CY-07-106, Revision 0 to Final Status Survey, Final Report Phase V, Appendix A12, Survey Unit Release Record, Book 13 of 13; Including Covers for Books 3 - 12 of 13

From kanterella
Jump to navigation Jump to search
Revision 0 to Final Status Survey, Final Report Phase V, Appendix A12, Survey Unit Release Record, Book 13 of 13; Including Covers for Books 3 - 12 of 13
ML072080400
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 07/12/2007
From:
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
CY-07-106 9520-0006
Download: ML072080400 (170)


Text

J i*<: : !:i:

3 f1 o

Final Status Survey Final Report Phase V Appendix A12 Survey Unit Release Record 9520-0006, Southwest Site Storage Area 4

July 2007

CYAPCO FINAL STATUS SURVEY RELEASE RECORD SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 Prepared By: VWTQ IAl Date: -7112 0o"7 FSS ngineer Reviewed By: Date: 7A,_/_

FSS Engineer Approved By: C.4,& 17- Date: / 7 Telhnical Support Manager Revision 0

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION........................................... 3
2. CLASSIFICATION BASIS ................................................... 3
3. DATA QUALITY OBJECTIVES (DQO).................................. 7
4. SURVEY DESIGN...........................ý*............................... 10
5. SURVEY IMPLEMENTATION .......................... ....... 14
6. SURVEY RESULTS........................................................ 15
7. QUALITY CONTROL .................. .................................. 17
8. INVESTIGATIONS AND RESULTS .................................... 18
9. REMEDIATION AND RESULTS ......................................... 18
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .......... 19.
11. DATA QUALITY ASSESSMENT (DQA)............................... 19
12. ANOMALIES ................................................................ 20
13. CONCLUSION.......................I......................................... 20
14. ATTACHIMENTS ........................................................... 21 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (4 pages including cover) 14.3 Attachment 3 - Laboratory Data (114 pages including cover) 14.4 Attachment 4 - DQA Results (14 pages- including covers)

TOTAL 159 Revision 0

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9520-0006 (Southwest Site Storage Area (non-protected area) is designated as Final Status Survey (FSS) Class 1 and consists of approximately nineteen thousand, four hundred and sixty one square feet (19,461 ft2) or one thousand eight hundred eight square meters (1,808 M 2 ) of uninhabited, undeveloped land and is located approximately one thousand eight hundred four feet (1,804 ft) from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows:

land Survey Unit 9304-0001 to the north (called north as oriented with the north to south flow of the Connecticut River), and land Survey Unit 9522-0001 to the east, south, and to the west. The survey unit is flat and de-vegetated. This is a result of soil grading in support of commodity removal.

The reference coordinates associated with this survey unit are E004 through E006 by S072 through S074 (refer to "HNP License Termination Plan" (LTP)

Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."

The "Classification Basis Summary" conducted for Survey Unit 9520-0006 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "InitialCharacterizationReport" and the "HistoricSite Assessment Supplement,"

c) Historic and current survey records review, d) Visual inspections and a "walk-down."

A review of the "Initialand Supplemental CharacterizationReports" as well as the previous "Classification Basis Summaries" was performed. Survey Unit 9520-0006 was initially part of Survey Unit 9520-0001, designated as the Southwest Site Storage Area, which was designated as Class 2 during the development of the LTP. The source documents, the "Connecticut Yankee Haddam Neck CharacterizationReport" and "Initial Classificationfor Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0.

Revision 0 3

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD The Southeast Site Storage area had a documented history as a radioactive materials storage area in which at least one (1) case of contamination to underlying soil had been recorded. Examples of some of the major events are provided below.

0 Plant Incident Report (PIR) 80-37 reported the discovery of three (3) discrete sources of elevated activity within the Southeast Site Storage area in of March 1980, along with other areas around the site. The ground level dose rate over one (1) spot was 3 millirem per hour (mr/hr) and, after digging below about one and a half feet (1 1/2 ft) of dirt, the contact reading was reported at about 400 mr/hr. The activity was found above a piece of uncontaminated construction rubble. Isotopic analysis of this discrete source identified Co-60 as the predominate isotope. Subsequent radiological surveys identified an additional discrete source which was also identified as predominately Co-60. Both these locations are believed to be associated with Survey Unit 9520-0001 based on a review of the 1980 survey maps. Records indicate that both elevated areas were removed.

  • In 1989, contaminated soil was found along the peninsula access road in both the upper and middle peninsula areas (Areas 9520 and 9530). The soil was subsequently removed, and was determined to have come from the area south of the 115 kV switchyard.

9 In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula which included Survey Areas 9520 and 9530.

Construction debris, including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, two (2) objects were also identified that had detectable radioactivity. The first was a piece of angle iron located in the water utility trench in Survey Area 9530-0004, and the second was a weathered drum containing turbine blades in Survey Area 9520-0002. To further characterize the extent of buried metallic objects, and to identify if any additional drums were present, an Electromagnetic (EM) survey was performed. The survey was conducted in three phases from February 2006 through March 2006 and identified over ninety (90) locations which were then further characterized by test pitting the areas. A total of ninety-four (94) test pits were completed to characterize subsurface materials.

In 2006, surface soil samples were collected to characterize the radiological condition of the surface soils following the decommissioning of buried commodities and systems. Cs-137 was the only gamma emitting radionuclide positively identified in concentrations meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).

The statistical quantities (i.e., mean, median and standard deviation) from the characterization are provided in Table 1.

Revision 0 4 Revision 0 4

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 1 - Sample Analysis Results from Characterization Soil Samples Cs-137 (pCi/g)

Minimum Value: 6.38E-03 Maximum Value: 9.94E-02 Mean: 4.49E-02 Median: 4.87E-02 Standard Deviation: 3.48E-02 In January of 2007, a FSS was designed and performed in this survey unit.

Systematic soil samples were taken in a triangular grid pattern from a random start location. This was combined with a scan survey of 50% of the surface and investigative soil samples at locations exceeding the scan alarm set-point.

Fifteen (15) systematic, four (4) biased and six (6) investigative surface soil samples where taken in Survey Unit 9520-0001. Of the twenty five (25) total samples taken, Cs-137 was positively identified (i.e. a result greater than two (2) standard deviations) in fifteen (15) soil samples. Other radionuclides were also positively identified by gamma spectroscopy and HTD analysis but at concentrations less than the screening criteria. Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the combined Operational DCGL for aggregates. A summary of the results for the statistical sample population are provided in Table 2.

Table 2 - Systematic Sample Analysis Results from Initial FSS Soil Samples Cs-137 (pCi/g)

Minimum Value: 1.34E-02 Maximum Value: 3.40E-01 Mean: 9.07E-02 Median: 6.06E-02 Standard Deviation: 8.12E-02 Revision 0 5

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Initial FSS results were documented in the Connecticut Yankee Final Status Survey Final Report - Phase V. Following the completion of FSS, the area was used to stockpile "radiologically clean" rubblized asphalt intended to be used to pave the ISFSI access road after final site grading was complete. In June of 2007, a surveillance survey was performed on the surface soils under the asphalt pile following the removal of the pile. Removal of the pile had removed additional soil below the original grade and exposed additional buried commodities. In addition, two elevated areas were identified at the same location. On-site analysis of soil samples indicated the presence of Co-60 and Cs-137 in sufficient concentrations to warrant remediation and a Class 1 designation for a new survey unit, 9520-0006, which was established around the area of concern that is located within the original boundary of 9520-0001.

Due to the reconfiguration of the survey unit boundaries, the remainder of Survey Unit 9520-0001 was re-subjected to FSS.

In Survey Unit 9520-0006, remediation was performed to remove the discovered buried pipe (broken pieces of vitreous clay piping believed to be part of the original sanitary leech, field that was decommissioned in 1979) and the identified soils exhibiting elevated activity. Following remediation, the area was scanned and six (6) post remediation surface soil samples were taken at the locations exhibiting the highest scan results. The results of the post remediation soil samples were used to design the Final Status Survey. The statistical quantities (i.e., mean, median and standard deviation) are provided in Table 3.

Table 3 - Sample Analysis Results for Post Remediation Soil Samples Cs-137 (pCi/g)

Minimum Value: 6.73E-02 Maximum Value: 1.68E+00 Mean: 4.95E-01 Median: 3.08E-01 Standard Deviation: 6.09E-01 No HTD radionuclides were positively identified (i.e. a result greater than two (2) standard deviations) in the initial FSS soil samples.

The FSS Engineer performed a visual inspection and walk-down during June 2007 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Revision 0 6

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Based upon the identification of radioactive material above the Derived Concentration Guideline Levels (DCGLs), and the need for radiological remediation, it was concluded that there was some probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 1 for Survey Unit 9520-0006 (refer to Section 3).

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS plan.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9520-0006 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Revision 0 7 Revision 0 7

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Equation I HTotal =Hsoi+HExistingGW +HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrern/yrFutureGw The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 4.

Revision 0 8

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 4 - Radionuclide Specific Base Case Soil DCGLs, Operational DCGLs and Required Minimum Detectable Concentrations (MDCs)

Radionuclide () Base Case Soil Operational DCGL Required MDC DCGL (pC/g) (2) (pC/g) (3) (pC/g) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.1 8E+0 I 6.96E-0 1 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+0 1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Te-99 1.26E+01 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-0 1 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-0 1 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O1 2.01E+01 1.18E+00 Pu-239/240 2.67E+O1 1.82E+01 1.07E+00 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered Hard to Detect (HTD)

(2) The Base Case Soil DCGL(s) are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to achieving seventeen (17) mrem/yr TEDE (4) The required MDC is equivalent to achieving one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed Revision 09 9

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Soil samples were collected in 2006 to establish the radiological condition of Survey Unit 9520-0001 for FSS and again in 2007 for post-remediation in Survey Unit 9520-0006. In both cases, Cs-137 was the only gamma emitting radionuclide reported in a concentration with the potential for exceeding the screening criteria. Other radionuclides were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) but at concentrations less than 5% of the Operational DCGL. Subsequently, Cs-137 was selected as the sole isotope of concern for this survey. The radiological survey data that was used for the survey design is provided in Table 3.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans". The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the sole radionuclide of concern in Survey Unit 9520-0006 (refer to Section 3). The previous characterization and FSS survey data did not identify any HTD radionuclides of concern for this survey unit. Subsequently, surrogate DCGLs were not required for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design. Radionuclide screening or de-selection is a process where the dose contribution from an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

Revision 0 10

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD As the survey unit is classified as a Class 1 surface soils area, and discrete, elevated areas of contamination was possible, the application of the Elevated Measurement Comparison (EMC) remained an option.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for FinalStatus Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 4.16 to maintain the relative shift (A/o) in the range of,1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing. Based upon a review of the historical information, the results of previous Characterization Surveys, the result of the previous FSS and the result of the post-remediation soil samples, the acquisition of additional judgmental surface soil samples from within this survey unit was deemed unnecessary.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status' Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 5.

Revision 0 I1I

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 5 - Sample Measurement Locations with Associated GPS .

Coordinates Designation Northing Easting 9520-0006-OOIF 236168.98 668761.18 9520-0006-002F 236168.98 668799.84 9520-0006-003F 236135.50 668741.85 9520-0006-004F 236135.50 668780.51 9520-0006-005F 236135.50 668819.17 9520-0006-006F 236135.50 668857.83 9520-0006-007F 236102.02 668722.52 9520-0006-008F 236102.02 668761.18 9520-0006-009F 236102.02 668799.84 9520-0006-OIOF 236102.02 668838.50 9520-0006-01IF 236102.02 668877.16 9520-0006-012F 236068.54 668780.51 9520-0006-013F 236068.54 668819.17 9520-0006-014F 236068.54 668857.83 9520-0006-015F 236035.06 668838.50 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 4.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of one (1) soil sample for "split sample" analysis by the off-site laboratory. This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.

The LTP specifies a required scanning coverage of 100% for outdoor Class 1 areas.

For this Class 1 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8.

Table 6 provides a synopsis of the survey design.

Revision 0 12

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 6 - Synopsis of the Survey Design Feature Design Criteria Basis Survey Unit Land Area 1,808 m' Based on AutoCAD-LT Type 1 and Type 2 errors were 15 0.05, sigma was 0.61 pCi/g, the Number of Measurements LBGR was set at 4.16 to maintain (15 systematic grid) Relative Shift in the range of I and 3 Grid Spacing 11.81 m Based on triangular grid Administratively set to achieve(1)

Operational DCGL 5.38 pCi/g Cs-137 sevente seventeen (17) ely t TEDE 1 1 mrem/yr The Operational DCGL meets the Soil Investigation Level 5.38 pCi/g Cs-137 LTP criteria for a Class 1 survey unit Scan Survey Area Approximately The LTP requires 100% area Coverage 100% of the area coverage for Class I survey units An instrument response greater than the Scan Scan Investigation Level MDC(DCGLEMC) Per BCY-HP-0239 Revision #0 of 2000 cpm plus ambient background (1) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

Revision 0 13

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under a FSS Plan package.

The package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

A single scan area was established that constituted approximately 100% of the surface area of Survey Unit 9520-0006. Grid lines, one (1) meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,470 counts per minute (cpm) up to 8,790 cpm.

The scan area was established and scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 100% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custodyfor FinalStatus Survey Samples."

Two (2) samples (9520-0006-007F and 9520-0006-010F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of one (1) sample (9520-0006-015F) for "split sample" analysis.

Revision 0 14

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD

6. SURVEY RESULTS All field survey activities were conducted between June 19, 2007 and July 02, 2007.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 7 provides an overview of the scan results for sample measurement locations.

Scan results for the entire survey unit are provided in Attachment 2.

Table 7 - Scan Results for Sample Measurement Locations Sample Highest Logged Action Level Measurement Reading > Action Level )

Location (2) (kcpm) (kcpm) 1 7.55 9.87 NO 2 7.56 10.64 NO 3 8.81 10.64 NO 4 9.15 10.03 NO 5 8.40 9.54 NO 6 7.96 10.67 NO 7 9.18 10.67 NO 8 7.54 9.65 NO 9 8.42 10.66 NO 11 8.42 10.13 NO 12 8.40 10.20 NO 13 7.44 8.47 NO 15 7.84 9.89 NO (1) The action level is based on a measurement in accordance with the FSS plan (MDC(DCGLEMc) of 2,000 cpm plus ambient background)

(2) Sample locations 9520-0006-002F and 9520-0006-006F were moved approximately two meters to the west of their established coordinate locations due to their close proximity to the eastern boundary of the survey unit.

The scan area, that comprised approximately 100% of the total surface area for the survey unit, was scanned for elevated radiation levels. The area was scanned in accordance with the FSS plan between June 29, 2007 and July 02, 2007.

Revision 0 15

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Thirty-four (34) scan strips were established in this survey unit. No elevated measurement locations were identified during scanning. Table 8 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

Table 8 - Scan Area Results Highest Action Logged Level () Elevated Reading Investigation Scan Strips Reading Identification (2) Sample (kcpm) (kcpm) 1 thru 10 9.08 10.79 None None I Ithru 20 8.61 10.58 None None 21 thru 30 8.98 10.58 None None 31 thru 34 8.93 10.16 None None (1) The action level is based on a measurement in accordance with the FSS plan (MDC(DCGLEMc) of 2,000 cpm plus ambient background)

(2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading.

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing and the associated field split using gamma spectroscopy. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). However, Cs-137 was the only gamma-emitting radionuclide reported in concentrations exceeding the de-selection criteria.

Cs-137 was identified in eleven (11) of the fifteen (15) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 9.

Revision 0 16

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 9 - Summary of Gamma Spectroscopy Results for Surface'Soil Samples Comprising the Statistical Sample Population Cs-137 Sample Number pCi/g 9520-0006-OOIF 5.30E-02 9520-0006-002F 7.36E-02 9520-0006-003F 2.35E-02 9520-0006-004F 1.77E-01 9520-0006-005F 8.93E-02 9520-0006-006F 1.07E-01 9520-0006-007F 1.11E-02 9520-0006-008F 6.05E-02 9520-0006-009F 0.OOE+00 9520-0006-01 OF 2.66E-01 9520-0006-OIF 1.11E-01 9520-0006-012F 0.OOE+00 9520-0006-013F 6.87E-01 9520-0006-014F 9.44E-02 9520-0006-015F 6.80E-02 The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. No HTD radionuclides were detected.

7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. One sample location was selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". Evaluation using the reported results for Cs-137 resulted in acceptable agreement between the field-split results at the selected location. The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachments 3 and 4 for data and data quality analysis results.

Revision 0 17

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD

8. INVESTIGATIONS AND RESULTS Although no elevated scan measurements were observed, six (6) additional judgmental surface soil samples were collected at the discretion of FSS supervision during the performance of FSS. These judgmental biased soil samples were analyzed for Cs-137 in accordance with the DQOs used during the survey design. Judgmental sample designations are listed with the GPS coordinates in Table 10.

Table 10 - Judgmental Sample Designations with Associated GPS Coordinates

'Designation Northing Easting 9520-0006-024-I 236127.59 668743.92 9520-0006-025-I 236108.41 668843.20 9520-0006-026-I 236131.87 .668808.84 9520-0006-027-I 236115.99 668841.76 9520-0006-028-I 236092.90 668822.91 9520-0006-029-I 236143.26 668773.04 (1) Judgmental sample numbers for this FSS commence with the designation 9520-0006-0241 as sample numbers 161 through 231 were assigned to soil samples taken during previous investigations.

The Judgmental sample results for the radionuclides of concern are provided in Table 11 below.

Table 11 - Investigative Sample Results Cs-137 Sample Number pCi/g 9520-0006-024-I 8.54E-02 9520-0006-025-I 1.06E-01 9520-0006-026-I 1.06E-01' 9520-0006-027-I 1.30E-01 9520-0006-028-I 1.39E-01 9520-0006-029-I 2.71E-02 Cs-137 was positively identified in all of the six (6) Judgmental samples taken.

All samples results were less than the Operational DCGL for Cs- 137.

Revision 0 18

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD

9. REMEDIATION AND RESULTS Radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to FSS. Remediation was performed to remove buried broken pieces of vitreous clay piping believed to be part of the original sanitary leech field that was decommissioned in 1979 and surrounding soils exhibiting elevated activity. All excavations were characterized and backfilled with "clean" fill prior to performing FSS. In the area where remediation occurred, the ground area is comprised of barren dirt with no vegetation, and the soils have been graded relatively flat to the corresponding elevation of the adjacent survey units. The results for Cs-137 following remediation were well below the Operational DCGL provided in Table 3.

Health Physics TSD BCY-HP-0078, "ALARA Evaluationof Soil Remediation in Support of Final Status Survey," determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment," for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 12.

Revision 0 19

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Table 12 - Basic Statistical Quantities for Cs-137 from the Final Status Survey ICs-137 pCi/g DCGLop: 5.38E+00 Minimum Value: 0.OOE+00 Maximum Value: 6.87E-01 Mean: 1.21E-01 Median: 7.36E-02 Standard Deviation: 1.71E-01 For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected and the difference between the mean and median was about 28% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 2.9 for Cs-137. All data, assessments, and graphical representations are provided in Attachment 4.

12. ANOMALIES No anomalies were noted.
13. CONCLUSION Survey Unit 9520-0006 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison was not required.

All identified radionuclides of concern were used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 1.

The dose contribution from soil is 0.38 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

Revision 0 20

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 2.38 mrem/yr TEDE. Therefore, Survey Unit 9520-0006 is acceptable for unrestricted release.

14. ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 21

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 1 (FIGURES)

Revision 0

/I Y-RefereCe CoOrdkiate Sysenm 6Whm .N*

- 667394.57 Nfhbng - 237370.20 / Easting

_-COMNIC77CU? RIVER--

Connecticut Yankee Atomic Power Company 9oo By Fiur 1Ste Map Wi th R eference To Survey Unit 9520- 0006 July2007 Woj0

0 25 50 43 Note SurveLocatdons 9520-00X-M02F&

9520-0006~

were relocated~-2 meters to the east of their orkima location Connecticut Yankee Atomic Power Company DaD By Survey Unit 9520-0096FinalStatus Survey Design July 2097 D. Wnitkown

000 25 50 87 Note Sufvey""Loain 9520-0006-002F&

9520-0006-006F were reocated~-2 meters to the east oftheir origial location Connecticut Yankee Atomic Power Company Date By Survey Unit9520-0006FinalStatus Survey Design

fVluftz 0 25 So

ýFca Note

-dlk AA-WIAS 41 00 Connecticut Yankee Atomic Power Company Survey Uit9520-0006 FSS JudgmentalSample Locations

Le-ved 139 0 25 50

. Feel

-ý4.085 Note

'I J%~u-uj Connecticut Yankee Atomic PowerCompany 9529-0006FSS JudgmentalSample Cs-137Results

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Revision 0

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0006 RELEASE RECORD Attachment 2 SCAN RESULTS @ SAMPLE LOCATIONS Survey Location Log Date Log Time Reading Alarm Level >Alarm E-600 SIN Probe SIN Level 9520-06-BL-00-01 -0 6/29/2007 7:15:00 7.87E+03 1107 1007 9520-06-SL-00-01-0 6/29/2007 7:16:00 7.55E+03 9.87E+03 1107 1007 9520-06-BL-00-02-0 6/29/2007 8:45:00 8.64E+03 1107 1007 9520-06-SL-00-02-0 6/29/2007 8:46:00 7.56E+03 1.06E+04 1107 1007 9520-06-BL-00-03-0 6/29/2007 7:22:00 8.64E+03 1107 1007 9520-06-SL-00-03-0 6/29/2007 7:23:00 8.81 E+03 1.06E+04 1107 1007 9520-06-BL-00-04-0 6/29/2007 7:24:00 8.03E+03 1107 1007 9520-06-SL-00-04-0 6/29/2007 7:24:00 9.15E+03 1.OOE+04 1107 1007 9520-06-BL-00-05-0 6/29/2007 7:25:00 7.54E+03 1107 1007 9520-06-SL-00-05-0 6/29/2007 7:26:00 8.40E+03 9.54E+03 1107 1007 9520-06-BL-00-06-0 6/29/2007 8:50:00 8.67E+03 1107 1007 9520-06-SL-00-06-0 6/29/2007 8:51:00 7.96E+03 1.07E+04 1107 1007 9520-06-BL-00-07-0 6/29/2007 7:30:00 8.67E+03 1107 1007 9520-06-SL-00-07-0 6/29/2007 7:31:00 9.18E+03 1.07E+04 1107 1007 9520-06-BL-00-08-0 6/29/2007 7:33:00 7.65E+03 1107 1007 9520-06-SL-00-08-0 6/29/2007 7:34:00 7.54E+03 9.65E+03 1107 1007 9520-06-BL-00-09-0 6/29/2007 7:35:00 8.66E+03 1107 1007 9520-06-SL-00-09-0 6/29/2007 7:35:00 8.42E+03 1.07E+04 1107 1007 9520-06-BL-00-10-0 6/29/2007 7:37:00 8.13E+03 1107 1007 9520-06-SL-00-10-0 6/29/2007 7:38:00 8.42E+03 1.01 E+04 1107 1007 9520-06-BL-00-11-0 6/29/2007 7:40:00 8.20E+03 1107 1007 9520-03-SL-00-11-0 6/29/2007 7:41:00 8.40E+03 1.02E+04 1107 1007 9520-06-BL-00-12-0 6/29/2007 7:42:00 6.47E+03 1107 1007 9520-06-SL-00-12-0 6/29/2007 7:43:00 7.44E+03 8.47E+03 1107 1007 9520-06-BL-00-13-0 6/29/2007 7:43:00 7.89E+03 1107 1007 9520-06-SL-00-13-0 6/29/2007 7:44:00 7.84E+03 9.89E+03 1107 1007 9520-06-BL-00-14-0 6/29/2007 7:45:00 7.71 E+03 1107 1007 9520-06-SL-00-14-0 6/29/2007 7:46:00 8.12E+03 9.71 E+03 1107 1007 9520-06-BL-00-15-0 6/29/2007 7:47:00 7.79E+03 1107 1007 9520-06-SL-00-15-0 6/29/2007 7:48:00 8.17E+03 9.79E+03 1107 1007 REV 0 Page 1 of 1

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0006 Release Record Attachment 2 Survey Location Log Date Log Time Reading Alarm Level >Alarm Lvi E-600 SIN Probe SIN 9520-06-BC-01-01-0 6/29/2007 10:37:00 7.88E+03 1107 1007 9520-06-SC-01-01-0 6/29/2007 10:49:00 8.31 E+03 9.88E+03 1107 1007 9520-06-BC-01-02-0 6/29/2007 10:51:00 8.64E+03 1107 1007 9520-06-SC-01-02-0 6/29/2007 11:05:00 8.97E+03 1.06E+04 1107 1007 9520-06-BC-01-03-0 6/29/2007 11:08:00 8.79E+03 1107 1007 9520-06-SC-01-03-0 6/29/2007 11:16:00 9.08E+03 1.08E+04 1107 1007 9520-06-BC-01-04-0 6/29/2007 11:17:00 8.03E+03 1107 1007 9520-06-SC-01-04-0 6/29/2007 11:26:00 8.64E+03 1.OOE+04 1107 1007 9520-06-BC-01-05-0 6/29/2007 11:29:00 7.54E+03 1107 1007 9520-06-SC-01-05-0 6/29/2007 11:40:00 7.58E+03 9.54E+03 1107 1007 9520-06-BC-01-06-0 6/29/2007 11:42:00 7.33E+03 1107 1007 9520-06-SC-01-06-0 6/29/2007 12:11:00 7.97E+03 9.33E+03 1107 1007 9520-06-BC-01-07-0 7/2/2007 7:37:00 8.68E+03 1107 1007 9520-06-SC-01-07-0 7/2/2007 7:45:00 8.45E+03 1.07E+04 1107 1007 9520-06-BC-01-08-0 7/2/2007 7:48:00 7.68E+03 1107 1007 9520-06-SC-01-08-0 7/2/2007 7:54:00 7.76E+03 9.68E+03 1107 1007 9520-06-BC-01-09-0 7/2/2007 7:56:00 8.66E+03 1107 1007 9520-06-SC-01-09-0 7/2/2007 8:07:00 8.96E+03 1.07E+04 1107 1007 9520-06-BC-01-10-0 7/2/2007 8:08:00 8.13E+03 1107 1007 9520-06-SC-01-10-0 7/2/2007 8:20:00 8.50E+03 1.01 E+04 1107 1007 9520-06-BC-01-11-0 7/2/2007 8:21:00 8.OOE+03 1107 1007 9520-06-SC-01-11-0 7/2/2007 8:30:00 7.99E+03 1.OOE+04 1107 1007 9520-06-BC-01-12-0 7/2/2007 8:32:00 8.58E+03 1107 1007 9520-06-SC-01-12-0 7/2/2007 8:39:00 8.52E+03 1.06E+04 1107 1007 9520-06-BC-01-13-0 7/2/2007 8:40:00 7.99E+03 1107 1007 9520-06-SC-01 0 7/2/2007 8:49:00 8.43E+03 9.99E+03 1107 1007 9520-06-BC-01-14-0 7/2/2007 9:56:00 7.71 E+03 1107 1007 9520-06-SC-01-14-0 7/2/2007 10:05:00 8.07E+03 9.71 E+03 1107 1007 9520-06-BC-01-15-0 7/2/2007 10:06:00 8.35E+03 1107 1007 9520-06-SC-01-15-0 7/2/2007 10:16:00 8.25E+03 1.04E+04 1107 1007 9520-06-BC-01-16-0 7/2/2007 10:16:00 8.23E+03 1107 1007 9520-06-SC-01-16-0 7/2/2007 10:23:00 8.51E+03 1.02E+04 1107 1007 9520-06-BC-01-17-0 7/2/2007 10:24:00 8.28E+03 1107 1007 9520-06-SC-01 0 7/2/2007 10:31:00 8.60E+03 1.03E+04 1107 1007 9520-06-BC-01-18-0 7/2/2007 10:32:00 7.89E+03 1107 1007 9520-06-SC-01-18-0 7/2/2007 10:38:00 8.26E+03 9.89E+03 1107 1007 9520-06-BC-01-19-0 7/2/2007 10:41:00 7.99E+03 1107 1007 9520-06-SC-01-19-0 7/2/2007 10:46:00 8.61 E+03 9.99E+03 1107 1007 9520-06-BC-01-20-0 7/2/2007 10:47:00 7.99E+03 1107 1007 9520-06-SC-01-20-0 7/2/2007 10:52:00 8.40E+03 9.99E+03 1107 1007 9520-06-BC-01-21-0 7/2/2007 10:54:00 8.58E+03 1107 1007 9520-06-SC-01-21-0 7/2/2007 11:01:00 8.43E+03 1.06E+04 1107 1007 REV 0 Page 1 of 2

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0006 Release Record Attachment 2 Survey Location Log Date Log Time Reading Alarm Level >Alarm Lvl E-600 SIN Probe SIN 9520-06-BC-01-22-0 7/2/2007 11:02:00 7.95E+03 1107 1007 9520-06-SC-01-22-0 7/2/2007 11:08:00 8.98E+03 9.95E+03 1107 1007 9520-06-BC-01-23-0 7/2/2007 11:09:00 8.28E+03 1107 1007 9520-06-SC-01-23-0 7/2/2007 11:17:00 8.07E+03 1.03E+04 1107 1007 9520-06-BC-01-24-0 7/2/2007 11:17:00 7.46E+03 1107 1007 9520-06-SC-01-24-0 7/2/2007 11:24:00 8.24E+03 9.46E+03 1107 1007 9520-06-BC-01-25-0 7/2/2007 11:25:00 7.98E+03 1107 1007 9520-06-SC-01-25-0 7/2/2007 11:31:00 7.79E+03 9.98E+03 1107 1007 9520-06-BC-01-26-0 7/2/2007 11:32:00 7.86E+03 1107 1007 9520-06-SC-01-26-0 7/2/2007 11:38:00 8.20E+03 9.86E+03 1107 1007 9520-06-BC-01-27-0 7/2/2007 13:08:00 7.50E+03 1107 1007 9520-06-SC-01-27-0 7/2/2007 13:19:00 8.24E+03 9.50E+03 1107 1007 9520-06-BC-01-28-0 7/2/2007 13:20:00 7.71E+03 1107 1007 9520-06-SC-01-28-0 7/2/2007 13:28:00 8.20E+03 9.71E+03 1107 1007 9520-06-BC-01-29-0 7/2/2007 13:29:00 7.65E+03 1107 1007 9520-06-SC-01-29-0 7/2/2007 13:32:00 8.46E+03 9.65E+03 1107 1007 9520-06-BC-01-30-0 7/2/2007 13:34:00 7.85E+03 1107 1007 9520-06-SC-01-30-0 7/2/2007 13:38:00 7.97E+03 9.85E+03 1107 1007 9520-06-BC-01-31-0 7/2/2007 13:39:00 8.16E+03 1107 1007 9520-06-SC-01-31-0 7/2/2007 13:42:00 8.93E+03 1.02E+04 1107 1007 9520-06-BC-01-32-0 7/2/2007 13:42:00 7.96E+03 1107 1007 9520-06-SC-01-32-0 7/2/2007 13:47:00 8.27E+03 9.96E+03 1107 1007 9520-06-BC-01-33-0 7/2/2007 13:49:00 7.84E+03 1107 1007 9520-06-SC-01-33-0 7/2/2007 13:54:00 8.73E+03 9.84E+03 1107 1007 9520-06-BC-01-34-0 7/2/2007 13:55:00 7.74E+03 1107 1007 9520-06-SC-01-34-0 7/2/2007 14:03:00 8.02E+03 9.74E+03 1107 1007 REV 0 Page 2 of 2

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

Revision 0

General Narrative Page 1 of 76

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 188898 SDG: MSR#07-0197 July 06, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on June 30, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 188898001 9520-0006-OOIF 188898002 9520-0006-002F 188898003 9520-0006-003F 188898004 9520-0006-004F 188898005 9520-0006-005F 188898006 9520-0006-006F 188898007 9520-0006-007F 188898008 9520-0006-008F 188898009 9520-0006-009F 188898010 9520-0006-01OF 188898011 9520-0006-01 IF 188898012 9520-0006-012F 188898013 9520-0006-013F 188898014 9520-0006-014F 188898015 9520-0006-015F 188898016 9520-0006-015FS Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

GEL Laboratories Pfige 2 9*MBM0712 Charleston, SC 29417 2040 Savage Road Charlestn, SC 29407 P843.555.8171 F843.766.1178 www.gal.com

Analytical Request Fourteen soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl MJones Project Manager GEL Laboratories Pfige 3 PIM?910712 Chaleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.556.8171 F843.756.1178 www.gel~corn

List of current GEL Certifications as of 06 July 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01 151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 Page 4 of 76

M Chain of Custody and Supporting Documentation Page 5 of 76

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-00156 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 "*

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Clyde Newson 860-267- 3157 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 <

843 556 8171. Attn. Cheryl Jones V)

Priority: 0 30 D. II 14 D. Z 7 D. F1 3 D. Container C ,

Sample Size-Sample Designation Date Time Media Type &Type Comment. Preservation Lab Sample ID Code Code Code 9520-0006-001F 6/29/07 0755 TS G BP X 9520-0006-002F 6/29/07 0920 TS G BP X 9520-0006-003 F 6/29/07 0803 TS G BP X 9520-0006-004F 6/29/07 0805 TS G BP X 9520-0006-005F 6/29/07 0810 TS G BP X 9520-0006-006F 6/29/07 0915 TS G BP X 9520-0006-007F 6/29/07 0820 TS G BP X 9520-0006-008F 6/29/07 0825 TS G BP X 9520-0006-009F 6/29/07 0830 TS G BP X 9520-0006-OIOF 6/29/07 0835 TS G BP X 9520-0006-011F 6/29/07 0910 TS G BP X NOTES: PO #: 002332 MSR#: 07- 0197 SSWP FSSP 9520-0006 Z LTP QA [] Radwaste QA E] Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.

EDUPS C Cii-tndv Seanlpd9

1) Relinqui y .y D te/Time 2) dByf .Date/Time EHand Custody Seal V

(-/L C7 S-0 31/10 -7 30 E E] Other Intact?

3) Relinquished]3 / Date/Time 4) Keceived By Date/Time Y N]

Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-00157 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Clyde Newson 860-267- 3157 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 <

843 556 8171. Attn. Cheryl Jones V)

Priority: 0 30 D. 0 14 D. M 7 D. 3 D. C Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9520-0006-012F 6/29/07 0845 TS G BP X 9520-0006-013F 6/29/07 0840 TS G BP X 9520-0006-014F 6/29/07 0850 TS G BP X 9520-0006-015F 6/29/07 0855 TS G BP X 9520-0006-015FS 6/29/07 0855 TS G BP X NOTES: PO #: 002332 MSR #: 07- 0197 SSWP FSSP 9520-0006 M LTP QA ] Radwaste QA F] Non QA Samples Shipped Via: Internal Container E Fed Ex Temp.: __ Deg.

El UPS C Re__eCII.tndv Sealed?

1) Relinquis ,ate/Time 2) Re eivedBy \-7. ,Daje/Time El Hand Custody Seal ip.tLý1b- "? ,. O L0/'/07Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time BillofLadingY_ _ _N Bill of Lading # ,!
5) Relinquished By Date/Time 6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List.

Date/Time Received': / " 7- J 0 SDG#: a. 3C,. ,-67 Work Order Number: \% .

Shipping Ccftainer ID:- 3 T* ?*/ 7V .-. Chain of Custody#.

71533-2 .' 7 5,

1. Custody Seals odshipping container intact?:,. Yes *jNo [ ]
2. Custody Seals dated and signed? Yes ' N
3. Chain-of-Custoyy record present?

" Yes 1*.No [

Cooler tmperature

5. Vermiculite/packing materials is: . " Wet JDry -"
o. Number of samples in shipping container: I * " ",." " "
7. Sample holding times exceeded? Yes [I No f

.. Samples have:

?<tap-hazard labels

...4:%itody seals 25::Iapropriate Sample label:

9. Samplesle - _ a t

.. *in good condition leaking broken ." "" have air bubbles

10. Were any anomalies identified in sample receipt? Yes [J No l.. *.Description of anomalies (include sample numbers):

$ample. Custodian/Laboratory.

Telephoned to: On By

JM , Laboratories LLG SAMPLERECEIPT & REVIEW.FORM Client: 74 ],J - SDGIARCOC/Work Order: IC 6

  • C Received By: Date Received:3 Suspected Hazard. Information *If Counts > x2 area background on samples not marked "radioactive",

SuspectedHazard_______________actxthe Radiation Safety Group of further investigation.

COC/Samples marked as radioactive? _ Yaximum Counts Observed*: C ,

Classified Radioactive II by RSO?

CQC/Samples marked containing PCBs? __

Shipped as a DOT Hazardous? H d Class Shipped: UN#:

Samples identified as Foreign Soil? _ _ _*_ ___

Sample Receipt Criteria . 0 Comments/Qualifiers (Required for Non-Conforming Items)

Circle Applicable:

1 Shipping containers received intact and seals broken damaged container leaking container other (describe) sealed?

Preservation Method:

2 Samples. requiring cold preservation ice bags - blue ice dry ice none other (describe) within (4+1- 2 C)?

Chain of custody documents included Circle Applicable:

4 Sample containers intactand sealed? 'seals broken damaged container leaking container other (describe)

. ..Smpl ples -r--iin s requirin

_Sam chemica" a -l'_

'Ichemi.cn I "  : ID's, containers affected and observed pMi:

/ .Sample preservation at proper pH? If Preservation added, Lotl:

6 VOA vials free of headspace (defined/ pe IDp containe affected:

as < 6mm bubble)?

.(f , immediately deliver to Volatiles laboratory) 7 Are Encore containers present?

id'sI and tests affected:

8 Samples, received within holding time?

Sampe COCmath IDa o IDs ~Sample ID's and containers affected:

bottles?

1Date & time on COC match date & Sample ID's affected:

time on bottles?

Number of containers received match Sample ID's affected:

number indicated on COC?

COC form-is properly signed in relinquished/received sections?

Comments:

7  ? 33d-I '791 k'M.. M)rve:Iiil 'o Dat J *V '/.

JRM (or PMA) review: initials Date U k, d_ý

"-/L O-t qa -7c,;-->

9520-0006

Subject:

9520-0006 From: "Rick E. Gault" <Gault@CYAPCO.com>

Date: Fri, 29 Jun 2007 14:59:37 -0400 To: "Cheryl Jones" <cj @gel.com>

Cheryl; We're sending 16 samples under MSR 07-0197 to GEL today. All of the samples have a 7 day TAT request. It is acceptable for GEL to use the traced/untraced Tc-99 process for these quick TAT requests. See attached COC for requested analyses.

Rick Gault CYAPCO 860-267-3903 Content-Description: COC 07_0156_0157.pdf COC 07 0156_0157.pdf. Content-Type: application/octet-streamr Content-Encoding: base64 1of 1 b- 6/29/2007 3:06 PM

Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound c Result is less than value reported

> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B" Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories Pfige I fCP 2 Charleston, SC 29417 17 2040 Savage Road Charleston, SC 29407 P843.556.8171 F843.7661178 www, goh~com

RADIOLOGICAL ANALYSIS Page 12 of76

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 188898 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 648282 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01 OF 1201369359 Method Blank (MB) 1201369360 188898007(9520-0006-007F) Sample Duplicate (DUP) 1201369361 188898007(9520-0006-007F) Matrix Spike (MS) 1201369362 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 15.:

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 13 of 76

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 188898007 (9520-0006-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to a zero critical level caused by their being counted on zero background detectors.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 14 of 76

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 648283 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01 OF 1201369363 Method Blank (MB) 1201369364 188898007(9520-0006-007F) Sample Duplicate (DUP) 1201369365 188898007(9520-0006-007F) Matrix Spike (MS) 1201369366 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 15.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 188898007 (9520-0006-007F).

QC Information All of the QC samples met the required acceptance limits.

Page 15 of 76

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201369363 (MB), 1201369365 (9520-0006-007F) and 188898010 (9520-0006-010F) were recounted due to a zero critical level caused by being counted on zero background detectors.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 648286 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Page 16 of 76

Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-OIOF 1201369372 Method Blank (MB) 1201369373 188898007(9520-0006-007F) Sample Duplicate (DUP) 1201369374 188898007(9520-0006-007F) Matrix Spike (MS) 1201369375 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898007 (9520-0006-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from Page 17 of 76

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 648306 Prep Batch Number: 648116 Sample ID Client ID 188898001 9520-0006-OO1F 188898002 9520-0006-002F 188898003 9520-0006-003F 188898004 9520-0006-004F 188898005 9520-0006-005F 188898006 9520-0006-006F 188898007 9520-0006-007F 188898008 9520-0006-008F 188898009 9520-0006-009F 188898010 9520-0006-01OF 188898011 9520-0006-01 IF 188898012 9520-0006-012F 188898013 9520-0006-013F 188898014 9520-0006-014F 188898015 9520-0006-015F 188898016 9520-0006-015FS 1201369415 Method Blank (MB) 1201369416 188898001(9520-0006-00IF) Sample Duplicate (DUP) 1201369417 Laboratory Control Sample (LCS)

Page 18 of 76

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898001 (9520-0006-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201369416 (9520-0006-001F) and 188898001 (9520-0006-001F), did not meet the relative percent difference requirement for Ac-228 and Cs- 137, however they do meet the relative error ratio requirement with value of 1.228 for Ac-228 and 1.480 for Cs-137.

Page 19 of 76

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to a high counting uncertainty. Bismuth-212 1201369416 U' Data rejected due to high peak width. Potassium-40 1201369415 UI Data rejected due to low abundance. Bismuth-212 188898001 188898003 188898004 188898005 188898008 188898013 188898016 Cesium- 134 188898002 188898004 188898008 188898012 UI Data rejected due to no valid peak. Cesium- 137 188898009 188898012 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 648289 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Page 20 of 76

Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-OIOF 1201369376 Method Blank (MB) 1201369377 188898010(9520-0006-01OF) Sample Duplicate (DUP) 1201369378 188898010(9520-0006-OlOF) Matrix Spike (MS) 1201369379 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 188898010 (9520-0006-01OF).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201369376 (MB) and 1201369377 (9520-0006-010F) were recounted due to a negative result greater than three times the error.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Page 21 of 76

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 647974 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-OIOF 1201368673 Method Blank (MB) 12013,68674 188898007(9520-0006-007F) Sample Duplicate (DUP) 1201368675 188898007(9520-0006-007F) Matrix Spike (MS) 1201368676 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 22 of 76

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898007 (9520-0006-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Revised data is being reported for samples 1201368674 (9520-0006-007F), 188898007 (9520-0006-007F) and 188898010 (9520-0006-01 OF). After receiving fax data the client requested that the samples be recounted due to suspected false positives. Recounted samples had results less than the MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 23 of 76

Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 648290 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01OF 1201369380 Method Blank (MB) 1201369381 188898010(9520-0006-010F) Sample Duplicate (DUP) 1201369382 188898010(9520-0006-01OF) Matrix Spike (MS) 1201369383 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard, Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 4.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898010 (9520-0006-010F).

QC Information All of the QC samples met the required acceptance limits.

Page 24 of 76

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 649056 Prep Batch Number: 648281 Dry Soil Prep GL-RAD-A-021 Batch Number: 648116 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01OF 1201370979 Method Blank (MB) 1201370980 188898010(9520-0006-01 OF) Sample Duplicate (DUP) 1201370981 188898010(9520-0006-010F) Matrix Spike (MS) 1201370982 Laboratory Control Sample (LCS)

Page 25 of 76

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898010 (9520-0006-010F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Page 26 of 76

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 647976 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01 OF 1201368682 Method Blank (MB) 1201368683 188898010(9520-0006-01OF) Sample Duplicate (DUP) 1201368684 188898010(9520-0006-010F) Matrix Spike (MS) 1201368685 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 15.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898010 (9520-0006-010F).

QC Information All of the QC samples met the required acceptance limits.

Page 27 of 76

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis The batch was recounted due to a high background.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid AIl,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 647980 Sample ID Client ID 188898007 9520-0006-007F 188898010 9520-0006-01OF 1201368693 Method Blank (MB) 1201368694 188898007(9520-0006-007F) Sample Duplicate (DUP) 1201368695 188898007(9520-0006-007F) Matrix Spike (MS) 1201368696 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 9.

Page 28 of 76

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188898007 (9520-0006-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all Page 29 of 76

of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date: . k ý '2/6 /167 Page 30 of 76

SAMPLE DATA

SUMMARY

Page 31 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-0197 GEL Work Order: 188898 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 32 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-00IF Project: YANK01204 Sample ID: 188898001 Client ID: YANK00I Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 1.47%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.790 +/-0.181 0.0568 +/-0.181 0.114 pCi/g MJH1 07/03/07 1402 648306 1 Americium-241 U 0.0695 +/-0.107 0.0882 +/-0.107 0.176 pCi/g Bismuth-212 UI 0.00 +/-0.252 0.191 +/-0.252 0.382 pCi/g Bismuth-214 0.605 +/-0.115 0.0324 +/-0.115 0.0647 pCi/g Cesium-134 U 0.028 +/-0.0325 0.0227 +/-0.0325 0.0454 pCi/g Cesium- 137 0.053 +/-0.0415 0.0165 +/-0.0415 0.0329 pCi/g Cobalt-60 U 0.0365 +/-0.0236 0.020 +/-0.0236 0.040 pCi/g Europium- 152 U -0.0153 +/-0.0903 0.0529 +/-0.0903 0.106 pCi/g Europium- 154 U -0.0106 +/-0.0675 0.0578 +/-0.0675 0.116 pCi/g Europium- 155 U 0.0515 +/-0.0609 0.0555 +/-0.0609 0.111 pCi/g Lead-212 0.703 +/-0.083 0.0284 +/-0.083 0.0568 pCi/g Lead-214 0.607 +/-0.0952 0.0346 +/-0.0952 0.0692 pCi/g Manganese-54 U 0.00726 +/-0.0251 0.0193 +/-0.0251 0.0385 pCi/g Niobium-94 U -0.00582 +/-0.019 0.0163 +/-0.019 0.0325 pCi/g Potassium-40 10.4 +/-1.02 0.169 +/-1.02 0.338 pCi/g Radium-226 0.605 +/-0.115 0.0324 +/-0.115 0.0647 pCi/g Silver-108m U-0.000452 +/-0.0191 0.0166 +/-0.0191 0.0331 pCi/g Thallium-208 0.228 +/-0.0478 0.0176 +/-0.0478 0.0352 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

Page 33 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Ce-rtificat nf Ana1v~i~

&llINA Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-001F Project: YANK01204 Sample ID: 188898001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 34 of 76

GEL LABORATORIES LLC 2040 Savage Road. Charleston SC 29407 - (843) 556-8171 - www.gel.com rf Ainal vvic

.L Company : Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-002F Proiect: YANK01204 Sample ID: 188898002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 3.54%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.634 +/-0.159 0.0643 +/-0.159 0.129 pCi/g MJHI 07/03/07 1403 648306 1 Americium-241 U 0.0473 +/-0.109 0.0947 +/-0.109 0.189 pCi/g Bismuth-212 0.463 +/-0.258 0.130 +/-0.258 0.261 pCi/g Bismuth-214 0.581 +/-0.0982 0.032 +/-0.0982 0.0639 pCi/g Cesium-134 UI 0.00 +/-0.0327 0.021 +/-0.0327 0.0419 pCi/g Cesium-137 0.0736 +/-0.0371 0.0182 +/-0.0371 0.0363 pCi/g Cobalt-60 U -0.00111 +/-0.021 0.0177 +/-0.021 0.0353 pCi/g Europium-152 U 0.0325 +/-0.0547 0.0468 +/-0.0547 0.0935 pCi/g Europium-154 U -0.00523 +/-0.0735 0.053 +/-0.0735 0.106 pCi/g Europium-155 U -0.0131 +/-0.0574 0.0518 +/-0.0574 0.104 pCi/g Lead-212 0.656 +/-0.0718 0.0256 +/-0.0718 0.0511 pCi/g Lead-214 0.589 +/-0.0922 0.0342 +/-0.0922 0.0684 pCi/g Manganese-54 U 0.009 +/-0.0223 0.0196 +/-0.0223 0.0392 pCi/g Niobium-94 U 0.00444 +/-0.0182 0.0161 +/-0.0182 0.0322 pCi/g Potassium-40 10.7 +/-1.14 0.167 +/-1.14 0.334 pCi/g Radium-226 0.581 +/-0.0982 0.032 +/-0.0982 0.0639 pCi/g Silver-108m U-0.000543 +/-0.0181 0.0156 +/-0.0181 0.0312 pCi/g Thallium-208 0.181 +/-0.0438 0.0149 +/-0.0438 0.0298 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 35 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-002F Project: YANK01204 Sample ID: 188898002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 36 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-003F Proiect: YANKO 1204 Sample ID: 188898003 Client ID: YANKOO Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 1.59%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.858 +/-0.205 0.0697 +/-0.205 0.139 pCi/g MJHI 07/03/07 1403 648306 1 Americium-241 U 0.013 -+/-0.0977 0.0831 +/-0.0977 0.166 pCi/g Bismuth-212 UI 0.00 +/-0.247 0.177 +/-0.247 0.353 pCi/g Bismuth-214 0.661 +/-0.107 0.0339 +/-0.107 0.0678 pCi/g Cesium-134 U 0.0186 -+/-0.0268 0.0246 +/-0.0268 0.0492 pCi/g Cesium-137 U 0.0235 -+/-0.0249 0.0226 +/-0.0249 0.0451 pCi/g Cobalt-60 U 0.00067 -+/-0.0258 0.0219 +/-0.0258 0.0438 pCi/g Europium-152 U -0.0427 -+/-0.0937 0.0525 +/-0.0937 0.105 pCi/g Europium-154 U -0.0515 -+/-0.0755 0.0603 +/-0.0755 0.121 pCi/g Europium-155 U 0.0869 -+/-0.067 1 0.0583 +/-0.0671 0.117 pCi/g Lead-212 0.707 -+/-0.079 1 0.0292 +/-0.0791 0.0583 pCi/g Lead-214 0.530 -+/-0.0963 0.0391 +/-0.0963 0.0782 pCi/g Manganese-54 U 0.00211 -+/-0.0223 0.0195 +/-0.0223 0.039 pCi/g Niobium-94 U -0.0123 -+/-0.0203 0.0173 +/-0.0203 0.0345 pCi/g Potassium-40 12.4 +/-1.13 0.153 +/-1.13 0.305 pCilg Radium-226 0.661 +/-0. 107 0.0339 +/-0.107 0.0678 pCi/g Silver-108m U -0.00953 -+/-0.01 86 0.0161 +/-0.0186 0.0322 pCi/g Thallium-208 0.229 -+/-0.0462 0.0202 +/-0.0462 0.0404 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 37 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-003F Project: YANK01204 Sample ID: 188898003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 38 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-004F Proiect: YANK01204 Sample ID: 188898004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 3.19%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.802 +/-0.209 0.0808 +/-0.209 0.162 pCi/g MJHI 07/03/07 1403 648306 1 Americium-241 U 0.0424 +/-0.0488 0.0422 +/-0.0488 0.0844 pCi/g Bismuth-212 UI 0.00 +/-0.369 0.278 +/-0.369 0.555 pCi/g Bismuth-214 0.507 +/-0.127 0.0476 +/-0.127 0.0952 pCi/g Cesium- 134 UI 0.00 +/-0.0649 0.0339 +/-0.0649 0.0677 pCi/g Cesium-137 0.177 +/-0.0506 0.0297 +/-0.0506 0.0594 pCi/g Cobalt-60 U -0.00523 +/-0.0324 0.0268 +/-0.0324 0.0536 pCi/g Europium-152 U 0.0251 +/-0.103 0.0643 +/-0.103 0.129 pCi/g Europium-154 U 0.0053 +/-0.109 0.0797 +/-0.109 0.159 pCi/g Europium-155 U 0.0966 +/-0.0832 0.0695 +/-0.0832 0.139 pCi/g Lead-212 0.711 +/-0.099 0.0378 +/-0.099 0.0755 pCi/g Lead-214 0.647 +/-0.135 0.0486 +/-0.135 0.0971 pCi/g Manganese-54 U-0.000516 +/-0.0324 0.0277 +/-0.0324 0.0553 pCi/g Niobium-94 U 0.00727 +/-0.0317 0.027 +/-0.0317 0.054 pCi/g Potassium-40 10.1 +/-1.37 0.223 +/-1.37 0.445 pCi/g Radium-226 0.507 +/-0.127 0.0476 +/-0.127 0.0952 pCi/g Silver-108m U 0.00166 +/-0.0282 0.0246 +/-0.0282 0.0491 pCi/g Thallium-208 0.250 +/-0.0566 0.024 +/-0.0566 0.048 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 39 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-004F Proiect: YANK01204 Sample ID: 188898004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 40 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-005F Proiect: YANK01204 Sample ID: 188898005 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 4.12%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.683 +/-0.200 0.0591 +/-0.200 0.118 pCi/g MJH1 07/03/07 1404 648306 1 Americium-241 U -0.0213 +/-0.103 0.0851 +/-0.103 0.170 pCi/g Bismuth-212 UI 0.00 +/-0.247 0.196 +/-0.247 0.392 pCi/g Bismuth-214 0.5ý74 +/-0.108 0.0368 +/-0.108 0.0736 pCi/g Cesium-134 U 0.030 +/-0.0382 0.0226 +/-0.0382 0.0451 pCi/g Cesium-137 0.0893 +/-0.0369 0.0204 +/-0.0369 0.0407 pCi/g Cobalt-60 U -0.013 +/-0.0243 0.0192 +/-0.0243 0.0383 pCi/g Europium-152 U -0.0455 +/-0.0818 0.0495 +/-0.0818 0.0989 pCi/g Europium-154 U 0.0705 +/-0.0689 0.0651 +/-0.0689 0.130 pCi/g Europium-ISS U -0.00174 +/-0.0585 0.0526 +/-0.0585 0.105 pCi/g Lead-212 0.721 +/-0.0831 0.0285 +/-0.0831 0.0569 pCi/g Lead-214 0.601 +/-0.0966 0.0349 +/-0.0966 0.0698 pCi/g Manganese-54 U 0.0167 +/-0.0214 0.0195 +/-0.0214 0.039 pCi/g Niobium-94 U -0.00681 +/-0.0253 0.0184 +/-0.0253 0.0369 pCi/g Potassium-40 9.21 +/-1.00 0.199 . +/-1.00 0.397 pCi/g Radium-226 0.574 +/-0.108 0.0368 +/-0.108 0.0736 pCi/g Silver-108m U -0.00324 +/-0.0194 0.0164 +/-0.0194 0.0329 pCi/g Thallium-208 0.244 +/-0.0425 0.018 +/-0.0425 0.036 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 41 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-005F Project: YANK01204 Sample ID: 188898005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 42 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com E7prtifientit of An2lv i Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-006F Project: YANK01204 Sample ID: 188898006 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 2.05%

Parameter Qualifier- Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.595 +/-0.172 0.0627 +/-0.172 0.125 pCi/g MJH1 07/03/07 1404 648306 1 Americium-241 U -0.0199 +/-0.109 0.0899 +/-0.109 0.180 pCi/g Bismuth-212 0.506 +/-0.257 0.138 +/-0.257 0.276 pCi/g Bismuth-214 0.549 +/-0.101 0.0374 +/-0.101 0.0748 pCi/g Cesium-134 U 0.0337 +/-0.0228 0.0221 +/-0.0228 0.0441 pCi/g Cesium-137 0.107 +/-0.0308 0.0173 +/-0.0308 0.0346 pCi/g Cobalt-60 U 0.0146 +/-0.0304 0.0193 +/-0.0304 0.0386 pCi/g Europium- 152 U -0.0216 +/-0.0613 0.0467 +/-0.0613 0.0934 pCi/g Europium-154 U 0.0454 +/-0.0606 0.0554 +/-0.0606 0.111 pCi/g Europium-155 U 0.0246 +/-0.0608 0.0567 +/-0.0608 0.113 pCi/g Lead-212 0.597 +/-0.0695 0.0252 +/-0.0695 0.0504 pCi/g Lead-214 0.656 +/-0.0958 0.0353 +/-0.0958 0.0705 pCi/g Manganese-54 U 0.00639 +/-0.0202 0.0182 +/-0.0202 0.0363 pCi/g Niobium-94 U 0.017 +/-0.024 0.0173 +/-0.024 0.0346 pCi/g Potassium-40 10.7 +/-1.03 0.149 +/-1.03 0.298 pCi/g Radium-226 0.549 +/-0.101 0.0374 +/-0.101 0.0748 pCi/g Silver-108m U -0.0123 +/-0.0189 0.0161 +/-0.0189 0.0321 pCi/g Thallium-208 0.231 +/-0.0502 0.0172 +/-0.0502 0.0344 pCi/g The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 43 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-006F Project: YANK01204 Sample ID: 188898006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted. aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 44 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Ana....

Certificateo Company : Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-007F Proiect: YANK01204 Sample ID: 188898007 Client ID: YANKOOI Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 1.71%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 +/-0.294 0.207 +/-0.295 0.580 pCi/g DXH2 07/06/07 0815 648282 1 Curium-242 U --0.0152 +/-0.128 0.0569 +/-0.128 0.286 pCi/g Curium-243/244 U -0.219 +/-0.175 0.241 +/-0.177 0.648 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U --0.0275 +/-0.119 0.0727 +/-0.119 0.301 pCi/g DXH2 07/05/07 0809 648283 3 Plutonium-239/240 U 0.0435 +1-0.115 0.0514 +/-0.116 0.258 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -11.2 +/-15.6 13.4 +/-15.6 27.4 pCi/g DXH2 07/06/07 0825 648286 4 Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.733 +/-0.166 0.0599 .+/-0.166 0.120 pCi/g MJHI 07/03/07 1405 648306 5 Americium-241 U -0.0102 +/-0.0999 0.0799 +/-0.0999 0.160 pCi/g Bismuth-212 0.392 +/-0.283. 0.130 +/-0.283 0.261 pCi/g Bismuth-214 0.559 +/-0.0944 0.0308 +/-0.0944 0.0615 pCi/g Cesium-134 U 0.023 +/-0.0218 0.020 +/-0.0218 0.0399 pCi/g Cesium-137 U 0.0111 +/-0.021 0.0173 +/-0.021 0.0346 pCi/g Cobalt-60 U 0.0141 +/-0.0239 0.0212 +/-0.0239 0.0425 pCi/g Europium-152 U 0.0119 +/-0.0594 0.0453 +/-0.0594 0.0905 pCi/g Europium-154 U -0.0886 +/-0.0724 0.053 +/-0.0724 0.106 pCi/g Europium-155 U 0.0502 +/-0.0586 0.0528 +/-0.0586 0.106 pCi/g Lead-212 0.685 +/-0.0772 0.0256 +/-0.0772 0.0512 pCi/g Lead-214 0.618 +/-0.0854 0.0329 +/-0.0854 0.0658 pCi/g Manganese-54 U -0.00285 +/-0.0196 0.0163 +/-0.0196 0.0325 pCi/g Niobium-94 U 0.00445 +/-0.0189 0.0164 +/-0.0189 0.0328 pCi/g Potassium-40 11.9 +/-1.29 0.163 +/-1.29 0.326 pCi/g Radium-226 0.559 +/-0.0944 0.0308 +/-0.0944 0.0615 pCi/g Silver-108m U 0.000619 +/-0.0188 0.0146 +/-0.0188 0.0292 pCi/g Thallium-208 0.232 +/-0.0446 0.0155 +/-0.0446 0.031 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00685 +/-0.0121 0.0108 +/-0.0121 0.0242 pCi/g NXL3 07/05/07 1144 648289 6 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U -0.534 +/-1.23 1.06 +/-1.23 2.21 pCi/g SLN1 07/03/07 1331 647976 7 Page 45 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-007F Project: YANK01204 Sample ID: 188898007 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AllFSS Carbon-14 U -0.0484 +/-0.114 0.0965 +/-0.114 0.197 pCilg AXD2 07/03/07 1600 647980 8 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -8.94 +/-23.6 16.8 +/-23.6 35.4 pCilg MXP1 07/05/07 1929 648290 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.78 +/-7.22 5.83 +/-7.27 12.3 pCilg MXP1 07/09/07 0850 649056 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0314 +/-0.0758 0.0641 +/-0.0758 0.130 pCilg MXPI 07/10/07 0959 647974 13 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu- 11 -RC Modified 4 DOE EML HASL-300, Pu- 11 -RC Modified 5 EML HASL 300, 4.5.2.3 6 EPA 905.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-1, Modified 11 DOE RESL Ni-i, Modified 12 DOE RESL Ni- 1, Modified 13 DOE EML HASL-300, Tc-02-RC Modified 14 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Americium-243 Tracer Alphaspec Am241, Cm, Solid ALL 81 (15%-125%)

Plutonium-242 Tracer Alphaspec Pu, Solid-ALL FSS 86 (15%-125%)

Plutonium-242 Tracer Liquid Scint Pu241, Solid-ALL F5 98 (25%-125%)

Strontium Carrier GFPC, Sr9O, solid-ALL FSS 86 (25%-125%)

Iron-59 Tracer Liquid Scint Fe55, Solid-ALL FS 92 (15%-125%)

Nickel Carrier Liquid Scint Ni63, Solid-ALL FS 89 (25%-125%)

Technetium-99m Tracer Liquid Scint Tc99, Solid-ALL FS 83 (15%-125%)

Page 46 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-007F Project: YANKO1204 Sample ID: 188898007 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TICis a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 47 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-008F Project: YANK01204 Sample ID: 188898008 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 3.21%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.729 +/-0.170 0.0546 +/-0.170 0.109 pCi/g MJH 1 07/03/07 1405 648306 1 Americium-241 U -0.00083 +/-0.066 0.0542 +/-0.066 0.108 pCi/g Bismuth-212 UI 0.00 +/-0.234 0.168 +/-0.234 0.336 pCi/g Bismuth-214 0.543 +/-0.0901 0.0291 +/-0.0901 0.0581 pCi/g Cesium- 134 UI 0.00 +/-0.0442 0.0238 +/-0.0442 0.0475 pCi/g Cesium-137 0.0605 +/-0.0322 0.0162 +/-0.0322 0.0323 pCi/g Cobalt-60 U -0.00721 +/-0.0204 0.0164 +/-0.0204 0.0327 pCi/g Europium-152 U -0.0158 +/-0.0601 0.0457 +/-0.0601 0.0914 pCilg Europium-154 U -0.0245 +/-0.0671 0.0513 +/-0.0671 0.103 pCi/g Europium-155 U 0.0148 +/-0.0694 0.050 +/-0.0694 0.100 pCi/g Lead-212 0.663 +/-0.0735 0.026 +/-0.0735 0.052 pCi/g Lead-214 0.530 +/-0.0938 0.0314 +/-0.0938 0.0628 pCi/g Manganese-54 U 0.014 +/-0.0191 0.0176 +/-0.0191 0.0351 pCi/g Niobium-94 U -0.00409 +/-0.0188 0.0156 +/-0.0188 0.0313 pCi/g Potassium-40 10.2 +/-0.960 0.150 +/-0.960 0.299 pCi/g Radium-226 0.543 +/-0.0901 0.0291 +/-0.0901 0.0581 pCi/g Silver-108m U -0.0133 +/-0.0178 0.0148 +/-0.0178 0.0297 pCi/g Thallium-208 0.202 +/-0.0464 0.0166 +/-0.0464 0.0331 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 48 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-008F Proiect: YANK01204 Sample ID: 188898008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 49 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificateof Analvsis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-009F Project: YANK01204 Sample ID: 188898009 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 1.72%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.727 +/-0.225 0.0974 +/-0.225 0.195 pCi/g MJHI 07/03/07 1405 648306 1 Americium-241 U -0.0287 +/-0.0374 0.0324 +/-0.0374 0.0647 pCi/g Bismuth-212 U 0.328 +/-0.428 0.228 +/-0.428 0.455 pCi/g Bismuth-214 0.571 +/-0.125 0.0505 +/-0.125 0.101 pCi/g Cesium-134 U 0.0565 +/-0.0475 0.0331 +/-0.0475 0.0662 pCi/g Cesium- 137 UI 0.00 +/-0.0546 0.027 +/-0.0546 0.0539 pCi/g Cobalt-60 U 0.0317 +/-0.0303 0.0298 +/-0.0303 0.0596 pCi/g Europium-152 U -0.0128 +/-0.0765 0.0629 +/-0.0765 0.126 pCi/g Europium- 154 U 0.0036 +/-0.105 0.0883 +/-0.105 0.177 pCi/g Europium- 155 U 0.0864 +/-0.094 0.0507 +/-0.094 0.101 pCi/g Lead-212 0.578 +/-0.0791 0.0345 +/-0.0791 0.069 pCi/g Lead-214 0.515 +/-0.114 0.0455 +/-0.114 0.0909 pCi/g Manganese-54 U -0.00452 +/-0.0302 0.0253 +/-0.0302 0.0506 pCi/g Niobium-94 U -0.00593 +/-0.0301 0.0258 +/-0.0301 0.0515 pCi/g Potassium-40 9.31 +/-1.12 0.276 +/-1.12 0.551 pCi/g Radium-226 0.571 +/-0.125 0.0505 +/-0.125 0.101 pCi/g Silver-108m U -0.0118 +/-0.0265 0.0224 +/-0.0265 0.0447 pCi/g Thallium-208 0.191 +/-0.0578 0.0252 +/-0.0578 0.0504 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 50 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-009F Proiect: YANK01204 Sample ID: 188898009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 51 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis. Ana....

Certificateof Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-01 OF Proiect: YANK01204 Sample ID: 188898010 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 4.76%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.122 +/-0.211 0.090 +/-0.212 0.372 pCi/g DXH2 07/06/07 0815 648282 1 Curium-242 U --0.0351 +/-0.151 0.0929 +/-0.152 0.384 pCi/g Curium-243/244 U 0.0482 +/-0.342 0.270 +/-0.342 0.732 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.176 +/-0.181 0.236 +/-0.183 0.655 pCi/g DXH2 07/06/07 0815 648283 3 Plutonium-239/240 U 0.0353 +/-0.140 0.0861 +/-0.140 0.356 .pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -10.4 +/-16.9 14.4 +/-16.9 29.5 pCi/g DXH2 07/06/07 0902 648286 5 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.732 +/-0.147 0.0606 +/-0.147 0.121 pCi/g MJH1 07/03/07 1406 648306 6 Americium-241 U 0.0157 +/-0.0802 0.0627 +/-0.0802 0.125 pCi/g Bismuth-212 0.705 +/-0.267 0.101 +/-0.267 0.201 pCi/g Bismuth-214 0.622 +/-0.106 0.031 +/-0.106 0.0619 pCi/g Cesium-134 U 0.0262 +/-0.0308 0.0233 +/-0.0308 0.0466 pCi/g Cesium- 137 0.266 +/-0.0512 0.018 +/-0.0512 0.0359 pCi/g Cobalt-60 U 0.000289 +/-0.025 0.0202 +/-0.025 0.0404 pCi/g Europium-152 U -0.0311 +/-0.0835 0.0479 +/-0.0835 0.0957 pCi/g Europium-154 U 0.00883 +/-0.0614 0.0526 +/-0.0614 0.105 pCi/g Europium-155 U 0.091 +/-0.155 0.0523 +/-0.155 0.105 pCi/g Lead-212 0.787 +/-0.0842 0.0274 +/-0.0842 0.0548 pCi/g Lead-214 0.681 +/-0.101 0.034 +/-0.101 0.068 pCi/g Manganese-54 U -0.00529 +/-0.0204 0.0174 +/-0.0204 0.0347 pCi/g Niobium-94 U 0.0162 +/-0.0198 0.0157 +/-0.0198 0.0314 pCi/g Potassium-40 11.4 +/-1.07 0.156 +/-1.07 0.311 pCi/g Radium-226 0.622 +/-0.106 0.031 +/-0.106 0.0619 pCi/g Silver-108m U -0.00889 +/-0.0216 0.0162 +/-0.0216 0.0323 pCi/g Thallium-208 0.231 +/-0.0488 0.0172 +/-0.0488 0.0345 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00877 +/-0.0111 0.0103 +/-0.0111 0.0231 pCi/g NXL3 07/05/07 1144 648289 7 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U 0.401 +/-1.29 1.07 +/-1.30 2.24 pCi/g SLN1 07/03/07 1433 647976 8 Page 52 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-010F Proiect: YANK01204 Sample ID: 188898010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All,FSS Carbon-14 U - +/-0.111 0.0955 +/-0.111 0.195 pCi/g AXD2 07/03/07 1705 647980 9 Liquid Scint FeSS, Solid-ALL FSS Iron-55 U 10.6 +/-27.7 19.3 +/-27.8 40.9 pCi/g MXP1 07/05/07 1945 648290 10 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 2.47 +/-7.02 5.77 +/-7.03 12.2 pCi/g MXP1 07/09/07 0906 649056 11 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0331 +/-0.0982 0.0815 +/-0.0983 0.168 pCi/g MXP1 07/10/07 1202 647974 14 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-i I-RC Modified 4 DOE EML HASL-300, Pu- 11-RC Modified 5 DOE EML HASL-300, Pu-I I-RC Modified 6 EML HASL 300, 4.5.2.3 7 EPA 905.0 Modified 8 EPA 906.0 Modified 9 EPA EERF C-01 Modified 10 DOE RESL Fe-1, Modified 11 DOE RESL Ni-i, Modified 12 DOE RESL Ni-I, Modified 13 DOE RESL Ni-l, Modified 14 DOE EML HASL-300, Tc-02-RC Modified 15 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Tracer Alphaspec Am241, Cm, Solid ALL 79 (15%-125%)

Plutonium-242 Tracer Alphaspec Pu, Solid-ALL FSS 93 (15%-125%)

Plutonium-242 Tracer Liquid Scint Pu241, Solid-ALL FS 89 (25%-125%)

Strontium Carrier GFPC, Sr9O, solid-ALL FSS 86 (25%-125%)

Iron-59 Tracer Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)

Nickel Carrier Liquid Scint Ni63, Solid-ALL FS 90 (25%-125%)

Page 53 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-OIOF Project: YANK01204 SampleID: 188898010 ClientID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst.Date Time Batch Mtd Technetium-99m Tracer Liquid Scint Tc99, Solid-ALL FS 81 (15%- 125%)

Notes:

The Qualifiers in this report are defined as follows

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 54 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-01IF Project: YANK01204 Sample ID: 188898011 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 1.69%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.643 +/-1-0.192 0.0704 +/-0.192 0.141 pCi/g MJHI 07/03/07 1406 648306 1 Americium-241 U 0.0465 +/-0.0388 0.0343 +/-0.0388 0.0685 pCi/g Bismuth-212 U 0.167 +/-0.216 0.195 +/-0.216 0.391 pCi/g Bismuth-214 0.495 +1-0.10f, 0.0391 +/-0.101 0.0781 pCi/g Cesium-134 U 0.0283 +/-0.0279 0.0262 +/-0.0279 0.0523 pCi/g Cesium-137 0.111 +1-0.0473 0.0193 +/-0.0473 0.0386 pCi/g Cobalt-60 U 0.0395 +/-0.0326 0.0277 +/-0.0326 0.0553 pCi/g Europium-152 U -0.0208 +/-0.0668 0.051 +/-0.0668 0.102 pCi/g Europiumm-154 U 0.0261 +/-0.087 0.076 +/-0.087 0.152 pCi/g Europium-ISS U 0.0471 +/-0.0621 0.0494 +/-0.0621 0.0988 pCi/g Lead-212 0.699 +/-0.0941 0.0291 +/-0.0941 0.0582 pCi/g Lead-214 0.671 +/-0.0971 0.0376 +/-0.0971 0.0751 pCi/g Manganese-54 U 0.02 16 +/-0.0268 0.0224 +/-0.0268 0.0448 pCi/g Niobium-94 U -0.0112 +/-0.022 1 0.0179 +/-0.0221 0.0357 pCi/g

+/-1.17 Potassium-40 10.3 +/-1.17 0.137 0.273 pCi/g Radium-226 0.495 +/-0.101 0.0391 +/-0.101 0.0781 pCi/g Silver-108m U 0.0179 +/-0.0191 0.0182 +/-0.0191 0.0363 pCi/g Thallium-208 0.211 +/-0.0473 0.0173 +/-0.0473 0.0345 pCi/g The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

Page 55 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-01IF Proiect: YANK01204 Sample ID: 188898011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 56 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-012F Project: YANK01204 Sample ID: 188898012 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 2.52%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.677 +/-0.169 0.0538 +/-0.169 0.108 pCi/g MJH1 07/03/07 1407 648306 1 Americium-241 U 0.0399 +/-0.0671 0.0573 +/-0.0671 0.115 pCi/g Bismuth-212 0.457 +/-0.217 0.128 +/-0.217 0.255 pCi/g Bismuth-214 0.433 +/-0.0808 0.0301 +/-0.0808 0.0601 pCi/g Cesium- 134 UI 0.00 +/-0.0245 0.0199 +/-0.0245 0.0397 pCi/g Cesium- 137 UI 0.00 +/-0.0311 0.0149 +/-0.0311 0.0298 pCi/g Cobalt-60 U 0.000659 +/-0.0234 0.0171 +/-0.0234 0.0342 pCi/g Europium-152 U 0.00972 +/-0.0569 0.0426 +/-0.0569 0.0852 pCi/g Europium- 154 U -0.0294 +/-0.0674 0.0453 +/-0.0674 0.0904 pCi/g Europium- 155 U 0.0667 +/-0.0511 0.0488 +/-0.0511 0.0976 pCi/g Lead-212 0.638 +/-0.0683 0.023 +/-0.0683 0.0459 pCi/g Lead-214 0.511 +/-0.0873 0.0303 +/-0.0873 0.0606 pCi/g Manganese-54 U -0.00451 +/-0.0179 0.0154 +/-0.0179 0.0307 pCi/g Niobium-94 U 0.00523 +/-0.0172 0.0149 +/-0.0172 0.0298 pCi/g Potassium-40 9.02 +/-0.892 0.137 +/-0.892 0.273 pCi/g Radium-226 0.433 +/-0.0808 0.0301 +/-0.0808 0.0601 pCi/g Silver- 108m U 0.00657 +/-0.0182 0.0144 +/-0.0182 0.0289 pCi/g Thallium-208 0.190 +/-0.044 0.016 +1-0.044 0.0321 pCi/g The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 57 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-012F Project: YANK01204 Sample ID: 188898012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 58 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-013F Proiect: YANK01204 Sample ID: 188898013 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 2.33%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.686 +/-0.169 0.0601 +/-0.169 0.120 pCi/g MJH1 07/03/07 1407 648306 1 Americium-241 U 0.119 +/-0.0903 0.0784 +/-0.0903 0.157 pCi/g Bismuth-212 UI 0.00 +/-0.249 0.176 +/-0.249 0.353 pCi/g Bismuth-214 0.521 +/-0.104 0.0329 +/-0.104 0.0657 pCi/g Cesium-134 U 0.0278 +/-0.0322 0.0225 +/-0.0322 0.0449 pCi/g Cesium-137 0.687 +/-0.0779 0.0213 +/-0.0779 0.0426 pCi/g Cobalt-60 U 0.0168 +/-0.0201 0.0173 +/-0.0201 0.0345 pCi/g Europium-152 U -0.0138 +/-0.0852 0.0518 +/-0.0852 0.104 pCi/g Europium-154 U 0.0343 +/-0.0587 0.0533 +/-0.0587 0.107 pCi/g Europium-155 U 0.0232 +/-0.0614 0.0565 +/-0.0614 0.113 pCi/g Lead-212 0.809 +/-0.0878 0.0283 +/-0.0878 0.0566 pCi/g Lead-214 0.656 +/-0.115 0.0369 +1-0.115 0.0737 pCi/g Manganese-54 U 0.0111 +/-0.0213 0.0187 +/-0.0213 0.0374 pCi/g Niobium-94 U -0.00564 +/-0.0185 0.0154 +/-0.0185 0.0308 pCi/g Potassium-40 9.41 +/-0.973 0.137 +/-0.973 0.273 pCi/g Radium-226 0.521 +/-0.104 0.0329 +/-0.104 0.0657 pCi/g Silver-108m U -0.00773 +/-0.0191 0.0165 +/-0.0191 0.0331 pCi/g Thallium-208 0.210 +/-0.0429 0.0186 +/-0.0429 0.0372 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 59 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-013F Project: YANK01204 Sample ID: 188898013 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 60 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-014F Proeect: YANK01204 Sample ID: 188898014 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 4.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammia,Solid-FSS GAM &ALL FSS 226 Ingrowth Waived Actinium-228 0.781 +/-0.207 0.0885 +/-0.207 0.177 pCi/g MJH1 07/03/07 1408 648306 1 Americium-241 U 0.0187 +/-0.0468 0.0377 +/-0.0468 0.0753 pCi/g Bismuth-212 U 0.491 +1-0.311 0.303 +/-0.311 0.605 pCi/g Bismuth-214 0.573 +/-0.141 0.0584 +/-0.141 0.117 pCi/g Cesium-134 U 0.0466 +1-0.0421 0.0401 +/-0.0421 0.0801 pCilg Cesium-137 0.0944 +/-0.0503 0.028 +/-0.0503 0.0559 pCilg Cobalt-60 U -0.00858 +/-0.0388 0.0311 +/-0.0388 0.0622 pCi/g Europium-i 52 U-0.000936 +/-0.0927 0.0662 +/-0.0927 0.132 pCi/g Europium-154 U 0.129 +/-0.113 0.110 +/-0.113 0.219 pCi/g Europium-155 U 0.0816 +/-0.0701 0.0579 +/-0.0701 0.116 pCi/g Lead-2 12 0.707 +/-0.0934 0.0354 +/-0.0934 0.0707 pCi/g Lead-2 14 0.491 +/-0.126 0.0508 +/-0.126 0.102 pCi/g Manganese-54 U -0.0101 +/-0.0318 0.0264 +/-0.0318 0.0528 pCi/g Niobium-94 U 0.0064 +1-0.0308 0.0274 +/-0.0308 0.0548 pCilg Potassium-40 10.1 +1-1.34 0.296 +/-1.34 0.591 pCi/g Radium-226 0.573 +/-0.141 0.0584 +/-0.141 0.117 pCi/g Silver-108m U -0.00166 +/-0.0301 0.0257 +/-0.0301 0.0513 pCi/g Thallium-208 0.190 +/-0.0641 0.0279 +/-0.0641 0.0558 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 61 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-014F Project: YANK01204 Sample ID: 188898014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma'Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound

^ RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 62 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-015F Proiect: YANK01204 Sample ID: 188898015 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 2.51%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.644 +1-0.127 0.0453 +/-0.127 0.0905 pCi/g MJH1 07/03/07 1408 648306 1 Amnericium-241 U 0.0356 +/-0.0639 0.053 +/-0.0639 0.106 pCi/g Bismuth-212 0.308 +/-0.215 0.0998 +/-0.215 0.200 pCi/g Bismuth-214 0.526 +/-0.0802 0.0205 +/-0.0802 0.0409 pCi/g Cesium-I 34 U 0.0255 +/-0.0205 0.0136 +/-0.0205 0.0273 pCi/g Cesium-137 0.068 +/-0.0314 0.0125 +/-0.0314 0.025 pCi/g Cobalt-60 U 0.00867 +/-0.0181 0.0141 +/-0.0181 0.0281 pCi/g Europium- 152 U 0.00881 +/-0.0532 0.0362 +/-0.0532 0.0724 pCi/g Europium-154 U -0.0339 +/-0.0438 0.0352 +/-0.0438 0.0704 pCi/g Europium-ISS U 0.0656 +/-0.0587 0.0432 +/-0.0587 0.0863 pCi/g Lead-212 0.637 +/-0.0652 0.0213 +/-0.0652 0.0426 pCi/g Lead-214 0.479 +/-0.0708 0.026 +/-0.0708 0.0521 pCi/g Manganese-54 U 0.0198 +/-0.0174 0.013 +/-0.0174 0.0259 pCi/g Niobium-94 U -0.00331 +/-0.0147 0.0125 +/-0.0147 0.0249 pCi/g Potassium-40 10.4 +/-0.887 0.114 +/-0.887 0.228 pCi/g Radium-226 0.526 +/-0.0802 0.0205 +/-0.0802 0.0409 pCi/g Silver-108m U -0.0107 +/-0.0138 0.0115 +/-0.0138 0.0229 pCi/g Thallium-208 0.172 +/-0.0352 0.0135 +/-0.0352 0.0269 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 63 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-015F Project: YANK01204 Sample ID: 188898015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 64 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certifle2fr of Analysis C Pr t i fl*CA 1 f if-Am)

Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-015FS Project: YANK01204 Sample ID: 188898016 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 30-JUN-07 Collector: Client Moisture: 2.33%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.652 +/-0.167 0.0628 +/-0.167 0.126 pCi/g MJHI 07/03/07 1408 648306 1 Americium-241 U 0.0291 +/-0.0928 0.0773 +/-0.0928 .0.155 pCi/g Bismuth-212 UI 0.00 +/-0.221 0.173 +/-0.221 0.347 pCi/g Bismuth-214 0.455 +/-0.0881 0.0383 +/-0.0881 0.0766 pCi/g Cesium- 134 U 0.0293 +/-0.0356 0.0231 +/-0.0356 0.0463 pCi/g Cesium- 137 0.0708 +/-0.0385 0.0186 +/-0.0385 0.0371 pCi/g Cobalt-60 U 0.00865 +/-0.0227 0.018 +/-0.0227 0.0359 pCi/g Europium- 152 U -0.0404 +/-0.0498 0.0405 +/-0.0498 0.0809 pCi/g Europium- 154 U -0.00271 +/-0.0777 0.0657 +/-0.0777 0.131 pCi/g Europium- 155 U 0.0203 +/-0.0487 0.0463 +/-0.0487 0.0926 pCi/g Lead-212 0.583 +/-0.0678 0.0256 +/-0.0678 0.0512 pCi/g Lead-214 0.487 +/-0.0933 0.0324 +/-0.0933 0.0647 pCi/g Manganese-54 U 0.0146 +/-0.0392 0.0191 +/-0.0392 0.0381 pCi/g Niobium-94 U 0.00972 +/-0.0209 0.0188 +/-0.0209 0.0376 pCi/g Potassium-40 9.86 +/-1.08 0.146 +/-1.08 0.293 pCilg Radium-226 0.455 +/-0.0881 0.0383 +/-0.0881 0.0766 pCi/g Silver- 108m U 0.00776 +/-0.0186 0.0167 +/-0.0186 0.0333 pCi/g Thallium-208 0.172 +/-0.0429 0.0188 +/-0.0429 0.0376 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 65 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 10, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-015FS Proiect: YANK01204 Sample ID: 188898016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 66 of 76

.I QUALITY CONTROL DATA II Page 67 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 10, 2007 Client : Connecticut Yankee Atomic Power Page 1 of 9 Company Haddam Neck Plant 362 Injun Hollow Road Haddam Neck, Connecticut

Contact:

Mr. Rick Gault Workorder: 188898 Parmname NOM Samule Oual OC Units RPD % REC% Ranee AnIst Date Time Parmname Rad Alpha Spec Batch 648282 QC 1201369360 188898007 DUP Americium-241 U 0.110 U 0.0718 pCi/g 42 N/A DXH2 07/06/0708:15 Uncert: +/-0.294 +/-0.183 TPU: +/-0.295 +/-0.183 Curium-242 U -0.0152 U -0.12 pCi/g 155 N/A Uncert: +/-0.128 +/-0.148 TPU: +/-0.128 +/-0.148 Curium-243/244 U -0.219 U -0.245 pCi/g 11 N/A Uncert: +/-0.175 +/-0.177 TPU: +/-0.177 +/-0.180 QC1201369362 LCS Americium-241 24.7 25.9 pCi/g 105 (75%-125%)

Uncert: +/-2.30 TPU: +/-4.29 Curium-242 lU -0.039 pCi/g Uncert: +/-0.115 TPU: +/-0.115 Curium-243/244 29.3 29.7 pci/g 101 (75%-125%)

Uncert: +/-2.48 TPU: +/-4.83 QC1201369359 MB Americium-241 U -0.0936 pci/g 07/06/0708:15 Uncert: +/-0.089 TPU: +/-0.090 Curium-242 U -0.0598 pCilg Uncert: +/-0.135 TPU: +/-0.135 Curium-243/244 U -0.022 pCilg Uncert: +/-0.234 TPU: +/-0.234 QC1201369361 188898007 MS Americium-241 24.7 U 0.110 27.4 pci/g 110 (75%-125%) 07/06/0708:15 Uncert: +/-0.294 +/-2.45 TPU: +/-0.295 +/-4.57 Curium -242 U -0.0152 U -0.0419 pCilg Uncert: +/-0.128 +/-0.124 TPU: +/-0.128 +/-0.124 Curium-243/244 29.3 U -0.219 29.8 pCilg 102 (75%-125%)

Uncert: +/-0.175 +/-2.55 TPU: +/-0.177 +/-4.92 Batch 648283 QC1201369364 188898007 DUP Page 68 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch

  • 648283 Plutonium-238 U -0.0275 U -0.0149 pCi/g 59 N/A DXH2 07/05/0708:09 Uncert: +/-0.119 +/-0.125 TPU: +/-0.119 +/-0.125 Plutonium-239/240 U 0.0435 U 0.0323 pCilg 30 N/A Uncert: +/-0.115 +/-0.128 TPU: +/-0.116 +/-0.129 QC1201369366 LCS Plutonium-238 U 0.157 pCi/g (75%-125%)

Uncert: +/-0.195 TPU: +/-0.196 Plutonium-239/240 24.6 25.1 pCi/g 102 (75%-125%)

Uncert: +/-2.35 TPU: +/-3.92 QC1201369363 MB Plutonium-238 U -0.054 pCilg 07/06/0708:15 Uncert: +/-0.197 TPU: +/-0.197 Plutonium-239/240 U 0.0786 pCilg Uncert: +/-0.177 TPU: +/-0.178 QC1201369365 188898007 MS Plutonium-238 U -0.0275 U -0.0647 pCilg (75%-125%)

Uncert: +/-0.119 +/-0.188 TPU: +/-0.119 +/-0.188 Plutonium-239/240 24.6 U 0.0435 23.8 pCilg 97 (75%-125%)

Uncert: +/-0.115 +/-2.30 TPU: +/-0.116 +/-3.77 Batch 648286 QC1201369373 188898007 DUP Plutonium-241 U -11.2 U -3.22 pCi/g 0 N/A DXH2 07/06/0710:15 Uncert: +/-15.6 +/-14.8 TPU: +/-15.6 +/-14.8 QC1201369375 LCS Plutonium-241 34400 34700 pCi/g 101 (75%-125%) 07/06/0711:29 Uncert: +/-176 TPU: +/-6690 QC1201369372 MB Plutonium-241 U -1.64 pCilg 07/06/0709:39 Uncert: +/-16.3 TPU: +/-16.3 QC1201369374 188898007 MS Plutonium-241 34400 U -11.2 34400 PCi/g 100 (75%-125%) 07/06/0710:52 Uncert: +/-15.6 +/-175 TPU: +/-15.6 +/-6690 Rad Gamma Spec Batch 648306 QC1201369416 188898001 DUP Actinium-228 0.790 0.597 pCi/g 28 (0% - 100%) MJH1 07/03/0716:10 Page 69 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 648306 Uncert: +/-0.181 +/-0.250 TPU: +/-0.181 +/-0.250 Americium-241 U 0.0695 U 0.023 pCi/g 101 N/A Uncert: +/-0.107 +/-0.0418 TPU: +/-0.107 +/-0.0418 Bismuth-212 Ul 0.00 Ul 0.00 pCi/g 28 N/A Uncert: +/-0.252 +/-0.392 TPU: +/-0.252 +/-0.392 Bismuth-214 0.605 0.699 pC/g 14 (0% - 20%)

Uncert: +/-0.115 +/-0.144 TPU: +/-0.115 +/-0.144 Cesium- 134 U 0.028 U 0.0469 pCi/g 51 N/A Uncert: +/-0.0325 +/-0.0395 TPU: +/-0.0325 +/-0.0395 Cesium- 137 0.053 U 0.0106 pCi/g 133* (0%- 100%)

Uncert: +/-0.0415 +/-0.0379 TPU: +/-0.0415 +/-0.0379 Cobalt-60 U 0.0365 U -0.0191 pCi/g 637 N/A Uncert: +/-0.0236 +/-0.0318 TPU: +/-0.0236 +/-0.0318 Europium- 152 U -0.0153 U -0.038 pCi/g 85 N/A Uncert: +/-0.0903 +/-0.0789 TPU: +/-0.0903 +/-0.0789 Europium- 154 U -0.0106 U 0.126 pCi/g 236 N/A Uncert: +/-0.0675 +/-0.177 TPU: +/-0.0675 +/-0.177 Europium- 155 U 0.0515 U 0.0681 pCi/g 28 N/A Uncert: +/-0.0609 +/-0.0623 TPU: +/-0.0609 +/-0.0623 Lead-212 0.703 0.669 pCi/g 5 (0% - 20%)

Uncert: +/-0.083 +/-0.0855 TPU: +/-0.083 +/-0.0855 Lead-214 0.607 0.581 pCi/g 4 (0%- 20%)

Uncert: +/-0.0952 +/-0.123 TPU: +/-0.0952 +/-0.123 Manganese-54 U 0.00726 U -0.00933 pCi/g 1600 N/A Uncert: +/-0.0251 +/-0.0328 TPU: +/-0.0251 +/-0.0328 Niobium-94 U -0.00582 U 0.00105 pCi/g 288 N/A Uncert: +/-0.019 +/-0.0316 TPU: +/-0.019 +/-0.0316 Potassium-40 10.4 10.7 pCi/g 3 (0% - 20%)

Uncer:. +/-1.02 +/-1.16 TPU: +/-1.02 +/-1.16 Radium-226 0.605 0.699 pCi/g 14 (0% - 20%)

Uncer: +/-0.115 +/-0.144 TPU: +/-0.115 +/-0.144 U 0.00161 pCi/g 356 N/A Silver- 108m U -0.000452 Page 70 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 648306 Uncert: +/-0.0191 +/-0.0269 TPU: +/-0.0191 +/-0.0269 Thallium-208 0.228 0.220 pCi/g 4 (0% - 100%)

Uncert: +/-0.0478 +/-0.0607 TPU: +/-0.0478 +/-0.0607 QC1201369417 LCS Actinium-228 0.728 pCi/g 07/03/0716:11 Uncert: +/-0.734 TPU: +/-0.734 Americium-241 16.0 13.6 pCi/g 85 (75%-125%)

Uncert: +/-1.03 TPU: +/-1.03 Bismuth-212 U 0.743 pCi/g Uncert: +/-0.731 TPU: +/-0.731 Bismuth-214 0.650 pCi/g Uncert: +/-0.285 TPU: +/-0.285 Cesium- 134 U 0.0651 pCi/g Uncert: +/-0.101 TPU: +/-0.101 Cesium- 137 6.16 5.97 pCi/g 97 (75%-125%)

Uncert: +/-0.587 TPU: +/-0.587 Cobalt-60 9.01 9.15 pCi/g 102 (75%-125%)

Uncert: +/-0.660 TPU: +/-0.660 Europium- 152 U 0.050 pCi/g Uncert: +/-0.237 TPU: +/-0.237 Europium- 154 U 0.035 pCi/g Uncert: +/-0.226 TPU: +/-0.226 Europium- 155 U 0.0619 pCi/g Uncert: +/-0.184 TPU: +/-0.184 Lead-212 0.961 pCi/g Uncert: +/-0.162 TPU: +/-0.162 Lead-214 0.710 pCi/g Uncert: +/-0.242 TPU: +/-0.242 Manganese-54 U 0.0353 pCi/g Uncert: +/-0.090 TPU: +/-0.090 Niobium-94 U -0.0707 pCi/g Uncert: +/-0.0831 TPU: +/-0.0831 Page 71 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 648306 Potassium-40 1.64 pCilg Uncert:

+/-1.13 TPU:

+/-1.13 Radium-226 0.650 pCi/g (75%-125%)

Uncert: +/-0.285 TPU: +/-0.285 Silver-108m U -0.0417 pCi/g Uncert: +/-0.0749 TPU: +/-0.0749 Thallium-208 0.284 pCi/g Uncert: +/-0.134 TPU: +/-0.134 QC1201369415 MB Actinium-228 U 0.0777 pCi/g 07/03/0716:10 Uncert: +/-0.106 TPU: +/-0.106 Americium-241 U -0.0338 pCilg Uncert: +/-0.0219 TPU: +/-0.0219 Bismuth-212 U 0.0494 pCi/g Uncert: +/-0.157 TPU: +/-0.157 Bismuth-214 U 0.0357 pCi/g Uncert: +/-0.0478 TPU: +/-0.0478 Cesium- 134 U 0.0176 pCi/g Uncert: +/-0.0198 TPU: +/-0.0198 Cesium- 137 U -0.00771 pCilg Uncert: +/-0.0188 TPU: +/-0.0188 Cobalt-60 U 0.018 pCi/g Uncert: +/-0.0205 TPU: +/-0.0205 Europium- 152 U 0.042 pCi/g Uncert: +/-0.0531 TPU: +/-0.0531 Europium- 154 U -0.0422 PCi/g Uncert: +/-0.0551 TPU: +1-0.0551 Europium- 155 U -0.00751 pCi/g Uncert: +/-0.0409 TPU: +/-0.0409 Lead-212 U 0.0239 pCi/g Uncert: +/-0.0399 TPU: +/-0.0399 Lead-214 U 0.0168 PCi/g Uncert: +/-0.0625 Page 72 of 76

. GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 6 of 9 Parmname NOM Samule Oual OC Units RPD% REC% Range Anlst Date Time NOM Samnle Oual OC Units RPD% REC% RanLye AnIst Rad Gamma Spec Batch 648306 TPU: +/-0.0625 Manganese-54 U -0.00455 pCi/g Uncert: +/-0.0178 TPU: +/-0.0178 Niobium-94 U -0.00628 pCi/g Uncert: +/-0.0208 TPU: +/-0.0208 Potassium-40 UI 0.00 pCi/g Uncert: +/-0.231 TPU: +/-0.231 Radium-226 U 0.0357 pCi/g Uncert: +/-0.0478 TPU: +/-0.0478 Silver-108m .pCilg U 0.00689 Uncert: +/-0.0191 TPU: +/-0.0191 Thallium-208 U 0.000286 pCilg Uncert: +/-0.0209 TPU: +/-0.0209 Rad Gas Flow Batch 648289 QC1201369377 188898010 DUP Strontium-90 U -0.00877 U 0.013 pCi/g 0 N/A NXL3 07/06/0710:37 Uncert: +/-0.0111 +/-0.0246 TPU: +/-0.0111 +/-0.0248 QC1201369379 LCS Strontium-90 1.64 1.39 pCi/g 85 (75%-125%) 07/05/0711:45 Uncert: +/-0.0934 TPU: +/-0.291 QC1201369376 MB Strontium-90 U 0.00725 pCi/g 07/06/0710:37 Uncert: +/-0.0154 TPU: +/-0.0155 QC1201369378 188898010 MS Strontium-90 1.64 U -0.00877 1.53 pci/g 93 (75%-125%) 07/05/0711:45 Uncert: +/-0.0111 +/-0.105 TPU: +/-0.0111 +/-0.320 Rad Liquid Scintillation Batch 647974 QC1201368674 188898007 DUP Technetium-99 U -0.0314 U 0.163 pCi/g 0 N/AMXP1 07/10/0712:59 Uncert: +/-0.0758 +/-0.142 TPU: +/-0.0758 +/-0.144 QC1201368676 LCS Technetium-99 14.7 13.0 pCi/g 89 (75%-125%) 07/03/0723:28 Uncert: +/-0.427 TPU: +1-1.56 QC1201368673 MB Page 73 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 647974 Technetium-99 U 0.235 pCi/g Uncert: +/-0.171 TPU: +/-0.173 QC1201368675 188898007 MS Technetium-99 14.8 U -0.0314 14.7 99 (75%-125%) 07/03/0723:01 Uncert: +/-0.0758 +/-0.473 TPU: +/-0.0758 +/-1.76 Batch 647976 QC1201368683 188898010 DUP Tritium U 0.401 U 0.407 pCi/g 0 N/A SLN1 07/03/0716:38 Uncert: +/-1.29 +/-1.31 TPU: +/-1.30 +/-1.32 QC1201368685 LCS Tritium 11.2 13.9 pCi/g 124 (75%-125%) 07/03/0718:43 Uncert: +/-1.81 TPU: +/-3.64 QC1201368682 MB Tritium U -0.0975 pCi/g 07/03/0715:36 Uncert: +/-1.23 TPU: +/-1.23 QC1201368684 188898010 MS Tritium 11.6 U 0.401 12.1 pCi/g 104 (75%-125%) 07/03/0717:40 Uncert: +/-1.29 +/-1.84 TPU: +/-1.30 +/-3.31 Batch 647980 QC1201368694 188898007 DUP Carbon- 14 U -0.0484 U -0.121 pCi/g 0 N/A AXD2 07/03/0719:13 Uncert: +/-0.114 +/-0.115 TPU: +/-0.114 +/-0.115 QC1201368696 LCS Carbon- 14 7.05 6.59 pCilg 94 (75%-125%) 07/03/0721:21 Uncert: +/-0.208 TPU: +/-0.523 QC1201368693 MB Carbon- 14 U -0.109 pCi/g 07/03/0718:09 Uncert: +/-0.112 TPU: +/-0.112 QC1201368695 188898007 MS Carbon- 14 7.05 U -0.0484 6.26 pCi/g 89 (75%-125%) 07/03/0720:17 Uncert: +/-0.114 +/-0.204 TPU: +/-0.114 +/-0.499 Batch 648290 QC1201369381 188898010 DUP Iron-55 U 10.6 U 3.45 pCi/g 0 N/AMXP1 07/05/0720:18 Uncert: +/-27.7 +/-24.3 TPU: +/-27.8 +/-24.3 QC1201369383 LCS Iron-55 543 538 pCi/g 99 (75%-125%) 07/05/0720:51 Page 74 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 648290 Uncert: +/-44.7 TPU: +/-92.7 QC1201369380 MB Iron-55 U -2.5 pCi/g 07/05/0720:01 Uncert: +/-23.6 TPU: +/-23.6 QC1201369382 188898010 MS Iron-55 573 U 10.6 520 pCi/g 91 (75%-125%) 07/05/0720:34 Uncert: +/-27.7 +/-46.6 TPU: +/-27.8 +/-91.1 Batch 649056 QC1201370980 188898010 DUP Nickel-63 U 2.47 U -1.17 pCi/g 0 N/AMXP1 07/09/0709:38 Uncert: +/-7.02 +/-7.57 TPU: +/-7.03 +/-7.57 QC1201370982 LCS Nickel-63 481 372 pCi/g 77 (75%-125%) 07/09/0710:10 Uncert: +/-17.3 TPU: +/-71.1 QC1201370979 MB Nickel-63 U -0.897 pCi/g 07/09/0709:22 Uncert: +/-7.34

  • TPU: +/-7.34 QC1201370981 188898010 MS Nickel-63 484 U 2.47 415 pCi/g 86 (75%-125%) 07/09/0709:54 Uncert: +/-7.02 +/-19.5 TPU: +/-7.03 +/-79.4 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ut Gamma Spectroscopy--Uncertain identification Page 75 of 76

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188898 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 76 of 76

General Narrative Page 1 of 37

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 188968 SDG: MSR#07-0198 July 06, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on July 03, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 188968001 9520-0006-0241 188968002 9520-0006-0251 188968003 9520-0006-0261 188968004 9520-0006-0271 188968005 9520-0006-028I 188968006 9520-0006-0291 Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Eight soils were analyzed for FSSGAM.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

GEL Laboratories Pfige 2 PM9yP0712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.556.8171 F843.766.1178 www, gol.com

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the datacontained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl MJones Project Manager GEL Laboratories PKge 3 P OFIB0712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.555.8171 F843.7651178 www.golhCOm

List of current GEL Certifications as of 06 July 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG- 15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas NELAP T 104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 Page 4 of 37

Chain of Custody and Supporting Documentation Page 5 of 37

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20-005 Connecticut Yankee Atomic Power Company No. 2007-00158 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Clyde Newson 860-267- 3157 Analytical Lab (Name, City, State)

General Engineering Laboratories, 2040 Savage Road. Charleston SC. 29407 , <

843 556 8171. Attn. Cheryl Jones V Priority: [] 30 D. E] 14 D.JE 7'D. Z 3 D.

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample fD Code Code Code 9520-0006-0241 .. 6/29/07 1030 TS G BP X 9520-0006-0251 6/29/07 1158 TS G BP X 9520-0006-0261. 6/29/07 1210 TS G BP X 9520-0006-0271 . 7/2/07 0840 TS G BP X 9520-0006-0281 7/2/07 1030 TS G BP X 9520-0006-0291 ,.7/2/07.. 1040 TS G BP X NOTES: PO #: 002332 MSR #: 07- 0198 SSWP FSSP 9520-0006 E LTP QA ] Radwaste QA D Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.

El UPS C A_ _ _ __ Citndv Sealed9

1) Relinqp( B7 aate/Time 2) Retived By P-Date/Time El Hand Custody Seal ff7:/47 ) o 7/3/p704 j3 EL Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time "_YO NO Bill of Lading #
5) Relinquished By Date/Time 6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received: / 03 SDCi#: /t4.A S 9-- -- 0 7"-0 q K" Work Ord-r Number: 9 q_ __ _ ___ _ _

Shipping Container ID: 7' 1 , ý"a/ 3 Chain of Custody # , 607 -00t "

1. Custody Seals on shipping container intact? 'Yes KNo [I]
2. Custody Seals dated and signed? Yes K o[]
3. Chain-of-Custody record present? Yes ]'No
4. Cooler temperature_ __ _ _ _ __.---"
5. Vermiculite/packing materials is: Wet Dry
6. Number of samples in shilping container: '__

7., Sample holding times exceeded? Yes [] No

10. Were any anomalies identified in sample receipt?. Yes [1 No1
11. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: .Date:__. ;713OT7 Telephoned to: On_ By_

Page 45 of 56 I

Laboratories LLC SAMPLE RECEIPT & REVIEWTFORM Client: * 'SDG/ARCOC/Work Order: I (-v SS" Received By: Date Received:

Su dHazard Information *If Counts > x2 area background on samples not marked "radioactive",

SuspectedH co ct the Radiation Safety Group of further investigation.

COC/Samuples marked as radioactive? M dum Counts. Observed*:

Classified Radioactive I1 by RSO?

COC/Sanples marked containing PCBs?

Shipped as a DOT Hazardous? azard Class Shipped: UN#:

Samples identified as Foreign Soil?

Sample Receipt*Criteria *0 tComments/Qualifiers (Required for Non-Conforming Items)

Circle Applicable:

Shipping containers received intact and seals broke.n damaged container leaking container other (describe)

Preservation Method:

Samples requiring cold preservation ice bags blue ice dry ice none other (describe).

2within(4+1-2 C)?.2,2_

Chain of custody documents included with shipment?

Circle Applicable:

4 Sample containers intactand sealed? seals broken damaged container leaking container other (describe)

Sample ID's, containers affected and observed pH:

Samples requiruig-chemical preservation at proper pH? If.Preservation added, Lot#:

6 VOA vials free of headspace (defined Sample ID's and containers affected:

as < 6mm bubble)?,

7 Are Encore7containers resnt?(if '

present?

Ar Enoreconainrs

' i*::*/ yes, ':

immediately deliver to Volatiles laboratory),

Id's and teats affected:

8 Samples received within holding time?

9Sample. ID' son COC match ID's on Sample IM's and containers affected:

bottles?

10 Date & time on COC match date & Sample ID's affected:

time on bottles?

Number of containers received match Sample ID's affected:

number indicated on COC?

12 COC form Is properly signed in relinquished/received sections?

Comments:. .6., 7[b . *.

,+ ...

  • r' PM (or PMA) review: Initials Date

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major

~Chain of Custody Form 0 150 Connecticut Yankee Atomic Power Company C No. 2007.,0

('D 362 Injun Hollow Road, East Ilampton, CT 06424 o* 860-267-2556

" Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

ClydeNewson 860-267- 3157 Analylical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Prioriny: E] 30 D. [] 14 D.E] 7 D. M 3 D. C Sample Size- '.. ...

Sample Designation Date Time dpeNIC-jia &!!,;p;- Comment:Pr*scrvation I ab Sample ID Code Code CIt-_

9520-0006-0241 6/29/07 1030 TS G BP X 9520-0006-0251 6/29/07 1158 TS G BP X 9520-0006-0261 6,/29/07 1210 TS G BP X 9520-0006-0271 7/2/07 0840 TS G BP X 9520-0006-0281 7/2/07 1030 TS G BP X 9520-0006-0291 7/2,/07 1040 TS G BP X NOTES: PO #: 002332 MSR 4: 07- 0198 SSWP FSSP 9520-0006 Z LTP QA D Radwaste QA [1 Non QA Samples Shipped Via: Internal Container

[A Fed Ex Temp.: __ Deg.

El UPS C

1) Relinq ate/Time 2) Reived BY' ateiTime D Hand Custody Seal aq-=7
  • 3,)/- Pl li 0 Other Intact?
3) Relinquished Bv Date.'Time 4) Received By Date"/Time y-Y N Bill of Lading #
5) Relinquished By Date/Time 6) Received By Date/rime

~taern~n  ; Work foil A.na:.ytical Lab Eservices __---.~ CY-ISC-SOW-O01 Ftpu~rc 1. Samiple C'.heck-*in LP At 9- c-07-bl92'

",1CJ(:,taincr I.E q3

~L3 t~~ Ceiain ol Custo.dv 4

)..'stody% ;,:ueis shipp ing contauicr intaci? Yes Ko ['

fcslody .Seals ue-,,ed and ý;igne-3? Yes "vio []

A!i1,-of-Custo!Jv yccord Dresent! Yes "'No []

cr4i' temnperalure bermiculite/packing mnaterials is: Wet [] Dry?(

FIsatin1ples; ii i sh ipping container:

oube ____________

,aniple holdinLn. Time! exc;eeded' Yes [I No K *.,mtles have:

tape hazard labels ct

.eals __*~'appropriate sample Labels 9, Seaumples are:

_.X r, good condition leaking

-broken have air bubbles 1A.. W:.re any anomalies identified in sample receipt? Yes [ 1 No N 1.[. Description of anomalies (include sample numbcrs):

ami)'sod nLbratOr: CA - Date:

T iepr*c~re1do: __________On .By_

Page 45 of 56 Page 10 of 37

Laboratories LLC SAMPLE RECEIPT & REVIEW FORM client: V J (Q SDGIARCOCIWork Order: g,&I u !F Received By: Date Received: C S *If Counts-> x2 area background on samples not marked *radioactive",

Suspected Hazard. Information , copct the Radiation GSfe of hulbr investi n.

COC/Samples marked as radioactive? L_ m , Counts Observed*: . 0 C_, , ,

Clas sifie d R adio active 11 by RSO? ........-

COC/Samples marked containing PCBs? 1t .......

Shipped as a DOT Hazardous? t ?azarda Class Shipped: UN#:

Samples identified as Foreign Soil? ____

Sample Receipt Criteria " Comments/Qualifiers (Required for Non-Conforming Items)

Circle App*liable:

1 Shipping containers received intact and seals broken damaged container leaking container other (describe) sealed? . /

Pre.er.* adon Ma*d:

2 Samples requiring cold preservation ice bags blue ice dry ice none other (describe) within. (4 +/- 2 C)*? i_ - '

Chain of.custody documents included 3 with shipmen~t?

Cirole Appikcabltr 4 Sample containers intact and smcald? msboc aae otie kn otie t~r(ecie 5samri, es requiring chemica . /s;.. "'&*T=i= *.-"

~Sample Sampes rquirng ID's, rontainera affected and observed pH:

preservation at proper pH? ItPreservation added, Lot:

VOA vials free of headspace (defined Sample ID's and containers affected:

as < 6amm bubble)?,

(if "M,immediately d-liver to Volatlics laboraloy) 7 Are Encore containers present?.

Id's and teostaffectd:

8 Samples received within holding time?

Sample, ID' on COC match ID's on Sample ID. and containr affected:

bottles?

Date & time on COC match date & Sanqdc ID's affected:

l0time onbottles? L Number of containers rcived mat Sample VD' affected; number indicated on. COC?

12COC form i3 properly signed in relinquished/received sections Comments: to .

-I Date +

Page 1 0f N j' PMA) review: Initials

Data Review Qualifier Definitions Page 12 of 37

Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound
  • Result is less than value reported

> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories Page 1Igq&prx712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.556.8171 F843.765.1178 www.geh~corn

RADIOLOGICAL ANALYSIS Page 14 of 37

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 188968 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 648541 Prep Batch Number: 648478 Sample ID Client ID 188968001 9520-0006-0241 188968002 9520-0006-0251 188968003 9520-0006-0261 188968004 9520-0006-0271 188968005 9520-0006-0281 188968006 9520-0006-0291 1201369953 Method Blank (MB) 1201369954 188968001(9520-0006-0241) Sample Duplicate (DUP) 1201369955 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page. 15 of 37

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 188968001 (9520-0006-0241).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The duplicate and sample 1201369954 (9520-0006-0241) and 188968001 (9520-0006-0241) did not meet the relative percent difference requirement for T1-208, however they do meet the relative error ratio requirement with a value of 1.7828.

Qualifier information Page 16 of 37

Qualifier Reason Analyte Sample UI Data rejected due to low abundance Bismuth-212 188968003 UI Data rejected due to low abundance Cesium-134 188968002 UI Data rejected due to low abundance. Americium-241 188968001 Cesium- 134 188968001 188968005 Niobium-94 188968006 U' Data rejected due to no valid peak Bismuth-212 1201369954 UI Data rejected due to no valid peak. 188968005 188968006 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the.

data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date: qAAA/d7 )-

Page 17 of 37

SAMPLE DATA

SUMMARY

Page 18 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-0198 GEL Work Order: 188968 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 19 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0241 Project: YANK01204 Sample ID: 188968001 Client ID: YANKO0I Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 6.02%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.959 +/-0.194 0.0592 +/-0.194 0.118 pCi/g MJH1 07/05/07 1552 648541 1 Americium-241 U! 0.00 +/-0.0973 0.078 +/-0.0973 0:156 pCi/g

-Bismuth-212 0.564 +/-0.242 0.124 +/-0.242 0.249 pCi/g Bismuth-214 0.646 +/-0.108 0.0308 +/-0.108 0.0616 pCi/g Cesium-l134 UI 0.00 +/-0.0341 0.0228 +/-0.0341 0.0456 pCi/g Cesium-137 0.0854 +/-0.0327 0.0169 +/-0.0327 0.0338 pCi/g Cobalt-60 U -0.00273 +/-0.0203 0.0172 +/-0.0203 0.0343 pCi/g Europium-152 U -0.0444 +/-0.0673 0.0447 +/-0.0673 0.0893 pCi/g Europium-154 U -0.025 +/-0.0633 0.0526 +/-0.0633 0.105 pCi/g Europium- 155 U 0.0368 +/-0.056 0.0513 +/-0.056 0.103 pCi/g Lead-212 0.839 +/-0.0871 0.025 +/-0.0871 0.0499 pCi/g Lead-214 0.759 +/-0.108 0.032 +/-0.108 0.0641 pCi/g Manganese-54 U -0.00784 +/-0.0204 0.0169 +/-0.0204 0.0339 pCi/g Niobium-94 U 0.00556 +/-0.02 18 0.0164 +/-0.0218 0.0329 pCi/g Potassium-40 11.9 +/-1.03 0.144 +/-1.03 0.287 pCi/g Radium-226 0.646 +/-0.108 0.0308 +/-0.108 0.0616 pCi/g Silver-108m U 0.00537 +/-0.0174 0.0149 +/-0.0174 0.0298 pCi/g Thallium-208 0.292 +/-0.0521 0.0155 +/-0.0521 0.031 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

Page 20 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0241 Project: YANK01204 Sample ID: 188968001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA. Units DF Analyst Date Time Batch Mtd BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 21 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0251 Project: YANK01204 Sample ID: 188968002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 6.62%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.812 +/-0.159 0.0568 +/-0.159 0.114 pCi/g MJHI 07/05/07 1553 648541 1 Americium-241 U 0.00186 +/-0.106 0.0854 +/-0.106 0.171 pCi/g Bismuth-212 0.782 +/-0.297 0.124 +/-0.297 0.247 pCi/g Bismuth-214 0.702 +/-0.103 0.0334 +/-0.103 0.0668 pCi/g Cesium-134 UI 0.00 +/-0.035 0.023 +/-0.035 0.046 pCi/g Cesium-137 0.106 +/-0.0325 0.0185 +/-0.0325 0.037 pCi/g Cobalt-60 U 0.0105 +/-0.0235 0.0196 +/-0.0235 0.0392 pCi/g Europium-152 U -0.0046 +/-0.0589 0.0438 +/-0.0589 0.0876 pCi/g Europium-154 U -0.0469 +/-0.0657 0.0514 +/-0.0657 0.103 pCi/g Europium-155 U 0.0888 +/-0.079 0.0476 +/-0.079 0.0952 pCi/g Lead-212 0.868 +/-0.0828 0.0242 +/-0.0828 0.0483 pCi/g Lead-214 0.836 +/-0.105 0.0322 +/-0.105 0.0644 pCi/g Manganese-54 U 0.0212 +/-0.0223 0.0176 +/-0.0223 0.0352 pCi/g Niobium-94 U 0.015 +/-0.019 0.0168 +/-0.019 0.0336 pCi/g Potassium-40 12.0 +/-1.20 0.158 +/-1.20 0.316 pCi/g Radium-226 0.702 +/-0.103 0.0334 +/-0.103 0.0668 pCi/g Silver-108m U -0.0102 +/-0.0181 0.0146 +/-0.0i81 0.0292 pCi/g Thallium-208 0.255 +/-0.0478 0.0164 +/-0.0478 0.0328 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 22 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address : Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0251 Project: YANK01204 Sample ID: 188968002. Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 23 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0261 Proeect: YANK01204 Sample ID: 188968003 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-JUN-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 3.92%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 1.00 +/-0.218 0.0696 +/-0.218 0.139 pCi/g MJH1 07/05/07 1553 648541 1 Americium-241 U 0.0672 +/-0.110 0.0884 +/-0.110 0.177 pCi/g Bismuth-212 UI 0.00 +/-0.332 0.213 +/-0.332 0.425 pCi/g Bismuth-214 0.892 +/-0.131 0.0375 +/-0.131 0.0749 pCi/g Cesium-134 U 0.0373 +/-0.032 0.0246 +/-0.032 0.0491 pCi/g Cesium-137 0.106 +/-0.036 0.0225 +/-0.036 0.045 pCi/g Cobalt-60 U -0.00581 +/-0.022 0.0179 +/-0.022 0.0357 pCi/g Europium-152 U 0.0511 +/-0.0697 0.0542 +/-0.0697 0.108 pCi/g Europium-154 U -0.0164 +/-0.0877 0.0617 +/-0.0877 0.123 pCi/g Europium-155 U 0.0263 +/-0.0643 0.0555 +/-0.0643 0.111 pCi/g Lead-212 1.11 +/-0.111 0.0313 +/-0.111 0.0625 pCi/g Lead-214 0.947 +/-0.128 0.0382 +/-0.128 0.0763 pCi/g Manganese-54 U 0.0174 +/-0.0234 0.0205 +/-0.0234 0.041 pCi/g Niobium-94 U -0.0109 +/-0.02 16 0.0177 +/-0.0216 0.0354 pCi/g Potassium-40 12.9 +/-1.28 0.185 +/-1.28 0.369 pCi/g Radium-226 0.892 +/-0.131 0.0375 +/-0.131 0.0749 pCi/g Silver-108m U 0.00041 +/-0.0213 0.0178 +/-0.0213 0.0355 pCi/g Thallium-208 0.391 +/-0.0613 0.0191 +/-0.0613 0.0381 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 24 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0261 Project: YANK01204 Sample ID: 188968003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 25 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0271 Proiect: YANK01204 Sample ID: 188968004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 02-JUL-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 11%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamnma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 1.08 +/-0.216 0.0706 +/-0.216 0.141 pCi/g MJH1 07/05/07 1554 648541 1 Americium-241 U -0.0263 +/-0.113 0.0874 +/-0.113 0.175 pCi/g Bismuth-212 0.826 +/-0.263 0.133 +/-0.263 0.267 pCi/g Bismuth-214 0.815 +/-0.130 0.0379 +/-0.130 0.0757 pCi/g Cesium-134 U 0.0467 +/-0.036 0.0252 +/-0.036 0.0504 pCi/g Cesium-137 0.130 +/-0.0387 0.0191 +/-0.0387 0.0381 pCi/g Cobalt-60 U -0.0135 +/-0.0221 0.0171 +/-0.0221 0.0342 pCi/g Europium-152 U 0.0315 +/-0.0656 0.0506 +/-0.0656 0.101 pCi/g Europium-154 U -0.0463 +/-0.0706 0.0552 +/-0.0706 0.110 pCi/g Europium-155 U 0;0949 +/-0.0718 0.0549 +/-0.0718 0.110 pCi/g Lead-212 1.05 +/-0.101 0.0268 +/-0.101 0.0536 pCi/g Lead-214 0.853 +/-0.114 0.0347 +/-0.114 0.0694 pCi/g Manganese-54 U -0.00527 +/-0.0208 0.0175 +/-0.0208 0.035 pCi/g Niobium-94 U 0.00847 +/-0.0211 0.0179 +/-0.0211 0.0358 pCi/g Potassium-40 12.6 +/-1.15 0.182 +/-1.15 0.364 pCi/g Radium-226 0.815 +/-0.130 0.0379 +/-0.130 0.0757 pCi/g Silver-108m U -0.00538 +/-0.0192 0.0161 +/-0.0192 0.0322 pCi/g Thallium-208 0.387 +/-0.059 0.0172 +/-0.059 0.0345 pCi/g The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 26 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0271 Project: YANK01204 Sample ID: 188968004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservationholding time was exceeded The above sample is reported on a dry weight basis.

Page 27 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0281 Project: YANK01204 Sample ID: 188968005 Client ID: YANKOO0 Matrix: TS Vol. Recv.:

Collect Date: 02-JUL-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 10.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.23 +/-0.236 0.0783 +/-0.236 0.157 pCi/g MJH1 07/05/07 1554648541 1 Americium-241 U 0.190 +/-0.158 0.0998 +/-0.158 0.200 pCi/g Bismuth-212 UI 0.00 +/-0.316 0.167 +/-0.316 0.334 pCi/g Bismuth-214 0.901 +/-0.139 0.0371 +/-0.139 0.0742 pCi/g Cesium-134 Ul 0.00 +/-0.0374 0.0263 +/-0.0374 0.0525 pCi/g

'Cesium- 137 0.139 +/-0.037 0.0206 +/-0.037 0.0412 pCi/g Cobalt-60 U -0.0105 +/-0.0344 0.0231 +/-0.0344 0.0461 pCi/g Europium-152 U 0.0347 +/-0.0866 0.0552 +/-0.0866 0.110 pCi/g Europium-154 U -0.059 +/-0.0865 0.0665 +/-0.0865 0.133 pCi/g Europium-155 U 0.0316 +/-0.0764 0.0643 +/-0.0764 0.129 pCi/g Lead-212 1.16 +/-0.119 0.0336 +/-0.119 0.0671 pCi/g Lead-214 0.955 +/-0.143 0.0398 +/-0.143 0.0795 pCi/g Manganese-54 U -0.00307 +/-0.0284 0.0231 +/-0.0284 0.0462 pCi/g Niobium-94 U 0.00666 +/-0.0248 0.0211 +/70.0248 0.0422 pCi/g Potassium-40 12.2 +/-1.37 0.219 +/-1.37 0.437 pCi/g Radium-226 0.901 +/-0.139 0.0371 +/-0.139 0.0742 pCi/g Silver-108m U -0.00951 +/-0.0221 0.0185 +/-0.0221 0.0371 pCi/g Thallium-208 0.350 +/-0.0642 0.0217 +/-0.0642 0.0434 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 28 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Company Address: Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0281 Proiect: YANKO 1204 Sample ID: 188968005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MIA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 29 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Company Address: Haddam*Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0291 Project: YANK01204 Sample ID: 188968006 Client ID: YANKOOI Matrix: TS Vol. Recv.:

Collect Date: 02-JUL-07 Receive Date: 03-JUL-07 Collector: Client Moisture: 2.67%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.666 +/-0.156 0.0579 +/-0.156 0.116 pCi/g MJH1 07/05/07 1554 648541 1 Americium-241 U 0.0708 +/-0.0676 0.058 +/-0.0676 0.116 pCi/g Bismuth-212 UI 0.00 +/-0.230 0.115 +/-0.230 0.230 pCi/g Bismuth-214 0.482 +/-0.087 0.0301 +/-0.087 0.0602 pCi/g Cesium-134 U 0.0261 +/-0.0205 0.020 +/-0.0205 0.0401 pCi/g Cesium- 137 U 0.0271 +/-0.0268 0.0164 +/-0.0268 0.0327 pCi/g Cobalt-60 U 0.000731 +/-0.021 0.0177 +/-0.021 0.0353 pCi/g Europium-152 U 0.0272 +/-0.058 0.0466 +/-0.058 0.0931 pCi/g Europium-154 U -0.0169 +/-0.0686 0.0563 +/-0.0686 0.112 pCi/g Europium-155 U 0.040 +/-0.0613 0.0439 +/-0.0613 0.0877 pCi/g Lead-212 0.634 +/-0.0697 0.0252 +/-0.0697 0.0504 pCi/g Lead-214 0.563 +/-0.0841 0.0309 +/-0.0841 0.0618 pCi/g Manganese-54 U -0.00577 +/-0.0222 0.0162 +/-0.0222 0.0324 pCi/g Niobium-94 UI 0.00 +/-0.0303 0.0163 +/-0.0303 0.0326 pCi/g Potassium-40 10.2 +/-0.981 0.133 +/-0.981 0.266 pCi/g Radium-226 0.482 +/-0.087 0.0301 +/-/-0.087 0.0602 pCilg Silver-108m U -0.00703 +/-0.0173 0.0148 +/-0.0173 0.0296 pCi/g Thallium-208 0.198 +/-0.0409 0.0153 +/-0.0409 0.0306 pCi/g The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low Page 30 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Company Address Haddam Neck Plant 362 Injun Hollow Road Report Date: July 9, 2007 Haddam Neck, Connecticut 06424

Contact:

Mr. Rick Gault Project: Soils PO# 002332 Client Sample ID: 9520-0006-0291 Project: YANK01204 Sample ID: 188968006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 31 of 37

QUALITY CONTROL DATA Page 32 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 9, 2007 Client : Connecticut Yankee Atomic Power Page I of 5 Company Haddam Neck Plant 362 Injun Hollow Road Haddam Neck, Connecticut

Contact:

Mr. Rick Gault Workorder: 188968 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 648541 QC 1201369954 188968001 DUP Actinium-228 0.959 1.00 pCi/g 14 (0%- 20%) MJH1 07/05/07 15:56 Uncert: +/-0.194 +/-0.208 TPU: +/-0.194 +/-0.208 Americium-241 UI 0.00 U -0.011 pCi/g 149 N/A Uncert: +/-0.0973 +/-0.088 TPU: +/-0.0973 +/-0.088 Bismuth-212 0.564 UT 0.00 pCi/g 13 (0%- 100%)

Uncert: +/-0.242 +/-0.257 TPU: +/-0.242 +/-0.257 Bismuth-214 0.646 0.732 pCi/g 13 (0% - 20%)

Uncert: +/-0.108 +/-0.106 TPU: +/-0.108 +/-0.106 Cesium- 134 Ul 0.00 U 0.0242 pCi/g 69 N/A Uncert: +/-0.0341 +/-0.0434 TPU: +/-0.0341 +/-0.0434 Cesium-137 0.0854 0.0952 pCi/g 24 (0%-100%)

Uncert: +/-0.0327 +/-0.0523 TPU: +/-0.0327 +/-0.0523 Cobalt-60 U -0.00273 U 0.00491 pCi/g 23 N/A Uncert: +/-0.0203 +/-0.0247 TPU: +/-0.0203 +/-0.0247 Europium- 152 U -0.0444 U -0.0293 pCi/g 32 N/A Uncert: +/-0.0673 +/-0.0871 TPU: +/-0.0673 +/-0.0871 Europium- 154 U -0.025 U -0.0488 pCi/g 10 N/A Uncert: +/-0.0633 +/-0.0684 TPU: +/-0.0633 +/-0.0684 Europium- 155 U 0.0368 U 0.00311 pCi/g 125 N/A Uncert: +/-0.056 +/-0.0866 TPU: +/-0.056 +/-0.0866 Lead-212 0.839 0.933 pCi/g 11 (0% - 20%)

Uncert: +/-0.0871 +/-0.0961 TPU: +/-0.0871 +/-0.0961 Lead-214 0.759 0.850 pCi/g 15 (0% - 20%)

Uncert: +/-0.108 +/-0.121 TPU: +/-0.108 +/-0.121 Manganese-54 U -0.00784 U -0.00807 pCi/g 62 N/A Uncert: +/-0.0204 +/-0.0273 TPU: +/-0.0204 +/-0.0273 Niobium-94 U 0.000732 pCi/g 326 N/A U 0.00556 Uncert: +/-0.0218 +/-0.0217 Page 33 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188968 Page 2 of 5 Parmname NOM Sample Oual OC Units RPD% REC% Range AnIst Date Time Rad Gamnma Spec Batch 648541 TPU: +/-0.0218 +/-0.0217 Potassium-40 11.9 12.1 pCi/g 0 (0% - 20%)

Uncert: +/-1.03 +/-1.12 TPU: +/-1.03 +/-1.12 Radium-226 0.646 0.732 pCi/g 13 (0%- 20%)

Uncert: +/-0.108 +/-0.106 TPU: +/-0.108 +/-0.106 Silver- 108m U 0.00537 U -0.0127 pCi/g 905 N/A Uncert: +/-0.0174 +/-0.0201 TPU: +/-0.0174 +/-0.0201 Thallium-208 0.292 0.249 pCi/g 26* (0% - 20%)

Uncert: +/-0.0521 +/-0.0509 TPU: +/-0.0521 +/-0.0509 QC1201369955 LCS Actinium-228 1.38 pCi/g 07/05/07 15:56 Uncert: +/-0.379 TPU: +/-0.379 Americium-241 16.4 13.8 pCi/g 84 (75%-125%)

Uncert: +/-0.998 TPU: +/-0.998 Bismuth-212 1.61 pCi/g Uncert: +/-0.661 TPU: +/-0.661 Bismuth-214 0.913 pCi/g Uncert: +/-0.181 TPU: +/-0.181 Cesium- 134 U 0.00147 pCi/g Uncert: +/-0.0606 TPU: +/-0.0606 Cesium- 137 6.31 6.28 pCi/g 100 (75%-125%)

Uncert: +/-0.578 TPU: +/-0.578 Cobalt-60 9.23 9.72 pCi/g 105 (75%-125%)

Uncert: +/-0.605 TPU: +/-0.605 Europium- 152 U 0.0292 pCi/g Uncert: +/-0.143 TPU: +/-0.143 Europium- 154 U -0.042 pCi/g Uncert: +/-0.118 TPU: +/-0.118 Europium- 155 U 0.0589 pCi/g Uncert: +/-0.111 TPU: +/-0.111 Lead-212 1.40 pCilg Uncert: +/-0.170 TPU: +/-0.170 pCi/g Lead-214 1.01 Page 34 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder- 188968 Page 3 of 5 Parmname NOM Samnle Oual OC Units RPD % REC% Ranee Anist Date Time Rad Gamma Spec Batch 648541 Uncert: +/-0.184 TPU: +/-0.184 Manganese-54 U 0.0378 pCi/g Uncert: +/-0.0558 TPU: +/-0.0558 Niobium-94 U 0.0156 pCi/g Uncert: +/-0.0563 TPU: +/-0.0563 Potassium-40 U 0.370 pCi/g Uncert: +/-0.521 TPU: +/-0.521 Radium-226 0.913 pCi/g (75%-125%)

Uncert: +/-0.181 TPU: +/-0.181 Silver-108m U 0.000614 pCi/g Uncert: +/-0.046 TPU: +/-0.046 Thallium-208 0.441 pCi/g Uncert: +/-0.0881 TPU: +/-0.0881 QC1201369953 MB Actinium-228 U -0.0805 pCi/g 07/05/07 15:55 Uncert: +/-0.0627 TPU: +/-0.0627 Americium-241 U 0.0353 pCi/g Uncert: +/-0.0558 TPU: +/-0.0558 Bismuth-212- U 0.0205 pCi/g Uncert: +/-0.108 TPU: +/-0.108 Bismuth-214 U 0.0458 pCi/g Uncert: +/-0.0578 TPU: +/-0.0578 Cesium- 134 U 0.0073 pCi/g Uncert: +/-0.0151 TPU: +1-0.0151 Cesium-137 U 0.0179 pCi/g Uncert: +/-0.0159 TPU: +/-0.0159 Cobalt-60 U -0.00382 pCi/g Uncert: +/-0.016 TPU: +/-0.016 Europium- 152 U 0.016 pCi/g Uncert: +/-0.0371 TPU: +/-0.0371 Europium- 154 U -0.0202 pCi/g Uncert: -f-0.0471 TPU: +/-0.0471 Page 35 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188968 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Timie Rad Gamma Spec Batch 648541 Europium- 155 U -0.000141 pCi/g Uncert: +/-0.0361 TPU: +/-0.0361 Lead-212 U -0.000586 pCi/g Uncert: +/-0.0255 TPU: +/-0.0255 Lead-214 U 0.00588 pCi/g Uncert: +/-0.0337 TPU: +/-0.0337 Manganese-54 U 0.00548 pCi/g Uncert: +/-0.0142 TPU: +/-0.0142 Niobium-94 U -0.0038 pCi/g Uncert: +/-0.014 TPU: +/-0.014 Potassium-40 U 0.0544 pCi/g Uncert: +/-0.198 TPU: +/-0.198 Radium-226 U 0.0458 pCi/g Uncert: +/-0.0578 TPU: +/-0.0578 Silver-108m U -0.0145 pCi/g Uncert: +/-0.014 TPU: +/-0.014 Thallium-208 U 0.0176 pCi/g Uncert: +/-0.0215 TPU: +/-0.0215 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A RPD or %Recovery limits do not apply.

ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Gamma Spectroscopy--Uncertain identification Page 36 of 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 188968 Page 5of 5 Parnmame NOM Sample Qual QC Units RPD% REC% Range Anist Date Time UI X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 37 of 37

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

Revision 0

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Revision 0

SOUTHWEST'SITE STORAGE'AREA PRELIMINARY DATA REVIEW (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Attachment 4 Survey Unit: 9520-0006 Area Description Southwest 'Site Storage Area Classification 1.

Survey Media Surface Soils' Type of Survey Final Status Survey Number of Measurements 15 Static, 6 Judgmental STATISTICS on NON-PARAMETRIC POPULATION Cs-137 DCGLop (pCi/g): 5.38E+00 Minimum Value: 0.OOE+00 Maximum Value: 6.87E-01 Mean:, 1.21E-01 Median: 7.36E-02 Standard Deviation: .1.71E-01 Cs-137 GPS Coordinates T Sample ID Result MDA I Fraction

-2a Identified North East (Pci/g) (pCi/g) of DCGL 9520-0006-001F 236169.0 668761.2 5.30E-02 0.042 3.29E-02 +

  • ................................,............................... i .............*................

0.010 9520-0006-002F 236169.0 668799.8 7.36E-02 0.037 3.63E-02 0.014 9520-0006-003F,

........... 236135.5 -............................

.......................................... .............................. 668741.9 ..............................

2.35E-02 ................. 0.025 ,.............i"4.51 E-02. i......

.......................... ......................... 0.004 9520-0006-004F 236135.5 1 668780.5 1.77E-01 0.051 5.94E-02 + 0.033 0.017 9520-0006-005F 236135.5 I.:.

i 668819.2 .

8.93E-02

. ........ -11111 0.037 4.07E-02 +

.............................. i................................

9520-0006-006F

...................................................... 236135.5

..................... I' 668857.8

..... * ......... 1.07E-01: ."-

.............................. 0.031

............... .............. 3 46E-02 .....................

............................... + ;.......... 0.020 9520-0006-007F 236102.0 668722.5 1.11E-02 1 0.021 3.46E-02 0.002 9520-0006-008F 236102.0 668761.2 6.05E-02 0.032 3 23E-02 + 0.011 9520-0006-009F

...................................................... 236102.0

..................... ..-...... 668799.8 ...

................................ O0OOE+00 0.055 .

I.......................... ............................... 5.39E-02 ............................ :......

............................ 0.000, 9520-0006-OIOF 236102.0 *i................. 1 668838.5 2.66E-01 0.051 3.59E-02 + 0.049

............................................................. . .................................... ,................................ ............................... i .................. "............

9520-0006-011F 236102.0 668877.2 1.11E-01 0.047 3.86E-02 + 0.021 9520-0006-012F 236068.5 ..... -............................

668780.5 ............................

0.OOE+00 .. ..........................

0.031 '2.98E-02

.: I.................. . .................. 0.000 9520-0006-013F 236068.5 1. ..............................

668819.2 6.87E-01 0.078 4.26E-02 + 0.128

.................. m................................... ............................. ............................... . ............................... ................ ,,,,,,,.;...............................

9520-0006-014F 236068.5 668857.8 9.44E-02 0.050 5.59E-02 + 0.018

.................... i................................. .............................. 4 ................................. ..... ...................... . .. ............

I i........................ .......

9520-0006-015F 236035. 1 668838.5 6.80E-02 0.031 2.50E-02 -+ 0.013 0

9520-0006-015FS . .- ... ... ...

136035. 8i668 3-8.5 7068E-02 i ......................... 0.039 .....3"..............

i3.71 E-02 i ....................

+.................

0.013 REVISION 0' Page I of 3

SOUTHWEST SITE STORAGE AREA PRELIMINARY DATA REVIEW (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Attachment 4 Cs-1 37 GPS Coordinates Sample ID Result MDA Fraction 2u Identified North East (pCi/g) (pCi/g) of DCGL 9520-0006-0241 236127.59 1668743.92 8.54E-02 . 0.033 3.38E-02 + 0.016

.. .............................. .....t ....................... ............................... ...............................

9520-0006-0251

........................... . .236108.41

. . . . . . . . . . . . . .. .668843.20

. . . . . . . . . . . . . . . .1.06E-01. . . . . . . . . . . . . .. . . . .0.033 . . . . . . . . . . -... . .'3.92E-02

. . . . . . . . . . . . . . . . . . . . . . .+. . . . . . . 0.020

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236131.87 9520-0006-0261 . . . . . . . . . . . . . :. .668808.84

. . . . . . . . . . . . . ...... 1.06E-01

  • ........................ * . .0.036 b 4.50E-02

. . . . . . . . . ........ +

":.. . . . . . . . . . . . ........................... 0.020 9520-0006-0271

..................................................... 236115.99 *................................

............................... 668841.76 .............................. 1.30E-01 ,*...............................*

0.039 3.81E-02 i................................

............................... + 0.024 9520-0006-0281 236092.90 668822.91 1.39E-01 0.037 4.12E-02 + 0.026

........................... ......................................................... "................................ I E..............................

9520-0006-0291 236143.26::668773.04, 2.71 E-02 1 0.027 1i3.27E-02i +

0.005 OTHER RADIONUCLIDES Isotope 1Result R2 IMDA I[DCGLop Identified Fraction Sample ID (pCi/g) (pCi/g) (pCi/g) of DCGL 9520-0006-001F

. . . . . . . . . . . . . . . . . . . . . . . . . . .................................................................. ICo-60

. . . . . . . . . . . . . . . . I.. . 3.65E-02

. . . . . . . . . . . . . 1.. . . . . 0.024

........... . . .4.O0E-02 +

. . . . . . . . . . . . . i.............................. . . . 2.6E+00

. . . . . . . . . . . . . . . . . . .0.01..........

9520-0006-003F iEu-155 8.69E-02 0.067 1.17E-01 + 2.7E+02 0.00 9520-0006-004F iEu-155 9.66E-02 0.083 1.39E-01 + 2.7E+02 0.00

............................. ................................ ............................... 4 ............................... i............................... $...............................  ;............................... ...............................

9520-0006-005F

. . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................................ :Eu-154 i.............................. . . 7.05E-02

. . . . . . . . . . . . . .. . . . . 0.069

. . . . . . . . . . . i.. . .1.30E-01

. . . . . . . . . . . . ..-. . . . . . . . +. . . . . . . .. . . 6.3E+00

. . . . . . . . . . . . . i.. . . . . 0.01 9520-0006-006F iCs-134 3.37E-02 0.023 4.41E-02 I + 3.2E+00 0.01 9520-0006-007F iCs-134 2.30E-02 0.022 3.99E-02 + 3.2E+00 0.01

...................................................................................................................... i............................... $.............................. 4...............................  ;............................... $...............................4 .................. I..... ...-.... ............................

9520-0006-009F

...................................................................................................................... iCs-134 5.65E-02 ................................0.048 ...............................

6.62E-02 t.............................. + 3.2E+00 ...............................0.02 9520-0006-009F Co-60 1 3.17E-02 0.030 5.96E-02 + 2.6E+00 0.01 9520-0006-011 F  !Am-241 4.65E-02 0.039 6.85E-02 + 1.8E+01 0.00

.........................................................................................  :............................ i............................... *........................ 4 ................ ;:................ ............... ............... ...............

9520-0006-011F iCs-134 2.83E-02 0.028 5.23E-02 + 3.2E+00 0.01 9520-0006-011 F Co-60 I 3.95E-02 1 0.033 5.53E-02 + 2.6E+00 0.02 9520-0006-0.12F !Eu-155 6.67E-02 0.051 9.76E-02 + 2.7E+02 0.00

............................  :.......................................................................................... ............................... i-...............................  ;...........................i................$............... -... ........... ...............

9520-0006-013F iAm-241 1.19E-01 0.090 1.57E-01 + i 1.8E+01 0.01

................................................................................................................................................................... "...........................................................t............................-............................

9520-0006-014F iCs-134 4.66E-02 0.042 8.01E-02 + 3.2E+00 0.01

...................................................................................................................... i............................... .3.............................. ................................ ...............................  :.............................. . ............................. ...............

9520-0006-014F !Eu-154 1.29E-01 0.113 2.19E-01 + 6.3E+00 0.02 9520-0006-014F Eu-155 8.16E-02 0.070 i...............................

1.16E-01 t.............................. +

...................................................................................................................... i............................... ............................... -............................... .. 2.7E+02 ...............................

............................-. 0.00 9520-0006-015F iCs-134 I 2.55E-02 0.021 2.73E-02 + 3.2E+00 0.01

...................................................................................................................... . ........... ...... ............................ .. . ............................ ...i ............................... .............................. ............................... .............................

9520-0006-015F iEu-155 6.56E-02 0.059 8.63E-02 + 2.7E+02 0.00

...................................................................................................................... ,............................... *........................... ............... ............... 3............... ............... ...............

9520-0006-015F

. . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................................  !.:Mn-54

. . . . . . . . . . . . . . . .. . 1.98E-02

. . . . . . . . . . . . . -... . . . . 0.017

. . . . . . . . . . ... 2.59E-02 .

i.............................. . . . . . . . . +. . . . . . . .. . . 1.2E+01

. . . . . . . . . . . . . . . . . . .0.00..........

9520-0006-0251 iEu 155 8.88E-02 0.079 1 9.52E-02 I + 2.7E+02 0.00 9520-0006-0261 ............................... ..............................

cs-134 i3.73E°02 0.032 !4.91 E02 + 3.2E+00 0.O01 REVISION 0 Page 2 of 3

SOUTHWEST SITE STORAGE AREA PRELIMINARY DATA REVIEW (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD Attachment 4 Sample ID "

TResult Isotope 2a MDA Identified DCGLop Fraction (pCi/g) (pCi/g) (pCi/g) of DCGL 9520-0006-0271 :Cs-134, 4.67E-02 0.036 5.04E-02 + 3.2E+00 0.01 9520-0006-0271 iEu-155 I 9.49E-02 0.072 1.10E-01 + 2.7E+02 0.00

.9520-0006-0281 ii.........................

.Am-241

. . 1.90E-01

. . . . . . . . . . . . . -.. . . . .0.158

. . . . . . . . . . . . 2.OOE-01

+ .. . . 1.8E+01

. . . . . . . . . . . . . i............

0.01 9520-0006-0291 7Am241

.08E-02 0.068 1.16E-01 + I 1.8E+01 0.00 9520-0006-0291 :Cs-134 2.61E-02 0.021 4. 01E-02 + 3.2E+00 0.01 REVISION 0 Page 3 of 3

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

Revision 0

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9520-0006 Survey Unit Name: Southwest Site Storage Area Mean: 1.21E-01 pCi/g Frequency Plot For Cs-137 10 8

U 6 t0 4-2-

0- i.F I. I 1

8.59E- 1.72E- 2.58E- 3.44E- 4.29E- 5.15E- 6.01E- 6.87E-02 01 01 01 01 01 01 01 Upper End Value (pCi/g)

Upper End Observation Observation Value Frequency Frequency 8.59E-02 8 53%

1.72E-01 4 27%

2.58E-01 2 13%

3.44E-01 0 0%

4.29E-01 0 0%

5.15E-01 0 0%

6.01E-01 0 0%

6.87E-01 1 7%

Total: 15 100%

~7IIII~,&4~.

Sub itted by/D te

~NOVT'I(OiAJI A -711o107 Reviewked by/Date 11o of 1

QUANTILE PLOT FOR CESIUM-137 Survey Unit: 9520-0006 Survey Unit Name: Southwest Site Storage Area Mean: 1.21E-01 pCi/g Quantile Plot For Cs-137 8.OOE-01 -*. .

7.00E-01 -. -, , .

. 6.00E-01 "

S5.00E-01 ----

.0 4.00E-01 ,

3.00E-01 -..

o 2.00E-01 ' '" . .

1.00E-01 - -

0.00E+00 ". . .....

0 20 40 60 80 100 Percentage Cs-137 Rank Percentage O.OOE+00 1 3.3%

O.OOE+00 2 10.0%

1.11E-02 3 16.7%

2.35E-02 4 23.3%

5.30E-02 5 30.0%

6.05E-02 ,6 36.7%

6.80E-02 7 43.3%

7.36E-02 8 50.0%

8.93E-02 9 56.7%

9.44E-02 10 63.3%

1.07E-01 11 70.0%

1.11E-01 12 76.7%.

1.77E-01 13 83.3%

2.66E-01 14 90.0%

6.87E-01 15 96.7%

7I2~03W G\OY(0j Skbmittedb W'ate

)AY' 7/12407 Revie~ked by/Date

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Revision 0

Connecticut Yankee Decommissioning Project GPP-GGGR-R5121-001 Attachment B, Health Physics Procedure Rev.CY-001 MAJOR Sign Test Calculation Sheet for Single Radionuclide Survey Area Number: 9520 Survey Unit Number: 0006 WPIR #: N/A Survey Area Name: Southwest Site Storage Classification: 2 TYPE I (aerror): 0.05 N: 15 Area Radionuclides: 1 st Radionuclide Cs-1 37 DCGL: 5.38E+00 Results 1st Weighted Sum 1-Ws Sign Radionuclide (WS)

(pCi/g) 5.30E-02 0.01 0.99 +1 7.36E-02 0.01 0.99 +1 2.35E-02 0.00 1.00 +1 1.77E-01 0.03 0.97 +1 8.93E-02 0.02 0.98 +1 1.07E-01 0.02 0.98 +1 1.11 E-02 0.00 1.00 +1 6.05E-02 0.01 0.99 +1 0.OOE+00 __0.00 1.00 +1 2.66E-01 0.05 0.95 +1 1.11E-01 0.02 0.98 +1 0.OOE+00 0.00 1.00 +1 6.87E-01 0.13 0.87 +1 9.44E-02 0.02 0.98 +1 6.80E-02 0.01 0.99 +1 Number of positive differences (S+) 15 Critical Value 11 Surveey Unit Meets the Acceptance Criteria Performed by: David Woitkow owi77 k" Date: 7/10/2007 Independent Revie, by: Date:

I Page 1 of 1

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Revision 0

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 124-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area #: 9520 Survey Unit # 0006 Survey Unit Name: Southwest Site Storage Area (non-protected area)

Sample Plan or WPIR#: N/A SML#: 9520-0006-015F Sample

Description:

Comparison of split samples collected from sample measurement location #15 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9520-0006-015F, the comparison sample was 9520-0006-015FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 6.80E-02 0.016 4 0.5 - 2.0 7.08E-02 0.019 '1.04 Y Comments/Corrective Actions: None Table is provided to show acceptance criteria used to assess split samples.

Resolution Areement Range 4-7 0.5-2.0 8-15 0.6-1.66 16 -50 0.75- 1.33 51 -200 0.80-1.25

>200 0.85-1.18 PpRfnked by: D ojtkowiak Date: Reveiwed by: Date:

I 7/9/2007 C&j"C " '/i */o 7 I,

ýýj Page 1 of 1

SOUTHWEST SITE STORAGE AREA (NON-PROTECTED AREA)

SURVEY UNIT 9520-0006 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

Revision 0

DQA Surface Soil Report Assessment Summary Site: 9520 Planner(s): Wojo Survey Unit Name: 9520-0006 Report Number: 2 Survey Unit Samples: 15 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment

Conclusion:

Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve 1 0.9

=0.8 F-.. . - - -

_ __II _ _ _I-

~0.7 0.6

  • , 0.5 S0.4

_ _ _ _ _ i _ _

, 0.3

  • _ 0.2 I_ _ _I _ __ _ _ 4 _ _

0.1 r_ 0 0 1 2 3 4 5 6 Soil Concentralon (pCi/g), hcluding background

- - Prospective Power 1-beta ... Actual Power

- LBGR i i Estimated Power

i. DCGL ---- Retrospective Power COMPASS v0.0.0 7112/2007 Page1I

1~

Final Status Survey Final Report Phase V Appendix A2 Survey- Unit Release Record 9520-0002, Southwest Site Storage Area December 2006

Book 4 06. 13

- .i i Fin al Status Survey Fin al Report Phase V App endix A3 Surv ey Unit Release Record 9520 -0003, Southwest Site Storage Area Decei nber 2006

rBook 5 &

~ 4]

Final Status Survey Final Report Phase V Appendix A4 Survey Unit Release Record 9520-0004, Southwest Site Storage Area 1December 2006

I 1

4..k Final Status Survey Final Report Phase V Appendix A5 Survey Unit Release Record 9520-0005, Southwest Site Storage Area December 2006

I rBook 7 1

Final Status Survey Final Report Phase V Appendix A6 Survey Unit Release Record 9530-0001, Central Peninsula December 2006

I twBwook 8 of 137 Final Status Survey Final Report Phase V Appendix A7 Survey Unit Release Record 9530-0002, Central Peninsula I

December 2006

I it' Eook 9 of 13 I'

Final Status Survey Final Report Phase V Appendix A8 Survey Unit Release Record 9530-0003, Central Peninsula December 2006

j 1

-~ -.~

C~oo 10 f13 Final Status Survey Final Report Phase V Appendix A9 Survey Unit Release Record 9530-0004, Central Peninsula December 2006 C0

wo 1of1-Final Status Survey Final Report Phase V Appendix Al 0 Survey Unit Release Record 9805-0000, Subsurface Area Associated with the Peninsula (Excluding Survey Area 9531) I\

December 2006

V 1-00klo Final Status Survey Final Report Phase V Appendix All Survey Unit Release Record 9807-0000, Subsurface Area Associated with the Southwest Site Storage Area December 2006 j4~ ;c4~ .- ~,,

IA