Final Status Survey Final Report Phase VI Appendix Al 5 Survey Unit Release Record 9539-00019 ISFSI Haul Road February 2007 CI
CYAPCO FINAL STATFUS SURVEY RE.LEASE RECORD IISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 Prepared [ . ..)J. WiAV Date: 1/Z3 /07 Reviewed S Engeerate: 123A7T S Engineer Approved By: _____ Date: / ý?
Technical Support Manager Revision 0
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD TABLE OF CONTENTS
- 1. SURVEY UNIT DESCRIPTION ...................................................... 3
- 2. CLASSIFICATION BASIS ............................................................... 3
- 3. DATA QUALITY OBJECTIVES (DQO) .......................................... 6
- 4. SU RV EY D ESIGN ............................................................................. 9
- 5. SURVEY IMPLEMENTATION ....................................................... 12
- 6. SU RV EY RESU LTS ........................................................................ 13
- 7. QUALITY CONTROL .................................................................... 18
- 8. INVESTIGATIONS AND RESULTS ............................................. 18
- 9. REMEDIATION AND RESULTS ................................................... 18
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .......... 19
- 11. DATA QUALITY ASSESSMENT (DQA) ....................................... 19
- 12. AN O M A L IE S .................................................................................... 20
- 13. CONCLUSION ...................................... 20
- 14. ATTACHMENTS .................................... 21 14.1 Attachment 1 - Figures (8 pages including cover) 14.2 Attachment 2 - Scan Results (7 pages including cover) 14.3 Attachment 3 - Laboratory Data (97 pages including cover) 14.4 Attachment 4 - DQA Results (13 pages including covers)
TOTAL 146 Revision 0
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9539-0001, which encompasses the northern portion of the access road to the Independent Spent Fuel Storage Installation (ISFSI) and the Southeast Landfill Area is designated as Final Status Survey (FSS) Class 2 and consists of approximately nine thousand three hundred thirty-two (9,332) square meters of open land and is located approximately one thousand, three hundred forty-four (1,344) feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1).
The survey unit is an open land area located along the east shore of the Discharge Canal from the non-protected area southeast grounds of the site to the ISFSI vehicle barrier. The survey area is a narrow strip of land encompassing the access road and 25 feet on both sides of the road. A minimal amount of brush and trees remain in the survey area. The area topography consists. mostly of steep, rocky or vegetated hillsides. A majority of the trees have been cleared for the construction of the access road. The ISFSI access or "Haul" road crosses north to south through this survey unit.
The survey unit is bounded as follows: land Survey Unit 9522-0001 to the north (called north as oriented with the north to south flow of the Connecticut River),
the Discharge Canal to the west, land Survey Unit 9539-0002 to the south, and land Survey Unit 9532 to the east.
Work activities to support the ISFSI access road construction have occurred in this survey unit. These activities included tree and stump removal, silt fence installation, soil removal, grading and rock blasting. Hillsides grading left some locations showing a steeper incline. Rock shelves and outcroppings were located along the hillside, especially in the east and south. There are occasional voids along the access road where the grading process has stripped away underlying rock.
The reference coordinates associated with this survey unit are E009 through E014 by S081 through S096 (refer to "HNP License Termination Plan" (LTP) Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
- 2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."
The "Classification Basis Summary" conducted for Survey Unit 9539-0001 consisted of:
a) A review of the 10CFR50.75 (g) (1) database, Revision 0 3
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD b) A review of the "InitialCharacterizationReport" and the "HistoricSite Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walk-down."
A review of the "Initial and Supplemental CharacterizationReports" as well as the previous "Classification Basis Summaries" was performed. Survey Area 9539 was previously designated as Survey Area 9528. Survey Unit 9539-0001 is the northern portion of Survey Area 9539 and includes the former Survey Unit 9528-0002 and a portion of 9528-0003. Survey Area 9528 was initially designated as Class 3 during the development of the LTP. The source documents, the "Connecticut Yankee Haddam Neck CharacterizationReport" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0.
The second source document justified a Class 2 designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class 2 designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".
The historical documents (e.g., the 10CFR50.75(g)(1) files) identify a number of events that may have impacted this survey unit. In the past, the public was granted access to this area for recreational purposes (e.g. hiking). Typical debris and litter (soda bottles, fishing line, etc.) were found in the area. From time to time, 55-gallon drum trash containers were positioned along the Canal Road to.
collect and control litter.
In December of 2001, scan surveys in an area along the road indicated the possible deposition of radioactive material in an unauthorized location (CR 01-0490). In March of 2002, investigative soil sampling was performed in the area where elevated scan results were observed. The soil sample results identified low-level plant-related radioactive material (Co-60). The presence of Co-60 was not expected as this area was previously identified as Survey Unit 9528-000, a Class 3 area (CR 02-0125).
Although measurement results were very low relative to the DCGL, soil containing the Cobalt-60 were removed from the area as a prudent measure.
Approximately twenty-five (25) cubic meters of soil was removed for disposal as waste. Post excavation soil sample analyses results did not identify any remaining residual activity. Based on the findings of the survey and the subsequent remediation, Survey Unit 9528-0000 was reclassified as a Class 2 open land area. In accordance with the survey unit size limitations in the License Termination Plan (LTP), Survey Unit 9528-0000 was subdivided into three (3) new survey units designated as 9528-0002, 9528-0003 and 9528-0004.
Revision 0 4
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Low-level licensed material from the plant and the Offsite Material Recovery Program (OMRP) utilized the canal roads as a route to the Southeast Landfill and Material Storage areas. Sample data associated with the OMRP identified two (2) Hard-to-Detect (HTD) radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).
However, the reported concentrations of Ni-63 and Fe-55 were a very low fraction of the applicable Base Case Derived Concentration Guideline Level (DCGL) for soil (<1%). Other radionuclides were not expected to be present in any significant percentage of their DCGL.
In July of 2002, Survey Units 9528-0002, 9528-0003 and 9528-0004 were subjected to FSS under Work Plan and Inspection Record (WP&IR) 24265-000-GEN-0002-00104-000. FSS consisted of surface soil samples and scan measurements. Scan surveys were performed with an Eberline E-600 using a SPA-3, 2"x2" sodium iodide detector.
Fifteen (15) surface soil samples were collected from each of the three (3) survey units contained within Survey Area 9528. During scanning, several areas were identified with slightly elevated readings, which prompted the collection of additional investigation soil samples ,from these areas. All samples were collected and analyzed by gamma spectroscopy by an approved off-site laboratory.. -Nine (9) of the forty-nine (49) total samples collected were analyzed for "Hard-to-Detect" (HTD) radionuclides. Cs-137 and Co-60 were the primary radionuclides detected in the sample population. No HTD radionuclides were positively identified. FSS results from 2002 demonstrated that all three (3) survey units were acceptable for unrestricted release. The sample analysis results from the 2002 FSS survey are provided in Table 1.
Table I- Sample Analysis Results from 2002 FSS Soil Samples - .
Cs137 Co-60
>x> (pCi/g) (pI/g Minimum Value: -2.02E-02 -1.37E+00 Maximum Value: 1.20E+00 6.3 1E-01 Mean: 2.59E-01 7.84E-03 Median: 1.04E-01 3.38E-03 Standard Deviation: 3.05E-01 2.19E-01 In 2006, a decision was made to reuse milled asphalt media by using the material to grade, build and repair the ISFSI haul road. The asphalt was a byproduct of demolition activities in various areas of the site. The material had been stock-piled awaiting disposal. Prior to introducing the material into the survey area, volumetric samples were taken and analyzed by gamma spectroscopy. Low levels of Cs-137 and Co-60 were detected. However, as the origin of the material was from impacted areas and the volumetric samples were not completely Revision 0 5
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD representative of all the material that was deposited, the previously performed FSS in Survey Area 9528 was invalidated. Survey Area 9528 was subsequently renamed as Survey Area 9539 to support the resurvey.
The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon a review of the historical information and the results of the Characterization Survey data, it was concluded that there was a low probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 2 (refer to Section 3).
- 3. DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS plan.
The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9539-0001 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.
Revision 0 6
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.
Equation 1 HTotal =Hsoil + HExistingGW + HFutureGW The total dose under the LTP criteria is twenty-five (25) mremlyr TEDE from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.
CY memo ISC 06-024 addresses the impact of existing and future groundwater on specific survey areas at CY. Survey Area 9539 is not specifically addressed by this reference. However, CY memo ISC 06-024 does state that Survey Area 9528 is affected by existing groundwater and is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining, within the groundwater saturated zone in the area.
Since Survey Area 9528 became Survey Area 9539, the dose contribution from existing and future groundwater will impact Survey Area 9539 in the same manner as it did Survey Area 9528. Therefore the dose contribution from existing groundwater in Survey Unit 9539 is bounded by two (2) mrem/yr TEDE and the dose contribution from future groundwater, the third dose component, is zero (0) mremlyr TEDE.
Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mremnyrExisting GW+ 0 mrem/yrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL (DCGLop), and has been established for the radionuclides of concern as provided in Table 2.
Revision 0 7
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD
~Table 2 -& Radionuclide Specific Base Case Soil DCGI~s, Oper~ational DC(,Ls and Req*ired Minimum*tDetectabile Concentrations (MDCs)
~RadionuclideBase Case Soil Operational DCGL' Requ;Lired N.
H-3 4.12E+02 2.80E+02 1.65E+0l C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-0 I Ag-I 08m 7.14E+00 4.86E+00 2.86E-01 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu- 154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Am-241 (5) 2.58E+O1 1.75E+01 1.03E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Cm-243/244 2.90E+0 1 1.97E+01 1.16E+00 (1) Bold indicates those radionucldies considered Hard to Detect (HTD)
(2) The Base Case Soil DCGL(s) are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to achieving seventeen (17) mrem/yr TEDE (4) The required MDC is equivalent to achieving one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed Revision 0 8 Revision 0 8
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Soil samples were collected in 2002 as part of the previous FSS to establish the radiological condition of Survey Unit 9539-0001. Cs-137 and Co-60 were the only two (2) gamma emitting radionuclides reported in concentrations with the potential for exceeding the screening criteria. No HTD radionuclides were positively identified. The previous FSS data were used for this survey design and are provided in Table 1.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5. 1-11, "Preparationof Final Status Survey Plans".
The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
The DQO process determined that both Cs-137 and Co-60 would be the radionuclides of concern in Survey Unit 9539-0001 (refer to Section 3). The characterization survey did not identify any HTD radionuclides of concern for this survey unit. Subsequently, surrogate DCGLs were not required for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design. Radionuclide screening or de-selection is a process where the dose contribution from an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.
Revision 0 9
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.8 to maintain the relative shift (A/a) in the range of 1 and 3. The resulting relative shift was 2.00. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the-decommissioning license termination rule (IOCFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing. Based upon a review of the historical information and Characterization Survey data, the acquisition of additional judgmental surface soil samples from within this survey unit was deemed unnecessary.
The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locationsfor FinalStatus Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
Tabl'e 3 - SarniilvMeastirentieiit Locations with Associated GPS coor~dinates >
Designation ~ N~orthing& E~asting 9539-0001-OOIF 236053.33 669498.22 9539-0001-002F 235977.12 669630.22 9539-0001-003F 235900.91 669762.21 9539-0001-004F 235900.91 670202.21 9539-0001-005F 235900.91 670290.21 9539-0001-006F 235900.91 670378.21 Revision 0 to Revision 0 10
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Table 3 -~ (continued
-,Designation > _ N ort*hii. Easting 9539-0001-007F 235900.91 670466.20 9539-0001-008F 235900.91 670554.20 9539-0001-009F 235824,.70 669894.21 9539-0001-O0OF 235824.70 669982.21 9539-0001-01 IF 235824.70 670686.20 9539-0001-012F 235824.70 670774.20 9520-000'1-013F 235748.49 670906.20 9539-0001-014F 235748.49 670994.20 9539-0001-015F 235672.28 671126.19 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of one (1) soil sample for "split sample" analysis by the off-site laboratory. This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.
The LTP specifies a required scanning coverage of 10% to 100% for outdoor Class 2 areas. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Based on the historical site assessment, the characterization data available, and the use of this survey unit, it was determined that scanning was required in six (6) separate areas. The total surface area to be scanned was approximately 25% of the survey unit. A map of the scan grid locations is provided in Attachment 1.
For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.
Revision 0 11
)
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Table 4 - Synopsis of the Survey Design
- Featur~e* : *:Design Criteria Basi Survey Unit Land Area 9,332 m2 Based on AutoCAD-LT Type 1 and Type 2 errors were 15 0.05, sigma was 0. 10 pCi/g, the Number of Measurements 15 LBGR was set at 0.8 to maintain (15 systematic grid) Relative Shift in the range of 1 and 3 Grid Spacing 26.85 m Based on triangular grid 5.38 pCi/g Cs-137 Administratively set to achieve Operational DCGL 2.59 pCi/g Co-60 seventeen (17) mrem/yr TEDE "'
The Operational DCGL meets the Soil Investigation Level 5.38 pCi/g Cs-137 LTP criteria for a Class 2 survey l2.59 pCi/g Co-60 unit Scan Survey Area Approximately 25% The LTP requires >10% area Coverage of the area coverage for Class 2 survey units Detectable over Administratively set to achieve Scan Investigation Level background seventeen (17) mremryr TEDE *
(1) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)
- 5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0048. The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Six (6) scan areas were established that constituted approximately 25% of the surface area of Survey Unit 9539-0001. Grid lines, one meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 4,290 counts per minute (cpm) up to 9,620 cpm.
The scan areas were established and scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to Revision 0 12
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 25% of the survey unit was scanned.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.
Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media 1or Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Two (2) samples (9539-0001-OOIF and 9539-0001-007F) were randomly selected for HTD radionuclide analysis.
The implementation of survey specific quality control measures included the collection of one (1) sample (9539-0001-003F) for "split sample" analysis.
- 6. SURVEY RESULTS All field survey activities were conducted between January 3, 2007 and January 9, 2007.
The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations. Scan results for the entire survey unit are provided in Attachment 2.
Table 5 Scan ZResults for Sample Measurement Locations
. Sample Highest Logged A 0 Level121 ..
NleaurenenReýadiiig (kpn - >Action Level~~~~
____________ ~ (kcpi-) 7K 1 5.9 6.8 NO 2 5.4 6.5 NO 3 7.4 8.8 NO 4 5.8 7.2 NO 5 5.7 7.3 NO 6 6.9 6.5 YES 7 6.8 8.4 NO 8 10.1 10.8 NO Revision 0 13
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Table 5 - (continued)~ ~
Sample Highest Logged Measurement: Reading (kpi Action Level>
LocationfW (kcpm)<(km)' __
9 5.3 6.6 NO 10 5.2 7.1 NO 11 6.3 8.5 NO 12 10.0 10.1 NO, 13 9.4 9.7 NO 14 11.5 11.4 YES 15 7.7 8.5 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level. Sample locations 9539-0001-006F and 9539-0001-014F were moved accordingly.
The scan areas, that comprised approximately 25% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on January 4, 2007 through January 9, 2007. Several elevated measurement locations were identified during scanning.
Table 6 provides an overview of the scan area survey. Complete scan results are provided in Attachment 2.
Table.6 - Scan Area Results. . . ; -,< . ..... , . ,, ,
High'st SCan Scan Logged ElevatedReadingI,,,
Ldig Level (1)' liaý edigIvsiain Area .7 tirips Reading) Ivdentification Sample 1 1-12 6.00 6.30 None None I
2 1-13 5.75 7.51 None None Log # 75 from download # 010407- 9539-0001-0161 1110 afternoon 3 1-13 10.50 6.94 Log # 76 from download # 010407- 9539-0001-0171 1110 afternoon Revision 0 14
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Table 6o- (continu:ed)
,Highest Acio Sn SaW ScnScnLevel Logged At "ng Elevated Readin netgto InesiatI Area Strips Reading (kcm ) (lcp m1);* "> Identification :, Samiple
+.....
4 1-11 5.44 6.36 None None Log #24 from 9539-0001-0181 download # 0 10907-1114 afternoon Log #26 from 9539-0001-0191 5 1-11 12.70 8.79 download # 010907-1114 afternoon Log #02 from 9539-0001-0201 download # 010907-1114 afternoon Log #02 from 6 1-11 9.36 7.61 download # 010507- 9539-0001-0211 1115 afternoon (1) The action level is based on a measurement above ambient background The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field split and the six (6) investigation samples using gamma spectroscopy. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).
However, Cs-137 and Co-60 were the only gamma-emitting radionuclides reported in concentrations exceeding the de-selection criteria.
Cs-137 was identified in ten (10) and Co-60 was identified in two (2) of the fifteen (15) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.
Revision 0 15
1SFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Table 7 - Sirummary of GammaSpcrsoyRulsfrufaeoi Samplles Comiprising the StatistialSSample Populaton il Sample Number C-3 K
~pCig pcijg 9539-0001-OO1F 1.67E-0 1 -2.35E-03 9539-0001-002F -2.12E-03 -8.86E-03 9539-0001-003F 1.74E-01 -4.43E-03 9539-0001-004F 3.66E-02 2.81E-02 9539-0001-005F -3.46E-03 9.64E-03 9539-0001-006F -3.05E-04 4.13E-03 9539-0001-007F 5.79E-02 1.76E-02 9539-0001-008F 1.34E-01 1.65E-02 9539-0001-009F 9.71E-02 4.59E-02 9539-0001-OlOF 3.76E-02 4.25E-03 9539-0001-01 IF -4.03E-03 -4.03E-03 9539-0001-012F 2.34E-0 1 -4.33E-03 9539-0001-013F 0.OOE+00 5.1OE-03 9539-0001-014F 7.73E-02 1.56E-02 9539-0001-015F 3.06E-02 8.23E-03 The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.
Tc-99 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in one (1) of the two (2) samples analyzed for HTD radionuclides. In accordance with LTP Section 5.4.7.2, "Gross Activity DCGLs",
the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. For Tc-99, the Operational DCGL is 8.57 pCi/g to achieve a TEDE of seventeen (17) mrem!yr. The positive analytical result for Tc-99 equated to 4.5% of the Operational DCGL. Subsequently, Tc-99 was deselected as a radionuclide of concern for this survey unit.
Revision 0 16
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD The "sum-of-fractions" or "unity rule" is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The unity rule is:
Equation 3 Ci 4-
+ C2 +2 C ,, *1" DCGLI DCGL2 DCGL,I Where: CQ1 = concentration of radionuclide n and DCGLn = DCGL of radionuclide n.
The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9539-0001 are provided in Table 8 below.
Table 8 -Resultsý.of Unity Calculation for. Surface SolSape Com$prisi ng teStatistical Sample Population Sminple. Number Fraction of th prtinlDG Unity Fractionl Cs17Co-60 9539-0001-O0IF 0.03 0.03 9539-0001-002F - -
9539-0001-003F 0.03 - 0.03 9539-0001-004F 0.01 0.01 0.02 9539-0001-005F - -
9539-0001-006F - -
9539-0001-007F 0.01 - 0.01 9539-0001-008F 0.02 - 0.02 9539-0001-009F 0.02 0.02 0.04 9539-0001-O0OF 0.01 - 0.01 9539-0001-01 IF - -
9539-0001-012F 0.04 0.04 9539-0001-013F -
9539-0001-014F 0.01 0.01 9539-0001-015F 0.01 0.01 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 to achieve seventeen (17) mrem/yr TEDE respectively.
(2) -indicates that the radionuclide was not positively detected in the sample Revision 0 17
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD
- 7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. One (1) sample location was selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". There was acceptable agreement between the field split results at location 9539-0001 -003F.
The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 4 for data and data quality analysis results.
- 8. INVESTIGATIONS AND RESULTS Six (6) investigative samples were collected from scan area 3, scan area 5 and scan area 6 at locations exhibiting elevated scan readings. The samples are denoted as shown in Table 6, with the sample results shown in Table 9 below.
Table 9- IvsiaveSaimple Resuilts~ '7 Sample N~umber' Cs-137 2~Co-6OUnt Fatin 9539-0001-0161 2.44E-02 5.30E-03 -
9539-0001-0171 5.28E-02 -3.08E-03 0.01 9539-0001-0181 3.88E-02 -2.87E-03 0.01 9539-0001-0191 1.15E-01 -1.3 1E-02 0.02 9539-0001-0201 2.39E-01 6.70E-03 0.04 9539-0001-0211 1.78E-02 9.21 E-04 0.00 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 to achieve seventeen (17) mrem/yr TEDE respectively.
(2) - indicates that the radionuclide was not positively detected in the sample
- 9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
Revision 0 18 Revision 0 18
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan for this survey unit.
- 11. DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "DataQuality Assessment, "for completeness and consistency. The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 10.
T*able10- *Basic Statistical Quantities for:Cs-137 and Co-60 from the Final Status Survey.
Cs-137Co-60 PCi1g _C/
DCGLop: 5.38E+00 2.59E+00 Minimum Value: -4.03E-03 -8.86E-03 Maximum Value: 2.34E-01 4.59E-02 Mean: 6.91E-02 8.74E-03 Median: 3.76E-02 5.1OE-03 Standard Deviation: 7.64E-02 1.45E-02 For Cs-137, the range of the data, about three (3) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected. The difference between the mean and median was about 41% of the standard deviation which indicates some skewness in the data. The data was represented graphically through postinig plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 0.91 for Cs-137.
Revision 0 19 Revision 0 19
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD Co-60, although included in the FSS plan for compliance purposes, was positively identified in only two (2) of the fifteen (15) samples collected for non-parametric statistical testing. Assessment of the basic statistical quantities and graphical representation of Co-60 was not considered useful giyen the limited number of data points to represent the distribution.
All data, assessments, and graphical representations are provided in Attachment 4.
- 12. ANOMALIES No anomalies were noted.
- 13. CONCLUSION Survey Unit 9539-0001 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.
All identified radionuclides of concern were used for statistical testing to determine the adequacy of the survey unit for FSS.
The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 2.
The dose contribution from soil is 0.276 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 2.276 mremnyr TEDE. Therefore, Survey Unit 9539-0001 is acceptable for unrestricted release.
Revision 0 20 Revision 0 20
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD
- 14. ATTACHMENTS 14.1 Attachment I - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 21
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 1 (FIGURES)
Revision 0
Legeno Wet Land Notes o 500 1000 Notes Coordibates are in
- .I 953' NAD27 Connecticut State Plane System Connecticut Yankee Atomic Power Company Survey Unit 9539-0001
\'
Legee, 95391-0001 = Sample Location Wet Land Notes 0 75 150 Feet Notes Cooreinatesarein 95s2o-0003 ,* \ / NAD27 Cnoneccut State PlateSystem Connecticut Yankee Atomic Power Company Sample Location Map for Survey Unit 9539-0001
9539-0001 90'-
Resultin p C4/
= Wet Land Notes 0 75 150 Fen F
Notes Coordinates arein 952041003 NAD27 Connecticut State PlaneSystem Connecticut Yankee Atomic Power Company 9539-0001 FinalStatus Survey Design Cesium-137 Posting Plot
4.
9539-0001 Legend
= Soil Snople Result in p Ci/g Wet Land Notes 0 75 150 1-11111- " Fee, Notes Coordinatesate in NAD27 Connecticut State Plane System Connecticut Yankee Atomic Power Company 9539-0001 FinalStatus Survey Design Cobalt-60PostingPlot
0 =Sample Location
.Wet Lond Notes 0 75 150 Fmt Notes Coordinatesare in NAD27 Canmctircut State Plane System Connecticut Yankee Atomic Power Company Investigative Sample Location Map for Survey Unit 9539-0001
9539-0001 Legen-d
= Soil Sonple Result in p Ci/g
= Wet Land Notes 0 75 150 F.t*
Notes Coordiontes ore in NAD27Cooneeticut State Plane System Connecticut Yankee Atomic Power Company 9539-0001 FinalStatus Survey Design Investigative Cesium- 137 PostingPlot
9539-0001
= Soil SoMple Result in p CMg Wet Lend Notes 0 75 150 Fete Notes Coordonatesore in NAD27 Cormecticut State ploe System Connecticut Yankee Atomic PowerCompany 9539-0001 FinalStatus Survey Design Investigative Cobalt-60Posting Plot
K Lýnd W&tLand Not.
0 too 20 Not Coodinate -r in NAD27Connctcdct StwtPl-n System Connecticut Yankee Atomic Power Company Scan Area Locations for Survey Unit 9539-0001 June 2007 Rev. I
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
Revision 0
Survey Unit 9539-0001 Scan Area #01 Strip Scan Results 010407-1110 scan area 1 010407.xls 1 1/30/2007
Survey Unit 9539-0001 Scan Area #02 Strip Scan Results Scan Strip Type Log Log Date Log Time Reading Action >Action E-600 SIN T Probe SIN Area Number Reading Number I (cpm) Level Level I IBC 26 1/4/2007 10:36:00 1 5.17E+03 I 1 1110 1010 2 1 27 1/4/2007 10:36:00 5,73E+-03, 6.20E+0311000 BC 28 1/4/2007 10:36:00 6.37E+03 1110 1010 2 2 SC 29 1/4/2007 10:37:00*0105,75E+03 7.51:E+03 1110 BC 30 1/4/2007 10:38:00 5,83E+03 1110 1010 2 3 SC 3'1 1/4/2007 10:38:00 5.41 E4 03 6.92>E+03 - 11>10, 10~10 BC 32 1/4/2007 10:38:00 5.04E+03 2 4 BC 33 1/4/2007 10:39:00 5.41E+03 05E+03 1110 1010 I
BC 3 1/4/2007 10:40:00 5.OOE+03 ,1110 1010 2 5 SC 35 1/4/2007 10:41:00 4.35E+03i 601 E+03 :1110 1010 BC 36 1/4/2007 10:42:00 4.59E+03 1110 1010 2 6 SC >< 37' 1/4/2bbj7 10:42:00 4,49E+03 5.56E+03 . >,1110 11 BC 38 1/4/2007 10:43:00 4.96E+031 1110 1010 27St39 Y 1/4/200'7 10'43:00 >4.57E+03~ 597E+0 13 ii10>
1 1010<
BC 40 1/4/2007 10:44:00 4.63E+03 1110 1010 2 8 SC <41 <:,*1/4/2007 120:45:00 4,55E+03 5,60E+.03 1110 1010 BC 42 1/4/2007 10:46:00 4.40E+03 1110 1010 2 9 SC ~43 ~ 1,24/2ob7 10:47:00' 4,24E+03' 5 35E+0311000 2BC BC 44 45 1/4/2007 1/4/2007 10:47:00 1 0 4 29E+03 4,81E+03 5.23E+03 1110 1010 I BC 4614207 1'0:48:00 [ 450E+0311000 2 11 'SC , ">47 1/Y4/2007 10:49:00~ 4.51 E+03 5.46E+03 1110 1010' I BC 48 1i/4/2007 110:49:00 1 4.8I6E+0311000 2 12 ~ SC j ~49 1/4/2007~ 10:50:00' 4.24E+03 ,5.86E+03 .1110 '1010 IC50 1~1/42007 10:50:00 6.21 E+03I 1110 1010 2 13 SC 51 1t/>4/2007~10:52:00 5.04E+03 ~7.34E+03 i1110 101>0 010407-1110 scan area 2 010407.xls 1 1/30/2007
Survey Unit 9539-0001 Scan Area #03 Strip Scan Results Scan Strip Type Log Log Date Log Time Reading f Action >Action E-600 SIN Probe SIN Area Number Reading Number (cpm) Level Level _ __
BC 52 1 1/4/2007 13:28:00 15.33E+03 1 1110 1 1010 3 1 ~.SC ~53 1/4/2007 1330:00 T4.87E+b3 -6.37E+03 1I lb0~ 1010 BC 54 1/42007 13:30:00 7.67E+03 M1G0j 1010 3 2 SC 551,4/2007 13:33:00~ 6,9E0 8.2E0 1ii-0 10d10 BC 56 1/4/2007 13:36:00 5.95E+03 Ill() 1 10 3 3 SC 57 114/2007 113:8ý00 ~5.63EQ3~ 7.05E+03 ll() ~101'0 BC 1/4/2007 13:39:00 5 03E+03 IM) 1010 3 4 SCQ 59 11412007 13:41:ý00 ~5.05Eý03~ 6,04E'+03 Il) 11 BC 60 1/4/2007 13:42:00 5.40E+03 (1110 1010 3 C!114/2b7, 1A3:44.00~ 4.93E+03 6.45E+03 111lO lo101 BC 62 1/4/2007 13:45:00 4.64E+03 1110 1010 3 6 ;13:50:00631
, ,/4/2007> .5.61.E+03 5.1543E+03 -i1110. 1010 IBC 64 1/4/2007 13:51:00 4.92E+03 1110 1010 3 7 SC 65 11412007~ 113:030 ~4.94E+03~5.92E+03 111 1010 BC 66 1/4/2007 13:53:00 5.30E+03 . 1110 1010 3 8 C, 67 1/4/2007 16 5.17.6.34E+03 1110 1010 BC ! 68 1/4/2007 13:57:00 5.14E+03 1110 1010 3 9 i. SC " < 69 ' , 1/4A!207 .13:59:001 4,30E+03 6.i16E+03 -. 1.110 1010*
BC 70 1/4/2007 14:00:00 4.92E+03 MO 1010 3 10BC 71 1/4/2007 14:02:00 4,78-A2- E+03 1110 1010 B-C 74 1/4/2007 14:07:00 5.45E+03 1110 101 BC 76 1/4/2007 14:12:001 5.85E+03 1110 1010 3 13 SC 75 1/4/207 14:9:00 5 4E03 6.501t+03 1110 1010 ER 78 1/4/2007 14:20:00 7.84E+03 1110 1010 3 ER 79 1/4/2007 14:21:00 1.05E+04 1110 1010 010407-1110 scan area 3 010407.xls 1 1/30/2007
Survey Unit 9539-0001 Scan Area #04 Strip Scan Results Scans Strip -TypeFLog Log Date Log Time Reading Action' > Action [E-600 SIN Probe S/N Area Number Reading Number (cpm) Level Level
'BC 1 1/5/2007 7:50:00 5.62E+03 1 1110 1010 BC 3 1/5/2007 7:53:00 5.32E+03 1110 1010 4 2 SC 4 1/5/2007 7:55:00 5.44E+0.9 6.36E3+03 1110 1010 BC 5 1/5/2007 7:55:00 4,59E+03 1110 1010 BC 6 1/5/2007 7:57:00 4.06E+03 5.56lE+ 7< ,1110 1010 BC 7 1/5/2007 7:T5:00 4.75E+03 5 1110 1010 BC 9 1/5/2007 7:59:00 4502E+03 1110 1010 4C 15 1/5/2007 8:04:00 5.01E03 6.03E+03 1110 1010 BC 11 1/5/2007 8:01:00 4.74E+03 K 1110 1010 4 6 SC 12 ?1/5/20~07 7 8:02:rib 4.69E+03 5.k72E+03 7~~i< 111 ,71010I BC 13 1/5/2007 8:02:00 4,52E+031 1110 1010 BC 15 :15/2ob7 ~8:041-00 4.32E+~03 5.48E+03 - /111b 1010 BC 1 1/5/2007 8:04:00 4.56E+03 1110 1010 4 8 SC 16 1, 5/2007 8 05:00 4.77~E+03 5.52E+03 . -1110 .1010 BC 17 1/5/2007 1806:00 5.10E+03 11 11 4 9 Sc7- 18 1/512007< #8:08:O00 5.11 E+03 6.12E+03> 111 ill blOo BC 19 1/5/2007j8&08:00 4,86E+03 11~~E0~10i'" ~1010~
4 10 SC 20 1/5/2007 8:10.00 5,15E+03 5.86E03 1110 1010 1BC 21 j1/5/2007 8:12:00 4.55E+03 I lil0 10,10 4 11 sC ~22-- -0/52667 '8:3-.0 4.70E0P3 5.51 E+03 11fl1 'b 101-b 010507-1110 scan area 4 010507.xls 1 1/30/2007
Survey Unit 9539-0001 Scan Area #05 Strip Scan Results 010907-1114 scan area 5 011507.xls 1 1/30/2007
Survey Unit 9539-0001 Scan Area #06 Strip Scan Results 010507-1112 scan area 6 011507.xls 1 1/30/2007
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
Revision 0
General Narrative 1
General Narrative for Connecticut Yankee Atomic Power Co.
Work Order: 178924 SDG: MSR#07-0035 January 15, 2007 Laboratory Identification:
GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on January 11, 2007 for analysis.
Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.
Sample Identification The laboratory received the following samples:
Laboratory Sample Identification Description 178924001 9539-0001-001-F 178924002 9539-0001-002-F 178924003 9539-0001-003-F 178924004 9539-0001-003-FS 178924005 9539-0001-004-F 178924006 9539-0001-005-F 178924007 9539-0001-006-F 178924008 9539-0001-007-F 178924009 9539-0001-008-F 178924010 9539-0001-009-F 178924011 9539-0001-010-F 178924012 9539-0001-011-F 178924013 9539-0001-012-F 178924014 9539-0001-013-F 178924015 9539-0001-014-F 178924016 9539-0001-015-F 178924017 9539-0001-016-I 178924018 9539-0001-017-I 178924019 9539-0001-018-I 178924020 9539-0001-019-1 178924021 9539-0001-020-1 178924022 9539-0001-021-1 GEL Laboratories LLc PO Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.766.1178 www.gel.com 2
Items of Note There are no items to note.
Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.
Analytical Request Twenty soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.
Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryo~nes Project Manager GEL Laboratories tic P0 Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.766.1178 www.goI.xom 3
List of current GEL Certifications as of 15 January 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01 151CA Colorado GenEngLabs Connecticut PH-0 169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)
Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S.' Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 4
Chain of Custody and Supporting Documentation 5
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Connecticut Yankee Atomic Power Company Chain of Custody Form No.. 2007-00001 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556:
ProjectName: Haddam Neck Decommissioning Analyses Requested LabU Use Only ContactName & Phone: Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 <
843556 8171. Attn. Cheryl Jones Priority: [-]30 D. ] 14 D. 0 7 D. [1 3 D.
Sample Container Size-TA Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9539-0001-001-F 01/03/07 0806 TS G BP X 9539-0001-002-F 01/03/07 0816 TS G BP X 9539'0001-003-F 01/03/07 0826 TS G BP X
,9539-0001-003-FS 01/03/07 0826 TS G BP X 9539-0001-004-F 01/03/07 0945 TS G BP X 9539-0001-005-F 01/03/07 0952 TS G BP X 9539-0001-006-F 01/03/07 0957 TS G BP X "__"_
9539-0001-007-F 01/03/07 1003 TS G BP X 9539-0001-008-F 01/03/07 1008 TS G BP X 9539-0001-009-F 01/03/07 1015 TS G BP X __.....
9539-0001-010-F 01/03/07 1020 TS G BP X NOTES: PO #: 002332 MSR #: SSWP# NA Z LTP QA . E3 Radwaste QA. Samples Shipped Via:
67-'03S" El Non QA Internal.Container.
Z Fed Ex Temp.: AS- Deg.
D uPS 1: Hand Custody ealed?
I) Relinquished By Date/Time 2) Re eived By Date/Time QCustody Seal lib/7 0 13 Other Intact?
- 3) Relinquished By Date/Timre 4) Reived By /Date/Time VY9< N 0 Bill of Lading #
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00.! Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-06002 362 Injun Hollow Road, East Hampton. CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab USý Only Contact Name & Phone: Coimments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City; State)
General Engineering Laboratories 2040 843 556Savage 8171.Road.
Attn.Charleston SC. 29407 0 <
Cheryl Jones Priority:-, 30.D. [114 D. E 7 D. El 3 D.
Container _ _ _ _ _ _ _ _ _ _ _ _
Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sarmple ID Code Code Code 9539-0001-011-F 01/03/07 1030 TS G BP X _,__ _..
9539-0001r012-F 01/03/07 1036 TS G BP X 9539-0001-013-F 01/03/07 1042 TS G BP X 9539-000h014-F 01/03/07 1048 TS G BP X 9539-0001-015-F 01/03/07 1052 TS G BP X I- e a -.-- - - - -r NOTES: PO #: 002332 MSR M-#6M SSWP# NA ' LTP QA E] Samples Shipped Via:
Radwaste QA El Non QA IifiternaicC,,tainr O-) -0o35'r [ Fed Ex Temp. Deg El UPS Cust~ o SeaId?
El Hand
- v2.:N 0.
- 1) Relinqfiished By Date/Tim Custody Seal El Other :itact?
- 3) Relinquished By Date/Time I I Bill of Lading #
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 200700005 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name:, Haddam Neck Decommissioning Analyses Requested Lab Use'Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City; State)
General EngineeringLaboratories 2040'Savage Road. Charleston SC. 29407 Q 843 556 8171. Attn. Cheryl Jones Priority: E] 30 D. F] 14D. Z 7 D. [1] 3 D.
Container Sample Designation Date Time Sample Size-Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9539-0001-016-1 01/05/07 0820 TS G BP X __,_".__...
9539-0001-017-1 01/05/07. 0.821 TS G BP X *_,_..
NOTES: PO #: 002332 MSR #: 94-ltr SSWP# NA Z LTP QA E] Radwaste QA El Non QA Samples Shipped Via: InternalContainer 07-i 66~-r [D Fed Ex T~hmp.: , Deg.
F1 uPs ." C El Hand Ciustody Sealed?
- 1) Relinquished By Date/Time 2) R* ved By Date/Time Custody Seal 1/11/')-7 c;30 E] Other Intact?
- 3) Relinquished By Date/Time IDate/Time -Y*('ND
- 4) Igei-ved By Bill of Lading #
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No, 2007-00011 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State),
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 81,71. Attn. Cheryl Jones V)
Priority: -- 30 D.E] 14 D. Z7 D. E- 3 D.
Container Sample Size-Sample Designation Date 0 Media Type &Type Comment, Preservation Lab Sample 11 Code Code Code 9539-0001-018-I 01/09/07 1010 TS G BP X 9539-0001-019-I 01/09/07 1012 TS G BP X 9539-0001-020-1 01/09/07 1020 TS G BP X 9539-0001-021-1 01/09/07 13.25 TS G BP X NOTES: PO#: 002332 MSR #.: SSWP# NA 0 LTP QA El Radwaste QA F1 Non QA Samples Shipped Via: Internal Container 07-oo&V Z Fed Ex. Temp.: _ý5 Deg.
El UPS C El Hand Custody Sealed?
Y 2( N 11
- 1) Relinquished By Date/Time 2) Re ived By Date/Time Custody Seal El Other Intact?
- 3) Relinquished By Date/Time 4) R ived.By / Dte/Time Yi NO Bill of Lading #
Connecticut Yankee Statementof Work for Analytical Lab Services *CY-lsc-SOW-OO1 Figure 1. Sample Check-in List Date/Time Received:- 0 7
&1 -~i~:!~7 SDG#: _ __ __ __ _ f K
Work Order Number:_ I 7, .) , ) _r" h "-
Shipping Cdntainer ID: C,c C.,. J'A-,.I '-P Chain of Custody,# ' . cwv4-f
I. Custody Seals off shipping containe r intact?. .Yes q No f j
- 2. Custody Seals dated and signed? Yes'[4 No [.
- 3. Chain-of-Custody record present? Yes (4 No I
- 4. Cooler temperature 19
- 5. Vermiculite/packing materials is: Wet [ ] Dry 6: Number of samples in shipping cont L4 Li - I
- 7. Sample holding times exceeded? Yes [ ] No f.1
.8. Samples have:'
.. 2sujapehazard labels
-custodyz.eals ZX ap.propriate sample labels
- 9. Samples are:
-~i~n good condition c__laking.
-broken _____have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [ ] No ,[l
.. .Description of anomalies (include sample numbers):
Sample Custodian/Laboratory: 2, y I Date.., - -7
.*.[
Telephoned to:- . On By (3-i; ) ,.2 10
-, r SAMPLEARECEIPT & REVIEW FORM
,. " ...... PM use only Client: SDG/ARCOCfWork Order:
Date Received: JPM(A) Review (ensur non-conforming Items arexresolved prior to si g Received B : ,y:.* ,-
Sample Receipt Crifkia : Comments/Qualifiers (Required for'Non. ntormingItems) pgand ~tinrsealed!
'intact" eevd....dmgd, otie/
Circle Applicable: seals broken damaged conta/ king container omaro~ d~l*
other (describe) 1 Shipping containers received Samples requiring cold, Circle Coolant # ice bags blue ip dry ice none other describe) 2 preservation within (4 +/- 2 C)?
Record preservation method: __.
Chain of custody documents included with shiment? \
4Sample containers .intact and CircleApp'lca'ble:. sbroken damaged container. leking container other (describe) sealed? _
Samples requiring chemical Sample ID's,"ntainers affected and observed pH:
preservation at proper pH? _.-_ _ __"
6 VOA vials free6Lof headspace SampJlOD's and con'tiners affected:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to
-VOA laboratory)
Samples received within holding Id's and tests affected 8time?\
Sample ID's on COC match ID's/ :Sample ID's and containers affected:
on bottles?
Date & time on COC matc/date Sample. ID's affectd
& time on bottles?_._
Number of containerdeceived Sample.ID's affected:
- match number inditated on COC?
COC form iss& I si***ed in reljnguishe~dreceived sections?
Air Bill ,Tracking #'s, &
14 Ay/ dditional Comments T RSO RAD Receipt #_____ _______
,. *If-> x2 area background is observed on samples identified as "non-Suspected Hazard Information ' *1 z -e 'regulated/non-radioactive", contact the Radiation Safety group for further C C9 investigation.
A IRadiologica! Classification? ,- I IMaximum Counts Observed*: Z C, (4'
-'0 B rPCB Regulated? 1<
JShipped as DO I Hazardousr C IMaterial? If yes, contact Waste lazard Class Shipped:
,Manager or ESH Manage JN#:
Regu ase a Foreign Soil? l PM (or PMA) review of Hazard classification:_ __ .. Initials 1//u/ :/Date:
- 1. -
13
SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM r
. i t -
Client: ~~f ~Date Received: '10)/ 0<
3:3
___ L~3~~Oooo
- L,7~, 7 2f&7 -0600)
- !-0( OGcoul I
12
Data Review Qualifier Definitions 13
Data Review Qualifier Definitions Qualifier Explanation
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound
- Result is less than value reported
> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.
GEL Laboratories LLC P0 Box 30712 Chaleston, SC 29417 2040 Savage Road Charlestn, SC 29407 P 843.555.8171 F 843.766.1178 www~gel.com 14
RADIOLOGICAL ANALYSIS 15
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 178924 Method/Analysis Information Product: Aiphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 601896 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-02I Batch Number: 601611 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260242 Method Blank (MB) 1201260243 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260244 178924001(9539-0001-001-F) Matrix Spike (MS) 1201260245 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
16
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 17
Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I1 -RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 601897 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-021 Batch Number: 601611 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260246 Method Blank (MB) 1201260247 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260248 178924001(9539-0001-001-F) Matrix Spike (MS) 1201260249 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
18
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201260247 (9539-0001-001-F) was recounted due to poor resolution.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I -RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 601898 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-021 Batch Number: 601611 19
Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260250 Method Blank (MB) 1201260251 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260252 178924001(9539-0001-001-F) Matrix Spike (MS) 1201260253 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples, 1201260250 (MB), 1201260251 (9539-0001-001-F), 1201260252 (9539-0001-001-F) and 178924001 (9539-0001-001-F), were recounted due to quench.
Miscellaneous Information:
NCR Documentation 20
Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300,4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 602157 Prep Batch Number: 601611 21
Sample ID Client ID 178924001 9539-0001-001-F 178924002 9539-0001-002-F 178924003 9539-0001-003-F 178924004 9539-0001-003-FS 178924005 9539-0001-004-F 178924006 9539-0001-005-F 178924007 9539-0001-006-F 178924008 9539-0001-007-F 178924009 9539-0001-008-F 178924010 9539-0001-009-F 178924011 9539-0001-010-F 178924012 9539-0001-011-F 178924013 9539-0001-012-F 178924014 9539-0001-013-F 178924015 9539-0001-014-F 178924016 9539-0001-015-F 178924017 9539-0001-016-I 178924018 9539-0001-017-1 178924019 9539-0001-018-1 178924020 9539-0001-019-I 1201260863 Method Blank (MB) 1201260864 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260865 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
I Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
22
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments The sample and the duplicate, 1201260864 (9539-0001-001-F) and 178924001 (9539-0001-001-F), for Cs-137 and Pb-214 did not meet the relative percent difference requirement, however they do meet the relative error ratio requirement with value of 1.24666 for Cs-137 and 2.25234 for Pb-214.
Qualifier information 23
Qualifier Reason Analyte Sample U' Data rejected due to high peak-width. Cesium-137 178924014 Lead-212 178924012 U' Data rejected due to interference. Europium- 155 178924019 UI Data rejected due to low abundance. Actinium-228 178924012 Cesium- 134 178924001 178924003 178924013 178924015 178924016 178924017 178924018 178924019 178924020 1201260864 Niobium-94 178924002 Silver- 108m 178924014 UI Data rejected due to no valid peak. Cesium- 134 178924014 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 602159 Prep Batch Number: 601628 24
Sample ID Client ID 178924021 9539-0001-020-I 178924022 9539-0001-021-I 1201260866 Method Blank (MB) 1201260867 178923021(9539-0002-020-1) Sample Duplicate (DUP) 1201260868 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178923021 (9539-0002-020-1).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this 25
SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance. Bismuth-214 1201260866 Cesium-134 178924021 178924022 1201260867 Lead-212 1201260866 Niobium-94 178924021 Potassium-40 1201260866 Radium-226 1201260866 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 601901 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-021 Batch Number: 601611 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260261 Method Blank (MB) 1201260262 178924001(9539-0001-001 -F) Sample Duplicate (DUP) 1201260263 178924001(9539-0001-00 1-F) Matrix Spike (MS) 1201260264 Laboratory Control Sample (LCS) 26
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001 -F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Sample 178923011 result is greater than the mda and tpu. Client gave permission to send.
27
Oualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 601908 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260283 Method Blank (MB) 1201260284 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260285 178924001(9539-0001-001 -F) Matrix Spike (MS) 1201260286 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
28
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample setrequired reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 602972 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-021 Batch Number: 601611 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201262579 Method Blank (MB) 1201262580 178924001(9539-0001-001 -F) Sample Duplicate (DUP) 1201262581 178924001(9539-0001-001 -F) Matrix Spike (MS) 1201262582 Laboratory Control Sample (LCS) 29
SOP Reference /
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery. Samples were reprepped due to low/high carrier/tracer yield. Samples were reprepped due to low/high recovery.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
30
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-I, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 601907 Prep Batch Number: 601632 Dry Soil Prep GL-RAD-A-021 Batch Number: 601611 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260279 Method Blank (MB) 1201260280 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260281 178924001(9539-0001-001-F) Matrix Spike (MS) 1201260282 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
31
Designated QC The following sample was used for QC: 178924001 (9539-0001-00 1-F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 601909 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260287 Method Blank (MB) 1201260288 178923010(9539-0002-009-F) Sample Duplicate (DUP) 1201260289 178923010(9539-0002-009-F) Matrix Spike (MS) 1201260290 Laboratory Control Sample (LCS) 32
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178923010 (9539-0002-009-F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201260290 (LCS) was recounted due to analyst transcription error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
33
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint C14, Solid All,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 601910 Sample ID Client ID 178924001 9539-0001-001-F 178924008 9539-0001-007-F 1201260291 Method Blank (MB) 1201260292 178924001(9539-0001-001-F) Sample Duplicate (DUP) 1201260293 178924001(9539-0001-00 1-F) Matrix Spike (MS)
.1201260294 Laboratory, Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).
QC Information All of the QC samples met the required acceptance limits.
34
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201260293 (9539-0001-001-F) was recounted due to spectral interference.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date: - "I", 1)1 7 35
-I, SAMPLE DATA
SUMMARY
36
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.
Client SDG: MSR#07-0035 GEL Work Order: 178924 The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 37
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-001-F Proiect: YANK01204 Sample ID: 178924001 Client ID: YANKOOl Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 13.5%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt4 Rad Alpha Spec Analysis Alphaspec Am241, Cm, SolidALL FSS Americium-241 IJ 0.00849 +/-0.111 0.089 +/-0.111 0.273 pCi/g MXA 01/12/07 1919 601896 1 1
Curium-242 U -0.0527 +/-0.0421 0.0804 +/-0.0426 0.260 pCi/g Curium-243/244 U 0.0126 +/-0.131 0.104 +/-0.131 0.304 pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.00119 +/-0.0649 0.0536 +/-0.0649 0.188 pCi/g MXA 01/12/07 1614 601897 2 1
Plutonium-239/240 U -0.0358 +/-0.0314 0.0599 +/-0.0317 0.201 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -9.26 +/-9.39 8.27 +/-9.39 17.3 pCi/g MXA 01/16/07 0727 601898 3 1
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.659 +/-0.176 0.0651 +/-0.176 0.142 pCi/g MJHI 01/15/07 0701 602157 4 Americium-241 U 0.00967 +/-0.0287 0.0227 .+/-0.0287 0.0471 pCi/g Bismuth-212 0.628 +/-0.290 0.130 +/-0.290 0.283 pCi/g Bismuth-214 0.591 +/-0.0888 0.0316 +/-0.0888 0.0681 pCi/g Cesium-134 UI 0.00 +/-0.0458 0.0237 +/-0.0458 0.0508 pCi/g Cesium-137 0.167 +/-0.0556 0.0178 +/-0.0556 0.0384 pCi/g Cobalt-60 U -0.00235 +/-0.0253 0.0207 +/-0.0253 0.0461 pCi/g Europium-152 U -0.0256 +/-0.0525 0.0417 +/-0.0525 0.0885 pCi/g Europium-154 U -0.0453 +/-0.0805 0.0626 +/-0.0805 0.138 pCi/g Europium-155 U 0.029 +/-0.0416 0.0385 +/-0.0416 0.0802 pCi/g Lead-212 0.638 +/-0.058 0.0236 +/-0.058 0.0494 pCi/g Lead-214 0.715 +/-0.0987 0.0299 +/-0.0987 0.0635 pCi/g Manganese-54 U -0.00805 +/-0.0216 0.0169 +/-0.0216 0.037 pCi/g Niobium-94 U-0.000198 +/-0.0203 0.0169 +/-0.0203 0.0363 pCi/g Potassium-40 9.53 +/-0.860 0.171 +/-0.860 0.389 pCi/g Radium-226 0.591 +/-0.0888 0.0316 +/-0.0888 0.0681 pCi/g Silver-108m U 0.00819 +/-0.0187 0.0168 +/-0.0187 0.0357 pCi/g Thallium-208 0.216 +/-0.0502 0.0152 +/-0.0502 0.033 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00386 +/-0.0267 0.0222 +/-0.0267 0.0469 pCi/g KSDI 01/15/07 1802 601901 5 38
N GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-001-F Project: YANK01204 Sample ID: 178924001 Client ID: YANKOO 1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U 1.27 +/-1.37 1.07 +/-1.37 2.30 pCi/g MXPI 01/15/07 1500 601909 6 Liquid Scint C14, Solid AllFSS Carbon-14 U -0.00673 +/-0.119 0.0997 +/-0.119 0.203 pCi/g MXPI 01/15/07 1636 601910 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -17.2 +/-28.4 20.9 +/-28.4 44.3 pCi/g MXPI 01/18/07 0819 602972 8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.00 +/-9.32 7.82 +/-9.32 16.5 pCi/g KXRI 01/15/07 1035 601907 H(
LiquidScini Tc99, Solid-ALL FSS Technetium-99 0.387 +/-0.187 0.151 +/-0.188 0.308 pCi/g MXP1 01/17/07 1210 601908 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-1, Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-1, Modified 11 DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 91 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 84 (15%-125%)
Plutonium-241 Liquid Scint Pu241, Solid-ALL FS 83 (25%-125%)
39
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-001-F Proiect: YANK01204 Sample ID: 178924001 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU, MDA Units DF Analyst Date Time Batch Mt Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 83 (25%-125%)
Strontium-90 GFPC, Sr90, solid-ALL FSS 86 (25%-125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 86 (25%-1 25%)
Nickel-63 Liquid Scint Ni63, Solid-ALL FS 82 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 82 (25%-125%)
Technetium-99 Liquid Scint Tc99, Solid-ALL FS 77 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
40
.GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
- Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-002-F Proiect: YANKO 1204 Sample ID: 178924002 Client ID: YANKOO I Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 5.95%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.381 +/-0.160 0.0558 +/-0.160 0.124 pCi/g MJH1I 01/15/07 0701 602157 1 Americium-241 U -0.0033 -+/-0.0246 0.0207 +/-0.0246 0.0433 pCi/g Bismuth-212 U 0.266 +/-0.283 0.129 +/-0.283 0.282 pCi/g Bismuth-214 0.328 k/-0.0788 0.0336 +/-0.0788 0.0721 pCi/g Cesium-134 U 0.0438 k/-0.0328 0.0238 +/-0.0328 0.051 pCi/g Cesium-137 U -0.00212 -k/-0.0216 0.0192 +/-0.0216 0.0413 pCi/g Cobalt-60 U -0.00886 k/-0.0297 0.0201 +/-0:0297 0.0448 pCi/g Europium-152 U -0.00729 -k/-0.0473 0.0415 +/-0.0473 0.0882 pCi/g Europium-154 U 0.0406 k/-0.0594 0.0546 +/-0.0594 0.122 pCi/g Europium-155 U 0.022 -k/-0.0562 0.0354 +/-0.0562 0.074 pCi/g Lead-212 0.284 k/-0.0507 0.0242 +/-0.0507 0.0508 pCi/g Lead-214 0.343 k/-0.0753 0.0287 +/-0.0753 0.0612 pCi/g Manganese-54 U 0.0138 P/-0.0215 0.0132 +/-0.0215 0.0296 pCi/g Niobium-94 UI 0.00 +/-0.0455 0.0187 +/-0.0455 0.040 pCi/g Potassium-40 7.18 +/-0.811 0.155 +/-0.811 0.356 pCi/g Radium-226 0.328 +/-0.0788 0.0336 +/-0.0788 0.0721 pCi/g Silver- 108m U 0.012 +/-0.0168 0.0155 +/-0.0168 0.0331 pCi/g Thallium-208 0.130 +/-0.0374 0.0156 +/-0.0374 0.0339 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 41
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-002-F Project: YANK01204 Sample ID: 178924002 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
42
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-003-F Project: YANK01204 Sample ID: 178924003 Client ID: YANKOO I Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 21.5%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.671 +/- -0.140 0.044 +/-0.140 0.0879 pCi/g MJHI 01/15/070733 602157 1 Americium-241 U 0.0319 +/- -0.106 0.0835 +/-0.106 0.167 pCi/g Bismuth-212 0.378 +/- +/-0.170 0.194
-0.170 0.0969 pCi/g Bismuth-214 0.608 +/-0.0889 0.0255 +/-0.0889 0.0509 pCi/g Cesium- 134 Ul 0.00 +/-0.0192 0.0158 +/-0.0192 0.0315 pCi/g Cesium- 137 0.174 +/-0.0313 0.0134 +/-0.0313 0.0267 pCi/g Cobalt-60 U -0.00443 +/-0.0173 0.0141 +/-0.0173 0.0281 pCi/g Europium- 152 U 0.00312 +/-0.047 0.037 +/-0.047 0.074 pCi/g Europium- 154 U 0.00961 +/-0.0452 0.0382 +/-0.0452 0.0763 pCi/g Europium- 155 U 0.0261 +/-0.0578 0.047 +/-0.0578 0.094 pCi/g Lead-212 0.699 +/-0.0715 0.0211 +/-0.0715 0.0421 pCi/g Lead-214 0.604 +/-0.0791 0.0251 +/-0.0791 0.0501 pCi/g Manganese-54 U 0.0163 +/-0.0213 0.0133 +/-0.0213 0.0266 pCi/g Niobium-94 U -0.00776 +/-0.015 0.012 +/-0.015 0.024 pCi/g Potassium-40 12.1 +/-0.927 0.123 +/-0.927 0.246 pCi/g Radium-226 0.608 +/-0.0889 0.0255 +/-0.0889 0.0509 pCi/g Silver-108m U 0.000681 +/-0.0138 0.0118 +/-0.0138 0.0235 pCi/g Thallium-208 0.215 +/-0.0369 0.0124 +/-0.0369 0.0247 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 43
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007,
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-003-F Proiect: YANK01204 Sample ID: 178924003 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
44
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-003-FS Project: YANK01204 Sample ID: 178924004 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 21.3%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.698 +/-0.181 0.0593 +/-0.181 0.129 pCi/g MT1I1 01/15/07 0756 602157 1 Americium-241 U 0.0734 +/-0.0863 0.045 +/-0.0863 0.0935 pCi/g Bismuth-212 U 0.249 +/-0.230 0.163 +/-0.230 0.345 pCi/g Bismuth-214 0.488 +/-0.0947 0.0352 +/-0.0947 0.0747 pCi/g Cesium- 134 U 0.0446 +/-0.033 0.0237 +/-0.033 0.0504 pCi/g Cesium-137 0.148 +/-0.0467 0.017 +/-0.0467 0.0366 pCi/g Cobalt-60 U 0.0169 +/-0.0225 0.0202 +/-0.0225 0.0445 pCi/g Europium-152 U -0.023 +/-0.0567 0.0466 +/-0.0567 0.0981 pCi/g Europium-154 U -0.0197 +/-0.0542 0.0417 +/-0.0542 0.0943 pCi/g Europium-155 U 0.0197 +1-0.0515 0.0473 +/-0.0515 0.0981 pCi/g Lead-212 0.710 +/-0.0839 0.0258 +/-0.0839 0.0539 pCi/g Lead-214 0.642 +/-0.104 0.0325 +/-0.104 0.0686 pCi/g Manganese-54 U 0.0023 +/-0.0209 0.0179 +/-0.0209 0.0386 pCi/g Niobium-94 U -0.00504 +/-0.0205 0.0173 +/-0.0205 0.037 pCi/g Potassium-40 11.1 +/- 1.11 0.168 +/-1.11 0.376 pCi/g Radium-226 0.488 +/-0.0947 0.0352 +/-0.0947 0.0747 pCi/g Silver-108m U 0.00319 +/-0.0197 0.0166 +/-0.0197 0.0351 pCi/g Thallium-208 0.220 +/-0.0531 0.0159 +1-0.0531 0.0341 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 45
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-003-FS Proiect: YANKO 1204 Sample ID: 178924004 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt,
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UL Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
46
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-004-F Proiect: YANK01204 Sample ID: 178924005 Client ID: YANKOO1 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 6.72%
Parameter Qualifier Result Uncertainty LC TPU MDA Units. DF Analyst Date Time Batch Mti Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.389 +/-0.127 0.0428 +/-0.127 0.0962 pCi/g MJH1 01/15/07 1030 602157 1 Americium-241 U -0.0104 +/-0.0652 0.0547 +/-0.0652 0.115 pCi/g Bismuth-212 U 0.211 +/-0.154 0.137 +/-0.154 0.294 pCi/g Bismuth-214 0.301 +/-0.0748 0.025 +/-0.0748 0.0543 pCi/g Cesium-134 U 0.0167 +/-0.0184 0.0172 +/-0.0184 0.0375 pCi/g Cesium-137 0.0366 +/-0.019 0.0133 +/-0.019 0.0292 pCi/g Cobalt-60 U 0.0281 +/-0.0194 0.0198 +/-0.0194 0.0436 pCi/g Europium-152 U -0.0242 +/-0.0415 0.0332 +/-0.0415 0.0713 pCi/g Europium-154 U -0.0144 +/-0.0508 0.0355 +/-0.0508 0.0821 pCi/g Europium-155 U -0.0142 +/-0.0431 0.0387 +/-0.0431 0.081 pCi/g Lead-212 0.360 +/-0.0593 0.0207 +/-0.0593 0.0435 pCi/g Lead-214 0.308 +/-0.0745 0.0236 +/-0.0745 0.0507 pCi/g Manganese-54 U -0.0043 +/-0.0162 0.0133 +/-0.0162 0.0294 pCi/g Niobium-94 U 0.0133 +/-0.0155 0.0144 +/-0.0155 0.0312 pCi/g Potassium-40 5.52 +/-0.797 0.122 +/-0.797 0.285 pCi/g Radium-226 0.301 +/-0.0748 0.025 +/-0.0748 0.0543 pCi/g Silver-108m- U -0.0124 +/-0.0147 0.0122 +/-0.0147 0.0263 pCi/g Thallium-208 0.136 +/-0.0354 0.0136 +/-0.0354 0.0296 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 47
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-004-F Proiect: YANK01204 Sample ID: 178924005 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ut Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
48
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-005-F Proiect: YANKO 1204 Sample ID: 178924006 Client ID: YANK001 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 1 I-JAN-07 Collector: Client Moisture: 4.66%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowih Waived Actinium-228 0.229 +/-0.0949 0.0415 +/-0.0949 0.0918 pCi/g MJH1 01/15/07 1031 602157 1 Americium-24 I U-0.000887 +/-0.0684 0.0578 +/-0.0684 0.121 pCi/g Bismuth-212 0.322 +/-0.233 0.0917 +/-0.233 0.200 pCi/g Bismuth-214 0.196 +/-0.0593 0.0244 +/-0.0593 0.0524 pCi/g Cesium- 134 U 0.00365 +/-0.0153 0.0135 +/-0.0153 0.0295 pCi/g Cesium- 137 U -0.00346 +/-0.0137 0.0117 +/-0.0137 0.0254 pCi/g pCi/g Cobalt-60 U 0.00964 +/-0.0441 0.0118 +/-0.0441 0.0269 Europium- 152 U 0.0585 +/-0.0361 0.0333 +/-0.0361 0.0709 pCi/g Europium- 154 U -0.0396 +/-0.0443 0.0327 +/-0.0443 0.0747 pCi/g Europium- 155 U 0.0132 +/-0.038 0.0375 +/-0.038 0.0783 pCi/g Lead-212 0.303 +/-0.0393 0.0172 +/-0.0393 0.0364 pCi/g Lead-214 0.260, +/-0.0615 0.0216 -+/-0.0615 0.0462 pCi/g Manganese-54 U 0.0144 +/-0.0156 0.0146 +/-0.0156 0.0315 pCi/g Niobium-94 U 0.00389 +/-0.0123 0.0111 +/-0.0123 0.024 pCi/g Potassium-40 4.48 +/-0.542 0.120 +/-0.542 0.274 pCi/g Radium-226 0.196 +/-0.0593 0.0244 +/-0.0593 0.0524 pCi/g Silver- 108m U -0.00461 +/-0.012 0.0107 +/-0.012 0.023 pCi/g Thallium-208 0.0609 +/-0.0321 0.0122 +/-0.0321 0.0264 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 49
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-005-F Project: YANK01204 Sample ID: 178924006 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
50
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-006-F Proiect: YANKO 1204 Sample ID: 178924007 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 5.19%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis GammaSolid-FSS GAM& ALL FSS 226 Ingrowth Waived Actinium-228 0.253 +/-0.0818 0.0404 +/-0.0818 0.0858 pCi/g MJH1 01/15/07 1033 602157 1 Americium-241 U 0.0537 +/-0.0684 0.0572 +/-0.0684 0.118 pCi/g 1 Bismuth-212 0.293 +/-0.129 0.0771 +/-0.129 0.164 pCi/g Bismuth-214 0.222 +/-0.0524 0.0174 +/-0.0524 0.037 pCi/g Cesium- 134 U 0.018 +/-0.0173 0.0122 +/-0.0173 0.0258 pCi/g Cesium-137 U-0.000305 +/-0.011 0.00941 +/-0.011 0.0201 pCi/g Cobalt-60 U 0.00413 +/-0.0118 0.0104 +/-0.0118 0.0227 pCi/g Europium-152 U -0.00823 +/-0.0307 0.0256 +/-0.0307 0.0535 pCi/g Europium- 154 U 0.0584 +/-0.0582 0.0319 +/-0.0582 0.0691 pCi/g Europium-155 U 0.0186 +/-0.0313 0.0297 +/-0.0313 0.0613 pCi/g Lead-212 0.289 +/-0.0355 0.0158 +/-0.0355 0.0328 pCi/g Lead-214 0.305 +/-0.0509 0.0177 +/-0.0509 0.0371 pCi/g Manganese-54 U 0.00349 +/-0.0118 0.0101 +/-0.0118 0.0216 pCi/g Niobium-94 U 0.00352 +/-0.0102 0.00895 +/-0.0102 0.019 pCi/g Potassium-40 4.81 +/-0.426 0.083 +/-0.426 0.186 pCi/g Radium-226 0.222 +/-0.0524 0.0174 +/-0.0524 0.037 pCi/g Silver- 108m U-0.000894 +/-0.00925 0.00819 +/-0.00925 0.0173 pCi/g Thallium-208 0.0991 +/-0.0253 0.00888 +/-0.0253 0.0189 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 51
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-006-F Project: YANKO 1204 Sample ID: 178924007 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
52
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-007-F Project: YANK01204 Sample ID: 178924008 Client ID: YANK001 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 6.8%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0704 +/-0.101 0.119 +/-0.101 0.337 pCi/g MXA 01/12/07 1919 601896 1
Curium-242 U 0.00153 +/-0.0833 0.0687 +/-0.0833 0.241 pCi/g Curium-243/244 U -0.0765 +/-0.124 0.136 +/-0.125 0.372 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0285 +/-0.0645 0.0533 +/-0.0645 0.187 pCi/g MXA 01/12/07 1614 601897 2 A
Plutonium-239/240 U -0.0415 +/-0.073 0.0842 +/-0.0732 0.249 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 2.28 +/-7.86 6.50 +/-7.87 13.6 pCi/g MXA 01/15/07 2338 601898 3 I
Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.490 +/-0.147 0.0602 +/-0.147 0.132 pCi/g MJH1 01/15/07 1033 602157 4 Americium-241 U 0.017 +/-0.0281 0.024 +/-0.0281 0.0497 pCi/g Bismuth-212 0.524 +/-0.238 0.159 +/-0.238 0.341 pCi/g Bismuth-214 0.402 +/-0.0977 0.0332 +/-0.0977 0.0714 pCi/g Cesium- 134 U 0.0469 +/-0.048 0.0224 +/-0.048 0.0482 pCi/g Cesium-137 0.0579 +/-0.0508 0.0178 +/-0.0508 0.0385 pCi/g Cobalt-60 U 0.0176 +/-0.0218 0.0205 +/-0.0218 0.0456 pCi/g Europium-152 U -0.011 +/-0.049 0.0431 +/-0.049 0.0915 pCi/g Europium-154 U 0.0257 +/-0.0552 0.0502 +/-0.0552 0.113 pCi/g Europium-155 U 0.0465 +/-0.0512 0.0402 +/-0.0512 0.0836 pCi/g Lead-212 0.447 +/-0.0674 0.0297 +/-0.0674 0.0618 pCi/g Lead-214 0.453 +/-0.0822 0.0311 +/-0.0822 0.066 pCi/g Manganese-54 U -0.00124 +/-0.0222 0.0184 +/-0.0222 0.040 pCi/g Niobium-94 U -0.00812 +/-0.0207 0.0168 +/-0.0207 0.0363 pCi/g Potassium-40 8.72 +/-0.786 0.144 +/-0.786 0.333 pCi/g Radium-226 0.402 +/-0.0977 0.0332 +/-0.0977 0.0714 pCi/g Silver-108m U 0.0151 +/-0.0182 0.017 +/-0.0182 0.036 pCi/g Thallium-208 0.180 +/-0.0417 0.0171 +/-0.0417 0.0368 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0138 +/-0.0257 0.0223 +/-0.0257 0.0473 pCi/g KSDI 01/15/07 1802 601901 5 Rad Liquid Scintillation Analysis 53
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-007-F Proiect: YANK01204 Sample ID: 178924008 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U 0.705 +/-1.34 1.08 +/-1.34 2.32 pCi/g MXPI 01/15/07 1531 601909 6 Liquid Scin C14, SolidAIlFSS Carbon-14 U -0.0725 +1-0.115 0.0975 +/-0.115 0.199 pCi/g MXPI 01/15/07 1740 601910 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -27.2 +/-24.6 18.6 +/-24.6 39.5 pCi/g MXPI 01/18/07 0835 602972 8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -0.273 +/-8.82 7.42 +/-8.82 15.6 pCi/g KXRI 01/15/07 1052 601907 1(
Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0745 +/-0.174 0.145 +/-0.174 0.295 pCi/g MXPI 01/17/07 1257 601908 1]
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I DOE EML HASL-300,.Am-05-RC Modified 2 DOE EML HASL-300, Pu- 1I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-1, Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified II DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-24.J Alpnaspec Am24 1, Cm, Solid ALL (15%o-125o)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 81 (15%-125%)
Plutonium-241 Liquid Scint Pu241, Solid-ALL FS 97 (25%-125%)
54
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-007-F Project: YANK01204 Sample ID: 178924008 Client ID: YANKOO 1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 97 (25%-125%)
Strontium-90 GFPC, Sr90, solid-ALL FSS 79 (25%-125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)
Nickel-63 Liquid Scint Ni63, Solid-ALL FS 89 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 89 (25%-125%)
Technetium-99 Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
55
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-008-F Project: YANK01204 Sample ID: 178924009 Client ID: YANKOO I Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 1 I-JAN-07 Collector: Client Moisture: 19.5%
Parameter :ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.227 0.062 +/-0.227 0.135 pCi/g MJHI 01/15/07 1034 602157 1 Americium-241 U 0.044 +/-0.116 0.0918 +/-0.116 0.190 pCi/g Bismuth-212 0.449 +/-0.374 0.135 +/-0.374 0.291 pCi/g Bismuth-214 1.04 +/-0.162 0.0355 +/-0.162 0.0757 pCi/g Cesium-134 U 0.0554 +/-0.0476 0.0273 +/-0.0476 0.0578 pCi/g Cesium-137 0.134 +/-0.0524 0.0223 +/-0.0524 0.0474 pCi/g Cobalt-60 U 0.0165 +/-0.025 0.0224 +/-0.025 0.0491 pCi/g Europium-I 52 U -0.00372 +/-0.0603 0.0534 +/-0.0603 0.112 pCi/g Europium- 154 U -0.062 +/-0.0734 0.0544 +/-0.0734 0.121 pCi/g Europium- 155 U 0.0698 +/-0.0656 0.0613 +/-0.0656 0.127 pCi/g Lead-212 0.997 +/-0.103 0.0265 +/-0.103 0.0552 pCi/g Lead-214 1.08 +/-0.142 0.0371 +/-0.142 0.0778 pCi/g Manganese-54 U 0.00444 +/-0.0232 0.0204 +/-0.0232 0.0438 pCi/g Niobium-94 U -0.00299 +/-0.0249 0.0179 +/-0.0249 0.0383 pCi/g Potassium-40 10.8 +/-1.13 0.144 +/-I.13 0.331 pCi/g Radium-226 1.04 +/-0.162 0.0355 +/-0.162 0.0757 pCi/g Silver- 108m U 0.00519 +/-0.0194 0.0172 +/-0.0194 0.0364 pCi/g Thallium-208 0.344 +/-0.0618 0.0182 +/-0.0618 0.039 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 56
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-008-F Proiect: YANK01204 Sample ID: 178924009 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
57
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-009-F Proiect: YANK01204 Sample ID: 178924010 Client ID: YANKOO 1 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 5.39%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.349 +/-0.132 0.0449 +/-0.132 0.0984 pCi/g MJHI 01/15/07 1034 602157 1 Americium-241 U 0.00885 +/-0.0613 0.0588 +/-0.0613 0.122 pCi/g Bismuth-212 0.278 +/-0.153 0.102 +/-0.153 0.220 pCi/g Bismuth-214 0.349 +/-0.0714 0.0264 +/-0.0714 0.0565 pCi/g Cesium-134 U 0.0216 +/-0.0184 0.0172 +/-0.0184 0.0369 pCi/g Cesium-137 0.0971 +/-0.0369 0.0132 +/-0.0369 0.0285 pCi/g Cobalt-60 0.0459 +/-0.0299 0.0137 +/-0.0299 0.0306 pCi/g Europium- 152 U 0.0147 +/-0.0377 0.035 +/-0.0377 0.0741 pCi/g Europium-154 U 0.0207 +/-0.0525 0.0465 +/-0.0525 0.102 pCi/g Europium-155 U 0.00741 +/-0.0414 0.0385 +/-0.0414 0.0802 pCi/g Lead-212 0.330 +/-0.067 0.0254 +/-0.067 0.0528 pCi/g Lead-214 0.327 +/-0.0846 0.0231 +/-0.0846 0.0492 pCi/g Manganese-54 U -0.00955 +/-0.016 0.0134 +/-0.016 0.029 pCi/g Niobium-94 U -0.00179 +1-0.0151 0.0127 +/-0.0151 0.0272. pCi/g Potassium-40 6.55 +/-0.789 0.135 +/-0.789 0.304 pCi/g Radium-226 0.349 +/-0.0714 0.0264 +/-0.0714 0.0565 pCi/g Silver-108m U 0.00272 +/-0.014 0.0126 +/-0.014 0.0269 pCi/g Thallium-208 0.123 +/-0.0324 0.0144 +/-0.0324 0.0308 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 58
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-009-F Project: YANK01204 Sample ID: 178924010 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Wt4
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
59
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 -*(843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-010-F Project: YANK01204 Sample ID: 178924011 Client ID: YANKOOl Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 7.31%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.472 +/-0.107 0.0263 +/-0.107 0.0559 pCi/g MJHI 01/15/07 1725 602157 1 Americium-241 U 0.0198 +/-0.0375 0.0336 +/-0.0375 0.0689 pCi/g Bismuth-212 0.241 +/-0.111 0.061 +/-0.111 0.128 pCi/g Bismuth-214 0.336 +/-0.0569 0.0157 +/-0.0569 0.0328 pCi/g Cesium-134 U 0.00884 +/-0.014 0.00932 +/-0.014 0.0196 pCi/g Cesium-137 0.0376 +/-0.0159 0.00752 +/-0.0159 0.0158 pCi/g Cobalt-60 U 0.00425 +/-0.00997 0.00895 +/-0.00997 0.0192 pCi/g Europium- 152 U -0.00729 +/-0.0242 0.0207 +/-0.0242 0.0429 pCi/g Europium-154 U -0.0187 +/-0.0291 0.024 +/-0.0291 0.0514 pCi/g Europium-155 U 0.0155 +/-0.031 0.0229 +/-0.031 0.0469 pCi/g Lead-212 0.412 +/-0.0447 0.012 +/-0.0447 0.0247 pCi/g Lead-214 0.317 +/-0.0503 0.0149 +/-0.0503 0.0308 pCi/g Manganese-54 U 0.00105 +/-0.00944 0.00818 +/-0.00944 0.0172 pCi/g Niobium-94 U -0.00317 +/-0.00806 0.00689 +/-0.00806 0.0145 pCi/g Potassium-40 8.36 +/-0.730 0.0779 +/-0.730 0.169 pCi/g Radium-226 0.336 +/-0.0569 0.0157 +/-0.0569 0.0328 pCi/g Silver-108m U 0.00204 +/-0.00743 0.00688 +/-0.00743 0.0143 pCi/g Thallium-208 0.128 +/-0.0252 0.00731 +/-0.0252 0.0154 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1031 601611 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria 60
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-010-F Proiect: YANK01204 Sample ID: 178924011 Client ID: YANK00I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MtW
- Analyte is a surrogate compound
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
61
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-011-F Proiect: YANK01204 Sample ID: 178924012 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 4.74%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowlt Waived Actinium-228 UI 0.00 +/-0.182 0.124 +/-0.182 0.259 pCi/g MJHI 01/15/07 1035 602157 1 Americium-24 I U -0.16 +/-0.0842 0.0566 +/-0.0842 0.117 pCi/g Bismuth-212 0.377 +/-0.234 0.141 +/-0.234 0.303 pCi/g Bismuth-214 0.332 +/-0.110 0.0347 +/-0.110 0.0738 pCi/g Cesium- 134 U 0.0193 +/-0.0234 0.0209 +/-0.0234 0.045 pCi/g Cesium- 137 U -0.00403 +/-0.0211 0.0174 +/-0.0211 0.0373 pCi/g Cobalt-60 U -0.0163 +/-0.023 0.0176 +/-0.023 0.0393 pCi/g Europium- 152 U 0.0078 +/-0.0921 0.0471 +/-0.0921 0.0993 pCi/g Europium- 154 U 0.0358 +/-0.0649 0.0584 +/-0.0649 0.128 pCi/g Europium- 155, U 0.00925 +/-0.0562 0.0484 +/-0.0562 0.100 pCi/g Lead-212 UI 0.00 +/-0.0954 0.0269 +/-0.0954 0.0562 pCi/g Lead-214 0.430 +/-0.109 0.0366 +/-0.109 0.077 pCi/g Manganese-54 U 0.000397 +/-0.0227 0.0188 +/-0.0227 0.0405 pCi/g Niobium-94 U 0.00974 +/-0.0214 0.0185 +/-0.0214 0.0393 pCi/g Potassium-40 8.86 +/-1.07 0.130 +/-1.07 0.302 pCi/g Radium-226 0.332 +/-0.110 0.0347 +/-0.110 0.0738 pCi/g Silver- 108m U -0.00431 +/-0.019 0.016 +/-0.019 0.034 pCi/g Thallium-208 0.132 +/-0.0427 0.0187 +/-0.0427 0.0398 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 62
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-011-F Project: YANK01204 Sample ID: 178924012 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt4
< Result is less than value reported
, Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager conceming this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
63
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-012-F Proiect: YANK01204 Sample ID: 178924013 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 24.1%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04 +/-0.149 0.0567 +/-0.149 0.120 pCi/g MJH1 01/15/07 1036 602157 Americium-241 U 0.043 +/-0.0966 0.0779 +/-0.0966 0.159 pCi/g Bismuth-212 0.829 +/-0.302 0.127 +/-0.302 0.268 pCi/g Bismuth-214 0.892 +/-0.0931 0.0287 +/-0.0931 0.0603 pCi/g Cesium- 134 UI 0.00 +/-0.0367 0.0231 +/-0.0367 0.0482 pCi/g Cesium- 137 0.234 +/-0.0405 0.0185 +/-0.0405 0.0386 pCi/g Cobalt-60 U -0.00433 +/-0.021 0.0169 +/-0.021 0.0364 pCi/g Europium-152 U -0.0327 +/-0.0553 0.0452 +/-0.0553 0.0936 pCi/g Europium-154 U -0.0046 +/-0.0622 0.0509 +/-0.0622 0.109 pCi/g Europium- 155 U 0.0247 +/-0.0601 0.0536 +/-0.0601 0.110 pCi/g Lead-212 1.10 +/-0.0612 0.0268 +/-0.0612 0.0551 pCi/g Lead-214 1.07 +/-0.0974 0.0333 +/-0.0974 0.0688 pCi/g Manganese-54 U 0.014 +/-0.0198 0.0175 +/-0.0198 0.0368 pCi/g Niobium-94 U 0.00212 +/-0.0183 0.0157 +/-0.0183 0.0329 pCi/g Potassium-40 12.7 +/-0.807 0.121 +/-0.807 0.269 pCi/g Radium-226 0.892 +/-0.0931 0.0287 +/-0.0931 0.0603 pCi/g Silver-108m U 0.0109 +/-0.0187 0.016 +/-0.0187 0.0332 pCi/g Thallium-208 0.353 +/-0.0417 0.0189 +/-0.0417 0.0394 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1039 601628 The following Analytical Methods were performed Method Description EML I-ASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 64
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-012-F Proiect: YANKO 1204 Sample ID: 178924013 Client ID: YANKOOI Vol. Recv.: /
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
65
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-013-F Project: YANK01204 Sample ID: 178924014 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 4.14%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.684 +/-0.210 0.0731 +/-0.210 0.157 pCi/g MJHI 01/15/07 1036 602157 1 Americium-241 U 0.027 -+/-0.0345 0.0315 +/-0.0345 0.0648 pCi/g Bismuth-212 U 0.250 +/-0.308 0.199 +/-0.308 0.421 pCi/g Bismuth-214 0.673 +/-0.121 0.044 +/-0.121 0.0927 pCi/g Cesium-134 UI 0.00 -+/-0.0502 0.0246 +/-0.0502 0.0524 pCi/g Cesium-137 Ul 0.00 -+/-0.0623 0.0243 +/-0.0623 0.0513 pCi/g Cobalt-60 U 0.0051 -+/-0.0299 0.0254 +/-0.0299 0.0551 pCi/g Europium-152 U -0.0311 - /-0.0632 0.052 +/-0.0632 0.109 pCi/g Europium-154 U -0.0352 P/-0.0847 0.0683 +/-0.0847 0.148 pCi/g Europium-155 U 0.0277 -+/-0.0596 0.0516 +/-0.0596 0.107 pCi/g Lead-212 0.600 -q
+/-0.0768 0.0415 +/-0.0768 0.0852 pCi/g
-q Lead-214 0.566 P/-0.0925 0.0438 +/-0.0925 0.0912 pCi/g Manganese-54 U 0.00562 +/-0.0282 0.0239 +/-0.0282 0.0507 pCi/g Niobium-94 U 0.0334 k/-0.0416 0.0238 +/-0.0416 0.050 pCi/g Potassium-40 12.0 +/-0.928 0.199 +/-0.928 0.441 pCi/g Radium-226 0.673 +/-0.121 0.044 +/-0.121 0.0927 pCi/g
-q Silver- 108m UI 0.00 k/-0.0317 0.0186 +/-0.0317 0.0392 pCi/g Thallium-208 0.277 k/-0.0526 0.024 +/-0.0526 0.0505 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 66
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-013-F Proiect: YANK01204 Sample ID: 178924014 Client Vol. Recv.: YANK001 ID:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc
< Result is less than value reported
> Result is greater than value, reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample>
H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager conceming this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
67
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-014-F Proiect: YANK01204 Sample ID: 178924015 Client ID: YANKOO1 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: I1-JAN-07 Collector: Client Moisture: 20.2%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.33 +/-0.233 0.0644 +/-0.233 0.140 pCi/g MJHI 01/15/07 1036 602157 I Americium-241 U -0.0292 +/-0.0346 0.0264 +/-0.0346 0.0543 pCi/g Bismuth-212 0.786 +/-0.309 0.163 +/-0.309 0.347 pCi/g Bismuth-214 0.975 +/-0.122 0.0367 +/-0.122 0.0778 pCi/g Cesium- 134 UI 0.00 +/-0.0324 0.0287 +/-0.0324 0.0605 pCi/g Cesium-137 0.0773 +/-0.0538 0.021 +/-0.0538 0.0445 pCi/g Cobalt-60 U 0.0156 +/-0.024 0.0216 +/-0.024 0.0473 pCi/g Europium-152 U 0.0122 +/-0.0557 0.0473 +/-0.0557 0.0993 pCi/g Europium-154 U -0.00516 +/-0.0792 0.0658 +/-0.0792 0.143 pCi/g Europium-155 U 0.0753 +/-0.0795 0.0489 +/-0.0795 0.101 pCi/g Lead-212 1.45 +/-0.0736 0.0252 +/-0.0736 0.0525 pCi/g Lead-214 1.14 +/-0.0986 0.0372 +/-0.0986 0.0778 pCi/g Manganese-54 U 0.0336 +/-0.0265 0.0241 +/-0.0265 0.051 pCi/g Niobium-94 U 0.0209 +/-0.0277 0.0214 +/-0.0277 0.0452 pCi/g Potassium-40 11.1 +/-1.00 0.199 +/-1.00 0.439 pCi/g Radium-226 0.975 +/-0.122 0.0367 +/-0.122 0.0778 pCi/g Silver-108m U -0.00725 +/-0.0194 0.0168 +/-0.0194 0.0353 pCi/g Thallium-208 0.443 +/-0.0522 0.0194 +/-0.0522 0.0411 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 68
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-014-F Project: YANK01204 Sample ID: 178924015 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
69
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-015-F Project: YANK01204 Sample ID: 178924016 Client ID: YANKOO 1 Matrix: TS Vol. Recv.:
Collect Date: 03-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 4.23%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.609 +/-0.138 0.0452 +/-0.138 0.0998 pCi/g MJHI 01/15/07 1037 602157 1 Americium-241 U -0.026 +/-0.0543 0.042 +/-0.0543 0.0875 pCi/g Bismuth-212 U 0.218 +/-0.245 0.124 +/-0.245 0.265 pCi/g Bismuth-214 0.460 +/-0.0927 0.0261 +/-0.0927 0.0562 pCi/g Cesium-134 UI 0.00 +/-0.0218 0.0181 +/-0.0218 0.039 pCi/g Cesium- 137 0.0306 +/-0.0293 0.0135 +/-0.0293 0.0292 pCi/g Cobalt-60 U 0.00823 +/-0.0173 0.0158 +/-0.0173 0.0351 pCi/g Europium- 152 U -0.0447 +/-0.0432 0.0338 +/-0.0432 0.0719 pCi/g Europium- 154 U 0.0106 +/-0.0537 0.0472 +/-0.0537 0.104 pCi/g Europium- 155 U 0.011 +/-0,0442 0.0376 +/-0.0442 0.0784 pCi/g Lead-212 0.493 +/-0.0628 0.0212 +/-0.0628 0.0444 pCi/g Lead-214 0.450 +/-0.0786 0.0266 +/-0.0786 0.0564 pCi/g Manganese-54 U 0.00324 +/-0.0158 0.0137 +/-0.0158 0.0298 pCi/g Niobium-94 U 0.00577 +/-0.0154 0.0137 +/-0.0154 0.0294 pCi/g Potassium-40 10.1 +/-0.991 0.101 +/-0.991 0.238 pCi/g Radium-226 0.460 +/-0.0927 0.0261 +/-0.0927 0.0562 pCi/g Silver- 108m U 0.00849 +/-0.0224 0.0123 +/-0.0224 0.0263 pCi/g Thallium-208 0.193 +/-0.0405 0.0124 +/-0.0405 0.027 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 70
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-015-F Project: YANK01204 Sample ID: 178924016 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
71
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-016-1 Project: YANKO 1204 Sample ID: 178924017 Client ID: YANKOO1 Matrix: TS Vol. Recv.:
Collect Date: 05-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 8.6%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MtW Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.976 +/-0.207 0.0728 +/-0.207 0.145 pCi/g MJH1 01/15/07 1020 602157 1 Americium-241 U 0.109 +/-0.0957 0.0791 +/-0.0957 0.158 pCi/g Bismuth-212 0.636 +/-0.350 0.161 +/-0.350 0.322 pCi/g Bismuth-214 0.626 +/-0.102 0.0352 +/-0.102 0.0703 pCi/g Cesium- 134 UI 0.00 +/-0.0396 0.0264 +/-0.0396 0.0528 pCi/g Cesium- 137 U 0.0244 +/-0.03 18 0.0196 +/-0.0318 0.0393 pCi/g Cobalt-60 U 0.0053 +/-0.0256 0.022 +/-0.0256 0.044 pCi/g Europium- 152 U 0.0511 +/-0.081 0.0571 +/-0.081 0.114 pCi/g Europium- 154 U 0.0196 +/-0.0745 0.0643 +/-0.0745 0.129 pCi/g Europium-155 U 0.0385 +/-0.086 0.0586 +/-0.086 0.117 pCi/g Lead-212 1.04 +/-0.111 0.0304 +/-'0.1 1 0.0608 pCi/g Lead-214 0.641 +/-0.110 0.0379 +/-0.110 0.0758 pCi/g Manganese-54 U 0.0215 +/-0.0236 0.0218 +/-0.0236 0.0436 pCi/g Niobium-94 U -0.0148 +/-0.0282 0.0193 +/-0.0282 0.0385 pCi/g Potassium-40 13.7 +/-1.30 0.186 +/-1.30 0.373 pCi/g Radium-226 0.626 +/-0.102 0.0352 +/-0.102 0.0703 pCi/g Silver- 108m U 0.0058 +/-0.0202 0.0177 +/-0.0202 0.0355 pCi/g Thallium-208 0.307 +/-0.0525 0.0204 +/-0.0525 0.0408 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 72
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-016-I Project: YANK01204 Sample ID: 178924017 Client ID: YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI , Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
73
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-017-1 Proiect: YANK01204 Sample ID: 178924018 Client ID: YANK001 Matrix: TS Vol. Recv.:
Collect Date: 05-JAN-07 Receive Date: S11-JAN-07 Collector: Client NMnti tro- 11 aOO Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt4 Rad Gamma Spec Analysis Ganmma,Solid-FSS GA M & ALL FSS 226 Ingrowth Waived
.Actinium-228 1.41 +/-0.289 0.114 +/-0.289 0.227 pCi/g MJHI 01/15/07 1021 602157 1 Americium-241 U 0.0616 +/-0.0539 0.0382 +/-0.0539 0.0763 pCi/g Bismuth-212 0.967 +/-0.508 0.256 +/-0.508 0.512 pCi/g Bismuth-214 0.712 +/-0.160 0.055 +/-0.160 0.110 pCi/g Cesium-134 UI 0.00 +/-0.0819 0.0408 +/-0.0819 0.0815 pCi/g Cesium-137 U 0.0528 +/-0.0463 0.031 +/-0.0463 0.062 pCi/g Cobalt-60 U -0.00308 +/-0.0378 0.0309 +/-0.0378 0.0618 pCi/g Europium-152 U -0.012 +/-0.106 0.0675 +/-0.106 0.135 pCi/g Europium-154 U 0.0648 +/-0.124 0.109 +/-0.124 0.218 pCi/g Europium-155 U 0.0629 +/-0.0872 0.0666 +/-0.0872 0.133 pCi/g Lead-212 1.41 +/-0.152 0.037 +/-0.152 0.074 pCi/g Lead-214 0.879 +/-0.150 0.0488 +/-0.150 0.0976 pCi/g Manganese-54 U -0.0185 +/-0.0346 0.028 +/-0.0346 0.0559 pCi/g Niobium-94 U -0.0117 +/-0.0355 0.0299 +/-0.0355 0.0597 pCi/g Potassium-40 17.0 +/-1.54 0.291 +/-1.54 0.582 pCi/g Radium-226 0.712 +/-0.160 0.055 +/-0.160 0.110 pCi/g Silver-108m U -0.0114 +/-0.0341 0.0241 +/-0.0341 0.0482 pCi/g Thallium-208 0.466 +/-0.0873 0.0279 +/-0.0873 0.0558 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 74
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-017-1 Project: YANK01204 Sample ID: 178924018 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt4
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
75
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-018-1 Project: YANK01204 Sample ID: 178924019 Client ID: YANKOO Matrix: TS Vol. Recv.:
Collect Date: 09-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 18.8%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.17 +/-0.253 0.0718 +/-0.253 0.159 pCi/g MJHI 01/15/07 1037 602157 1 Americium-241 U -0.00911 +/-0.0363 0.0312 +/-0.0363 0.0647 pCi/g Bismuth-212 0.802 +/-0.340 0.195 +/-0.340 0.419 pCi/g Bismuth-214 0.691 +/-0.117 0.0429 +/-0.117 0.0921 pCi/g Cesium-134 UI 0.00 +/-0.042 0.0343 +/-0.042 0.073 pCi/g Cesium-137 U 0.0388 +/-0.0346 0.0272 +/-0.0346 0.058 pCi/g Cobalt-60 U -0.00287 +/-0.0304 0.0245 +/-0.0304 0.0548 pCi/g Europium-152 U -0.00113 +/-0.0665 0.0509 +/-0.0665 0.108 pCi/g Europium-154 U 0.0329 +/-0.0869 0.075 +/-0.0869 0.166 pCi/g Europium-155 UI 0.00 +/-0.0967 0.0464 +/-0.0967 0.0967 pCi/g Lead-212 0.956 +/-'0.0753 0.0266 +/-0.0753 0.0561 pCi/g Lead-214 0.801 +/-0.111 0.0399 +/-0.111 0.0845 pCi/g Manganese-54 U -0.0155 +/-0.0279 0.0225 +/-0.0279 0.049 pCi/g Niobium-94 U 0.000445 +/-0.025 0.0218 +/-0.025 0.0468 pCi/g Potassium-40 13.3 +/-1.14 0.184 +/-1.14 0.428 pCi/g Radium-226 0.691 +/-0.117 0.0429 +/-0.117 0.0921 pCi/g Silver- 108m U -0.00981 +/-0.0241 0.0196 +/-0.0241 0.0419 pCi/g Thallium-208 0.272 +1/-0.0673 0.0233 +/-0.0673 0.0499 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB I 01/11/07 1039 601628 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 76
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 /
Client Sample ID: 9539-0001-018-1 Project: YANK01204 Sample ID: 178924019 Client ID: YANK00I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
77
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-019-I Proiect: YANK01204 Sample ID: 178924020 Client ID: YANKOOI Matrix: TS Vol. Recv.:
Collect Date: 09-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 16.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mti Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.169 0.045 +/-0.169 0.0899 pCi/g MJHI 01/15/07 1048 602157 1 Americium-241 U 0.0953 +/-0.112 0.0909 +/-0.112 0.182 pCi/g Bismuth-212 0.690 +/-0.184 0.096 +/-0.184 0.192 pCi/g Bismuth-214 0.711 +/-0.094 0.0257 +/-0.094 0.0514 pCi/g Cesium-134 UI 0.00 +/-0.0288 0.0176 +/-0.0288 0.0351 pCi/g Cesium-137 0.115 +/-0.0304 0.011 +/-0.0304 0.022 pCi/g Cobalt-60 U -0.0131 +/-0.015 0.0116 +/-0.015 0.0231 pCi/g Europium- 152 U 0.0102 +1/-0.0541 .0.0364 +/-0.0541 0.0728 pCi/g Europium- 154 U -0.044 +/-0.0492 0.0384 +/-0.0492 0.0767 pCi/g Europium- 155 U 0.0295 +/-0.0619 0.0501 +/-0.0619 0.100 pCi/g Lead-212 1.02 +/-0.0942 0.0217 +/-0.0942 0.0433 pCi/g Lead-214 0.826 +/-0.0939 0.0259 +/-0.0939 0.0518 pCi/g Manganese-54 U 0.00653 +/-0.0177 0.0135 +/-0.0177 0.0269 pCi/g Niobium-94 U 0.0121 +/-0.0141 0.0122 +/-0.0141 0.0245 pCi/g Potassium-40 12.2 +/-0.941 0.108 +/-0.941 0.215 pCi/g Radium-226 0.711 +/-0.094 0.0257 +/-0.094 0.0514 pCi/g Silver- 108m U 0.000374 +/-0.0136 0.0117 +/-0.0136 0.0234 pCi/g Thallium-208 0.321 +/-0.0428 0.0124 +/-0.0428 0.0249 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 78
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-019-I Project: YANK01204 Sample ID: 178924020 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
79
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-020-I Project: YANKO 1204 Sample ID: 178924021 Client ID: YANKOOl Matrix: TS Vol. Recv.:
Collect Date: 09-JAN-07 Receive Date: 11-JAN-07 Collector: Client Moisture: 24.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.0943 0.032 +/-0.0943 0.0668 pCi/g MJHI 01/15/07 1829 602159 1 Americium-241 U -0.0417 +/-0.0458 0.0393 +/-0.0458 0.0801 pCi/g Bismuth-212 0.624 +/-0.197 0.0796 +/-0.197 0.165 pCi/g Bismuth-214 0.865 +1--0.0644 0.0194 +/-0.0644 0.040 pCi/g Cesium- 134 UI 0.00 +1--0.0197 0.0136 +/-0.0197 0.0279 pCi/g Cesium- 137 0.239 -'-I- -0.0257 0.0117 +/-0.0257 0.0241 pCi/g Cobalt-60 U 0.0067 +1--0.0126 0.0108 +/-0.0126 0.0226 pCi/g Europium- 152 U -0.00446 +/-1--0.0321 0.027 +/-0.0321 0.0554 pCi/g Europium- 154 U -0.0263 +1--0.0379 0.0304 +/-0.0379 0.0637 pCi/g Europium- 155 U 0.0436 +/-1--0.0449 0.0316 +/-0.0449 0.0644 pCi/g Lead-212 1.06 +/-1--0.0436 0.0159 +/-0.0436 0.0324 pCi/g Lead-214 0.973 +1--0.0697 0.0193 +/-0.0697 0.0395 pCi/g Manganese-54 U 0.0058 +/-0.017 0.00974 +/-0.017 0.0202 pCi/g Niobium-94 Ul 0.00 +/-0.0262 0.00954 +/-0.0262 0.0197 pCi/g Potassium-40 11.2 +/-0.485 0.0921 +/-0.485 0.194 pCi/g Radium-226 0.865 +/-0.0644 0.0194 +/-0.0644 0.040 pCi/g Silver- 108m U 0.010 +/-0.011 0.00942 +/-0.011 0.0194 pCi/g Thallium-208 0.339 +/-0.0254 0.00979 +/-0.0254 0.0202 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria 80
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-020-1 Proiect: YANK01204 Sample ID: 178924021 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtt
- Analyte is a surrogate compound
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded.
The above sample is reported on a dry weight basis.
81
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-02 1-I Project: YANK01204 Sample ID: 178924022 Client ID: YANKOO1 Matrix: TS Vol. Recv.:
Collect Date: 09-JAN-07 Receive Date: 1 I-JAN-07 Collector: Client Moisture: 5.03%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.736 +/-0.132 0.0313 +/-0.132 0.0626 pCi/g MJHI 01/15/07 1725 602159 1 Americium-241 U 0.0317 +/-0.0765 0.0615 +/-0.0765 0.123 pCi/g Bismuth-212 0.408 +/-0.126 0.0705 +/-0.126 0.141 pCi/g Bismuth-214 0.454 +/-0.0641 0.0173 +/-0.0641 0.0345 pCi/g Cesium-134 UI 0.00 +/-0.0156 0.011.1 +/-0.0156 0.0223 pCi/g Cesium-137 U 0.0178 +/-0.0163 0.0101 +/-0.0163 0.0202 pCi/g Cobalt-60 U 0.000921 +/-0.0108 0.00907 +/-0.0108 0.0181 pCi/g Europium- 152 U -0.00525 +/-0.0356 0.0254 +/-0.0356 0.0507 pCi/g Europium- 154 U- 0.0194 +/-0.0345 0.0297 +/-0.0345 0.0593 pCi/g Europium- 155 U 0.0411 +/-0.043 0.0342 +/-0.043 0.0683 pCi/g Lead-212 0.663 +/-0.0618 0.0154 +/-0.0618 0.0308 pCi/g Lead-214 0.554 +/-0.065 0.019 +/-0.065 0.0381 pCi/g Manganese-54 U 0.00518 +/-0.0106 0.00935 +/-0.0106 0.0187 pCi/g Niobium-94 U-0.000892 +/-0.0104 0.00861 +/-0.0104 0.0172 pCi/g Potassium-40 11.5 +/-0.805 0.0779 +/-0.805 0.156 pCi/g Radium-226 0.454 +/-0.0641 0.0173 +/-0.0641 0.0345 pCi/g Silver- 108m U -0.00378 +/-0.00979 0.00833 +/-0.00979 0.0166 pCi/g Thallium-208 0.207 +/-0.0289 0.00879 +/-0.0289 0.0176 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/11/07 1039 601628 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound 82
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 18, 2007
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9539-0001-021-1 Project: YANKO 1204 Sample ID: 178924022 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU VIDA Units DF Analyst Date Time Batch Mt,
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager conceming this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
83
- 1.
QUALITY CONTROL
-DATA I
84
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Reoort Date: January 18, 2007 Client : Connecticut Yankee Atomic Power Page 1 of 12 362 Injun Hollow Rd East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder: 178924 Parmname NOM Sample Qual QC Units RPD% REC% Ranee Anist Date Time Rad Alpha Spec Batch 601896 QC1201260243 178924001 DUP Americium-241 U 0.00849 U -0.0257 pCi/g 397 (0% - 100%) dXA I 01/12/07 19:19 Uncert: +/-0. 11 +/-0.102 TPU: +/-0.111 +/-0.102 Curium-242 U -0.0527 U 0.0116 pCi/g 313 (0%- 100%)
Uncert: +/-0.0421 +/-0.0877 TPU: +/-0.0426 +/-0.0877 Curium-243/244 U 0.0126 U 0.0634 pCi/g 134 (0%- 100%)
Uncert: +/-0.131 +/-0.166 TPU: +/-0.131 +/-0.166 QC 1201260245 LCS Americium-241 13.1 15.2 pCi/g 116 (75%-125%) 01/13/07 08:21 Uncert: - +/-1.35 TPU: +/-2.27 Curium-242 U 0.00 pCi/g Uncert: +/-0.0615 TPU: +/-0.0615 Curium-243/244 15.8 16.3 pCi/g 103 (75%-125%)
Uncert: +/-1.40 TPU: +/-2.41 QC1201260242 MB Americium-241 U 0.140 pCi/g 01/12/07 19:19 Uncert: +/-0.171 TPU: +/-0.172 Curium-242 U 0.0477 pCi/g Uncert: +/-0.108 TPU: +/-0.108 Curium-243/244 U -0.034 pCi/g Uncert: +/-0.0876 TPU: +/-0.0877 QC 1201260244 178924001 MS Americium-241 13.1 U 0.00849 14.7 pCi/g 112 (75%-125%) 01/13/07 08:21 Uncert: +/-0.111I +/-1.29
+/-0.l II1 +/-2.17 TPU:
Curiuln-242 U -0.0527 U 0.00 pCi/g Uncert: +/-0.0421 +/-0.0605 TPU: +/-0.0426 +/-0.0605 Curium-243/244 15.8 U 0.0126 16.0 pCi/g 101 (75%-125%)
Uncert: +/-0.131 +/-1.35 TPU: +/-0.131 +/-2.33 Batch 601897 QC1201260247 178924001 DUP Plutonium-238 U 0.00119 U -0.0434 pCi/g 211 (0% - 100%) AXAI 01/15/07 08:24 85
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 2 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 601897 Uncert: +/-0.0649 +/-0.038 TPU: +/-0.0649 +/-0.0383 Plutonium-239/240 U -0.0358 U -0.139 pCi/g 118 (0%- 100%)
Uncert: +/-0.0314 +/-0.0982 TPU: +/-0.0317 +/-0.0988 QC1201260249 LCS Pluitonium-238 U 0.0605 pCi/g (75%-125%) 01/12/07 16:14 Uncert: +/-0.104 TPU: +/-0.105 Plutoniuin-239/240 12.1 11.9 pCi/g 98 (75%-125%)
Uncert: +/-1.17 TPU: +/-1.79 QC1201260246 MB Plutoniurn-238 U -0.0184 pCi/g 01/12/07 16:14 Uncert: +/-0.0544 TPU: +/-0.0544 Plutonium-239/240 U 0.0584 pCi/g Uncert: +/-0.0894 TPU: +/-0.0897 QC1201260248 178924001 MS Plutonium-238 U 0.00119 U 0.0835 pCi/g (75%-125%) 01/12/07 16:14 Uncert: +/-0.0649 +/-0.102 TPU: +/-0.0649 +/-0.102 Plutonium-239/240 12.1 U -0.0358 12.1 pCi/g 100 (75%-125%)
Uncert: +/-0.0314 +/- 1.09 TPU: +/-0.0317 +/-1.73 Batch 601898 QC1201260251 178924001 DUP Plutonium-241 U -9.26 U -3.67 pCi/g 0 (0% - 100%) IXA 1 01/16/07 08:00 Uncert: +/-9.39 +/-8.83 TPU: +/-9.39 +/-8.83 QC1201260253 LCS Plutonium-241 140 128 pCi/g 92 (75%-125%) 01/16/07 00:43 Uncert: +/-12.8 TPU: +/-18.1 QC1201260250 MB Plutonium-241 U -2.67 pCi/g 01/16/07 07:44 Uncert: +/-8.64 TPU: +/-8.64 QC1201260252 178924001 MS Plutonium-241 140 U -9.26 152 pCi/g 108 (75%-125%) 01/16/07 08:16 Uncert: +/-9.39 +/-15.7 TPU: +/-9.39 +/-22.3 Rad Gamma Spec Batch 602157 QC1201260864 178924001 DUP Actinium-228 0.659 0.550 pCi/g 18 (0% - 100%) MJHl 01/15/07 17:26 Uncert: +/-0.176 +/-0.112
+/-0.112 86
GEL LABORATORIES LLC
.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary -
Workorder: 178924 Page 3 of 12 Parmname NOM Sample Qual OC Units RPD% REC% Ranee Anist Date Time Rad Gamma Spec Batch 602157 TPU: +/-0.176 Americium-24 I U 0.00967 U -0.0166 pCi/g 756 (0% - 100%)
Uncert: +/-0.0287 +/-0.0637 TPU: +/-0.0287 +/-0.0637 Bismuth-212 0.628 0.439 pCi/g 36 (0%- 100%)
Uncert: +/-0.290 +/-0.158 TPU: +/-0.290 +/-0.158 Bismuth-214 0.591 0.524 pCi/g 12 (0%- 100%)
Uncert: +/-0.0888 +/-0.0531 TPU: +/-0.0888 +/-0.0531 Cesium- 134 ul 0.00 UI 0.00 pCi/g 47 (0%- 100%)
Uncert: +/-0.0458 +/-0.0235 TPU: +/-0.0458 +/-0.0235 Cesium-137 0.167 0.126 pCi/g 28 (0%- 100%)
Uncert: +/-0.0556 +/-0.0319 TPU: +/-0.0556 +/-0.0319 Cobalt-60 U -0.00235 U -0.00219 pCi/g 7 (0%- 100%)
Uncert: +/-0.0253 +/-0.0139 TPU: +/-0.0253 +/-0.0139 Europium- 152 U -0.0256 U 0.0132 pCi/g 624 (0%- 100%)
Uncert: +/-0.0525 +/-0.0337 TPU: +/-0.0525 +/-0.0337 Europium- 154 U -0.0453 U 0.00664 pCi/g 269 (0%- 100%)
Uncert: +/-0.0805 +/-0.0441 TPU: +/-0.0805 +/-0.0441 Europium- 155 U 0.029 U 0.0117 pCi/g 85 (0%- 100%)
Uncert: +/-0.0416 +/-0.0362 TPU: +/-0.0416 +/-0.0362 Lead-212 0.638 0.646 pCi/g I (0%- 20%)
Uncert: +/-0.058 +/-0.0452 TPU: +/-0.058 +/-0.0452 Lead-214 0.715 0.584 pCi/g 20 (0%- 20%)
Uncert: +/-0.0987 +/-0.058 TPU: +/-0.0987 +/-0.058 Manganese-54 U -0.00805 U 0.00815 pCi/g 32700 (0%- 100%)
Uncert: +/-0.0216 +/-0.014 TPU: +/-0.0216 +/-0.014 Niobium-94 U -0.000198 U -0.0022 pCi/g 167 (0%- 100%)
Uncert: +/-0.0203 +/-0.0128 TPU: +/-0.0203 +/-0.0128 Potassium-40 9.53 9.88 pCi/g 4 (o%-20%)
Uncert: +/-0.860 +/-0.551 TPU: +/-0.860 +/-0.551 Radium-226 0.591 0.524 pCi/g 12 (0%- 100%)
Uncert: +/-0.0888 +/-0.0531 TPU: +/-0.0888 +/-0.0531 Silver-108m U 0.00819 U 0.00692 pCi/g 17 (0%- 100%)
Uncert: +/-0.0187 +/-0.0112 87
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 4 of 12 Parmname NOM Sample Qual , QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 602157 TPU: +/-0.0187 +/-0.0112 Thallium-208 0.216 0.191 pCi/g 12 (0% - 100%)
Uncert: +/-0.0502 +/-0.0333 TPU: +/-0.0502 +/-0.0333 QC1201260865 LCS Actinium-228 U 0.102 pCi/g 01/15/07 10:39 Uncert: +/-0.395 TPU: +/-0.395 Americium-241 23.4 25.4 pCi/g 108 (75%-125%)
Uncert: +/-1.03 TPU: +/-1.03 Bismuth-212 U 0.295 pCi/g Uncert: +/-0.629 TPU: +/-0.629 Bismuth-214 U 0.114 pCi/g Uncert: +/-0.150 TPU: +/-0.150 Cesium- 134 U 0.0849 pCi/g Uncert: +/-0.0972 TPU: +/-0.0972 Cesium- 137 9.50 10.3 pCi/g 108 (75%-125%)
Uncert: +/-0.359 TPU: +/-0.359 Cobalt-60 13.8 14.7 pCi/g 107 (75%-125%)
Uncert: +/-0.478 TPU: +/-0.478, Europium- 152 U -0.124 pCi/g Uncert: +/-0.200 TPU: +/-0.200 Europium- 154 U 0.165 pCi/g Uncert: +/-0.191 TPU: +/-0.191 Europium- 155 U 0.129 pCi/g Uncert: +/-0.219 TPU: +/-0.219 Lead-212 U 0.147 pCi/g Uncert: +/-0.109 TPU: +/-0.109 Lead-214 U -0.147 pCi/g Uncert: +/-0.148 TPU: +/-0.148 Manganese-54 U -0.028 pCi/g Uncert: +/-0.0887 TPU: +/-0.0887 pCi/g Niobium-94 U -0.0267 Uncert: +/-0.0741 TPU: +/-0.0741 pCi/g Potassium-40 U 0.843 88
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - wwwgel.com QC Summary Workorder: 178924 Page 5 of 12 Parmname NOM Sample Qual OC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 602157 Uncert: +/-0.652 TPU: +/-0.652 Radium-226 U 0.114 pCi/g (75%-125%)
Uncert: +1-0.150 TPU: +/-0.150 Silver- 108m U -0.00197 pCi/g Uncert: +/-0.0772 TPU: +/-0.0772 Thallium-208 U 0.0495 pCi/g Uncert: +/-0.0754 TPU: +/-0.0754 QC1201260863 MB Actinium-228 U 0.0106 pCi/g 01/15/07 11:26 Uncert: +/-0.0373 TPU: +/-0.0373 Americium-241 U 0.00245 pCi/g Uncert: +/-0.0253 TPU: +/-0.0253 Bismuth-212 U 0.046 pCi/g Uncert: +/-0.0975 TPU: +/-0.0975 Bismuth-214 U 0.00958 pCi/g Uncert: +/-0.0573 TPU: +/-0.0573 Cesium- 134 U -0.00417 pCi/g Uncert: +/-0.0101 TPU: +/-0.0101 Cesium-137 U 0.0007 pCi/g Uncert: +/-0.0108 TPU: +/-0.0108 Cobalt-60 U 0.00945 pCi/g Uncert: +/-0.00972 TPU: +/-0.00972 Europium- 152 U -0.0285 pCi/g Uncert: +/-0.0328 TPU: +/-0.0328 Europium- 154 U -0.0105 pCi/g Uncert: +/-0.0292 TPU: +/-0.0292 Europium- 155 U 0.00356 pCi/g Uncert: +/-0.0241 TPU: +/-0.0241 Lead-212 U 0.0291 pCi/g Uncert: +/-0.0396 TPU: +/-0.0396 Lead-214 U 0.0155 pCi/g Uncert: +/-0.0227 TPU: +/-0.0227 89
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder: 178924 Page 6 of 12 Parmname NOM Sample Oual OC Units RPD% REC% Range Anist Date Time Parmname Rad Gamma Spec Batch 602157 Manganese-54 U -0.00175 pCi/g Uncert: +/-0.0108 TPU: +/-0.0108 Niobium-94 U 0.0151 pCi/g Uncert: +/-0.0128 TPU: +/-0.0128 Potassium-40 U 0.107 pCi/g Uncert: +/-0.114 TPU: +/-0. 114 Radium-226 U 0.00958 pCi/g Uncert: +/-0.0573 TPU: +/-0.0573 Silver-108m U 0.007 pCi/g Uncert: +/-0.0104 TPU: +/-0. 0104 Thallium-208 U 0.0181 pCi/g Uncert: +/-0.0119 TPU: +/-0.0119 Batch 602159 QC1201260867 178923021 DUP Actinium-228 0.470 0.412 pCi/g 13 (0%-100%) MJHI 01/15/07 18:31 Uncert: +/-0.112 +/-0.104 TPU: +/-0.112 +/-0.104 Americium-241 U -1.790E-05 U -0.00479 pCi/g 199 (0%- 100%)
Uncert: +/-0.0485 +/-0.0184 TPU: +/-0.0485 +/-0.0184 Bismuth-212 0.270 0.392 pCi/g 37 (0%- 100%)
Uncert: +/-0.141 +/-0.254 TPU: +/-0.141 +/-0.254 Bismuth-214 0.324 0.330 pCi/g 2 (0%- I00%)
Uncert: +/-0.0574 +/-0.0623 TPU: +/-0.0574 +/-0.0623 Cesium- 134 U1 0.00 UI 0.00 pCi/g 42 (0%- 100%)
Uncert: +/-0.0199 +/-0.0157 TPU: +/-0.0199 +/-0.0157 Cesium-137 u 0.0185 U 0.00344 pCi/g 137 (0%- 100%)
Uncert: +/-0.0166 +/-0.0146 TPU: +/-0.0166 +/-0.0146 Cobalt-60 U 0.000568 U 0.00334 pCi/g 142 (0%- 100%)
Uncert: +/-0.0102 +/-0.0153 TPU: +/-0.0102 +/-0.0153 Europium- 152 u -0.00941 U -0.0217 pCi/g 79 (0%- 100%)
Uncert: +/-0.0256 +/-0.0346 TPU: +/-0.0256 +/-0.0346 Europium- 154 u 0.0161 U -0.0145 pCi/g 3690 (0% - 100%)
Uncert: +/-0.0306 +/-0.0467 TPU: +/-0.0306 +/-0.0467 Europium- 155 u 0.0335 U 0.00826 pCi/g 121 (0%- 100%)
90
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 7 of 12 Parmname NOM Sample Qual OC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 602159 Uncert: +/-0.0281 +/-0.0296 TPU: +/-0.0281 +/-0.0296 Lead-212 0.465 0.425 pCi/g 9 (0%- 100%)
Uncert: +/-0.0462 +/-0.0349 TPU: +/-0.0462 +/-0.0349 Lead-214 0.359 0.305 pCi/g 16 (0%- 100%)
Uncert: +/-0.0537 +/-0.0455 TPU: +/-0.0537 +/-0.0455 Manganese-54 u 0.00492 U 0.00257 pCi/g 63 (0%- 100%)
Uncert: +/-0.0118 +/-0.0148 TPU: +/-0.0118 +/-0.0148 Niobium-94 U 0.000641 U 0.00442 pCi/g 149 (0% - 100%)
Uncert: +/-0.0103 +/-0.0134 TPU: +/-0.0103 +/-0.0134 Potassium-40 7.08 7.71 pCi/g 9 (0%- 20%)
Uncert: +/-0.627 +/-0.486 TPU: +/-0.627 +/-0.486 Radiurn-226 0.324 0.330 pCi/g 2 (0%- 100%)
Uncert: +/-0.0574 +/-0.0623 TPU: +/-0.0574 +/-0.0623 Silver- 108m u -0.00383 U 0.000361 pCi/g 242 (0%- 100%)
Uncert: +/-0.00875 +/-0.0115 TPU: +/-0.00875 +/-0.0115 Thallium-208 0.154 0.144 pCi/g 7 (0% - 100%)
Uncert: +/-0.0276 +/-0.0329 TPU: +/-0.0276 +/-0.0329 QC1201260868 LCS Actinium-228 U 0.126 pCi/g 01/15/07 18:31 Uncert: +/-0.177 TPU: +/-0.177 Americium-241 23.4 24.7 pCi/g 106 (75%-125%)
Uncert: +/-0.203 TPU: +/-0.203 Bismuth-212 U -0.12 pCi/g Uncert: +/-0.296 TPU: +/-0.296 Bismuth-214 U 0.00592 pCi/g Uncert: +/-0.066 TPU: +/-0.066 Cesium- 134 U 0.0198 pCi/g Uncert: +/-0.045 TPU: +/-0.045 Cesium- 137 9.50 10.2 pCi/g 108 (75%-125%)
Uncert: +/-0.160 TPU: +/-0.160 Cobalt-60 13.8 14.6 pCi/g 106 (75%-125%)
Uncert: +/-0.218 TPU: +/-0.218 91
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 8 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 602159 Europium- 152 -0.0332 pCi/g Uncert: +/-0.0834 TPU: +/-0.0834 Europium- 154 -0.00106 pCi/g Uncert: +/-0.0791 TPU: +/-0.0791 Europium- 155 0.00685 pCi/g Uncert: +/-0.0603 TPU: +/-0.0603 Lead-212 0.00459 pCi/g Uncert: +/-0.0482 TPU: +/-0.0482 Lead-214 0.0952 pCi/g Uncert: +/-0.0608 TPU: +/-0.0608 Manganese-54 -0.0315 pCi/g Uncert: +/-0.0432 TPU: +/-0.0432 Niobium-94 -0.00549 pCi/g Uncert: +/-0.0342
-TPU: +/-0.0342 Potassium-40 0.0853 pCi/g Uncert: +/-0.475 TPU: +/-0.475 Radium-226 0.00592 pCi/g (75%-125%)
Uncert: +/-0.066 TPU: +/-0.066 Silver- 108m 0.0179 pCi/g Uncert: +/-0.0323 TPU: +/-0.0323 Thallium-208 0.0314 pCi/g Uncert: +/-0.0343 TPU: +/-0.0343 QC1201260866 MB
- Actinium-228 U 0.025 pCi/g 01/15/07 18:30 Uncert: +/-0.0286 TPU: +/-0.0286 Americium-241 U -0.102 pCi/g Uncert: +/-0.0344 TPU: +/-0.0344 Bismuth-212 U 0.0447 pCi/g Uncert: +/-0.0589 TPU: +/-0.0589 Bismuth-214 UI 0.00 pCi/g Uncert: +/-0.0176 TPU: +/-0.0176 Cesium- 134 U 0.00274 pCi/g Uncert: +/-0.00793 92
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 9 of 12 Parmname NOM SamDle Oual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 602159 TPU: +/-0.00793 Cesium- 137 U 0.00225 pCi/g Uncert: +/-0.00842 TPU: +/-0.00842 Cobalt-60 U -0.00244 pCi/g Uncert: +/-0.00918 TPU: +/-0.00918 Europium- 152 U 0.00949 pCi/g Uncert: +/-0.0225 TPU: +/-0.0225 Europium- 154 U -0.00214 pCi/g Uncert: +/-0.0215 TPU: +/-0.0215 Europium- 155 U -0.0128 pCi/g Uncert: +/-0.0199 TPU: +/-0.0199 Lead-212 UI 0.00 pCi/g Uncert: +/-0.013 TPU: +/-0.013 Lead-214 U 0.000666 pCi/g Uncert: +/-0.0262 TPU: +/-0.0262 Manganese-54 U 0.00102 pCi/g Uncert: +/-0.00755 TPU: +/-0.00755 Niobium-94 U 0.00487 pCi/g Uncert: +/-0.00745 TPU: +/-0.00745 Potassium-40 UI 0.00 pCi/g Uncert: +/-0.0986 TPU: +/-0.0986 Radium-226 UI 0.00 pCi/g Uncert: +/-0.0176 TPU: +/-0.0176 Silver-108m U -0.0072 pCi/g Uncert: +/-0.00721 TPU: +/-0.00721 Thallium-208 U 0.00917 pCi/g Uncert: +/-0.0149 TPU: +/-0.0149 Rad Gas Flow Batch 601901 QC1201260262 178924001 DUP Strontium-90 U 0.00386 U 0.0113 pCi/g 0 (0% - 100%) KSDI 01/15/07 22:58 Uncert: +/-0.0267 +/-0.0197 TPU: +/-0.0267 +/-0.0197 QC1201260264 LCS Strontium-90 1.85 2.01 pCi/g 109 (75%-125%) 01/15/07 18:32 93
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 10of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gas Flow Batch 601901 Uncert: +/-0.194 TPU: +/-0.232 QC1201260261 MB Strontium-90 U -0.00867 pCi/g 01/15/07 22:58 Uncert: +/-0.0196 TPU: +/-0.0196 QC1201260263 178924001 MS Strontiurn-90 1.86 U 0.00386 1.80 pCi/g 97 (75%-125%) 01/15/07 18:32 Uncert: +/-0.0267 +/-0.190 TPU: +/-0.0267 +/-0.208 Rad Liquid Scintillation Batch 601907 QC1201260280 178924001 DUP Nickel-63 U 0.00 U -4.81 pCi/g 0 (0% - 100%) KXRI 01/15/07 11:24 Uncert: +/-9.32 +/-8.79 TPU: +/-9.32 +/-8.79 QC1201260282 LCS Nickel-63 572 483 pCi/g 85 (75%-125%) 01/15/07 11:57 Uncert: +/-24.0 TPU: +/-29.7 QC1201260279 MB Nickel-63 U -1.12 pCi/g 01/15/07 11:08 Uncert: +/-9.33 TPU: +/-9.33 QC1201260281 178924001 MS Nickel-63 572 ,U 0.00 530 pCi/g 93 (75%-125%) 01/15/07 11:41 Uncert: +/-9.32 +/-26.8 TPU: +/-9.32 +/-33.0 Batch 601908 QC1201260284 178924001 DUP Technetium-99 0.387 U 0.311 pCi/g 22 (0% - 100%) \XP 1 01/17/07 15:18 Uncert: +/-0.187 +/-0.193 TPU: +/-0.188 +/-0.193 QC1201260286 LCS Technetium-99 14.3 14.0 pCi/g 98 (75%-125%) 01/17/07 16:52 Uncert: +/-0.331 TPU: +/-0.470 QC1201260283 MB Technetium-99 U -0.00407 pCi/g 01/17/07 14:31 Uncert: +/-0.154 TPU: +/-0.154 QC1201260285 178924001 MS Technetium-99 14.8 0.387 14.8 pCi/g 97 (75%-125%) 01/17/07 16:05 Uncert: +/-0.187 +/-0.370 TPU: +/-0.188 +/-0.512 Batch 601909 QC1201260288 178923010 DUP Tritium U 0.425 U 1.18 pCi/g 0 (0% - 100%) \4XP1 01/15/07 17:06 94
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page Il of 12 Parmname NOM Sample Oual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 601909 Uncert: +/-1.30 +/-1.38 TPU: +/-1.30 +/-1.38 QC1201260290 LCS Tritium 8.17 6.75 pCi/g 83 (75%-125%) 01/15/07 18:10 Uncert: +/-1.04 TPU: +1-1.05 QC1201260287 MB Tritium U 0.265 pCi/g 01/15/07 16:35 Uncert: +/-0.647 TPU: +/-0.647 QC1201260289 178923010 MS Tritium 8.31 U 0.425 7.56 pCi/g 91 (75%-125%) 01/15/07 17:38 Uncert: +/-1.30 +/-1 .81
+/- 1.30 +/-1.81 TPU:
Batch 601910 QC1201260292 178924001 DUP Carbon- 14 U -0.00673 U -0.0176 pCi/g 0 (0% - 100%) VXP I 01/15/07 20:52 Uncert: +/-0.119 +/-0.116 TPU: +/-0.119 +/-0.116 QC1201260294 LCS Carbon- 14 7.16 7.18 pCi/g 100 (75%-125%) 01/15/07 23:00 Uncert: +/-0.216 TPU: +/-0.243 QC1201260291 MB Carbon- 14 U -0.0566 pCi/g 01/15/07 19:48 Uncert: +1-0.115 TPU: +/-0.115 QC1201260293 178924001 MS Carbon- 14 15.8 U -0.00673 14.9 pCi/g 94 (75%-125%) 01/16/07 08:43 Uncert: +/-0.119 +/-0.928 TPU: +/-0.119 +/-0.957 Batch 602972 QC1201262580 178924001 DUP Iron-55 U -17.2 U -26.7 pCi/g 0 (0% - 100%) MXP I 01/18/07 09:26 Uncert: +/-28.4 +/-23.0 TPU: +/-28.4 +/-23.0 QC1201262582 LCS Iron-55 799 795 pCi/g 100 (75%-125%) 01/18/07 09:59 Uncert: +/-66.3 TPU: +/-87.8 QC1201262579 MB Iron-55 U 31.7 pCi/g 01/18/07 09:09 Uncert: +/-37.6 TPU: +/-37.7 QC1201262581 178924001 MS Iron-55 624 U -17.2 546 pCi/g 87 (75%-125%) 01/18/07 09:42 Uncert: +/-28.4 +/-48.4 TPU: +/-28.4 +/-63.7 95
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 178924 Page 12 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a surrogate compound
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
96
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
Revision 0
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
Revision 0
ISFSI HAUL ROAD (NORTH SECTION) PRELIMINARY DATA ASSESSMENT SURVEY UNIT 9539-0001 RELEASE RECORD Attachment 4 Survey Unit: 9539-0001 Area Description ISFSI Haul Road (north section)
Classification 2 Survey Media Surface Soils Type of Survey Final Status Survey Number of Measurements 15 Static, 8 Investigative STATISTICS on TOTAL STATISTICS on NON-POPULATION PARAMETRIC POPULATION Cs-137 Co-60 Cs-137 Co-60 DCGLOp (pCi/g): 5.38E+00 2.59E+00 DCGLoP (pCi/g): 5.38E+00 2.59E+00 Minimum Value: -4.03E-03 -1.31E-02 Minimum Value: -4.03E-03 -8.86E-03 Maximum Value: 2.39E-01 4.59E-02 Maximum Value: 2.34E-01 4.59E-02 Mean: 7.60E-02 6.45E-03 Mean: 6.91 E-02 8.74E-03 Median: 4.58E-02 4.68E-03 Median: 3.76E-02 5.10E-03 Standard Deviation: 7.68E-02 1.33E-02 Standard Deviation: 7.64E-02 1.45E-02 Cs-1 37 Co-60 GPS Coordinates Fraction Sample ID Result MDA Result MDA 2a Identified 2a Identified of DCGL North East (pCi/g) (pCi/g) (pCi/g) (pCi/g) 9539-0001 -001 F
....................................................... 236053.33 ................................
................................ 669498.22 ........ 1.67E-01 0.056 !................................
- ........................f ................................ 3.84E-02 i................................
+ -2.35E-03 i................................
................................. 0.025 4.61 E-02
.......... .......i................ 0.03 9539-0001-002F 235977.12 669630.22 -2.12E-03 0.022 4.13E-02 -8.86E-03 0.030 4.48E-02 0.00 9539-0001-003F
....................................................... 235900.91
................................ i............................. 1.74E-01 .................................
669762.21 ................................. 0.031 2.67E-02 ......... :.......................
i................................ + . -4.43E-03
.............. . 0.017
................................ 2.81E-02 i................................
................................ 0.03 9539-0001-004F 235900.91 670202.21 3.66E-02 0.019 2.92E-02 + 2.81E-02 0.019 4.36E-02 + 0.02 9539-0001-005F 235900.91 670290.21 -3.46E-03 0.014 2.54E-02 9.64E-03 0.044 2.69E-02 0.00 REVISION 0 Page I of 2
ISFSI HAUL ROAD (NORTH SECTION) PRELIMINARY DATA ASSESSMENT SURVEY UNIT 9539-0001 RELEASE RECORD Attachment 4 Cs-1 37 Co-60 GPS Coordinates Fraction Result MDA Result MDA Sample ID 2o Identified 2a Identified of DCGL North East (PCi/g) (pCi/g) (pCi/g) (pCi/g)
. .......................................... ..... . ................................. ................................ .............. . . . .......... ................................. .................................. i............................... ................................. ................................. *................................
. =................................
9539-0001-006F 235900.91 670378.21 -3.05E-04 0.011 2.01 E-02 4.13E-03 0.012 2 27E-02 0.00 9539-0001-007F 235900.91 670466.20 5.79E-02 0.051 3.85E-02 + 1.76E-02 0.022 4.56E-02 0.02 9539-0001-008F 235900.91 670554.20 1.34E-01 0.052 4.74E-02 + 1.65E-02 0.025 4.91 E-02 0.03 9539-0001-009F 235824.70 669894.21 9.71 E-02 0.037 2.85E-02 + 4.59E-02 0.030 3.06E-02 + 0.04 9539-0001-01OF 235824.70 669982.21 3.76E-02 0.016 1.58E-02 + 4.25E-03 0.010 1.92E-02 0.01 9539-0001 -011F 235824.70 670686.20 -4.03E-03 0.021 3.73E-02 -4.03E-03 0.021 3.73E-02 0.00 9539-0001-012F
................................................... 235824.70 1. ..670774.20
. ................................ ............. ........ 2.34E-01 .................... . ..............0.041 I.................. *.... 3.86E-02.................... ... +
i ............................. -4.33E-03 ................................
.................................. 0.021 3.64E-02 i................................
................................ 0.04 9539-0001-013F 235748.49 670906.2 0.OOE+00 0.062 5.13E-02 5.10E-03 0.030 5.51 E-02 0.00 9539-0001-014F 1 235748.49 670994.20 7.73E-02 0.054 4.45E-02 + 1.56E-02 0.024 4.73E-02 0.02 9539-0001-015F 235672.28 671126.19 3.06E-02 0.029 2.92E-02 + 8.23E-03 0.017 3.51 E-02 0.01
....................................................... ................................. ................................ ............. ............... ................... 7............................................... ................................ *................................ ................................ i................................ ................................
9539-0001-003FS 235900.91 669762.21 1.48E-01 0.047 3.66E-02 + 1.69E-02 0.023 4.45E-02 0.03
....................................................... ................................ ............... I............ ............. .I......
9539-0001-0161 235877.73 669797.44 2.44E-02 0.032 3.93E-02 5.30E-03 0.026 4.40E-02 0.01 9539-0001-0171
....................................................... 235874.61 :;
f................................ ........669795.73 5.28E-02 ................................
'........................ ................................ 6.20E-02 !................................
0.046 i................................ +
................................ 0.038
-3.08E-03 ................................ 6.18E-02 ,................................
................................. 0.01 9539-0001-0181 235919.51 670297.22 3.88E-02 0.035 5.80E-02 + -2.87E-03 0.030 5.48E-02 0.01 9539-0001-0191 235917.66 670343.66 1.15E-01 0.030 220E-02 + -1.31E-02 0015 2 31E-02 0.02 9539-0001-0201 235878.32 670406.99 2.39E-01 0.026 2.41E-02 + 6.70E-03 0.013 2.26E-02 0.05 9539-0001-0211 235687.97 671063.09 1.78E-02 0.016 2.02E-02 + 9.21E-04 0.011 1.81E-02 0.00 REVISION 0 Page 2 of 2
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
-J Revision 0
QUANTILE PLOT FOR CESIUM-137 Survey Unit: 9539-0001 Survey Unit Name: ISFSI Haul Road (north section)
Mean: 6.911E-02 pCi/g Quantile Plot For Cs-1 37 2,50E-01 N]
2.OOE-01
- 0. 150E~-01 w
0 1,00E-01 .....
0 U
5.OOE-02 NM 0&00E+00 N 0 20 40 60 80 100 Percentage Cs- 137 Rank Percentage
-4.03E-03 1 3.3%
-3.46E-03 2 10.0%
-2.121!;-03 3 16.7%
-3.05 A-04 '4 23.3%
0.00E+00 5 30.0%
3.06E-02 6 36.7%
3.66E-02 7 43.3%
3*76fA-0 8 50.0%
5.79A-02 9 56.7%
7.73E-02 10 63.3%
9.71 E-02 11 70.0%
1.34E-01 12 76.7%
1.67f-01 13 83.3%
1.74E-0(I 14 90.0%
2.34E-00 15 96.7%
Wo JI)KD WI k Tub~mitted by! ate ev d ty/Date
FREQUIENCY PLOT FOR CIESIUM-137 Survey Unit: 9539-0001 Survey Unit Name: ISFS IIHaul Road (north section)
Mean: 6.911`-021 pCi/g Frequency Plot For Cs-137 10 8
6 4
U-2 0
3.56E-02 7.53E-02 1,15E-01 1.55E-0t 1.94E-01 2.34E-01 Upper End Value (pCi/g)
Upper End Observation Observation Value Frequency Frequency 3.566E-02 6 40%
7.531-02 20%
1.15 E-01 13%
1.55E-01 2 7%
1.94E-0 1 21 13%
2.34E'1- 7%
Total: 15 100%
2,y117J' 1 of 1
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Revision 0
Connecticut Yankee Decommissioning Project GPP-GGGR-R5121-001 Attachment B, Health Physics Procedure Rev.CY-001 MAJOR Sign Test Calculation Sheet for Multiple Radionuclides SurveyArea Number: 9539 Survey Unit Number: 0001 WPIR #: 2006-0048 Survey Area Name: ISFSI Haul Road Classification: 2 TYPE I (d error): 0.05 N: 15 (north section)
Radionuclides: . Radionuclide 2nd Radionuclide 3r dRadionuclide 4th Radionuclide Cs-1 37 Co-60 DCGL: 5.38E+00 2.59E+00 Results 1 st Results 2nd Results 3c Results 4 th Weighted Sum 1-WS Sign Radionuclide Radionuclide Radionuclide Radionuclide (WI)
(pCilg) (pCifg) (pCi/g) (pCi/g) 1.67E-01 -2,35E-03 0.03 0.97 +1
-2,12E-03 -8&86E-03 0.00 1,00 +1 1.74E-01 -4.43E-03 0.03 0:97 +1
,3,66E-02
. 2.81E-02 0.02 0.98 +1
-3.46E-03 9,64E-03 0,00 1.00 +1
-3.05E-04 4.13E-03 0.00 1.00 +1 5.79E-02 1376E-02 0,02 0.98 +1 1.34E-01 1.65E-02 0.03 0.97 +1 9.71 E-02 4.59E-02 0.-04 0.96 +1 3.76E-02 4.25E-03 0,01 0.99 "+t
-4.03E-03 -4.03E-03 0,00 1.00 +1 2.34E-01 -4.33E-03 0,04 0.96 +1 0.OOE+00 5.1oE&03 0.00 1.00 +1 7.73E-02 1.56E-02 0.02 0.98 +-1 3.06E-02 8,23E-03 1 0.01 0.99 +1 Number of positive differences (S+) i5 Critical Value 11 Survey Unit Meets the Acceptance Criteria Performed by: David Wojtkowial k. Date: 1/23/2007
.Independent Review by: >A, Date: I !-
Page 1 of 1
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Revision 0
Ilealth Physics Procedure 24265-()OO-GPlI-G(3GR-R5 124-0004tcv.CY-000 Attachment A 1le~dth Physics Pocedare 24265-000-GPP-GGCiR-R5 I 24-(J00-Rex.CY-(.)0() ~'\ttaehment A Split Sample Assessment Form Survey it i 0001 Survey Init Name: ISI'SI Haul 1(oa (north section)
Sample Plan or WPIR#: 2006-0048 SMI.#: 9539-0001-003 Sample
Description:
Comparison of split samples collected from sample measurement location #3 and analyzed using gamma spectroscopy by oT:-site Vendor Laboratory, Ihe standard sample was 9539-0001-003F, the comparison sample was 9539-0001-003FS, STIANDARD) COM PARI SO.N None , acceptance criteria used to split samples.
Re Soluti On, 0, - 2.
0.6 .. 1,66 16-50 0.75 - 1.33 51 -200 0.80 1.25 0.38 .- 1. 1I D)ate:
\-
Page I of I
ISFSI HAUL ROAD (NORTHERN SECTION)
SURVEY UNIT 9539-0001 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)
Revision 0
A Surface ol Report Assessment Summary Site. 9539 Planner(s): Wojo Survey Unit Name: 9539-0001a Report Number: 1 Survey Unit Samples:
Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment
Conclusion:
Reject Null Hypothesis (Survey Unit PASSES)
Retrospective Power C.urve 1
C 0,9 4+--
0,.8 07 0.6 (j~
0:5 T__ _I 0.4 0.3 F
0.2 0.1 n
0.0 02 0,4 0.6 0.8 1.0 1.2 Unity Rule Sxnt-of-Ratios, including background Prospective Power 0 i-beta .... Actual Power LB66R Estimated Power m DCGL ... Retrospective Power.
COMPASS v10.02P 2t11312007 Page.1