Final Status Survey Final Report Phase VII Appendix A7 Survey Unit Release Record 9312-0005, Former Radiologically Controlled Area Tank Farm May 2007 4

CYAPCO FINAL STATUS SURVEY RE-LEASE RECORD FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12~-0005 Prepared 1.

W Reviewed.Bv:

'/d Y

FSS Engineer Approved By:

I.

~t ITedi nical Support Manager Date: -jZ1 1-7 I

Date: '3/2k/

D)ate: g 13.</c? 7 Revision 0

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION...........................................

3

2.

CLASSIFICATION BASIS.................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..................................

7

4.

SURVEY DESIGN.........................................................

11

5.

SURVEY IMPLEMENTATION..........................................

14

6.

SURVEY RESULTS.......................................................

15

7.

QUALITY CONTROL.....................................................

22

8.

INVESTIGATIONS AND RESULTS....................................

22

9.

REMEDIATION AND RESULTS........................................

24

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN.......... 25
11. DATA QUALITY ASSESSMENT (DQA)...............................

25

12. ANOMALIES...............................................................

26

13. CONCLUSION.............................................................

26

14. ATTACHMENTS...........................................................

26 14.1 Attachment 1 - Figures (13 pages including cover) 14.2 Attachment 2 - Scan Results (6 pages including cover) 14.3 Attachment 3 - Laboratory Data (121 pages including cover) 14.4 Attachment 4 - DQA Results (19 pages including covers)

TOTAL 185 Revision 0

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9312-0005 (inside the formner Radiologically Controlled Area (RCA)) is designated as Final Status Survey (FSS) Class 1 and has an area of approximately one thousand four hundred sixty (1,460) square meters of open land and is located approximately one thousand three hundred fifty nine feet (1,359 ft) to the southeast of the site benchmark (Northing: 237370.20, Easting: 667394.57) used at Haddam Neck Plant (IJNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9312-0004 to the north (called north as oriented with the north to south flow of the Connecticut River), land Survey Unit 9312-0006 to the west, land Survey Unit 93 12-0001 and land Survey Unit 93 12-0002 to the south and land Survey Unit 93 12-0009 to the east.

As a result of demolition and remediation activities, the area topography is mostly flat and de-vegetated. The survey unit has a moderate slope running from east to west.

The reference coordinates associated with this survey unit are EO 11I through EO013 by S064 through S066 (refer to "HNP License Termination Plan" (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. "

The "Classification Basis Summary" conducted for Survey Unit 9312-0005 consisted of:

a) A review of the I OCFR5O.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historical Site Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed. The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP, Revision 0.

Revision 03 3

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD During plant operation, Survey Unit 9312-0005 was the location of several significant reactor support structures and systems, primarily consisting of a grouping of liquid storage tanks referred to as-the "Tank Farmn" and the Spent Resin Facility.

The Tank Farmn was an asphalt covered area located to the northeast of the former location of the Containment structure where the Refueling Water Storage Tank (RWST), the Waste Test Tanks A & B, the Aerated Drains Holdup Tank (ADHUT),

the Borated Waste Storage Tank (BWST) and the Recycle Test Tanks (RTT's) were located. Rupture-containment dikes were constructed around the bases of these tanks.

In addition, the area also contained sub-grade covered and shielded pipe trenches that housed subsurface piping and conduit associated with the tanks and other adjacent support systems. All of these tanks and systems had contained radioactive liquids over their history and were highly contaminated. Contamination levels in several of the systems were high enough to create high radiation areas in their vicinity.

The Resin Slurry and Ion Exchange Area included the "Ion Exchange Structure", the "Spent Resin Facility" and "Spent Resin Storage Facility". This area was located in the yard on the east side of the Tank Farmn. All surfaces within these areas were contaminated during facility operation. On multiple occasions, there was documentation of the loss of contamination control during filter change-outs and resin processing activities, resulting in the spread of alpha, beta and gamma contamination.

Samples taken in 1980 during the installation of modifications indicated the presence of significant concentrations of Cs-13 7 and Co-60 in the area of the original concrete support pad and the soil around it.

A review of the historical documentation indicated a significant number of operational events that may have impacted Survey Unit 9312-0005.

Operational events were considered to be spills and leakage from contaminated systems. These events would have had the most impact on the radiological condition of subsurface structures and footers; and the underlying soil and bedrock prior to system and structural decontamination and demolition.

Some of the major events are summarized as follows;

" Diaphragm rupture, valve failure and gasket leakage from components associated with the Refueling Water Storage Tank (RWST) resulted in documented spills of radioactive liquid into the alleyway between the Containment structure and the Primary Auxiliary Building (PAB) in November 1973, February 1976, December 1976, February 1978 and January 1979.

" A frozen degassifier line in February 1979 caused the rupture of the diaphragm disc and led to leakage of reactor cavity water into the main stack drain and subsequently onto the surrounding area in the PAB alleyway.

The report estimated a release of mixed fission and activation products onto the ground and the storm drains.

Revision 04 4

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD

  • A series of events in September 1979 resulted in the release of steam generator contents into the stack.

The steam condensed in the stack ductwork and subsequently leaked 50 to 75 gallons of contaminated water onto the alleyway.

All of the liquid was removed and the area was decontaminated.

" The degassifier rupture diaphragm actuated in December 1979 and vented gaseous contents up the stack and liquid conltents near the base of the stack. The impacted areas and systems were storm sewers, roof drain lines, stack, stack duct and drain lines and the PAB roof. All impacted areas were remediated.

  • In September of 1981 and again in October of 1981, contaminated water overflowed from the RWST hatch onto the nearby ground due to a valve misalignment and the activation of the thermo siphon heater.

" Contaminated water from RWST cleanup hoses leaked onto the alleyway in April 1990. The area was decontaminated and released.

" In September 1990 and July 1994, cracks in the welds located in the base of the RWST led to leakage of contaminated water onto the tank pedestal.

" An improperly fabricated flange led to water leakage from the RWST in November 1991 and January 1992.

" During a rainstorm in August 1997, an overflow of water from the RWST catch basin area to an uncontrolled sand area was observed.

Analysis of the water indicated H-3, Co-60 and Cs-137. The Condition Report identified the catch basin overflow as a potential source of historical tritium contamination of the yard drains and external containment mat sump.

" In June 1998, leakages from the RWST floor plates and manway port flanged joints were observed. The water accumulated around the tank foundation and trough areas on the western side of the tank. Analysis of water samples from both leaking areas identified the source of both leakages as the RWST.

" An HP survey in October 1998 revealed loose contamination at levels inside the catch containment at the base of the RWST.

Major demolition and remediation activities began in 2002.

All systems and components located inside this survey unit were removed and building structural surfaces were decontaminated to ensure contamination levels were acceptable for controlled demolition. Confirmatory radiological surveys were performed throughout the demolition process. All above grade structures were then demolished to grade.

Outside of the Containment shell, extensive soil remediation was performed in Survey Area 9312. A large excavation was created to the north of the Containment that was designated as Excavation #2.

This excavation included the area in the vicinity of the RWST and the PAB corridor. A second large excavation, designated as Excavation #1 was located over the PAB footprint. A third excavation, designated as Excavation #3 was located in the area between the Containment Building and Spent Fuel Building (SFB). Soil was excavated and removed as adjacent structures Revision 05 5

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD were demolished. This process continued until bedrock was exposed.

Subsurface structures and footings that remained following demolition and excavation include the Containment Mat, the Cable Vault wall, the Service Building east wall, a remynant of the PAB northwest wall, the Waste Disposal Building footing, the "B" Switchgear Building footing and miscellaneous fragments of footings and slabs on the bedrock.

As with the Containment basement shell, all excavations were backfilled following the performance of a radiological assessment. No above grade structures currently reside within Survey Unit 93 12-0005.

In Survey Area 9312, post-remediation soil samples were taken from the as-left surface soils under two (2) Survey and Sampling Work Plans, SSWPT-06-08-000 and SSWP-06-12-001.

Thirty-five (35) post remediation surface soil samples were collected from the various locations within Survey Area 9312. All samples were collected and analyzed by gamma spectroscopy by an approved off-site laboratory.

Ten (10) of the thirty-five (35) post remediation samples collected were analyzed for the full suite of "Hard-to-Detect" (HTD) radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 3. Statistical quantities (mean, median and standard deviation) from the 2006 post-remediation survey conducted under SSWP-06-08-000 and SSWP-06-12-001 are provided in Table 1.

Minimum Value:

1.32E-02

-5.OOE-02 Maximum Value:

1.70E+/-00 1.43E+/-00 Mean:

2.3 8E-0 I 1.08E-01 Median:

1.65E-01 1.46E-02 Standard Deviation:T

3. 1OE-0 I 2.76E-0 I A review of this sample data shows Cs-137 and Co-60 to be the primary radionuclides of concern, with both isotopes reported at fairly low concentrations.

The sample population as a whole was evaluated to assess the distribution of the detected radionuclides. The radionuclide distribution percentage for each sample in the population was calculated by dividing the concentration of each detected radionuclide by the total activity concentration in the sample, expressing the abundance of the specific nuclide in the sample compared against the total activity.

The mean radionuclide distribution was then calculated by taking the average of the individual sample distribution fractions. The results are provided in Table 2.

Revision 06 6

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD Cs-137 0.689 Co-60 0.311 No HTD radionuclides were positively identified in concentrations meeting the accepted, criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS.

The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates. While Sr-90 was not identified in the soil characterization results, it was decided to include Sr-90 as a radionuclide of concern for this survey unit as Sr-90 was prevalent in the soils prior to remediation.

Therefore, all volumetric soil samples taken as part of the survey design for this survey unit were subjected to direct analysis for Sr-90.

The FSS Engineer performed a visual inspection and walk-down during January 2007 to assess the physical condition of the survey unit, evaluate access points, travel paths and identify potentially hazardous conditions.

This survey area is affected by existing and future groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the identification of radioactive material above the Derived Concentration Guideline Levels (DCGLs), and the need for radiological remediation, it was concluded that there was some probability for residual radioactivity in concentrations greater than the DCGLs, Justifying a final survey unit classification of Class I (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5. 1-11, "Preparation of Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARS SIM).

A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Revision 07 7

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9312-0005 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1 Hiotai -H Soil +/-H ExistingG W +/-HFutureG W The total dose under the LTP criteria is twenty-five (25) mrem/yr Total Effective Dose Equivalent (TEDE) from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mremlyr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is considered impacted by future groundwater radioactive contamination, as there are underground foundations containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024).

The dose contribution from future groundwater, the third dose component, is bounded by two (2) mremlyr TEDE.

Revision 08 8

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD Equation 2 19 mrem/yrT0,,., = 15 mrem/yrs,,il + 2 mrem/yrExisting Gw+/- 2 mreml1YrFuturcGW The allowable dose for soil in this survey unit is fifteen (15) mremlyr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in fifteen (15) mremi/yr TEDE is designated as the Operational DCGL (DCGLOp), and has been established for the radionuclides of concern as provided in Table 3.

Revision 09 9

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD H-3

4. 12E+02 2.47E+02 1.65E+01 C-14 5.66E+00 3.40E+00 2.26E-01 Mn-54 1.74E+01 i.04E+0 I 6.06E-01I Fe-55 2.74E+04 1.64E+04 1.I1OE+03 Co-60 3.8 1 E+00 2.29E+00 1.52E-0 1 Ni-63 7,23E+02 4.34E+02 2.89E+01I Sr-90 1.55E+00 9.30E-01 6.20E-02 Nb-94 7.1 2E-+/-0O' 4.27E+00 2.8 5E-0 1 Tc-99 1.26E+0 1 7.56E+00 5.04E-0 1 Ag-I 08m
7. 14E+00 4.28E+00 2.86E-01I Cs-134 4.67E+00O 2.80E+00 1.87E-01 Cs-137 7.9 1E+00 4.75E+00 3.16E-01 Eu-152 1.O1E+01 6.06E+00 4.04E-01 Eu-154 9.29E+00 5.57E+00 3.72E-0 I Eu-i 55 3.92E+02 2.35E+02 1.57E+01 Pu-238 2.96E+Oi I

.78E+01

1. 18E+00 Pu-239/240 2.67E+O I 1.60E+01 1.07E+00 Am-24i 2.58E+01 1.55E+01 1.03E+00 Pu-241 8.70E+02 5.22E+02 3.48E+01I Cm-243/244 2.90E+0 1
1. 74E+O 1
1. 1 6E+00 (1)

(2)

(3)

(4)

(5)

Bold indicates those radionucidies considered Hard to Detect (HTD)

The Base Case Soil DCGL(s) are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mremlyr TEDE The Operational DCGL is equivalent to achieving fifteen (15) mremlyr TEDE The required MDC is equivalent to achieving one (1) mremlyr TEDE Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed Revision 0 110

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD Another important facet of the DQO process Is to identify the radionuclides of concern and determnine the concentration variability. Soil samples were collected in 2006 to establish the radiological condition of Survey Unit 9312-0005 for FSS.

Cs-137 and Co-60 were the two (2) gamma emitting radionuclides reported in concentrations with the potential for exceeding the release criteria.

Sr-90 was included as a radionuclide of concern due to it's prevalence in the soil prior to remediation.

The characterization data were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results.

Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans". The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137, Co-60 and Sr-90 would be the radionuclides of concern in Survey Unit 9312-0005 (refer to Section 3).

The characterization survey did not include any other additional HTD radionuclides of concern for this survey unit. As Sr-90 concentrations were determnined by direct analysis, surrogate DCGLs were not required as part of the survey design for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design.

As the survey unit is classified as a Class I surface soils area, and discrete, elevated areas of contamination was possible, the application of the Elevated Measurement Comparison (EMC) remained an option.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-I 137 as part of the sample set.

Revision 0 I I

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5. 1-11 to 0.73 to achieve a relative shift (A/cs) in the range of 1 and 3.

The resulting adjusted relative shift was 2.0.

A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARS SIM in support of the decommissioning license termination rule (I OCFR2O, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. The survey design specified, fifteen (15) surface soil samples for non-parametric statistical testing. Based upon a review of the historical information and Characterization Survey data, four additional (4) judgmental samples were taken in this survey area. One (1) judgmental sample was taken adjacent to the former location of the Waste Test Tanks, one (1) judgmental sample was taken adjacent to the former location of the RWST, one (1) judgmental sample was taken adjacent to the former location of the BWST and one (1) judgmental sample was taken adjacent to the former location of the ADHUT.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System.

These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 4.

93 12-0005-OOIF 236795.06 668657.32 9312-0005-002F 236795.06 668692.10 9312-0005-003F 236764.94 668639.92 931 2-0005-004F 236764.94 668674.71 931 2-0005-005F 236764.94 668709.49 93 12-0005-006F 236764.94 668744.28 931 2-0005-007F 236734.81 668622.53 9312-0005-008F 236734.81 668657.32 Revision 0 12

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD 93 12-0005-009F 236734.81 668692.10 9312-0005-OIOF 236734.81 668726.89 9312-0005-01 IF 236734.81 668761.67 93 12-0005-012F 236704.69 668639.92 9312-0005-013F 236704.69 668674.71 9312-0005-014F 236704.69 668709.49 9312-0005-015F 236674.56 668692.10 9312-0005-016B~1 )

236697.81 668730.02 9312-0005-017B~')

236657.88 668696.84 9312-0005-01 8B~1) 236687.95 668658.53 9312-0005-019B~l) 236718.90 668614.93 (1) B = biased - indicates judgmental sample location Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Three (3) soil samples, or about 20% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 3.

The LTP requires a minimum of 5% of the samples taken for non-parametric statistical testing be selected for QC evaluation.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Su~rvey," included the collection of one (1) soil sample for "split sample" analysis by the off-site laboratory.

This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.

The LTP specifies a required scanning coverage of 100% for outdoor Class 1 areas.

For this Class 1 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 5 provides a synopsis of the survey design.

Revision 0 113

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD Survey Unit Land Area 1,460 m2' Based on AutoCAD-LT 19 Type 1 and Type 2 errors were 19 0.05, sigma was 0. 14 pCi/g, the Number of Measurements (15 systematic grid)

LBGR was set at 0.73 to achieve a (4 Judgmental)

Relative Shift in the range of 1 and 3

Grid Spacing 10.63 mn Based on triangular grid OperaionalDCGL4.75 pCi/g Cs-137 Administratively set to achieve Opertioal CGL2.29 pCi/g Co-60 fifteen (15) mrem/yr TEDE 4.75p~ig*Cs137 The Operational DCGL meets the Soil Investigation Level 2.2 pCi/gtso-60 LTP criteria for a Class 1 survey 2.29 ~i/g o-60 unit Scan Survey Area Approximately The LTP requires 100% area Coverage 100% of the area coverage for Class 1 survey units An instrument response greater Based upon a Minimum Detectable than the Scan Count Rate (MDCR) of 2,020 cpm Scan Investigation Level MDC(DCGLEMC) and a corresponding MDCscan, of of 2,8 10 cpm plus 13.92 pCi/g Cs-137 and 3.23 pCi/g ambient Co-60 backgroundI (1) The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5.

SURVEY IMPLEMENTATION Final status survey field activities were conducted under a Final Status Survey Plan (FSSP). The FSSP package included a* detailed survey plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

A single scan area was established that constituted approximately 100% of the surface area of Survey Unit 93 12-0005. Grid lines, one (1) meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 5,640 counts per minute (cpm) up to 12,500 cpm.

Revision 0 114

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD The scan area was established and scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 100% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius circle was established around the sample flag or paint mark was scanned for elevated radiation levels.

Nineteen (19) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (H-NP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Three (3) samples (9312-0005-006F, 9312-0005-014F and 9312-0005-015F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of one (1) sample (93 12-0005-01lIF) for "split sample" analysis.

6.

SURVEY RESULTS All field survey activities were conducted between March 1, 2007 and March 14, 2007.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 6 provides an overview of the scan results for sample measurement locations.

Scan results are provided in.

Revision 0 115

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD 1

7.70 10.42 NO 2

9.56 10.95 NO 3

7.73 9.74 NO 4

7.50 10.51 NO 5

8.12 11.35 NO 6

11.70 13.31 NO 7

7.70 9.59 NO 8

6.83 9.98 NO 9

7.30 11.14 NO 10 11.80 13.91 NO 11 9.98 12.13 NO 12 6.16 9.71 NO 13 6.90 9.54 NO 14 7.01 9.55 NO 15 8.08 9.67 NO 16 (2) 8.15 11.00 NO 17 (2) 6.64 10.01 NO 18(2) 6.99 10.18 NO 19(2) 6.49 9.23 NO (I) The action level is based on a measurement in accordance with the FSS plan (MDC(DCGLEMc) of 2,8 10 cpm plus ambient background)

(2) Judgmental Sample Location The scan area, that comprised approximately 100% of the total surface area for the survey unit, was scanned for elevated radiation levels.

The area was scanned in accordance with the FSS plan on March 5, 2007.

Forty-four (44) scan strips were established in this survey unit.

No elevated measurement locations were identified during scanning.

Table 7 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

Revision 0 116

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD 1 thru 10*

12.10 14.61 None None IlIthru 20 12.40 15.31 None None 21 thru 30 7.00 9.45 None None 31lthru 40 10.30 14.01 None None 41lthru 44 11.90 14.21 None None (1) The action level is based on a measurement in accordance with the FSS plan (MDC(DCGLEMC) Of 2,8 10 cpm plus ambient background)

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits and the four (4) judgmental samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs.

Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). However, Cs-137 and Co-60 were the only two gamma-emitting radionuclides reported in any appreciable concentration.

Cs-137 was positively identified in four (4) and Co-60 was identified in two (2) of the fifteen (15) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels slightly lower than expected environmental levels for Cs-137 within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 8.

Revision 0 117

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD 93 12-0005-00OIF 3.82E-03

-1. 16E-02 9312-0005-002F 1.5 1E-03 1.74E-02 931 2-0005-003F 2.65E-02

-1.1 4E-02 9312-0005-004F 2.38E-03

-3.79E-03 931 2-0005-005F 5.86E-04

-1.63E-03 9312-0005-006F

-2.47E-02 7.33E-03 931 2-0005-007F 2.11 E-02

-8.37E-03 931 2-0005-008F 2.93E-04 2.30E-03 9312-0005-009F 8.59E-03 2.63E-03 9312-0005-01IOF 2.02E-02 9.77E-03 93 12-0005-01IIF 1.46E-02 2.48E-03 9312-0005-01 2F

-5.70E-03 8.34E-03 9312-0005-013F 1.32E-02 8.76E-04 9312-0005-014F 2.37E+00 2.6 1E+/-00 9312-0005-015SF 2.0 1E-02 6.79E-03 In addition to Cs-137 and Co-60, Sr-90 was also identified during the DQO process as a radionuclide of concern. Subsequently, all samples were subjected to analysis by gas proportional counting for Sr-90. All analyses met the required minimum MDC.

Sr-90 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in three (3) of the fifteen (15) samples collected for non-parametric statistical testing.

The results of the Sr-90 analysis for the statistical sample population are provided below in Table 9.

Revision 0 118

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD 9312-0005-001IF 2.28E-02 93 12-0005-002F 2.87E-02 93 12-0005-003F 1.87E-02 931 2-0005-004F

-1.36E-02 9312-0005-005F 4.01E-03 93 12-0005-006F

-5. 12E-03 9312-0005-007F

-1.30E-02 931 2-0005-008F 3.99E3-02 93 12-0005-009F 2.28E-02 9312-0005-01IOF 5.77E-04 9312-0005-01IIF 2.48E-02 93 12-0005-012F 1.30E-03 9312-0005-013F 9.93E-03 93 12-0005-014F 2.67E-02 9312-0005-015F 1.36E-02 In addition to Sr-90, the off-site laboratory also processed, as required by the sample plan, three (3) samples for the fuill suite of HTD radionuclides as specified in LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 3.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method.

Tc-99 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in one of the three (3) samples analyzed for HTD radionuclides.

As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.

Revision 0 119

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD For Tc-99, the Operational DCGL is 7.60 pCi/g to achieve a TEDE of fifteen (15) mrem/yr. The analytical results for Tc-99 in sample 93 12-0005-014F equated to 16.20 pCi/g or 213% of the Operational DCGL. Subsequently, Tc-99 was added as a radionuclide of concern and all soil samples for this survey unit were subjected to additional analysis for the presence of Tc-99.

No other HTD radionuclides were detected. The results of the Tc-99 analysis for the statistical sample population are provided below in Table 10.

93 12-0005-00OIF 1.64E-01 9312-0005-002F 4.1 1E-02 931 2-0005-003F 7.39E-02 93 12-0005-004F 5.84E-02 931 2-0005-005F 1.04E-0 1 93 12-0005-006F

-9.98E-02 93 12-0005-007F 1.46E-01I 9312-0005-008F 1.42E-01 93 12-0005-009F 9.90E-02 9312-0005-OIOF 8.99E-02 93 12-0005-01IIF 7.59E-02 9312-0005-012F 6.58E-03 9312-0005-013F 1.62E-01 9312-0005-014F 1.62E+/-01 9312-0005-015F

-2.41E-01 The "sum-of-fractions" or "unity rule" is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determnined to be potentially present. The combination of the fractions of each detected radionuclide against their respective Operational DCGL must be less than or equal to one (1).

Revision 0 220

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM.

SURVEY UNIT 93 12-0005 RELEASE RECORD The unity rule is:

Equation 3 C,

C2 Cý

DCGL, DCGL 2
DCGL, Where:

Cn = concentration of radionuclide n and DCGLn = DCGL of radionuclide n.

The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9312-0005 are provided in Table 10 below.

9312-0005-00OIF 9312-0005-002F 0.008 0.031

-0.039 9312-0005-003F 9312-0005-004F 9312-0005-005F 9312-0005-006F 9312-0005-007F 0.004 0.004 9312-0005-008F 0.043 0.043 9312-0005-009F 931 2-0005-OIOF 0.004 0.004 9312-0005-OIIF 9312-0005-012F-----

9312-0005-013F 9312-0005-014F 0.499 1.140 0.029 2.132 3.800 9312-0005-015F 0.004 1

10.004 (1)

(2)

"-" indicate that the radionuclide was not positively detected in the sample The Operational DCGL from Table 3 is 4.75 pCi/g for Cs-137, 2.29 pCi/g for Co-60, 0.93 pCi/g for Sr-90 and 7.60 pCi/g for Tc-99 to achieve fifteen (15) mrem/yr TEDE respectively Revision 0 221

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 9312-0005 RELEASE RECORD The analytical results for the soil sample taken from location 9312-0005-014F indicate residual radioactive material present in concentrations exceeding the individual Operational DCGLs for Co-60 and Tc-99 and exceeding the unity value of one (1). Additional samples were taken to bound the discrete area of elevated activity. The results of the bounding samples and Elevated Measurement Comparison (EMC) are presented in Section 8 of this report.

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. One sample location was selected for analysis, which exceeds the 5% minimum required by the LTP.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". Cs-137 was not detected in sufficient quantity in the field split results at location 93 12-0005-01 IF to evaluate in accordance with procedure. Evaluation using the reported results for naturally occurring K-40 resulted in acceptable agreement between the field-split results at this location.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachments 3 and 4 for data and data quality analysis results

8.

INVESTIGATIONS AND RESULTS Following a review of the analytical results for the designed sample population, it was determined that four (4) additional surface soil samples would be necessary to adequately bound the area of elevated activity identified by sample 9312-0005-01 4F.

Bounding sample locations were identified in Addendum 1 to the Final Status Survey Plan. The four (4) bounding samples were taken at a distance of one (1) meter from the location of sample number 9312-0005-014F, oriented relative to the compass points of north, east, south and west. The sample results and the results of the unity rule calculation for the radionuclides of concern in the bounding sample population are provided in Table 12 below.

9312-0005-020-I 7.48E-03 1.25E-02 1.39E-02 3.23E-01 0.043 9312-0005-021-I 1.45E-02 4.83E-03 9.37E-03 2.66E-0 1 0.035 9312-0005-022-I 1.91 E-02 2.80E-03_j1.61E-03 2.89E-0l_1 0.038 9312-0005-023-1 1.90E-02 1.43E-02_j-6.07E-04 1.95E-01 (1)

"-" indicate that the radionuclide was not positively detected in the sample (2)

The Operational DCGL from Table 3 is 4.75 pCi/g for Cs-1 37, 2.29 pCi/g for Co-60, 0.93 pCi/g for Sr-90 and 7.60 pCi/g for Tc-99 to achieve fifteen (15) mrem/yr TEDE respectively Revision 0 22

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 9312-0005 RELEASE RECORD Cs-137, Co-60 and Sr-90 were not positively identified in any of the bounding samples. Tc-99 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in three (3) of the four (4) samples, but at concentrations meeting the criteria for de-selection (i.e. a concentration that is less than 5% of the Operational DCGL for an individual radionuclide).

Subsequently, the area of elevated activity was deemed to be adequately bounded.

The Elevated Measurement Comparison (EMC) protocol was applied to the area of elevated activity in accordance with LTP Section 5.8.3 and 5.4.7.4. The value used for the area factor for each area was determined from the area bounded by the adjacent samples at or below the DCGLOP. Due to the fact that the bounding samples were taken at a distance of one (1) meter in each direction from the sample location identified as elevated, the elevated area size was determined to be four (4) square meters.

Area Factors for each radionuclide corresponding to the size of the elevated area was selected from Table 5-5, Area Factor for the Resident Farmer Scenario, in Section 5.4.7.4 of the LTP. The Area Factors selected are provided in Table 13.

Cs-137 8.98 Co-60 4.22 Sr-90 314 Tc-99 276 Using the Area Factors presented in Table 13 and the results of the soil samples, the following EMC calculation was deduced; Equation 4 (5

l'evafedl

+

J elevatedi DCGLOP (A reaFactor)x D CGLOP

+ (AreaFactor)X DCGLOP where:

J= average concentration outside of the elevated area Celevated 1,2, i= average concentration inside elevated area i The average concentration of the area within the survey unit outside of the elevated areas (6) was calculated by taking the average radionuclide concentration from all surface soil samples and subtracting the radionuclide concentration average from the elevated area. This information is presented in Table 14.

Revision 0 23

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD DCGLop (pCi/g) 4.75E+/-00 I2.29E+/-00 I9.30E-01 I 7.60E+00 Average Concentration (J) (pCi/g) 8.55E-03 2.7 1E-03 9.49E-03 f1.15E-01 Avg. Fraction of the DCGL 0.002 0.001 0.010 0.015 Avg. Unity for Balance of Survey 0.028 Unit The average concentration of the elevated area is presented in Table 15.

kibe 1 -Average Concentration f1iinteie o Eeaeie

-137

~Co-60 Sr-90

~TC99~

Area Factor 8.98 4.22 314.00 276.00 DCGLEMC (pCi/g):

4.27E+01 9.66E+00 2.92E+/-02 2.10E+03 Avg. Concentration in Elevated 2.37E+/-00 2.61 E+00 2.67E-02 1.62E+/-01 Area:

Avg. Concentration - 3:

2.36E+/-00 2.6 1E+/-00 1.72E-02 1.61E+/-01 Avg. Fraction of DCGL:

0.055 0.270 0.000 0.008 Avg. Unity for Elevated Area:

0.333 The sum of the average unity result for the elevated areas and the balance of the survey unit equates to 0.361. As this value is less than one (1), this survey unit passes the unity EMC test.

9.

REMEDIATION AND RESULTS Radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to FSS. All excavations were characterized and backfilled with "clean" fill prior to performing FSS. In the area where remediation occurred, the ground area is comprised of barren dirt with no vegetation, and the soils have been graded relatively flat to the corresponding elevation of the adjacent survey units.

The results for Cs-137 following remediation were well below the Operational DCGL provided in Table 3. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

Revision 0 224

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 9312-0005 RELEASE RECORD

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN An addendum to the FSS plan was initiated on March 14, 2006 to implement the acquisition of additional soil samples necessary to adequately bound an area of elevated activity identified by the initial sample results.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency. The sampling design had adequate power. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible.

Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.

The preliminary data review consisted of calculating basic statistical quantities (e.g.,

mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 16.

DCGL0,P:

4.75E+/-00 2.29E+/-00 9.30E-01 7.60E+00 Minimum Value:

-2.47E-02

-1. 1 6E-02

-1.36E-02

-2.41 E-01I Maximum Value:

2.37E+/-00 2.6 1E+00 3.99E-02 1.62E+/-01 Mean:

1.65E-01 1.75E-01 1.21E-02 1.13E+/-00 Median:

8.59E-03 2.48E-03 1.36E-02 8.99E-02 Standard Deviation:

6. 1 OE-0 I 6.74E-0 1 1.60E-02 4.1 7E+/-00 The range of the data, about four (4) standard deviations for all four (4) radionuclides, was not a particularly large variation. The single area of elevated activity represented by sample location 9312-0005-014F caused the data set to skew positively as represented by a calculated skew of 3.87 for Cs-137, Co-60 and Tc-99.

The calculated skew for Sr-90 is -0.15.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot.

All data, assessments, and graphical representations are provided in Attachment 4.

Revision 0 225

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD

12.

ANOMALIES Analysis of the surface soil sample taken from location 9312-0005-014F indicated the presence of Co-60 at a concentration greater than the Operational DCGL for Co-60 and Tc-99 at a concentration three (3) times the Operational DCGL for Tc-99. Scan surveys of the area and subsequent bounding soil samples indicate that no additional discrete areas exhibiting elevated activity were present.

13.

CONCLUSION Survey Unit 93 12-0005 has met the final DQOs of the FSS plan.

The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

An EMC calculation was performed for an area of elevated activity in accordance with LTP Section 5.8.3 and Equation 4 of this report. The results indicated that the area was less than unity. No further action is warranted. See Tables 13 through 16 of this report for specific information with regard to the EMC calculation.

All identified radionuclides of concern were used for statistical testing to determnine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test.

The null hypothesis was rejected with adequate power. The survey unit is properly designated as Class 1.

The dose contribution from soil is 4.11 mremlyr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mremlyr TEDE.

This survey unit is considered impacted by future groundwater radioactive contamination, as there are underground foundations containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is bounded by two (2) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity will not exceed 8.11 mrem/yr TEDE. Therefore, Survey Unit 93 12-0005 is acceptable for unrestricted release.

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 26

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 1 (FIGURES)

Revision 0

- OWtLin1 0

5(0) 0(X)

NON QMWW"io NAD27CAMMOdoat SAW Ph me slyusk-Connecticuft Yankee Atomic Power Company Surmvy Unit 9312-000

I uuuO 93 12=

0004 o002 o0611 L1g~

oOtk5-000l c~o"iO 0004-9312-0002 117 0

0009

=sMquhL.AdW

-*VMI rfift 0 003

0014, b,008

-o0 7 00110 o01ý

'931 0 1

-WoLmd 0 - mhL..b 15 30 NADIVmsk

-o012, ON1$

0018 I

44.

Connecticut Yankee Atomic Power Company Sample Location Map for Survey Unit 9312-0005 D Aste: Mamh 2007 Figuiw 2 I

Reviaion 0 I

I U-UO Uzi 9312=

0004 oO. 002 oPiA015 0j,9001 cAO.04 00900-2 00.009 6O. 3020 93 12-0002 1*015 oO02 7

-0.00 o000060 9312 0001 oso (I

15 30 NO-N wDI NAW7c-oO.013

.6 o00*021 0O 00,.005 I0 0

'4 Figure 3 Connecticut Yankee Atomic Power Company 9312-00)05 Final Status Survey Design Postigg Plot for (:5-137 SDate. March2007 I

Revigiaw 0

I a

a a

(U90.07 93 12m 0004 oO.V17 o-0.012 oJ. 002 cŽ0.0 o-0. 004-c0. 003

.0.011 oO.0021 00.0O 06 93 12m 0002 0.001 O

-Smpamumorabi O ~mbLa~mb oO.0 001 o-741 008(

1;.0008 9312-009 0.003 NmrI IS J

AWN i

I H

Connctcut Yankee Atomic Power Conmpay 9312-000O5 Final Slate Survey Desi.p Posting Plot for Co-60 i

Date: Afarh 2007 Figure 4 I

Rc-viuion 0 I

9312m 0004 pq oA oi. 023 0010 01V 9312=

0002

-SMUb~omwf MDPMD

- &V14

= WELU~d o0.023

=Y'*O'NWfW 00,09

,003 dpe-o090401 o00,900 04.1013i c00,00l rC0.011 '1 fcO. 028" IS 30 rN4D27C7a*1 A~fte 5j=

Clounneccut Yankee Atomic Power Company 9312-00J05 Final Statu SWvy Design Postig Plot for Sr-90

--I Q-IJ.J (M 9312m 0004 o0. 041 0.--.1-4 ori.076 oO.164 oO.OWJ

-o&.058 9312=

0002

.1435 cO. 099 A.L 074 01 b#.142 11 O =LMOu*M ff

-WeLmeI 0

MW I'MU 30f oO.6146 o00*64, oA.142 0.00700*125 0

Figuir 6 Connecticut Yankee Atomic Plower Company 9312-000 Final Status Survy Design Postig Plot for Tc-99 I

Dfak Machv2007 I

Revisior 0 I

0.

I mm N Nfl3U T

Q9-Uo1 (R 9312m 0004

00. 041 oi104 oVi.076 oO.164 C, ",a, 9312-0002 oO.05 C09 099 CA.074 O

=SmfuzmLmmfx 0

15 30

~m~AW m

)M"Nmwamif 01 60.142, oO.146-00.1 62 7A0.125" o.oo

\\0 Connecticut Yankee Atomic Power Compay 9312-00305 Fina Statu Survey Dsig Posting Plot for Tc-99 IDBte: Match 2007 Figzure6 I

Revisiam. 0 I

0 021 014

- W&LaiI loom

=E sMurl 022 0

3 Is 30 ft" CbWWff"",W MUMCWNN"

&MAMYJ -

Connecticut Yankee Atomic Power Company Boumdin Simple Locations for 9312-000

0.0.

-2.370

.0)0-7 S001 0w-5 OO-Coo bo5sm NAU213 10*

&W&iuwqjM Figum 8 Connecticut Yankee Atlomic Power Company 9312-005FinalStatu SurveyDesig Posting Plot or Bounding Samples Cs-13 7 I

Date: Mawh 2007 I

Reviska:. 0

2.610 0.003' O

-Ebwmwi O -

-Od~

15I 30 NAD27 0 1

Figure 9 Connecticut Yankee Atomic Power Company 9312-005 Final Stalu Srvey Desij Posdng Plot for Bounding Samples Co-60 I

Date. Marh 2007 I

Revision: 0

00009-- 0.027 CW/ 0)61 0*00j

ý -0.001 O O~

o W

" - - mia 144 Figur 10 Connecticut Yankee Atomic Power Company 9312-0005 Final Stahtis Survey Dcsip Posting Plot for Bouinding Samples Sr-90 i

Date: Marh 2007 I

Revision. 0

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Revision 0

Survey Unit 9312-0005 Survey Location 931 2-05-BL-00-01 -o 931 2-05-SL-00-01 -o 931 2-05-BL-00-02-0 931 2-05-SL-00-02-0 931 2-05-B L-00-03-Q 931 2-05-SL-00-03-0 931 2-05-BL-00-04-0 9312-05-S L-00-04-0 931 2-05-BL-00-05-0 931 2-05-SL-00-05-0 931 2-05-BL-00-06-0 931 2-05-SL-00-06-0 931 2-05-BL-00-07-0 931 2-05-SL-00-07-0 931 2-05-BL-00-08-0 931 2-05-SL-00-08-0 931 2-05-BL-00-09-0 931 2-05-SL-00-09-0 9312-05-BL-00-1 0-0 931 2-05-SL-00-1 0-0 931 2-05-BL-00-1 1 -0 931 2-05-SL-00-1 1 -0 931 2-05-BL-00-1 2-0 931 2-05-SL-00-1 2-0 931 2-05-BL-00-1 3-0 931 2-05-SL-00-1 3-0 931 2-05-BL-00-14-0 931 2-05-SL-00-1 4-0 931 2-05-BL-00-1 5-0 931 2-05-SL-00-1 5-0 931 2-05-BL-00-1 6-0 931 2-05-SL-00-1 6-0 931 2-05-BL-00-1 7-0 931 2-05-SL-00-1 7-0 931 2-05-BL-00-1 8-0 931 2-05-SL-00-1 8-0 931 2-05-BL-00-1 9-0 931 2-05-SL-00-1 9-0 Log Date 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 3/1/2007 Log Time 12:55:00 12:55:00 12:56:00 12:57:00 12:58:00 12:59:00 12:59:00 13:00:00 13:01 :00 13:01 :00 13:10:00 13:11:00 13:02:00 13:03:00 13:04:00 13:04:00 13:05:00 13:05:00 13:07:00 13:07:00 13:08:00 13:09:00 13:12:00 13:13:00 13:13:00 13: 14:00 13:15:00 13:15:00 13:17:00 13:18:00 13:24:00 13:25:00 13:20:00 13:20:00 13:21 :00 13:22:00 13:22:00 13:23:00 Reading 7.61 E+03 7.70E+03 8.14E+03 9.56E+03 6.93E+03 7.73E+03 7.70E+03 7.50E+03 8.54E+03 8.12E+03 1.05E+04 1.17E+04 6.78E+03 7.70E4-03 7.17E+03 6.83E+03 8.33E+03 7.30E+03

1. 11E+04 1.18E+04 9.32E+03 9.98E+03 6.90E+03 6.16E+03 6.73E+03 6.90E+03 6.74E+03 7.01 E+03 6.86E+03 8.08E+03 8.19E+03 8.15E+03 7.20E+03
6. 64E+03 7.37E+03 6.99E+03 6.42E+03 6.49E+03 Alarm Level

>Alarm Level 1.04E+04 1.10E+04 9.74E+03 1.05E+04 1.14E+04 1.33E+04 9.59E+03 9.98E+03 1.11E+04 1.39E+04 1.21 E+04 9.71 E+03

9. 54E+03 9.55E+03 9.67E+03 1.10E+04 1.OOE+04 1.02E+04 9.23E+03 Scan Survey Results Sample Location Scans E-600 SIN Probe S/N 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 1111 1004 4/3/2007 4/3/2007Page 1 of 1

Survey Unit 9312-0005 Survey Location 931 2-05-BL-00-20-0 931 2-05-SL-00-20-0 931 2-05-BL-OO-21 -o 9312-05-SL-0O-21 -o 931 2-05-BL-00-22-0 931 2-05-SL-00-22-0 931 2-05-BL-00-23-0 931 2-05-SL-00-23-0 Scan Survey Results Investigative Sample Location Scans Log Date Log Time Reading 3/14/2007 12:53:00 7.58E+03 3/14/2007 12:54:00 7.83E+03 3/14/2007 12:54:00 6.56E+03 3/14/2007 12:55:00 8.91 E+03 3/14/2007 12:55:00 7.13E+03 3/14/2007 12:56:00 8.29E+03 3/14/2007 12:56:00 7.12E+03 3/14/2007 12:57:00 7.50E+03 Alarm

>Alarm Level Level 1.04E+04 9.37E+03 9.94E+03 9.*93E+03 E-600 S/N Probe SIN 1107 1107 1107 1107 1107 1107 1107 1107 1007 1007 1007 1007 1007 1007

.100.7 1007 4/3/2007 4/3/2007Page 1 of 1

Survey Unit 9312-0005 Survey Location 931 2-05-BC-CO-Cl -o 931 2-05-SC-CO-Cl -o 931 2-C5-BC-CO-02-O 931 2-C5-SC-OO-02-O 931 2-05-BC-CO-03-O 931 2-C5-SC-CO-03-O 931 2-C5-BC-CO-04-O 931 2-05-SC-CO-C4-O 931 2-C5-BC-CO-C5-O 931 2-05-SC-CO-OS-C 931 2-05-BC-CO-06-O 931 2-C5-SC-CO-C6-C 931 2-05-BC-CC-07-O 931 2-O5-SC-CC-07-C 931 2-05-BC-OO-08-0 931 2-O5-SC-OO-08-0 931 2-05-BC-00-09-O 931 2-05-SC-0O-09-O 931 2-05-BC-CO-i C-C 9312-05-SC-0O-iC0-0 9312-05-BC-CO-i 1 -C 9312-05-SC-CO-i 1-C 931 2-05-BC-CC-i 2-C 931 2-05-SC-CC-i 2-C 9312-05-BC-CO-i 3-0 9312-05-SC-CC-i 3-C 9312-05-BC-CO-i 4-0 9312-05-SC-CO-i 4-C 9312-05-BC-CC-i 5-C 9312-05-SC-CC-i 5-C 9312-05-BC-CC-i 6-C 9312-05-SC-CO-i 6-0 9312-05-BC-CC-i 7-C 9312-05-SC-CO-i 7-0 9312-05-BC-CO-i 8-0 931 2-05-SC-CO-i 8-0 9312-05-BC-CC-i 9-0 9312-05-SC-CC-i 9-0 931 2-C 5-BC-OC-20-O 931 2-05-SC-OC-20-O Scan Survey Results Scan Strip Scans Log Date 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/ 2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/20 07 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 Log Time 8:08:00 8:12:00 8:12:00 8:15:00 8:17:00 8:20:00 8:20:00 8:23:00 8:24:00 8:26:00 8:27:00 8:29:00 8:30:00 8:34:00 8:34:00 8:37:00 9:35:00 9:38:00 9:39:00 9:42:00 9:54:00 9:57:00 9:57:00 9:59:00 10:01:00 10:03:00 10:03:00 10:05:00 10:08:00 10:09:00 10:10:00 10:11:00 9:34:00 9:41 :00 9:42:00 9:44:00 9:45:00 9:47:00 9:48:00 9:50:00 Reading 1.02E+04 1.02E+04 9.84E+03 9.34E+03 1.09E+04 9.95E+03 1.05E+04 1.10E+04 1.04E+04 1.13E+04 9.65E+03 1.21 E+04 1.18E+04 1.07E+04 9.99E+03 1.CCE+04 1.i11E+04 9.07E+03 9.55E+03 1.11E+04 1.18E+04 1.04E+04 9.76E+03 9.51 E+03 7.97E+03 1.02E+04 1.02E+04

1. 18E+04 1.25E+04 1.24E+04 8.82E+03 8.37E+03 1.03E+04 8.65E+03 7.76E+03 6.15E+03 6.88E+03 8.12E+03 7.13E+03 6.62E+03 Alarm

>Alarm Level Level 1.30E+04 1.27E+04 1.37E+04 1.33E+04 1.32E+04 1.25E+04 1.46E+04 1.28E+04 1.39E+04 1.24E+04 1.46E+04 1.26E+04 1.08E+04 1.30E+04 1.53E+04 1.16E+04 1.31 E+04 1.06E+04 9.69E+03 9.94E+03 E-600 SIN 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1110 1110 1110 1110 1110 1110 1110 1110 Probe SIN 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1010 1010 1010 1010 1010 1010 1010 1010 4/3/2007 4/312007Page 1 of 3

Survey Unit 9312-0005 Survey Location 931 2-05-BC-00-21 -0 931 2-05-SC-00-21 -0 931 2-05-BC-00-22-0 931 2-05-SC-00-22-0 931 2-05-BC-00-23-0 931 2-05-SC-00-23-0 931 2-05-BC-00-24-0 931 2-05-SC-00-24-0 931 2-05-BC-00-25-0 931 2-05-SC-00-25-0 931 2-05-BC-00-26-0 931 2-05-SC-00-26-0 931 2-05-BC-00-27-0 931 2-05-SC-00-27-0 931 2-05-BC-00-28-0 931 2-05-S C-00-28-0 931 2-05-BC-00-29-0 931 2-05-SC-00-29-0 931 2-05-BC-00-30-0 931 2-05-SC-00-30-0 931 2-05-BC-00-3 1-0 931 2-05-SC-00-31 -0 931 2-05-BC-00-32-0 931 2-05-SC-00-32-0 931 2-05-BC-00-33-0 931 2-05-SC-00-33-0 931 2-05-BC-00-34-0 931 2-05-SC-00-34-0 931 2-05-BC-00-35-0 931 2-05-S C-00-35-0 931 2-05-BC-00-36-0 931 2-05-SC-00-36-0 931 2-05-BC-00-37-0 931 2-05-SC-00-37-0 931 2-05-BC-00-38-0 931 2-05-SC-00-38-0 931 2-05-BC-00-39-0 931 2-05-SC-00-39-0 931 2-05-BC-00-40-O 931 2-05-SC-00-40-0 Scan Survey Results Scan Strip Scans Log Date 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 3/5/2007 Log Time 9:52:00 9:54:00 9:55:00 9:57:00 9:58:00 10:01 :00 10:02:00 10:05:00 10:06:00 10:08:00 10:09:00 10:10:00 10:14:00 10:16:00 10:27:00 10:29:00 10:29:00 10:31 :00 10:32:00 10:34:00 10:35:00 10:37:00 10:37:00 10:39:00 10:40:00 10:41 :00 10:42:00 10:44:00 10:44:00 10:46:00 10:47:00 10:48:00 10:49:00 10:51:00 10:51:00 10:53:00 10:33:00 10:34:00 10:35:00 10:37:00 Reading 6.28E+03 6.66E+03 6.19E+03 6.20E+03 5.85E+03 6.32E+03

6. 34E+03 6.40E+03 6.20E+03 6.31 E+03 6.11 E+03 6.85E+03
6. 52E+03 7.OOE+03 6.15E+03 6.70E+03 6.64E+03 6.1 OE+03 6.38E+03 6.09E+03 6.48E+03 5.99E+03 5.98E+03 5.96E+03 6.31 E+03 6.96E+03 5.65E+03 5.74E+03 6.08E+03 6.01 E+03 5.90E+03 7.11 E+03 6.61 E+03 6.61 E+03 5.84 E+03 6.23E+03 1.12E+04 1.03E+04 8.85E+03 8.14E+03 Alarm

>Alarm Level Level 9.09E+03 9.OOE+03 8.66E+03 9.15E+03 9.01 E+03 8.92E+03 9.33E+03 8.96E+03 9.45E+03 9.19E+03 9.29E+03 8.79E+03 9.12 E+i03 8.46E+03 8.89E+03 8.71 E+03 9.42E+03 8.65E+03 1.40E+04 1.17E+04 E-600 SIN 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1117 1117 1117 1117 Probe SIN 1010 1010 1010 1010 1010 1010 1010 101'0 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1010 1008 1008 1008 1008 4/3/2007 4/312007Page 2 of 3

Survey Unit 9312-0005 Survey Location 931 2-05-BC-00-4 1-0 931 2-05-SC-00-4 1-0 931 2-05-BC-O0-42-0 931 2-05-SC-O0-42-0 931 2-05-BC-O0-43-0 931 2-05-SC-O0-43-0 931 2-05-BC-00-44-0 931 2-05-SC-00-44-0 Scan Survey Results Scan Strip Scans E-600 SIN Probe S/N Log Date Log Time Reading 3/5/2007 10:38:00 7.47E+03 3/5/2007 10:40:00 9.44E+03 3/5/2007 10:41:00 1.08E+04 3/5/2007 10:42:00 1.19E+04 3/5/2007 10:43:00 1.14E+04 3/5/2007 10:44:00 1.10E+04 3/5/2007 10:45:00 9.21 E+03 3/5/2007 10:48:00 8.33E+03 Alarm Level

>Alarm Level 1.03E+04 1.36E+04 1.42E+04 1.20E+04 1117 1117 1117 1117 1117 1117 1117 1117 1008 1008 1008 1008 1008 1008 1008 1008 4/3/2007 4/3/2007Page 3 of 3

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

Revision 0

General Narrative I

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 181852 SDG: MSR#07-00104 March 09, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on March 07, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 181852001 181852002 181852003 181852004 181852005 181852006 181852007 181852008 181852009 181852010 181852011 181852012 181852013 181852014 181852015 181852016 181852017 181852018 181852019 181852020 Sample Description 9312-0005-OOIF 931 2-0005-002F 931 2-0005-003F 931 2-0005-004F 931 2-0005-005F 931 2-0005-006F 931 2-0005-007F 931 2-0005-008F 931 2-0005-009F 9312-0005-01 OF 93 12-0005-01 IF 93 12-0005-011 IFS 9312-0005-012F 9312-0005-01 3F 9312-0005-014F 9312-0005-015F 9312-0005-016B 9312-0005-017B 9312-0005-01 8B 9312-0005-01 9B Items of Note There are no items to note.

GEL Laboratories L~c P0 Box 30712 Charleston, SC29417 2040 Savage Road Charleston, SC 29407 P 843.555.8171 F 843.766.1178 2

www.gel.rcom

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Seventeen soil samples were analyzed for FSSGAM and Strontium-90. Three soil samples were analyzed for FSSALL.

Data Packane The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentattion, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GEL Laboratories LLc GEL Lboraoriesu..c PO0 c30712 Chajieston, SC 29417 2040 Swavg Road Charleston, SC 29407 P 843.~556.8171 F 843.755.1178 3

www.08I.Com

List of current GEL Certifications as of 09 March 2007 State ICertification Alaska UST-062 Arizona AZ0668 Arkansas88-065 1 CLIA 42DO904046 California 0115] CA Colorado GenEngLabs Connecticut PH-01 69 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87 156 Georgia E87 156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-0I Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO1 2

________Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87 156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakot~a j

R-158 Oklahoma 9904 Pennsylvania 00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T]04704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia Washington 00151 C 1641 4

Chain of Custody and Supporting Documentation

Connecticut Yankee Atomic Power Company Chain of Custody Form N.20-07 362 Injun Hollow Road, East Hampton, CT 06424 N.N707 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

JcMcaty860-267-3924 Media Sample Container Jak c~rtyCode Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)

Prorthe:[

30 D. []15 D. Z7 D..

'V 2/

Sample Designation Date Time

14.

ý 11Comment,.Preservation Lab Sample ID 9312-0005-OOIF 3/1/07 1258 TS G

BP X___

9312-0005-002F 3/1/07 1301 TS G

BP X-9312-0005-003F 3/1/07 1303 TS G

BP X

9312-0005-004F 3/1/07 1304 TS G

BP X

9312-0005-005F 3/1/07 1305 TS G

BP X_________________

9312-0005-006F 3/1/07 1314 TS G

BP X___

9312-0005-007F 3/1/07 1306 TS G

BP X

9312-0005-008F 3/1/07 1,307 TS G

BP X

9312-0005-009F 3/1/07 1308 TS G

BP X__

9312-0005-OIOF 3/1/07 1310 TS G

BP X

NOTES: PO #: 002332 MSR #: 07- 00104 Z

LTP QA

[:1 Radwaste QA Li Non QA Samples Shipped Via; Internal Container SFed Ex Temp.:

Deg. C SHand 9~oSealed?

1)

Rei y

te/Tme 2

c vd BýDateCimeduIsdy Seal Intact?

/eel)

L Other

3) Relinquished By Date/Time
4) Received By Date/Timne

--q

'?/& W l *?of N

Bill of Lading #

Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-00072 362 Injun Hollow Road, East, Hampton, CT 06424 860-267-2556 Project Name: H-addam Neck Decommissioning Analyses Requested Lab Use ýOnly Contact Name & Phone:

Comments; JcMcaty860-267-3924 Media Sample Container Jak c~rtyCode Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Cd 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-817 1)

Priority: EL 30 D. [:] 15 D. Z 7 D.

ý Sample Designation Date Time 1

4-4 1'- 4

-Comment,. Preservation Lab Sample ID 7312-0005-01 IF 3/1/07 1312 TS G

BP X

9312-0005-01 IFS 3/1/07 1312 TS G

BP X___________________

9312-0005-012F 3/1/07 1315 TS G

BP X__________________

9312-0005-013F 3/1/07 1317 TS G

BP X

9312-0005-014F 3/1/07 1318 TS G

BP X___

9312-0005-015F 3/1/07 1319 TS G

BP X__

9312-0005-016B 3/1/07 1329 TS G

BP X

9312-0005-017B 3/1/07 1324 TS G

BP X

9312-0005-018B 3/1/07 1320 TS G

BP X

9312-0005-019B 3/1/07 1328 TS G

BP X

NOTES: P0 #: 002332 MSR 4: 07- 00104 Z LTP QA ELRadwaste QA El Non QA Samples Shipped Via:

Internal. Container 0 Fed Ex Temp.:

ýbegC ELHand dySealed?

1) Relinqui~k

~ ~

Date/Time

~

cved Bye Date/Time EOerCustd Seal Intact?

3) Relinquish4By Date/Time
4) Received By Date/Time igoig's,74 1

t

('ý'y N

Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time,

Connecticut Yankee Statement of Work for Analytical 'Lab Services Figure1. S Date/Time Received:

?Y1_

-7. l~oon SDG#-:

'Work Order NumberI 2

Shipping Cchutainer I~.I001I AM C

  • I.

Custody Seals onshipping container intac

2.

Custody Seals dated and. signed?

3.

Chain-of-Custody record pres ent?

4.

Cooler temperature

  • 5.

Verm~icuitelpacking materials is:'

6.'

Number of samles in s hipping contaier

7.

Samnple holding times exceeded?

CY-lsc-SOW-O0l ample Check-in List.

00 VOL(

Ch~ain ofCustgdy"# arLi-j -

DO6-11

.-Yes)4No[

Yes KNO[

Wet JDryt'"

Yes JNo~

9. Samples are:-

_4ý ngood condition leaking

-. broken h...Jave air bubbles

10.

Were any anomalies identified'ii sample receipt?Ye[JN P1

.sclAiptionhf of anomalies (include amp~lenubr)

Sanple. CustodiaatLaboratory:6eA Dt 8 1e2 TelephonedtoOnB 8

0 SAMPLE RECEIPT & REVIEW FORM PM use only Client: r,0171. L/a(e~, ~4kM'irn A.&.

]SDG/ARCOC-/Work Order: I~Igb -

Date Received:

-7 C%7 JPM(A) Review (ensure non-com rnlg items are resolved prior Ito signing):

,Received By:

(?

c i k

Sample Receipt Criteria Z

Comments/Qualifiers (Required for Non-Conforming Itemns).

IShipping containers received Circle Applicable: seals broken damaged container leaking container other (describe) intact and sealed?

V*

Smlsrquiring cold Circle Coolant #

ice bags blue ice dry ice other describe) 2preservation withi 'n (4 +/- 2 C)?

'go Record preservation method.

Chain of custody documents

-included with shipment?

4 Sample containers intact and Circle Applicable:, seals broken damaged container leaking container other (describe) sealed?

Sampes equiingchemcalSample ID's. containers affected and observed pH:

preservation at proper pH?_____________________________

6VOA vials free of headspace Sample ID's and containers affected:

-(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding Id's and tests affected:

8time?

9 Sample ID Is on COC match ID's Sample ID's and containers affected:

ion bottles?

10 Date & time on COG match date Sample ID's affected:

& time on bottles?___________________________

Number of containers received Sample ID's affected:

11match number indicated on COC?

COC form is properly signed in 12 relinquished/received. sections?

14Air Bill,Tracking #'s, &

14Additional Comments 6j4rp zj~

7;'t RSO RAD Receipt #___

Z

  • If > x2 area background is observed on samples identified as "non-Suspected Hazard Information reuatdno-adoctv" contact the Radiation Safety group for. further Sinvestigation.

A Radiological Classificati~on?

VMaximum Counts Observed*:

(jfCP jPCB Regulated?

Shipped as DOI Hazardous C Material? If yes, contact Waste AHazard Class Shipped:

Manager or ESH Manager.

U#

5? Regulated as a Foreign Soil?

PM (or PMA) review of Hazard classification:

Iniials Date: 3 0.

Data Review Qualifier Definitions 10

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are e5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL <sample value <PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentrat ion of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is >10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit DI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories LLc PM0 o30712 Charleston, Sc29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 543.766.1178 www.gal~com I1I

RADIOLOGICAL ANALYSIS 12

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 181852 Method/Analysis Information Product:

Aiphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Ash Soil Prep Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Dry Soil Prep 615440 615438 615437 Sample ID 181852006 181852015 181852016 1201291463 1201291464 1201291465 1201291466 Client ID 931 2-0005-006F 931 2-0005-014F 9312-0005-015F Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(931 2-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A--01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

13

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (9312-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this hatch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 14

Product:

Product:Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-I I1-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615441 615438 615437 Sample ID 18 1852006 181852015 181852016 1201291467 1201291468 1201291469 1201291470 Client ID 931 2-0005-006F 931 2-0005-014F 9312-0005-015F Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(931 2-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (93 12-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

15!

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 181852015 (9312-0005-014F) was recounted due to a suspected false positive.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I I -RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615442 615438 615437 I16

Sample ID Client ID 181852006 931 2-0005-006F 181852015 9312-0005-014F 181852016 9312-0005-015F 1201291471 Method Blank (MB) 1201291472 181852006(931 2-0005-006F) Sample Duplicate (DUP) 1201291473 181852006(9312-0005-006F) Matrix Spike (MS) 1201291474 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 181852006 (93 12-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201291471 (MB) and 1201291474 (LCS) were recounted due to quench numbers being outside of the calibration range.

17

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

EML HASL 300, 4.5.2.3 Dry Soil Prep 615799 615437 183

Sample ID 181852001 181852002 181852003 181852004 181852005 181852006 181852007 181852008 181852009 181852010 181852011 181852012 181852013 181852014 181852015 181852016 181852017 181852018 181852019 181852020 1201292386 1201292387 1201292388 Client ID 9312-0005-001lF 931 2-0005-002F 9312-0005-003 F 931 2-0005-004F 9312-0005-005 F 931 2-0005-006F 931 2-0005-007F 931 2-0005-008F 931 2-0005-009F 9312-0005-OIOF 93 12-0005-01IIF 93 12-0005-01 IFS 9312-0005-012F 9312-0005-013F 9312-0005-014F 9312-0005-015F 9312-0005-016B 9312-0005-01 7B 9312-0005-01 8B 9312-0005-01 9B Method Blank (MB) 181852001(9312-0005-001 F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852001 (93 12-0005-G0lF).

19

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set-required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The duplicate and the sample, 1201292387 (9312-0005-001IF) and 181852001 (9312-0005-001IF), did not meet the relative percent difference requirement for Ac-228, however, they do meet the relative error ratio requirement with a value of 1.087 13.

Oualifier information Qualifier Reason Analyte Sample U'

U' Data rejected due to interference.

Data rejected due to low abundance.

Europium-155 Bismuth-2 12 Cesium-134 181852011 181852002 181852005 181852008 181852009 181852013 181852014 181852016 181852019 1201292387 1201292386 181852004 Cobalt-60 Bismuth-2 12 U'

Data rejected due to no valid peak.

20

Method/Analysis Information Product:

GFPC, Sr9O, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615740.

615438 615437 Sample ID 181852001 181852002 181852003 181852004 181852005 181852006 181852007 181852008 181852009 181852010 181852011 181852012 181852013 181852014 181852015 181852016 181852017 181852018 181852019 181852020 1201292195 1201292196 1201292197 1201292198 Client ID 9312-0005-OOIF 931 2-0005-002F 931 2-0005-003F 931 2-0005-004F 931 2-0005-005F 931 2-0005-006F 931 2-0005-007F 931 2-0005-008F 931 2-0005-009F 9312-0005-OIOF 93 12-0005-01 IF 93 12-0005-011 FS 9312-0005-012F 9312-0005-01 3F 9312-0005-014F 9312-0005-015SF 9312-0005-01 6B 931 2-0005-017B 9312-0005-01 8B 9312-0005-01 9B Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(9312-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in 21

accordance with GL-RAD-A-004 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (9312-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

22

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

Analytical Batch Number:

Sample ID 181852006 181852015

.181852016 1201291721 1201291722 1201291723 1201291724 DOE EML HASL-300, Tc-02-RC Modified 615548 Client ID 931 2-0005-006F 9312-0005-014F 9312-0005-015SF Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(931 2-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (9312-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

23

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep, or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-I1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil] Prep GL-RAD-A-021 Batch Number:

Ash Soil] Prep Dry Soil Prep 615544 615438 615437 Sample ID 181852006 181852015 181852016 1201291712 1201291713 1201291714 1201291715 Client ID 931 2-0005-006F 931 2-0005-014F 9312-0005-015SF Method Blank (MB) 181852006(9312-0005-006F) Sample Duplicate (DUP) 181852006(9312-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 24

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (9312-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep, or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

25

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-i1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 615546 615438 615437 Sample [D 181852006 181852015 181852016 1201291716 1201291717 1201291718 1201291719 Client ID 931 2-0005-006F 931 2-0005-014F 9312-0005-015SF Method Blank (MB) 181 852006(9312-0005-006F) Sample Duplicate (DUP) 181852006(931 2-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information

The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 181852006 (93 12-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201291716 (MB), 181852006 (9312-0005-006F) and 181852016 (9312-0005-015F) were recounted due to a negative result greater than three times the error.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method:

EPA 906.0 Modified Analytical Batch Number:

615550 27

Sample ID 181852006 181852015 181852016 1201291725 1201291726 1201291727 1201291728 Client ID 931 2-0005-006F 931 2-0005-014F 9312-0005-015SF Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(931 2-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as'Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (9312-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation 28R

Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AII,FSS Analytical Method:

Analytical Batch Number:

Sample ID 181852006 181852015 181852016 1201291729 1201291730 1201291731 1201291732 EPA EERF C-01 Modified 615551 Client ID 931 2-0005-006F 9312-0005-01 4F 9312-0005-015SF Method Blank (MB) 181852006(931 2-0005-006F) Sample Duplicate (DUP) 181852006(9312-0005-006F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

29

Oualitv Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 181852006 (93 12-0005-006F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Gualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

30

I(4%c4&#-

Reviewer/Date:-

31

SAMPLE DATA

SUMMARY

32

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOlI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-00104 GEL Work Order: 181852 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by a3I

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

9312-0005-OOIF Project:

YANKOI1204 Sample ID:

181852001 Client ID:

YANKOOI Matrix:

TS Vol. Recv.:

Collect Date:

01-MAR-07 Receive Date:

07-MAR-07 Collector:

Client Moisture:

9.16%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch D~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.488

+/-0.206 0.0915

+/-0.206 0.183 pCi/g MJHI 03/08/07 1208 615799 Americium-24 I U -0.00779

+/-0.0369 0.029 +/-0.0369 0.058 pCi/g Bismuth-212 0.616

+/-0.326 0.165

+/-0.326 0.331 pCi/g Bismuth-214 0.439

+/-0.126 0.0398

+/-0.126 0.0796 pCi/g Cesium-I 34 U

0.0359

+/-0.0343 0.0289 +/-0.0343 0.0579 pCi/g Cesium-I 37 U

0.00382

+/-0.0273 0.0243 +/-0.0273 0.0486 pCi/g Cobalt-60 U

-0.0116

+/-0.0304 0.024 +/-0.0304 0.0479 pCi/g Europium-152 U

-0.0279

+/-0.0866 0.0494 +/-0.0866 0.0987 pCi/g Europium-154 U

0.0436

+/-0.0923 0.0816 +/-0.0923 0.163 pCi/g Europium-155 U

-0.0145

+/-0.0519 0.0454 +/-0.0519 0.0907 pCi/g Lead-212 0.546

+/-0.0722 0.027 +/-0.0722 0.054 pCi/g Lead-214 0.571

+/-0.108 0.0361

+/-0.108 0.0722 pCi/g Manganese-54 U

0.00465

+/-0.0266 0.0234 +/-0.0266 0.0467 pCi/g Niobium-94 U -0.00203

+/-0.0281 0.0211 +/-0.0281 0.0421 pCi/g Potassium-40 9.47

+/-0.935 0.203

+/-0.935 0.405 pCi/g Radium-226 0.439

+/-0.126 0.0398

+/-0.126 0.0796 pCi/g Silver-108m U 0.000965

+/-0.0207 0.018 +/-0.0207 0.036 pCi/g Thallium-208 0.208

+/-0.0555 0.021 +/-0.0555 0.0419 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0228

+/-0.0249 0.0173 +/-0.0249 0.0413 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAIJ-A-021 JMBI1 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified 34

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-OOIF Project:

YANK01204 Sample ID:

181852001 Client ID:

YANKOQI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

359

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-002F 181852002 TS 01-MAR-07 07-MAR-07 Client 9.3 1%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS CAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.529

+/-0.128 0.0498

+/-0.128 0.0995 pCilg MIHI 03/08/07 1208 615799 Americium-241 U

0.0207

+/-0.0672 0.054 +/-0.0672 0.108 pCilg Bismuth-212 UI 0.00

+/-0.142 0.132

+/-0.142 0.263 pCi/g Bismuth-214 0.455

+/-0.0808 0.0254 +/-0.0808 0.0508 pCi/g Cesium-] 34 U

0.0166

+/-0.0168 0.0155 +/-0.0168 0.031 pCi/g Cesium-]137 U

0.00151

+/-0.0158 0.0137 +/-0.0158 0.0273 pCi/g Cobalt-60 U

0.0174

+/-0.0158 0.0148 +/-0.0158 0.0296 pCi/g Europium-l152 U

-0.0498

+/-0.0567 0.0345 +/-0.0567 0.0689 pCilg Europium-154 U

-0.0114

+/-0.0472 0.0397 +/-0.0472 0.0793 pCi/g Europium-155 U

0.0295

+/-0.0493 0.0438 +/-0.0493 0.0875 pCi/g Lead-212 0.509

+/-0.0575 0.0209 +/-0.0575 0.0418 pCi/g Lead-214 0.472

+/-0.0726 0.0275 +/-0.0726 0.0549 pCi/g Manganese-54 U

0.00747

+/-0.0183 0.0141 +/-0.0183 0.0282 pCi/g Niobium-94 U

0.00758

+/-0.0153 0.0126 +/-0.0153 0.0251 pCi/g Potassium-40 11.2

+/-0.951 0.111

+/-0.951 0.223 pCi/g Radium-226 0.455

+/-0.0808 0.0254 +/-0.0808 0.0508 pCi/g Silver-108m U

0.00541

+/-0.0143 0.01 25 +/-0.0143 0.025 pCi/g Thallium-208 0.175

+/-0.0346 0.0126 +/-0.0346 0.0251 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0287

+/-0.0262 0.0175 +/-0.0262 0.0418 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 1MB]

03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/T racer recovery Test Recovery%

Acceptable Limits 36

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-002F Project:

YANK01204 Sample ID:

181852002 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 71 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 71 (25%-1 25%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy---Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-003F 181852003 TS 01-MAR-07 07-MAR-07 Client 5.33%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1P Rad Gamma Spec Analysis Gamma,So/id-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.556

+l-0.196 0.078

+/-0.196 0.156 pCi/g MJHI 03/08/07 1251 615799 Americium-241 U

-0.0013

+/-0.0455 0.0375 +/-0.0455 0.075 pCi/g Bismuth-212 U

0.347

+/-0.321 0.186

+/-0.321 0.372 pCi/g Bismuth-214 0.436

+1-0.121 0.0459

+/-0.121 0.0918 pCi/g Cesium-I 34 U

0.0356

+/-0.0376 0.0273 +/-0.0376 0.0546 pCi/g Cesium-137 U

0.0265

+/-0.0343 0.0216 +/-0.0343 0.0431 pCi/g Cobalt-60 U

-0.0114

+/-0.0291 0.0234 +/-0.0291 0.0468 pCi/g Europium-I 152 U

0.0459

+/-0.0877 0.0624 +/-0.0877 0.125 pCi/g Europium-154 U

-0.0584

+/-0.0862 0.0677 +/-0.0862 0.135 pCi/g Europium-I155 U

0.033

+/-0.0768 0.0563 +/-0.0768 0.113 pCi/g Lead-212 0.525

+/-0.0749 0.0312 +/-0.0749 0.0623 pCi/g Lead-2l4 0.467

+/-0.0978 0.0408 +/-0.0978 0.0815 pCi/g Manganese-54 U

0.0474

+/-0.0325 0.0275 +/-0.0325 0.055 pCi/g Niobium-94 U

-0.0173

+/-0.0278 0.0226 +/-0.0278 0.0451 pCi/g Potassium-40 9.89

+/-1.03 0.183

+/-1.03 0.366 pCi/g Radium-226 0.436

+/-0.121 0.0459

+/-0.121 0.0918 pCi/g Silver-1O8m U -0.00794

+/-0.0237 0.0205 +/-0.0237 0.0409 pCi/g Thallium-208 0.177

+/-0.0537 0.0204 +/-0.0537 0.0408 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0187

+/-0.0263 0.0196 +/-0.0263 0.0454 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI1 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/T racer recovery Test Recovery%

Acceptable Limits I3R

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

931 2-0005-003F Project:

YANK0 1204 Sample ID:

181852003 Client ID:

YANK00l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Strontium Carrier GFPC, Sr9O, solid-ALL FSS 85 (25%-1 25%)

Strontium Carrier GFPC, Sr9O, solid-ALL FSS 85 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

3A9C

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address 362 lnjun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-004F 181852004 TS 01-MAR-07 07-MAR-07 Client 7.84%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.569

+/-0.166 0.0724

+/-0.166 0.145 pCilg MJHI 03/08/07 1520 615799 Americium-241 U

0.0182

+/-0.0351 0.0285 +/-0.0351 0.057 pCilg Bismuth-212 UI 0.00

+/-0.332 0.159

+/-0.332 0.317 pCi/g Bismuth-214 0.329

+/-0.0868 0.0411 +/-0.0868 0.0821 pCi/g Cesium-134 U

0.00321

+/-0.0302 0.0265 +/-0.0302 0.0529 pCi/g Cesium-I 37 U

0.00238

+/-0.0263 0.0233 +/-0.0263 0.0466 pCi/g Cobalt-60 U -0.00379

+/-0.032 0.0262

+/-0.032 0.0524 pCi/g Europium-152 U

-0.0153

+/-0.0722 0.0466 +/-0.0722 0.0931 pCi/g Europium-i 54 U

-0.0147

+/-0.0912 0.0747 +/-0.0912 0.149 pCi/g Europium-155 U

0.0264

+/-0.0491 0.0442 +/-0.0491 0.0884 pCi/g Lead-2 12 0.427

+/-0.0732 0.0299 +/-0.0732 0.0597 pCi/g Lead-2 14 0.495

+/-0.0947 0.034 +/-0.0947 0.068 pCi/g Manganese-54 U-0.00043 1

+/-0.0266 0.0229 +/-0.0266 0.0458 pCi/g Niobium-94 U-0.000557

+/-0.0229 0.020 +/-0.0229 0.0401 pCi/g Potassium-40 9.67

+/-1.01 0.217

+1-I.01 0.434 pCi/g Radium-226 0.329

+/-0.0868 0.0411 +/-0.0868 0.0821 pCi/g Silver-108m U

-0.0162

+/-0.022 0.018

+/-0.022 0.0359 pCi/g Thallium-208 0.180

+/-0.0592 0.0204 +/-0.0592 0.0408 pCi/g Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Strontium-90 U

-0.0136

+/-0.0147 0.0151

+/-0.0147 0.0365 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/T racer recovery Test Recovery%

Acceptable Limits 40

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-004F Project:

YANK01204 Sample ID:

181852004 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch D~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 84 (25%-I125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 84 (25%-I125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

43-

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Anallsis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-005 F 181852005 TS 0 1-MAR-07 07-MAR-07 Client 8.7 1%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.552

+/-0.126 0.046

+/-0.126 0.092 pCi/g MIHI1 03/08/07 1523 615799 Americium-241 U -0.00413

+/-0.0671 0.0526 +/-0.0671 0.105 pCi/g Bismuth-212 0.402

+/-0.191 0.101

+/-0.191 0.202 pCi/g Bismuth-214 0.334

+/-0.0653 0.0258 +/-0.0653 0.0516 pCi/g Cesium-134 UI 0.00

+/-0.0284 0.0169 +/-0.0284 0.0337 pCi/g Cesium-]137 U 0.000586

+/-0.0167 0.0137 +/-0.0167 0.0273 pCi/g Cobalt-60 U -0.00163

+/-0.0174 0.0139 +/-0.0174 0.0277 pCi/g Europium-152 U

0.01 73

+/-0.0623 0.0381 +/-0.0623 0.0762 pCi/g Europium-154 U

-0.03

+/-0.0513 0.0418 +/-0.0513 0.0836 pCi/g Europium-ISS U

-0.0438

+/-0.052 0.0422

+/-0.052 0.0842 pCi/g Lead-21 2 0.544

+/-0.0605 0.0205 +/-0.0605 0.0409 pCi/g Lead-214 0.447

+/-0.0765 0.0266 +/-0.0765 0.0532 pCi/g Manganese-54 U-0.000829

+/-0.0164 0.0142 +/-0.0164 0.0284 pCi/g Niobium-94 U

0.022

+/-0.0153 0.0141 +/-0.0153 0.0281 pCi/g Potassium-40 10.0

+/-0.896 0.122

+/-0.896 0.244 pCi/g Radium-226 0.334

+/-0.0653 0.0258 +/-0.0653 0.0516 pCi/g Silver-108m U

0.00138

+/-0.0141 0.0121 +/-0.0141 0.0242 pCi/g Thallium-208 0.166

+/-0.0311 0.0127 +/-0.0311 0.0254 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.00401

+/-0.024 0.0196

+/-0.024 0.0451 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/T'racer recovery Test Recovery%

Acceptable Limits 42

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-005F Project:

YANK01204 Sample ID:

181852005 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1' Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 87 (25%-1 25%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

13D Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

43

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-006F 181852006 TS 01-MAR-07 07-MAR-07 Client 6.12%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Rad Alpha Spec Analysis Aiphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.0195 Curium-242 U

0.0494 Curium-243/244 U

-0.0434

+/-0.0871

+/-0.111

+/-0.0903 0.0581 0.060 0.101

+/-0.0872

+/-0.112

+/-0.0905 Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U

Plutonium-239/240 U

Liquid Scint Pu24J, Solid-ALL FSS Plutonium-241 U

Rad Gamma Spec Analysis 0.218 0.224 0.303 0.281 0.156 12.5 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g DXH2 03/08/07 0756 615440 DXH2 03/08/07 0756 615441 DXH2 03/09/07 0932 615442

-0.0703

+/-0.0784 0.100 +/-0.0788 0.0453

+/-0.0849 0.0378

+/-0.085 1.73

+/-7.14 5.90

+/-7.14 Gamma,Solid-FSS GAM & ALL FSS 226 lngrowth Waived Actinium-228 Americium-241 U -

Bismuth-2 12 Bismuth-2 14 Cesium-] 34 U

Cesium-] 37 U

Cobalt-60 U

Europium-152 U

Europium-154 U

Europium-ISS U

Lead-21 2 Lead-214 Manganese-54 U

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U

Thallium-208 Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Strontium-90 U -

Rad Liquid Scintillation Analysis LSC', Tritium Dist, Solid -

3 pCi/g Tritium U

0.594 0.00139 0.604 0.415 0.0386

-0.0247 0.00733 0.0834 0.0493 0.01 93 0.578 0.455 0.0119 0.0158 9.79 0.415 0.0 194 0.165

+/-0.192

+/-0.0436

+/-0.271

+/-0.124

+/-0.0328

+/-0.0323

+/-0.0266

+/-0.0673

+/-0.0929

+/-0.0652

+/-0.0794

+/-0.102

+/-0.0271

+/-0.0263

+/-1.05

+/-0.124

+/-0.0243

+/-0.0506 0.0854 0.0359 0.176 0.0432 0.0274 0.0238 0.023 0.0643 0.08 16 0.0578 0.0313 0.0446 0.0243 0.0231 0,183 0.0432 0.0222 0.0242

+/-0.192

+/-0.0436

+/-0. 27 1

+/-0.124

+/-0.0328

+/-0.0323

+/-0.0266

+/-0.0673

+/-0.0929

+/-0.0652

+/-0.0794

+/-0.102

+/-0.0271

+/-0.0263

+/-1.05

+/-0.124

+/-0.0243

+/-0.0506 0.171 0.07 18 0.351 0.0864 0.0547 0.0476 0.046 0.129 0.163 0.116 0.0626 0.0892 0.0486 0.0462 0.366 0.0864 0.0444 0.0484 0.0353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/eg MJHI1 03/08/07 1610 615799 KSIJI 03/12/07 1532 615740 AXD2 03/08/07 2156 615550 0.00512

+/-0.0167 0.0149 +/-0.0167

-0.322

+/-1.24 1.05

+/-1.24 2.19 44

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

931 2-0005-006F 181852006 Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOG 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 U

-0.0845

+/-0.0856 0.0737 +1-0.0856 0.151 pCi/g AXD2 03/08/07 2153 615551 Liquid Scint FeSS, Solid-ALL FSS Iron-55 U

-12

+/-44.1 30.3

+/-44.1 63.1 pCi/g MXPI 03/10/07 1858 615544 Liquid Semin Ni63, Solid-ALL FSS Nickel-63 U

-11.2

+/-10.9 9.54

+/-10.9 19.7 pCi/g MXPI 03/12/07 1748 615546 Liquid Semin Tc99, Solid-ALL FSS Technetium-99 U

-0.0998

+/-0.210 0.179

+/-0.210 0.367 pCi/g MXPI 03/12/07 1125 615548 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300, Pu-I l-RC Modified 4

EML HASL 300, 4.5-2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-I, Modified 9

DOE RESL Ni-I, Modified 10 DOE RESL Ni-I, Modified I I DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Alphaspec Am24l, Cm, Solid ALL Alphaspec Am24I, Cm, Solid ALL Aiphaspec Pu, Solid-ALL FSS Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24I, Solid-ALL F5 Liquid Scint Pu241, Solid-ALL FS 85 85 96 96 77 77 (15%-I125%)

(15%-125%)

(15%-125%)

(15%-I125%)

(25%-I125%)

(25%-I125%)

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

931 2-0005-006F 181852006 Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Strontium Carrier Strontium Carrier lron-59 Tracer Iron-59 Tracer Nickel Carrier Nickel Carrier Technetium-99m Tracer Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS GFPC, SrOO, solid-ALL ESS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL ES Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 95 95 78 78 90 90 98 98 (25%-I125%)

(25%-1 25%)

(15%-125%)

(15%-125%)

(25%-I125%)

(25%-I125%)

(15%-125%)

(15%-I 25%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-007F 181852007 TS 01-MAR-07 07-MAR-07 Client 7.12%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANK0O I Parameter Qualifier Result Ui Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.496 Americium-241 U

0.0808 Bismuth-212 0.344 Bismuth-214 0.389 Cesium-134 U

0.0179 Cesium-] 37 U

0.0211 Cobalt-60 U -0.00837 1

Europium-152 U -0.00969 Europium-154 U

-0.0122 Europium-155 U

0.0383 Lead-21 2 0.495 Lead-214 0.419 Manganese-54 U

0.01 52 Niobium-94 U

0.00233 Potassium-40 9.50 Radium-226 0.389 Silver-108m U -0.00559 Thallium-208 0.159 Rad Gas Flow Proportional Counting icertainty LC TPU

+/-0.114

-/-0.0715

+/-0.139

+/-0.059

/1-0.0191

-/-0.0132

-/-0.0124

-/-0.0409

-/-0.0385 4/-0.0407

-/-0.0504

-/-0.0607

-/-0.0146

+/-0.012

+/-0.784

+/-0.059

-/_0.0111

/I-0.0273 0.0374 0.0604 0.0797 0.01 94 0.0131 0.0111 0.00972 0.0296 0.0316 0.0322 0.0165 0.0194 0.0118 0.0103 0.0791 0.01 94 0.00954 0.0101

+/-0.114

+/-0.0715

+/-0.139

+/-0.059

+/-0.0191

+/-0.0132

+/-0.0124

+/-0.0409

+/-0.03 85

+/-0.0407

+/-0.0504

+/-0.0607

+/-0.0146

+/-0.012

+/-0.784

+/-0.059

+/-0.0111

+/-0.0273 MDA 0.0748 0.12 1 0.159 0.0388 0.0262 0.0222 0.0194 0.0591 0.0632 0.0644 0.0331 0.0388 0.0235 0.0205 0.158 0.0388 0.0191 0.0202 0.0446 Units DF Analyst Date Time Batch ý pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 03/08/07 1613 615799 KSDI 03/12/07 1532 615740 GFPC, Sr9O, solid-ALL FSS Strontium-90 U

-0.013

+/-0.0205 0.0192 +/-0.0205 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 IMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 47

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-007F Project:

YANK01204 Sample ID:

181852007 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pt Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 85 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL ESS 85 (25%-I 25%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

131 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-008F 181852008 TS 01-MAR-07 07-MAR-07 Client 4.82%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.503

+/-0.0929 0.0263 +/-0.0929 0.0526 pCi/g MIHI 03/08/07 1937 615799 Americium-241 U -0.00279

+/-0.0566 0.0471 +/-0.0566 0.0942 pCi/g Bismuth-212 0.290

+/-0.133 0.0595

+/-0.133 0.119 pCi/g Bismuth-214 0.369

+/-0.0573 0,0151 +/-0.0573 0.0301 pCi/g Cesium-134 UI 0.00

+/-0.0196 0.0101 +/-0.0196 0.0201 pCilg Cesium-137 U 0.000293

+/-0.00981 0.00839 +/-0.00981 0.0168 pCilg Cobalt-60 U

0.0023

+/-0.011 0.00824

+/-0.011 0.0165 pCi/g Europium-152 U

-0.0117

+/-0.0271 0.02 12 +/-0.0271 0.0423 pCi/g Europium-154 U

0.0173

+/-0.031 0.0274

+/-0.031 0.0548 pCi/g Europium-ISS U

0.0166

+/-0.0324 0.0264 +/-0.0324 0.0529 pCi/g Lead-212 0.528

+/-0.0502 0.0121

+/-0.0502 0.0242 pCi/g Lead-214 0.408

+/-0.0527 0.0152 +/-0.0527 0.0303 pCi/g Manganese-54 U

0.0133

+/-0.0114 0.00805 +/-0.0114 0.0161 pCi/g Niobium-94 U -0.00521

+/-0.00913 0.00756 +/-0.00913 0.0151 pCi/g Potassium-40 9.98

+/-0.702 0.0764

+/-0.702 0.153 pCi/g Radium-226 0.369

+/-0.0573 0.0151 +/-0.0573 0.0301 pCi/g Silver-108m U

-0.0 12

+/-0.00897 0.00686 +/-0.00897 0.0137 pCi/g Thallium-208 0.142

+/-0.023 0.00724

+/-0.023 0.0145 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.0399

+/-0.0286 0.0185 +/-0.0286 0.0435 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limits 49

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-008F Project:

YANK01204 SampleID:

181852008 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, SrOO, solid-ALL ESS 82 (25%-125%)

Strontium Carrier GFPC, SrOO, solid-ALL FSS 82 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-009F 18 1852009 TS 01-MAR-07 07-MAR-07 Client 4.75%

Proiect:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-229 0.390 Americium-241 U

0.0143 Bismuth-212 0.339 Bismuth-214 0.429 Cesium-134 UI 0.00 Cesium-137 U

0.00859 Cobalt-60 U

0.00263 Europium-152 U

0.0272 Europium-154 U -0.00617 Europium-ISS U

0.0301 Lead-212 0.511 Lead-214 0.452 Manganese-54 U

0.00877 Niobium-94 U -0.00697 Potassium-40 9.11 Radium-226 0.429 Silver-1O8m U -0.00771 Thallium-208 0.141 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0228

+1-0.108

+/-0.0597

+/-0.161

+/-0.0683

ý/-0.0209 F/-0.01 42 1-/-0.0 131 F/-0.0554 F/-0.0379 F/-0.0313

ý/-0.0556 F/-0.0643 F/-0.0 158 F/-0.0l 116

+/-0.742 F/-0.0683 F/-0.0 133

ý/-0.0253 0.040 0.047 0.0768 0.0207 0.0139 0.0111 0.0115 0.0291 0.0324 0.032 0.0161 0.0203 0.010 0.00977 0.100 0.0207 0.00949 0.011

+/-0.109

+/-0.0597

+/-0.161

+/-0.0683

+/-0.0209

+/-0.0142

+/-0.0131

+/-0.0554

+/-0.0379

+/-0.0313

+/-0.0556

+/-0.0643

+/-0.0158

+/-0.0116

+/-0.742

+/-0,0683

+/-0.0133

+/-0.0253 0.080 0.094 0.154 0.0414 0.0278 0.0222 0.0229 0.0581 0.0648 0.0639 0.0322 0.0407 0.020 0.01 95 0.200 0.0414 0.019 0.0219 0.048 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 03/08/07 1926 61 5799 KSDI 03/12/07 1532 615740 F/-0.0283 0.0207 +/-0.0283 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 1MB]

03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 5 1

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-009F Project:

YANK01204 Sample ID:

181852009 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 76 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 76 (25%-I 25%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

931 2-0005-OIOF 181852010 TS 01-MAR-07 07-MAR-07 Client 6%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Di Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL ['55 226 In growth Waived Actinium-228 0.740

+/-0.153 0.0381

+/-0.153 0.0762 pCi/g MJHI 03/08/07 1927 615799 Americium-241 U

0.0409

+/-0.0601 0.0499 +/-0.0601 0.0997 pCi/g Bismuth-212 0.458

+/-0.159 0.0795

+/-0.159 0.159 pCilg Bismuth-214 0.586

+/-0.0756 0.021

+/-0.0756 0.0419 pCilg Cesium-134 U

0.026

+/-0.0166 0.0137 +/-0.0166 0.0273 pCilg Cesium-137 U

0.0202

+/-0.0122 0.0106 +/-0.0122 0.0212 pCi/g Cobalt-60 U

0.00977

+/-0.0136 0.0119 +/-0.0136 0.0238 pCi/g Europium-152 U

0.0356

+/-0.0473 0.0304 +/-0.0473 0.0607 pCi/g Europium-154 U -0.00151

+/-0.0439 0.0368 +/-0.0439 0.0736 pCi/g Europium-ISS U

0.0281

+/-0.0475 0.0354 +/-0.0475 0.0707 pCi/g Lead-212 0.723

+/-0.069 0.0179

+/-0.069 0.0358 pCi/g Lead-214 0.680

+/-0.0827 0.0209 +/-0.0827 0.0417 pCi/g Manganese-54 U -0.00695

+/-0.0128 0.0108 +/-0.0128 0.0217 pCi/g Niobium-94 U

0.00509

+/-0.0123 0.0106 +/-0.0123 0.0211 pCi/g Potassium-40 12.4

+/-0.931 0.0956

+/-0.931 0.191 pCi/g Radium-226 0.586

+/-0.0756 0.021

+/-0.0756 0.0419 pCi/g Silver-108m U -0.00698

+/-0.0115 0.00983 +/-0.0115 0.0196 pCi/g Thallium-208 0.237

+/-0.0337 0.0106 +/-0.0337 0.0211 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.000577

+/-0.0249 0.0208 +/-0.0249 0.0482 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 IMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-OIOF Project:

YANK01204 Sample ID:

181852010 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Strontium Carrier GFPC, SrOO, solid-ALL ESS 71 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 71 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

54

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. 3ack McCarthy Project:

Soils P04* 002332 Report Date:

March 13, 2007 Client Sample ID:

9312-0005-01 IF Project:

YANK01204 Sample ID:

181852011 Client ID:

YANKOOI Matrix:

TS Vol. Recv.:

Collect Date:

01-MAR-07 Receive Date:

07-MAR-07 Collector:

Client Moisture:

9.39%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.577

+/-0.111 0.0359

+/-0.111 0.0717 pCi/g MJHI 03/08/07 1930 615799 Americium-241 U

0.0137

+/-0.0773 0.0627 +/-0.0773 0.125 pCi/g Bismuth-212 0.375

+/-0.198 0.0747

+/-0.198 0.149 pCi/g Bismuth-214 0.402

+/-0.0631 0.0196 +/-0.0631 0.0392 pCi/g Cesium-134 U

0.020

+/-0.0225 0.0129 +/-0.0225 0.0258 pCi/g Cesium-137 U

0.0146

+/-0.0261 0.0097 +/-0.0261 0.0194 pCi/g Cobalt-60 U

0.00248

+/-0.0127 0.0108 +/-0.0127 0.0216 pCi/g Europium-152 U

0.00579

+/-0.037 0.028

+/-0.037 0.0559 pCi/g Europium-154 U

-0.0143

+/-0.0426 0.0349 +/-0.0426 0.0699 pCi/g Europium-I 55 UI 0.00

+/-0.056 0.0315

+/-0.056 0.0631 pCi/g Lead-212 0.553

+/-0.0702 0.0161

+/-0.0702 0.0322 pCi/g Lead-214 0.456

+/-0.0654 0.0196 +/-0.0654 0.0392 pCi/g Manganese-54 U -0.00597

+/-0.01 22 0.00987 +/-0.0122 0.0197 pCi/g Niobium-94 U

0.00404

+/-0.0113 0.00977 +/-0.0113 0.0195 pCi/g Potassium-40 10.4

+/-0.854 0.0883

+/-0.854 0.177 pCi/g Radium-226 0.402

+/-0.0631 0.0196 +/-0.0631 0.0392 pCi/g Silver-108m U

0.00183

+/-0.0132 0.00908 +/-0.0132 0.0181 pCi/g Thallium-208 0.150

+/-0.0317 0.0101 +/-0.0317 0.0203 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U

0.0248

+/-0.029 0.0202

+/-0.029 0.0486 pCi/g KSDI 03/12/07 1532 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

93 12-0005-0111F Project:

YANKOI1204 Sample ID:

181852011 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GEPC, Sr90, solid-ALL FSS 61 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL ESS 61 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

93 12-0005-01IIFS 181852012 TS 01-MAR-07 07-MAR-07 Client 9.5 1%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.473

+/-0.121 0.0374

+/-0.121 0.0748 pCi/g MIHI 03/08/07 1928 615799 Americium-241 U

0.0521

+/-0.0616 0.0479 +/-0.0616 0.0957 pCi/g Bismuth-212 0.394

+/-0.173 0.0857

+/-0.173 0.171 pCi/g Bismuth-214 0.410

+/-0.0714 0.0199 +/-0.0714 0.0399 pCi/g Cesium-134 U

0.01 54

+/-0.0211 0.0142 +/-0.0211 0.0284 pCi/g Cesium-I 37 0.0242

+/-0.018 0.0111

+/-0.018 0.0221 pCi/g Cobalt-60 U

0.00214

+/-0.0145 0.0124 +1-0.0145 0.0248 pCilg Europium-152 U

0.00724

+/-0.0389 0.030 +/-0.0389 0.060 pCi/g Europium-154 U

0.0336

+/-0.0559 0.0392 +/-0.0559 0.0784 pCi/g Europium-ISS U

0.00489

+/-0.0361 0.0321

+1-0.0361 0.0642 pCi/g Lead-212 0.493

+/-0.0517 0.0168 +/-0.0517 0.0337 pCi/g Lead-214 0.467

+/-0.0725 0.021

+/-0.0725 0.0419 pCi/g Manganese-54 U

0.00363

+/-0.0151 0.0113 +/-0.0151 0.0226 pCi/g Niobium-94 U

0.0131

+/-0.0124 0.0112 +/-0.0124 0.0225 pCi/g Potassium-40 9.87

+/-0.834 0.0937

+/-0.834 0.187 pCi/g Radium-226 0.410

+/-0.0714 0.0199 +/-0.0714 0.0399 pCi/g Silver-108m U -0.00577

+/-0.0123 0.0103 +/-0.0123 0.0206 pCi/g Thallium-208 0.166

+/-0.028 0.0108

+/-0.028 0.0215 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0223

+/-0.0281 0.0205 +/-0.0281 0.0478 pCi/g KSD1 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Trracer recovery Test Recovery%

Acceptable Limits

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comn Certificate of Analysis Company :Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-01IIFS Project:

YANKOI1204 Sample ID:

181852012 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch D Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 79 (25%-1.25%)

Strontium Carrier GFPC, SrOO, solid-ALL FSS 79 (25%-1 25%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, hut not detected ahove the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

-9R

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 2F 181852013 TS 01-MAR-07 07-MAR-07 Client 6.6%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.552

+/-0.114 0.0375

+/-0.114 0.075 pCilg MJH1 03/08/07 1928 615799 Americium-241 U 0.000738

+/-0.0602 0.0497 +/-0.0602 0.0994 pCi/g Bismuth-212 0.418

+/-0.148 0.0826

+/-0.148 0.165 pCi/g Bismuth-214 0.372

+/-0.0655 0.0197 +/-0.0655 0.0394 pCi/g Cesium-I 34 UI 0.00

+/-0.0234 0.0133 +/-0.0234 0.0266 pCi/g Cesium-137 U -0.0057

+/-0.0134 0.0112 +/-0.0134 0.0223 pCi/g Cobalt-60 U

0.00834

+/-0.0146 0.0112 +/-0.0146 0.0223 pCi/g Europium-152 U

-0.006

+/-0.0355 0.0274 +/-0.0355 0.0547 pCi/g Europium-154 U -0.0209

+/-0.0396 0.0321 +/-0.0396 0.0641 pCi/g Europium-ISS U

0.0285

+/-0.0392 0.0321 +/-0.0392 0.0641 pCi/g Lead-212 0.518

+/-0.0525 0.0153 +/-0.0525 0.0305 pCi/g Lead-214 0.416

+/-0.058 0.01 94

+/-0.058 0.0388 pCi/g Manganese-54 U

0.00526

+/-0.0128 0.00961

+/-0.0128 0.0192 pCi/g Niobium-94 U

0.00204

+/-0.0115 0.00984 +/-0.0115 0.0197 pCi/g Potassium-40 9.46

+/-0.761 0.0864

+/-0.761 0.173 pCi/g Radium-226 0.372

+/-0.0655 0.0197 +/-0.0655 0.0394 pCi/g Silver-108m U -0.00251

+/-0.0106 0.00928 +/-0.0106 0.0185 pCi/g Thallium-208 0.183

+/-0.0287 0.0102 +/-0.0287 0.0205 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0013

+/-0.0222 0.0184 +/-0.0222 0.0437 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits

-99

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Client Sample ID:

9312-0005-012F Project:

YANK01204 Sample ID:

181852013 Client ID:

YANKOO I Vol. Recv.:

Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Strontium Carrier GFPCI Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 3F 181852014 TS 01-MAR-07 07-MAR-07 Client 7.6%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.527

+/-0.106 0.0353

+/-0.106 0.0705 pCi/g MJHI 03/08/07 1929 615799 Americium-241 U

0.0526

+/-0.056 0.0473

+/-0.056 0.0945 pCilg Bismuth-212 0.248

+/-0.144 0.0707

+/-0.144 0.141 pCilg Bismuth-214 0.377

+/-0.0574 0.0195 +/-0.0574 0.0389 pCilg Cesium-134 UI 0.00

+/-0.0189 0.0118 +/-0.0189 0.0236 pCilg Cesium-137 U

0.0132

+/-0.0179 0.00923 +/-0.0179 0.0185 pCilg Cobalt-60 U 0.000876

+/-0.0117

0. 00983 +/-0.0117 0.0197 pCi/g Europium-152 U

-0.0295

+/-0.0374 0.0262 +/-0.0374 0.0525 pCi/g Europium-154 U

0.0157

+/-0.040 0.0345

+/-0.040 0.0689 pCi/g Europium-ISS U

0.0201

+/-0.0364 0.0295 +/-0.0364 0.0589 pCi/g Lead-212 0.478

+/-0.0471 0.0148 +/-0.0471 0.0296 pCi/g Lead-214 0.395

+/-0.0569 0.0194 +/-0.0569 0.0388 pCi/g Manganese-54 U -0.00766

+/-0.0135 0.0104 +/-0.0135 0.0209 pCi/g Niobium-94 U -0.00213

+/-0.0121 0.00874 +/-0.0121 0.0175 pCi/g Potassium-40 9.50

+/-0.806 0.0826

+/-0.806 0.165 pCi/g Radium-226 0.377

+/-0.0574 0.0195 +/-0.0574 0.0389 pCi/g Silver-108m U -0.00361

+/-0.00984 0.00851 +/-0.00984 0.017 pCi/g Thallium-208 0.161

+/-0.0297 0.010 +/-0.0297 0.020 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.00993

+/-0.0199 0.0151

+/-0.020 0.036 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analy:sis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-013F Project:

YANK01204 Sample ID:

181852014 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 91 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils P04* 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 4F 181852015 TS 01-MAR-07 07-MAR-07 Client 4.98%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Rad Alpha Spec Analysis Aiphaspec Am24l, Cm, Solid ALL FSS Americium-241 U

0.0745 Curium-242 U

-0.0218 Curium-243/244 U

0.106

+/-0.193

+/-0.0942

+/-0.227 0.131 0.0578 0.153

+/-0.193

+/-0.0943

+/-0.227 Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U

Plutonium-239/240 U

Liquid Scint Pu24J, Solid-ALL FSS Plutonium-241 U

Rad Gamma Spec Analysis 0.382 0.239 0.426 0.303 0.373 10.5

-0.0565

+/-0.111 0.114

+/-0.112

-0.101

+/-0.144 0.149

+/-0.145

-2.03

+/-5.73 4.92

+/-5.73 Gamnma, Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.456

+/-0.134 Americium-24 I 3.93

+/-0.368 Bismuth-212 0.343

+/-0.252 Bismuth-214 0.357

+/-0.0648 Cesium-134 U

0.0142

+/-0.019 Cesium-] 37 2.37

+/-0.207 Cobalt-60 2.61

+/-0.154 Europium-1 52 U -0.00908

+/-0.0491 Europium-154 U

-0.0141

+/-0.0409 Europium-ISS U

0.0174

+/-0.0424 Lead-21 2 0.483

+/-0.0545 Lead-214 0.395

+/-0.0648 Manganese-54 U -0.00232

+/-0.0174 Niobium-94 U

0.00575

+/-0.0149 Potassium-40 9.35

+/-0.693 Radium-226 0.357

+/-0.0648 Silver-108m U-0.000583

+/-0.016 Thallium-208 0.136

+/-0.0306 Rad Gas Flow Proportional Counting 0.0592 0.0582 0.106 0.0255 0.0171 0.01 39 0.0111 0.0382 0.0338 0.0391 0.022 0.0278 0.01 52 0.0128 0.0895 0.0255 0.0141 0.0138

+/-0.134

+/-0.368

+/-0.252

+/-0.0648

+/-0.019

+/-0.207

+/-0.154

+/-0.0491

+/-0.0409

+/-0.0424

+/-0.0545

+/-0.0648

+/-0.0174

+/-0.0149

+/-0.693

+/-0.0648

+/-0.016

+/-0.0306 0.118 0.116 0.211 0.051 0.0341 0.0277 0.0222 0.0763 0.0676 0.0781I 0.044 0.0555 0.0303 0.0256 0.179 0.051 0.0282 0.0275 0.043 6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g DXH2 03/08/07 0756 615440 DXH2 03/08/07 1508 615441 DXH2 03/09/07 0948 615442 MIHI 03/08/07 1930 615799 GFPC, 5r90, solid-ALL FSS Strontium-90 U

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g 0.0267

+/-0.0267 0.0184 +/-0.0267 KSDI 03/12/07 1533 615740 Tritium Tritium

~~U

-0.747

+/-1.22 1.05

+/-1.22 2.19 pi/AX20087259650 pCi/g AXD2 03/08/07 2259 615550

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: March 13, 2007 Client Sample ID:

Sample ID:

9312-0005-014F 181852015 Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOG 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Anallyst Date Time Batch D~

Rad Liquid Scintillation Analysis Liquid Scint C04, Solid All, FSS.

Carbon-14 U

-0.051

+/-0.0881 0.0751

+/-0.0881 0.154 pCi/g AXD2 03/08/07 2254 615551 Liquid Scint FeSS, Solid-ALL FSS Iron-55 U

17.2

+/-46.6 31.4

+/-46.6 65.4 pCi/g MXP1 03/10/07 1915 615544 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-16.2

+/-12.5 10.9

+/-12.5 22.2 pCi/g MXPI 03/10/07 2143 615546 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 16.2

+/-0.503 0.184

+/-0.642 0.378 pCi/g MXP1 03/12/07 1157 615548 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-Il-RC Modified 3

DOE EML HASL-300, Pu-I1-RC Modified 4

DOE EML HASL-300, Pu-I1-RC Modified 5

EML HASL 300,4.5.2.3 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA EERF C-0lI Modified 9

DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified I1I DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Americium-243 Tracer Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Aiphaspec Am24l, Cm, Solid ALL Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24 I, Solid-ALL Fý Liquid Scint Pu24l, Solid-ALL FS 86 86 85 85 92 92 (15%-125%)

(15%-125%)

(15%-I 25%)

(15%-I125%)

(25%-I125%)

(25%-I125%)

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils P04* 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

9312-0005-01 4F 181852015 Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Strontium Carrier Strontium Carrier Iron-59 Tracer Iron-59 Tracer Nickel Carrier Nickel Carrier Technetium-99m Tracer Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 79 79 73 73 57 57 94 94 (25%-I 25%)

(25%-I 25%)

(15%-I125%)

(15%-I 25%)

(25%-I125%)

(25%-I 25%)

(15 %-125%)

(15 %-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jacli:McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-015F 181852016 TS 01-MAR-07 07-MAR-07 Client 5.93%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Rad Alpha Spec Analysis Aiphaspec Am24J, Cm, Solid ALL FSS Americium-241 U

-0.0648 Curium-242 U

0.00157 Curium-243/244 U

-0.09

+/-0.0617

+/-0.0855

+/-0.100 0.0968 0.0706 0.128

+/-0.0623

+/-0.0855

+/-0.101 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.00124 Plutonium-239/240 U

0.0395 Liquid Scint Pu24], Solid-ALL FSS Plutonium-241 U

-2.19 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.538 Americium-241 U

-0.0262 Bismuth-212 0.331 Bismuth-214 0.387 Cesium-] 34 UI 0.00 Cesium-] 37 U

0.0201 Cobalt-60 U

0.00679 Europium-1 52 U

0.00621 Europium-154 U

0.00793 Europium-ISS U

0.0283 Lead-212 0.513 Lead-214 0.462 Manganese-54 U

0.006 Niobium-94 U

0.00489 Potassium-40 9.80 Radium-226 0.387 Silver-108m U -0.00889 Thallium-208 0.161 Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Strontium-90 U

0.0136 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

-1.46

+/-0.0671 0.0554 +/-0.067 1

+I-0.0892 0.048 +/-0.0893

+/-6.21 5.33

+/-6.21

+/-0.113 i-I-0.0536

+/-0.169

+I-0.061 3

+1-0.015

+/-0.016

+/-0.0118

+/-0.0313

+/-0.0381

+/-0.0483

+/-0.0504

+/-0.0589

+/-0.0147

+/-0.0111

+/-0.785

+/-0.0613

+/-0.0112

+/-0.0287 0.0327 0.0419 0.0766 0.01 97 0.01 27 0.0104 0.01 05 0.0272 0.0331 0.030 0.0155 0.0196 0.01 05 0.00979 0.0797 0.0197 0.00915 0.0101

+/-0.113

+/-0.0536

+/-0.169

+/-0.0613

+/-0.015

+/-0.016

+/-0.0118

+/-0.0313

+/-0.0381

+/-0.0483

+/-0.0504

+/-0.0589

+/-0.0147

+/-0.0111

+/-0.785

+/-0.0613

+/-0.0112

+/-0.0287 0.297 0.248 0.359 0.195 0.180 11.3 0.0653 0.0838 0.153 0.0394 0.0253 0.0208 0.021 0.0544 0.0661 0.060 0.031 0.0392 0.0209 0.01 96 0.159 0.0394 0.0183 0.0201

0. 045 8 2.70 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g DXH2 03/08/07 0756 615441 DXH2 03/09/07 1005 615442 MJH1 03/08/07 1930 615799 KSDI 03/12/07 1533 615740 AXD2 03/09/07 0001 615550 DXH2 03/08/07 0756 615440
  • /-0.0257 0.0197 +/-0.0257

+/-1.48 1.30

+/-1.48 f;6;

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 00233?

Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

93 12-0005-015F 181852016 Project:

Client ID:

Vol. Recv.:

YANK01204 YANK00 I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Rad Liquid Scintillation Analysis Liquid Scint 014, Solid All, FSS Carbon-14 U

-0.0872

+/-0.0883 0.076 +/-0.0883 0.156 pCi/g AXD2 03/08/07 2356 615551 Liquid Scint FeSS, Solid-ALL FSS Iron-55 U

2.45

+/-48.3 32.9

+/-48.3 68.6 pCi/g MXPI 03/10/07 1931 615544 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-13.3

+/-10.9 9.59

+/-10.9 19.8 pCi/g MXPI 03/12/07 1804 615546 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

-0.241

+/-0.209 0.182

+/-0.209 0.373 pCi/g MXPI 03/12/07 1229 615548 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I1-RC Modified 3

DOE EML HASL-300, Pu-I I-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-0lI Modified 8

DOE RESL Fe-I, Modified 9

DOE RESL Ni-I, Modified 10 DOE RESL Ni-I, Modified I I DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Alphaspec Am24I, Cm, Solid ALL Alphaspec Am24I, Cm, Solid ALL Alphaspec Pu. Solid-ALL FSS Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24I, Solid-ALL Fý Liquid Scint Pu24I, Solid-ALL Fý 90 90 93 93 86 86 (15%-125%)

(15%-125%)

(15%-125%)

(15%-I125%)

(25%-1 25%)

(25%-1 25%)

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

9312-0005-015F 181852016 Project:

Client ID:

Vol. Recv.:

YANK0l1204 YANK00l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P' Strontium Carrier Strontium Carrier Iron-59 Tracer lron-59 Tracer Nickel Carrier Nickel Carrier Technetium-99m Tracer Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS GFPC, SrOO, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 77 77 74 74 88 88 95 95 (25%-I125%)

(25%-I125%)

(15%-125%)

(15%-125%)

(25%-I125%)

(25%-I 25%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 6B 181852017 TS 01-MAR-07 07-MAR-07 Client 6.94%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.473

+/-0.132 0.0487

+/-0.132 0.0974 pCi/g MJHI1 03/08/07 1931 615799 Americium-241 U

0.0128

+/-0.0271 0.0223 +/-0.0271 0.0445 pCi/g Bismuth-212 0.562

+/-0.209 0.110

+/-0.209 0.220 pCi/g Bismuth-214 0.476

+/-0.0833 0.0261 +/-0.0833 0.0522 pCi/g Cesium-]134 U

0.0218

+/-0.0198 0.0169 +/-0.0198 0.0338 pCi/g Cesium-]137 U-0.000414

+/-0.0226 0.0157 +/-0.0226 0.0314 pCi/g Cobalt-60 U

0.00939

+/-0.0168 0.0146 +/-0.0168 0.0292 pCi/g Europium-152 U

0.0403

+/-0.0582 0.0338 +/-0.0582 0.0676 pCi/g Europium-154 U

0.0348

+/-0.0568 0.043 +/-0.0568 0.0859 pCi/g Europium-ISS U

0.0463

+/-0.0468 0.0343 +/-0.0468 0.0685 pCi/g Lead-212 0.486

+/-0.0577 0.0195 +/-0.0577 0.0389 pCi/g Lead-214 0.452

+/-0.0666 0.0247 +/-0.0666 0.0494 pCi/g Manganese-54 U

0.00442

+/-0.0168 0.0149 +/-0.0168 0.0297 pCi/g Niobium-94 U -0.00775

+/-0.0159 0.0132 +/-0.0159 0.0264 pCi/g Potassium-40 9.38

+/-0.760 0.120

+/-0.760 0.239 pCi/g Radium-226 0.476

+/-0.0833 0.0261

+/-0.0833 0.0522 pCi/g Silver-108m U

0.00854

+/-0.0143 0.0128 +/-0.0143 0.0256 pCi/g Thallium-208 0.132

+/-0.0358 0.0146 +/-0.0358 0.0292 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U

0.00764

+/-0.0224 0.0176 +/-0.0224 0.0416 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 69

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Anallsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-016B Project:

YANK01204 Sample ID:

181852017 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Surrogate/T racer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 78 (25%-I125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UL Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 7B 181852018 TS 01-MAR-07 07-MAR-07 Client 5.8 1%

Proiect:

Client ID:

Vol. Recv.:

YANK01 204 YANK0OI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.594

+/-0.110 0.0346

+/-0.110 0.0692 pCi/g MIHI 03/08/07 1932 615799 Americium-241 U

0.0229

+/-0.0176 0.015 +/-0.0176 0.0301 pCi/g Bismuth-212 0.405

+/-0.166 0.0756

+/-0.166 0.151 pCi/g Bismuth-214 0.408

+/-0.0599 0.0204 +/-0.0599 0.0407 pCi/g Cesium-134 U

0.0171

+/-0.0237 0.0129 +/-0.0237 0.0257 pCi/g Cesium-137 U

0.0147

+/-0.0189 0.0102 +/-0.0189 0.0205 pCi/g Cobalt-60 U -0.00141

+/-0.0119 0.00993 +/-0.0119 0.0199 pCilg Europium-152 U

0.00206

+/-0.0343 0.0254 +/-0.0343 0.0507 pCi/g Europium-154 U

0.0255

+/-0.041 0.0358

+1-0.041 0.0716 pCilg Europium-ISS U

0.0323

+/-0.0317 0.0243 +/-0.0317 0.0486 pCi/g Lead-212 0.559

+/-0.0646 0.0147 +/-0.0646 0.0295 pCi/g Lead-214 0.492

+/-0.0628 0.0178 +/-0.0628 0.0356 pCi/g Manganese-54 U

0.0127

+/-0.00991 0.00994 +/-0.00991 0.0199 pCi/g Niobium-94 U

0.00596

+/-0.0151 0.0096 +/-0.0151 0.0192 pCilg Potassium-40 9.94

+/-0.783 0.0868

+/-0.783 0.173 pCi/g Radium-226 0.408

+/-0.0599 0.0204 +/-0.0599 0.0407 pCi/g Silver-108m U -0.00888

+/-0.0101 0.00856 +/-0.0101 0.0171 pCi/g Thallium-208 0.173

+/-0.0269 0.00969 +/-0.0269 0.0194 pCilg Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U -0.00258

+/-0.0228 0.0196 +/-0.0228 0.0464 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limits 71

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-017B Project:

YANK01204 Sample ID:

181852018 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch I Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, SrOO, solid-ALL ESS 70 (25%-125%)

Strontium Carrier GFPC, Sr90, solid-ALL FSS 70 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

72

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-01 8B 181852019 TS 01-MAR-07 07-MAR-07 Client 7.1%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOQI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL ESS 226 In growth Waived Actinium-228 0.503

+/-0.0974 0.0312 +1-0.0974 0.0623 pCi/g MIHI 03/08/07 1932 615799 Americium-241 U

0.0178

+/-0.0381 0.032 +/-0.0381 0.064 pCi/g Bismuth-212 0.276

+/-0.159 0.0713

+/-0.159 0.143 pCi/g Bismuth-214 0.353

+/-0.0558 0.0179 +/-0.0558 0.0358 pCi/g Cesium-134 UI 0.00

+/-0.0145 0.0113 +/-0.0145 0.0226 pCi/g Cesium-] 37 U

0.00515

+/-0.0137 0.0101

+/-0.0137 0.0203 pCi/g Cobalt-60 U

0.00328

+/-0.0116 0.00996 +/-0.0116 0.0199 pCi/g Europium-152 U -0.00245

+/-0.0372 0.0235 +/-0.0372 0.0469 pCi/g Europium-154 U

0.0261

+/-0.0344 0.0303 +/-0.0344 0.0606 pCi/g Europium-155 U

0.0274

+/-0.0318 0.0262 +/-0.0318 0.0525 pCi/g Lead-21 2 0.464

+/-0.0451I 0.0131 +/-0.0451 0.0262 pCi/g Lead-214 0.447

+/-0.0567 0.0161 +/-0.0567 0.0321 pCi/g Manganese-54 U

0.00849

+/-0.0097 0.00829 +/-0.0097 0.0166 pCi/g Niobium-94 U -0.00234

+/-0.0103 0.00862 +/-0.0103 0.0172 pCi/g Potassium-40 9.44

+/-0.729 0.072

+/-0.729 0.144 pCi/g Radium-226 0.353

+/-0.0558 0.0179 +/-0.0558 0.0358 pCi/g Silver-108m U -0.00499

+/-0.0094 0.00811

+/-0.0094 0.0162 pCi/g Thallium-208 0.159

+/-0.0278 0.00889 +/-0.0278 0.0178 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U

0.0281

+/-0.025 0.0169

+/-0.025 0.0399 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 71

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

March 13, 2007

.:Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-018B Project:

YANKOI1204 Sample ID:

181852019 Client ID:

YANKOOlI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr9O, solid-ALL FSS.-

78 (25%-125%)

Strontium Carrier GFPC, SrOO, solid-ALL FSS 78 (25%-I125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

74

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack MGCarthy Project:

Soils PO# 002332 Report Date:

March 13, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-019B 181852020 TS 01-MAR-07 07-MAR-07 Client 4.09%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKO0l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1P Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.556

+/-0.124 0.0441

+/-0.124 0.0882 pCilg MIHI 03/08/07 1935 615799 Americium-241 U

0.0191

+/-0.0201 0.0166 +/-0.0201 0.0331 pCi/g Bismuth-212 0.436

+/-0.197 0.0902

+/-0.197 0.180 pCi/g Bismuth-214 0.418

+/-0.072 0.0212

+/-0.072 0.0423 pCi/g Cesium-134 U

0.0236

+/-0.0164 0.0153 +/-0.0164 0.0306 pCi/g Cesium-137 U

0.00618

+/-0.0188 0.0118 +/-0.0188 0.0236 pCi/g Cobalt-60 U -0.00722

+/-0.0176 0.0143 +/-0.0176 0.0285 pCi/g Europium-152 U

-0.0138

+/-0.0592 0.0296 +/-0.0592 0.0592 pCi/g Europium-154 U

0.0145

+1-0.0501 0.043 +/-0.0501 0.086 pCi/g Europium-ISS U

0.0189

+/-0.0362 0.0248 +/-0.0362 0.0495 pCi/g Lead-212 0.497

+/-0.0547 0.0159 +/-0.0547 0.0317 pCi/g Lead-214 0.392

+/-0.0707 0.0209 +/-0.0707 0.0417 pCi/g Manganese-54 U

0.0214

+/-0.0151 0.014 +/-0.0151 0.0281 pCi/g Niobium-94 U

0.0145

+/-0.0187 0.0119 +/-0.0187 0.0237 pCi/g Potassium-40 9.59

+/-0.658 0.123

+/-0.658 0.246 pCi/g Radium-226 0.418

+/-0.072 0.0212

+/-0.072 0.0423 pCi/g Silver-108m U

-0.0172

+/-0.0142 0.00986 +/-0.0142 0.0197 pCi/g Thallium-208 0.202

+/-0.037 0.0114

+/-0.037 0.0228 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U -0.00411

+/-0.0257 0.022 +/-0.0257 0.0492 pCi/g KSDI 03/12/07 1533 615740 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 IMBI 03/07/07 1059 615437 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 75

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 13, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9312-0005-019B Project:

YANK01204 Sample ID:

181852020 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pt Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Strontium Carrier GFPC, SrOO, solid-ALL ESS 79 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

QUALITY CONTROL DATA 77

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Reoort Date: March 13, 2007 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

181852 PQrmnn me NAM gQ--lefI Aual OC Units RPD%

REC%

Range AnIst Date Time Rad Alpha Spec Batch 615440 QC1201291464 181852006 DUP Americium-24 I Curium-242 Curium-243/244 QC 1201291466 LCS Americium-24 I Curium-242 Curium-243/244 QC 1201291463 MB Ameficium-241 u

0.0195 Uncert:

+/-0.0871 TPU:

+/-0.0872 U

0.0494 Uncert:

+/-0.111 TPU:

+/-0.112 U

-0.0434 Uncert:

+/-0.0903 TPU:

+/-0.0905 13.0 Uncert:

TPU:

Uncert:

TPU:

15.6 Uncert:

TPU:

U 0.033

+/-0.0767

+/-0.0768 U

0.00

+/-0.0711

+/-0.0711 U

-0.00845

+/-0.071

+/-0.071 11.2

+/-1.15

+/-1.88 U

0.0308

+/-0.0603

+/-0.0604 15.8

+/- 1.36

+/-2.49 U

-0.00601

+/-0.0 177

+/-0.0177 U

0.00

+/-0.0581

+/-0.05 81 U

0.00

+/-0.0577

+/-0.0577 pCi/g 51 pCi/g 200 pCi/g 135 pCi/g (0% - 100%) DXH2 03/08/07 07:56 (0% - 100%)

(0%- 100%)

86 (75%-125%)

Curium-242 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

pCi/g pCi/g pCi/g pCi/g PCi/g pCi/g pCi/g pCi/g 101 (75%-125%)

03/08/07 07:56 Curium-243/244 QC1201291465 181852006 MIS Americium-24 I Curium-242 Curium-243/244 13.6 u

0.0195 Uncert:

+/-0.0871 TPU:

+/-0.0872 U

0.0494 Uncert:

+/-0.111 TPU:

+/-0.112 16.3 U

-0.0434 Uncert:

+/-0.0903 TPU:

+/-0.0905 U

12.4

+/-1.22

+/-2.04 0.00

+/-0.0628

+/-0.0628 15.3

+/-1.35

+/-2.42 91 (75%-125%)

03/08/07 07:56 94 (75%-125%)

Batch 615441 QC1201291468 181852006 DUP Plutonium-238 U

-0.0703 U

-0.0204 pCi/g 110 (0% -100%) DXH2 03/08/07 07:56 78

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Page 2 of 9 Parmname Rad Alpha Spec Batch NOM Sample Qual QC Units RPD%

REC%

Ranae Anist Date Time 615441 Plutonium-239/240 QC 1201291470 LCS Plutonium-238 Plutonium-239/240 QC 1201291467 MB Plutonium-238 Plutonium-239/240 QC1201291469 181852006 MIS Plutonium-238 Plutonium-239/240 Uncert:

+/-0,0784 TPU:

+/-0.0788 u

0.0453 Uncert:

+/-0.0849 TPU:

+/-0.085 Uncert:

TPU:

13.0 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0703 Uncert:

+/-0.0784 TPU:

+/-0.0788 13.5 U

0.0453 Uncert:

+/-0.0849 TPU:

+/-0.085 u

1.73 Uncert:

+/-7.14 TPU:

+/-7.14

+/-0.0698

+/-0.0698 U

0.0601

+/-0.0833

+/-0.0835 U

-0.0131

+/-0.0564

+1-0.0564 13.0

+/-1.17

+/-1.73 U

0.0159

+/-0.0633

+/-0.0634 U

0.0233

+/-0.0617

+/-0.0617 pCilg 28 pCi/g pCilg (0% - 100%)

(75%- 125%)

100 (75%-125%)

pCilg pCi/g pCilg pCilg U

0.0262

+/-0.0971

+/-0.0971 14.8

+/-1.36

+/-2.05 (75%-1 25%)

110 (75%-125%)

Batch 615442 QC1201291472 181852006 DUP Plutonium-24 I U

-2.52

+/-5.43

+/-5.43 pCilg 0

(0% - 100%) DXH2 03/09/07 10:37 QC1201291474 LCS Plutonium-241 QC 1201291471 MB Plutonium-24 I 139 Uncert:

TPU:

Uncert:

TPU:

141

+/- 13.3

+/-19.6 U

1.10

+/-6.34

+/-6.34 pCilg pCilg pCi/g 101 (75%-125%)

03/10/07 23:29 03/10/07 23:13 03/09/07 10:53 QC1201291473 181852006 MS Plutonium-24 I Rad Gamma Spec Batch 615799 QC1201292387 181852001 DUP Actinium-228 141 U

1.73 Uncert:

+/-7.14 TPU:

+/-7.14 132

+/-12.4

+/-18.1 93 (75%-125%)

0.488

+/-0.206 Uncert:

0.615

+/-0.102

+/-0,102 pCi/g 23 (0% -100%)

MJHI 03/08/07 19:38 79

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Parmname Rad Gamma Spec Batch 615799 Page 3 of 9 REC %

Range Anlst Date Time NOM Sample Qual 0C Units RPD%

Americium-24 I Bismuth-2 12 Bismuth-2 14 Cesium-I 34 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.206 u

-0.00779 Uncert:

+/-0.0369 TPU:

+/-0.0369 0.6 16 Uncert:

+/-0.326 TPU:

+/-0.326 0.439 Uncert:

+/-0.126 TPU:

+/-0.126 u

0.0359 Uncert:

+/-0.0343 TPU:

+/-0.0343 u

0.00382 Uncert:

+/-0.0273 TPU:

+/-0.0273 u

-0.0116 Uncert:

+/-0.0304 TPU:

+/-0.0304 u

-0.0279 Uncert:

+/-0.0866 TPU:

+/-0.0866 u

0.0436 Uncert:

+/-0.0923 TPU:

+/-0.0923 u

-0.0145 Uncert:

+/-0.05 19 TPU:

+/-0.05 19 0.546 Uncert:

+/-0.0722 TPU:

+/-0.0722 0.571 Uncert:

+/-0.108 TPU:

+/-0.108 u

0.00465 Uncert:

+/-0.0266 TPU:

+/-0.0266 u

-0.00203 Uncert:

+/-0.0281 TPU:

+/-0.0281I 9.47 Uncert:

+/-0.935 TPU:

+/-0.935 0.439 Uncert:

+/-0.126 TPU:

+/-0.126 u

0.000965 Uncert:

+/-0.0207 U

0.036

+/-0.037 5

+/-0.0375 0.365

+/-0.174

+/-0.174 0.442

+/-0.0627

+/-0.0627 U 1 0.00

+/-0.0171

+/-0.0171 U

0.0185

+/-0.0148

+/-0.0148 U

-0.00783

+/-0.0146

+/-0.0146 U

-0.000612

+/-0.0365

+/-0.0365 U

-0.00753

+/-0.0371

+/-0.0371 U

-0.00224

+/-0.0333

+/-0.0333 0.559

+/-0.0563

+/-0.0563 0.580

+/-0.0694

+/-0.0694 U

0.00592

+/-0.0128

+/-0.0128 U

0.000299

+/-0.0119

+/-0.0119 10.2

+/-0.799

+/-0.799 0.442

+/-0.0627

+/-0.0627 U

-0.00882

+/-0.0145 pCilg 311 pCilg 51 pCi/g 1

pCi/g 13 pCilg 132 pCi/g 39 pCilg 191 pCi/g 284 pCilg 146 pCi/g 2

pCilg 2

pCi/g 24 pCilg 269 pCi/g 8

pCi/g 1

pCilg 249 (0% -100%)

(0% -100%)

(0% -100%)

(0% -100%)

(0%- 100%)

(0% - 100%)

(0% -100%)

(0% - 100%)

(0% - 100%)

(0% -20%)

(0% -20%)

(0% - 100%)

(0%- 100%)

(0% -20%)

(0%- 100%)

(0%- 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 80

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

181852 Parmname Rad Gamma Spec Batch 615799 Thallium-208 QC1201292388 LCS Actinium-228 Americium-24 1 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample OuaI 0C Page 4 of 9 REC%

Rang-e AnIst Date Time NOM Units RPD%

TPU:

Uncert:

TPU:

Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.46 Uncert:

TPU:

13.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0207 0.208

+/-0.0555

+/-0.0555

+/-0.0145 0.177

+/-0.030 1

+/-0.0301 U

-0.49

+/-0.420

+1-0.420 28.0

+/-3.18

+/-3.18 U

-0.0647

+/-0.711

+/-0.711 U

-0.124

+/-0. 161

+/-0.161 U

0.00765

+/-0.105

+/-0.105 10.3

+/-0.958

+/-0.958 15.0

+/-0.949

+/-0.949 U

0.0356

+/-0.2 17

+/-0.217 U

-0.0918

+/-0.237

+/-0.237 U

-0.092

+/-0.254

+/-0.254 U

0.0841

+/-0.140

+/-0. 140 U

0.0818

+/-0.214

+/-0.2 14 U

-0.0307

+/-0.0978

+/-0.0978 U

-0.063

+/-0.0849

+/-0.0849 U

0.326 pCi/g 16 (0% -100%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g PGi/g 03/08/07 12:51 120 (75%-125%)

109 (75%-125%)

111 (75%-125%)

A I

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com QC Summary Workorder:

181852 Page 5 of' 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 615799 Radium-226 Silver-108m Thallium-208 QC1201292386 Actinium-228 Americium-24 1 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U ncert:

TPU:

+/-0.686

+/-0.686 U

-0.124

+/-0.161

+1-0.161 U

0.0625

+/-0.0843

+/-0.0843 U

-0.0547

+/-0.0899

+/-0.0899 U

0.037

+/-0.0302

+/-0.0302 U

0.001 19

+/-0.024

+/-0.024 U

-0.0276

+/-0.049

+/-0.049 U

0.0108

+/-0.0287

+/-0.0287 U

-0.000536

+/-0.00806

+/-0.00806 U

-0.00353

+/-0.00649

+/-0.00649 UT 0.00

+/-0.0227

+/-0.0227 U

-0.00489

+1-0.0193

+/-0.0193 U

0.0131

+/-0.0188

+/-0.0188 U

-0.0222

+/-0.0233

+/-0.0233 U

0.0065

+/-0.0168

+/-0.0168 U

0.000597

+/-0.0172

+/-0.0 172 pCilg pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pci/g 03/08/07 19:37 (75%-1 25%)

Cobalt-60 Europium-I 52 Europium-154 Europium-155 Lead-212 Lead-214 R2

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Parmname Rad Gamma Spec Batch 615799 Page 6 of 9 REC%

Range Anist NOM Sample Qua]

OC Units RPD%

Date Time Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I 08m Thallium-208 Rad Gas Flow Batch Uncert:

TMU Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.00255

+/-0.00629

+/-0.00629 U

0.00489

+/-0.00664

+/-0.00664 U

0.0428

+/-0.144

+1-0.144 U

0.0108

+/-0.0287

+/-0.0287 U

-0.000251

+/-0.00615

+/-0.00615 U

-0.00743

+/-0.0095

+/-0.0095 pCi/g pCi/g pCilg pCi/g pCilg pCilg 615740 QC1201292196 181852006 DUP Strontium-90 QC1201292198 LCS Strontium-90 QC120l292195 MB Strontium-90 QC1201292197 181852006 MS Strontium-90 Rad Liquid Scintillation Batch 615544 QC1201291713 181852006 DUP Iron-55 u

-0.00512 Uncert:

+/-0.0167 TPU:

+/-0.0167 U

0.0264

+/-0.0221

+/-0.0221 1.52

+/-0.106

+1-0.115 pCi/g 0

(0% - 100%) KSDI 1.52 Uncert:

TPU:

Uncert:

TPU:

5.09 U

U ncert:

TPU:

U

-0.0101

+/-0.0201

+/-0.0201 pCi/g pCi/g pCi/g 100 (75%-125%)

03/12/07 15:31 03/12/07 15:32 03/12/07 15:3]

03/12/07 15:31

-0.005 12

+/-0.0167

+/-0.0167 5.33

+/-0.379

+/-0.4 12 105 (75%-125%)

U

-12 Uncert:

+/-44.1 TPU:

+/-44.1 U

10.8

+/-46.7

+/-46.7 pCi/g pCi/g n

(0% - 100%) VIXPI QC 1201291715 LCS Iron-55 QC 1201291712 MB Iron-55 1240 Uncert:

TPU:

1190

+/-89.9

+/-1 16 96 (75%-125%)

03/10/07 20:04 03/10/07 20:36 03/10/07 19:47 U

2.24 pCi/g 83

GEL LABORATORIES LLC 2046 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Page 7 of 9 Parmname NOM Sample Qua]

QC Units RPD%

REC %

Range Anist Date Time Rad Liquid Scintillation Batch 615544 Uncert:

TPU:

QC1201291714 181852006 MS Iron-55 1270 U

Uncert:

TPU:

+/-49.8

+/-49.8 1110

+/-84.7

+/-109

-12

+/-44.1

+/-44.1 pCilg 87 (75%-125%)

03/10/07 20:20 Batch 615546 QC1201291717 181852006 DUP Nickel-63 QC 1201291719 LCS Nickel-63 QC 1201291716 M B Nickel-63 QC1201291718 181852006 MIS Nickel-63 U

-11.2 Uncert:

+/-10.9 TPU:

+/-10.9 U

-7.67

+/-8.87

+/-8.87 pCilg 0

(0% - 100%) VIXPI 573 Uncert:

TPU:

Uncert:

TPU:

587 U

Uncert:

TPU:

484

+/-15.4

+/-23.4 U

-2.81

+/-11.0

+/-11.0 pC~ig pCi/g 85 (75%-125%)

03/10/07 23:18 03/11/07 00:21 03/12/07 18:20 03/10/07 23:49

-11.2

+/-10.9

+/-10.9 Batch 615548 QC1201291722 181852006 DUP Technetium-99 QC1201291724 LCS Technetium-99 QC1201291721 MB Technetium-99 QC1201291723 181852006 MS Technetium-99 Batch 615550 QC1201291726 181852006 DUP Tintium U

-0.0998 Uncert:

+/-0.210 TPU:

+/-0.210 U

510

+/-16.8

+/-25.1

-0.311

+/-0.221

+/-0.221 15.9

+/-0.478

+/-0.621 87 (75%-125%)

pCi/g 0

(0% - 100%) \\IxpI 19.5 U ncert:

TPU:

Uncert:

TPU:

19.5 U

Uncert:

TPU:

U

-0.283

+/-0.190

+/-0.190 pCi/g pCi/g pCi/g 82 (75%-125%)

03/12/07 13:32 03/12/07 14:36 03/12/07 13:00 03/12/07 14:04

-0.0998

+/-0.2 10

+/-0.2 10 U

-0.322 Uncert:

+/-1.24 TPU:

+/-1.24 U

16.1

+/-0.488

+/-0.630 0.0544

+/-1.34

+/-1.34 10.6

+/-1.64

+/-1.65 82 (75%-125%)

pCi/g 0

(0% - 100%) '\\XD2 03/09/07 02:06 QC1201291728 LCS Tritium 11.2 Uncert:

TPU:

pCi/g 95 (75%-125%)

03/09/07 04:11 R4

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Page 8 of 9 OC Units RPD%

REC%

Ranee Anist Parmname Rad Liquid Scintillation Batch 615550 NOM Sample Qual Date Time QC1201291725 MB Tritium Uncert:

TPU:

U

-0.32 1

+/-1.24

+/-1.24 pCi/g pCilg 03/09/07 01:04 03/09/07 03:08 QC1201291727 181852006 MS Tritium Batch 615551 11.7 U

-0.322 Uncert:

+/-1.24 TPU:

+/-1.24 U

-0.0845 Uncert:

+/-0.0856 TPU:

+/-0.0856 10.4

+/-1.70

+/-1.71 88 (75%-125%)

QC1201291730 181852006 DUP Carbon-14 QC1201291732 LCS Carbon-14 QC1201291729 MB Carbon-14 QC1201291731 181852006 MS Carbon-14 U

-0.0665

+/-0.0904

+/-0.0904 6.52

+/-0.371

+/-0.385 pCi/g 0

(0% - 100%) 'kXD2 6.65 Uncert:

TPU:

Uncert:

TPU:

U

-0.0464

+/-0.0865

+/-0.0865 pCi/g pCi/g pCi/g 98 (75%-125%)

03/09/07 0 1:59 03/09/07 04:02 03/09/07 00:58 03/09/07 03:01 7.22 U

-0.0845 Uncert:

+/-0.0856 TPU:

+/-0.0856 7.32

+/-0.213

+/-0.242 101 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy~-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

181852 Page 9 of 9 Parmname NOM Sample Quall QC Units RPD%

REC%

Range Anlst Date Time y

A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is'a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

86

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 182417 SDG: MSR#07-00114 March 21, 2007 Laborator:y Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on March 16, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 182417001 9312-0005-0201 182417002 9312-0005-0211 182417003 9312-0005-0221 182417004 9312-0005-0231 Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Four soil samples were analyzed for Gamma, Strontium-90 and Tc-99.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Ch~erl ones Project Manager GEL Laboratories LLc GELLabratrie uc PO Box 30712 Charleson, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.755.1178 2

www.gal.com

List of current GEL Certifications as of 21 March 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas F88-065 1

CLIA 42DO904046 California 01 151CA Colorado GenEngLabs Connecticut PH-01 69 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87 156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO1 2 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87 156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia Washington 00151 C 1641 3

Chain of Custody and Supporting Documentation 4

Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-,00078 362 Injun Hollow Road, East Hampton, CT 06424 860-267 -25 56 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Coe.

o 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)

Priority: []30D.Lil ISD.Z7D.

Other:

-7_________J 2~

Sample Designation Date Time Comment, Preservation Lab Sample ID 93 12-0005-0201 3/14/07 1252 TS G

BP X

9312-0005-0211

.3/14/07 1254 TS G

BP X________

93 12-0005-0221 3/14/07 1255 TS G

BP X

9312-0005-0231 3/14/07 1256 TS G

BP X_______________________

NOTES: P0OH 002332 MSR #:07-001 14 Z LTP QA D Radwaste QA DNon QA Samples Shipped Via:

Internal Container Z Fed Ex Temp.: IJOt Deg. C El UPS F] Hand Ciustody Sealed?

1) Relinquis)u.'

Date/Time

2) Received By Date/Time Custody Seal Intact?

o~/-

E,0 l Other

3) Relinquished dy Date/Time
4) Received By Date/Time N 11N Bill of Lading #
5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytcal Lab Services

  • CY-fSC-SOW-O0i Figure 1. Sample Check-'in List.

Date/Time Received:,S I'~9(

SDG#:

A ksf-40-5c/

Work Order Number:

11 141.7 T

ShppngCdtane I 9~3 0 7 Vb ) 3C(RChain of Custody #.

  • 1.

Custody Seals oiishipping container intact?.

2.

Custody Seals dated and signed?

  • 3.

Chain-of-Custodiy record present?

.4.

Cooler temperature C

  • 5.,

Vermiculite/packing materials -is:

6.

Number of samples in shipping container:

7.

Sample holding times exceeded?

9fl-COO-7 Yes VNoJ Yes'(,)41o [

YesU'NO[

Wet []Dry E-Yes (INo U 8.Samples have.

tape____hazard labels

  • _____custody seals appropriate sample labels
9. Samples are.

.UZinigood condition

-__leaking

-broken

-have air bubbles

10.

Were any anomnalies identified in sample receipt?

Yes [

o. Ioq[*<
11.

D escription of anomalies, (include sample numbers):

Date:

3-1(~Q-07 Sample. Custodian/Laboratory:

Telephoned to:

.on By.

6

SAMPLE RECEIPT & REVIEW FORM PM use wily 4C.lient:

2CcM et_+iCi

)1t 11 jeSDG/ARCOCIWork Order:

I 17-2 j / -7 Date Reeived-.I-:(-

P(A)_________rnonI R

eceived By1:TSI______________

Sample Receipt Criteria Comments/Qualiflers (Required for Non-Conforming Items)

Sipncotiesreceived Circle Aoplicable: seals broken damaged container leaking container oither (describe) 1intact and sealed?____________________________________

Samples requiring cold Circle Coolant #

ice bags blue ice dry ice none ntederi 2 preservation. within (4 +/-'2 C)?

/ 0 0 Record preservation method.

_______________d_____________

3Chain of custody documents included with shipment?

SSample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) isealed?_____________________________

5 Samples requiring chemical Sample ID's. containers affected and observed pH:

-preservation at proper pH?

6 VOA vials free of headspace Sample !D~s and containers affected:

-(defined as < 6mm bubble)?__________________________

Are Encore containers present?

7 (If yes, immediately deliver to

__VOA laboratory) 8 Samples received within holding I' n et fetd time?

9SmlIDson COC match ID's Sample ID's and containers affected:

__on bottles?_____________________________

10 Date & time on COC match date Sample ID's affected:

__& time on bottles?

11Number of containers received Sample ID's affected:

match number indicated on COC?

12COG form is properly signed in 12relinquished/received sections?_____________________________

14 Ai ilTacig#s

-7 3O07?L/O0 13 O' l

V a

RSO RAD Receipt #____

~

'~

,~*If

> x2 area background is observed on samples identified as "non-Suspected Hazard Information 0

4A

  • 'regulated/non-radioactive", contact the Radiation Safety group for further I

investigation.

A Radiological Classification?

tZMaximum Counts Observed*:

1B PCB Regulated?

Shipped as DO'[ Hazardous C Material? If yes, contact Waste VHazard Class Shipped:

manager or ESH Manager.

UN#:

DPR Reguated as a Foreign Soil'!

PM (or PMA) review of Hazard classification:

Initials Date:

4 7

Subject:

COC-07-0078 From: "Rick E. Gault" <Gault@CYAPCO.com>

Date: Thu, 15 Mar 2007 09:03:05 -0400 To: "Cheryl Jones" <cj ~gel.com>

Cheryl; We're sending 4 samples (under MSR 07-00114) to GEL today. All of the samples have a 7 day TAT request. It is acceptable for GEL to use the traced/untraced Tc-99 process for these quick TAT requests. See attached COG for requested analyses.

Rick Gault CYAPCO 860-267-3903 Content-Description: SCAN8082_000.pdf SCAN8082000O.pdf Content-Type:

application/octet-stream:

Content-Encoding:

base64 a

Data Review Qualifier Definitions 9

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensat ion product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL <sample value <PQL ED Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is >10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UT Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories LLC PO Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.755.1178 1L0 www.gel~com

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 182417 Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 182417001 182417002 182417003 182417004 1201298461 1201298462 1201298463 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 618297 617707 Client ID 9312-0005-0201 9312-0005-0211 9312-0005-0221 9312-0005-0231 Method Blank (MB) 182417001(9312-0005-0201) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

IL2

Designated QC The following sample was used for QC: 182417001 (9312-0005-0201).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

.Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The duplicate and sample, 1201298462 (9312-0005-0201) and 182417001 (9312-0005-0201), did not meet the relative percent difference requirement for Pb-2 14, however, they do meet the relative error ratio requirement with a value of 2.19127.

Qualifier information Qualifier Reason Analyte Sample U'

U' Data rejected due to high peak width.

Data rejected due to low abundance.

Radium-226 Bismuth-214 Cesium-134 1201298461 1201298461 182417002 182417003 182417004 1201298462 1201298461 1201298461 Lead-214 U'

Data rejected due to no valid peak.

Potassium-40 13

Method/Analysis Information Product:

GFPC, 5r90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 617750 617709 617707 Sample ID 182417001 182417002 182417003 182417004 1201297139 1201297140 1201297141 1201297142 Client ID 9312-0005-0201 9312-0005-0211 9312-0005-0221 9312-0005-0231 Method Blank (MB) 182417002(9312-0005-0211) Sample Duplicate (DUP) 182417002(9312-0005-0211) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC 14

The following sample was used for QC: 182417002 (9312-0005-0211).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:

617711 1-5

Sample ID 182417001 182417002 182417003 182417004 1201297029 1201297030 1201297031 1201297032 Client ID 9312-0005-0201 9312-0005-0211 9312-0005-0221 9312-0005-0231 Method Blank (MB) 182417001(9312-0005-0201) Sample Duplicate (DUP) 182417001 (9312-0005-0201) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 182417001 (93 12-0005-0201).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

4 NJA

'A-N 1-7

SAMPLE DATA

SUMMARY

IS

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOlI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-OO1 14 GEL Work Order: 182417 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 19

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

93 12-0005-0201 Project:

YANK01204 Sample ID:

182417001 Client ID:

YANKO0l Matrix:

TS Vol. Recv.:

Collect Date:

14-MAR-07 Receive Date:

16-MAR-07 Collector:

Client Moisture:

10.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pi Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.609

+/-0.165 0.0791

+/-0.165 0.158 pCi/g MJHI 03/19/07 1504 618297 Americium-241 U

0.0477

+/-0.0331 0.0288 +/-0.0331 0.0577 pCi/g Bismuth-212 0.548

+/-0.272 0.144

+/-0.272 0.287 pCilg Bismuth-214 0.497

+/-0.112 0.0365

+/-0.112 0.073 pCi/g Cesium-134 U

0.0414

+/-0.0294 0.0287 +/-0.0294 0.0573 pCilg Cesium-137 U

0.00748

+/-0.0254 0.0232 +1-0.0254 0.0463 pCilg Cobalt-60 U

0.0125

+/-0.0338 0.0261 +/-0.0338 0.0521 pCi/g Europium-152 U

-0.0296

+/-0.070 0.0489

+/-0.070 0.0977 pCilg Europium-154 U

-0.0382

+/-0.0897 0.0716 +/-0.0897 0.143 pCi/g Europium-ISS U

-0.0515

+/-0.0605 0.0453 +/-0.0605 0.0905 pCi/g Lead-212 0.480

+/-0.0669 0.0256 +/-0.0669 0.0511 pCilg Lead-214 0.410

+/-0.0893 0.0367 +/-0.0893 0.0734 pCi/g Manganese-54 U -0.00173

+/-0.0249 0.0216 +/-0.0249 0.0432 pCi/g Niobium-94 U -0.00355

+/-0.0232 0.0203 +/-0.0232 0.0406 pCi/g Potassium-40 9.50

+/-1.02 0.229

+/-1.02 0.457 pCi/g Radium-226 0.497

+/-0.112 0.0365

+/-0.112 0.073 pCilg Silver-108rn U

0.00407

+/-0.0191 0.0171 +/-0.0191 0.0342 pCi/g Thallium-208 0.206

+1-0.0441 0.0187 +/-0.0441 0.0373 pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U

0.0139

+/-0.0205 0.0153 +/-0.0205 0.0355 pCi/g KSDI 03/20/07 1329 617750 Rad Liquid Scintillation Analysis Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.323

+/-0.258 0.2 10

+/-0.258 0.430 pCi/g MXPI 03/20/07 2322 617711 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 03/16/07 1117 617707 The following Analytical Methods were performed Method Description 20

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

Sample ID:

9312-0005-0201 182417001 Project:

Client ID:

Vol. Recv.:

YANK01204 YANKO0l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Di 1

EML HASL 300,4.5.2.3 2

EPA 905.0 Modified 3

DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS Liquid Scint Tc99, Solid-ALL FS 87 84 (25%-I125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

21

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wvww.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-0211 182417002 TS 14-MAR-07 16-MAR-07 Client 10.1%

Project:

Client ID:

Vol. Recv.:

YANK01 204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch D~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM &ALL FSS 226 In growth Waived Actinium-228 0.452

+/-0.142 0.0547

+/-0.142 0.109 pCi/g MIH1 03/19/07 1505 618297 Americium-241 U

0.0916

+/-0.112 0.0982

+/-0.112 0.196 pCi/g Bismuth-212 0.488

+/-0.241 0.113

+/-0.241 0.226 pCi/g Bismuth-214 0.457

+/-0.0903 0.030 +/-0.0903 0.0599 pCi/g Cesium-134 VI 0.00

+1-0.0284 0.0187 +1-0.0284 0.0374 pCi/g Cesium-137 U

0.0145

+/-0.0188 0.0174 +/-0.0188 0.0347 pCi/g Cobalt-60 U

0.00483

+/-0.0197 0.0171 +/-0.0197 0.0343 pCi/g Europium-152 U

-0.0115

+/-0.0456 0.0394 +/-0.0456 0.0787 pCi/g Europium-154 U-0.000341

+/-0.0563 0.0477 +/-0.0563 0.0954 pCi/g Europium-155 U

0.0602

+/-0.0785 0.0494 +/-0.0785 0.0988 pCi/g Lead-21 2 0.526

+/-0.0753 0.024 +/-0.0753 0.0479 pCi/g Lead-214 0.422

+/-0.0806 0.0296 +/-0.0806 0.0592 pCi/g Manganese-54 U -0.00509

+/-0.0187 0.0155 +/-0.0187 0.031 pCi/g Niobium-94 U

-0.0121

+/-0.0169 0.0137 +/-0.0169 0.0274 pCi/g Potassium-40 9.19

+/-0.987 0.128

+/-0.987 0.256 pCi/g Radium-226 0.457

+/-0.0903 0.030 +/-0.0903 0.0599 pCi/g Silver-108m U -0.00685

+/-0.0151 0.0133 +/-0.0151 0.0266 pCi/g Thallium-208 0.171

+/-0.0421 0.0131

+/-0.0421 0.0261 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U

0.00937

+/-0.0224 0.0176 +/-0.0224 0.0405 pCi/g KSDI 03/20/07 1329 617750 Rad Liquid Scintillation Analysis Liquid Scint Tc99, So/id-ALL FSS Technetium-99 U

0.266

+/-0.259 0.2 12

+/-0.259 0.433 pCi/g MXPI 03/20/07 2353 617711 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-02l LXM2 03/16/07 1117 617707 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 22

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack Mc~arthy Project:

Soils PO# 002332 Report Date: March 21, 2007 Client Sample ID:

Sample ID:

93 12-0005-0211 182417002 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Dt 2

EPA 905.0 Modified 3

DOE EML HASL-.300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS Liquid Scint Tc99, Solid-ALL FS 77 86 (25%-1 25%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

23

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-0221 182417003 TS 14-MAR-07 16-MAR-07 Client 10.2%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch P~

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.383

+/-0.138 0.0608

+/-0.138 0.121 pCi/g MJHI 03/19/07 1505 618297 Americium-241 U

0.0336

+/-0.0844 0.0743 +/-0.0844 0.149 pCi/g Bismuth-212 0.405

+/-0.183 0.114

+/-0.183 0.227 pCi/g Bismuth-214 0.412

+/-0.0889 0.0326 +/-0.0889 0.0652 pCilg Cesium-] 34 UI 0.00

+/-0.029 0.0205

+/-0.029 0.0409 pCi/g Cesium-] 37 U

0.0191

+/-0.0194 0.0145 +/-0.0194 0.029 pCi/g Cobalt-60 U

0.0028

+/-0.0235 0.0196 +/-0.0235 0.0392 pCi/g Europium-152 U

-0.0142

+1-0.052 0.042

+/-0.052 0.084 pCi/g Europium-154 U

0.0432

+/-0.0606 0.0561 +/-0.0606 0.112 pCi/g Europium-.155 U

0.0665

+/-0.061 0.0485

+/-0.061 0.0969 pCi/g Lead-2 12 0.518

+/-0.0645 0.025 +/-0.0645 0.0499 pCi/g Lead-214 0.414

+/-0.0892 0.0327 +/-0.0892 0.0653 pCi/g Manganese-54 U -0.00801

+/-0.0196 0.0162 +/-0.0196 0.0325 pCi/g Niobium-94 U

0.00376

+/-0.018 0.016

+/-0.018 0.0321 pCilg Potassium-40 8.96

+/-0.965 0.154

+1--0.965 0.308 pCilg Radium-226 0.412

+/-0.0889 0.0326 +/-0.0889 0.0652 pCi/g Silver-108m U

-0.0133

+/-0.0177 0.0146 +/-0.0177 0.0291 pCifg Thallium-208 0.153

+/-0.0384 0.0146 +/-0.0384 0.0292 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strontium-90 U

0.00161

+/-0.0191 0.0158 +/-0.0191 0.0364 pCi/g KSDI 03/20/07 1329 617750 Rad Liquid Scintillation Analysis Liquid Scini Tc99, Solid-ALL FSS Technetium-99 U

0.289

+/-0.239 0.195

+/-0.239 0.399 pCi/g MXPI 03/21/07 0025 617711 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 03/16/07 1117 617707 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 24

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

Sample ID:

9312-0005-0221 182417003 Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Di 2

EPA 905.0 Modified 3

DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier Technetium-99m Tracer GFPC, Sr90, solid-ALL FSS Liquid Scint Tc99, Solid-ALL FS 86 86 (25%-1 25%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD1 Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using ÷f-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

25

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address;:

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date:

March 21, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9312-0005-0231 182417004 TS 14-MAR-07 16-MAR-07 Client 10.5%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Pt Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.517

+/-0.141 0.0542

+/-0.141 0.108 pCi/g MIHI 03/19/07 1506 618297 Americium-241 U

-0.0183

+/-0.0552 0.0461

+/-0.0552 0.0921 pCi/g Bismuth-212 U

0.171

+/-0.243 0.110

+/-0.243 0.219 pCi/g Bismuth-214 0.418

+/-0.0778 0.0269 +/-0.0778 0.0538 pCi/g Cesium-I 34 UI 0.00

+/-0.0311 0.0184 +/-0.0311 0.0367 pCi/g Cesium-137 U

0.019

+/-0.026 0.016

+/-0.026 0.0319 pCi/g Cobalt-60 U

0.0143

+/-0.0158 0.0149 +/-0.0158 0.0297 pCi/g Europium-152 U

0.0322

+/-0.0466 0.0417 +/-0.0466 0.0834 pCi/g Europium-154 U

0.0172

+/-0.0565 0.0494 +/-0.0565 0.0987 pCi/g Europium-ISS U

0.0589

+/-0.0559 0.0391

+/-0.0559 0.0781 pCi/g Lead-212 0.456

+/-0.0549 0.0226 +/-0.0549 0.0451 pCi/g Lead-214 0.404

+/-0.0734 0.0287 +/-0.0734 0.0573 pCi/g Manganese-54 U

0.0114

+/-0.0156 0.0146 +/-0.0156 0.0292 pCi/g Niobium-94 U -0.00854

+/-0.0164 0.0135 +/-0.0164 0.0269 pCi/g Potassium-40 9.96

+/-0.889 0.104

+/-0.889 0.208 pCi/g Radium-226 0.418

+/-0.0778 0.0269 +/-0.0778 0.0538 pCi/g Silver-108m U -0.00444

+/-0.0143 0.0125 +/-0.0143 0.025 pCi/g Thallium-208 0.159

+/-0.0368 0.0132 +/-0.0368 0.0263 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90 U-0.000607

+/-0.0191 0.0161

+/-0.0191 0.0369 pCi/g KSDI 03/20/07 1330 617750 Rad Liquid Scintillation Analysis Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.195

+/-0.240 0.198

+/-0.240 0.404 pCi/g MXPI 03/21/07 0057 617711I The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 03/16/07 1117 617707 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 26

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: March 21, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

93 12-0005-0231 Project:

YANK01204 Sample ID:

182417004 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Di 2

EPA 905.0 Modified 3

DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Strontium Carrier GFPC, Sr90, solid-ALL FSS 85 (25%-I125%)

Technetium-99m Tracer Liquid Scint Tc99, Solid-ALL FS 92 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by CC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

27

. I QUALITY CONTROL DATA 28

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: March 21, 2007 Page 1 of 6 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

182417 Parmname Rad Gamma Spec Batch 618297 NOM Sample Qual QC Units RPD%

REC %

Range Anist Date Time QC1201298462 Actinium-228 Americium-24 I Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 182417001 DUP 0.609 Uncert:

+/-0.165 TPU:

+/-0.165 U

0.0477 Uncert:

+/-0.0331 TPU:

+/-0.0331 0.548 Uncert:

+/-0.272 TPU:

+/-0.272 0.497 Uncert:

+/-0.112 TPU:

+/-0.112 U

0.0414 Uncert:

+/-0.0294 TPU:

+/-0.0294 u

0.00748 Uncert:

+/-0.0254 TPU:

+/-0.0254 U

0.0125 U ncert:

+/-0.0338 TPU:

+/-0.033 8 u

-0.0296 Uncert:

+/-0.070 TPU:

+/-0.070 u

-0.0382 Uncert:

+/-0.0897 TPU:

+/-0.0897 U

-0.0515 Uncert:

+/-0.0605 TPU:

+/-0.0605 0.480 Uncert:

+/-0.0669 TPU:

+/-0.0669 0.4 10 Uncert:

+/-0.0893 TPU:

+/-0.0893 U

-0.00173 Uncert:

+/-0.0249 TPU:

+/-0.0249 U

-0.00355 Uncert:

+/-0.0232 TPU:

+/-0.0232 0.570

+/-0.152

+/-0.152 U

0.0387

+/-0.102

+/-0.102 0.389

+J-0.242

+/-0.242 0.485

+/-0.0843

+/-0.0843 UT1 0.00

+/-0.0236

+/-0.0236 U

0.00785

+/-0.0187

+/-0.0187 U

0.0207

+/-0.0197

+/-0.0 197 U

0.000739

+/-0.0648

+/-0.0648 U

-0.0269

+/-0.0514

+/-0.0514 U

0.0181

+/-0.0514

+/-0.0514 0.574

+/-0.0655

+/-0.0655 0.544

+/-0.0807

+/-0.0807 U

0.00726

+/-0.0177

+/-0.0177 U

0.0126

+/-0.0174

+/-0.0174 pCi/g 7

pCi/g 21 pCi/g 34 pCi/g 2

pCi/g 48 pCi/g 5

pCi/g 50 pCi/g 210 pCi/g 35 pCi/g 417 pCi/g 18 pCi/g 28*

pCi/g 326 pCi/g 357 (0% - 100%) MJHI1 03/19/07 15:07 (0% -100%)

(0% -100%)

(0%- 100%)

(0% - 100%)

(0% -100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0% -100%)

(0%-20%)

(0%-20%)

(0% -100%)

(0% -100%)

29

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

182417 Page 2 of 6 Parmname Rad Gamma Spec Batch 618297 NOM Sample Qual OC Units RPD%

REC%

Rani~e AnIst Date Time Potassium-40 Radium-226 Silver-I08m Thallium-208 QC 1201 298463 Actinium-228 Americium-24 I Bismuth-2 12 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 9.50 Uncert:

+/-1.02 TPU:

+/-1.02 0.497 Uncert:

+/-0.112 TPU:

+/-0.112 U

0.00407 Uncert:

+/-0.0191 TPU:

+/-0.0191 0.206 Uncert:

+/-0.0441 TPU:

+/-0.0441 LCS Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.46 Uncert:

TPU:

13.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

10.1

+/-0.922

+/-0.922 0.485

+/-0.0843

+/-0.0843 U

-0.0116

+/-0.0156

+/-0.0156 0.199

+/-0.0378

+/-0.0378 U

-0.173

+/-0.588

+/-0.588 27.7

+/-3.30

+/-3.30 U

-0.505

+/- 1.04

+/-1.04 U

-0.0815

+/-0.234

+/-0.234 U

0.0232

+/-0. 152

+1-0. 152 10.1

+/-0.897

+/-0.897 14.8

+/-1.14

+/-1.14 U

0.323

+/-0.299

+/-0.299 U

-0.0936

+/-0.282

+/-0.282 U

-0.292

+/-0.310

+/-0.3 10 U

0.059

+/-0.175

+/-0.175 U

0.0728

+/-0.221 pCi/g 6

pCi/g 2

pCi/g 416 pCi/g 3

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 03/19/07 15:07 (0% -20%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

118 (75%-125%)

107 (75%-125%)

110 (75%-125%)

Lead-212 Lead-214 Uncert:

30

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 - www.gel.com QC Summary Workorder:

182417 Page 3 of 6 Parmname Rad Gamma Spec Batch 618297 NOM SamleOa OC Units RPD%

REC%

Rne Anlqt Date Time TPU:

Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201298461 Actinium-228 Americium-241 MB Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U ncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.221 U

0.00216

+/-0.126

+/-0.126 U

-0.0138

+/-0.111

+/-0.111 U

0.307

+/-0.947

+/-0.947 U

-0.0815

+/-0.234

+/-0.234 U

-0.0206

+/-0.119

+/-0.119 U

0.0317

+/-0.117

+/-0.117 U

-0.00399

+/-0.0574

+/-0.0574 U

0.0107

+/-0.0462

+/-0.0462 U

-0.0538

+/-0.0898

+/-0.0898 UT 0.00

+/-0.0644

+/-0.0644 U

0.0171

+/-0.0142

+/-0.0142 U

-0.00319

+/-0.023

+/-0.023 U

-0.00553

+/-0.0145

+/-0.0145 U

-0.0164

+/-0.0394

+/-0.0394 U

-0.0138

+/-0.0329

+/-0.0329 U

0.0503 pCi/g pCi/g PCi/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

03/19/07 15:06 Bismuth-2 12 Bismuth-2 14 Cesium-134 Cesiuiii-137 Cobalt-60 Europium-152 Europium-154 Europium-155 331

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

182417 Parmname Rad Gamma Spec Batch 618297 Page 4 of 6 QC Units RPD%

REC%

Range Anlst Date Time NOM Sample Qual Lead-212 Lead-214 M anganese-54 Niobium-94 Potassium-40 Radium-226 Silver-lO8m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0302

+/-0.0302 U

0.0171

+/-0.0264

+/-0.0264 U1 0.00

+/-0.0731

+/-0.0731

  • U

-0.00474

+/-0.011

+/-0.011 U

-0.00525

+1-0.0122

+/-o.6122 UT 0.00

+/-0.167

+1-0.167 UI 0.00

+1-0.0644

+/-0.0644 U

0.00809

+/-0.0118

+/-0.0118 U

0.00986

+/-0.0165

+/-0.0165 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 617750 QC1201297140 182417002 DUP Strontium-90 QC1201297142 LCS Strontium-90 QC1201297139 MB Strontium-90 QC1201297141 182417002 MIS Strontium-90 Rad Liquid Scintillation Batch 617711 QC1201297030 182417001 DUP Technetium-99 U

0.00937 Uncert:

+/-0.0224 TPU:

+/-0.0224 Uj

-0.0161

+1-0.0218

+/-0.0218 1.69

+/-0.110

+/-0.121 pCi/g 0

(0% -100%)

KSDI 03/20/07 13:30 1.55 Uncert:

TPU:

Uncert:

TPU:

U

-0.000886

+/-0.0172

+/-0.0172 pCi/g pCi/g pCi/g 109 (75%-125%)

03/20/07 12:51 03/20/07 13:30 03/20/07 12:51 4.34 U

0.00937 Uncert:

+/-0.0224 TPU:

+/-0.0224 5.15

+/-0.346

+/-0.380 119 (75%-125%)

U 0.323 IU 0.182 pCi/g 0

(0% - 100%) VIXPI 03/21/07 02:00 32

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

182417 Page 5 of 6 Parmnamne NOM Samnple Qu~al QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 617711 Uncert:

+/-0.258

+/-0.243 TPU:

+/-0.258

+/-0.243 QC1201 297032 LCS Technetium-99 18.5 18.3 pCi/g 99 (75%-125%)

03/21/07 03:03 Uncert:

+/-0.474 TPU:

+/-0.658 QC1201297029 MB Technetium-99 U

0.162 pCi/g 03/21/07 01:28 Uncert:

+/-0.209 TPU:

+/-0.209 QC1201297031 182417001 MS Technetium-99 19.9 u

0.323 19.2 pCi/g 97 (75%-125%)

03/21/07 02:32 Uncert:

+/-0.258

+/-0.520 TPU:

+/-0.258

+/-0.705 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded 33

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

182417 Page 6 of 6 Parmname NOM Sample Qu~a]

QC Units RPD%

REC%

Range Anlst Date Time N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

34

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

Revision 0

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Revision 0

TANK FARM (RCA)

SURVEY UNIT 9312-0005 RELEASE RECORD Survey Unit:

Area Description Classification Survey Media Type of Survey Number of Measurements 931 2-0005 RCA / Former Tank Farm Surface Soils Final Statue Survey 15 Static, 4 Investigative STATISTICS on TOTAL POPULATION STATISTICS on NON-PARAMETRIC POPULATION Ca-i 37 DCGLOp (pCilg): 4.75E+00 Minimum Value:

-2.47E-02 Maximum Value:

2.37E+00 Mean:

1.08E-01 Median:

1.09E-02 Standard Deviation:

4.82E-01 Co-60 2.29E+00

-1.16 E-02 2.61 Ea00 1.11 E-01 2.7211-03 5.32E-01 Sr.90 9.30E-01

-1.36E-02 3.99E-02 1.076-02 8.51 E-03 1.43E-02 Tc-99 7.606.00

-2.41E6-01 1.62E-01 7.86E-01 1.436-01 3.29E+00 Ca-I 37 DCGLOp (pCilg): 4.75E+00 Minimum Value: -2.47E-02 Maximum Value: 2.376+00 Mean:

1.ý656-01 Median:

8.59E-03 Standard Deviation:

6.10E-01 Co-60 2.29E+00

-1.16E -02 2.6 1E+00 1.75E-01 2.48E-03 6.74E-01 Sr-90 9.30E6-0 1

-1.36E-02 3.99E-02 1.21E-02 1.36E-02 1.60E-02 Tc-99 7.60E+00

-2.41E6-01 1.62E*01 1.13E+ 00 8.99E-02 4.17E+00 Ca-I 37 TCo-60 TSr.90 ITc-99 Sample ID GSCodnts Resul MDA Result ]

_D eul D

esl D

o

____jIdentified

____J 20 I ____

Identified.___

2a Identified Result 2a 1_____

Identified North East IpClll lpClleI leCile)

IPCllI

/-

lcie

'a (pCi/)

IpCile)

______J Icusg) 9312-0005-001 F 2-0 0-0---------

931 2-0005-002F 931 2-0005-003F 931....

931 2-0005-004F 0 ---

931 2-0005-005F 9312-0005-006F 9312-0005-0107F 93 2-050 3F 9312-0005-0148F 9312-0005-0109F 9312----------005-1

.F 9312-0005-016-B 9312-0005-017-B 236795.06 669657.3 236795.06 669692.1 236764.94 666639.9 236764.94 668674.1 236764.94 668079.4 236764.94 668744.2 236734081 668622.3 236734ý81 666657.3 236734.81 668692.1 236734.81 669726.9 236734081 668761.6 23670ý469 683.

2367(49 687.

236704.69 668709.4 236674.56 668692.1 2367481 6976.6 236697.81 669738.8 2367 8

68696.8 2

3.82E-03 0.027 14.86E-02

-1.16E6-02 0.030 i4.79E-02 2.28E-02 0.025 4.13E-02 1,64E-01 1~0.205 1.3.46E-01 8

1.51E-031 0.016 12.73E602 1.746-02 0.016 2.966-02) 2.87602 0.026 4.18E602

+

4.116E02 0.217 3.726-01 22.65E-021 0.034 4.316E02

-1.146-02 0.029 4680)1762 02

.546027.90 016 341 1

2.38E-03 0.026 4.666-02

-3.796-03 0.032 5.246-02

-1.366-02 0.015 3.656-02 j5.846-02 0,205 I3.526-01 9

5.86E-04 [0.017 2.736-02

-1.636-03 0.017 2.776-02 4.016-03 0.024 1 4.516E02 1.04E-01 0.188 3.186-01 8

-2.47E-02 0.032 4.766-02 7b336-03 0.027 4.606-02

-5.126-03 0.017 3.536-02

-9,986-02 0.210 3.676-01 3

2.116E-02 0.013 2.226-02

+

-8.376-03 0,012 I1.946-02

-1.306-02 0.021 4.466-02 1.466-01 0.198 3.356-01 2

2.936-04 1 0.010 1.1686-02 2.306-03 0.0111 1.65602 I3.99602 0.029 4.356-02

+

1.426-01 0.210 3.556-01 8

8.596-03 I 2.3-3 00320.014 2.22E-02 230 013 2.2960 2+28602 0.028 4.806-02 9.906-02 0.203 3.466-01 9

2.026-02 10.012 2.126-02

+

9.776-03 0ý014 2.386-02 5.776-04 0.025 4.826-02 8.996-02 0.203 3.466-01 7

1.46E-02 0.026 1.946-02 2.486-03 0.013 2.166-02 2 2486-02 i0.029 4.866-02 17.596-02 0.217 3.706-01 2 5.70E-03 1 0.013 2.236-02 8.346-03 0.015 2.236-02 1.306-03 0.022 4.37E-02 6.586-03 0.196 3.376-01 I1.32E-02 0.018 1.856-02 8.766-04 0.012 1.976-02 9.936-03 0.020 3.606-02 i1.626-01 0.220 3.716-01 Fraction of DCGL 0.042 0.044 0.030

-0.008 0.017

-0.02 1 0.006 0.063 0.040 0.02 1 0.04 1 0.005 0.035 3,799

-0.010 0.049 0.038 0.019 9

0 7

2 4

2,.37E+00 0.207 12.77E-02

+

2.61 E+00 6.79E-03 0.154 12.22E-021

+

2.67E-02 0.027 14.36E-02 I

+

1.62E+01 0.050 3.78E-01 2.01 E-02 0.016 2.08E-02

+

0.012 i~2.10E-02 1,36E-02 0.026 14.58E-02 1

-2.41E-01 1.0.209 13.73E-01 t4------------------

2.42E-02 0.018 2.216E-02

+

2.14E-03 1~0.015 1~2.48E-02 2.23E-02 1'0.028 1'4.78E-021 1.43E-01 i~0.216 1 3.65E-01 I--------------------.-

~ ~ -

4----."--------"-

-4.14E-04 0.023 3.14E-02 1 9.39E-03 i~0.017 i~2.92E-02 7.64E-03 0.022

!.4.16E-02 1.93E-01 0.211 3.54E-01 1.47E-02 0.019 I2.05E-02

-1.416E-03 1'0.012 I.9-02

-2.586-0 0.023 I4.64E-02 1.43E-01 1

.1

.3.56E-01 1

REVISION 8 ae f

Page I of 2

TANK FARM (RCA)

SURVEY UNIT 9312-0005 RELEASE RECORD Attachment 4

Cs-i 37 Co-60 Sr-90 Tc-99 Sample ID GSCodnts Result 2a MVDA Idniid Result 2y MDA Idniid Result 2o MDA Idniid Result 2a MDA Ietfe North east lPts PCIISI lpCijQl IpCi/sl lpCi~ql Ie01tl (taci/al (pCg) 93200 360.5 605.3

.5-3 004 2.03E-02 3.28E-03 0.012 1.99E-02 i2.81 E-02 0.025 3.99E-02

+

1.25E-01 0.200 3.38E-01 9312-0005-019-B 236710.90 1 66061 4.93 6.180-03 0.019 2,360-02

-7.22E-03 0q018 2.85E-02 1-4.110E-03 0.026 14.92E-02 1.64E-01 0.202 13.40E-01 t -

4 9312-0005-020-I 236702.25 660712.72

--7.4-8-E--0-03-T 0.025 4.638 02 1.25E-02 00O34 9.77E-02 1.39E-02 0.021 3.55E-02 3.230-01 0.258 4q300-01 I 9312-0005-21-I 236707.91 668711.92 1.45E-02 0.019 I3.470-02 4.830 03 0.020 3.430-02 9q378-03 0.022 14.05E802 I2,66E-01 0.259 I4q330-01'

+

9312-0005-022-I 236707.00 666706.22 1.910-02 0.019 2.900-02 2.800-03 0.024 3.920-02 I1.610-03 0.019 13.648-02 I2.890-01 0,239 I3.990-01

+

9312-0005-023-1 236701.53 660707.10 1.900-02 0.026 3,190-02 1.43E-02 0.010 2.97002 1-6.07004i 0.019 3.69E-02 1.958-01 0.240 I4.048-01 Fraction of DCGL 0.049 0.015 0.064 0.050 0.045 0.035 OTHER RADIONUCLIDES Sample ID Isotope Reul 2a jD Identified DC rciono

_____________________________ _____jIat(l____

PCiqI j _____[ICeifg DCGL 9312-0005-001 F iCs-134 3.590-02 0.034 5,790-02

+

2.80+00 0.013 9312-0005-003F Me-54 4.740 02 0.033 5.50E02 1,00+01 0.005 9312-0005-005F INb-94 2.208-02 0.015 2.818E02

+

4.38+00 0.005 9312-0005-006F l~-3 882 0.033 54822.80+00 0.014 4--

!9312-0005-007F

'Am 241 8.080-02 10.072 1.210-01

+

1.681+01 0.005 19312-0005-007F

  • Mn-54 I1.528-02 i0.015 2.350-02

+

1.00+01 0.001 19312-0005-008F IMn-54 1.338-02 1i0.011 1,610-02

+

1.00+01 0.001 19312-0005-01OF iCs-134 2 2600-02 0017 i 2.73E802 I

+

2.88+00 0.009

[9312-0005-016-B j~-3 182 0.020 3.388-02

+

2.28E+00 0,008 E9312-0005-017-B3 IAm-241 12.298-02 0.018

'3.018E02

+

1.60+01 0.001 I-------------

Ea-0055-01323802 0.032 4.868-02

+

2.4E+02 0.000

~9312-0005-019-B 4C-134 f2.368-02 0.016 13.068-0 28+0 00 19312-0005-019-B jMn-54 2.14E-02 10.015 2.818E02

+

108E+01 0.002 REVISION 0Pae2o2 Page 2 of 2

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

Revision 0

QUANTILE PLOT FOR CESIUM-i137 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm Mean: 1.65E-01 pCi/g Quantile Plot For Cs-I 37 2.50E+00 2.OOE+00

.)1.50E+00 0

  • .~.OOE+00 1-11!:

I

-E N--f-N--E-~--N--U-

-u--u--s--

~

- - ~ ~

-5.OOE-Ol 0

20 40 60 80 100 Percentage Cs-I 37 Rank Percentage

-2.47E-02

-5.70E-03 2.93E-04 5.86E-04 1.5 1 E-03 2.38E-03 3.82E-03 8.59E-03 1.32E-02 1.46E-02 2.0 1IE-02 2.02E-02 2.11 E-02 2.65E-02 2.37E+00 1

2 3

.4 5

6 7

8 9

10 11 12 13 14 15 3.3%

10.0%

16.7%

23.3%

30.0%

36.7%

43.3%

50.0%

56.7%

63.3%

70.0%

76.7%

83.3%

90.0%

96.7%

3 1 -710-7 Reviewed by/Date

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm M~ean: 1.65E-01 pCi/g Frequency Plot For Cs-I 37 U

a, a)

L.

LL 16 14 12 10 8

6 4

2 0

3.74E-01 3.74-017.74E-01 1.17E+00 1.57E+00 1.97E+00 2.37E+00 Upper End Value (pCilg)

Upper End Observation Observation Value Frequency Frequency 3.74E-0 1 14 93%

7.74E-01 0

0%

1. 17E+00 0

0%

1.57E+00 0

0%

1.97E+00 0

0%

2.37E+00 1

7%

Total:

15 100%

Su mitted b Date 1 of 1

QUANTILE PLOT FOR COBALT-60 Survey Unit: 9312-0005 Survey Unit Name: RCA / Former Tank Farm Mean: 1.75E-01 pCi/g Quantile Plot For Co-60 3.OOE+00 -------------------

2.50E+00-------------------

  • ~2.00E+00-------------------

.2 S1.50E+00 -------------------

O.O1. E+00

-5.OOE-01 0

20 40 60 80 100 Percentage Co-60 Rank Percentage

-1..16E-02

-1. 14E-02

-8.37E-03

-3.79E-03

-1.63E-03

8. 76E-04 2.30E-03 2.48E-03 2.63 E-03 6.79E-03 7.33E-03 8.34E-03 9.77E-03 1.74E-02 2.61 E+00 1

2 3

.4 5

6 7

8 9

10 11 12 13 14 15 3.3%

10.0%

16.7%

23.3%

30.0%

36.7%

43.3%

50.0%

56.7%

63.3%

70.0%

76.7%

83.3%

90.0%

96.7%

I

/

I q-, I SubrW'tt 3dby/ ate Reviewed by/Dalfe

FREQUENCY PLOT FOR COBALT-60 Survey Unit: 9312-0005 Survey Unit Name: RCA / Former Tank Farm Mean: 1.75E-01 pCi/g Frequency Plot For Co-60 16 14 192 S10--

26 LL 4

2 0-4.25E-01 8.62E-01 1.30E+00 1.74E+00 2.17E+00 2.61E+00 Upper End Value (pC i/g)

Upper End Observation Observation Value Frequency Frequency 4.25E-01 14 93%

8.62E-0l1 0

0%

1.30E+00 0

0%

1.74E+00 0

0%

2.17E+00 0

0%

2.6 1E+00 1

7%

Total:

15 100%

S mtted by/Date Reviewed by/Date 1 of 1

QUANTILE PLOT FOR STRONTIUM-90 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm Mean: 1.2 1E-02 pCi/g Quantile Plot For Sr-90 5.OOEjO2 IZ-I K c

3.00E-02

.2

-1.00E-02 IId

-1.00E-02 0

20 40 60 80 100 Percentage Sr-90 Rank Percentage

-1.36E-02

-1.30E-02

-5.1 2E-03 5.77E-04 1.30E-03 4.01 E-03 9.93 E-03 1.36E-02 1.87E-02 2.28E-02 2.28E-02 2.48E-02 2.67E-02 2.87E-02 3.99E-02 1

2 3

.4 5

6 7

8 9

10 11 12 13 14 15 3.3%

10.0%

16.7%

23.3%

30.0%

36.7%

43.3%

50.0%

56.7%

63.3%

70.0%

76.7%

83.3%

90.0%

96.7%

K-AJ~A~

2.( 10-7 Sub itted by Date

/-\\-L-\\]

J Revit!we, by/D e

FREQUENCY PLOT FOR STRONTIUM-90 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm Mean: 1.2 1 E-02 pCi/g Frequency Plot For Sr-90 C.)

U) 0*

U)

I..

LL 6

5 4

3 2

-4.68E-03 4.23E-03 1.32E-02 2.21E-02 3.10E-02 3.99E-02 Upper End Value (pCi/g) 0 Upper End Observation Observation Value Frequency Frequency

-4.68E-03 3

20%

4.23E-03 3

20%

1.32E-02 1

7%

2.21 E-02 2

13%

3.I1OE-02 5

33%

3.99E-02 1

7%

Total:

15 100%

.TKOU.)tAle

'5UI JO?2 Su mitted by ate Reviewed by/Date' 1 of 1

QUANTILE PLOT FOR TECHNETIUM-99 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm Mean: 1.13E+00 pCi/g Quantile Plot For Tc-99 C0 0u Q~

1.80E+01 1.60E+01 1.40E+01 1.OOE+01 8.OOE+00 6.00E+00 4.00E+00 1.40E+01 I

~--~-

7' 2.OOE+00

~7iI1I---------------------------------

0.OOE+00

~-E

-U--U---

-2.00E+00


~

20 40 100 0

20 40 60 80 100 Percentage Tc-99 Rank Percentage

-2.41 E-0lI

-9.98E-02 6.58E-03 4.11 E-02 5.84E-02 7.39E-02 7.59E-02 8.99E-02 9.90E-02 1.04E-01I 1.42E-01 1.46E-0 1 1.62E-01 1.64E-01 1.62E+01 1

2 3

.4 5

6 7

8 9

10 11 12 13 14 15 3.3%

10.0%

16.7%

23.3%

30.0%

36.7%

43.3%

50.0%

56.7%

63.3%

70.0%

76.7%

83.3%

90.0%

96.7%

.2W-kA-r,<

.VJA 1, aI1?-i )0-7 Sub rteby/Ia_

Reviewed by/Date

FREQUENCY PLOT FOR TECI-INETLUM-99 Survey Unit: 9312-0005 Survey Unit Name: RCA - Former Tank Farm Mean: 1. 13E+/-00 pCi/g Frequency Plot For Tc-99 16 14-

~12-S10 S6-1LL4 2

0 2.50E+00 5.24E+00 7.98E+00 1.07E+01 1.35E+01 1.62E+01 Upper End Value (pC i/g)

Upper End Observation Observation Value Frequency Frequency 2.50E+/-00 14 93%

5.24E+00 0

0%

7.98E+00 0

0%

1.07E+/-01 0

0%

1.35E+01 0

0%

1.62E+/-01 1

7%

Total:

15 100%

St I IIIILLMU UY UdL

ý 5

q Reviewed by/Date 1o 1 of 1

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Revision 0

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121 -001 Attachment 8, Rev.CY-QO1 MAJOR Sign Test Calculation Sheet for Multiple Radionuclides Survey Area Number:

9312 Survey Unit Number:

0005 WPIR #:

N/A Survey Area Name:

Tank Farm (RCA)

Classification:

1

ýTYPE I (a error):

0.05 N:15 Radionuclides:

1 s Rad ion ucl ide 2 n" Radionuclide 3rd Radionuclide 4th Radionuclide Cs-137 Co-60 Sr-90 Tc-99 DCGL:

4.75E+00 2.29E+00 9.30E-01 7.60E+00 Results 1St Results 2nrd Results 3 rd Results 4t1h Weighted Sum 1 -W, Sign Radionuclide Radionuclide Radionuclide Radionuclide (We)

(pCi/g)

(pCi/g)

(pCi/g)

(pCi/g) 3.82E-03

-1.16E-02 2,28E-02 1.64E-01 0.04 0.96

+ 1 1.51 E-03 1.74E-02 2.87E-02 4.11IE-02 0.04 0.96

+1I 2.65E-02

-1.14E-02 1.87E-02 7.39E-02 0.03 0.97

+ 1 2.38E-03

-3.79E-03

.-1,36E-02 5.84E-02

-0.01 1.01

+ 1 5.86E-04

-1.63E-03 4.01 E-03 1.04E-01 0.02 0.98

+1

-2.47E-02 7.33E-03

-5.12E-03

-9.98E-02

-0.02 1.02

+1 2.11 E-02

-8.37E-03

-1.30E-02 1.46E-01 0.01 0.99

+ 1 2.93E-04 2.30E-03 3.99E-02 1.42E-01 0.06 0.94

+ 1 __

8.59E-03 2.63E-03 2,28E--0-2 9.90E-02 0.04 0.96

+ 1 __

2.02E-02 9.77E-03 5,77E-04 8.99E-02 0.02 0.98

+ 1 __

1 46E-02 2.48E-03 2.48E-02 7.59E-02 0.04 0.96

+1

-5.70E-03 8.34E-03 1.30E-03 6.58E-03 0.00 1.00

+1 1.32E-02 8.76E-04 9.93E-03 1.62E-01 0.04 0.96

+1 2.37E+00 Z.61 E+00 2.67E-02 1.62E+01 3.80

-2.80

-1 ___

2.01 E-02 6.79E-03 1 36E-02

-2.41 E-0 1

-0.01 1.01

+1 Number of positive differences (S+)l 14 ---

Critical Value 11 Su David Wotlw rvey U nit Meets the Acceptance Criteria Performed by:

Independent Revie~Nv by:

j2 C, A.,ý dk.

Date:

Date:

3/26/2007 Page 1 of 1

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Revision 0

Health Physics Procedure 2,1265-000-(jPP-(jGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-(3GGR-R5 124-000-Rev.CY-O00 AtCachment A Split Sam ple Assessmient Form Survev Area #:

9312 Survey Unit #

0005 Survey Unit Name:

R-CA - Tank Farm Sample Plan or WPMR:

N/A ISIA 3200-1 Sample

Description:

Comparison of split samples collected from sample measurement location 1111 and analyzed using gamma spectroscopy by off-site Vendor L-aboratory. The standard sample was 9312-0005-011 IF, the comparison sample was 9312-0005-01 11 FS.

sTrANDARD COMPARISON Raincie Activity Standard Reouin Agreement Activity Standard Comparison Acceptable Raincie Value Error Reouin Range Value Error Ratio (Y/N)

K-40 I.4+/-l 0.427 24 0.75-1.33 9.87E+00 0.4 17 0,95 Y

Conirents/Corrective Actions: Cs-137 was not detected in sufticient quantities in the field split results at location 9312-0005-01 IF to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the tield-split results at these locations. Since K-40 was found to be present at an accep~table level of agreement, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.

FEesgo-ut0-0n 4-7I 8-15 16 -50 51 -200

>200 Aarremj)!Zt Raag 0.5 -2.0 0.6-1,66 0.75 -1.33 0.80 -1.25 0.85. -1.12

-- I by:

[Date:

'3(<

Page I of I

FORMER RADIOLOGICALLY CONTROLLED AREA TANK FARM SURVEY UNIT 93 12-0005 RELEASE RECORD ATTACHMENT 4E (COMPASS POWER CURVE)

Revision 0

DQA Surface Soil Report Assessment Summary Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples-Reference Area Samples:

Test Performed Judgmental Samples:

Assessment

Conclusion:

9312 Wojo 9312-0005 1

15 0

Sign Test Result:

Pass 0

EMVC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve C

0.9 S0.8

~0.7 S0.6 0.5 0.4 0O.3

~-0.2 S01 ZJII huh

____~-

-~__

11111

-I-

-~

-I--

-3

-U---

711th___-_

3.0 0.2 0.4 0.6 0.8 1.0 1 2 Unity Rule Sum-of-Ratios, incliuding background Prospective Power 0

1-beta Actual Power LBGR Estimated Power DCGL Retrospective Power 1 4 COMPASS 0l.0.0 32107Pg 3/27/2007 Page 1