radiological Controlled Area (RCA), outside the former Industrial Area but within the Owner Controlled Area.

The survey unit is comprised of predominantly flat disturbed open land that gently slopes from east to west toward the Connecticut River.

The reference coordinates associated with this survey unit are E004 through E010 by S050 through S058 (refer to LTP Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.

The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classifiation. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9514-0000 as Class 3 in February 2007.

The "Classifcation Basis Summary" conducted for Survey Unit 9514-0000 consisted of:

a) A review of the 10CFR5O.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walk-down." of the area were performed.

Survey Area 9514, which consists of the Primary Parking Lot, is a surface survey area (the corresponding sub-surface Survey Area is 9803) that has historically been used to stockpile soils, asphalt spoils, snow and other materials.

Containerized radioactive materials have also been stored here over the past few Revision 0 3

Revision 0 3

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD years. The historical assessment of the survey area indicated that the age of the paved area dates back to the earliest days of plant operation. The scoping report in 1997 had little information on this area, but did note that Plant Incident Report (PIR) 80-37 reported the discovery of several sources of elevated activity in March 1980, along with other areas of the site. The investigation into the incident concluded that the elevated activity was most likely due to radioactive materials ejected from the Primary Vent Stack as a result of operational events in 1979. Isotopic analysis of the particles indicated that the short-lived fission products, Ce-144 and Ru-106, dominated the particulate radioactivity. All elevated areas were removed upon detection according to supplemental reports.

A review of the 10 CFR 50.75(g) files identified five (5) additional entries identifying Survey Area 9514 (Survey dated 6/11/79; Contract, drawings and Spec. work logs from 10/11/82; Email from GTS Duratek dated 1/26/99; memo HP-99-1 11; memo HP-99-1 13); however, these sources did not provide a significant amount of additional information for characterization of Survey Area 9514. Additionally, Warehouse #2 and the Office Building #3/PAP were constructed in 1989 and the primary parking lot was re-configured. The primary parking lot was enlarged, re-paved and storm drains installed. Scanning of the parking lot was conducted on September 17-25, 1997 using a floor monitor. No elevated areas of activity were identified. Soil samples were taken of a proposed sanitary sewer sump location just west of the Security Building Primary Access Point (PAP). No plant related radioactivity was identified in these samples.

Areas behind the Building Maintenance Equipment Warehouse and the Chemical Storage Warehouse were also used as storage areas for radioactive materials returned to site as a result of the Offsite Materials Recovery Program.

A storm drain system was installed under the parking area. The storm drain system's purpose was to conduct runoff water from the parking lot, including the northern-most side of Survey Area 9313 (adjacent to the office building and warehouses), and the west hillside primarily to the retention pond. Outfalls from the storm drain system discharge to the southeast and southwest banks of the pond (Survey Area 9508). Overflow from the retention pond discharges to the west bank of the Connecticut River (Survey Area 9512).

Recent decommissioning activities included the removal of asphalt, concrete and sub-surface commodities such as storm drain and sewer system piping.

Two (2) potential pathways for residual contamination to exist within this survey area are from the mixing of surface soils with paving materials during demolition or from storm drain pipe leakage.

After remediation was complete in Survey Area 9514, characterization samples were collected and analyzed in accordance with Survey and Sampling Work Plan (SSWP) 06-09-001. Evaluation of soil samples collected for the SSWP provided the information with regard to the radionuclides of concern within Survey Area 9514. These results are summarized in Table 1.

Revision 0 4

Revision 0 4

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ITable 1-Basic statistical anantities from SSWP 06-09-001 Radiologi4cal Assessment survey Parameter Cs-137 Co-60 Sr-90 (Pcilg)

(Pci/g) 00~/0)

Operational DCCL:

5.38E+00 2.59E+/-00 1.05E+/-00 Minimum Value:

-9.6 8E-03

-3.21 E-02 5.67E-03 Maximum Value:

8.44E-01I 9.36E-02 7.39E-02 Mean:

9.22E-02 4.87E-03 3.43E-02 Median:

3.06E-02 3.16E-03 2.95E-02 Standard Deviation:

2.06E-0 1 2.64E-02 2.18E-02 Characterization sample data indicated that several locations in the eastern portion of Survey Area 9514 contained elevated amounts of Sr-90 at levels up to seven percent (7%) of the Operational Derived Concentration Guideline Level (DCGL) for Sr-90.

Toward the end of 2006, a small section of Survey Unit 95 06-0000 was disturbed by grading operations. Rather than performing the FSS on Survey Unit 9506-0000 a small area to the south of the retention pond was added to Survey Area 9514 and FSS was performed on the newly formed survey area.

Based on the characterization results provided in Table 1, Survey Area 9514 was split into two (2) survey units. Survey Unit 9514-0001 is a Class 2 survey unit which consists of open land and comprises the eastern portion of the former primary parking lot. The western portion of the former primary parking lot is covered by Survey Unit 9514-0000, a Class 3 survey unit (the survey unit covered by this Release Record).

The characterization results for Survey Unit 95 14-0000 indicate that Cs-137 and Co-60 are the radionuclides of concern for this survey unit. HTD radionuclide analysis indicated that Sr-90 was positively identified (a result greater than two (2) standard deviations error) in five (5) samples in the eastern portion of Survey Area 9514, which later became Survey Unit 9514-0001, a Class 2 survey unit. Therefore, Sr-90 was also selected as a radionuclide of concern.

Only one (1) other HTD radionuclide, Curium-243/244 (Cm-243/244), was identified but was de-selected as a potential radionuclide of concern because it was not present at a concentration above 5% of the Operational DCCL for soil individually or 10% of the Operational DCCL for soil as a composite.

The FSS Engineer performed a visual inspection and walk-down during February 2007 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Revision 0 5

Revision 0 5

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 3 (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5. 1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the Final Status Survey Plan (FSSP). Probabilistic sampling is a preferred method to select a sample so that each item in the population being studied has a known likelihood of being included in the sample. Probabilistic sampling may include simple random sampling where every sample has the same chance of being included, or systematic random sampling where samples are arranged in some order and a random starting point is selected.

The primary objective of the FSSP was to demonstrate that the level of residual radioactivity in Survey Unit 9514-0000 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCCL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

Revision 0 6

Revision 0 6

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1 H Total=Hsoii +HExistingGw +H FutureG W The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mremlyr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024).

Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mremlyr TEDE.

Equation 2 19 mremlyrTotal = 17 mrem/yrs,01 l +/- 2 mremlyrExisting Gw+ 0 mrenllyrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Revision 0 7

Revision 0 7

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Table 2 - Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1)

Base Case Soil Operational DCGL Required MDC DCGL (pCi/g) (2)

(pC i/g) (3)

(pCi/g) (4)

H-3 4.12E+02 2.8 1E+/-02 1.65E+01 C-14 5.66E+00 3.84E+00 2.26E-01 Mn-54

1. 74E+/-0 1
1. 18E+01I 6.96E-01I Fe-55 2.74E+04
1. 87E+04 1.10OE+/-03 Co-60 3.81E+/-00 2.59E+/-00 1.52E-01 Ni-63 7.23E+02 4.9 1E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.85E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-0OI Ag-i 08m
7. 14E+00 4.86E+00 2.86E-0 1 Cs-134 4.67E+00 3.1 8E+00 1.87E-0 1 Cs-137 7.9 1E+00 5.38E+00 3.16E-01 Eu-152 1.O1E+01 6.87E+00 4.04E-01I Eu-154 9.29E+00 6.32E+00 3.72E-0 I Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01I 2.01E+01
1. 18E+00 Pu-239/240 2.67E+0 1
1. 82E+0 1 1.07E+/-00 Pu-241 8.70E+02 5.92E+/-02 3.48E+01 Arn-241"5 )

2.58E+/-01 1.75E+/-01 1.03E+00 Cm-243/244 2.90E+01I 1.97E+01

1. 16E+00 (1) Bold indicates those radionuclides considered to be hard to detect.

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE.

(3) The Operational DCGL is equivalent to seventeen (17) mremlyr TEDE.

(4) The required MDC is equivalent to one (1) inern/yr TEDE.

(5) Americium-24 1 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Fifteen (15) samples were collected and analyzed during characterization, as discussed in Section 2.

The mean and variability of Cs-137, Co-60 and Sr-90 in soil in this survey unit was determined during characterization and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been Revision 0 8

Revision 0 8

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5. 1-11, "Preparation of Final Status Survey Plans".

The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

Characterization sampling was used to determine concentration variability.

The DQO process determined that Cs-137, Co-60 and Sr-90 would be the radionuclides of concern in survey unit 95 14-0000 (refer to Section 3).

The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Sr-90) are considered in the survey design.

Other radionuclides identified during FSS were evaluated to ensure adequate survey design.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS.

The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 3 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.91 to maintain the relative shift (A/ay) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package Revision 0 9

Revision 0 9

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARS SIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

Survey design specified fifteen (15) surface soil samples for non-parametric statistical testing.

The sampling locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy.

A random sampling pattern was selected for sample design, which is appropriate for a Class 3 area.

Judgmental sampling was included as a feature of this survey design to investigate suspect areas and account for any anomalies identified in the field.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System.

These coordinates were integrated with a Global Positioning System (GPS) to locate sample points in the field.

Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Revision 0 10 Revision 0 10

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Table 3 -Sample Measurement Locations identified for Non-parametric Statistical Testing with their Associated GPS Coordinates Designation~1 )

Northing Easting 9514-0000-OOIF 236741.85 667927.36 9514-0000-002F 237003.25 667873.14 95 14-0000-003F 237085.45 667945.93 95 14-0000-004F 236983.70 668065.43 9514-0000-005F 237019.53 668113.40 95 14-0000-006F 236767.82 668303.42 95 14-0000-007F 236748.52 668164.06 95 14-0000-008F 236824.04 668034.55 9514-0000-009F 236844.16 668132.20 9514-0000-01OF 237039.56 667907.90 95 14-0000-01 IF 236802.66 668316.63 9514-0000-012F 236719.09 668072.91 9514-0000-013F 236719.44 668148.57 9514-0000-O14FIFS 236883.83 667854.95 9514-0000-Ol5F/FS 236883.46 667825.50 95 14-0000-010J2 )

236892.29 667921.64 9514-0000-01 7J (2) 236870.09 668002.62 9514-0000-01 8j(2) 236794.48 668068.12 9514-0000-019B 13 )

Scan Area #4, Grid #01 7

"" denotes Final Status Survey sample location, "FS" denotes Field-Split sample, "J" denotes Judgmental sample and "B" denotes Investigative sample location.

(2 Denotes samples collected to support addendum #1 to the FSSP.

(3) Denotes investigative sample location at elevated gamma scan location identified during support of addendum #1 to the FSSP.

Although Procedure RPM 5.1-11 only specified that 5% of the samples are required to be selected for HID analysis, two (2) soil samples or 13% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HID radionuclides specified in the LIP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was determined to be 13% of fifteen (15) samples.

Revision 0 I I Revision 0 11

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD The LTP does not require a specific scanning coverage for Class 3 survey units.

The fraction of scanning coverage is determined during the DQO process with the total area, and location(s) based on the likelihood of finding elevated activity during FSS. Survey data collected to date indicates a low probability of finding areas of elevated activity. Nevertheless, the identification of discrete sources of elevated activity in 1980 justifies some scan coverage.

Based on the historical site assessment and the characterization data available, it was determined that three (3) original scan areas were established. The total surface area to be scanned was approximately 10% of the survey unit.

Additionally, Addendum #1 to the FSSP established the need for a fourth scan area under the "8-plex" trailer complex on the asphalt that was to remain after license termination. A map of the scan grid locations is provided in Attachment 1.

For this Class 3 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Table 4-Synopsis of the Survey Desig-n~'

Feature Design Criteria Basis Survey Unit Land 1877M2 Based on AutoCAD-LT and Area 1877Visual Sample Plan calculations Type I and Type 2 errors were Number of 15 random (in addition 0.05, sigma was 0.04 pCi/g, and Meaurmetsto 3 biased and I the LBGR was adjusted to 0.91 to Measremntsinvestigative) maintain Relative Shift in the range of I and 3.

5.38 pCi/g Cs-137 Administratively set to achieve Operational DCGL 2.59 pCi/g Co-60 seventeen (17) mremlyr TEDE (2) 1.05 pCi/g Sr-90 Soi Inestgaton 5.38 pCi/g Cs-137 The Operational DCGL meets the SoLeIvestgto 2.59 pCi/g Co-60 LTP criteria for a Class 3 survey Leel1.05 pCi/g Sr-90 unit Approximately 10%

of the area. Addendum The LTP does not require any Scan Survey Area

  1. 1 to the FSSP required scnigovrefrCls3 Coverage 25% of the surface area Surnngcveyag UnitCls.

of asphalt that is toSuvyUis remain, to be scanned.

Scan Investigation Detectable over Administratively set to achieve Level background seventeen (17) mrem/yr TEDE (2)

(1) The survey design used a much smaller value for the Operational DCGL than provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning this FSS.

(2) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)

Revision 0 12 Revision 0 12

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD

5.

SURVEY IMPLEMENTATION Final status survey field activities were conducted under a detailed FSSP 9514-0000 that included the implementation of a job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Three (3) original scan areas were established that constituted approximately 10% of the surface area of Survey Unit 9514-0000. Grid lines, one (1) meter wide, were painted on the ground of each of the three (3) scan areas. A background survey was performed around the survey unit and it was determined that the range of background measurements, using a Eberline E-600 with a SPA-3 sodium iodide detector, was varied from 4,410 counts per minute (cpm) to 7,550.

As previously stated, Addendum #1 to the FSSP established the need for a fourth scan area under the "8-plex" trailer complex on the asphalt that was to remain after license termination. A map of the scan grid locations is provided in.

The scan areas were established and each area was scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector.

The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.

Approximately 10% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample fixed measurement locations were identified and marked with a surveyor's flag or paint for identification. At each sample fixed measurement location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

As part of the survey design, several additional alternate sample locations were selected randomly, as determined by using Visual Sample Plan (VSP), in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Fifteen (15) surface soil samples were collected for non-parametric statistical testing and packaged in accordance with Haddam Neck Plant (I-NP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Revision 0 13 Revision 0 13

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Two (2) samples (9514-0000-009F and 9514-0000-010F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of two (2) samples (95 14-0000-014F and 9514-0000-015F) for "split sample" analysis.

Follow-up sampling was conducted at the one (1) elevated measurement location that was identified.

Three (3) judgmental sample locations were collected based on the requirements identified in Addendum #1 to the FSS plan, by the FSS Engineer.

A map identifying all of the sample locations is provided in Attachment 1.

6.

SURVEY RESULTS All field survey activities were conducted from February 27 to April 10, 2007.

On February 27, 2007, three (3) original scan areas, that comprised approximately 10% of the total surface area for the survey unit, were scanned for elevated radiation levels.

Additionally, on April 10, 2007, Addendum #1 to the FSSP required that approximately 25% of the surface area of asphalt remaining at the location of the former "8-plex" should also be scanned.

One (1) elevated measurement location was identified during scanning. An investigative sample was collected at the location of the elevated measurement.

Table 5 provides an overview of the scan area survey. Attachment 1 contains a map that identifies the locations of the three (3) scan grids and the additional asphalt area. All scan results are provided in Attachment 2.

Revision 0 14 Revision 0 14

WEST PRIMARY PARKTNG LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Table 5-Scan Area Results Highest Range of

>Elevated Investigation Scan Grid Logged Action Action Reading Sample (2 )

Area

  1. Is Reading Levels Level Identification

______(kcpm)

(kcpm) (1')

(2) 1 1-5 5.87 6.06-6.90 NO 1-5 6.80 7.24-7.38 NO 2

6-10 6.32 6.27-7.34 NO 11-12 5.55 6.66-6.87 NO 1-5 7.73 7.69-8.47 NO 6-10 6.70 6.34-8.01 NO 3

11-15 7.28 5.36-7.71 NO 16-17 5.70 6.50-7.60 NO 1-4 12.3 6.78 YES 9514-OO-ER-4-I-OI 9514-0000-019B 5-8 5.69-<6.67 6.67 NO-4 (3) 9-12 5.78-<6.78 6.78 NO-13-16 5.49-<6.45 6.45 NO The action level is based on a measurement above ambient background in accordance with the FSSP.

(2) "ER" denotes Elevated Reading, "B" denotes Investigative sample location and "-" denotes no value for that field.

(3) Scan area #4 was established to comply with the scan requirements identified in Addendum #1 of the FSSP which required that approximately 25% of the asphalt, under the "8-plex" trailer complex, would be scanned. Therefore sixteen grids were established on the asphalt that was to remain and every fourth grid, or four (4) of the sixteen (16) total grids were scanned, or 25%.

On February 28, 2007 fourteen (14) of the fifteen (15) samples identified for non-parametric statistical testing were collected. One (1) of the original fifteen (15) samples, sample number 9514-0000-008F, was located under the "8-plex" trailer complex and collected on April 10, 2007 after the complex was removed.

Additionally, on April 10, 2007, three (3) judgmental samples and one (1) investigative sample were collected from the soil beneath the asphalt, per Addendum #1 to the FSSP. The samples were designated as 9514-0000-016J, 9514-0000-017J, 9514-0000-018J and 9514-0000-019B.

Revision 0 15 Revision 0 15

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Material Service Requisition (MSR) numbers 07-00 103 and 07-00 144 were generated to cover the analysis of the samples at the approved off-site laboratory.

The fifteen (15) sample locations identified for non-parametric statistical testing along with the three (3) judgmental samples and the one (1) investigative sample locations were scanned over approximately a one (1) meter radius for elevated radiation levels, in accordance with the FSSP.

Table 6 provides an overview of the scan results for sample measurement locations.

A map identifying all of the sample locations is provided in Attachment 1.

Revision 0 16 Revision 0 16

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Table 6-Scan Results for Sample Measurement Locations Sample Measurement Highest Logged Action Level (2)Lel(3 Location ()Reading (kcpm)

> ActionLel(3 (kcpm) 9514-0000-OOIF 5.68 6.48 NO 9514-0000-002F 6.11 7.61 NO 9514-0000-003F 5.85 6.48 NO 9514-0000-004F 6.21 6.99 NO 9514-0000-005F 6.49 7.32 NO 6514-0000-006F 7.42 8.15 NO 9514-0000-007F 7.10 7.96 NO 9514-0000-008F 5.35 6.48 NO 9514-0000-009F 7.24 7.65 NO 9514-0000-01OF 5.70 8.13 NO 9514-0000-01lIF 7.53 9.26 NO 9514-0000-012F 6.96 7.50 NO 9514-0000-013F 6.43 7.67 NO 9514-0000-014F 6.61 7.91 NO 9514-0000-015F 6.87 7.24 NO 9514-0000-016J 5.66 6.78 NO 9514-0000-017J 6.78 7.87 NO 9514-0000-018J 6.26 7.43 NO (1)"F" denotes Final Status Survey sample location and "J" denotes Judgmental or Biased sample location.

(2) The action level is based on a measurement above ambient background in accordance with the FSSP.

(3) FSS sample plans require movement of the sample measurement location to the area within the one (1) meter radius yielding the response above the action level The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC, Charleston, South Carolina.

The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated duplicates, the three (3) judgmental samples and one (1) investigative samples using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDCs.

Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).

Cs-13 7 was identified in seven (7) of the fifteen (15) samples collected for non-parametric statistical testing. Co-60 was not identified in any of the fifteen (15) samples collected for non-parametric statistical testing. Sr-90 was identified in two (2) of the fifteen (15) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the samples indicated that Cs-137 was present at levels that are similar to the concentrations Revision 0 17 Revision 0 17

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.

Table 7-Summary of Soil Sample Results Fraction of Sample Number Cs-137 Co-60 Sr-90 the pCilg pCilg pCilg Operational DCGL (1)(2) 9514-0000-OOIF 4.22E-02

1. 17E-02 7.52E-03 0.020 95 14-0000-002F 2.5 1 E-02 1.40E-02 9.72E-03 0.019 9514-0000-003F 1.83E-02 6.70E-03 4.68E-03 0.010 951 4-0000-004F 2.57E-02 4.04E-03 3.59E-02 0.041 9514-0000-005F 2.59E-02

-5.42E-03 5.20E-03 0.010 95 14-0000-006F 7.25E-02

-9.79E-03 7.99E-05 0.014 951 4-0000-007F 2.29E-02

-3.77E-03 3.04E-02 0.033 95 14-0000-008F

-1.73E-03

-5. 12E-04

-1.46E-02 0.000 9514-0000-009F 6.27E-03 2.24E-04 4.71E-03 0.006 9514-0000-01OF 1.41E-02 1.31E-02

-2.34E-03 0.008 9514-0000-011F 4.48E-02 8.17E-03 9.49E-03 0.021 9514-0000-012F 2.29E-02 2.LOE-02

-9.25E-03 0.012 9514-0000-01 3F

-9.25E-03

-1.30E-02 2.76E-03 0.001 9514-0000-014F 9.54E-02 2.50E-02 9.02E-03 0.036 9514-0000-015F 3.26E-03 2.04E-02 1.70E-02 0.025

()The Operational DCGLs are 5.38 pCi/g for Cs-137, 2.59 pCilg for Co-60 and 1.05 pCi/g for Sr-90 from Table 2 and are used in conjunction with the unity rule.

(2) Negative values were not used when determining the fraction of the Operational DCGL.

The off-site laboratory also processed two (2) samples for HTD analysis (other than Sr-90 which was analyzed for in each sample) as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. One (1) sample, 95 14-0000-009F, met the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) for tritium. No other HTD radionuclides, other than Sr-90, met the accepted criteria for detection.

Additionally, all HTD radionuclide, other than Sr-90, met the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCCL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Two (2) samples or thirteen percent (13%), of the fifteen Revision 0 18 Revision 0 18

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD (15) total samples collected for non-parametric statistical testing were selected for split sample analysis which exceeds the 5% minimum required by the LTP.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey."

Split samples 95 14-0000-014F/FS were assessed and it was determined that there were low resolution ratios (<4) for both Cs-13 7 and Co-60. The agreement range could not be established because NRC Inspection Procedure 84750 does not address resolution ratios below 4. Therefore, a determination of the acceptability for such low rations cannot be made. However, Potassium-40 (K-

40) was found to be present at an acceptable level of agreement. Therefore, no further action was warranted.

Split samples 9514-0000-015F/FS were assessed and it was determined that there were low resolution ratios (<4) for both Cs-137 and Co-60. The agreement range could not be established because NRC Inspection Procedure 84750 does not address resolution ratios below 4. Therefore, a determination of the acceptability for such low rations cannot be made. However, Potassium-40 (K-

40) was found to be present at an acceptable level of agreement. Therefore, no further action was warranted.

The sample analysis vendor, General Engineering Laboratories,

LLC, Charleston, South Carolina, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 3 and Attachment 4 for data and data quality analysis results.
8.

INVESTIGATIONS AND RESULTS A total of three (3) judgmental sampling locations from the soil beneath the asphalt were collected and analyzed for the radionuclides of concern identified in the FSSP. The locations were selected randomly by VSP.

One (1) investigative sample was collected at a elevated scan location identified within the area identified for supplemental scanning in Addendum #1 to the FSSP.

Gamma spectroscopy and Sr-90 analyses was performed by the off-site laboratory to the required MDC. None of the samples exceeded 6.2% of the Operational DCGL.

No further action or investigations were required (see Table 8).

Revision 0 119

WEST PRIMARY PARKTNG LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Fraction of Sample Number Cs-137 Co-60 Sr-90 the pCilg pCilg pCilg Operational

__________DCGL (2

)(3

)

9514-0000-01 6J

-6.62E-03 1.54E-02

-1.1 5E-02 0.006 9514-0000-017J 7.34E-03 1.50E-02 5.73E-02 0.062 9514-0000-01 8J

-4.1 7E-03

-2.37E-03 1.79E-02 0.016 9514-0000-019B

-1.38E-02 2.l8E-02 4.84E-02 0.055

(") "F"' denotes Final Status Survey sample, "J" denotes Judgmental sample and "B" denotes Investigative sample location.

(2) The Operational DCGLs from Table 2 are 5.3 8 pCilg for Cs-13 7, 2.5 9 pCi/g for Co-60, 1.05 pCi/g for Sr-90 and are used in conjunction with the unity rule.

(3) Negative values were not used when determining the fraction of the Operational DCGL.

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN Sample location number 95 14-0000-008F was initially not accessible due to the location of the "8 plex" trailer complex and was able to be collected only after the trailer complex was removed.

Addendum #1 to the FSSP was written to address the decision to leave the portion of the asphalt that was located under the "8 plex" trailer complex. Based on the requirements provided in Section 5.7.3.2.3 of the LTP which states that the portion of the paved area that remains were surveyed for radioactivity both on the surface and beneath the surface, a fourth scan area and three (3) judgmental sampling locations for the soil beneath the asphalt were collected and analyzed for the radionuclides of concern identified in the FSSP.

No other changes to the FSSP were made.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.

The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Revision 0 20 Revision 0 20

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The standard deviation was slightly less than the value used for the survey design. This would indicate that the number of samples collected was sufficient to meet the Operational DCGL. The mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was 16% of the standard deviation which indicates some skewness in the data.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates a positive skewness as confirmed by the calculated skew of 1.24.

Since Co-60 was not identified (i.e., a result greater than two (2) standard deviations uncertainty) in any of the fifteen (15) samples collected for non-parametric statistical testing, the data was not used to determine the adequacy of statistical testing for this survey unit.

For Sr-90, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were at extremely low levels where such variation is to be expected. The difference between the mean and median was 16.5% of the standard deviation which indicates a small skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows a slightly positive skew as confirmed by the calculated skew of 0.73.

All data, assessments, and graphical representations are provided in Attachment 3 and Attachment 4.

12.

ANOMALIES The anomalies associated with the disagreement between the field splits was presented in Section 7. The source of the disagreement for Cs-137 and Co-60 is likely due to extremely low levels of activity being reported and the statistical uncertainties associated with the comparison of very small numbers. Standard statistical tests, ratio comparisons and skew, may not provide the same information at extremely low numbers as compared to higher numbers.

Revision 0 21 Revision 0 21

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD No other anomalies were noted.

13.

CONCLUSION Survey Unit 9514-0000 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

Cs-137 and Sr-90 were used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected.

The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly'designated as Class 3.

The dose contribution from soil is 0.25 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is two (2) mremlyr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations and footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo JSC 06-024); therefore, the dose contribution from future groundwater is zero (0) mremlyr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 2.25 mremlyr Total Effective Dose Equivalent (TEDE). Therefore, Survey Unit 9514-0000 is acceptable for unrestricted release.

Revision 0 22 Revision 0 22

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 23 Revision 0 23

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 1 (FIGURES)

Leen

=Pond

= Surface Land Area Added to Survey Area 9514 from Survey Unit 9506-0000

= Surface Lind Area assigned to Survey Unit 9514-0001 09514-0000-005F 9313-0000 14-0000-003F09514-0000-004F 0

O = Sample Loctions for Non-parametric Testing O =fiudginental and Investigative sample Location 09514-0000-009F i14-000-002F 95-14-0000 9514-0000-0 17J 0 95,A4-0000-005F 09514-0O 0

%-1 n0-1j0540 9514-0000-016J 9514-CYOO-1J054O Not-o9514-0000-014F 09514-0000-0151' 09374--000--012F 0

60 120 Feet 93 02-0000 Notes Coordinates ae in NAD2 7 Connecticut State Plane System 9512-0000 Connecticut Yankee A tomic Power Company Sample Location Map for Survey Unit 9514-0000

Leeend Pond

=Surface Land AMeA Added to Survey Area 9514 from Survey Unit 9506-0000

=Surface Land Area assigned to Survey Unit 9514-000 23 7041.

"68)0W.1 2170U2.

668068.

79 236917.32, 668234.25

?.51 SCAN AREA 02

'4.

176888.47, 668232.29 0

= Scan Ame Locations

-9514-0000 236769481, 668292.36 236810.19, 668092.98 Notes 0

60 120 iiiRFmn Note Coordinates al in NAD27Connecticut State Plane System

'.00, 9512-0000 Connecticut Yankee Atomic Power Company Scan Area Locations for Survey Unit 9514-0000

'I.

Pond 9~1*

Added to Survey Area 9514 from Survey Unit 9506-000

= Surface Land Area assiged to Survey Unit 95)4-"00 00.02 6 9313-0000 015 O0 sI7eu~i

~/

00.026

.006 951 4-Oý *0 0.007o0

-0.002 0

0-0.004 00.023 0 -0.009 0

-0.007 NOte a 0.095 00.003

~0007 0

60 120 Fmn 93 02-0000 Notes Coordinats we in NAD27 Connecticut Stale Plane Systemn 9512-0000 Connecticut Yankee Atomic Power Company Cesium-137 Posting Plot for Survey Unit 95 14-0000

Legend

=

Pond

- Surface Land Area Added to Survey Area 9514 from Survey Unit 9506-0000

= Surface Land Area assigned to Survey Unit 9514-"]0 3

0-0.005 9313-0000

007 00.004 00.,

0

= Co-60 esults.p M/g 0.000 9514-000O 0.023o

-0.001 0

00.018 0-0. 004 0-0.013 0

0.02 7 o0.025 00.02 0 owl-02 Notes u

60 120 GZM

=Feat 9302-0000 Notes Coordinates aem i NAD27 Connecticut State Plane System 9512-0000 Connecticut Yankee Atomic Power Company Cobalt-60 Posting Plot for Survey Unit 9514-0000

'I..

Legwed IPond

= Surface Land Arma Added to Survey Arma 9514 from Survey Unit 9506-0000

= Surface Land Area assiffned to Survey Unit 9514-0001 o0.005 9313-0000

'005 00.036 0 0.j O = Sr-90 results in p Cig 0-0.002 0.005 951 4-OiýOO 0.0570

-0.015 0

00.018 0O.030 00.003 0

-0.012 00.009 00.01 7 0-w00 93 02-0000 Notes 0

60 120 Note Coordinates are in NAD27Coeaecticut State Plane SYSte 9512-0000 Connecticut Yankee Atomic Power Company Strontium-90 Posting Plot for Survey Unit 9514-0000

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

SURVEY UNIT 9514-0000 SAMPLE LOCATION SCAN RESULTS Survey Location Lo Log Reading MDCR AcinL AL E-0 Prb Number I

Date ITime (cpm)

I (c-pm)

(cpm) I ("+"=Yes)l Serial # ISerial #'

9514-00-L 00-1-:0; 212 812007' 9t40

.8~0 17 10 9514-00-SL-00-02-0 28207 1:9:5400 1.6.11E+3 jI 1107 11007 W',ýo" 67," 10:29:0 6,63E!,3 I 0E0

.8+31107 10 9514-00-SL-00-02-60l 'V228/2007 j10:47:00 6.211E+03 j1107 1007

~ ;~/2/207

-~1063-~

62Etopa 1.1 2E03ý 7.32E+03'f 11107 1:007 9514-00-SL-00-05-01 2/28/2007 j10:40:00 5.85E+03 I

1107 I1007 954-0-L-0-6-I

/2/207 1

41:00 j 7.E+0 1107 I1007

~ '2/8/2077.

1320i

' 6.8 03>ý 1'.18.E+03.

6096E+03107 07 9514-00-SL-00-07-0 j2/28/2007 13:47:00 6.21E+03 JI1107 1007 54 :-4/1020207 11150-

.5~

1 20E+03, 7732E+03; 1107 1007' 9514-00-SL-00-08-0I 4/10/2007 11:16:00 6.49E+03 I I1107 I1007 6514-00

ý D '0,90I ~2 28/O0 1 31i0 E

5E+0 i.t!E+O3 7.5E,+03 1ý107 10 9514-00-SL-00-09-0 2/28/2007 13:414:00 7.42E+03 II1107 1007

~91~~L00 i0l2/8/00 13:4~0

~9Ei-03` f. 18E+'03 79.6E4-03-110 1007 9514-00-SL-00-11-0 2/28/2007 13:27:00 7.13E&63 1 1

I 1107 1007 4;414~0~L-40b~2

-2Y4/420.07-13:19:00, 5.3 6E403 1'.1E+3 7.03 1107 10 9514-00-SL-00-12-0 4 /18/2007 13:216:00 5.40E+03 I1107 I1007

  • 95 1440 B-00i~0 2/28/2007.1.3:25:"00, ;6'5E+03
1. 15E+03. 7'65E+03:

1107 1007

.951 4-00-SL-00-1 3-0 2/2812007 113:26:00 1 7.53E+03 I

1107 1007 P(%Survey Area RecordsW514%514-OgOOSCAN RESUMTSSAMPLELOCSCANRESULTS 030707.xis14/

/20 1

4/24/2007

SURVEY UNIT 9514-0000 SAMPLE LOCATION SCAN RESULTS Survey Location Log Log Redn DR Ation L.

>A.L.

E-600j Probe Number DaUte Time (cpm)

I(cpm) I (cpm)

I("+"=Yes)I Serial #~Serial #

~51-0~BO~1~0 J2I2071f~Q

0.

A':4+3 i17E3 -'741E+-03

'110 1007' 94-00d-SL-0-14-10 2-/28/2007 v_

14:10:00_ 6.61 E+03 _II 1107 1007

~

/2/207 1~0~:0

.2E4:01 1'.42E+01, 7.24E+~03 1107 1.007 9514'-0O-SL-00-15-0Oj 2/28/2007 110:04:00 I6.87E+03 j Ij1107 J1007

9 5.1.400I-'.'

16q0 0/0 K11:0

.5.66EO3ý 1'."07,E+03, 6.,73E+03-.

1.107, 1,007 9514-00-SL-00-16-0 14/10/2007 11:26:00 5.87E+03 II11107 1007

~9~~0B-;40 4~O/07

'~2,7:-00. &.18E403! 1.,1 8E+03 7.96E+03 1107 1:007 9514-00-SL-00-17-0 4/1 0/2007 I11:28-.001 6.8ý7E03

¶1107 1007

~5:~0-B;~18-,

4/1~97

-1:3O:0ýU.0d

&26t'03:! T'.1,38+03" 7*?39E+03.

0'

,0 9 1440-L0

- I 410/00 1"1:'31:00 I7.05E+030-L01 8-4/

07 1107 I1007 K:%Survey Area Records%514%9514-OOOO'SCAN RESULTS'AMPLELOCSCANRESULTS O307O7.xds24/

/07 2

4/24/2007

SURVEY UNIT 9514-0000 SCAN AREA SURVEY RESULTS Survey Location Log Log Reading I MDCR I Action L. I

>A.L.

I E-600 IProbe Number Date Time (cpm) I(cpm) I(cpm) 1("+"=Yes)l Serial # ISerial #

9514-00~BC01~01-0 j20'9520'5 E+03, 1,:09E+0,3-6.0E03-_

11110 1010ý 9514-00-SC-01-01-012/28/2007 10:03:00[5.87E+03 1110 1010 954-0-C-1-20

/2/207100:0 569+

.,08E+03 6.71E+0

.11 0 951 4-00-SC-01 012128 12007110:10:00 15.38E+03 I' I

1-1110 1010 9'5144 0'-'BC,4P'103 D 2/207 10:12:0 5.,35E+0310E0'63E0 1110 1010 9514-00-SC-01-03-01.2/28/2007 10:O2ý2:'O00 150.0E+031 1110 1010

'A;, ;!-04 2.10 1,05E+03,6 43E+03'j 31 OW0~

9514-00-SC-01-04-012/28/2007 10:30:00 15.08E+031 1110 1i o

1010 954~0-C015-~2/8/07f0:,1:00 5.05EtQ3 1-.01 E+03 6,.06,E+03

'1110 1010 9514-00-SC-01-05-0 2/28/2007110:44:00 15.27E+031 1110 1 1010 951-0 WBC0201 V2.27/207 -.1,3:1!3:0oQ,7ý'55E4iý03' 1.24E+03 8,,79E+03 1,107 1:007 9514-00-SC-02-01-0 2/27/2007113:17:0O1 6.80E+0311 1107 11007 90;"

.5+3 11:07 1007 9514-00-SC-02-02-0 2/27/20071 13:21:0 16.08E03 1.1E0 72E 1107 1007 95i400-CZ0-03-0, 2/27/2007.13.,21.00pp16A1Et03_1..14E+03

§L5E-+0

.11.07 1007 9514-00-SC-02-03-01I2/27/200-7 1-3:24:0-0 16.76E+03 F Er7=10 1007

'954~0-G?2'4-0.227207 3:4~0 ~2E+

344E+0$_

1

~5E+

11,07 1,007.

954-0-G-2 I2/27/2007_j13.27-00 6,.,22E+03 110 1007ý 9.14006C2

./2/2071328006.5E031.3E037.8E03


1-7 ~0 9514-00-SC-02-05-0 I2/27/2007 13:30:00 6.05E+03 I I1107 1007 51-0Bb205-0-:2127/20T1:00 644E*0ý.1.13IAE+03. 7.268E+0 3128-0 11,07 1.007 9514-00-SC-02-06-01I2/27/20

[13:33:00 16.032E031J 1107 1007 p9514 0B~7: 2/7207

.30,500' 6214E+0.3 1-13E+03, 7.34E1+03'-

1107 1,0107 9514-00-SC-02-07-0 12/27/20071 13:33:00 1 6.82E+03 1-10100 S227/20.07ý 11:16900 5.E+03 1,136E+03 -.7 6.6Et03, ______

111 1010 9514-00-SC-02-07-012/27/2007113:22:00 15.85E+031 r--

-il 116-1010-95-140-'C0~8~

2tQ-08'7-2/2 ý/20O7,13.1 3:23:00 5.246E+03 1.03E+03.6.627E+,03

.11,10 1.01.0.

9514-00-SG-02-09-012/27/2007 [T3:22:00 5.67E+03 111106-1010 956,1 4-0ýýB.0-B02- 09-0.2/27`/20074 1.

123:28001 614,5M5E.3 03 6;.27E+03 1110

-' 101 9514-00-SC-02-10-012/27/20071 13:326:00 1 5.33E+031 1

I 110 1ý1010 954-

,to~2-1-./720 13320 n,5.9E0 i.0E+0

-ME+03 111,10 10 9514-00-SC-02-1 1-012127/2007 13:32:00 15.65E+031

-11,110 1 1010

'9-5 1*-00-BC-!02-12-0O 2/27/2007 '13:36:00* 5-78E,+03 '1.09E+03 6.87E+03 1110 101:0, 9514-00-SC-02-12-01 2/27/200-7]-1:39: 65.39E+03 11 1010 K:%Survey Area Recards%9514X9514-ODOOaSCAN RESULTSSCAN AREA RESULTS 030707.xis 13720 1

3/7/2007

SURVEY UNIT 95 14-0000 SCAN AREA SURVEY RESULTS Survey Location Log ILog 7r Readin~g MDCR Action L.

>A.L.

E,600 Probe Number Date Time I(cpm)

(cpm)

(cpm) I("+"=Yes)

Serial #

Serial #

.13i500-

,E W

'143 11107 "1007 9514-00-SC-03-'1'-0212/7/20071 13:550 1.97E+03 L.9E0 1107+0 951400BC03020 I21Z713:56:00 7i-25E*'03 -11;2!E0 E+03-0 17 1007 9514-00-SC-03-02-0212/7/20071 I13:58.00 7.1 E0-31 11077 1007 9514:

00B-30.7J7?0 35:0713+3

.1 03 8.3,4&M0 1007______

9514-00-SC-03-03-0 2/27/2007114:01:00 1 7.73E+031

-i11.07 1007::

9*5~40~3~90.2171007, 1.4:0 1:00,6A6E-1.7E+03 T.85E+03 0710 951 4-00-SC-03-04-012/27/2007l 14:03:00 -6.83E+031 95 -QBCQ

502127/2007 4040 6-.54EtR3 1.1 5E+03 7.69E+03 11___07__1007__

9514-00-SC-03-05-012/27/2007114:06:00 L6.46E+03 I

1107 1007 9514.j0-BC~0306-02I2/200.T 140:.

6.5E011E0

.7E+03,,

A. 1107.

1007.

9514-00-SC-03-06-0 [2i27/20071 14:09:0016.64E+03_

1107 1007 951~00C-0-0~412'11/2071$35:

j95.3E 3 1.04E+0

-3,4E*.03110 Qi.

9514-00-SC-03-07-0 2/27/2007[1:00 6.3+0 1110 100-

,jZQ07 :0

.6.3E*03 i1J8E+03--!

&8.OE0'3-,Ii1~

0 9514-00-SC-03-09-0 12/27/2007 140 70f66E+03 1 I

Jiio0 1010 951-09B-03:1-2Y 1Z72007-14:07:00-ý 6.277E+03, 1.13E+03.7.34E+03 1110 1010 9514-00-SC-03-10-012/27/20071 14:08:00 16.623E036 F Iý r

11-10 ii60

~ ~141000 655ýQ 116+0 7i1+0 11110 1010 95400S 102/72007 ý,14:140:00 -&7.28E+03ý' 1.7+0- 71104E101 9514-00-SC-03-1 2-012/727/20071 14:17:00 5.01.2E+031 11110 11010

_____________ 2/272907 j41,9;0 4.4I~ 1S 9.4Et*02 J

-53E403 110 11 951400-S-031 3-0[2/7/20714:19:,0,0 4-.79E+310 1010 9514-00-SC-03-14-0_2/27/2007 14:214:00 7.28E+031

___1110 1010 W540-C0-

&2/72,71:50 47E*0,3 TJ.5E+02, 5.042E403, 11.10, 11 9514-00-SC-03-142 2/27/2007j 14:27:00 I5.018E+03 111 1010

__________21/27/2007',

141:0Q6.454,E+03 1.5E0 5..6E0 11,07 1007!_

9514-00-SC-103 2/27/2007 14:130 702E03 3T 1J~10 1

10107 540 BC39 7/20071 114:*.459+3i5+3E+03 10 10T

'0 9514-00-SC-03-16-0 12/27/2007 14:50 5.70E+03 1

1 1107 j 1007 K:'Survey Ara Roawrds%9514%95I4-OOOGSCAN RESULMSSCAN AREA RESULTS 030707.xts 23720 2

31712007

SURVEY UNIT 9514-0000 SCAN AREA SURVEY RESULTS Survey Location Log Log EReading MDC Action L.

>Aý.L.

E.600 IProbe Number Date Time (cpm) I (cpm) I (cpm) I ('+"=Yes) I Serial # I Serial #

9~4-0B-OJ~§ /2/207~4,16; 00,5.97Et,03 1..10E4+3.7..1 +63' 1 107 1007 19514-O0-SC-03-17-O 2/27/2007

ý 141700

ý-fiý 5~-

83E+0310 K:%Survey Area RecordsA9514X9514-OGOOMSCAN RESULTSSCAN AREA RESULTS 030707.xis 3720 3

3RI2007

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

Laboratories LLC a member o1 The GEL Group INC P0 Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.766.1178 www.gel.com Connecticut Yankee Atomic Power Co.

Soils PO# 002332 Work Order: 181810 SDG: MSR#07-00103 Laboratory ID 181810001 181810002 181810003 181810004 181810005 181810006 181810007 181810008 181810009 181810010 181810011 181810012 181810013 181810014 181810015 181810016 Client ID 9514-0000-OOIF 951 4-0000-002F 95 14-0000-003F 95 14-0000-004F 95 14-0000-005F 95 14-0000-006F 95 14-0000-007F 951 4-0000-009F 9514-0000-01IOF 95 14-0000-01 IF 9514-0000-012F 9514-0000-013F 95 14-0000-014F 95 14-0000-014FS 9514-0000-015SF 9514-0000-015FS flrnhlem 4znhianr

Laboratories LLC a member of The GEL Group INC PO Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.766.1178 March 09, 2007 www.gel.com Mr. Jack McCarthy Connecticut Yankee Atomic Power 362 Injun Hollow Rd East Hampton, Connecticut 06424 Re: Soils PO# 002332 Work Order: 1818 10 SDG: MSR#07-00103

Dear Mr. McCarthy:

GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on March 06, 2007. This original data report has been prepared and reviewed in accordance with GEL's standard operating procedures.

Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-817 1, ext. 4243.

Sincerely, Chery Jones Project Manager Purchase Order: 002332 Chain of Custody: 2007-00043 and 2007-00044 Enclosures nrrhlam cnlvari

Table of Contents General Nlarrative.................................................

1 Chain of Custody and Supporting Documentation..........

5 Data Review Qualifier Definitions......................................

10 Radiological Analysis..................

12 Sample Data Summary........................................

31 Quality Control Data............................................

67

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 181810 SDG: MSR#07-00103 March 09, 2007 Laboratory Identification:-

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on March 06, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 181810001 181810002 181810003 181810004 181810005 181810006 181810007 181810008 181810009 181810010 181810011 181810012 181810013 181810014 181810015 181810016 Sample Description 9514-0000-OOIF 95 14-0000-002F 9514-0000-003 F 951 4-0000-004F 951 4-0000-005F 9514-0000-006F 9514-0000-007F 951 4-0000-009F 9514-0000-01 OF 95 14-0000-01 IF 9514-0000-012F 9514-0000-01 3F 9514-0000-014F 9514-0000-014FS 9514-0000-015F 9514-0000-015FS Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

GEL Laboratories ux PO Box 30712 Chafleston, SC 29417 2040 Savage Road Chadston, 8C029407 P 843.555.8171 F 843.766.1178 2

www.gal.com

Analytical Request Fourteen soil samples were analyzed for FSSGAM and Strontium-90. Two soil samples were analyzed for FSSGAM.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Chery

ýJones Project Manager GEL Laboratories LLc PO Box 30712 Chaleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.555.8171 F 543.70f.1178 3

www.gol.com

List of current GEL Certifications as of 09 March 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas88-065 1 CLIA 42DO904046 California 01151CA Colorado GenEngLabs Connecticut PH-01 69 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87 156 Georgia E87 156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO1 2 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87 156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP TI 04704235-06-Tx U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87 156 Virginia 00151 Washington Cl 641 4

Chain of Custody and Supporting Documentation

.5

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-002 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-00043 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab UseOnly Contact Name & Phone:

Comments:

Jac M~arhy86-26-324Media Sample Container Jac M~arhy86-26-324Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Cd 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority:DEl30D.L[l115 D. Z 7D.

Sample Designation Date Time Comment, Preservation Lab Sample, ID 9514-0000-OOIF 2/28/07 0952 TS G

BP X

95 1 4-0000-002F 2/28/07 1008 TS G

BP X

9514-0000-003F 2/28/07 1030 TS G

BP X-9514-0000-004F 2/28/07 1045 TS G

BP X-9514-0000-005F 2/28/07 1038 TS G

BP X

9514-0000-006F 2/28/07 1341 TS G

BP X-9514-0000-007F 2/28/07 1328 TS G

BP X-9514-0000-009F 2/28/07 1312 TS G

BP X

9514-0000-01IOF 2/28/07 1014 TS G

BP X__

9514-0000-01lIF 2/28/07 1337 TS G

BP X__

9514-0000-012F 2/28/07 11320 TS G

BP X_____

NOTES: P04#:002332 MSR 4: 07-00 103 JZ LUP QA EL Radwaste QA LI Non QA Samples Shipped Via:

Internal Container SFed Ex Temp.: A3_ Deg. C El UPS E] Hand Cus.tody Sealed?

Y'~'

N E

1) Re in 4d By. -A QatVTime
2) Re eived BDate/Time Custody Seal Intact?

t = AJ/l7/D-7 A

EL Other

3) Relinquished By Date/Time
4) cjeived By bate/Time N___________

Bill of Lading #N

5) Relinquished By Date/Tim
6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-002 Connecticut Yankee Atomic Power Company Chain of Custody Form N.20-04 362 lnJun Hollow Road, East Hampton, CT 06424 N.20-04 860-267-2556____________________

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Commnents:

86026-324Media Sample Container Jack McCarthy 86-6-94Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road

&L Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: E] 30 D. []i 15 D.

7 D.

Other:

Sample Designation Date Time Comment, Preservation Lab. Samrple ID 9514-0000-013F 2/28/07 1325 TS G

BP X

9514-0000-014F 2/28/07 1410 TS G

BP X__________

9514-0000-014FS 2/28/07 1410 TS G

BP X

9514-0000-015F 2/28/07 1002 TS G

BP X__________________

9514-0000-015FS 2/28/07 1002 TS G

BP X

NOTES: P0O#

002332 MSR #:07-00 103 Z

LTP QA

[I Radwaste QA

[I Non QA Samples Shipped Via:

Intetrnal Container SFed Ex Temp'.: _I Deg. C El UPS LIHand Cust ody Sealed?

______________________YX N. [

1) Relinquis,

,Date/Time

2) Re eived B" Date/Time

ýCu.stody Seal Intact?

3/r/o7E o9~3,fOtherJ

3) Relinquished By Date/Time
4) Oceiv-ed B y 6ate/Time Y)e N El Bill of Lading#
5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee:

Statement of Wori for Analytical Lab Services

-CY-ISC-SOW-OOI Samnpl Ch-in List.

Date/Time Received.: 316 4/0.

c SDG#.K:

MLL-1ic

-Work Order Number:

  • //0 Shipping Cdntainer 5D

/'

4 3b-6.5' S.

Chain of Custody it Z0022004t3,2oX~'

I I.

Custody Seals. ozii shipping container intact?...

Yes (iJNo (

2.

Custody Seals dated and signed?

Yes'L.No[I-

3.

Chain-of-Custo*Jy record present?

Yes NoI[No 4..

Coolertemperature.

13'

5.

Vermiiculite/packing materials is:

Wet [

DrTy 6.-

Number of samples in shipping contalner 1

7.

Sample holding times exceeded?

Yes[JNoJ~

10.

Were any anomnalies idendified in san.

II Description of anomalies.(include sonr pie receipt?

Yes'[

NO[3 iple numbers):

Sampleý CustodiaiiLab~oratory:

a,.3/-

Tclcphomed to:-

O By

rSAMPLE RECEIPT & REVIEW FORM PM use only Client:

jA/KSDG/ARCOCIWork Order:

Date Received:

3/, i PM(A) Review 7(5 sure nof ýcoulforming items are resolved prior to signing):

Received By:

p___________________

Sample R ipt Criteria 0

Comments/Qualifiers (Required for Non-Conforming Items) 1Shipping containers rec*e Circle Applicable: seals broken damaged container leaking container other (describe) intact and sealed?

Samples requiring cold Circle Coolant #

ice bags blue ice dry ice none.other describe; 2 preservation within (4 +/I-2 C\\)?

,Record preservation method.

3Chain of custody documents included with shipment?

4 Sapecontainers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed?

5Samples requiring chemical S pi tIs. containers affected and observed pH:

lpreservation at proper pH?-

6 JVGA vials free of headspace Sample and containers affected:

-(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) 8Samples received within holding Id's and tests affected:

time?

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

,10Date & time on COC match date Sample ID's affected:

& time on bottles?

,,Number of containers receivedSapeIsafctd match number indicated on COC?

12COC form is properly signed in 12relinquished/received sections?

14 Air Bill1,Tracking #'s, &

Additional Comments T~ RSO RAD Receipt #

Suspected ~

~

1 aaadIfrmto *If > x2 area background is observed on samples identified as "non U~

regulated/non-radioactive", contact the Radiation Safety group for ffirth

~investigation.

A Radiological Classificat~ion?

Z Maximum Counts Observed*:'

Lto Ce jPCB Regula-ted?-

Shipped as DPI H-azardous C Material? If yes, contact Waste J

Hazard Class Shipped:

lManager or ESH Manager.

UN#:

PIRegulated as a Fore'i-gn Soil?

Z7" PM (or PMA) review of Hazard classification:

Initials Date:

Data Review Qualifier Definitions 10

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less then value reported Result is greater than value reported ARPD of sample and duplicate evaluated using +/-RL. Concentrations are <SX the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL c sample value c PQIJ BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by SC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOB-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SB is >10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UT Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary packaqe, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories LLC P0 Box30712 Chafleston, SC 29417 2040 Baangs Road Charleston, SC 29407 P 843.556.8171 F 843.755.1178 www.gsl.com 11

RADIOLOGICAL ANALYSIS 12

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 181810 Method/Analysis Information Product:

Product:Aiphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615126 615119 615118 Sample ID 181810008 181810009 1201290637 1201290638 1201290639 1201290640 Client ID 951 4-0000-009F 95 14-0000-01OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(95 14-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibraltion Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

13

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (9514-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 14

Product:

Product:Aiphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-II-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-02 1 Batch Number:

Ash Soil Prep Dry Soil Prep 615127 615119 615118 Sample ID 18 1810008 181810009 1201290641 1201290642 1201290643 1201290644 Client ID 951 4-0000-009F 95 14-0000-01OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(951 4-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (95 14-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

15

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-II-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

615128 Prep Batch Number:

615119 Dry Soil Prep GL-RAD-A-021 Batch Number:

615118 16

Sample ID Client ID 181810008 9514-0000-009F 181810009 9514-0000-01OF 1201290645 Method Blank (MB) 1201290646 181810008(951 4-0000-009F) Sample Duplicate (DUP) 1201290647 181810008(95 14-0000-009F) Matrix Spike (MS) 1201290648 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (9514-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 181810009 (9514-0000-010F) was recounted due to high MDA. Samples 1201290645 (MB),

1201290646 (9514-0000-009F), 181810008 (9514-0000-009F) and 181810009 (9514-0000-010F) were recounted due to spectral interference.

17

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:

EML HASL 300, 4.5.2.3 Prep Method:

Dry Soil Prep Analytical Batch Number:

615304 Prep Batch Number:

615118 18

Sample ID 181810001 181810002 181810003 181810004 181810005 181810006 181810007 181810008 181810009 181810010 181810011 181810012 181810013 181810014 181810015 181810016 1201291074 1201291075 1201291076 Client ID 95 14-0000-OlIF 95 14-0000-002F 95 14-0000-003F 951 4-0000-004F 95 14-0000-005F 95 14-0000-006F 95 14-0000-007F 951 4-0000-009F 95 14-0000-01OF 95 14-0000-011IF 95 14-0000-012F 9514-0000-013F 95 14-0000-014F 9514-0000-01 4FS 9514-0000-015SF 9514-0000-015FSF Method Blank (MB) 181810001(9514-0000-001 F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810001 (9514-0000-OO1F).

QC Information All of the QC samples met the required acceptance limits.

19

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The duplicate and the sample, 1201291075 (9514-0000-QOIF7) and 181810001 (9514-0000-G01F), did not meet the relative percent difference requirement for Ac-228 and Tl-208, however they do meet the relative error ratio requirement with a value of 1.86 for Ac-228 and 1.31 for TI-208.

Qualifier information Qualifier Reason Analyte U'

U' U'

Data rejected due to high counting uncertainty.

Bismuth-212 Data rejected due to high peak width.

Data rejected due to interference.

U' Data rejected due to low abundance.

Cesium-134 Manganese-54 Bismuth-21 2 Cesium-134 Potassium-40 Sample 181810005 181810013 181810014 181810015 181810010 181810016 181810012 181810006 181810011 181810012 181810010 Method/Analysis Information 20

Product:

Product:GFPC, Sr9O, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-02 1 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615295 615119 615118 Sample I1D 181810001 181810002 181810003 181810004 181810005 181810006 181810007 181810008 181810009 181810010 181810011 181810012 181810013 181810014 181810015 181810016 1201291053 1201291054 1201291055 1201291056 Client ID 95 14-0000-00 IF 951 4-0000-002F 951 4-0000-003F 95 14-0000-004F 95 14-0000-005F 95 14-0000-006F 951 4-0000-007F 951 4-0000-009F 95 14-0000-01OF 9514-0000-011iF 95 14-0000-012F 9514-0000-01 3F 95 14-0000-014F 95 14-0000-014FS 9514-0000-015SF 9514-0000-015SFS Method Blank (MB) 181810010(9514-0000-01 IF) Sample Duplicate (DIJP) 181810010(9514-0000-01 iF) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

21

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810010 (95 14-0000-0111F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:

615131 22

Sample ID Client ID 181810008 9514-0000-009F 181810009 9514-0000-01OF 1201290657 Method Blank (MB) 1201290658 181 810008(9514-0000-009F) Sample Duplicate (DUP) 1201290659 181810008(95 14-0000-009F) Matrix Spike (MS) 1201290660 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (95 14-0000-009F).

QC Information All of the QC samples met the required acceptance lim-its.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

23

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-I1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615129 615119 615118 Sample ID 181810008 181810009 1201290649 1201290650 1201290651 1201290652 Client ID 95 14-0000-009F 9514-0000-01 OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(951 4-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

24

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00' Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (9514-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 25

Product:

Product:Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-i, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 616259 615119 615118 Sample ED 181810008 181810009 1201293431 1201293432 1201293433 1201293434 Client ID 951 4-0000-009F 9514-0000-01OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(951 4-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (95 14-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

26

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

[SC, Tritium Dist, Solid - 3 pCilg Analytical Method:

Analytical Batch Number:

Sample ID 181810008 181810009 1201290665 1201290666 1201290667 1201290668 EPA 906.0 Modified 615132 Client ID 951 4-0000-009F 95 14-0000-01OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(95 14-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

27

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (95 14-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Mtthod/Analysis Information 28

Product:

Product:Liquid Scint C14, Solid Al1,FSS Analytical Method:

Analytical Batch Number:

Sample ID 181810008 181810009 1201290673 1201290674 1201290675 1201290676 EPA EERF C-01I Modified 615134 Client ID 95 14-0000-009F 9514-0000-01OF Method Blank (MB) 181810008(951 4-0000-009F) Sample Duplicate (DUP) 181810008(951 4-0000-009F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181810008 (9514-0000-009F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

29

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performned under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

Iz4 30

SAMPLE DATA

SUMMARY

31

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-00 103 GEL Work Order: 1818 10 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 32

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

9514-0000-OOIF Project:

YANK01204 Sample ID:

181810001 Client ID:

YANKO0l Matrix:

TS Vol. Reev.:

Collect Date:

28-FEB-07 Receive Date:

06-MAR-07 Collector:

Client Moisture:

6.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.430

+/-0.183 0.0807

+/-0.183 0.161 pCilg MJH1 03/07/07 0948 615304 Americium-241 U

-0.0148

+/-0.0972 0.0791 +/-0.0972 0.158 pCi/g Bismuth-212 0.506

+/-0.200 0.152

+/-0.200 0.304 pCilg Bismuth-214 0.459

+/-0.0994 0.0338 +/-0.0994 0.0676 pCi/g Cesium-134 U

0.0487

+/-0.0404 0.0253 +/-0.0404 0.0505 pCi/g Cesium-137 0.0422

+/-0.0376 0.0181 +/-0.0376 0.0361 pCi/g Cobalt-60 U

0.0117

+/-0.0245 0.02 19 +/-0.0245 0.0438 pCi/g Europium-152 U

0.0413

+/-0.0666 0.0535 +/-0.0666 0.107 pCi/g Europium-154 U

0.0955

+/-0.077 0.068

+/-0.077 0.136 pCi/g Europium-ISS U -0.00556

+/-0.0613 0.054 +/-0.0613 0.108 pCilg Lead-212 0.518

+/-0.0715 0.0311 +/-0.0715 0.0621 pCi/g Lead-214 0.436

+/-0.0997 0.0377 +/-0.0997 0.0754 pCi/g Manganese-54 U-0.000608

+/-0.0226 0.019 +/-0.0226 0.03 8 pCi/g Niobium-94 U

0.00747

+/-0.0197 0.0175 +/-0.0197 0.035 pCi/g Potassium-40 8.60

+1-1.04 0.143

+1-1.04 0.285 pCilg Radium-226 0.459

+/-0.0994 0.0338 +/-0.0994 0.0676 pCi/g Silver-108m U -0.00544

+/-0.0206 0.0172 +/-0.0206 0.0343 pCi/g Thallium-208 0.189

+/-0.0471 0.0168 +/-0.0471 0.0336 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U

0.00752

+/-0.0183 0.0143 +/-0.0183 0.0333 pCi/g KSD1 03/09/07 1711 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB 1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified 33

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-OOIF Project:

YANK01204 Sample ID:

181810001 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU NMA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 89 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 89 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-002F 181810002 TS 28-FEB-07 06-MAR-07 Client 5.83%

Proiect:

Client ID:

Vol. Recv.:

YANK0 1204 YANK001 Parameter Rad Gamma Spec Analysis

~ualifier Result Uncertainty LC TPU MIDA.

Units DF Analyst Date Time Batch 1%

Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 Americium-241 U

Bismuth-21 2 Bismuth-2 14 Cesium-134 U

Cesium-137 U

Cobalt-60 U

Europium-152 U

Europium-154 U

Europium-ISS U

Lead-21 2 Lead-214 Manganese-54 U

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U1.4 Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 I J 0.494

-0.141 0.453 0.469 0.0339 0.025 1 0.014 0.0223 0.0282 0.024 0.541 0.547 0.0269 0.0112 10.3 0.469

.1 OE-05 0.144

+/-0.178

+/-0.0945

+/-0.250

+/-0.0944

+/-0.0233

+/-0.0231

+/-0.0215

+/-0.0666

+/-0.0669

+/-0.0615

+/-0.0715

+/-0.0954

+/-0.0282

+/-0.0211

+/-1.07

+/-0.0944

+/-0.0213

+/-0.0376 0.0616 0.0813 0.141 0.0347 0.0223 0.021 0.0194 0.0464 0.0586 0.0557 0.026 0.0339 0.0177 0.01 84 0.156 0.0347 0.016 0.01 89

+/-0.178

+/-0.0945

+/-0.250

+/-0.0944

+/-0.0233

+/-0.0231

+/-0.0215

+/-0.0666

+/-0.0669

+/-0.0615

+/-0.0715

+/-0.0954

+/-0.0282

+/-0.0211

+/-1.07

+/-0.0944

+/-0.0213

+/-0.0376 0.123 0.163 0.281 0.0694 0.0447 0.0421 0.0387 0.0928 0.117 0.111 0.052 0.0678 0.0353 0.0368 0.3 11 0.0694 0.0321 0.0378 0.0346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MIHI 03/07/07 0948 615304 KSDI 03/09/07 1711 615295 0.00972

+/-0.0193 0.0148 +/-0.0193 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 35

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Anallsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-002F Project:

YANKOI1204 Sample ID:

181810002 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, SrOO, solid-ALL FSS 84 (25%-125%)

Strontium Carrier GFPC, Sr9O, solid-ALL FSS 84 (25%-1 25%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certififate-atAn Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-003F 181810003 TS 28-FEB-07 06-MAR-07 Client 6.17%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.497

+/-0.141 0.0508

+/-0.141 0.102 pCi/g MJH1 03/07/07 0949 615304 Americium-241 U -0.00955

+/-0.088 0.0701

+/-0.088 0.140 pCi/g Bismuth-212 0.258

+/-0.221 0.115

+/-0.221 0.231 pCilg Bismuth-214 0.387

+/-0.085 0.0299

+/-0.085 0.0597 pCi/g Cesium-134 U

0.0289

+/-0.0354 0.0207 +/-0.0354 0.0414 pCi/g Cesium-137 U

0.01 83

+/-0.021 0.0194

+/-0.021 0.0388 pCi/g Cobalt-60 U

0.0067

+/-0.0195 0.0174 +/-0.0195 0.0347 pCilg Europium-152 U

-0.0223

+/-0.0532 0.0432 +/-0.0532 0.0864 pCilg Europium-154 U -0.00275

+/-0.0621 0.053 +/-0.0621 0.106 pCilg Europium-ISS U-0.000616

+/-0.051 0.0478

+/-0.051 0.0955 pCi/g Lead-212 0.447

+1-0.0576 0.0253 +/-0.0576 0.0507 pCi/g Lead-214 0.491

+/-0.0831 0.0295 +/-0.0831 0.059 pCi/g Manganese-54 U

-0.0159

+/-0.0197 0.0155 +/-0.0197 0.031 pCi/g Niobium-94 U

0.00161

+/-0.0173 0.0151 +/-0.0173 0.0302 pCi/g Potassium-40 8.25

+1-0.904 0.136

+/-0.904 0.271 pCilg Radium-226 0.387

+/-0.085 0.0299

+/-0.085 0.0597 pCi/g Silver-I 08m U

0.00277

+/-0.0167 0.0145 +/-0.0167 0.0289 pCi/g Thallium-208 0.169

+/-0.0346 0.0158 +/-0.0346 0.0316 pCi/g Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Stro ntium-90 U

0.00468

+/-0.020 0.0162

+/-0.020 0.0371 pCi/g KSDI 03/09/07 1711 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Linits 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Client Sample ID:

9514-O0000-003F Project:

YANK01204 Sample ID:

181810003 Client ID:

YANKOOlI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-004F 181810004 TS 28-FEB-07 06-MAR-07 Client

.497%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL ESS 226 In growth Waived Actinium-228 0.576

+/-0.130 0.0455

+/-0.130 0.091 pCi/g MIHI 03/07/07 0949 615304 Americium-241 U

0.0354

+/-0.0596 0.052 +/-0.0596 0.104 pCi/g Bismuth-212 0.371

+/-0.213 0.108

+/-0.213 0.215 pCi/g Bismuth-214 0.399

+/-0.0776 0.0258 +/-0.0776 0.0515 pCi/g Cesium-134 U

0.0264

+/-0.0319 0.0185 +/-0.0319 0.037 pCi/g Cesium-137 U

0.0257

+/-0.0269 0.0143 +/-0.0269 0.0286 pCi/g Cobalt-60 U

0.00404

+/-0.017 0.0147

+/-0.017 0.0295 pCi/g Europium-152 U -0.0314

+/-0.0486 0.0353 +/-0.0486 0.0706 pCi/g Europium-154 U

-0.0236

+/-0.0549 0.0404 +/-0.0549 0.0807 pCi/g Europium-ISS U

0.0126

+/-0.047 0.0443

+/-0.047 0.0886 pCi/g Lead-212 0.457

+/-0.0549 0.0232 +/-0.0549 0.0464 pCi/g Lead-214 0.475

+/-0.0749 0.0276 +/-0.0749 0.0551 pCi/g Manganese-54 U 0.000633

+/-0.0161 0.0143 +/-0.0161 0.0285 pCi/g Niobium-94 U

0.0141

+/-0.0194 0.0135 +/-0.0194 0.0269 pCi/g Potassium-40 10.1

+/-0.926 0.118

+/-0.926 0.236 pCi/g Radium-226 0.399

+/-0.0776 0.0258 +/-0.0776 0.0515 pCi/g Silver-108mi U -0.00267

+/-0.0138 0.0122 +/-0.0138 0.0243 pCi/g Thallium-208 0.167

+/-0.0339 0.0134 +/-0.0339 0.0268 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 0.0359

+/-0.0216 0.0134 +/-0.0216 0.0314 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Anallysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

-Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-004F Project:

YANK01204 Sample ID:

181810004 Client ID:

YANKOOlI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU NMA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 90 (25%-i125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 90 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-005F 181810005 TS 28-FEB-07 06-MAR-07 Client 5.16%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch A~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.569

+/-0.167 0.0672

+/-0.167 0.134 pCilg MIHI 03/07/07 0950 615304 Americium-241 U

0.01 63

+/-0.0353 0.027 +/-0.0353 0.054 pCi/g Bismuth-212 UI 0.00

+/-0.319 0.137

+/-0.319 0.273 pCilg Bismuth-214 0.375

+/-0.0904 0.0368 +1-0.0904 0.0736 pCilg Cesium-134 U

0.0226

+/-0.0262 0.0235 +/-0.0262 0.047 pCilg Cesium-137 U

0.0259

+/-0.0274 0.0225 +/-0.0274 0.045 pCi/g Cobalt-60 U -0.00542

+/-0.0286 0.0197 +/-0.0286 0.0393 pCi/g Europium-152 U

0.00914

+/-0.054 0.0449

+/-0.054 0.0897 pCilg Europium-154 U

0.0992

+/-0.0753 0.0665 +/-0.0753 0.133 pCilg Europium-I 55 U

0.00387

+/-0.0403 0.0426 +/-0.0403 0.0852 pCilg Lead-212 0.536

+/-0.0701 0.0233 +/-0.0701 0.0467 pCilg Lead-214 0.414

+/-0.083 0.0308

+/-0.083 0.0615 pCi/g Manganese-54 U

0.0161

+/-0.024 0.0216

+/-0.024 0.0431 pCi/g Niobium-94 U -0.0246

+/-0.0217 0.0163 +1-0.0217 0.0325 pCi/g Potassium-40 9.26

+/-0.980 0.141

+/-0.980 0.282 pCilg Radium-226 0.375

+/-0.0904 0.0368 +/-0.0904 0.0736 pCi/g Silver-108m U

0.00368

+/-0.0163 0.0147 +/-0.0163 0.0294 pCi/g Thallium-208 0.187

+1-0.044 0.017

+1-0.044 0.0339 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0052

+/-0.0164 0.013 +/-0.0164 0.0304 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 41

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analy:sis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Client Sample ID:

9514-0000-005F Project:

YANK01204 Sample ID:

181810005 Client ID:

YANKOOlI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr9O, solid-ALL FSS 91 (25%-125%)

Strontium Carrier GFPC, Sr9O, solid-ALL FSS 91 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UL Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificate ofAnaksis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

951 4-0000-006F 181810006 TS 28-FEB-07 06-MAR-07 Client 6.28%

Project:

Client ID:

Vol. Recv.:

YANKOI1.204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.772

+/-0.172 0.0454

+/-0.172 0.0907 pCi/g MIHI 03/07/07 0950 615304 Americium-241 U -0.00491

+/-0.104 0.0859

+1-0.104 0.172 pCi/g Bismuth-212 0.471

+/-0.237 0.107

+/-0.237 0.214 pCi/g Bismuth-214 0.504

+/-0.0839 0.0286 +/-0.0839 0.0572 pCi/g Cesium-I 34 UI 0.00

+/-0.0279 0.0178 +/-0.0279 0.0356 pCi/g Cesium-137 0.0725

+/-0.0289 0.0159 +/-0.0289 0.0317 pCi/g Cobalt-60 U -0.00979

+/-0.0167 0.0135 +/-0.0167 0.027 pCi/g Europium-152 U

0.0173

+/-0.0498 0.0385 +/-0.0498 0.0769 pCi/g Europium-154 U

-0.0167

+/-0.0589 0.0419 +/-0.0589 0.0838 pCi/g Europium-ISS U

0.0509

+/-0.055 0.0506

+/-0.055 0.101 pCi/g Lead-212 0.684

+/-0.0737 0.0234 +/-0.0737 0.0468 pCi/g Lead-214 0.626

+/-0.093 0.0264

+/-0.093 0.0528 pCi/g Manganese-54 U

0.0192

+/-0.0218 0.0126 +/-0.0218 0.0252 pCi/g Niobium-94 U

0.00683

+/-0.0187 0.0141 +/-0.0187 0.0282 pCi/g Potassium-40 10.1

+/-0.880 0.135

+/-0.880 0.270 pCi/g Radium-226 0.504

+/-0.0839 0.0286 +/-0.0839 0.0572 pCi/g Silver-108m U -0.00478

+/-0.0148 0.0127 +/-0.0148 0.0254 pCi/g Thallium-208 0.201

+/-0.0394 0.0136 +/-0.0394 0.0272 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U7.990E-05

+/-0.0165 0.0138 +/-0.0165 0.0326 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 43

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Client Sample ID:

9514-0000-006F Project:

YANKOI1204 Sample ID:

181810006 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificate ofAnalvsis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

951 4-0000-007F 181810007 TS 28-FEB-07 06-MAR-07 Client 6.52%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK00 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.629

+/-0.140 0.0549

+/-0.140 0.110 pCifg MIHI 03/07/07 0951 615304 Americium-241 U

0.00626

+/-0.0608 0.0505 +/-0.0608 0.101 pCi/g Bismuth-212 0.366

+/-0.230 0.157

+/-0.230 0.314 pCi/g Bismuth-214 0.421

+/-0.0923 0.0345 +/-0.0923 0.0689 pCi/g Cesium-134 U

0.0215

+/-0.0246 0.0209 +/-0.0246 0.0418 pCi/g Cesium-137 U

0.0229

+/-0.0215 0.0169 +/-0.0215 0.0337 pCi/g Cobalt-60 U -0.00377

+/-0.0175 0.0142 +/-0.0175 0.0284 pCi/g Europium-152 U

-0.0412

+/-0.0592 0.0437 +/-0.0592 0.0872 pCi/g Europium-154 U

-0.0162

+/-0.0738 0.0515 +/-0.0738 0.103 pCi/g Europium-i 55 U

0.00237

+/-0.054 0.0493

+/-0.054 0.0985 pCi/g Lead-212 0.540

+/-0.0673 0.026 +/-0.0673 0.052 pCi/g Lead-214 0.507

+/-0.088 0.0344

+/-0.088 0.0688 pCi/g Manganese-54 U -0.00136

+/-0.0216 0.0188 +/-0.0216 0.0376 pCi/g Niobium-94 U

-0.0109

+/-0.0217 0.0158 +/-0.0217 0.0316 pCi/g Potassium-40 9.03

+/-0.902 0.129

+/-0.902 0.258 pCi/g Radium-226 0.421

+/-0.0923 0.0345 +/-0.0923 0.0689 pCi/g Silver-108m U

0.0139

+/-0.0201 0.017 +/-0.0201 0.0339 pCi/g Thallium-208 0.191

+/-0.0359 0.016 +/-0.0359 0.0319 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.0304

+/-0.0232 0.0155 +/-0.0232 0.036 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 45

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-007F Project:

YANK01204 Sample ID:

181810007 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1'%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 89 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL ESS 89 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

131 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificate ofAnalvsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-009F 181810008 TS 28-FEB-07 06-MAR-07 Client 6.77%

Proiect:

Client ID:

Vol. Recv.:

YANK01 204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch IN Rad Alpha Spec Analysis Aiphaspec Am241, Cm, Solid ALL FSS Americium-241 U

-0.0808 Curium-242 U

0.00253 Curium-243/244 U

0.0098 Alp/mspec Pu, Solid-ALL FSS Plutonium-238 U

-0.0422 Plutonium-239/240 U

0.111

+/-0.143

+/-0.0972

+/-0.188 0.145 0.0802 0.155

+/-0.144

+/-0.0972

+/-0.188 0.374 0.246 0.394 0.295 0.229 13.0

+/-0.0879 0.098 +/-0.0881

+/-0.147 0.0653

+/-0.147 Liquid Scint Pu241, Solid-ALL ESS Plutonium-241 U

Rad Gamma Spec Analysis

-0.807

+/-7.20 6.09

+/-7.20 Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 Americium-241 Bismuth-2 12 Bismuth-214 Cesium-l 34 Cesium-I 37 Cobalt-60 Europium-I 52 Europium-I 54 Europium-l 55 Lead-21 2 Lead-214 0.666 U

0.00708 U

0.280 0.479 U

0.0271 U

0.00627 U 0.000224 U

0.0107 U

0.0874 U

0.032 0.552 0.478

+/-0.184

+/-0.0347

+/-0.253

+/-0.096

+/-0.0288

+/-0.029

+/-0.029

+/-0.0815

+/-0.0837

+/-0.0534

+/-0.0736

+/-0. 101

+/-0.0251

+/-0.023

+/-1.03

+/-0.096

+/-0.0289

+1-0.050 0.077 0.0284 0.154 0.0346 0.0271 0.0227 0.0243 0.0502 0.0723 0.0473 0.0253 0.035 0.0228 0.020 0.230 0.0346 0.0187 0.0179

+/-0.184

+/-0.0347

+/-0.253

+/-0.096

+/-0.0288

+/-0.029

+/-0.029

+/-0.0815

+/-0.0837

+/-0.0534

+/-0.0736

+/-0.101

+/-0.0251

+/-0.023

+/-1.03

+/-0.096

+/-0.0289

+/-0.050 Manganese-54 U

Niobium-94 U -

Potassium-40 Radium-226 Silver-108m U

Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.012 0,00467 9.15 0.479 0.03 19 0.208 0.154 0.0567 0.308 0.0692 0.0542 0.0454 0.0486 0.100 0.145 0.0945 0.0507 0.070 0.0455 0.040 0.459 0.0692 0.0374 0.0357 0.0337 2.11 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g GXR1 03/07/07 1533 615126 GXR1 03/07/07 1533 615127 GXRl 03/09/07 1223 615128 MJH1 03/07/07 0951 615304 KSDI 03/09/07 1712 615295 AXD2 03/07/07 1842 615132 0.00471

+/-0.018 0.0144

+/-0.018 1.38

+/-1.27 1.01

+/-1.27 47

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

951 4-0000-009F 181810008 Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Liquid Scintillation Analysis Liquid Scint 014, Solid All, FSS Carbon-14 U

0.0114

+1-0.0943 0.0789 +/-0.0943 0.162 pCilg AXD2 03/08/07 0518 615134 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-6.81

+/-33.1 22.8

+/-33.1 47.9 pCi/g MXP1 03/09/07 0351 615129 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-2.18

+/-8.52 7.26

+/-8.52 15.3 pCi/g MXP1 03/10/07 1803 616259 Liquid Scint T099, Solid-ALL FSS Technetium-99 U

-0.0992

+/-0.225 0.191

+/-0.225 0.388 pCi/g MXPI 03/11/07 2107 615131 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-II-RC Modified 3

DOE EML HASL-300, Pu-l I1-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-I, Modified 9

DOE RESL Ni-l, Modified 10 DOE RESL Ni-I, Modified 11I DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Alphaspec Am24l, Cm, Solid ALL Alphaspec Am24l, Cm, Solid ALL Alphaspec Pu, Solid-ALL ESS Alphaspec Pu, Solid-ALL ESS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Pu241, Solid-ALL FS 87 87 76 76 89 89 (15%-I125%)

(15%-125%)

(15 %-125%)

(15 %-125%)

(25%-1 25%)

(25%-I125%)

48

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

951 4-0000-009F 181810008 Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK0OI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Strontium Carrier Strontium Carrier Iron-59 Tracer Iron-59 Tracer Nickel Carrier Nickel Carrier Technetium-99m Tracer Technetium-99m Tracer GFPC, SOO0, solid-ALL ESS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Fe55, Solid-ALL ES Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL ES Liquid Scint Tc99, Solid-ALL ES Liquid Scint Tc99, Solid-ALL ES 89 89 65 65 88 88 83 83 (25%-I125%)

(25%-I 25%)

(15%-I 25%)

(15 %-125%)

(25%-I 25%)

(25%-I125%)

(15%-I125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncer-tain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

95 14-0000-01OF 181810009 TS 28-FEB-07 06-MAR-07 Client 5.11%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Alpha Spec Analysis Alp/mspec Am24J, Cm, Solid ALL FSS Americium-241 U

-0.125 Curium-242 U

-0.0359 Curium-243/244 U

0.0921 Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.125 Plutonium-239/240 U

0.00929 Liquid Scint Pu24J, Solid-ALL FSS Plutonium-241 U

2.47 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.347 Americium-241 U

0.0265 Bismuth-212 0.270 Bismuth-214 0.319 Cesium-] 34 U

0.0067 Cesium-137 U

0.0141 Cobalt-60 U

0.0131 Europium-152 U

0.0197 Europium-154 U

0.00546 Europium-ISS U

-0.0119 Lead-212 0.386 Lead-214 0.425 Manganese-54 U

0.0153 Niobium-94 U

0.00235 Potassium-40 9.63 Radium-226 0.319 Silver-i 08m U

0.00375 Thallium-208 0.119 Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Strontium-90 U -0.00234 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCig Tritium U

1.03

+/-0. 139

+/-0.0924

+/-0.211 0.162 0.099 0.148

+/-0.140

.+/-0.0925

+/-0.211

+/-0.221 0.152

+/-0.221

+/-0.0704 0.0516 +/-0.0705

+/-13.5 11.2

+/-13.5

+/-0.111 i-/-0.0539

+/-0.191

+/-0.0591

+/-0.0165

+/-0.0149

+/-0.0146

+/-0.0602

+/-0.0445

+/-0.0447

+/-0.0477

+/-0.0659

+/-0.0219

+/-0.0206

+/-0.828

+/-0.0591

+/-0.0122

+/-0.0318 0.0395 0.0449 0.0855 0.0227 0.0144 0.0136 0.01 35 0.0325 0.0388 0.0395 0.0203 0.0214 0.0108 0.0113 0.106 0.0227 0.0108 0.0116

+/-0.111

+/-0.0539

+/-0.191

+/-0.0591

+/-0.0165

+/-0.0149

+/-0.0146

+/-0.0602

+/-0.0445

+/-0.0447

+/-0.0477

+/-0.0659

+/-0.021 9

+/-0.0206

+/-0.828

+/-0.05 91

+/-0.01 22

+/-0.0318 0.427 0.304 0.398 0.394 0.193 23.5 0.079 0.0898 0.171 0.0454 0.0288 0.0272 0.027 0.0649 0.0776 0.079 0.0406 0.0427 0.02 17 0.0226 0.213 0.0454 0.02 16 0.0232 0.0334 2.03 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g GXRI 03/07/07 1533 615126 GXRI 03/07/07 1533 615127 GXRI 03/09/07 1538 615128 MJHI 03/07/07 0952 615304 KSDI 03/09/07 1712 615295 AXD2 03/07/07 1945 615132

+/-0.0167 0.0143 +/-0.0167

+/-1.20 0.967

+/-1.20 50

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

9514-0000-010OF 181810009 Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Liquid Scintillation Analysis Liquid Scint 014, Solid All, FSS Carbon-14 U

0.053

+/-0.0949 0.0785 +/-0.0949 0.161 pCi/g AXD2 03/08/07 0620 615134 Liquid Scint FeSS, Solid-ALL FSS Iron-55 U

8.39

+/-39.7 26.8

+/-39.7 56.2 pCilg MXPI 03/09/07 0522 615129 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

3.49

+/-9.37 7.69

+/-9.37 16.2 pCifg MXPI 03/10/07 1819 616259 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

-0.0251

+/-0.244 0.205

+/-0.244 0.417 pCi/g MXP1 03/11/07 2154 615131 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300, Pu-I I -RC Modified 4

DOE EML HASL-300, Pu-I I1-RC Modified 5

EML HASL 300, 4.5.2.3 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-I, Modified 10 DOE RESL Ni-l, Modified 11I DOE RESL Ni-i, Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Alphaspec Am241, Cm, Solid ALL Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS 82 82 83 83 34 (15%-I125%)

(15%-125%)

(15%-I125%)

(15%-125%)

(25%-I125%)

51

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

9514-0000-01OF 181810009 Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Plutonium-242 Tracer Strontium Carrier Strontium Carrier Iron-59 Tracer Iron-59 Tracer Nickel Carrier Nickel Carrier Technetium-99m Tracer Technetium-99m Tracer Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 34 92 92 63 63 84 84 77 77 (25%-I 25%)

(25%-1 25%)

(25%-1 25%)

(15 %-125%)

(15%-125%)

(25%-I125%)

(25%-1 25%)

(15 %-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

52

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-011iF 181810010 TS 28-FEB-07 06-MAR-07 Client 7.06%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.641

+1-0.189 0.0548

+/-0.189 0.110 pCi/g MJHI 03/07/07 1054 615304 Americium-241 U

0.0162

+/-0.0951 0.0891 +/-0.0951 0.178 pCi/g Bismuth-212 0.570

+/-0.256 0.123

+/-0.256 0.246 pCi/g Bismuth-214 0.443

+/-0.0951 0.0324 +/-0.0951 0.0648 pCi/g Cesium-134 U

0.022

+/-0.0291 0.0237 +/-0.0291 0.0474 pCi/g Cesium-137 0.0448

+/-0.0302 0.0201 +/-0.0302 0.0403 pCi/g Cobalt-60 U

0.00817

+/-0.020 0.0177

+/-0.020 0.0353 pCi/g Europium-152 U

0.032

+/-0.0724 0.0468 +/-0.0724 0.0936 pCi/g Europium-154 U

0.0158

+/-0.0583 0.0507 +/-0.0583 0.101 pCi/g Europium-ISS U

0.00937

+/-0.062 0.0565

+/-0.062 0.113 pCi/g Lead-212 0.657

+/-0.0731 0.0273 +/-0.0731 0.0546 pCi/g Lead-214 0.584

+/-0.0978 0.034 +/-0.0978 0.0679 pCi/g Manganese-54 UI 0.00

+/-0.0225 0.0179 +/-0.0225 0.0359 pCi/g Niobium-94 U 0.000765

+/-0.0191 0.0162 +/-0.0191 0.0324 pCi/g Potassium-40 UI 0.00

+/-0.842 0.807

+/-0.842 1.61 pCi/g Radium-226 0.443

+/-0.0951 0.0324 +/-0.0951 0.0648 pCi/g Silver-108m U -0.00633

+/-0.018 0.0154

+/-0.018 0.0308 pCi/g Thallium-208 0.201

+/-0.0412 0.0199 +/-0.0412 0.0398 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontiumn-90 U

0.00949

+/-0.0192 0.0147 +/-0.0192 0.0343 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 53

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project Soils PO# 002332 Client Sample ID:

95 14-0000-011iF Project:

YANK01204 Sample ID:

181810010 Client ID:

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 89 (25%-I 25%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 89 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

54

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

9514-0000-012F Project:

YANK01204 Sample ID:

181810011 Client ID:

YANKOOI Matrix:

TS Vol. Recv.:

Collect Date:

28-FEB-07 Receive Date:

06-MAR-07 Collector:

Client Moisture:

5.73%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.581

+/-0.151 0.0554

+/-0.151 0.111 pCi/g MJHI 03/07/07 1054 615304 Americium-241 U

0.0602

+/-0.0579 0.0507 +1-0.0579 0.101 pCi/g Bismuth-212 0.325

+/-0.245 0.126

+/-0.245 0.251 pCi/g Bismuth-214 0.378

+/-0.0826 0.0302 +/-0.0826 0.0603 pCi/g Cesium-134 UI 0.00

+/-0.0242 0.0195 +/-0.0242 0.0389 pCi/g Cesium-] 37 U

0.0229

+/-0.0201 0.0185 +/-0.0201 0.037 pCi/g Cobalt-60 U

0.021

+/-0.0284 0.0166 +/-0.0284 0.0332 pCi/g Europium-152 U

0.0341

+/-0.0651 0.0429 +/-0.0651 0.0857 pCi/g Europium-154 U

0.00763

+/-0.0619 0.0457 +/-0.0619 0.0914 pCi/g Europium-ISS U

0.0364

+/-0.048 0.0454

+/-0.048 0.0907 pCi/g Lead-212 0.5 19

+/-0.0639 0.0241 +/-0.0639 0.0482 pCi/g Lead-214 0.500

+/-0.0863 0.0302 +/-0.0863 0.0603 pCi/g Manganese-54 U

0.0186

+/-0.0252 0.0151

+/-0.0252 0.0303 pCi/g Niobium-94 U

0.0197

+/-0.0181 0.0166 +/-0.0181 0.0331 pCi/g Potassium-40 9.46

+/-0.899 0.136

+/-0.899 0.272 pCi/g Radium-226 0.378

+/-0.0826 0.0302 +/-0.0826 0.0603 pCi/g Silver-108m U -0.00366

+/-0.0156 0.0136 +/-0.0156 0.0272 pCi/g Thallium-208 0.180

+/-0.0454 0.0131 +/-0.0454 0.0261 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00925

+/-0.0193 0.0174 +/-0.0193 0.040 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

~~EML HASL 300 4952 3 2

2 EPA 905.0 Modified 55

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-012F Project:

YANK01204 Sample ID:

181810011 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch A%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 83 (25%-I125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 83 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

13D Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD, of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

951 4-0000-013F 181810012 TS 28-FEB-07 06-MAR-07 Client 11.3%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKO0l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.605

+/-0.158 0.0626

+/-0.158 0.125 pCi/g MJHI 03/07/07 1055 615304 Americium-241 U

0.00127

+/-0.0436 0.0266 +/-0.0436 0.0532 pCi/g Bismuth-212 UI 0.00

+/-0.189 0.181

+/-0.189 0.362 pCi/g Bismuth-214 0.582

+1-0.0948 0.0333 +/-0.0948 0.0666 pCi/g Cesium-134 UI 0.00

+/-0.0346 0.0209 +/-0.0346 0.0417 pCi/g Cesium-1 37 U -0.00925

+/-0.0226 0.0183 +/-0.0226 0.0366 pCilg Cobalt-60 U

-0.013

+1-0.0231 0.0182 +1-0.0231 0.0363 pCi/g Europium-152 U

0.00425

+/-0.0583 0.0435 +/-0.0583 0.087 pCi/g Europium-154 U

0.0429

+/-0.0673 0.0568 +/-0.0673 0.114 pCi/g Europium-155 U

0.0655

+/-0.0822 0.041 +/-0.0822 0.082 pCi/g Lead-212 0.684

+/-0.0858 0.0235 +/-0.0858 0.047 pCi/g Lead-214 0.617

+/-0.0939 0.029 +/-0.0939 0.0579 pCi/g Manganese-54 U

0.00743

+/-0.0191 0.0173 +/-0.0191 0.0345 pCilg Niobium-94 U

0.00364

+/-0.0199 0.0172 +/-0.0199 0.0344 pCi/g Potassium-40 9.55

+/-1.04 0.129

+1-1.04 0.259 pCi/g Radium-226 0.582

+/-0.0948 0.0333 +/-0.0948 0.0666 pCi/g Silver-108m U

0.00331

+/-0.0186 0.0146 +/-0.0186 0.0292 pCi/g Thallium-208 0.189

+/-0.0435 0.0154 +/-0.0435 0.0307 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.00276

+/-0.0183 0.0149 +/-0.0183 0.0347 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 57

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

95 14-0000-013F Project:

YANK01204 SamplelID:

181810012 Client ID:

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, SOO0, solid-ALL FSS 85 (25%-I125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 85 (25%-I125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCJMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPIJ of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of A~nalvsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-01 4F 181810013 TS 28-FEB-07 06-MAR-07 Client 17.8%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.827

+/-0.235 0.106

+1-0.235 0.211 pCi/g MJ`HI 03/07/07 1057 615304 Americium-241 U

0.0668

+/-0.0566 0.0465 +/-0.0566 0.0929 pCi/g Bismuth-212 UI 0.00

+/-0.567 0.242

+/-0.567 0.484 pCilg Bismuth-214 0.476

+/-0.139 0.0531

+/-0.139 0.106 pCilg Cesium-134 U

0.0724

+/-0.0509 0.0368 +/-0.0509 0.0735 pCilg Cesiumn-137 0.0954

+/-0.0614 0.0305 +/-0.0614 0.0609 pCi/g Cobalt-60 U

0.025

+/-0.0386 0.0339 +/-0.0386 0.0677 pCilg Europium-152 U

-0.0264

+/-0.0976 0.0725 +/-0.0976 0.145 pCi/g Europiumn-154 U

-0.0112

+/-0.114 0.0941

+/-0.1 14 0.188 pCi/g Europiumn-ISS U

0.0866

+/-0.0815 0.0732 +/-0.0815 0.146 pCi/g Lead-212 0.843

+/-0.111 0.0396

+/-0.111 0.0791 pCilg Lead-214 0.662

+/-0.131 0.0522

+/-0.131 0.104 pCi/g Manganese-54 U -0.00194

+/-0.0357 0.0306 +/-0.0357 0.0611 pCi/g Niobium-94 U

0.00229

+/-0.0355 0.0297 +/-0.0355 0.0593 pCi/g Potassium-40 13.3

+/-1.39 0.254

+/-1.39 0.508 pCi/g Radium-226 0.476

+/-0.139 0.0531

+/-0.139 0.106 pCi/g Silver-108m U -0.0174

+/-0.0299 0.0249 +/-0.0299 0.0497 pCilg Thallium-208 0.230

+/-0.0699 0.0274 +/-0.0699 0.0548 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.00902

+/-0.0173 0.0131 +/-0.0173 0.031 pCi/g KSDI 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 59

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-014F Project:

YANK0 1204 Sample ID:

181810013 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCJMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

60

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificate ofAnalvsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

951l4-0000-014FS 181810014 TS 28-FEB-07 06-MAR-07 Client 17.5%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKO0 I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.836

+/-0.219 0.0773

+/-0.219 0.155 pCi/g MJH1 03/07/07 1211 615304 Americium-241 U

0.0627

+/-0.116 0.0933

+/-0.116 0.187 pCi/g Bismuth-212 UI 0.00

+/-0.420 0.157

+/-0.420 0.313 pCi/g Bismuth-214 0.510

+/-0.115 0.0422

+/-0.115 0.0844 pCi/g Cesium-I 34 U

0.0361

+/-0.0359 0.0263 +/-0.0359 0.0525 pCi/g Cesium-137 0.113

+/-0.0397 0.0254 +/-0.0397 0.0508 pCi/g Cobalt-60 U

0.00051

+/-0.0263 0.0219 +/-0.0263 0.0437 pCi/g Europium-152 U -0.00684

+/-0.0748 0.0561 +/-0.0748 0.112 pCi/g Europium-154 U

0.00964

+/-0.082 0.0691

+1-0.082 0.138 pCi/g Europium-ISS U

0.0724

+/-0.0783 0.0657 +/-0.0783 0.131 pCi/g Lead-212 0.771

+/-0.0936 0.0308 +/-0.0936 0.0616 pCi/g Lead-214 0.682

+/-0.118 0.0409

+/-0.118 0.0817 pCi/g Manganese-54 U

-0.0196

+/-0.0252 0.0203 +/-0.0252 0.0406 pCi/g Niobium-94 U

-0.0215

+/-0.0236 0.0181 +/-0.0236 0.0361 pCi/g Potassium-40 12.2

+/-1.24 0.191

+/-1.24 0.381 pCi/g Radium-226 0.510

+/-0.115 0.0422

+/-0.115 0.0844 pCi/g Silver-108m U

-0.0136

+/-0.0232 0.0191

+/-0.0232 0.0382 pCi/g Thallium-208 0.272

+/-0.048 0.01 92

+/-0.048 0.0383 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0293

+/-0.023 0.0155

+/-0.023 0.036 pCi/g KSD1 03/09/07 1712 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limidts 61

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-014FS Project:

YANK01204 Sample ID:

181810014 Client ID:

YANKO0 I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 90 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 90 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-0 15F 181810015 TS 28-FEB-07 06-MAR-07 Client 9.31%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.737

+/-0.206 0.0754

+/-0.206 0.151 pCi/g MJHI 03/07/07 1254 615304 Americium-241 U

-0.0715

+/-0.112 0.0895

+/-0.112 0.179 pCi/g Bismuth-212 0.628

+/-0.366 0.143

+/-0.366 0.287 pCi/g Bismuth-214 0.505

+1-0.105 0.0386

+1-0.105 0.0771 pCi/g Cesium-] 34 UI 0.00

+/-0.0619 0.0231 +/-0.0619 0.0461 pCi/g Cesium-137 U

0.00326

+/-0.0234 0.0205 +/-0.0234 0.041 pCi/g Cobalt-60 U

0.0204

+/-0.0273 0.025 +/-0.0273 0.0499 pCi/g Europium-152 U

-0.0282

+/-0.074 0.0507

+/-0.074 0.101 pCi/g Europium-154 U

0.0172

+/-0.0854 0.0644 +/-0.0854 0.129 pCi/g Europium-ISS U

0.094

+/-0.0939 0.0553 +/-0.0939 0.111 pCi/g Lead-212 0.709

+/-0.0832 0.0313 +/-0.0832 0.0626 pCi/g Lead-214 0.623

+/-0.105 0.0372

+1-0.105 0.0743 pCi/g Manganese-54 U

0.00539

+/-0.0266 0.0229 +/-0.0266 0.0458 pCi/g Niobium-94 U -0.00195

+/-0.021 0.018

+/-0.021 0.0359 pCi/g Potassium-40 11.9

+/-1.24 0.173

+/-1.24 0.346 pCi/g Radium-226 0.505

+/-0.105 0.0386

+/-0.105 0.0771 pCi/g Silver-i 08mn U2.360E-05

+/-0.0206 0.0176 +/-0.0206 0.0351 pCi/g Thallium-208 0.247

+/-0.0542 0.0202 +/-0.0542 0.0403 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.017

+/-0.0217 0.0157 +/-0.0217 0.037 pCi/g KSD1 03/09/07 1713 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limnits 63

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-015F Project:

YANK01204 Sample ID:

181810015 Client ID:

YANKOQI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 12, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-01 5FS 181810016 TS 28-FEB-07 06-MAR-07 Client 9.2%

Project:

Client ID:

Vol. Recv.:

YANKO01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.871

+/-0.173 0.0683

+/-0.173 0.137 pCi/g MIHI 03/07/07 1255 615304 Americium-241 U

0.0784

+/-0.101 0.086

+/-0.101 0.172 pCi/g Bismuth-212 0.440

+/-0.243 0.127

+/-0.243 0.254 pCi/g Bismuth-214 0.554

+/-0.0987 0.033 +/-0.0987 0.0659 pCi/g Cesium-134 U

0.0326

+/-0.0348 0.0233 +/-0.0348 0.0465 pCi/g Cesium-I 37 U

0.00412

+/-0.0228 0.0196 +/-0.0228 0.0393 pCi/g Cobalt-60 U

0.020

+/-0.0224 0.0206 +/-0.0224 0.0411 pCi/g Europium-152 U

-0.0215

+/-0.077 0.0457

+/-0.077 0.0913 pCi/g Europium-154 U

0.0183

+/-0.0709 0.0612 +/-0.0709 0.122 pCi/g Europium-155 U

0.0261

+/-0.0626 0.0579 +/-0.0626 0.116 pCi/g Lead-212 0.727

+/-0.0783 0.0286 +/-0.0783 0.0572 pCi/g Lead-214 0.554

+/-0.0919 0.0333 +/-0.0919 0.0666 pCi/g Manganese-54 UI 0.00

+/-0.027 0.01 69

+/-0.027 0.0337 pCi/g Niobium-94 U 0.000212

+/-0.021 0.0178

+/-0.021 0.0356 pCi/g Potassium-40 12.2

+/-1.17 0.150

+/-1.17 0.301 pCi/g Radium-226 0.554

+/-0.0987 0.033 +/-0.0987 0.0659 pCi/g Silver-108m U

0.00653

+/-0.0183 0.0165 +/-0.0183 0.0329 pCi/g Thallium-208 0.213

+/-0.0483 0.0175 +/-0.0483 0.035 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.000579

+/-0.0193 0.0161 +/-0.0193 0.0372 pCi/g KSD1 03/09/07 1713 615295 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 03/06/07 1031 615118 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 65

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 12, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Client Sample ID:

95 14-0000-015FS Proiect:

YANK01204 Sample ID:

181810016 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU NMA units DF Analyst Date Time Batch A%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 83 (25%-i125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 83 (25%-I 25%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

66

r_-

.1 QUALITY CONTROL DATA 67

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com (QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: March 12, 2007 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

181810 Parmname NOM Samu~le Oual QC Units RPD%

REC%

Range AnIst Date Time Rad Alpha Spec Batch 615126 Americium-24 I Curium-242 Curium-243/244 QC 120 1290640 Americium-24 1 Curium-242 Curium-243/244 QCI 201290637 Americium-24 I 181810008 DUP u

-0.0808 Uncert:

+/-0.143 TPU:

+/-0.144 u

0.00253 Uncert:

+/-0.0972 TPU:

+/-0.0972 u

0.0098 Uncert:

+/-0.188 TPU:

+/-0.188 LCS 12.9 Uncert:

TPU:

Uncert:

TPU:

15.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0395

+/-0.140

+/-0.140 U

0.0387

+/-0.131

+/-0.131 U

-0.043

+/-0.173

+/-0.173 14.3

+/-1.30

+/-2.30 U

-0.0296

+/-0.029

+/-0.0293 15.6

+/-1.36

+/-2.48 U

-0.0332

+/-0.079

+/-0.0791 U

-0.0381

+/-0.0334

+/-0.0338 U

-0.133

+/-0.135

+/-0.136 pCilg 69 pCilg 175 pCi/g 318 (0% - 100%)

(0%- 100%)

(0% - 100%) ZIXR I MB 03/07/07 15:33 Curium-242 pCilg pCi/g pCilg pCilg pCi/g pCi/g pCi/g PCilg pCi/g 101 (75%-125%)

111 (75%-125%)

03/07/07 15:33 03/07/07 15:33 Curium-243/244 QC1 201290639 Americium-24 I 181810008 MS Uncert:

TPU:

13.5 Uncert:

TPU:

Uncert:

TPU:

16.2 Uncert:

TPU:

U

-0.0808

+/-0.143

+/-0.144 U

0.00253

+/-0.0972

+/-0.0972 U

0.0098

+/-0.188

+/-0.188 Curium-242 U

14.8

+/-1.45

+/-2.5 2 0.0105

+/-0.0799

+/-0.080 15.8

+/-1.49

+/-2.65 110 (75%-125%)

Curium-243/244 98 (75%-125%)

Batch 615127 QC1201290642 181810008 DUP Plutonium-238 U

-0.0422 U

0.0565 pCi/g 1380 (0% - 100%) GXRI1 03/07/07 15:33 68

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 2 of 9 Parmname Rad Alpha Spec Batch 615127 NOM Sample Qual OC Units RPD%

REC%

Ranile AnIst Date Time Plutonium-239/240 QC 1201290644 LCS Plutonium-238 Plutonium-239/240 QC 1201290641 MB Plutonium-238 Plutonium-239/240 QC1201290643 181810008 MIS Plutonium-238 Uncert:

+/-0.0879 TPU:

+/-0.0881 U

0.111 Uncert:

+/-0.147 TPU:

+/-0. 147 Uncert:

TPU:

12.8 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0422 Uncert:

+/-0.0879 TPU:

+/-0.0881 13.5 U

0.111 Uncert:

+/-0.147 TPU:

+/-0.147 U

-0.807 Uncert:

+/-7.20 TPU:

+/-7.20 U

+/-0.185

+/-0.185 0.134

+/-0.164

+/-0.164 pCi/g 19 (0% - 100%)

(75%-125%)

U

-0.0368

+/-0.0766

+/-0.0768 13.3

+/-1.28

+/-2.02 U

0.156

+/-0.173

+/-0.174 U

0.00258

+/-0.0992

+/-0.0992 U

0.086

+/-0.167

+/-0. 167 14.2

+/-1.34

+/-2.13 U

-1.01

+/-6.93

+/-6.93 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 03/07/07 15:33 104 (75%-125%)

03/07/07 15:33 (75%- 125%)

Plutonium-239/240 105 (75%-125%)

Batch 615128 QC1201290646 181810008 DUP Plutonium-24 I QC1201290648 LCS Plutonium-24 I QC 1201290645 MB Plutonium-24 I QC1201290647 181810008 MS Plumtniiim-24 1 pCi/g 0

(0% - 100%) GXRI 139 Uncert:

TPU:

Uncert:

TPU:

142 U

Uncert:

TPU:

134

+/- 13.3

+/-18.7 U

-0.93

+/-8.30

+/-8.30 pCi/g pCi/g pCi/g 96 (75%-125%)

03/09/07 13:11 03/08/07 21:56 03/09/07 12:55 03/08/07 21:40

-0.807

+/-7.20

+/-7.20 142

+/-13.9

+/-19.7 100 (75%-125%)

Rad Gamma Spec Batch 615304 QC1201291075 181810001 DUP Actinium-228 0.430

+/-0.183 Uncert:

0.673

+/-0. 180

+/-0.180 pCi/g 44 (0% -100%) MJH1 03/07/07 12:56 69

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 3 of 9 Parnmame Rad Gamma Spec Batch 615304 NOM Sample Qual OC Units RPD%

REC%

Ranae AnIst Date Time Americium-24 1 Bismuth-2 12 Bismuth-2 14 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.183 u

-0.0148 Uncert:

+/-0.0972 TPU:

+/-0.0972 0.506 Uncert:

+/-0.200 TPU:

+/-0.200 0.459 Uncert:

+/-0.0994 TPU:

+/-0.0994 u

0.0487 Uncert:

+/-0.0404 TPU:

+/-0.0404 0.0422 Uncert:

+/-0.0376 TPU:

+/-0.0376 U

0.0117 Uncert:

+/-0.0245 TPU:

+/-0.0245 U

0.0413 Uncert:

+/-0.0666 TPU:

+/-0.0666 U

0.0955 Uncert:

+/-0.077 TPU:

+/-0.077 U

-0.00556 Uncert:

+/-0.0613 TPU:

+/-0.0613 0.5 18 Uncert:

+/-0.0715 TPU:

+/-0.07 15 0.436 Uncert:

+1-0.0997 TPU:

+/-0.0997 U

-0.000608 Uncert:

+/-0.0226 TPU:

+/-0.0226 U

0.00747 Uncert:

+/-0.0 197 TPU:

+1-0.0197 8.60 Uncert:

+/-1.04 TPU:

+1-1.04 0.459 Uncert:

+/-0.0994 TPU:

+1-0.0994 U

-0.00544 Uncert:

+/-0.0206 U

0.020

+1-0.0693

+/-0.0693 0.381

+/-0.251

+/-0.251 0.469

+/-0.0805

+/-0.0805 U

0.0311

+/-0.0267

+/-0.0267 0.06 13

+/-0.027

+/-0.027 U

0.0123

+/-0.0228

+/-0.0228 U

0.0226

+/-0.0542

+/-0.0542 U

0.0187

+/-0.0645

+/-0.0645 U

0.0223

+/-0.0654

+/-0.0654 0.504

+/-0.064

+/-0.064 0.484

+/-0.0802

+/-0.0802 U

-0.00201

+/-0.0203

+/-0.0203 U

-0.00494

+/-0.0185

+/-0.0185 9.95

+/-0.985

+/-0.985 0.469

+/-0.0805

+/-0.0805 U

-0.00757

+/-0.0 163 pCi/g 1340 pCi/g 28 pCi/g 2

pCi/g 44 pCi/g 37 pCi/g 5

pCi/g 58 pCi/g 135 pCi/g 333 pCi/g 3

pCi/g 10 (0% - 100%)

(0%- 100%)

(0% - 100%)

(0% -100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% -20%)

(0% - 100%)

(0% - 100%)

(0% -100%)

(0% -20%)

(0% - 100%)

(0% - 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I 08m pCi/g 107 pCi/g 981 pCi/g 15 pCi/g 2

pCi/g 33 70

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Q)C Summary Workorder:

181810 Page 4 of 9 Parmname NOM Sample Qua]

QC Units RPD %

REC%

Range Anist Date Time Rad Gamma Spec Batch 615304 Thallium-208 TPU:

+/-0.0206 0.189 Uncert:

+/-0.0471 TPU:

+/-0.0471

+/-0.0163 0.150

+/-0.0352

+/-0.0352 pCi/g 23 (0% -100%)

Actinium-228 Americium-24 1 Bismuth-2 12 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 LCS Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.46 Uncert:

TPU:

13.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.0542

+/-0.587

+/-0.587 26.2

+/-3.14

+/-3.14 U

0.0753

+/-1.04

+/-1.04 U

-0.0906

+/-0.235

+/-0.235 U

0.0118

+/-0.149

+/-0.149 9.68

+/-0.857

+/-0.857 13.8

+/-1.09

+/-1.09 U

-0.206

+/-0.301

+/-0.30 1 U

0.177

+/-0.251

+/-0.25 1 U

-0.0562

+/-0.3 10

+/-0.310 U

-0.0184

+/-0.1 64

+/0164 U

0.0688

+/-0.227

+/-0.227 U

-0.0315

+/-0. 139

+/-0. 139 U

-0.0873

+/-0.118

+/-0.118 U

-0.369 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 03/07/07 09:52 112 (75%-125%)

102 (75%-125%)

102 (75%-125%)

Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 71

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 5 of 9 REC%

Ranpe Anist Date Time Parmname NOM SaMDle OuaI OC Units RPD %

Parnmame Rad Gamma Spec Batch 615304 Radium-226 Silver-108m Thallium-208 Actinium-228 Americium-24 1 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.778

+/-0.778 U

-0.0906

+/-0. 235

+/-0.235 U

-0.00105

+/-0.120

+/-0.120 U

0.0752

+/-0.126

+/-0.126 U

-0.0606

+/-0.0632

+/-0.0632 U

-0.0174

+1-0.0509

+/-0.0509 U

0.0284

+/-0.116

+1-0.116 U

0.0195

+/-0.0542

+1-0.0542 U

0.0192

+1-0.0196

+/-0.0196 U

0.00349

+/-0.0 152

+/-0.0152 U

-0.00929

+1-0.0136

+/-0.0136 U

-0.00507

+/-0.0354

+/-0.0354 U

0.00351

+1-0.0335

+/-0.0335 U

-0.006

+/-0.0314

+/-0.0314 U

0.0137

+/-0.0323

+1-0.0323 U

0.0169

+/-0.0437

+/-0.0437 pCi/g pCilg pCi/g pCilg pCi/g pCilg pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g 03/07/07 12:55 (75%-I125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 72

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 6 of 9 Parnmame NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time Rad Gamma Spec Batch 615304 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I 08m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.00921

+/-0.013

+/-0.013 U

-0.000898

+/-0.0132

+/-0.0132 U

-0.177

+/-0.156

+/-0.156 U

0.0195

+/-0.0542

+/-0.0542 U

0.00316

+/-0.0118

+/-0.0118 U

0.0126

+1-0.0214

+/-0.0214 pCilg pCilg pCilg pCilg pCilg pCilg 615295 QC1201291054 181810010 DUP Strontium-90 QC1201291056 LCS Strontium-90 QC1201291053 MB Strontium-90 QC1201291055 181810010 MIS Strontium-90 Rad Liquid Scintillation Batch 615129 QC1201290650 181810008 DUP Iron-55 U

0.00949 Uncert:

+/-0.0 192 TPU:

+/-0.0192 U

0.00105

+/-0.0227

+/-0.0227 1.46

+/-0.106

+/-0.115 pCilg 0

(0% - 100%) KSD1 1.52 Uncert:

TPU:

Uncert:

TPU:

1.66 U

Uncert:

TPU:

U 0.00807

+/-0.0173

+/-0.0173 pCi/g pCilg pCilg 96 (75%-125%)

92 (75%-125%)

03/09/07 17:13 03/09/07 17:14 03/09/07 17:13 03/09/07 17:14 0.00949

+/-0.0192

+/-0.0192 1.53

+/-0.118

+/-0.127 U

-6.81 Uncert:

+/-33.1 TPU:

+/-33.1 U

15.4

+/-41.4

+/-41.4 pCi/g 0

(0% - 100%) VIXPI QC 1201290652 LCS Iron-55 QC1201290649 MB Iron-55 1420 Uncert:

TPU:

1390

+/-81.5

+/-121 pCi/g 98 (75%-125%)

03/09/07 05:55 03/09/07 06:27 03/09/07 05:38 U

24.1 pCi/g 73

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com (OC Summary Workorder:

181810 Parmname Rad Liquid Scintillation Batch 615129 Page 7 of 9 REC %

Ran~e AnIst Date Time NOM SamDle OuaI OC Units RPD%

Uncert:

TPU:

QC1201290651 181810008 MIS Iron-S55

+/-43.5

+/-43.6 1540

+/-88.9

+/-134 1570 U

Uncert:

TPU:

-6.81

+/-33.1

+/-33.1 pCi/g 98 (75%-125%)

03/09/07 06:11 Batch 615131 QC1201290658 181810008 DUP Technetium-99 U

-0.0992 Uncert:

+/-0.225 TPU:

+/-0.225 U

0.00

+/-0.217

+/-0.217 pCi/g 0

(0% - 100%) \\4XP1 QC1201290660 LCS Technetium-99 QC 1201290657 MB Technetium-99 19.7 Uncert:

TPU:

Uncert:

TPU:

19.7 U

Uncert:

TPU:

19.6

+/-0.438

+1-0.650 U

-0.0234

+/-0.202

+/-0.202 pCi/g pCi/g pCi/g 100 (75%-125%)

03/11/07 23:28 03/12/07 01:03 03/11/07 22:41 03/12/07 00:16 QC1201290659 181810008 MS Technetium-99

-0.0992

+/-0.225

+/-0.225 Batch 615132 QC1201290666 181810008 DUP Tritium Q0I201290668 LCS Tritium QC 1201290665 M B Tritium Q01201290667 181810008 MIS Tritium U

1.38 Uncert:

+/-1.27 TPU:

+/-1.27 19.0

+/-0.496

+/-0.682 2.11

+/- 1.26

+/-1.26 13.3

+/-3.09

+/-3.10 96 (75%-125%)

pCi/g 42 (0% - 100%) k\\XD2 11.1 Uncert:

TPU:

Uncert:

TPU:

11.8 U

Uncert:

TPU:

U 0.610

+/-1.17

+/-1.17 pCi/g pCi/g pCi/g 119 (75%-125%)

03/07/07 2 1:50 03/07/07 23:36 03/07/07 20:47 03/07/07 22:52 1.38

+/-1.27

+/-1.27 Raqtch 615134 QC1201290674 181810008 DUP Carbon-14 QCI1201290676 LCS Carbon-14 U

0.0114 Uncert:

+/-0.0943 TPU:

+/-0.0943 U

14.9

+/-2.10

+/-2.11 0.00918

+/-0.0874

+/-0.0874 6.68

+/-0.251

+/-0.271 125 (75%-125%)

pCi/g 0

(0% - 100%) t\\XD2 03/08/07 08:25 03/08/07 10:29 6.75 Uncert:

TPU:

pCi/g 99 (75%-125%)

74

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 8 of 9 QC Units RPD%

REC%

Range Anist Parmname Rad Liquid Scintillation Batch 615134 NOM Samnie Oual Date Time NO Samnle Oual QC 1201290673 MB Carbon-14 Uncert:

TPU:

U 0.0548

+/-0.0893

+/-0.0893 pCi/g pCi/g 03/08/07 07:22 03/08/07 09:27 QC1201290675 181810008 MS Carbon-14 6.97 U

Uncert:

TPU:

0.0114

+/-0.0943

+/-0.0943 7.19

+/-0.205

+/-0.234 103 (75%-125%)

Batch 616259 QC1201293432 181810008 DUP Nickel-63 QC1201 293434 LCS Nickel-63 QC1201293431 MB Nickel-63 QC1201293433 181810008 MS Nickel-63 U

-2.18 Uncert:

+/-8.52 TPU:

+/-8.52 U

4.30

+/-8.68

+/-8.68 pCi/g 0

(0% - 100%) VIXPI 578 Uncert:

TPU:

Uncert:

TPU:

585 U

Uncert:

TPU:

503

+/-23.3

+/-29.6 U

2.60

+/-8.30

+/-8.30 pCi/g pCi/g pCi/g 87 (75%-125%)

82 (75%-125%)

03/10/07 18:51 03/10/07 19:24 03/10/07 18:35 03/10/07 19:07

-2.18

+/-8.52

+/-8.52 482

+/-23.2

+/-29.1 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol -condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound 75

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181810 Page 9 of 9 Parmnamne NOM Sample Qual QC Units RPD %

REC%

Range Anist Date Time Y

A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

76

TABLE OF CONTENTS General Narrative............................................

1 Chain of Custody and Supporting Documentation........ 5 Data Review Qualifier Definitions........................... 9 Radiological Analysis........................................ 11 Sample Data Summary................................... 18 Quality Control Data......................................

30

General Narrative Page 1 of 39

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 184029 SDG: MSR#07-0144 April 16, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on April 12, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 184029001 951 4-0000-008F 184029002 9514-0000-01 6J 184029003 9514-0000-01 7J 184029004 9514-0000-01 8J 184029005 9514-0000-01 9B Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Reguest Five samples were analyzed for FSSGAM and Strontium 90.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

GEL Laboratories Mage 2Pp9aP712 Chafleston, SC 29417 2040 Savge Road Charfssmn.SC 29407 P 843.556.8171 F 84&.766.1178 wwglcm www.gol.com

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl ýones Project Manager GEL Laboratories Pfge 3 Wp59T712 Chadfeston, SC 29417 2040OSavage Road Cheilestm.nSC 29407 P843.555.8171 F5843.755.1178 w glcm www.gol.com

List of current GEL Certifications as of 16 April 2007 State

-ICertification Alaska IUST-062 Arizona IAZ0668 Arkansas88-065 1 CLIA 42DO904046 California 01151CA Colorado GenEngLabs Connecticut PH-01 69 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E871 56 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas NELAP TI 04704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 Page 4 of 39

Chain of Custody and Supporting Documentation Page 5 of 39

Health Physics Procedure Healh PhsicsProcdureGPP-GGGR-R5 104-003-Attachment B-CY-002 Connecticut Yankee Atomic Power Company Chain of Custody Form N.20-02 362 InJun Hollowx Road. East Hampton. CT 06424 N.20-02 860-267-2556 Pr.ec Nme Hddm ec DcomisinigAnalyses Requested Lab Use Only Contct Nrne&

Phne:Comments:

Jac M~arhy86-26-324Media Sample Container Jac M~arhy86-26-324Code Type Size-Analytical Lab (Name, City, State):

Code

&Type Geneal Eginerin LabratoiesCode 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)

Priority:EI 30D.DE 15 D. X7 D.<

Other:

0

<KLQ4I Sample Designation Date Time

_____Comment, Preservation Lab Sample ID 9514-0000-008F 4/10/07 1315 TS G

BP X

9514-0000-016J 4/10/07 1318 TS G

BP X

9514-0000-0171 4/10/07 1320 TS G

BP X

9514-0000-018J 4/10/07 1323 TS G

BP X

9514-O000-019B 4/10/07 1325 TS G

BP X

NOTES: P04#:002332 MSR #: 07-0 144 ZLTP QA i Radwaste QA LINon QA Samples Shipped Via:

internal Container N Fed Ex Temp.: _I3r Deg. C El UPS El Hand Custody Sealed?

Y I1/ N [E

1) Relinq~T~y Date/Time
2) Received By Date/Time ElOhrCustody Seal Intact?

Z1111 fI 0

ý;

-F---

Cl 5 1 Jc) q,3L te

3) Relinquished By J6ate/Time
4) Received By Date/Time Y_____V/____

N;J Bill of Lading 4

5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee

-Statement of Work for Analytical Lab Services

  • cY-Isc-sow-ooi Figure 1. -Sample Check-'in List.

Date/Time Received:.

SDG#:

1 (ALIc f4(

)q Work Order Number:.

A~L~9 i~qs o /g~e 3

7 12,?5. 5(v3 ia6 CA)-

c_)-6? 01,19, 9

00) 6 Shipping Cchitainer ID.,7c

~PS IL ~-959 SO(rCCX Chain of Custody#.Q crn? -C1L (NV7-0/

1.

Custody Seals. oii shipping container intact?...

.Yes te.4/No

2.

Custody Seals dated and. signed?

YesJ1

3.

Chain-of-Custodiy rcord pr~esent?

Yes [).~o iI

.4..

Cooler temperature

5.

Vermiculite/packing materials -is:We 1Dy4 6' Number of samples in shipping'container

~

1

7.

Sample holding times exc'eeded?

Yes[]No4,1-10.

Were any anomalies identi~fied in sample receipt?

Description of anomalies, (include sample numbers):

Yes[JNoj-Sample Custodian/LaboDratory:.

Telephoned to:______

0___O Dote:____

  • __By PageTof 39 1T

SAMPLE RECEIPT & REVIEW FORM 15-61, e,ýs PM use only Client:

Cam t+,, Li..

4)elk-L SDG/ARCOC/Work Order: 1~91q0?, 19`10o36, /rrqe31.

/ 9Y63Z~

Date Received:

d-)

)- 0 -7 PM(A) Reiiýensure non-conflo In terns are resolved prior to signing):

Received By:

7-S L

7 2=___________________

Sample Receipt Criteria t

0 Comments/Qualifiers (Required for Non-Conforming Items)

Z Z Shipping containers received Circle Applicable, seals broken damaged container leaking container other (describe) intact and sealed?

Samples requiring cold Circle Coolant #

ice bags blue ice dry ice none other describe) 2 preservation within (4 +/- 2 C)?

'~

-~

__Record preservation method.____________________________

3Chain of custody documents lincluded with shipment?____________________________

4Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe)

_ sealed?

5 Samples requiring chemical Samnple ID's. containers affected and ob~served pH:

preservation at proper pH?

I_____________________________

6 VOA vials free of headspace "I

Sample ID's and containers af.fect Ied:

6(defined as < 6mm bubble)?______________

jAre Encore containers present?V1 7 (If yes, immediately deliver to/

__VOA laboratory)___________________

8 Samples received within holding Id's and tests affected:

__time?_______________________________

9 Sample ID's on COC match ID's Sample ID's and containers affected:

__on bottles?____________________

10 Date & time on COG match date Sample ID's affected:

& time on bottles?____________________________

11Number of containers received Sample 113's affected:

match number indicated on COG?

12 COC form is properly signed in relinquished/received sections?

_________________1___________I____

14 Air Bill,Tracking #'s, &

9 j Ll C,

'Cc Ic 1

0 Additional Comments

-o T RSO RAD Receipt #

ma.

  • If > x2 area background is observed on samples identified as "non-Suspcte Haar Fn1rato J& regulated/non-radioactive", contact the Radiation Safety group for further Sinvestigation.

A l~adiotogicai Classitication(!

I Counts Observed*:-

B PCB Regulated?

V Shipped as DUI1 Hazardous C Material? If yes, contact Waste L111 Manager or ESH Manager.

D~eg d rei1g~noi.

zard Class Shipped:

PM (ori'MA) review of Hazard classification:

Iiil

'(

Dt:-(-0 I/

Initials Ulwf Date:

q11 2- / o?

Data Review Qualifier Definitions Page 9 of 39

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greeter than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MOL/TOL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

S-day ROD-The 2:1 depletion requirement was not met for this sample S

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is >10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories P'fige IOMc9fpW12 Clwlestcn, SC 29417 2040OSavge Road Chaflsstn,8SC29407 P843.555.171 F843.76&.1178 www.gsl.com

RADIOLOGICAL ANALYSIS Page 11 of 39

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 184029 Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep B~atch Number:

Sample ID 184029001 184029002 184029003 184029004 1201313865 1201313866 1201313867 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 624979 624889 Client ID 9514-0000-008F 9514-0000-016J 9514-0000-017J 9514-0000-01 8J Method Blank (MB) 184029004(9514-0000-018J) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Page 12 of 39

Designated QC The following sample was used for QC: 184029004 (95 14-0000-018J).

QC Information All of the QC samples met the required acceptance limits.

Technical information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep, or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance.

Americium-241 184029002 Bismuth-2 12 184029001 184029004 Cesium-134 184029003 Method/Analysis Information Page 13 of 39

Pro duct:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 184029005 1201315240 1201315241 1201315242 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 625519 624889 Client ID 9514-0000-019B Method Blank (MB) 184030001(9803-0000-001 F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 184030001 (9803-0000-OO1F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information Page 14 of 39

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier U'

Reason Analyte Data rejected due to low abundance.

Cesium-134 Sample 184029005 1201315241 Method/Analysis Information Product:

Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

GFPC, Sr9O, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 624917 624895 624889 Page 15 of 39

Sample ID 184029001 184029002 184029003 184029004 184029005 1201313721 1201313722 1201313723 1201313724 Client ID 951 4-0000-008F 9514-0000-016J 9514-0000-017J 9514-0000-018J 9514-0000-019B Method Blank (MB) 184029002(9514-0000-016J) Sample Duplicate (DUP) 184029002(9514-0000-016J) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.

Calib ration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 184029002 (95 14-0000-016J).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 184029001 (95 14-0000-008F) was recounted due to a negative result greater than three times the error.

Page 16 of 39

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Samples were dried and reweighed due to low matrix spike recovery.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

tqAAJ)1D q~l -~7 Page 17 of 39

SAMPLE DATA

SUMMARY

Page 18 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOlI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-0144 GEL Work Order: 184029 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 19 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 19, 2007 Client Sample ID:

9514-0000-008F Project:

YANK0 1204 Sample ID:

184029001 Client ID:

YANKOOI Matrix:

TS Vol. Recv.:

Collect Date:

10-APR-07 Receive Date:

12-APR-07 Collector:

Client Moisture:

4.93%

Parameter Qualifier Result Uncertainty LC TPU MDA units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.340

+/-0.133 0.0619

+/-0.133 0.124 pCi/g MJHI 04/16/07 1041 624979 Amnericium-241 U

0.0597

+/-0.0868 0.0748 +/-0.0868 0.149 pCi/g Bismuth-212 UI 0.00

+/-0.220 0.162

+/-0.220 0.324 pCi/g Bismuth-214 0.340

+/-0.0907 0.0343 +/-0.0907 0.0686 pCi/g Cesium-134 U

0.0278

+/-0.02 16 0.0206 +/-0.0216 0.0411 pCi/g Cesiumn-137 U -0.00173

+/-0.023 0.0165

+/-0.023 0.0331 pCi/g Cobalt-60 U-0.000512

+/-0.0252 0.0213 +/-0.0252 0.0425 pCi/g Europium-152 U

-0.0411

+/-0.0822 0.0448 +/-0.0822 0.0896 pCi/g Europium-154 U

0.0344

+/-0.0683 0.061

+/-0.0683 0.122 pCi/g Europium-I 55 U

0.0126

+/-0.0527 0.0483 +/-0.0527 0.0966 pCi/g Lead-212 0.413

+/-0.0655 0.0251 +/-0.0655 0.0501 pCi/g Lead-214 0.336

+/-0.076 0.0326

+/-0.076 0.0652 pCi/g Manganese-54 U

0.0217

+/-0.0218 0.0201 +/-0.0218 0.0402 pCi/g Niobium-94 U

0.015

+/-0.0207 0.0159 +/-0.0207 0.0317 pCi/g Potassium-40 9.20

+/-0.921 0.162

+/-0.921 0.324 pCi/g Radium-226 0.340

+/-0.0907 0.0343 +/-0.0907 0.0686 pCi/g Silver-108m U -0.0333

+/-0.0171 0.013 +/-0.0171 0.0259 pCi/g Thallium-208 0.148

+/-0.0447 0.0166 +1-0.0447 0.0332 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

-0.0146

+/-0.0201 0.0202 +/-0.0201 0.0497 pCi/g KSD1 04/19/07 1534 624917 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 IMBI1 04/12/07 1115 624889 The following Analytical Methods were performed Method Description 2

3 EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 905.0 Modified Page 20 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-008F Project:

YANK01204 Sample ID:

184029001 Client ID:

YANKO0 I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 61 (25%-1 25%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 21 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-016J 184029002 TS 10-APR-07 12-APR-07 Client 3.93%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKO0l Parameter Qualifier Result Uncertainty LC TPU MBA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.523

+/-0.194 0.0888

+/-0.194 0.178 pCi/g MIHI 04/16/07 1042 624979 Americium-241 UI 0.00

+/-0.0395 0.0355 +/-0.0395 0.0709 pCi/g Bismuth-212 U

0.210

+/-0.298 0.235

+/-0.298 0.470 pCi/g Bismuth-214 0.311

+/-0.133 0.0386

+/-0.133 0.0771 pCi/g Cesium-134 U

0.0286

+/-0.0285 0.0274 +/-0.0285 0.0548 pCi/g Cesium-137 U -0.00662

+/-0.0268 0.0221 +/-0.0268 0.0443 pCi/g Cobalt-60 U

0.01 54

+/-0.0291 0.0263 +/-0.0291 0.0526 pCi/g Europium-152 U -0.00187

+/-0.0784 0.0603 +/-0.0784 0.120 pCi/g Europium-154 U

0.0884

+/-0.0954 0.0891 +/-0.0954 0.178 pCi/g Europium-I 55 U

0.00293

+/-0.060 0.0547

+/-0.060 0.109 pCi/g Lead-21 2 0.47 9

+/-0.0848 0.0315 +/-0.0848 0.063 pCi/g Lead-214 0.421

+/-0.109 0.0433

+/-0.109 0.0864 pCi/g Manganese-54 U

0.00914

+/-0.0254 0.023 +/-0.0254 0.046 pCi/g Niobium-94 U

0.011

+/-0.0249 0.022 +/-0.0249 0.044 pCi/g Potassium-40 8.71

+/-1.08 0.184

+/-1.08 0.367 pCi/g Radium-226 0.311

+/-0.133 0.0386

+/-0.133 0.0771 pCi/g Silver-108m U -0.00814

+/-0.0229 0.0195 +/-0.0229 0.039 pCi/g Thallium-208 0.124

+/-0.0641 0.0202 +/-0.0641 0.0404 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strontium-90 U

-0.0115

+/-0.0162 0.0147 +/-0.0162 0.0323 pCi/g KSDl 04/16/07 2258 624917 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 04/12/07 1115 624889 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Page 22 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analy:sis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

April 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-016J Project:

YANKOI1204 Sample ID:

184029002 Client ID:

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr9O, solid-ALL FSS 78 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 23 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Report Date:

April 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-017J 184029003 TS 10-APR-07 12-APR-07 Client 4.32%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL ESS 226 In growth Waived Actinium-228 0.615

+1-0.170 0.0613

+/-0.170 0.123 pCi/g MJH1 04/16/07 1042 624979 Americium-241 U

0.0872

+/-0.113 0.0755

+/-0.113 0.151 pCi/g Bismuth-212 U

0.187

+/-0.216 0.131

+/-0.216 0.261 pCi/g Bismuth-214 0.432

+/-0.0914 0.0362 +/-0.0914 0.0724 pCi/g Cesium-I 34 UI 0.00

+/-0.0297 0.0244 +/-0.0297 0.0487 pCi/g Cesium-137 U

0.00734

+/-0.0223 0.0199 +/-0.0223 0.0398 pCi/g Cobalt-60 U

0.015

+/-0.0226 0.0208 +/-0.0226 0.0416 pCi/g Europium-152 U

0.0363

+/-0.0645 0.052 +/-0.0645 0.104 pCilg Europium-154 U

0.0489

+/-0.0781 0.0706 +/-0.0781 0.141 pCilg Europium-ISS U

0.0606

+/-0.0551 0.0518 +/-0.0551 0.103 pCi/g Lead-212 0.464

+/-0.0754 0.0398 +/-0.0754 0.0795 pCi/g Lead-214 0.530

+/-0.0869 0.0355 +/-0.0869 0.0709 pCi/g Manganese-54 U

0.00402

+/-0.0221 0.0191 +/-0.0221 0.0382 pCi/g Niobium-94 U

0.00651

+/-0.0198 0.0176 +/-0.0198 0.0352 pCi/g Potassium-40 9.64

+/-1.05 0.181

+/-1.05 0.363 pCi/g Radium-226 0.432

+/-0.0914 0.0362 +/-0.0914 0.0724 pCi/g Silver-108m U

0.0258

+/-0.0322 0.0177 +/-0.0322 0.0353 pCi/g T'hallium-208 0.183

+/-0.0436 0.0182 +/-0.0436 0.0363 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 0.0573

+/-0.020 0.0116 +/-0.0201 0.0261 pCi/g KSD1 04/16/07 2258 624917 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 IMBi1 04/12/07 1115 624889 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Page 24 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analy:sis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

April 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-017J Project:

YANK01204 Sample ID:

184029003 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-P.L. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 25 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-01 8J 184029004 TS 10-APR-07 12-APR-07 Client 4.3%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.426

+/-0.156 0.0577

÷1-0.156 0.115 pCi/g MJHI 04/16/07 1043 624979 Americium-241 U

0.0454

+/-0.0614 0.0523 +/-0.0614 0.105 pCi/g Bismuth-212 UI 0.00

+/-0.224 0.162

+/-0.224 0.323 pCi/g Bismuth-214 0.413

+/-0.0806 0.0274 +/-0.0806 0.0547 pCi/g Cesium-I 34 U

0.0263

+/-0.0228 0.0189 +/-0.0228 0.0378 pCi/g Cesium-137 U -0.00417

+/-0.0182 0.0151

+/-0.0182 0.0302 pCi/g Cobalt-60 U -0.00237

+/-0.0189 0.0156 +/-0.0189 0.0312 pCi/g Europium-152 U

-0.0408

+/-0.0513 0.0391

+/-0.0513 0.0781 pCi/g Europiumn-154 U

0.0285

+/-0.0592 0.0524 +/-0.0592 0.105 pCi/g Europium-155 U -0.00628

+/-0.0469 0.0424 +/-0.0469 0.0847 pCi/g Lead-212 0.489

+/-0.0599 0.0234 +/-0.0599 0.0468 pCi/g Lead-214 0.457

+/-0.0794 0.0285 +/-0.0794 0.057 pCi/g Manganese-54 U

0.0114

+/-0.0183 0.0167 +/-0.0183 0.0334 pCi/g Niobium-94 U

0.00235

+/-0.0177 0.0151 +/-0.0177 0.0302 pCi/g Potassium-40 10.1

+/-0.938 0.110

+/-0.938 0.219 pCi/g Radium-226 0.413

+/-0.0806 0.0274 +/-0.0806 0.0547 pCi/g Silver-108m U -0.00456

+/-0.0162 0.014 +/-0.0162 0.0279 pCi/g Thallium-208 0.137

+/-0.0382 0.0153 +/-0.0382 0.0305 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.0179

+/-0.0157 0.0114 +/-0.0158 0.0255 pCi/g KSDl 04/16/07 2259 624917 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/12/07 1115 624889 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Page 26 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analy:sis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

April 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04 002332 Client Sample ID:

9514-O000-018J Project:

YANKOI1204 Sample ID:

184029004 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Surrogate/Tracer recovery Test Recovery%

Acceptable Linits Strontium Carrier GFPC, Sr90, solid-ALL FSS 79 (25%-I125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCJMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 27 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel~com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9514-0000-019B 184029005 TS 10-APR-07 12-APR-07 Client 4.53%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 1.08

+/-0.190 0.064

+/-0.190 0.128 pCi/g MJH1 04/16/07 1356 625519 Americium-241 U

0.131

+/-0.0818 0.0703 +1-0.0818 0.141 pCi/g Bismuth-212 0.465

+/-0.378 0.151

+/-0.378 0.302 pCi/g Bismuth-214 0.762

+/-0.125 0.0368

+/-0.125 0.0736 pCi/g Cesium-134 UI 0.00

+/-0.0297 0.0253 +/-0.0297 0.0506 pCi/g Cesium-] 37 U

-0.0138

+/-0.0241 0.0196 +/-0.0241 0.0391 pCi/g Cobalt-60 U

0.02 18

+/-0.0269 0.0207 +/-0.0269 0.0415 pCi/g Europium-152 U

-0.0305

+/-0.0682 0.0509 +/-0.0682 0.102 pCi/g Europium-I 54 U

-0.0734

+/-0.0754 0.0571

+/-0.0754 0.114 pCi/g Europium-155 U -0.00189

+/-0.0643 0.0577 +/-0.0643 0.115 pCi/g Lead-212 1.01

+/-0.100 0.0268

+/-0.100 0.0536 pCi/g Lead-214 0.957

+/-0.121 0.0346

+/-0.121 0.0692 pCi/g Manganese-54 U

0.0339

+/-0.0265 0.0188 +/-0.0265 0.0376 pCi/g Niobium-94 U

0.0137

+/-0.027 0.0205

+/-0.027 0.0409 pCilg Potassium-40 14.9

+/-1.31 0.161

+/-1.31 0.321 pCilg Radium-226 0.762

+/-0.125 0.0368

+/-0.125 0.0736 pCi/g Silver-108m U

0.00362

+/-0.0196 0.0172 +/-0.0196 0.0345 pCi/g Thallium-208 0.262

+/-0.0508 0.0187 +/-0.0508 0.0373 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strontium-90 0.0484

+/-0.0223 0.0138 +/-0.0223 0.0313 pCi/g KSDI 04/16/07 2259 624917 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/12/07 1115 624889 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Page 28 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

April 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9514-0000-019B Project:

YANK01204 Sample ID:

184029005 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU NMA Units DF Analyst Date Time Batch l'i Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 69 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 29 of 39

r 1

QUALITY CONTROL DATA I I Page 30 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary

'lient :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: April 19, 2007 Page 1 of 9 East Hampton, Connecticut

.ontact:

Mr. Jack McCarthy Vorkorder:

184029 armname ad Gamma Spec itch 624979 NOM Sample Qual QC Units RPD%

REC %

Range Anist Date Time

,ctinium-228

,mericium-241

ismuth-2 12
ismuth-2 14

.esiun-1 34

,esium-] 37

.obalt-60 uropiun-1 52

,uropium-154

.uropium-1 55

,ead-21 2

,ead-21 4 langanese-54 liobium-94 184029004 DUP 0.426 Uncert:

+1-0.156 TPU:

+/-0.156 U

0.0454 Uncert:

+/-0.0614 TPU:

+1-0.0614 Ul 0.00 Uncert:

+/-0.224 TPU:

+/-0.224 0.413 Uncert:

+/-0.0806 TPU:

+/-0.0806 U

0.0263 Uncert:

+/-0.0228 TPU:

+/-0.0228 U

-0.00417 Uncert:

+/-0.0182 TPU:

+/-0.0182 U

-0.00237 Uncert:

+/-0.0189 TPU:

+/-0.0189 U

-0.0408 Uncert:

+/-0.0513 TPU:

+/-0.0513 U

0.0285 Uncert:

+/-0.0592 TPU:

+/-0.0592 U

-0.00628 Uncert:

+/-0.0469 TPU:

+/-0.0469 0.489 Uncert:

+/-0.0599 TPU:

+/-0.0599 0.457 Uncert:

+/-0.0794 TPU:

+1-0.0794 U

0.0114 Uncert:

+/-0.0183 TPU:

+/-0.0183 U

0.00235 Uncert:

+/-0.0177 TPU:

+/-0.0177 0.459

+/-0.155

+/-0.155 U

0.0245

+/-0.0782

+/-0.0782 0.372

+/-0.305

+/-0.305 0.436

+/-0.0924

+/-0.0924 U

0.0218

+/-0.0339

+/-0.0339 U

0.002

+/-0.0195

+/-0.0195 U

-0.00244

+/-0.0179

+/-0.0179 U

-0.00651

+/-0.059

+/-0.059 U

-0.00323

+/-0.0585

+/-0.0585 U

0.0343

+/-0.05 13

+/-0.0513 0.479

+/-0.0617

+/-0.0617 0.412

+/-0.0797

+/-0.0797 U

-0.000555

+/-0.0208

+/-0.0208 U

0.00242

+/-0.0169

+/-0.0169 pCi/g 8

pCilg 60 pCilg 10 pCi/g 5

pCilg 19 pCi/g 569 pCilg 3

pCi/g 145 pCi/g 251 pCi/g 290 pCi/g 2

PCi/g 10 (0% - 100%) MIHI1 04/16/07 13:54 (0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

PCilg 220 (0% -100%)

(0% -100%)

pCi/g 3

Page 31 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 armname ad Gamma Spec itch 624979 otassium-40

.adium-226 ilver-lO8m

'hallium-208 Page 2 of 9 Range AnIst Date Time NOM SaMrile OuaI OC Units RPD%

REC%

10.1 Uncert:

+/-0.938 TPU:

+/-0.938 0.413 Uncert:

+/-0.0806 TPU:

+/-0.0806 U

-0.00456 Uncert:

+/-0.0162 TPU:

+/-0.0162 0.137 Uncert:

+/-0.0382 TPU:

+/-0.0382

.ctinium-228

,mericium-241 LCS

-ismuth-212

.ismuth-214 eIum 3

,esium-137 Uncert:

TPU:

16.0 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

6.19 Uncert:

TPU:

9.28 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.57

+/-1.02

+/-1.02 0.436

+/-0.0924

+/-0.0924 U

0.00556

+/-0.0164

+/-0.0164 0.154

+/-0.0393

+/-0.0393 0.936

+/-0.600

+/-0.600 12.5

+/-1.03

+/-1.03 2.48

+/-1.35

+/-1.35 0.909

+/-0.309

+/-0.309 0.190

+/-0.0993

+/-0.0993 5.71

+/-0.530

+/-0.530 8.93

+/-0.634

+/-0.634 U

0.111

+/-0.238

+/-0.238 U

-0.0578

+/-0.206

+/-0.206 U

0.144

+/-0.236

+/-0.236 0.682

+/-0.242

+/-0.242 0.861

+/-0.284 pCi/g 5

pCilg 5

pCi/g 2030 pCi/g 12 pCi/g (0% -20%)

(0% -100%)

(0% -100%)

(0% -100%)

.obalt-60 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 04/16/07 13:55 92 (75%-125%)

96 (75%-125%)

78 (75%-125%)

,uropium-152

.uropium-154

,uropium-155

,ead-21 2

,ead-214 Uncert:

Page 32 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 3 of 9 armname NOM Sample Qual OC Units RPD%

REC %

Range AnIst Date Time ad Gamma Spec itch 624979 TPU:

langanese-54 liobium-94 otassium-40

.adium-226 ilver-108m bnallium-208 QC 12013 13865

,ctinium-228

,mericium-241 MB Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.284 U

-0.0751

+/-0.0865

+/-0.0865 U

-0.0344

+1 -0.0846

+/-0.0846 U

0.938

+/-1.03

+/-1.03 0.909

+1-0.309

+/-0.309 U

0.0701

+/-0.0795

+/-0.0795 0.372

+1-0.147

+/-0.147 U

-0.02

+1-0.0506

+/-0.0506 U

0.000275

+1-0.0504

+1-0.0504 U

0.096

+/-0.0927

+/-0.0927 U

0.0177

+1-0.045

+/-0.045 U

0.00481

+/-0.0131

+/-0.0131 U

-0.00391

+/-0.0132

+/-0.0132 U

0.00699

+/-0.0132

+/-0.0132 U

-0.00356

+/-0.0316

+/-0.0316 U

-0.0281

+/-0.0387

+/-0.0387 U

0.00361 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75 %-125%)

04/16/07 13:54

ismuth-21 2

.ismuth-214

.esium-134

.esium-137

.obalt-60

.uropium-152

,uropium-154

,uropium-155 Page 33 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 4 of 9 armname NOM Sample Qual OC Units RPD%

REC%

Ranee AnIst Date Time ad Gamma Spec itch 624979

.ead-21 2

.ead-214 langanese-54 tiobium-94 otassium-40

.adium-226 ilver-1 08m Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

hallium-208 itch 625519

+/-0.029

+/-0.029 U

0.0167

+/-0.0324

+/-0.0324 U

-0.0217

+/-0.0276

+/-0.0276 U

-0.00843

+/-0.0128

+/-0.0128 U

0.00454

+/-0.0133

+/-0.0133 U

0.00683

+/-0.193

+1-0.193 U

0.0177

+1-0.045

+/-0.045 U

-0.0035 1

+/-0.0127

+/-0.0127 U

-0.00829

+/-0.0161

+/-0.0161 0.608

+/-0.183

+/-0.183 U

0.032

+/-0.0236

+/-0.0236 U

0.395

+/-0.252

+/-0.252 0.503

+/-0.121

+/-0.121 UI 0.00

+/-0.0444

+/-0.0444 U

0.0107

+/-0.0254

+/-0.0254 U

-0.0142

+/-0.0235 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg

,ctinium-228

,mericium-241

.ismnuth-21 2

.ismuth-21 4 esium-134 esium-1 37

.obalt-60 0.522 Uncert:

+/-0.132 TPU:

+/-0.132 U

0.026 Uncert:

+/-0.0682 TPU:

+/-0.0682 UI 0.00 Uncert:

+/-0.167 TPU:

+/-0.167 0.459 Uncert:

+/-0.0869 TPU:

+/-0.0869 U

0.0223 Uncert:

+/-0.0275 TPU:

+/-0.0275 0.0281 Uncert:

+/-0.0239 TPU:

+/-0.0239 U

0.00538 Uncert:

+/-0.0175 pCi/g 15 pCi/g 21 pCi/g 13 pCi/g 9

pCi/g 85 pCi/g 89 pCi/g 443 (0% -100%) MJIi 04/17/07 09:11 (0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

Page 34 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 5 of 9 Ranee AnIst armname NOM Sanmle OuaI OC Units RPD%

REC %

Date Time armname ad Gamma Spec itch 625519

,uropium-152

,uropium-154

,uropium-1 55

,ead-21 2

.ead-214 langanese-54 liobium-94 otassium-40

.adium-226 ilver-108m hallium-208 QC 12013 15242

,ctinium-228

,mericium-241

ismuth-21 2 TPU

+/-0.0175 u

0.0238 Uncert:

+/-0.0609 TPU:

+/-0.0609 u

0.0124 Uncert:

+/-0.0562 TPU:

+/-0.0562 u

-0.0291 Uncert:

+/-0.05 19 TPU:

+/-0.0519 0.547 Uncert:

+/-0.0594 TPU:

+/-0.0594 0.496 Uncert:

+/-0.0742 TPU:

+/-0.0742 U

0.00646 Uncert:

+/-0.0156 TPU:

+/-0.0156 u

0.0109 Uncert:

+/-0.017 TPU:

+/-0.017 12.0 Uncert:

+/-0.987 TPU:

+/-0.987 0.459 Uncert:

+/-0.0869 TPU:

+/-0.0869 u

0.00418 Uncert:

+/-0.0141 TPU:

+/-0.0141 0.168 Uncert:

+/-0.0297 TPU:

+/-0.0297

+/-0.0235 U

-0.0204

+/-0.0786

+/-0.0786 U

0.019

+/-0.070

+/-0.070 U

0.0775

+/-0.0516

+/-0.0516 0.488

+/-0.0792

+/-0.0792 0.568

+/-0.101

+/-0.101 U

0.00343

+/-0.024

+/-0.024 U

-0.014

+/-0.0224

+/-0.0224 11.2

+/-1.17

+/-1.17 0.503

+/-0.121

+/-0.121 U

0.00558

+/-0.0198

+/-0.0198 0.150

+/-0.0478

+/-0.0478 1.02

+/-0.578

+/-0.578 14.0

+/-1.66

+/-1.66 U

0.627

+/-0.764

+/-0.764 0.624

+/-0.244

+/-0.244 U

0.0266 pCi/g 2660 pCi/g 42 pCi/g 440 pCi/g 12 pCi/g 14 pCi/g 61 pCi/g 1630 pCi/g 6

pCi/g 9

pCi/g 29 pCi/g 12 (0% -100%)

(0% -100%)

(0% -100%)

(0%-20%)

(0%-20%)

(0% -100%)

(0% -100%)

(0% -20%)

(0% -100%)

(0% -100%)

(0% -100%)

LCS Uncert:

TPU:

16.0 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

pCi/g pCi/g pCi/g pCi/g pCi/g 04/17/07 09:10 87 (75%-125%)

ýismnuth-214

.esium-134 Page 35 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 armname ad Gamma Spec itch 625519 Page 6 of 9 REC%

Range AnIst Date Time NOM Sample Qual QC Units RPD%

.esium-137

.obalt-6

,uropium-152

,uropium-154

,uropium-1 55

.ead-21 2

.ead-214 langanese-54 fiobium-94 otassium-40

.adium-226 Uncert:

TPU:

6.19 Uncert:

TPU:

9.28 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.111

+/-0.111 5.89

+/-0.546

+/-0.546 9.15

+/-0.717

+/-0.7 17 U

-0.142

+/-0.294

+/-0.294 U

-0.147

+/-0.283

+/-0.283 U

0.00105

+1-0.269

+/-0.269 0.937

+/-0.230

+/-0.230 0.665

+1-0.260

+1-0.260 U

-0.0119

+1-0.0972

+/-0.0972 U

-0.00404

+/-0.0942

+1-0.0942 U

1.06

+/-1.02

+/- 1.02 0.624

+/-0.244

+/-0.244 U

-0.0182

+/-0.089

+1-0. 089 0.317

+/-0.187

+1-0.187 U

0.0048

+/-0.108

+1-0.108 U

0.0157

+1-0.033

+/-0.033 pCi/g pCilg pCilg pCilg pCilg pCilg pCilg pCilg pCilg pCilg pCilg pCu/g pCilg pCilg pCilg 95 (75%-125%)

99 (75%-125%)

(75 %-125%)

ilver-I 08m

'hallium-208 QC1201315240 MB

,ctinium-228

.mericium-241 04/17/07 09:11 Page 36 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 7 of 9 armname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time ad Gamma Spec itch 625519

ismuth-21 2 U

0.107 pCi/g Uncert:

+/-0.193 TPU:

+/-0.193

ismuth-2 14 U

-0.00637 pCi/g Uncert:

+/-0.053 1 TPU:

+/-0.053 1

.esium-134 U

0.00663 pCi/g Uncert:

+/-0.0243 TPU:

+/-0.0243

.esium-1 37 U

-0.0133 pCi/g Uncert:

+/-0.0269 TPU:

+/-0.0269

.obalt-60 U

-0.0238 pCi/g Uncert:

+/-0.0262 TPU:

+/-0.0262

.uropium-152 U

-0.00193 pCi/g Uncert:

+/-0.0671 TPU:

+/-0.067 1

,uropium-154 U

0.0251 PCi/g Uncert:

+/-0.0689 TPU:

+/-0.0689

,uropium-155 U

0.000307 pCi/g Uncert:

+/-0.0525 TPU:

+/-0.0525

  • ead-21 2 U

0.0203 pCi/g Uncert:

+/-0.0405 TPU:

+/-0.0405

,ead-21 4 U

0.0266 pCi/g Uncert:

+/-0.0659 TPU:

+/-0.0659 langanese-54 U

-0.00236 pCi/g Uncert:

+/-0.0236 TPU:

+/-0.0236

[iobium-94 U

0.01 03 pCi/g Uncert:

+/-0.0279 TPU:

+/-0.0279 otassium-40 U

-0.17 pCi/g Uncert:

+/-0.297 TPU:

+/-0.297

,adium-226 U

-0.00637 pCi/g Uncert:

+/-0.0531 TPU:

+/-0.053 1 ilver-1I08m U

0.0101 pCi/g Uncert:

+/-0.0222 TPU:

+/-0.0222 hallium-208 U

-0.0122 pCi/g Uncert:

+/-0.0295 TPU:

+/-0.0295 Page 37 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 8 of 9 armname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time ad Gas Flow itch 624917 QC1201313722 184029002 DUP trontium-90 U

-0.0115 U

-0.0163 pCi/g 0

(0% - 100%) KSD1 04/16/07 22:58 Uncert:

+/-0.0162

+/-0.0138 TPU:

+/-0.0162

+/-0.0138 QC1201313724 LCS trontium-90 1.41 1.44 pCi/g 102 (75%-125%)

04/16/07 22:59 Uncert:

+/-0.105 TPU:

+/-0.114 QC1201313721 MB trontium-90 U

0.0164 pCi/g 04/16/07 22:58 Uncert:

+/-0.0145 TPU:

+/-0.0145 QC1201313723 184029002 MS trontium-90 1.59 U

-0.0115 1.22 pCi/g 77 (75%-125%)

04/16/07 22:58 Uncert:

+/-0.0162

+/-0.102 TPU:

+/-0.0162

+/-0.109 N4otes:

1'he Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL ht Preparation or preservation holding time was exceeded Page 38 of 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:

184029 Page 9 of 9 armname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time I/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

  • Indicates analyte is a surrogate compound.

The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the ample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is

-ss than 5X the RL, a control limit of +1-the RL is used to evaluate the DUP result.

Ior PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Vhere the analytical method has been performed under NELAP certification, the analysis has met all of the

-quirements of the NELAC standard unless qualified on the QC Summary.

Page 39 of 39

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

I lealth Iliv, sics l1rocedure (il'I'AlOOR-R5121-001 Attachment 15. RcNý CY-00 I '0AJOR I Icaith I'hx sies Procedure (jPP-(,(AR-R5 121 -0(11 Attachment 13. Res (Y4)tl I \\1AJ( )R Preliminary Data Review Form - Samples for the Sign Test Sunrsc% I 'nit:

SuarN ox I it Name:

Survex Miedia:

I \\pe ot'Sur\\w c:

I \\ pe Ofl Meisurement:

Number of Mea-surements:

Operational DCGL.:

9514 0000 West Primary Parking Lot 3

soil Finail Status Survey Gross Measurement 15 I IA S I SIl ATI lSIllCA 1, Q I IA NTI*HI 'S Cs-137 C'o-60)

Sr-90 Minimum Value:

Maximum Value:

Mean:

Median:

Standard D~eiation:

Skew~:

-9.25E-03

-1.30E-02

-1.46E-02 9.54E__02 2.50E-02 j 3.59E-02 2.72E-02 j7.2$E-03 7.35E-03 2.29E-02 7.60E-03 5.20E-03 2.77E-02 1.07E-02 1.3 1E-02 I1.2413+00

-1.1 OE-OI 7.30E-01 RAD)IONU.CLIDE ('ONCELNTRAIION (pti/g)

Nt N'lE1i Cs-137 Co-60 Sr-90 Cs Identified? Co Identified'?

Sr Identified?

9514-0000-001 F 4.22E-02 1.17E-02 7.52E-03 YES NO NO 9514-0000-=0F 2.5112-02 1.40E-02 9.72E-03 YES NO NO 9514-0000-003F 1.83E-02 6.70E-03 4.68E-03 NO NO NO 9514-0000-004F 2.57E-02 4.04E-03 3.59E-02 NO NO YES 9514-0000-005F 2.59E-02

-5.42E-03 5.20E-03 NO NO NO 95144)000-006F 7.25E-02 7.60E-03 7.99E-05 YES NO NO 95 14-0000-007F 2.29E-02

-3&77E-03 3.04E-02 YES NO YES 9514-000-008F

-1.73E-03

-5.12E.04

-1.48E-02 NO NO NO 9514-0000-009F 6.27E-03 2.24E-04 4.71E-03 NO NO NO 9514-0000-OIOF 1.41E-02 1,31E-02

-2.34E-03 NO NO NO 9514-0000-01 IF 4.48E-02 8.1'JE-03 9.49E-03 YES NO NO 9514-0000-012F 2.29E-02 2.10E-02

-9.25E-03 YES NO NO 9514-0000-013F

  • 9.25E-03

-1.30E-02 2.76E-03 NO No NO 9514-0000-014F 954E-02 2.50E-02 9.02E-03 YESN NO 9514-0000-015F t

3.26E -03 2.04E-02 I

1I70E-02NON NO

/

IDatc:

L/- ? I-6&

7 D~ate: 412. 0'7_

I ifalth Physics ProcfdUrf 24265-000-(;PP-GGGR-R5 123 -000-Rev.C)'-00(

II taith Physics Procfdurf 24265-OO(J-( 1PP-((i( ~R-RS I 23-000-Rex.CY-OOt Preliminary D~ata Review Form -.Judgemental Samples Sursexy Unit:

Survey U'nit Name:

Class ificat ion:

Survey Media:

lype oc Survey:

I ype oe Mleasurement:

Number of MIeasurements:

Operational DC61L:

9514-00 West Primary Parking Lot Final Status Survey Gross Measurement 4 1 1

1 1z I

BIASIC STATISTICALQUANTITIES______

Cs-137 Co-60 Sr-90

\\niumValue:

-1.38E-02

-2.37E-03

-1.15E-02 Mlaximum Value:

7.34"-3 2.18E-02 5.73E-02 Mean:

-4.31E-03 1.25E-02 2.80E-02

  • Median:

-5.40E-03 1.52E-02 3.32E-02 Standard Deviation:

8.78E-03 l.04E-02 3.13E-02 RA DION UC-IDE CONCENTRATION (p~i'g)

NUMBER Cs-137 Cs I D'ed'?

Co-60 Co ID'ed Sr-90 Sr ID'ed

> I)CGL 9514-0000-016J

-6.62E-03 NO 1.54E-02 NO

-1.15E-02 NO NO 9514-0000-017J

-7.34E-03 NO 1.50E-02 NO 6.73E-02 YES NO 9514-0000-01 8J 4.17E-03 NO

-2.37E-03 NO 1.79E-02 YES NO 9514-0000-019B

-1,38E-02 NO 2.18E-.02 NO 4.84E-02 YES NO Pertbrined 13,,

Independent Re% iew Date:

[Date:

-4 I2 1-,/-c)

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

I lealth llllýsics IlrocedUre 6G(j R-R5 1'-)3-Rev.('Y-00 I Attachnictit (

Quantile Plot For Cesium - 137 Irc~L'nilt 9514-0000 NL~r~c\\

n~it Nancý West Primary Parking Lotn lcanl 2172L1-02 p('i g 0)

'-p m

0 1.20E-01 l.OQE-01 8 OOE-02 6 OOE-02 4.OOE-02 2.OOE-02 0.OOE+00

-2.OOE-02

.p

+

10 20 40 60 80 Percentage Cs-i 37 Rank Percentage

-9.25E-03 1

3 %

-1.73E-03 2

10 %

3.26E-03 3

17 %

6.27E-03 4

23 %

1.41 E-02 5

30 0/

1.83E-02 6

37 %

2.29E-02 7

43 %

2.29E-02 8

50 %

2.51 E-02 9

57 %

2.57E-02 10 63 %

2.59E-02 11 70 %

4.22E-02 12 77 %

4.48E-02 13 83 %

7.25E-02 14 90 %

9.54E-02 15 97 %

Prepared By iO4 3

j L i5Q\\

6 ReviewedB.i Date.

-2 V-C7 Date:

41 ?_( 107

I lealth I)hysics Procedure IGGR-R5 I 23-Rev.('Y-00 I Attachment Quantike Plot For Cobailt - 60 Survey Unit:

Stirvev Un fit Name:

Niealn:

9514-0000 WAest P~rimary P~arking Lot 7.28k-tB p('i/g 0.

0 2.20E-02 1, 70E-02 1 20E-02 7 OOE-03 2.QOE-03 9

-3.OOE-03 $)

100O 20.*

40 60 80

-8. OOE-03

-1.30E-02 I*

Percentage Co-60

-1.30E-02

-9.79E-03

-5.42E-03

-3,77E-03

-5.12E-04 2.24E-04 4.04E-03 6.70E-03 8.17E-03

1. 17E-02 1.31 E-02 1.40E-02 2.04E-02
2. 1OE-02 2.50E-02 Rank 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 Percentage 3 %

10%0/

17 %

23 %

30 %

37 %/

43 %

50 %

57 %

63 %

70 %

77 %

83 %

90 %

97 %

Prepared By:

Datei 7 2 V-A 6 7 Date:

2.jjp Ic7

I lealth Physics Procedure GGGlk-Ik5 Y-00 I Attachment C I leahh Physics Procedure (i(i(iR-RS I '3-Rev ('Y-0OI Attachment C' Quantile Plot F'or Strontiunt-90 SullVey Unit:

9514-0000 Survey Unit Name: West Primary Parking Lot Mean:

7.35[-03 pATI/

3.50E-02 S2.50E-02

.o 1.50E-02 S500OE-03 0

()' -5.OOE-03

)

20 140~

40 60 80 1 4-

-1.50E-02 Percentage

-1.46E-02

-9.25E-03

-2.34E-03 7.99E.-05 2.76E-03 4,68E-03 4.71 E-03 5.20E-03 7.52E-03 9.02E-03 9.49E-03 9.72E-03 1.70E-02 3.04E-02 3.59E-02 Rank 2

3 4

5 6

.7 8

9 10 11 12 13 14 15 Percentage 3%

10 %

170/%

23 %

30 %

37 %

43 %/

50 %

57 %

63 %

70 %

77 %

83 %

90 %/

97 %/

Prepared By 2b---

-i Reviewed B I/1 Date:_ý? Y-2 C

Datei 4 1.C &

I Icaith Physics Procedure (iGi6R-R5 I 23-Rev.-. Y-00 I Attachment C Frequency Plot For Cesium-137 Survey Unit:

95 14-)0000 Survey Unit Name: West Primary Parking L ot Mean:

0.027 p('i/g C.D LL 6

5 4

3 2

1 0

0.000 0.020 0.040 0.060 0.080 0.100 Upper End Value (pCilg)

Upper End Observation Value Frequency 0.000 2

0.020 4

0.040 5

0.060 2

0.08 1

0.100 1

Total 15 Observation %

Frequency 13%

27%

33%

13%

7%

7%

100%

Prepared By:

D~ate:

$ýrL %-ci Reviewed y-Dt:

II /7 Date: qIZ-(ojC)7

I lealth Illysics Procedure I Icith hysis Pocedre (GiGR-R5 123-Rex,.CY-(J( I Attachment C Frequency Plot For Cobalt-60 SUrvey U'nit:

951I4-0000)

SUrvey I mnit Name: West Primary P~arking Lot Mean:

0).007 p('i/g Cr I-LI.

5 4

3 2

1 0

-J 0.000 0.005 0.010 0.015 0.020 0.025 Upper End Value (pCilg)

Upper End Observation Observation %

Value Frequency Frequency 0,000 4

27%

0,005 2

13%

0,010 3

20%

0.015 3

20%

0.020 0

0%

0.025 3

20%

Total 15 100%

Z, I

j

-A~jv, Prepared By:

Reviewed fBy:

L2 D~ate:

'/q D~ate: 4j2-(, /c7

I Icalth Physics Procedure I Icith ~h~

ics roceure G(iGR-R5 1231-Rex.('Y-001 Attachment C' Frequency Pl~ot For Sr - 90 95 14-0000 West Primary Parking Lot Surve-y Unit:

Surv'ey Unit Namne:

Mean:

0.007 pCi/g 10 C

0~

L-U1.

8 6

4 2

0

-0.010 0.000 0.010 0.020 0.030 0.040 Upper End Value (pCi/g)

Upper End Value

-0.010 0.000 0.010 0 02 0.030 0 040 Total Observation Frequency 1

2 9

1 0

2 15 Observation %

Frequency 7%

13%

60%

7%

0%

13%

100%

Prepared By:

L D~ate:

v2-

ý,-, -

-7 ReviewedB>

D~ate: I

./C-

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

I lealth ['It% sics Procedure 6l'P-GPkiG;R-R512J-000 Attachment A. Ro. ( Y-001 MAJOR I kaith Ph~ ~

I~roccdurc

(;I'I'-(,(i( ~R-R5 121 dX)O Aitaihnicm A. Rex ( Y-(JO I \\1AJ( )R Sign Test Calculation Sheet For Multiple Radionuclisdles Surx c% 1 ~ Nu 9514-)0000

-Surxex I "nit Name: Wes cxl rimafn Parking L ot W P& IR;1: \\A Classification :3 1 NTL1 I ((x cffor):0.05 I I P1:L I W error ):0.05 RadiOnuclideS:

Cs-137 Co-60 2,59 Sr-90 1 A5 Operational DCI

)(

(p(ig) 5.38 Results Cs.- 13 7 4.2213-02 2.5 1 E-02 1.93E-02 2.57E-02 1.59E..02 7.25E-02 2.29E-02

-1.73E-03 6.27E-03 1.4 E-02 4.49E-02 2.29E-02

-9.25E-03 9.54E-02 3.26E-03 Results Co-60

1. 17E-02 1.40E-02 6.70E-03 4.04E-03

-5.42E-03 7.60E-03

-3.77E-03

-5. 12E-04 2.24E-04 1.31 E-02 8.17F.-03

2. 1OE..02

-1.30E-02 2.50E-02 2.04E-02 Results Sr-9()

Weighted Sum (\\,k:,

I)(i~IL-Result 7.52E..03 9.72E-03 4.68E-03 3.59E-02 5.20E-03 7.99E-05 3.04E-02

-1.46E-02 4.71E-03

-2.34E-03 9.49E-03

-9.25E-03 2.76E-03 9.02E-03 1.70E-02 1.95E-02 1.93E-02 1,04E-02 4.OSE-02 7.67E-03 1.59E-02 1.6715-02 2.40E-02 5.74E-03 5.45E-03 2.OSE-02 3.56E-03

-4.11 E-03 3.60E-02 2.47E-02 9.90E-0O1 9.81 E-0 I 9.90E-01 9.59E-01 9.92E-01 9.94E-01 9.83E-01 9.76E-01 9.94E-01 9.95E-01 9.79E-01 9,96E-Oi 1.OOE+0O 9.64E-01 9.75E-01 Number of Positive Differences (S t):

15 Critical Value; 13 Surxex ('nit:

kleets Acceptance Criterion I2I 1'ertborred lB\\

T.

~ f

'i Independent Re\\ iexx 9

lDate.

1

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Connecticci~ut Yankee I ecommis sioning P1roject I lea ithI Ph% sic,, Procedure 24205-0004iOl 'R-4( i( iR-I45 124I-000 Attachnien IA Split Sample Assessment Form Survey 9514 Survey 000 urvey Unit West Primary Parking Lot Areaft:

Unit ~;

00Name:

Sample Plan or WPIR#:

NA SMI, 4:

0 Sample

Description:

Comparison of split samples collected from sample measurement location # 14. and analyzed usint garruma spectroscopy by an off-site vendor laboratory. J he standard sample was 95 14-0000-0 14F, the comparisor sample wsas 95 14-0000-014F-S.

STAN DARD)

COMPARISON Radionuclidc Actis itN Standard Resolution Agreement Actix it,,

Standard Comparison Acceptable (Y!N)

Value Error Range Value Frro r Ratio Cs-137 3.26E-03

1. 17L-02 0

NONE -

1.13E-01I

.99E-02 34.66 NA Co-60 2.04E-02 1.371-02 1

NONE -

5. 1OE-04 1.32E-02 0.03 N A K-40 1.33lE0l 6.95E-0l 19 0.75 -

1.33 1.22F+01 6.201--0 1 0.92 Y

Comments/Corrective Actions: For both Cs-137 and Co-60, the Table is provided to show acceptance criteria used to resolution rations are less than 4. The guidance for *agreement assess split samples.

ranges, obtained from U.SNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore. at Resolution Agreement Range determination of acceptability for such rations cannot be made.

4 7

0.50 2.00 K-40 was found to be present at anl acceptable level of' 8

1 5 0.60 1.66 agreement. 1-herefore. no fuirther action is warranted.

16 50 0.75 1.33 5I 200 0.80 1.25 200t.85 I 18 Performed I1y:~-

]4ate:

Revsiewed B:

D~ate:

WPIR - Work Plan and lnspekcrion Record SMI. - Sample Measurement Location designation Page I (it I

( onriecutcut Yankcc De)commissioning Project I Icaith Vbx sics Procedure 241265 -000-( 'Rl-( i(,( R-R5 12,4-i0

)t()ttachment A Split Sample Assessmenit Form Survey 9514 Survey 000Survey Unit West Primary Parking Lot Area11:

Unit 41:

Name:

Sample p~lan or WPIR4:

NA SMI. 4;:

0 Sample

Description:

Comparison of' split samples collected from sample measurement location 0115 and analyzed usiný gamma spectroscopy by an off-site vendor laboratory.

[he standard sample was 95 14-0000-015F, the comparisor sample was 9514-O000-0l5FS.

STlANDARD COMPARISON Radionuclide Acti\\ itv Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/'N)

Value Error Range Value FError Ratio Cs-137 3.26E-03

1. 17E-02 0

NONE,-

4.12E-03

1. 14E-02 1.26 NA Co-60 2.04F-02 1.37E-02 I

NONE -

2.001--02

1. 12E-02 0.98 N A K-40 l.191'+0l 6.20E-0 1 19 0.75-1.33 1.22E+01 5.85E-01 1.03 Y

Comments/Corrective Actions: For both Cs-137 and Co-60, the resolution rations are less than 4. The guidance for agreement ranges, obtained from ( SN RC Inspection Procedure 84750.

does not address resolution ratios less than 4, therefiore, a determination of acceptability for such rations car~not be made.

K-40 was found to be present at an acceptable level of' agreement. Therefore, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.

Resolution I

Agreement Range 4

7 I5 50) 200 200 0.50 0.60 0.75 0.80 0.85; 2.00 1.66 1.33 1.25 1.18 Irerformeu 15):

WPIR - Work Plan and Inspection Record SMLI -- Sample Measurement L~ocation designation Page I of I

WEST PRIMARY PARKING LOT SURVEY UNIT 95 14-0000 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

DQA Surface Soil Report Assessment Summary Siteý Planner(s):

Survey Unit Name:

Report Number Survey Unit Samples, Reference Area Samplesý Test Performed Judgmental Samples:

Assessment

Conclusion:

West primary parking lot RWMV 9514-0000 1

15 0

Sign Test Result:

Not Performed 0

EMVC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve I.

U 2E 0.9 07 05 0.4 0.3 02 0.1 0

  • -t

.1-

-I ________

  • -I I

-I_______

0.0 02 04 016 0.8 1 0 Unity Rule Sum-of Ratios, includinig b~aikground Prospective Power U

1 -beta Actual Power LBGR Estimated Power DCGL Retrospective Power 1 2 COMPASS 0l.0.0 42/07Pg 4/24/2007 Page 1