-ok2e f1 Final Status Survey Final Report Phase VII Appendix Al Survey Unit Release Record 9302-0000, Northwest Protected Area Grounds May 2007

CYAPCO FINAL STATUS SURVEY RELEASE RECORD NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 Prepared By.:

.[L[oV('/Ajjný&55e FSS Engineer U

Reviewed,.-_______.

FSS v

ingineer Approved By:Tc Supr M

Tedinical Support N'Lan ger Date:

Date:

Revision 0

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLASSIFICATION BASIS...............................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..........................................

5

4.

SU RV EY D ESIGN............................................................................

8

5.

SURVEY IMPLEMENTATION.......................................................

12

6.

SURVEY RESULTS.......................................................................

13

7.

QUALITY CONTROL......................................................................

19

8.

INVESTIGATIONS AND RESULTS.............................................

19

9.

REMEDIATION AND RESULTS..................................................

19

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......... 19
11. DATA QUALITY ASSESSMENT (DQA).....................................

20

12. A N O M A LIE S...................................................................................

21

13. C O N C LU SIO N.................................................................................

21

14. ATTA CHM EN TS............................................................................

22 14.1 - Figures (5 pages including cover) 14.2 Attachment 2 - Scan Results 3 pages including cover) 14.3 Attachment 3 - Laboratory Data (112 pages including cover) 14.4 Attachment 4 - DQA Results (16 pages including covers)

TOTAL 158 Revision 0

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9302-0000, is an open land surface soil survey area located in the northwestern portion of the former protected area and outside of the former Radiologically Controlled Area (RCA). Survey Unit 9302-0000 is designated as Final Status Survey (FSS) Class 3 and consists of approximately three thousand four hundred and ninety (3,490) square meters of open land and is located approximately one thousand one hundred and twenty-five (1,125) feet from the reference coordinate system benchmark used at Haddam Neck Plant (HINP) (see ).

The site benchmark is based on the Connecticut State Plan System North American Datum (NAD) 1927 (Northing 237370.20, Easting 667394.51). The topography is fairly level throughout Survey Area 9302 with a slight slope from east to west, toward the Connecticut River. This survey unit is bounded on the north (plant north is oriented by the general north to south flow of the Connecticut River) by Survey Unit 9514-0000, a Class 3 survey unit, on the east by Survey Unit 9313-0000, a Class 2 survey unit, on the south by 9306-0000 and 9304-0001, both Class 2 survey units and on the west by 9512-0000, a Class 3 survey unit.

The reference coordinates associated with this survey unit are E002 through E006 by S062 through S067 (refer to "HNP License Termination Plan" (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."

The "Classification Basis Summary" conducted for Survey Unit 9302-0000 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement,"

c) Historic and current survey records review, d) Visual inspections and a "walk-down."

The Historical Site Assessment (HSA) and Supplement, as well as, other historical documents (e.g., the IOCFR50.75(g)(1) files) identify a number of events that may have impacted this survey area.

a. ACR# 97-1055-Floor monitor identified three (3) small radioactive spots embedded in the asphalt north of the Turbine Building roll-up doors, east of GS-1 and inside the Turbine Building.

Revision 0 3

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD

b. CR# 98-0992-During a clean-up outside the Radiological Control Area (RCA), sand was inadvertently scooped up and placed in a dumpster.

Follow-up analysis indicated that the sand contained low levels of radioactive material above the environmental release levels.

c.

CR# 02-0037-A mop head containing licensed radioactive material was found in the industrial area trash.

d. CR# 03-0450-Fixed contamination (3,400 ccpm) was found in the asphalt outside the North RCA gate.
e.

CR# 03-0562-Radioactive material was found at GS-1.

f.

CR# 05-0509-Several Barrels were identified during excavation of the southwest portion of the former Service Building.

g. CR# 05-0579-Spill at Chemistry trailer.
h. CR# 05-0736-The north waste storage tent area was leaking through the north berm.

The radiological assessments and characterization surveys in this area to support decommissioning activities commenced in 2004 and continued through 2006 as work progressed. Sampling was performed in the footprints of the PBX Utilities and Commodities Tent or the location of the Former ADMREC Buildings (numbers 201, 134 & 180). Soil samples were analyzed at the on-site laboratory by Gamma Spectroscopic Analysis. A total of fourteen (14) demolition support or characterization samples were identified from this survey area. All of these samples were utilized to determine both the radionuclide(s) of concern and the standard deviation of the sample population for FSS plan development.

Cs-137 and Co-60 were positively identified (i.e. a result greater than two (2) standard deviations uncertainty) in eight (8) of the fourteen (14) samples in concentrations up to 0.6% of the Operational Derived Concentration Guideline Level (DCGL) when incorporating the "sum of fractions". Therefore, both Cs-137 and Co-60 are both identified as radionuclides of concern for FSS. Based on the lack of evidence in the HSA and the sample results from adjacent survey areas, HTD radionuclides were de-selected as radionuclides of concern for this FSS plan. A summary of the demolition support and surface characterization sample results are provided in Table 1.

Revision 0 4

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD Parameter Cs-137 Co-60 Operational Soil Derived Concentration Guideline Level (DCGL) (pCi/g):

4.75E+00 2.29E+00 Minimum Value:

-2.28E-03

-1.05E-02 Maximum Value:

9.1 1E-02 9.38E-02 Mean:

1.55E-02 8.64E-03 Median:

1.86E-03

-4.20E-04 Standard Deviation:

5.16E-02 5.24E-02 The FSS Engineer performed a visual inspection and walk-down on October 31, 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing and future groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon a review of the historical information and the results of the Characterization Survey data, it was concluded that there was a low probability for residual radioactivity at levels approaching a small fraction of the DCGLs, justifying a final survey unit classification of Class 3 (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS plan.

Revision 0 5

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9302-0000 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the

.:development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation I shows the mathematical relationship between the three (3) components and the total dose.

Equation I H Total HSoil + HExistingGW + HFutureG W The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

CY memo ISC 06-024 addresses the impact of existing and future groundwater on specific survey areas at CY. CY memo ISC 06-024 states that Survey Area 9302 is affected by existing groundwater and is also considered impacted by future groundwater radioactive contamination, as there are concrete foundations or footings remaining within the groundwater saturated zone in the area.

Therefore, the dose contribution from existing groundwater in Survey Unit 9302-0000 is bounded by two (2) mrem/yr TEDE and the dose contribution from future groundwater, the third dose component, is also two (2) mrem/yr TEDE.

Equation 2 19 mrem/yrotaIl = 15 mremnyrsil + 2 mremlyrExisting Gw+ 2 mrem/yrFutureGw The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity Revision 0 6

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD resulting in fifteen (15) mrem/yr TEDE is designated as the Operational DCGL (DCGLop), and has been established for the radionuclides of concern as provided in Table 2.

Mn-54 1.74E+01 1.05E+01 6.96E-01 Fe-55 2.74E+04 1.64E+04 1.1 OE+03 Co-60 3.81E+00 2.29E+00 1.52E-01 Ni-63 7.23E+02 4.34E+02 2.89E+01 Sr-90 1.55E+00 9.28E-01 6.20E-02 Nb-94 7.12E+00 4.27E+00 2.85E-01 Tc-99 1.26E+01 7.56E+00 5.04E-01 Ag-108m 7.14E+00 4.29E+00 2.86E-01 Cs-134 4.67E+00 2.80E+00 1.87E-01 Cs-137 7.91E+00 4.75E+00 3.16E-01 Eu-152 1.01E+01 6.04E+00 4.04E-01 Eu-154 9.29E+00 5.57E+00 3.72E-01 Eu-155 3.92E+02 2.35E+02 1.57E+01 Pu-238 2.96E+01 1.78E+01 1.18E+00 Pu-239/240 2.67E+01 1.60E+01 1.07E+00 Pu-241 8.70E+02 5.22E+02 3.48E+01 Am-241 5" 2.58E+01 1.55E+01 1.03E+00 Cm-243/244 2.90E+01 1.74E+O 1 1.1 6E+00 (1) Bold indicates those radionuclides considered to be hard to detect (2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 an are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to achieving fifteen (15) mrem/yr TEDE (4) The required Minimum Detectable Concentration (MDC) is equivalent to achieving one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). However, the preferred result is the alpha spectroscopy when both analyses are performed.

Revision 0 7

Revision 0 7

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

As stated previously, Cs-137 and Co-60 were positively identified (i.e. a result greater than two (2) standard deviations uncertainty) in eight (8) of the fourteen (14) samples at concentrations up to 0.6% of the Operational DCGL when incorporating the "sum of fractions". Therefore, both Cs-137 and Co-60 were identified as radionuclides of concern for FSS. Based on the lack of dvidence in the HSA and the sample results from adjacent survey areas, HTD radionuclides were de-selected as radionuclides of concern for this FSS plan. A summary of the post remediation and characterization sample results are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL.

Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results.

Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS.

Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".

The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that both Cs-137 and Co-60 would be the radionuclides of concern in Survey Unit 9302-0000 (refer to Section 3). The characterization survey did not identify any HTD radionuclides of concern for this survey unit.

Subsequently, surrogate DCGLs were not required for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".

Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design.

Radionuclide screening or de-selection is a process where the dose contribution from an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 3 area and discrete, elevated areas of contamination were not expected.

Revision 0 8

Revision 0 8

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.98 to maintain the relative shift (A/a) in the range of 1 and 3.

The resulting relative shift was 2.00.

A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing.

Additionally, three (3) judgmental or biased surface soil samples were collected within this survey unit. Two (2) of the judgmental samples were located in the vicinity of the east end of the survey unit (closest to the Radiological Control Area) and one (1) additional judgmental sample was located in the vicinity of GS-1. The general locations of the judgmental samples are illustrated in Attachment 1 and the coordinates are provided in Table 3.

The locations of the fifteen (15) soil samples used for non-parametric testing were determined randomly using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey." Random sampling locations were selected for this survey unit, which is appropriate for a Class 3 area. Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample measurement numerical designations are provided along with the GPS coordinates in Table 3.

Revision 0 9

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD 9302-0000-001F 236536.99 668175.09 9302-0000-002F 236567.86 668224.00 9302-0000-003F 236591.28 668258.00 9302-0000-004F 236483.34 668233.63 9302-0000-005F 236469.57 668279.00 9302-0000-006F 236501.98 668296.15 9302-0000-007F 236520.31 668294.47 9302-0000-008F 236473.25 668328.47 9302-0000-009F 9302-0000-009F 236444.96 668320.92 9302-0000-01OF 236405.78 668374.20 9302-0000-011iF 236420.54 668374.31 9302-0000-012F 236438.30 668388.42 9520-0001-013F/S 236468.02 668393.32 9302-0000-01 4F 236488.12 668384.33 9302-0000-015F/S 236465.23 668444.22 9302-0000-016B 236495.40 668405.48 9302-0000-017B 236530.36 668359.51 9302-0000-018B 236518.40 668249.31 9302-0000-0191 236525.67 668362.81 (1) F designates a Final Status Survey sample that was used for non-parametric testing, S designates a split sample, B designates a biased or judgmental sample and I designates an investigative sample location.

Revision 0 10

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory.

This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.

Table 5-9 of the LTP states that the scanning coverage requirements for an outdoor Class 3 area are judgmental.

The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Based on the historical site assessment, the characterization data available, and the use of this survey unit, it was determined that scanning was necessary to be performed in two (2) separate areas. The total surface area to be scanned was approximately 10% of the survey unit. A map of the scan grid locations is provided in Attachment 1.

For this Class 3 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Revision 0 I1I

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD Survey Unit Land Area 3,490 m2 Based on AutoCAD-LT 15 Type 1 and Type 2 errors were

(.15 random 0.05, sigma was 0.052 pCi/g for Number of Measurements locations), 3 biased both Cs-137 and Co-60, the Iinvestigative LBGR was set at 0.98 to maintain and 1 locative Relative Shift in the range sample locations between 1 and 3 Grid Spacing No grids were established for this N/A Class 3 survey unit DCGL 4.75 pCi/g Cs-137 Administratively set to achieve 2.29 pCi/g Co-60 fifteen (15) mrem/yr TEDE (1) 4.75 pCi/g Cs-137 The Operational DCGL meets the Soil Investigation Level pCi/g Co-60 LTP criteria for a Class 3 survey unit Scan Survey Area Approximately 10%

The LTP requires judgmental Coverage of the area scanning coverage for Class 3 survey units Detectable over Administratively set to achieve Scan Investigation Level background(2) fifteen (15) mrem/yr TEDE (1)

(1) The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024).

(2) Scan Investigation Level or Action Level=Background (B) + Minimum Detectable Count Rate (MDCR) and the MDCR=l.38x/((B)/('/pxt)) where p=surveyor efficiency, in accordance with BCY-HP-0081.

5.

SURVEY IMPLEMENTATION Final status survey field activities were conducted under Final Status Survey Plan 9302-0000. The FSS plan included a job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Two (2) scan areas were established that constituted approximately 10% of the surface area of Survey Unit 9302-0000. Grid lines, one (1) meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,510 counts per minute (cpm) up to 9,330 cpm.

Revision 0 12

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD The scan areas were established and scanned for elevated readings (see for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 10% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Three (3) judgmental or biased surface soil samples (9302-0000-016B, 9302-0000-017B and 9302-0000-018F) were identified and collected within this survey unit.

Two (2) samples (9302-0000-001F and 9302-0000-014F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of two (2) samples (9302-0000-013F and 9302-0000-015F) for "split sample" analysis.

6.

SURVEY RESULTS All field survey activities were conducted between March 29, 2007 and April 3, 2007.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations. Scan results for the entire survey unit are provided in Attachment 2.

Revision 0 13 Revision 0 13

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD 1

6.19 6.72 NO 2

6.87 8.061 NO 3

8.06 9.01 NO 4

6.35 6.87 NO 5

7.34 7.91 NO 6

7.11 7.96 NO 7

6.96 7.69 NO 8

7.31 7.89 NO 9

9.29 10.1 NO 10 10.4 10.8 NO 11 10.9 12.4 NO 12 11.5 12.3 NO 13 10.7 11.4 NO 14 8.93 9.09 NO 15 9.39 10.1 NO 16 8.64 9.06 NO 17 9.36 10.1 NO 18 6.05 6.541 NO (1) The action level is based on a measurement above ambiei with the FSS plan t background in accordance Revision 0 14

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD The scan areas, that comprised approximately 10% of the total surface area for the survey unit, were scanned for elevated radiation levels.

The areas were scanned in accordance with the FSS plan on April 3, 2007.

One (1) elevated measurement location was identified during scanning.

Table 6 provides an overview of the scan area survey. Complete scan results are provided in Attachment 2.

1...1-6 12.2 9.81-10.7...o.-o0-ER-o..

09302-0000-0191 2

1-6 8.01 7.66-8.72 None None (1) The action level is based on a measurement above ambient background The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the three (3) biased samples and the one (1) investigative sample using gamma spectroscopy.

Cs-137 and Co-60 were the only radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).

Cs-137 was identified in five (5) and Co-60 was identified in one (1) of the fifteen (15) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels approaching the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.

Revision 0 15

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD 9302-0000-001F 1.09E-02 5.63E-03 9302-0000-002F 4.31E-02 3.59E-03 9302-0000-003F 4.11 E-02

-1.89E-02 9302-0000-004F

-5.37E-03

-7.14E-03 9302-0000-005F 2.27E-03

-1.24E-02 9302-0000-006F 1.48E-02 2.12E-02 9302-0000-007F 4.96E-02 1.59E-02 9302-0000-008F

-1.61E-03

-3.63E-02 9302-0000-009F 1.70E-02 6.46E-05 9302-0000-01OF 2.15E-01 1.1OE-01 9302-0000-011F 3.19E-02 1.40E-02 9302-0000-012F

-4.12E-03 1.42E-02 9302-0000-013F

-3.62E-03 2.12E-02 9302-0000-014F 2.85E-03

-4.64E-03 9302-0000-015F

-3.24E-03 1.11 E-02 The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.

No HTD radionuclides were positively identified (i.e., a result greater than two (2) standard deviations uncertainty).

In accordance with LTP Section 5.4.7.2, "Gross Activity DCGLs", the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.

Revision 0 16 Revision 0 16

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD The "sum-of-fractions" or "unity rule" is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The unity rule is:

Equation 3 C,

C2 C.

+

+...........

< 1 DCGL, DCGL2

DCGL, Where:

Cn = concentration of radionuclide n and DCGLn = DCGL of radionuclide n.

The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9302-0000 are provided in Table 8 below.

Revision 0 17 Revision 0 17

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD 9302-0000-001F L.u

-1)Z 0.005 9302-0000-002F 4.3 1E-'02 3.59E-03 0.011 9302-0000-003F 4.11E-02 0.008 9302-0000-004F 0.000 9302-0000-005F 2.27E-03 0.000 9302-0000-006F 1.48E-02.

2.12E-02 0.012 9302-0000-007F 4.96E-02 1.59E-02 0.017 9302-0000-008F 0.000 9302-0000-009F 1.70E-02 6.46E-05 0.004 9302-0000-01OF 2.15E-01 1.1OE-01 0.093 9302-0000-011F 3.19E-02 1.40E-02 0.013 9302-0000-012F 1.42E-02 0.005 9302-0000-013F

-2.12E-02 0.008 9302-0000-014F 2.85E-03 0.000 9302-0000-015F 51.E1 E-02 0.005 9302-0000-016B 2.04E-02 3.52E-02 0.020 9302-0000-017B 2.05E-02 1.05E-04 0.004 9302-0000-018B 0.000 (1) The Operational DCGL from Table 2 is 4.75 pCi/g for Cs-137 and 2.29 pCi/g for Co-60 to achieve fifteen (15) mrem/yr TEDE respectively.

(2) "-"indicates that the sample activity was a negative value.

Revision 0 18 Revision 0 18

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Two (2) sample locations were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". There was acceptable agreement between the field split results at locations 9302-0000-013F and 9302-0000-015F.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS One (1) investigative sample was collected from scan area 1 at a location that exhibited an elevated scan reading. The investigative sample results are shown in Table 9 below.

'IIl I.etotive Sampe Resuilts_______

~Samiple Numiber

('Cs-137

~

C$.o-69 I UnitFraction"~;

9302-0000-0191 8.61 E-04

-0.000 (1)

The Operational DCGL from Table 2 is 4.75 pCi/g for Cs-137 and 2.29 pCi/g for Co-60 to achieve fifteen (15) mrem/yr TEDE respectively.

(2)

"-"Indicates that the sample activity was a negative value.

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan for this survey unit.

Revision 0 19

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency. The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 10.

DCGLop:

4.75E+00 2.29E+00 Minimum Value:

-5.37E-03

-3.63E-02 Maximum Value:

2.15E-01 1.1OE-01 Mean:

2.74E-02 8.26E-03 Median:

1.09E-02 5.63E-03 Standard Deviation:

5.67E-02 3.20E-02 For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was about 29% of the standard deviation which indicates some skewness in the data.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 3.15 for Cs-137.

Revision 0 20

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD Co-60, although included in the FSS plan for compliance purposes, was positively identified in only one (1) of the fifteen (15) samples collected for non-parametric statistical testing. Assessment of the basic statistical quantities and graphical representation of Co-60 was not considered useful given the limited number of statistically significant data points to represent the distribution.

All

data, assessments, and graphical representations are provided in.
12.

ANOMALIES No anomalies were noted.

13.

CONCLUSION Survey Unit 9302-0000 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

All identified radionuclides of concern were used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 3.

The dose contribution from soil is 0.196 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is considered impacted by future groundwater radioactive contamination, as there are underground foundations and footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is two (2) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 4.196 mrem/yr TEDE.

Therefore, Survey Unit 9302-0000 is acceptable for unrestricted release.

Revision 0 21

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 22 Revision 0 22

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 1 (FIGURES)

Revision 0

0$

I

-7,

/

Bedcmcr*

- 667394.51 Figure I Connecticut Yankee Atomic Power Company Cy Site Map With Reference To Survey Unit 9302-0000

93..02-0000 17 19 16 03 15 0

~d O

14 13 07 02 08 06 12 11 18

~- p~. ~

09 05 10 01 04 L..

Figure 2 Conaecticut Yankee Atomic Power Company Survey Unit 9302-0000 Sample Locaions April 2007 Reviswon: 0 Created by.- R. Mmsengill

9302-0000 0.041 0.043 0.021 0.001 0.003 0.020

-0.003 O0~*R 0.050 0.015

-0.004

-0.004 0.032 0.215

-0.002

-0.004

'I-

~

0.017 0.002 0.011

-0.005 L..

Figure 3 Connecticut Yankee Atomic Power Company Cesium -137 Posting Plot for Survey Unit 9302-~0X0 s

0Creatcd by: R. Massengitl Rev

w 0

9302-0000 0.000

-0.019

-0.013

-0.005 0.011 0.035 04.-rkR-O LbbCk 0.004 0.016 0.021 0.021 0.014 0.014 0.110

-0.036

-0.006 0.000

-0.012 0.006

-0.007 r_- --

I i

Figur Cormectfcut Yankee Atomic Power Company Cobalh-60 Postng Plot for Swvcy Unit 9302-0000 April 2007 Creatcd by: R. Masscrgill Rcvisoa,; 0 i

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Revision 0

SURVEY UNIT 9302-0000 SAMPLE LOCATION SCAN RESULTS SurveLocatnLo 9 Da t LcTime

nReadi, MDCR Action.L.

>AL E-,0OSiN.Probe SIN

.(cpm)

(cpm)

(cpm)

(,+,=Yes) 9302-00L-0Q1-0 3/292 007 14:03:00 5.65E+03 1,07E+03 6J,72E3

1111 1004 9302-00 SL-00-01-0!

3/2912007 14:05:00 68,19E+03 1111 1004 90-0ý.0-,BL-00-02-0 319207 1:60 6.8E0

't8EfO3 'K8.06E+03 "I11l

>~1004' 9302-00-SL-00-02-0 3/29/2007 14:08:00 6.87E+03 1111 1004 9302-00-BL-00-0370 3/2912007' 1I4:(900 7,75E+03 I 26E+03 9 ".E...

11...

1004 9302-00-SL-00-03-0 3/29/2007 14121:00 8.06E+03 1111 1004 9302-00-BL-00-04-0 3129/2007 14:12:00 5.78E+03' 1, 09E+03

,E87E+03 1111 1004 9332000-SL-00-00-0 i/29/2007 14:13:00 6,35E+03 1111 1004 9302-00-SL-0004 3/29/2007 14 1500: 6*9 03 1.17E+037.91E+03 ii O04 9302-00-SL-00-05-0 3/29/2007 14:16:00 7.34E+03 1

i1 1004 9302-00-SL-00-06-0.

3129/2007.

14:17:00 6.780E+03 1E

.3 111.

1004 9302-00-SL-00-06-0 3/29/2007 14:18:00 7.11 E+03 11 11 1004 9302-00-BL-00-07-0 3/2912007, 14:19'0'0 6.54E+03

~1.15E+03 7,69E+03 1111 i

1004 9302-00-SL-00-07-0 3129/2007 14+21:00

&.96E+03 i1.I 1004 930-0-8-008-0 3129/2007:

14:22:00' 6.72E+03,q1. 1 7E 03 7.89SE+03 ~

I9~

9302-00-SL-00008-0:,3/29/2007 14:26:00 7.31 E60.03 1111 1004 930210O6BLO0A09.;0 329/07'. 14:27:00

&76E+03 1.34E+03 1.01 E+04 1111 10904 9302-00-SL-00-09-0 3/2912007 14:29,00 919E+03 1111i 1004 9302b0-oB8L-00-10-0

'3.129/2007' 14:31:00 9 45E+/-03

,1.39E+03: 1.08E+04',11 lil

~1004 9302-00-SL-00-.10-0 3

.:/29/2007 14:35:00 1 04E+04 11.11 1004 930'2-0:SBL-00-81 -0 3/29/2007' 14:36:00 1.09E+04I.. 49E03 i1.24E+04 il1 1004 9302-00-SL-00-11-0 3/29/2007 14:38:00 1,09E+'04 1111 1004 930K0 -f800i20 3/29/2007 1i4:'39:00' 1.08E+04 1~I,48E+03" 1.23E+04

'il "'

11 1 004w 9302-00-SL-00-12-0: 3/29/2007 14:42:00 1.15E+04 l4Ei3 11 1004

,2O0 -B'0'1.0 3/920K 44:

o '.OE+'04i 1.3E101 3

.4E+~04 1111 10Y04 9302-00-SL-00-13-0 3/29/2007

'14:45:00 1,07E+04 11111 04 9,302-00-BL-00-14-0 3/2912007 14ý700 7,83E+03 1,610 9,09E+03, 1111

,.1004 9 1302-00-SL-00-1 4-0 3/29/2007 14:48:00 8 93E+03 1111

'1004 93q2-O0-BL-0'0-15-0,3/29/2007.

14-50:00 8-73E+03 11.33E+031 1.01 E+04, 1,1iV l

1004~

9302-00-SL-00-1 5-0 3/29/2007 14:51:00 9.39E+03 11.11 1004 930-ý00 -BL-0O<16-O'i 3/29/2007; 1~4:53:00 7,80E+03 '1.26E+031 9.06E+03 Iy~

11 1~004~

9302-00-5L.0016-0 3/29/2007" 14ý54:00 8.64E+03,:

111 1004 G30200ý6'L00'-17-0 3/29/2007> 14:55 00 8.76E+!03A'1-34E+03 1.01 E+04

"'1"11l

~1004' 9302-00-SL 17-0 3/2912007 :14:5700 9,36Ei-03 1,111 1004 9302-00-bL-00-18-0 312912007' 14:59:00 5.48E+03 '1,06E+103 6,54E+03 1111 100 9302-00-SL-00-1 8-0; 3/29/2007 15"02:00 6.05Et03 1111 1004 K S'*rvey Areis Recwa~s6*302',ýýCAN RFSUL 51,032907,.1 111 aflknion, i s 1

4/4/2007

SURVEY UNIT 9302-0000 SCAN AREA SURVEY RESULTS Survey Location Log DateLog Time'l Reading MDC.R Action L.1

>AL IE-600 S/N, Probe SIN I

I I

(cpm)_I (cpm)_I (cpm)_ I("+"=Yes) I I

9302-00-BC-01-01-0 9302-00-SC-01-01-0 9302-00-BC-01-02-0 9302-00-SC-01-02-0 9302-00-BC-01-03-0 9302-00-SC-01-03-0 9302-00-BC-01-04-0 9302-00-SC-01-04-0 9302-00-BC-01-05-0 9302-00-SC-01-05-0 9302-00-BC-01-06-0 9302-00-SC-01-06-0 9302-00-ER-01-06-1 9302-00-BC-02-01-0 9302-00-SC-02-01 -0 9302-00-BC-02-02-0 9302-00-SC-02-02-0 9302-00-BC-02-03-0 9302-00-SC-02-03-0 9302-00-BC-02-04-0 9302-00-SC-02-04-0 9302-00-BC-02-05-0 9302-00-SC-02-05-0 9302-00-BC-02-06-0 9302-00-SC-02-06-0 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 4/3/2007 7:51:00 7:55:00 7:55:00 8:00:00 8:02:00 8:0500 8:06:00 8:09:00 8:14:00 8:17:00 8:18:00 8:22:00 9:52:00 7:50:00 7:52:00 7:53:00 7:56M00 7:57:00 8:0000 8:00:00 8:03i00 8:04:00 8:06:00 8:07:00 8 10 00 8.49E+03 9 39E+03 8.98E+03 9OOE+03 9.08E+03 9.83E+03 9.33E+03 9.98E+03 9.04E+03 9.66E+03 9.30E+03 9.65E+03 1 22E+04 7.06E+03 6.68E+03 6.67E+03 7 45E+03 7.48E+03 7 69E+03 7.04E+03 8,01 E+03 6.54E+03 6&82E+03 6.51 E+03 6 68E+03 1.32E+03 9.81E+03 1.35E+03 1.03E+04 1.36E+03 1.04E+04 1.38E+03 1.07E+04 1.36E+03 1 04E+04 1.38E+03 1.07E+04 1.20E+03 8&26E+03 1 17E+03 7.84E+03 1.24E+03 8.72E+03 1.20E+03 8.24E+03 1.15E+03 7.69E+03 1 15E+03 7.66E+03 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117

+

1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1007 1007 1007 1007 1007 1007 1007 1007 1007 1007 1007 1007 1007 1

SSCAN ARLA SUMM",R 4'4!2

,0 4/4/2007

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

Revision 0

TABLE OF CONTENTS General Narrative........................................................

1 Chain of Custody and Supporting Documentation.....

5 Data Review Qualifier Definitions.................................

10 Radiological Analysis....................................................

12 Sample Data Summary...........................................

32 Quality Control Data...............................................

76

General Narrative Page 1 of 85

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 183412 SDG: MSR#07-0135 April 06, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on April 03, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 183412001 183412002 183412003 183412004 183412005 183412006 183412007 183412008 183412009 183412010 183412011 183412012 183412013 183412014 183412015 183412016 183412017 183412018 183412019 183412020 Sample Description 9302-0000-001F 9302-0000-002F 9302-0000-003F 9302-0000-004F 9302-0000-005F 9302-0000-006F 9302-0000-007F 9302-0000-008F 9302-0000-009F 9302-0000-01OF 9302-0000-01 IF 9302-0000-012F 9302-0000-013F 9302-0000-013FS 9302-0000-014F 9302-0000-015F 9302-0000-015FS 9302-0000-016B 9302-0000-017B 9302-0000-018B Items of Note There are no items to note.

GEL Laboratories Kfige 2 P(9jBc50712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.555.8171 F843.766.1178 www.gal~com

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Eighteen soil samples were analyzed for FSSGAM and two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl

ýJones Project Manager GEL Laboratories Kge 3 P 1 P";712 Charleston, SC 29417 2040SavageRoad Charleston, SC29407 P843.556.8171 F843.765.1178 www.gol~com

List of current GEL Certifications as of 06 April 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01 151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 Page 4 of 85

Chain of Custody and Supporting Documentation Page 5 of 85

C 00 Connecticut Yankee Atomic Power Company Chain of Custody FormN 362 Injiun Hollow Road, East Hampton, CT 06424 No. 2007-00093 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories C.ode 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority:[] 30 D. E] 15 D. Z] 7 D.

t.

Other:

D

.-d Q

Sample Designation Date Time Comment, Preservation Lab Sample ID 9302-0000-001F 3/2q/07 1407 TS G

BP X

9302-0000-002F 3/29/07 1410 TS G

BP X

9302-0000-003F 3/29/07 1413 TS G

BP X

9302-0000-004F 3/29/07 1415 TS G

BP X

9302-0000-005F 3/29/07 1417 TS G

BP X

9302-0000.-006F 3/29/07 1418 TS G

BP X

9302-0000-007F 3/29/07.

.1421 TS G

BP X

9302-0000-008F 3/29/07 1425 TS G

BP X

9302-0000-009F 3/29/07 1428 TS G

BP X

9302-0000-01OF 3/29/07-1434 TS G

BP X

9302-0000-0t1F 3/29/07 1438 TS G

BP X

NOTES: PO #: 002332 MSR #: 07-0135 Z

LTP QA E] Radwaste QA F] Non QA Samples Shipped Via:

Internal Container ED Fed Ex Temp.:. 1_. Deg. C E]uPs 1"] Hand Custody Sealed?

1) Reli uis Date/Time
2) Received By Date/Time Custody Seal Intact?

3 /,L2o/o7

-1",

3 Q-7 930

[] Other

3) Relinquishet By Date/Time
4) Received By Date/Time YBg N O Bill ofRLading #
5) Relinquished By Date/Time
6) Received By Date/Time

0 00 Connecticut Yankee Atomic Power Company Chain of Custody Form 362 Injun Hollow Road, East Hampton, CT 06424 No. 2007 00094 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested.

Lab UseOnly Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924.

Media Sample:

Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage.Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: [] 30 D. F] 15 D. Z 7 D.

Other:

Sample Designation Date Time W

C Comment, Preservation Lab Sample ID 9302-0000-012F 3/29/07 1441 TS G

BP X

9302-0000-013F 3/29/07 1446 TS G

BP X

9302-0000-013FS 3/29/07 1446 TS G

BP X

9302-0000-014F 3/29/07 1449 TS G

BP X

9302-0000-015F 3/29/07 1452 TS G

BP X

9302-0000-015FS 3/29/07 1452 TS G

BP X

9302-0000-016B 3/29/07 1454 TS G

BP X

9302-0000-017B 3/29/07 1456 TS G

BP X

9302-0000-018B 3/29/07 1503 TS G

BP X

NOTES: PO #: 002332 MSR #: 07-0135 Z

LTP QA

- Radwaste QA El Non QA Samples Shipped Via:

Internal Container

[

Fed Ex Temp.: 1 -7 Deg. C EUPS

_--1 Hand Custody Sealed?

1) Relinq Date/Time
2) Received By Date/Time Custody Seal Intact?

Y( Other

3) Relinquished By Date/Time
4) Received By Date/Time YV IN 0 Bill of Lading #
5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee Statementof Work for Analytical Lab:Services Figure 1. Sample Check-in List.

Date/Time Received:

LI -3 "-7 O

SDG#:

Work Order Number:

[

t-.

  • Shipping CdhtaierID-7*I-

.95*5- °3.C.hainofCustody#

I.

Custody Seals o1i shipping container intact?.

2.

Custody Seals dated and signed?

" 3.

Chain-of-Custody record present?

4.

Cooler temperature 5..

Vermiculite/packing materials-is:

6.?

H umber of samples in shipping container:

7.

Sample holding times exceeded?

Cy-lSC;-SOW-00l Loop-? -

y7yDcIf3 -QW~7 -W09 f

-yes. W,4 'iofJI

Yes, N4o[J Yes q:~ wz o Wet ( I Dry Yes [

Nok

10.

Were any anomalies identified in sample receipt?

11.

Description of anomalies (include sample numbers):.

-Yes [ I No Sample CustodianLaboratory.

Telephoned to:

5~-

Or vp*

0 w-B De:

'-c/-3O-0 T3 Page 8 of 85

SAMPLE RECEIPT & REVIEW FORM PM use only Client: (Y i'

c*-i'ci)- yc--I4/-.

SDG/ARCOC/Work Order:

I *3'--.

Date Received:

L -.-

(>-)

PM(A) Review (ensure non-conforming items are resolved prior to signing):

Received By:

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items) 1Shippin containersreceived Circle Applicable:, scals broken damaged container leaking container other (describe) intact and :sealed?,

Samples requiring cold Circle Coolant #

ice bags blue ice dry ice none other describe) 2 preservation within (4 +/- 2 C)?

./"7eo Record preservation method.

Chain of.custody.documents included with shipment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe)

  • sealed?__m 5 Samples requiring chemical Sample ID's, containers affected.and observed pH:

preservation at proper pH?

VOA vials free of headspace Sample ID's and containers affected:

(defined as <, 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver.to VOA laboratory)

Samples received within holding Id's and tests affected:

8*

time?

Sample ID's on COC match ID's Sample ID's and. containers affected:

9 on bottles?

Date & time on COC match date Samiple ID's affected:

to

& time on bottles? *__

Number of containers received Sample ID's affected:

11 1 11 match number indicated on COC?

COC form is properly signed in relinquished/received sections?

___1 14 Air Bill,Tracking #'s, &

Additional Comments "U RSO RAD Receipt #

Suspected Hazard Information 1 > x2 area background is observed onsamples identified as "non-Sr regulated/non-radioactive", contact the Radiation Safety group for further 99*

investigation.

A Radological Classification?

Maximum Counts Observed*:

0LY:

B PCB Regulated?

Shipped as Vtu H

tazaraous Hazard Class Shipped:

C Material? If yes, contact Waste UN#:

C DReMgulated as a Foreign Soila

-t-on PM (pr PM rev' w 4,azard classification:

Initials Dl:

60 0

Data Review Qualifier Definitions Page 10 of 85

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories Page I rPqx_71 2 Charieston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.555.8171 F843.765.1178 www.gel.com

RADIOLOGICAL ANALYSIS Page 12 of 85

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 183412 Method/Analysis Information Product:

AIphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 622161 622158 622157 Sample ID 183412001 183412015 1201307621 1201307622 1201307623 1201307624 Client ID 9302-0000-001 F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP) 183412001(9302-0000-001 F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 15.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 13 of 85

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 14 of 85

Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 622162 622158 622157 Sample ID 183412001 183412015 1201307625 1201307626 1201307627 1201307628 Client ID 9302-0000-001 F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP) 183412001(9302-0000-001F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 15.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Page 15 of 85

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-I 1-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

622164 Prep Batch Number:

622158 Dry Soil Prep GL-RAD-A-021 Batch Number:

622157 Page 16 of 85

Sample ID Client ID 183412001 9302-0000-OOIF 183412015 9302-0000-014F 1201307629 Method Blank (MB) 1201307630 183412001(9302-0000-001F) Sample Duplicate (DUP) 1201307631 183412001(9302-0000-001F) Matrix Spike (MS) 1201307632 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from Page 17 of 85

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 622283 622157 Page 18 of 85

Sample ID 183412001 183412002 183412003 183412004 183412005 183412006 183412007 183412008 183412009 183412010 183412011 183412012 183412013 183412014 183412015 183412016 183412017 183412018 183412019 183412020 1201307874 1201307875 1201307876 Client ID 9302-0000-001F 9302-0000-002F 9302-0000-003F 9302-0000-004F 9302-0000-005F 9302-0000-006F 9302-0000-007F 9302-0000-008F 9302-0000-009F 9302-0000-01OF 9302-0000-011F 9302-0000-012F 9302-0000-013F 9302-0000-013FS 9302-0000-014F 9302-0000-015F 9302-0000-015FS 9302-0000-016B 9302-0000-017B 9302-0000-018B Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

Page 19 of 85

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 183412013 (9302-0000-013F) was recounted due to a peak shift.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Page 20 of 85

Qualifier U'

Reason Analyte Data rejected due to low abundance.

Bismuth-212 Cesium-134 Sample 183412003 183412004 183412008 183412013 1201307875 183412009 183412010 183412011 183412012 183412013 183412014 183412019 183412016 183412012 183412010 UI Datar rejected due to interference.

Europium-155 Manganese-54 Method/Analysis Information Product:

Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 622197 622158 622157 Page 21 of 85

Sample ID Client ID 183412001 9302-0000-O0IF 183412015 9302-0000-014F 1201307712 Method Blank (MB) 1201307713 183412001(9302-0000-00IF) Sample Duplicate (DUP) 1201307714 183412001(9302-0000-OO1F) Matrix Spike (MS) 1201307715 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Page 22 of 85

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

Analytical Batch Number:

Sample ID 183412001 183412015 1201307744 1201307745 1201307746 1201307747 DOE EML HASL-300, Tc-02-RC Modified 622208 Client ID 9302-0000-001 F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP) 183412001(9302-0000-001 F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 23 of 85

Ouality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

622203 Prep Batch Number:

622158 Dry Soil Prep GL-RAD-A-021 Batch Number:

622157 Page 24 of 85

Sample ID 183412001 183412015 1201307729 1201307730 1201307731 1201307732 Client ID 9302-0000-001F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001F) Sample Duplicate (DUP) 183412001(9302-0000-00 IF) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 4.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 25 of 85

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 622207 622158 622157 Sample ID 183412001 183412015 1201307739 1201307740 1201307741 1201307742 Client ID 9302-0000-001 F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP) 183412001(9302-0000-OOIF) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Page 26 of 85

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method:

EPA 906.0 Modified Analytical Batch Number:

622513 Page 27 of 85

Sample ID Client ID 183412001 9302-0000-O0IF 183412015 9302-0000-014F 1201308338 Method Blank (MB) 1201308339 183412001(9302-0000-001 F) Sample Duplicate (DUP) 1201308340 183412001(9302-0000-001F) Matrix Spike (MS) 1201308341 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 28 of 85

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AII,FSS Analytical Method:

Analytical Batch Number:

Sample ID 183412001 183412015 1201308342 1201308343 1201308344 1201308345 EPA EERF C-01 Modified 622514 Client ID 9302-0000-OO1F 9302-0000-014F Method Blank (MB) 183412001(9302-0000-001 F) Sample Duplicate (DUP) 183412001(9302-0000-001F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 29 of 85

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 183412001 (9302-0000-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to spectral interference. Samples 1201308343 (9302-0000-001F) and 183412001 (9302-0000-001F) were recounted due to the quench number being outside the calibration range.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Page 30 of 85

V

/

Reviewer/Date:

" 60

///

Page 31 of 85

SAMPLE DATA

SUMMARY

Page 32 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-0135 GEL Work Order: 183412 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 33 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 10, 2007 Client Sample ID:

9302-0000-00IF Project:

YANK01204 Sample ID:

183412001 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

29-MAR-07 Receive Date:

03-APR-07 Collector:

Client Moisture:

3.52%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.0363 Curium-242 U

0.00 Curium-243/244 U

0.00 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.0306 Plutonium-239/240 U

0.00123 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

0.245 Rad Gamma Spec Analysis

+/-0.0675

+/-0.066

+/-0.064 0.00 +/-0.0677 0.00

+/-0.066 0.00

+/-0.064 0.0885 0.0913 0.0885 0.178 0.193 14.7

+/-0.0826 0.0476 +/-0.0827

+/-0.0666 0.055 +/-0.0666

+/-8.37 7.02

+/-8.37 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U

Bismuth-212 U

Bismuth-214 Cesium-134 U

Cesium-137 U

Cobalt-60 U

Europium-152 U

Europium-154 U -

Europium-155 U

Lead-212 Lead-214 Manganese-54 U

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U

Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.564 0.0306 0.259 0.374 0.00426 0.0109 0.00563 0.030 0.00565

-0.0141 0.431 0.487 0.00555 0.00315 9.46 0.374 0.00418 0.126

+/-0.160

+/-0.112

+/-0.246

+/-0.0771

+/-0.021

+/-0.0293

+/-0.0195

+/-0.0674

+/-0.0602

+/-0.0565

+/-0.0585

+/-0.0724

+/-0.0193

+/-0.0185

+/-0.980

+/-0.0771

+/-0.0175

+/-0.0346 0.0591 0.0954 0.159 0.0307 0.0188 0.0194 0.0171 0.0443 0.0503 0.0517 0.0268 0.0318 0.0174 0.016 0.142 0.0307 0.0158 0.0156

+/-0.160

+/-0.112

+/-0.246

+/-0.0771

+/-0.021

+/-0.0293

+/-0.0195

+/-0.0674

+/-0.0602

+/-0.0565

+/-0.0585

+/-0.0724

+/-0.0193

+/-0.0185

+/-0.980

+/-0.0771

+/-0.0175

+/-0.0346 0.118 0.191 0.318 0.0614 0.0377 0.0388 0.0341 0.0885 0.101 0.103 0.0535 0.0635 0.0348 0.0319 0.285 0.0614 0.0316 0.0313 0.0442 2.18 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXJ1 04/05/07 0822 622161 1

BXJ1 04/05/07 0818 622162 2

BXJI 04/06/07 0937 622164 3

MJHI 04/04/07 1328 622283 4

KSDI 04/06/07 1038 622197 5

AXD2 04/04/07 1932 622513 6

0.00422

+/-0.0224 0.0193 +/-0.0224 0.324

+/-1.17 0.940

+/-1.17 Page 34 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

9302-0000-OO1F 183412001 Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AllFSS Carbon-14 U

-0.0288 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-30.3 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

1.97 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.00684

+/-0.0997 0.0842 +/-0.0997

+/-24.0 18.0

+/-24.0

+/-6.68 5.55

+/-6.68

+/-0.186 0.156

+/-0.186 0.172 37.8 11.5 0.332 pCi/g pCi/g pCi/g pCi/g AXD2 04/09/07 1611 622514 7

MXP1 04/06/07 0811 622203 9

MXPI 04/06/07 1329 622207 10 MXP1 04/08/07 2246 622208 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300, Pu-I -RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-I, Modified 10 DOE RESL Ni-l, Modified II DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Strontium Carrier Iron-59 Tracer Nickel Carrier Technetium-99m Tracer Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 78 74 78 71 76 81 90 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

Page 35 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

9302-0000-001F 183412001 Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 36 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-002F 183412002 TS 29-MAR-07 03-APR-07 Client 4.74%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.475

+/-0.227 Americium-241 U

0.0232

+/-0.0519 Bismuth-212 U

0.506

+/-0.319 Bismuth-214 0.409

+/-0.127 Cesium-134 U

0.0605

+/-0.0492 Cesium-137 U

0.0431

+/-0.0356 Cobalt-60 U

0.00359

+/-0.0406 Europium-152 U -0.00612

+/-0.0897 Europium-154 U

0.00504

+/-0.103 Europium-155 U

0.0636

+/-0.0889 Lead-212 0.515

+/-0.0809 Lead-214 0.427

+/-0.116 Manganese-54 U

0.0103

+/-0.0338 Niobium-94 U

-0.0151

+/-0.0367 Potassium-40 9.45

+/-1.21 Radium-226 0.409

+/-0.127 Silver-108m U

0.0121

+/-0.0282 Thallium-208 0.205

+/-0.0736 0.101 0.0441 0.274 0.0515 0.034 0.028 0.0296 0.0731 0.0876 0.0655 0.0382 0.0491 0.0303 0.0256 0.282 0.0515 0.0257 0.0296

+/-0.227

+/-0.0519

+/-0.319

+/-0.127

+/-0.0492

+/-0.0356

+/-0.0406

+/-0.0897

+/-0.103

+/-0.0889

+/-0.0809

+/-0.116

+/-0.0338

+/-0.0367

+1-1.21

+/-0.127

+/-0.0282

+/-0.0736 0.202 0.0882 0.548 0.103 0.068 0.0559 0.0593 0.146 0.175 0.131 0.0764 0.0982 0.0605 0.0512 0.563 0.103 0.0513 0.0592 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1329 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 37 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton,.Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-002F Project:

YANK01204 Sample ID:

183412002 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 38 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-003F 183412003 TS 29-MAR-07 03-APR-07 Client 6.87%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.670

+/-0.229 Americium-241 U -0.00669

+/-0.0465 Bismuth-212 U1 0.00

+/-0.474 Bismuth-214 0.518

+/-0.142 Cesium-134 U

0.0142

+/-0.0346 Cesium-137 U

0.0411

+/-0.0587 Cobalt-60 U

-0.0187

+/-0.0399 Europium-152 U-0.000722

+/-0.0986 Europium-154 U

-0.0602

+/-0.102 Europium-155 U

0.0727

+/-0.0662 Lead-212 0.636

+/-0.0928 Lead-214 0.495

+/-0.130 Manganese-54 U

-0.0106

+/-0.0396 Niobium-94 U

0.00641

+/-0.0298 Potassium-40 10.4

+/-1.30 Radium-226 0.518

+/-0.142 Silver-108m U -0.00581

+/-0.0347 Thallium-208 0.205

+/-0.0582 0.0919 0.0364 0.305 0.0439 0.0314 0.031 0.0306 0.0652 0.0764 0.0606 0.037 0.0476 0.0333 0.0266 0.276 0.0439 0.0254 0.0296

+/-0.229

+/-0.0465

+/-0.474

+/-0.142

+/-0.0346

+/-0.0587

+/-0.0399

+/-0.0986

+/-0.102

+/-0.0662

+/-0.0928

+/-0.130

+/-0.0396

+/-0.0298

+/-1.30

+/-0.142

+/-0.0347

+/-0.0582 0.184 0.0727 0.610 0.0877 0.0627 0.062 0.0611 0.130 0.153 0.121 0.074 0.0952 0.0666 0.0532 0.552 0.0877 0.0507 0.0591 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 04/04/07 1330 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 39 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-003F Proiect:

YANK01204 Sample ID:

183412003 Client ID:

YANKoo0 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 40 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-004F 183412004 TS 29-MAR-07 03-APR-07 Client 4.72%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.781

+/-0.153 Americium-241 U

0.0784

+/-0.0673 Bismuth-212 UI 0.00

+/-0.174 Bismuth-214 0.455

+/-0.070 Cesium-134 U

0.0222

+/-0.0203 Cesium-137 U -0.00537

+/-0.0191 Cobalt-60 U -0.00714

+/-0.0159 Europium-152 U 0.000315

+/-0.0526 Europium-154 U

0.0202

+/-0.0555 Europium-155 U

-0.0053

+/-0.0458 Lead-212 0.580

+/-0.0635 Lead-214 0.571

+/-0.0799 Manganese-54 U

0.0085

+/-0.0151 Niobium-94 U

0.0204

+/-0.0144 Potassium-40 10.3

+/-0.867 Radium-226 0.455

+/-0.070 Silver-108m U -0.00971

+/-0.0134 Thallium-208 0.192

+/-0.0333 0.0464 0.0566 0.140 0.0256 0.0166 0.0138 0.013 0.0351 0.0471 0.0422 0.0219 0.0261 0.0136 0.0133 0.113 0.0256 0.011 0.0117

+/-0.153

+/-0.0673

+/-0.174

+/-0.070

+/-0.0203

+/-0.0191

+/-0.0159

+/-0.0526

+/-0.0555

+/-0.0458

+/-0.0635

+/-0.0799

+/-0.0151

+/-0.0144

+/-0.867

+/-0.070

+/-0.0134

+/-0.0333 0.0928 0.113 0.280 0.0511 0.0331 0.0275 0.0261 0.0702 0.0941 0.0844 0.0438 0.0521 0.0272 0.0265 0.226 0.0511 0.0221 0.0234 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1331 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 41 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-004F Proiect:

YANK01204 Sample ID:

183412004 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 42 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-005F 183412005 TS 29-MAR-07 03-APR-07 Client 4.08%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rod Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.831

+/-0.217 Americium-241 U

0.00663

+/-0.0418 Bismuth-212 U

0.339

+/-0.279 Bismuth-214 0.566

+/-0.124 Cesium-134 U

0.0545

+/-0.0398 Cesium-137 U

0.00227

+/-0.0356 Cobalt-60 U

-0.0124

+/-0.0295 Europium-152 U

0.025

+/-0.0787 Europium-154 U

-0.0109

+/-0.0887 Europium-155 U

0.0794

+/-0.0895 Lead-212 0.683

+/-0.103 Lead-214 0.637

+/-0.124 Manganese-54 U

0.0233

+/-0.026 Niobium-94 U

0.0108

+/-0.0283 Potassium-40 10.4

+/-1.18 Radium-226 0.566

+/-0.124 Silver-108m U

-0.0187

+/-0.0231 Thallium-208 0.222

+/-0.0578 0.0742 0.0349 0.245 0.0467 0.0348 0.0264 0.0231 0.0632 0.0698 0.0563 0.0339 0.0447 0.0247 0.0248 0.231 0.0467 0.0189 0.0227

+/-0.217

+/-0.0418

+/-0.279

+/-0.124

+/-0.0398

+/-0.0356

+/-0.0295

+/-0.0787

+/-0.0887

+/-0.0895

+/-0.103

+/-0.124

+/-0.026

+/-0.0283

+/-1.18

+/-0.124

+/-0.0231

+/-0.0578 0.148 0.0698 0.490 0.0933 0.0695 0.0528 0.0461 0.126 0.140 0.113 0.0677 0.0894 0.0494 0.0496 0.462 0.0933 0.0378 0.0453 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 04/04/07 1404 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound Result is less than value reported Page 43 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-005F Project:

YANK01204 Sample ID:

183412005 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 44 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April-10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-006F 183412006 TS 29-MAR-07 03-APR-07 Client 6.07%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.418 U

0.00183 U

0.341 0.386 U

0.0317 U

0.0148 U

0.0212 U

0.0521 U

-0.0607 U

0.0542 0.516 0.476 U

-0.0026 U

0.00359 9.77 0.386 U

-0.0113 0.158

+/-0.193

+/-0.0868

+/-0.259

+/-0.0914

+/-0.0255

+/-0.0235

+/-0.0237

+/-0.086

+/-0.0733

+/-0.0601

+/-0.0705

+/-0.096

+/-0.0224

+/-0.0189

+/-1.01

+/-0.0914

+/-0.0186

+/-0.0419 0.0682 0.072 0.175 0.0357 0.0239 0.0209 0.0219 0.054 0.0568 0.056 0.0291 0.036 0.0191 0.0168 0.165 0.0357 0.0158 0.0186

+/-0.193

+/-0.0868

+/-0.259

+/-0.0914

+/-0.0255

+/-0.0235

+/-0.0237

+/-0.086

+/-0.0733

+/-0.0601

+/-0.0705

+/-0.096

+/-0.0224

+/-0.0189

+/-1.01

+/-0.0914

+/-0.0186

+/-0.0419 0.136 0.144 0.350 0.0713 0.0477 0.0417 0.0438 0.108 0.113 0.112 0.0582 0.0719 0.0382 0.0336 0.330 0.0713 0.0316 0.0372 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1440 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 45 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date;:. April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-006F Proiect:

YANK01204 Sample ID:

183412006 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 46 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-007F 183412007 TS 29-MAR-07 03-APR-07 Client 4.91%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.770

+/-0.246 Americium-241 U

0.0257

+/-0.055 Bismuth-212 U

0.372

+/-0.333 Bismuth-214 0.418

+/-0.115 Cesium-134 U

0.0142

+/-0.0415 Cesium-137 U

0.0496

+/-0.0452 Cobalt-60 U

0.0159

+/-0.0355 Europium-152 U

0.0382

+/-0.0963 Europium-154 U

0.0538

+/-0.111 Europium-155 U

0.0186

+/-0.0816 Lead-212 0.532

+/-0.0887 Lead-214 0.533

+/-0.143 Manganese-54 U

-0.0223

+/-0.0356 Niobium-94 U

0.00976

+/-0.0344 Potassium-40 11.2

+/-1.33 Radium-226 0.418

+/-0.115 Silver-108m U

-0.0125

+/-0.0307 Thallium-208 0.161

+/-0.064 0.104 0.0459 0.301 0.057 0.0372 0.0308 0.0314 0.0731 0.0978 0.0742 0.0415 0.0522 0.0294 0.0296 0.267 0.057 0.0261 0.0284

+/-0.246

+/-0.055

+/-0.333

+/-0.115

+/-0,0415

+/-0.0452

+/-0.0355

+/-0.0963

+/-0.111

+/-0.0816

+/-0.0887

+/-0.143

+/-0.0356

+/-0.0344

+/-1.33

+/-0.115

+/-0.0307

+/-0.064 0.208 0.0918 0.602 0.114 0.0744 0.0616 0.0627 0.146 0.196 0.148 0.083 0.104 0.0588 0.0593 0.534 0.114 0.0522 0.0567 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1532 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 47 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd a

East Hampton, Connecticut 06424 Report Date:

April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-007F Proiect:

YANK01204 Sample ID:

183412007 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC(MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 48 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-008F 183412008 TS 29-MAR-07 03-APR-07 Client 6.26%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.540

+/-0.295 Americium-241 U

0.018

+/-0.0454 Bismuth-212 UI 0.00

+/-0.407 Bismuth-214 0.583

+/-0.132 Cesium-134 U

0.0492

+/-0.0368 Cesium-137 U -0.00161

+/-0.0331 Cobalt-60 U

-0.0363

+/-0.0353 Europium-152 U

0.0173

+/-0.0869 Europium-154 U

-0.0793

+/-0.109 Europium-155 U

0.057

+/-0.0662 Lead-212 0.700

+/-0.0959 Lead-214 0.558

+/-0.116 Manganese-54 U

0.00883

+/-0.0341 Niobium-94 U

-0.0141

+/-0.0331 Potassium-40 11.0

+/-1.34 Radium-226 0.583

+/-0.132 Silver-108m U

-0.0053

+/-0.0259 Thallium-208 0.218

+/-0.0549 0.105 0.0369 0.275 0.0504 0.0341 0.029 0.0235 0.0676 0.0801 0.0606 0.0336 0.0473 0.0304 0.0279 0.266 0.0504 0.0221 0.0297

+/-0.295

+/-0.0454

+/-0.407

+/-0.132

+/-0.0368

+/-0.0331

+/-0.0353

+/-0.0869

+/-0.109

+/-0.0662

+/-0.0959

+/-0.116

+/-0.0341

+/-0.0331

+/-1.34

+/-0.132

+/-0.0259

+/-0.0549 0.211 0.0738 0.550 0.101 0.0682 0.058 0.047 0.135 0.160 0.121 0.0671 0.0945 0.0607 0.0557 0.531 0.101 0.0441 0.0594 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1533 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 49 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-008F Project:

YANK01204 Sample ID:

183412008 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 50 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:. April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-009F 183412009 TS 29-MAR-07 03-APR-07 Client 4.33%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.872

+/-0.146 Americium-241 U

0.130

+/-0.0857 Bismuth-212 0.592

+/-0.200 Bismuth-214 0.784

+/-0.0916 Cesium-134 UI 0.00

+/-0.0231 Cesium-137 U

0.017

+/-0.0155 Cobalt-60 U 0.000646

+/-0.0152 Europium-152 U

-0.0466

+/-0.0458 Europium-154 U

-0.0729

+/-0.0494 Europium-155 U

0.0727

+/-0.0659 Lead-212 0.793

+/-0.0748 Lead-214 0.811

+/-0.0861 Manganese-54 U

0.024

+/-0.0186 Niobium-94 U 0.000961

+/-0.0143 Potassium-40 13.8

+/-1.08 Radium-226 0.784

+/-0.0916 Silver-108m U -0.00199

+/-0.0125 Thallium-208 0.267

+/-0.0358 0.0429 0.0721 0.0963 0.0224 0.0159 0.0137 0.0127 0.0317 0.0373 0.039 0.0189 0.0228 0.0121 0.0114 0.105 0.0224 0.0109 0.0118

+/-0.146

+/-0.0857

+/-0.200

+/-0.0916

+/-0.0231

+/-0.0155

+/-0.0152

+/-0.0458

+/-0.0494

+/-0.0659

+/-0.0748

+/-0.0861

+/-0.0186

+/-0.0143

+/-1.08

+/-0.0916

+/-0.0125

+/-0.0358 0.0858 0.144 0.193 0.0447 0.0318 0.0274 0.0254 0.0633 0.0746 0.078 0.0379 0.0455 0.0243 0.0228 0.211 0.0447 0.0218 0.0236 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1635 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 51 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:.:April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-009F Proiect:

YANK01204 Sample ID:

183412009 Client ID:

YANKO0l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 52 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-01OF 183412010 TS 29-MAR-07 03-APR-07 Client 5.25%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01

+/-0.153 Americium-241 U

0.0248

+/-0.0388 Bismuth-212 0.657

+/-0.153 Bismuth-214 0.777

+/-0.0885 Cesium-134 U1 0.00

+/-0.0186 Cesium-137 0.215

+/-0,0286 Cobalt-60 0.110

+/-0,0251 Europium-152 U

-0.0362

+/-0,0409 Europium-154 U

-0.0206

+/-0,0399 Europium-155 U

0.0586

+/-0.0447 Lead-212 0.962

+/-0.0793 Lead-214 0.932

+/-0.090 Manganese-54 UI 0.00

+/-0.0179 Niobium-94 U5.450E-05

+/-0.0106 Potassium-40 16.1

+/-1.09 Radium-226 0.777

+/-0.0885 Silver-108m U -0.00251

+/-0.0103 Thallium-208 0.292

+/-0.0366 0.0347 0.0382 0.0704 0.0183 0.0124 0.0103 0.00947 0.0259 0.0302 0.0299 0.0155 0.0188 0.00948 0.00902 0.0829 0.0183 0.00874 0.00885

+/-0.153

+/-0.0388

+/-0.153

+/-0.0885

+/-0.0186

+/-0.0286

+/-0.0251

+/-0.0409

+/-0.0399

+/-0.0447

+/-0.0793

+/-0.090

+/-0.0179

+/-0.0106

+/-1.09

+/-0.0885

+/-0.0103

+/-0.0366 0.0694 0.0763 0.141 0.0366 0.0247 0.0205 0.0189 0.0518 0.0603 0.0599 0.031 0.0376 0.019 0.018 0.166 0.0366 0.0175 0.0177 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1637 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 53 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-01OF Project:

YANK01204 Sample ID:

183412010 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 54 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton; Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 10, 2007 Client Sample ID:

9302-0000-011F Project:

YANK01204 Sample ID:

183412011 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

29-MAR-07 Receive Date:

03-APR-07 Collector:

Client Moisture:"

4.88%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.981

+/-0.172 Americium-241 U

0.0216

+/-0.0318 Bismuth-212 0.587

+/-0.266 Bismuth-214 0.784

+/-0.109 Cesium-134 UT 0.00

+/-0.0272 Cesium-137 0.0319

+/-0.0262 Cobalt-60 U

0.014

+/-0.018 Europium-152 U

0.00967

+/-0.0522 Europium-154 U

0.016

+/-0.0597 Europium-155 U

0.0773

+/-0.0553 Lead-212 0.946

+/-0.0979 Lead-214 0.894

+/-0.103 Manganese-54 U

-0.0123

+/-0.020 Niobium-94 U -0.00659

+/-0.0183 Potassium-40 14.8

+/-1.09 Radium-226 0.784

+/-0.109 Silver-108m U -0.00473

+/-0.0169 Thallium-208 0.298

+/-0.0442 0.0577 0.0261 0.124 0.0328 0.0201 0.0137 0.0161 0.0423 0.0507 0.0401 0.0229 0.0301 0.0169 0.0152 0.145 0.0328 0.0146 0.0163

+/-0.172

+/-0.0318

+/-0.266

+/-0.109

+/-0.0272

+/-0.0262

+/-0.018

+/-0.0522

+/-0.0597

+/-0.0553

+/-0.0979

+/-0.103

+/-0.020

+/-0.0183

+/-1.09

+/-0.109

+/-0.0169

+/-0.0442 0.115 0.0522 0.247 0.0655 0.0402 0.0274 0.0323 0.0846 0.101 0.0802 0.0458 0.0601 0.0339 0.0304 0.289 0.0655 0.0291 0.0327 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 04/04/07 1748 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Page 55 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-011F Proiect:

YANK01204 Sample ID:

183412011 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 56 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-012F 183412012 TS 29-MAR-07 03-APR-07 Client 8.06%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-I134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.37 U

0.0191 0.936 1.24 U1 0.00 U -0.00412 U

0.0142 U

-0.021 U

-0.0054 UI 0.00 1.26 1,39 U

0.00826 U

0.00347 20.1 1.24 U

0.0147 0.448

+/-0.216

+/-0.0298

+/-0.283

+/-0.137

+/-0.0385

+/-0.0227

+/-0.0196

+/-0.047

+/-0.0637

+/-0.0597

+/-0.124

+/-0.139

+/-0.0264

+/-0.0189

+/-1.42

+/-0.137

+/-0.0158

+/-0.0544 0.0579 0.0238 0.129 0.0294 0.0225 0.017 0.017 0.0378 0.0524 0.035 0.0204 0.0274 0.0161 0.0158 0.133 0.0294 0.0141 0.0155

+/-0.216

+/-0.0298

+/-0.283

+/-0.137

+/-0.0385

+/-0.0227

+/-0.0196

+/-0.047

+/-0.0637

+/-0.0597

+/-0.124

+/-0.139

+/-0.0264

+/-0.0189

+/-1.42

+/-0.137

+/-0.0158

+/-0.0544 0.116 0.0476 0.257 0.0588 0.045 0.034 0.034 0.0755 0.105 0.070 0.0408 0.0547 0.0322 0.0316 0.265 0.0588 0.0282 0.031 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 04/04/07 1749 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 57 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date;: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-012F Project:

YANK01204 Sample ID:

183412012 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 58 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-013F 183412013 TS 29-MAR-07 03-APR-07 Client 7.91%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.11

+/-0.215 Americium-241 U

0.0218

+/-0.0931 Bismuth-212 UI 0.00

+/-0.324 Bismuth-214 0.912

+/-0.145 Cesium-134 UI 0.00

+/-0.0357 Cesium-137 U -0.00362

+/-0.0276 Cobalt-60 U

0.0212

+/-0.0266 Europium-152 U

-0.0485

+/-0.0744 Europium-154 U

-0.0459

+/-0.0792 Europium-155 U

0.0895

+/-0.0662 Lead-212 1.16

+/-0.113 Lead-214 1.01

+/-0.135 Manganese-54 U

0.00376

+/-0.0268 Niobium-94 U

-0.0104

+/-0.0236 Potassium-40 18.6

+/-1.59 Radium-226 0.912

+/-0.145 Silver-108m U

0.00725

+/-0.0204 Thallium-208 0.346

+/-0.0602 0.0706 0.0749 0.233 0.0443 0.0276 0.023 0.0239 0.0541 0.0624 0.0611 0.0301 0.0393 0.0233 0.0191 0.201 0.0443 0.018 0.0197

+/-0.215

+/-0.0931

+/-0.324

+/-0.145

+/-0.0357

+/-0.0276

+/-0.0266

+/-0.0744

+/-0.0792

+/-0.0662

+/-0.113

+/-0.135

+/-0.0268

+/-0.0236

+/-1.59

+/-0.145

+/-0.0204

+/-0.0602 0.141 0.150 0.467 0.0886 0.0551 0.046 0.0478 0.108 0.125 0.122 0.0602 0.0785 0.0466 0.0382 0.401 0.0886 0.0359 0.0393 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/05/07 1617 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 2

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Page 59 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-013F Proiect:

YANK01204 Sample ID:

183412013 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 60 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-013FS 183412014 TS 29-MAR-07 03-APR-07 Client 8.14%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.11

+/-0.184 Americium-241 U

0.0205

+/-0.0274 Bismuth-212 0.681

+/-0.244 Bismuth-214 1.01

+/-0.132 Cesium-134 UI 0.00

+/-0.0404 Cesium-137 U

0.0122

+/-0.0203 Cobalt-60 U-0.000158

+/-0.0223 Europium-152 U

-0.0623

+/-0.0611 Europium-154 U -0.00722

+/-0.0766 Europium-155 U

0.0523

+/-0.0478 Lead-212 1.09

+/-0.106 Lead-214 1.03

+/-0.118 Manganese-54 U

0.0204

+/-0.0235 Niobium-94 U -0.00788

+/-0.0188 Potassium-40 18.0

+/-0.954 Radium-226 1.01

+/-0.132 Silver-108m U -0.00641

+/-0.0163 Thallium-208 0.382

+/-0.0585 0.059 0.024 0.130 0.0277 0.0234 0.0181 0.0186 0.0377 0.0636 0.0361 0.0217 0.0281 0.0184 0.0161 0.149 0.0277 0.0138 0.0156

+/-0.184

+/-0.0274

+/-0.244

+/-0.132

+/-0.0404

+/-0.0203

+/-0.0223

+/-0.0611

+/-0.0766

+/-0.0478

+/-0.106

+/-0.118

+/-0.0235

+/-0.0188

+/-0.954

+/-0.132

+/-0.0163

+/-0.0585 0.118 0.0479 0.259 0.0554 0.0468 0.0362 0.0371 0.0753 0.127 0.0721 0.0433 0.0562 0.0368 0.0322 0.298 0.0554 0.0276 0.0312 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/04/07 1751 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 61 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-013FS Project:

YANK01204 Sample ID:

183412014 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 62 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 Certificate of Analysis

- www.gel.com Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: April 10; 2007 "

Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-014F 183412015 TS 29-MAR-07 03-APR-07 Client 6.65%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

-0 Curium-242 U

0.

Curium-243/244 U

-0.

Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

Plutonium-239/240 U -0.C Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

Rad Gamma Spec Analysis

+/-0.0239

+/-0.0631

+/-0.0202 0.0385 0.0281 0.0385

+/-0.0239

+/-0.0632

+/-0.0203 0.159 0.141 0.159 0.190 0.147 pCi/g pCi/g pCi/g pCi/g pCi/g

+/-0.0606 0.0509 +/-0.0606

+/-0.066 0.0294

+/-0.066 2.38

+/-7.60 6.27

+/-7.61 13.2 pCi/g Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U

Bismuth-212 U

Bismuth-214 Cesium-134 U

Cesium-137 U

Cobalt-60 U -

Europium-152 U

Europium-154 U

Europium-155 U -

Lead-212 Lead-214 Manganese-54 U

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U

Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.634 0.051 0.467 0.519 0.0496 0.00285 0.00464

-0.0455 0.00657 0.00617 0.803 0.668

-0.0215 0.00567 12.9 0.519

-0.0355 0.260

+/-0.321

+/-0.0574

+/-0.425

+/-0.142

+/-0.0738

+/-0.040

+/-0.047

+/-0.107

+/-0.131

+/-0.0812

+/-0.110

+/-0.145

+/-0.0361

+/-0.035

+/-1.42

+/-0.142

+/-0.0318

+/-0.0788 0.118 0.0489 0.309 0.0662 0.0405 0.0342 0.0331 0.0755 0.095 0.0733 0.0435 0.055 0.030 0.030 0.290 0.0662 0.0258 0.0301

+/-0.321

+/-0.0574

+/-0.425

+/-0.142

+/-0.0738

+/-0.040

+/-0.047

+/-0.107

+/-0.131

+/-0.0812

+/-0.110

+/-0.145

+/-0.0361

+/-0.035

+/-1.42

+/-0.142

+/-0.0318

+/-0.0788 0.235 0.0977 0.617 0.132 0.081 0.0683 0.0662 0.151 0.190 0.147 0.0869 0.110 0.0599 0.0599 0.580 0.132 0.0516 0.0603 0.0439 2.24 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXJI 04/05/07 0822 622161 1

BXJI 04/05/07 0818 622162 2

BXJI 04/06/07 0953 622164 3

MJH 1 04/05/07 0904 622283 4

KSDI 04/06/07 1038 622197 5

AXD2 04/04/07 1954 622513 6

-0.0177

+/-0.0199 0.0192 +/-0.0199 1.16

+/-1.33 0.964

+/-1.33 Page 63 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April.10, 2007 Client Sample ID:

Sample ID:

9302-0000-014F 183412015 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 U

-0.0045

+/-0.0971 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

8.92

+/-29.9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

2.30

+/-7.82 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

-0.117

+/-0.186 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0815 +/-0.0971 0.166 21.1

+/-29.9 44.5 6.49

+/-7.82 13.4 0.163

+/-0.186 0.347 pCi/g pCi/g pCi/g pCi/g AXD2 04/06/07 2346 622514 7

MXP1 04/06/07 0828 622203 9

MXPI 04/06/07 1401 622207 10 MXPI 04/08/07 2304 622208 II The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300, Pu-I I-RC Modified 4

EML HASL 300,4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-1, Modified 10 DOE RESL Ni-I, Modified 1I DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Tracer Plutonium-242 Tracer Plutonium-242 Tracer Strontium Carrier Iron-59 Tracer Nickel Carrier Technetium-99m Tracer Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 84 71 85 75 66 71 87 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

Page 64 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-014F Project:

YANK01204 Sample ID:

183412015 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 65 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvsis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-015F 183412016 TS 29-MAR-07 03-APR-07 Client 5.21%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04

+/-0.259 Americium-241 U

0.0111

+/-0.0434 13ismuth-212 U

0.398

+/-0.268 13ismuth-214 0.690

+/-0.116 Cesium-134 UI 0.00

+/-0.0386 Cesium-137 U -0.00324

+/-0.0287 Cobalt-60 U

0.0111

+/-0.0309 Europium-152 U

-0.0198

+/-0.0801 Europium-154 U

0.00845

+/-0.103 Europium-155 U

0.0685

+/-0.0794 Lead-212 0.945

+/-0.121 Lead-214 0.730

+/-0.120 Manganese-54 U -0.00658

+/-0.0276 Niobium-94 U

0.0234

+/-0.0279 Potassium-40 16.4

+/-1.55 Radium-226 0.690

+/-0.116 Silver-108m U -0.00587

+/-0.024 Thallium-208 0.310

+/-0.0646 0.0896 0.0361 0.248 0.0383 0.0262 0.0239 0.0271 0.0573 0.087 0.0586 0.0338 0.0434 0.0236 0.0251 0.191 0.0383 0.0207 0.0224

+/-0.259

+/-0.0434

+/-0.268

+/-0.116

+/-0.0386

+/-0.0287

+/-0.0309

+/-0.0801

+/-0.103

+/-0.0794

+/-0.121

+/-0.120

+/-0.0276

+/-0.0279

+/-1.55

+/-0.116

+/-0.024

+/-0.0646 0.179 0.0722 0.496 0.0766 0.0523 0.0477 0.0541 0.115 0.174 0.117 0.0675 0.0867 0.0472 0.0502 0.382 0.0766 0.0414 0.0447 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/05/07 0906 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 66 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton,-Connetticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-015F Project:

YANK01204 Sample ID:

183412016 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 67 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-015FS 183412017 TS 29-MAR-07 03-APR-07 Client 5.48%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.838 U

-0.0163 0.785 0.664 U

0.048 U -0.00376 U-0.000241 U

0.0839 U

0.0136 U

0.0399 0.975 0.679 U 0.000871 U

-0.0158 15.5 0.664 U

0.00205 0.307

+/-0.254

+/-0.0483

+/-0.349

+/-0.151

+/-0.0509

+/-0.0335

+/-0.0383

+/-0.0804

+/-0.111

+/-0.0687

+/-0.120

+/-0.136

+/-0.0354

+/-0.0326

+/-1.60

+/-0.151

+/-0.0253

+/-0.0636 0.120 0.0399 0.212 0.0479 0.039 0.0273 0.0316 0.0722 0.0935 0.0643 0.0351 0.0453 0.0302 0.0259 0.209 0.0479 0.0223 0.025

+/-0.254

+/-0.0483

+/-0.349

+/-0.151

+/-0.0509

+/-0.0335

+/-0.0383

+/-0.0804

+/-0.111

+/-0.0687

+/-0.120

+/-0.136

+/-0.0354

+/-0.0326

+/-1.60

+/-0.151

+/-0.0253

+/-0.0636 0.240 0.0798 0.425 0.0956 0.078 0.0545 0.0632 0.144 0.187 0.129 0.0701 0.0906 0.0604 0.0518 0.417 0.0956 0.0446 0.050 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/05/07 0907 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 68 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-015FS Proiect:

YANK01204 Sample ID:

183412017 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 69 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April-10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-016B 183412018 TS 29-MAR-07 03-APR-07 Client 6.93%

Proiect:

Client ID:

Vol. Recv.:

YANKO1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.772

+/-0.256 Americium-241 U

0.0448

+/-0.0467 Bismuth-212 0.918

+/-0.418 Bismuth-214 0.578

+/-0.119 Cesium-134 U

0.0386

+/-0.0467 Cesium-137 U

0.0204

+/-0.0312 Cobalt-60 U

0.0352

+/-0.0492 Europium-152 U

-0.0172

+/-0.0914 Europium-154 U

-0.067

+/-0.112 Europium-155 U

0.0287

+/-0.104 Lead-212 0.838

+/-0.108 Lead-214 0.652

+/-0.134 Manganese-54 U -0.00538

+/-0.0371 Niobium-94 U

0.00601

+/-0.0305 Potassium-40 13.5

+/-1.42 Radium-226 0.578

+/-0.119 Silver-108m U

0.0262

+/-0.0293 Thallium-208 0.284

+/-0.0681 0.113 0.0391 0.228 0.0289 0.0389 0.0292 0.037 0.0643 0.0852 0.0598 0.0373 0.0485 0.027 0.0273 0.228 0.0289 0.0271 0.0269

+/-0.256

+/-0.0467

+/-0.418

+/-0.119

+/-0.0467

+/-0.0312

+/-0.0492

+/-0.0914

+/-0.112

+/-0.104

+/-0.108

+/-0.134

+/-0.0371

+/-0.0305

+/-1.42

+/-0.119

+/-0.0293

+/-0.0681 0.225 0.0781 0.456 0.0577 0.0778 0.0584 0.074 0.129 0.170 0.119 0.0745 0.0969 0.054 0.0545 0.456 0.0577 0.0542 0.0538 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 04/05/07 0908 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Page 70 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-016B Proiect:

YANK01204 Sample ID:

183412018 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 71 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis of Analvsis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-017B 183412019 TS 29-MAR-07 03-APR-07 Client 7.82%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.50

+/-0.247 Americium-241 U

0.0377

+/-0.096 Bismuth-212 0.651

+/-0.357 Bismuth-214 1.06

+/-0.133 Cesium-134 UI 0.00

+/-0.0352 Cesium-137 U

0.0205

+/-0.027 Cobalt-60 U 0.000105

+/-0.0223 Europium-152 U

-0.0433

+/-0.0759 Europium-154 U

0.0592

+/-0.0899 Europium-155 U

0.0868

+/-0.0681 Lead-212 1.31

+/-0.119 Lead-214 1.27

+/-0.142 Manganese-54 U

0.0171

+/-0.0248 Niobium-94 U

0.0164

+/-0.0216 Potassium-40 20.9

+/-1.60 Radium-226 1.06

+/-0.133 Silver-108m U -0.00939

+/-0.0201 Thallium-208 0.340

+/-0.0549 0.0632 0.0748 0.140 0.0331 0.0234 0.0207 0.0189 0.0514 0.0603 0.0626 0.0309 0.0348 0.0192 0.0188 0.162 0.0331 0.0166 0.0187

+/-0.247

+/-0.096

+/-0.357

+/-0.133

+/-0.0352

+/-0.027

+/-0.0223

+/-0.0759

+/-0.0899

+/-0.0681

+/-0.119

+/-0.142

+/-0.0248

+/-0.0216

+/-1.60

+/-0.133

+/-0.0201

+/-0.0549 0.126 0.150 0.279 0.0662 0.0468 0.0413 0.0378 0.103 0.120 0.125 0.0618 0.0696 0.0384 0.0377 0.323 0.0662 0.0331 0.0374 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 04/05/07 0909 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/03/07 1030 622157 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound Result is less than value reported Page 72 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East '-lampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-017B Project:

YANK01204 Sample ID:

183412019 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 73 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 -

Mr. lack McCarthy Soils PO# 002332 Report Date: April 10, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9302-0000-018B 183412020 TS 29-MAR-07 03-APR-07 Client 4%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.664

+/-0.159 Americium-241 U

-0.025

+/-0.0982 Bismuth-212 0.312

+/-0.244 Bismuth-214 0.375

+/-0.0868 Cesium-134 U -0.00352

+/-0.022 Cesium-137 U -0.00368

+/-0.020 Cobalt-60 U -0.00616

+/-0.0211 Europium-152 U

-0.0232

+/-0.0541 Europium-154 U

-0.0114

+/-0.064 Europium-155 U -0.00743

+/-0.0648 Lead-212 0.461

+/-0.0576 Lead-214 0.455

+/-0.0832 Manganese-54 U -0.00437

+/-0.019 Niobium-94 U

0.011

+/-0.0201 Potassium-40 9.33

+/-0.971 Radium-226 0.375

+/-0.0868 Silver-108m U

0.00565

+/-0.0168 Thallium-208 0.147

+/-0.037 0.0551 0.081 0.107 0.0322 0.0184 0.0169 0.017 0.0408 0.053 0.0521 0.0233 0.0322 0.0164 0.0178 0.153 0.0322 0.0152 0.0168

+/-0.159

+/-0.0982

+/-0.244

+/-0.0868

+/-0.022

+/-0.020

+/-0.0211

+/-0.0541

+/-0.064

+/-0,0648

+/-0.0576

+/-0.0832

+/-0.019

+/-0.0201

+/-0.971

+/-0.0868

+/-0.0168

+/-0.037 0.110 0.162 0.213 0.0644 0.0369 0.0337 0.034 0.0816 0.106 0.104 0.0466 0.0643 0.0327 0.0356 0.306 0.0644 0.0304 0.0335 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 04/05/07 0914 622283 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 04/03/07 1030 622157 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

    • Analyte is a surrogate compound Result is less than value reported Page 74 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-018B Project:

YANK01204 Sample ID:

183412020 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 75 of 85

I QUALITY CONTROL DATA I

Page 76 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: April 10, 2007 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

183412 Parmname Rad Alpha Spec Batch 622161 NOM Samnle Oual OC U~nits RPD%

REC%

Range Anlst Date Time Sample Qual QC Units RPD%

REC%

Ranpe Anist Date Timev QC1201307622 Americium-241 Curium-242 Curium-243/244 QC 1201307624 Americium-241 Curium-242 Curium-243/244 QC1201307621 Americium-241 183412001 DUP U

0.0363 Uncert:

+/-0.0675 TPU:

+/-0.0677 U

0.00 Uncert:

+/-0.066 TPU:

+/-0.066 U

0.00 Uncert:

+/-0.064 TPU:

+/-0.064 LCS MB 13.3 Uncert:

TPU:

Uncert:

TPU:

15.9 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0367

+/-0.0624

+/-0.0625 U

0.0243

+/-0.0644

+/-0.0645 U

0.00

+/-0.0607

+/-0.0607 14.0

+/-1.35

+/-2.31 U

0.0678

+/-0.0939

+/-0.0944 15.3

+/-1.40

+/-2.49 U

-0.029

+/-0.0576

+/-0.0578 U

0.00

+/-0.0582

+/-0.0582 U

-0.00706

+/-0.0138

+/-0.0139 pCi/g 36500 pCi/g 200 pCi/g 0

pCi/g Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (0% - 100%) BXJ1 04/05/07 08:22 (0% - 100%)

(0% - 100%)

105 (75%-125%)

96 (75%-125%)

Curium-243/244 QCI1201307623 Americium-241 183412001 MS Curium-242 13.6 Uncert:

TPU:

Uncert:

TPU:

16.3 Uncert:

TPU:

U 0.0363

+/-0.0675

+/-0.0677 U

0.00

+/-0.066

+/-0.066 U

0.00

+/-0.064

+/-0.064 U

13.2

+/-1.21

+/-2.10 0.00

+/-0.0578

+/-0.0578 15.4

+/-1.30

+/-2.38 97 (75%-125%)

Curium-243/244 95 (75%-125%)

Batch 622162 QC1201307626 183412001 DUP Plutonium-238 U

0.0306 U

-0.127 pCi/g 327 (0% - 100%) BXJI 04/05/07 08:18 Page 77 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD %

REC%

Ranee AnIst Date Time Rad Alpha Spec Batch 622162 Plutonium-239/240 QCI1201307628 LCS Plutonium-238 Uncert:

+/-0.0826 TPU:

+/-0.0827 U

0.00123 Uncert:

+/-0.0666 TPU:

+/-0.0666 Plutonium-239/240 QC1201307625 MB Plutonium-238 Uncert:

TPU:

13.2 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Plutonium-239/240 QC1201307627 183412001 MS Plutonium-238

+/-0.0584

+/-0.0602 U

0.0679

+/-0.120

+/-0.121 U

-0.0299

+/-0.0623

+/-0.0623 13.2

+/-1.15

+/-1.87 U

0.00

+/-0.0548

+/-0.0548 U

0.00

+/-0.0548

+/-0.0548 U

0.116

+/-0.122

+/-0.123 13.2

+/-1.22

+/-1.94 U

6.06

+/-9.04

+/-9.06 130

+/-12.9

+/-19.3 U

8.01

+/-8.10

+/-8.15 pCi/g 193 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (0%- 100%)

(75%-125%)

100 (75%-125%)

04/05/07 08:18 04/05/07 08:18 Plutonium-239/240 U

0.0306 Uncert:

+/-0.0826 TPU:

+/-0.0827 13.5 U

0.00123 Uncert:

+/-0.0666 TPU:

+/-0.0666 U

0.245 Uncert:

+/-8.37 TPU:

+/-8.37 (75%-125%)

04/05/07 08:18 98 (75%-125%)

Batch 622164 QC1201307630 183412001 DUP Plutonium-241 QC1201307632 LCS Plutonium-241 QC1201307629 MB Plutonium-241 QC1201307631 183412001 MS Plutonium-241 Rad Gamma Spec Batch 622283 QC1201307875 183412001 DUP Actinium-228 pCi/g 0

(0% - 100%) BXJI 139 Uncert:

TPU:

Uncert:

TPU:

139 U

Uncert:

TPU:

pCi/g pCi/g pCi/g 94 (75%-125%)

04/06/07 10:26 04/06/07 10:58 04/06/07 10:09 04/06/07 10:42 0.245

+/-8.37

+/-8.37 122

+/-13.3

+/-18.9 87 (75%-125%)

0.564

+/-0.160 Uncert:

0.465

+/-0.134

+/-0.134 pCi/g 19 (0% - 100%) MJHI 04/05/0709:16 Page 78 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 3 of 9 Parmname Rad Gamma Spec Batch 622283 NOM Samole Oual OC Units RPD %

REC%

Ranee Anist Date Time Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.160 u

0.0306 Uncert:

+/-0.112 TPU:

+/-0.112 u

0.259 Uncert:

+/-0.246 TPU:

+/-0.246 0.374 Uncert:

+/-0.0771 TPU:

+/-0.0771 u

0.00426 Uncert:

+/-0.021 TPU:

+/-0.021 u

0.0109 Uncert:

+/-0.0293 TPU:

+/-0.0293 U

0.00563 Uncert:

+/-0.0195 TPU:

+/-0.0195 u

0.030 Uncert:

+/-0.0674 TPU:

+/-0.0674 U

-0.00565 Uncert:

+/-0.0602 TPU:

+/-0.0602 U

-0.0141 Uncert:

+/-0.0565 TPU:

+/-0.0565 0.431 Uncert:

+/-0.0585 TPU:

+/-0.0585 0.487 Uncert:

+/-0.0724 TPU:

+/-0.0724 U

0.00555 Uncert:

+/-0.0193 TPU:

+/-0.0193 U

0.00315 Uncert:

+/-0.0185 TPU:

+/-0.0185 9.46 Uncert:

+/-0.980 TPU:

+/-0.980 0.374 Uncert:

+/-0.0771 TPU:

+/-0.0771 U

0.00418 Uncert:

+/-0.0175 U

0.0408

+/-0.0859

+/-0.0859 UI 0.00

+/-0.175

+/-0.175 0.391

+/-0.0732

+/-0.0732 U

0.0153

+/-0.020

+/-0.020 U

0.00952

+/-0.0207

+/-0.0207 U

0.0194

+/-0.0179

+/-0.0179 U

0.0188

+/-0.0616

+/-0.0616 U

-0.0548

+/-0.0748

+/-0.0748 U

-0.0151

+/-0.0508

+/-0.0508 0.380

+/-0.0707

+/-0.0707 0.456

+/-0.0821

+/-0.0821 U

-0.00315

+/-0.0176

+/-0.0176 U

0.00967

+/-0.0193

+/-0.0193 9.25

+/-0.965

+/-0.965 0.391

+/-0.0732

+/-0.0732 U

-0.0106

+/-0.0158 pCi/g 29 pCi/g 16 pCi/g 5

pCi/g 113 pCi/g 14 pCi/g 110 pCi/g 46 pCi/g 163 pCi/g 7

pCi/g 13 pCi/g 7

pCi/g 727 pCi/g 102 pCi/g 2

pCi/g 5

pCi/g 461 (0% - 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0%- 20%)

(0%- 100%)

(0%- 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Page 79 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 4 of 9 Parnmame NOM SamDle Oual OC Units RPD%

REC%

Ranie Anist Date Time Rad Gamma Spec Batch 622283 Thallium-208 QC1201307876 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-1 54 Europium-155 TPU:

+/-0.0175 0.126 Uncert:

+/-0.0346 TPU:

+/-0.0346 LCS Uncert:

TPU:

16,0 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

6.20 Uncert:

TPU:

9.31 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0158 0.144

+/-0.0413

+/-0.0413 0.770

+/-0.466

+/-0.466 13.7

+/-1.67

+/-1.67 U

0.785

+/-0.882

+/-0.882 0.469

+/-0.211

+/-0.211 U

0.0312

+/-0.0762

+/-0.0762 5.98

+1-0.559

+/-0.559 9.67

+/-0.609

+/-0.609 U

0.00251

+/-0.194

+/-0.194 U

0.0014

+/-0.176

+/-0.176 U

0.0612

+/-0.229

+/-0.229 0.951

+/-0.171

+/-0.171 0.813

+/-0.225

+/-0.225 U

-0.0375

+/-0.0684

+/-0.0684 U

-0.0137

+/-0.0655

+/-0.0655 U

0.902 pCi/g 14 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 04/05/07 09:17 (0% - 100%)

86 (75%-125%)

97 (75%-125%)

104 (75%-125%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Page 80 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 5 of 9 Parmname NOM Samnle Oual QC Units RPD %

REC%

Range Anlst Date Time Parn ame NO Rad Gamma Spec Batch 622283 Radium=226 Silver-108m Thallium-208 QCI1201307874 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 MB Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.822

+/-0.822 0.469

+/-0.211

+/-0.211 U

-0.0684

+/-0.0626

+/-0.0626 0.207

+/-0.0907

+/-0.0907 U

-0.00035

+/-0.0441

+/-0.0441 U

-0.0109

+/-0.0744

+/-0.0744 U

0.130

+/-0.108

+/-0.108 U

0.0149

+/-0.0317

+/-0.0317 U

0.0138

+/-0.0136

+/-0.0136 U

0.000391

+/-0.0136

+/-0.0136 U

-0.0115

+/-0.0154

+/-0.0154 U

-0.0154

+/-0.0373

+/-0.0373 U

-0.0253

+/-0.0371

+/-0.0371 U

-0.0127

+/-0.0396

+/-0.0396 U

0.0191

+/-0.0378

+/-0.0378 U

0.0057

+/-0.0301

+/-0.0301 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

04/05/07 09:15 Lead-212 Lead-214 Page 81 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 6 of 9 Parmname NOM Sample Oual OC Units RPD %

REC %

Ranee Anist Date Time Rad Gamma Spec Batch 622283 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.00593

+/-0.0134

+/-0.0134 U

-0.00144

+/-0.0132

+/-0.0132 U

0.154

+/-0.182

+/-0.182 U

0.0149

+/-0.0317

+/-0.0317 U

-0.0148

+/-0.0128

+/-0.0128 U

-0.00579

+/-0.0171

+/-0.0171 pCilg pCilg pCilg pCilg pCilg pCilg 622197 QC1201307713 183412001 DUP Strontium-90 QC1201307715 LCS Strontium-90 U

-0.00422 Uncert:

+/-0.0224 TPU:

+/-0.0224 U

0.0111

+/-0.018

+/-0.0181 1.57

+/-0.0987

+/-0.110 pCi/g 0

(0% - 100%) KSD1 QC1201307712 MB Strontium-90 1.40 Uncert:

TPU:

Uncert:

TPU:

U

-0.00522

+/-0.0136

+/-0.0136 pCi/g pCi/g pCi/g 112 (75%-125%)

111 (75%-125%)

04/06/07 10:38 04/06/07 10:38 04/06/07 10:38 04/06/07 10:38 QC1201307714 183412001 MS Strontium-90 Rad Liquid Scintillation Batch 622203 QC1201307730 183412001 DUP Iron-55 4.36 U

Uncert:

TPU:

-0.00422

+/-0.0224

+/-0.0224 4.84

+/-0.297

+/-0.331 U

-30.3 Uncert:

+/-24.0 TPU:

+/-24.0 U

13.8

+/-29.7

+/-29.7 pCi/g 0

(0% - 100%) MXPI QC1201307732 LCS Iron-55 QC1201307729 MB Iron-55 1150 Uncert:

TPU:

1070

+/-59.8

+/-95.4 pCi/g 93 (75%-125%)

04/06/07 09:01 04/06/07 09:35 04/06/07 08:45 U

4.58 pCi/g Page 82 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 7 of 9 REC %

Range Anlst Parmname NOM Samule Oual OC Units RPD%

Date Time Rad Liquid Scintillation Batch 622203 Uncert:

TPU:

QC1201307731 183412001 MS Iron-55

+/-30.7

+/-30.7 1110

+/-63.3

+/-100 1230 U

Uncert:

TPU:

-30.3

+/-24.0

+/-24.0 pCi/g 91 (75%-125%)

04/06/07 09:18 Batch 622207 QC1201307740 183412001 DUP Nickel-63 QC1201307742 LCS Nickel-63 QC1201307739 MB Nickel-63 QC1201307741 183412001 MS Nickel-63 1.97 Uncert:

+/-6.68 TPU:

+/-6.68 U

4.10

+/-6.84

+/-6.84 pCi/g 0

(0% - 100%) VIXPI 548 Uncert:

TPU:

Uncert:

TPU:

554 U

Uncert:

TPU:

641

+/-18.9

+/-29.5 U

2.68

+/-6.53

+/-6.53 pCi/g pCi/g pCi/g 117 (75%-125%)

04/06/07 15:06 04/06/07 15:59 04/06/07 14:34 04/06/07 15:38 1.97

+/-6.68

+/-6.68 Batch 622208 QC1201307745 183412001 DUP Technetium-99 QC1201307747 LCS Technetium-99 QC1201307744 MB Technetium-99 QC1201307746 183412001 MS Technetium-99 U

0.00684 Uncert:

+/-0.186 TPU:

+/-0.186 U

538

+/-21.9

+/-29.1

-0.0366

+/-0.202

+/-0.202 17.5

+/-0.657

+/-0.782 97 (75%-125%)

pCi/g 292 (0% - 100%) \\'IXPI 19.3 Uncert:

TPU:

Uncert:

TPU:

U

-0.0126

+/-0.171

+/-0.171 pCi/g pCi/g pCi/g 91 (75%-125%)

04/08/07 23:39 04/09/07 00:14 04/08/07 23:21 04/08/07 23:56 Batch 622513 20.1 u

0.00684 Uncert:

+/-0.186 TPU:

+/-0.186 u

0.324 Uncert:

+/-1.17 TPU:

+/-1.17 QC1201308339 183412001 DUP Tritium U

18.3

+/-0.748

+/-0.870

-0.723

+/-1.01

+/-1.01 10.8

+/-2.63

+/-2.63 91 (75%-125%)

pCi/g 0

(0% - 100%) kXD2 04/04/07 20:39 04/04/07 21:19 QC1201308341 LCS Tritium 11.1 Uncert:

TPU:

pCi/g 97 (75%-125%)

Page 83 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 8 of 9 OC Units RPD%

REC%

Ranee AnIst Parmname Rad Liquid Scintillation Batch 622513 QC1201308338 MB Tritium NOM Sample Oual Date Time Uncert:

TPU:

U

-0.195

+/-1.04

+/-1.04 pCilg pCilg 04/04/07 20:17 04/04/07 21:02 QC1201308340 183412001 MS Tritium Batch 622514 QC1201308343 183412001 DUP Carbon-14 QC 1201308345 LCS Carbon-14 11.1 Uncert:

TPU:

U 0.324

+/-1.17

+/-1.17 U

-0.0288 Uncert:

+/-0.0997 TPU:

+/-0.0997 U

9.95

+/-2.51

+/-2.51

-0.124

+/-0.0977

+/-0.0977 6.47

+/-0.189

+/-0.214 89 (75%-125%)

pCi/g 0

(0% - 100%) 'kXD2 04/09/07 17:16 QC1201308342 MB Carbon-14 6.78 Uncert:

TPU:

Uncert:

TPU:

U

-0.00443

+/-0.0957

+/-0.0957 pCi/g pCi/g pCi/g 95 (75%-125%)

04/07/07 03:56 04/07/07 00:48 04/07/07 02:53 QC]201308344 183412001 MS Carbon-14 7.01 U

-0.0288 Uncert:

+/-0.0997 TPU:

+/-0.0997 6.88

+/-0.194

+/-0.222 98 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound Page 84 of 85

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183412 Page 9 of 9 Parnmame NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time Y

A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery-limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 85 of 85

Table of Contents General Narrative..................................................................

1 Chain of Custody and Supporting Documentation...........

5 Data Review Qualifier Definitions.......................................

9 Radiological Analysis...........................................................

11 Sample Data Summary......................................................

15 Q uality C ontrol D ata..........................................................

19

General Narrative.

I

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 183554 SDG: MSR#07-00139 April 09,2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The sample arrived at GEL Laboratories LLC, Charleston, South Carolina on April 04, 2007 for analysis.

Shipping container temperature was checked, documented, and within specifications. The sample was delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following sample:

Laboratory Sample Identification Description 183554001 9302-0000-019-1 Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request One soil sample was analyzed for FSSGAM.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Project Manager GEL Laboratories LLc POBox30712 ChaWeston,SC29417 2040 Savage Road Charleston, SC29407 P843.556.8171 F843.765.1178 2

www.gol.com

Cheryl Jones Project Manager GEL Laboratories LLC P0 Box 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.556.8171 F 843.766.1178 3

www.gel.com

List of current GEL Certifications as of 09 April 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy "NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4

Chain of Custody and Supporting Documentation 5

Connecticut Yankee Atomic Power Company Chain of Custody FormN 362 Injun Hollow Road. East Hamptn. CT 064242007-00' I

860-267-2556 Project Name: Haddam Neck Deconminissioning

Analyses Requested La bUse Oni

Contact Name& Phone:,

Comni111en:.

Jack McCarthy 860-267-3924 Media SipiIe Contauiner, Cde Trn.

' Si~ze Analytical Lab:(Name, City,. State):

Code r-irUP Genera Engineering Laboratories C.de.

2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jone (8943-556-817 1)

Priority: El 30 D. E] 15 D..

7 D.

Other:

.a, Sample Designation Date Time

.Prese6iaion I ih impk 11) a)

9302-0000-019-1 4/3/07 0952 TS G

BP X

i F

NOTES.: P)0.

002332 MSR #:'-

P Q.

E...

.dwast&

QA JD Non, 'QA S,"

I Shp pe. Via:

Interndl Cotairi SFed x

Ten<p.*:..

Deg. C

  • +

IZ] UPS fHand; Cusodv Sealed?,

1) Retinquis1t.-

Dat /Time

2) Reeiv y

DateTime Custody Seal hitnacl?

3) Relinquished BY Date/Time
4) Received By Dare/Time Y

N Bill of Ladiig #

5) Relinquished By Data/Time
6) Received By Date/Time 6)Rev b itt.e:

Connecicut Yankee Statement of Work for Analytical Lab Services Figure 1. Sample Che:in List Date/Ti Xeeccived w/,

SDOAa*

~o1~V Shipp* gcbtainerlD) 7&146'

  • ~'

Chain qfCustody #

A o D

CustodySealsorishippingcontainerintact?:.,

Yes 1]0o [ ]

2.

Custody Seals dated and signed?

Yes (3 No [1

3.

Chain-ofICustoiy rcwnlp.esent?

Yes

-4.

Cooler temperatureý

-tr O

_VermiCulitelpackingmaterialsis:

Wet.

Dry 6.'

Numberofsamples in shipping container F r

7.

Sample holding times.eceeded?

Yes [

No 8.--hazard labels seals appropriate sample labels I

9. Samples aret In good Condition

.jek g

.... r.e

-have air bubbles.

10.

Were anyomafles identifiedin s r

Yes [

No"

11.

escr of anomalies (include:

a

enmber):

~a n ~ l e C at o d a zt

~ b o r s o z y :D a te

2 Telephoned to
,B

++

+7

SAMPLE RECEI

& R EVIEWFORM PMuse only

.c.it.

SD/ARCO.W.rkOrder..

PDate Rkeceived:

PM(A)Rkevewe enodwsriOnfn~

t emare resolved pio to signing):

Sample Receipt Criteria V

Comments/Qualiflers (Required for Non-Conforminlg item)

Shipping containers received Circle 'Applicable: seals broken damagedvcoatair lek4ikt cotainer Other (describe) 1fintactand seaied?

Samples requCiringcold Circle Coolat i ke bUas blue ice ftli ce amne other describe) 2 preservation within:(4 +1-2C)?

Record reservation method.-

Chain of Icustody documents, ifilu~dedwith shipment?

0 S ele wontahiershintact and:

r. I
  • Applicable: seals broken damaged comainer leakiqngcorttainer otle(describ*)

t S amplecnanesitc sealed?

Samples :requiring chemicalr S.

coruinens anffetd:and observed pH.:

. Preservationwat poer pl?..

at properm pH?

l)'s acotiners, affected:

6:VOA Vialsfree of. headspace' 6(defined as <= 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding,d's and tests affected:

,Sample IDs on COC match ID's Sample ID's and conaine-affect on, bottles?

Date & time on COC match date Sample, ID's affected:

&.time.on, bottles?

Number of.containers received uipt t's aff..

match number indicated on COC?

COC form is properly signed in 2

uished/receiv ons Air Bill.,Tracking #'s, &

4 Additional Comments 4

, 'ta RSOPAD Receipt #

SusecedHaar r

  • If:> x2.area background is observed on samples identified.as 'non-Suspected...

Hazad Infornliation':....

1+J + I 9I+'+

+ ++2 SI regulalednon-radioactive".contact -the RadiationISafetyIgroup for frther 09a investigation.

I A lxaaOioga9cai uiassirication!1 I I~aimumCounts Observed*:

I I--

B PCB Regulated?

C Shipped as Lu I Hazardous Material? If yes, contact Waste Manager or ESH Manager.

Hlzard Class Shipped:

LJN#:

.n.. ia...Date:.q qiI I

Regulated as a Foreign Soil?

'r PMAI review of Hazard classification:

,7 ntal ae 4IL 7

Data Review Qualifier Definitions 9

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GEL Laboratories LLC POBox30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P843.555.8171 F843.755.1178 10 www.gel.com

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 183554 Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 183554001 1201308632 1201308633 1201308634 EML HASL 300, 4.5.2.3 Dry Soil Prep 622655 622627 Client ID 9302-0000-019-1 Method Blank (MB) 183480001(9306-0000-020-1) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 183480001 (9306-0000-020-I).

12

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and duplicate, 1201308633 (9306-0000-020-I), did not meet the relative percent difference requirement for T1-208, however they do meet the relative error ratio requirement with a value of 1.66236.

Qualifier information Qualifier Reason Analyte Sample UI U'

UI Data rejected due to high peak width.

Data rejected due to low abundance.

Data rejected due to no valid peak.

Cesium-137 Cesium-134 Potassium-40 1201308633 183554001 1201308633 1201308632 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the 13

data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

(Ui)i W'/6/J7 14

SAMPLE DATA

SUMMARY

15

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-00139 GEL Work Order: 183554 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 16

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: April 1D, 2007 Client Sample ID:

9302-0000-019-1 Project:

YANK01204 Sample ID:

183554001 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

03-APR-07 Receive Date:

04-APR-07 Collector:

Client Moisture:

5.04%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.44

+/-0.293 Americium-241 U

0.107

+/-0.120 Bismuth-212 0.713

+/-0.385 Bismuth-214 1.47

+/-0.193 Cesium-134 UI 0.00

+/-0.0533 Cesium-137 U 0.000861

+/-0.0524 Cobalt-60 U

-0.0134

+/-0.0328 Europium-152 U

0.0837

+/-0.0891 Europium-154 U

-0.0643

+/-0.111 Europium-155 U

-0.0103

+/-0.104 Lead-212 1.44

+/-0.153 Lead-214 1.39

+/-0.186 Manganese-54 U

0.00741

+/-0.0301 Niobium-94 U

0.0314

+/-0.0301 Potassium-40 22.8

+/-1.91 Radium-226 1.47

+/-0.193 Silver-108m U 0.000724

+/-0.0295 Thallium-208 0.431

+/-0.0798 0.0941 0.100 0.219 0.0554 0.036 0.029 0.026 0.080 0.0729 0.0924 0.0473 0.0571 0.0263 0.0267 0.204 0.0554 0.0256 0.0273

+/-0.293

+/-0.120

+/-0.385

+/-0.193

+/-0.0533

+/-0.0524

+/-0.0328

+/-0.0891

+/-0.111

+/-0.104

+/-0.153

+/-0.186

+/-0.0301

+/-0.0301

+/-1.91

+/-0.193

+/-0.0295

+/-0.0798 0.188 0.200 0.437 0.111 0.0719 0.058 0.0521 0.160 0.146 0.185 0.0946 0.114 0.0526 0.0534 0.407 0.111 0.0511 0.0545 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 04/06/07 0423 622655 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 04/04/07 1141 622627 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows Analyte is a surrogate compound 17

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: April 10, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9302-0000-019-I Project:

YANK01204 Sample ID:

183554001 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

18

QUALITY CONTROL DATA 19

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd ReDort Date: April 10, 2007 Page 1 of 5 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

183554 Parmname NOM Sample Oual OC Units RPD %

REC%

Ranee Anlst Date Time Rad Gamma Spec Batch 622655 QC1201308633 183480001 DUP Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 1.38 Uncert:

+/-0.356 TPU:

+/-0.356 Ul 0.00 Uncert:

+/-0.0774 TPU:

+/-0.0774 0.953 Uncert:

+/-0.572 TPU:

+/-0.572 1.61 Uncert:

+/-0.232 TPU:

+/-0.232 U

0.0508 Uncert:

+/-0.054 TPU:

+/-0.054 U

0.0595 Uncert:

+/-0.0724 TPU:

+/-0.0724 U

-0.0463 Uncert:

+/-0.0468 TPU:

+/-0.0468 U

0.0542 Uncert:

+/-0.142 TPU:

+/-0.142 U

-0.171 Uncert:

+/-0.153 TPU:

+/-0.153 U

0.0608 Uncert:

+/-0.127 TPU:

+/-0.127 1.32 Uncert:

+/-0.162 TPU:

+/-0.162 1.88 Uncert:

+/-0.246 TPU:

+/-0.246 U

0.0268 Uncert:

+/-0.0477 TPU:

+/-0.0477 U

0.0332 Uncert:

+/-0.0472 TPU:

+/-0.0472 1.44

+/-0.334

+/-0.334 U

0.081

+/-0.0682

+/-0.0682 0.989

+/-0.549

+/-0.549 1.45

+/-0.243

+/-0.243 UI 0.00

+/-0.0607

+/-0.0607 UI 0.00

+/-0.0717

+/-0.0717 U

-0.00321

+/-0.0534

+/-0.0534 U

-0.0128

+/-0.138

+/-0.138 U

-0.0914

+/-0.159

+/-0.159 U

0.137

+/-0.109

+/-0.109 1.30

+/-0.157

+/-0.157 1.58

+/-0.219

+/-0.219 U

0.0269

+/-0.051

+/-0.051 U

0.00914

+/-0.0525

+/-0.0525 pCi/g 5

pCi/g 60 pCi/g 4

pCi/g 11 pCi/g 86 pCi/g 36 pCi/g 174 pCi/g 323 pCi/g 61 pCi/g 77 pCi/g 2

pCi/g 17 pCi/g 0

pCi/g 114 (0% - 100%) MJH1 04/10/0709:39 (0%- 100%)

(0% - i00%)

(0% - 20%)

(0% - 100%)

(0%-

100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 20%)

(0% - 20%)

(0% - 100%)

(0% - 100%)

20

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183554 Page 2 of 5 Ranze Anlst Date Time Parmname NOM Sample Qual OC Units RPD%

REC%

Rad Gamma Spec Batch 622655 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201308634 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 20.9 Uncert:

+/-1.99 TPU:

+/-1.99 1.61 Uncert:

+/-0.232 TPU:

+/-0.232 U

0.033 Uncert:

+/-0.0409 TPU:

+/-0.0409 0.369 Uncert:

+/-0.109 TPU:

+/-0.109 22.2

+/-1.92

+/-1.92 1.45

+/-0.243

+/-0.243

-0.0527

+/-0.0395

+/-0.0395 0.503

+/-0.114

+/-0.114 pCi/g 6

pCi/g 11 pCi/g 872 pCi/g 31*

(0% - 20%)

(0% - 100%)

(0% - 100%)

(0%-20%)

U LCS Uncert:

TPU:

16.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

6.35 Uncert:

TPU:

9.53 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

1.36

+/-0.598

+/-0.00 13.8

+/-1.38

+/-0.00 1.93

+/-1.49

+/-0.00 0.887

+/-0.295

+/-0.00 U

0.0849

+/-0.109

+/-0.00 6.17

+/-0.595

+/-0.00 9.73

+/-0.704

+/-0.00 U

-0.0829

+/-0.279

+/-0.00 U

-0.0535

+/-0.227

+/-0.00 U

0.140

+/-0.319

+/-0.00 1.57

+/-0.264

+/-0.00 1.06

+/-0.304 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 04/06/07 13:38 84 (75%-125%)

97 (75%-125%)

102 (75%-125%)

Lead-212 Lead-214 Uncert:

21

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183554 Page 3 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 622655 TPU:

Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201308632 MB Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.00 U

0.029

+/-0.0987

+/-0.00 U

-0.0205

+/-0.112

+/-0.00 U

1.20

+/-0.931

+/-0.00 0.887

+/-0.295

+/-0.00 U

0.0565

+/-0.0899

+/-0.00 0.453

+/-0.166

+/-0.00 U

-0.00616

+/-0.0926

+/-0.0926 U

0.102

+/-0.0847

+/-0.0847 U

-0.145

+/-0.200

+/-0.200 U

-0.0179

+/-0.0539

+/-0.0539 U

0.00204

+/-0.023

+/-0.023 U

-0.0531

+/-0.0276

+/-0.0276 U

0.0204

+/-0.0209

+/-0.0209 U

0.0229

+/-0.0607

+/-0.0607 U

-0.0182

+/-0.0507

+/-0.0507 U

0.0553 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 04/06/07 07:28 (75%-125%)

22

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183554 Parmname Rad Gamma Spec Batch 622655 Page 4 of 5 Range Anist Date Time NOM Sample Qual QC Units RPD%

REC%

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0635

+/-0.0635 U

0.00638

+/-0.0627

+/-0.0627 U

0.0537

+/-0.0864

+/-0.0864 U

0.0203

+/-0.0215

+/-0.0215 U

0.00193

+/-0.0218

+/-0.0218 U1 0.00

+/-0.386

+/-0.386 U

-0.0179

+/-0.0539

+/-0.0539 U

-0.0253

+/-0.020

+/-0.020 U

0.0494

+/-0.0412

+/-0.0412 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Notes:

The Qualifiers in this report are defined as follows:

A B

C D

H J

N/A ND R

U UI Analyte is a surrogate compound Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product For General Chemistry and Organic analysis the target analyte was detected in the associated blank.

Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Analyte concentration is not detected above the detection limit Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Gamma Spectroscopy--Uncertain identification 23

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

183554 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

24

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

Revision 0

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Revision 0

Hea~lth,Physics Procedure GP'P-GGGR-R51 t1-001 Attaichment B, Rev. CY-O01 MAJOR Ft caith Physics Procedure GPP-GGGR-R5121-00t Attachment B. Rev. CY-OQI MAJOR Preliminary Data Review Form;- Samples for the Sign Test Survey Area:

Survey Unit Name:

Classification:

Survey Media:

Type of Survey:

Type of Measurement:

Number of Measurements:

Operational IXCGL:

ý93O~~

Survey Unit[~Qo ImnalSi (irounds OoMeSur meNt 15 k c ne BASIC STATISTICAL QUANTITIFRS Minimum Value:

Maximum Value:

Mean:

Median:

Standard Deviation:

Skew:

.Cs-137

-53~71*,-3'f) 1151-'!00A Co-60

-3,L031`0 5Ai31E'03

),20FE-02>

1'23ý51-00 RADIONUCLII)D CONCENTRXATION (pCi/g)

NUMBER CS-137 Co-60 Cs ldentified'~ Co Identified?

9302-0000-0001 F

, I<

tO9E-02

  • 5.63E.03*.

NO NO 93O~02-000-02F 4,31 E-02 3 5-9E 0l3I____

YES NO F,

741 A E 02J

-189E02 0

IN, NO 9302-0000-0 117

-..3.E..

-7.4E 03.

NO NO

>931020o0o-001'O5 2..2..

-1,24E-0'2 NO 7....NO.

9302-0000-006F<

1.48E-02~

7,60E03 ~>1 O~

NO S9-332-~0000-007f:

4,A96E02~

1,59E-02~

>YES N 0NO 79' 02-0000-00I8F A 6Eb 63FE02

~

~

'O>~

O 9302-0000-00%

1 70E-023 6 16E-05 "YES, :. !7 9302-0000-0 1 OF 25E-1 1., 1..E-0Y.

YES 9 1,302-P0000-01I F

_3,.19E-02 1,40E-02

~YES

'<NOA~____

9302-O0000412F

-4ý 1 2E-03 1,42E-02>~'~

NO NO 9302-0000-1-I31:

-3.62E-037 2,1 2E-02

2NO, NO 93 2 00 -0 1l4F 2,85E03' 4~64E -)32 NO

--~

1) 302Y-O Q0 -0 5 F T32E0 11 I-6027 No

~

NO 72 Date:

Perlbrmed By:

Independent Review:

Date: 4

[07

Hfalth Physics Procfdurf 24265.-OOO-GI'PýCiCiCiR-R5123-000-Rev.CY-OOC Hfalth Physics Procfdurf 24265+000~GPP~G(iGR-R5 I 23-000~Rev.CY4)OC Preliminary bataReview Form - JudgementalS. artpl es SurveyUnit:W Survey Unit Name:

Classification:

Survey Media:

Type oe Survey:

Type oe. Measurement:

Numberof Measurements:

Operational DCGL:

9302- 0000 Northwest Protected Area Grounds

  • oil I1inal ttI (re Giross3 asre nt BASIC'STATISTICAL QUANTITIES Cs-137 Co-GO Sr-90 Minimum Value:

f I

I Maximum Value:

2,)V05-2~

3B0~OO~

Mean:

95,2 -043

ý 13,[94W03 C) I~00 Median:

I0E0

<OE0

.010 Standard 'Deviation:

1, I 2E 02 i o2.I6E,2 0.00E 4 00 RADIONUCLIDE CONCENTRATION (pCi/g)

Co-60 Co iD'ed Sr-90 NUMBER Cs-,137

.Cs ID'ed?

Sr ID'ed

> DCGL Pertbrmcd By:

Date: _

Independent RciW vv'VaTVý,o

[Date:

-4/19I0i

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

Revision 0

I lealth Physics Procedure

(;(GR-R5 123-Rcev.('Y-001 Attachment C Quantile Plot For Cesium - 137 Survc\\

w fnit:

9302-0000

.Sur\\C. Iflit Name: Northwest Protected Area Grounds Mean:

2.7-1>-02 p('i6-2.50E-01

"" 2.OOE-01 0

.1.50E-01 5.00E-02 0o 0.OOE+00 20 40 1 )0 60 80

-5.00E-02 Percentage Cs-137

-5.37E-03

-4.12E-03

-3.62E-03

-3.24E-03

-1.61E-03 2.27E-03 2.85E-03 1.09E-02 1.48E-02 1.70E-02 3.19E-02 4.11E-02 4.31 E-02 4.96E-02 2.15E-01 Rank 1

2 3

4 5

6

.7 8

9 10 11 12 13 14 15 Percentage 3%

10%

17 %

23 %

30 %

37 %

43 %

50 %

57 %

63 %

70 %

77 %

83 %

90 %

97 %

Prepared By. 1//

Reviewed8.o\\c 4*

Date:

6

-7 Date.

(

/

c'7

I lealth PhN'sics ProcedUre GGGR-R51'-)3-Rcv.(.'Y-001 Attachment C Quantie ["lot For Cobal~t - 60)

Survey Unmit:

Survex U n it Namne:

Mean:

9302-0000 Northw~est P~rotected Area (irounds K2bIK-03 )(,Ilg

.2 4-0 C-1.20E-01 1OOE-01 8.OOE-02 6.OOE-02 4 OOE-02 2.OOE-02 0.OOE+00

-2OOE-02

.i 2_0 40 60 80 100

-4.OOE-02 I*

-6OOE-02 Percentage Co-60

-3.63E-02

-1.89E-02

-1.24E-02

-7. 14E-03

-4.64E-03 6.46E-05 3.59E-03 5.63E-03 1.11E-02 1.40E-02 1.42E-02 1.59E-02 2.12E-02 2.12E-02 1.1 OE-01 Rank 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 Percentage 3%

10%

17 %

23 %

30%

37 %

43 %

50 %

57 %

63 %

70 %

77 %

83 %

90 %

97 %

I PrepaveeB-Reviewed O*

  • o 4TK6 w Date V, -,/')-_

Date

'+] 9 0x7

I lealth Physics ProcedUre I Icith ~hvics roceure(IGG~R-R5 I 23-Rcv.('Y-)(,) I Attachment C~

Frequency Plot For Cesium-137 SLurvey I 'nit:

9302-0000 Sur'y ![Init Name: Northwest Protected Area Grounds Mean:

0,027 p('i/g (1) 1L.

6 5

4 3

2 1

0 0.000 0.009 0.017 0.034 0.068 0.125 0.250 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0,000 5

33%

0.009 2

13%

0.017 3

20%

0.034 1

7%

0068 3

20%

0.125 0

0%

0.250 1

7%

Total 15 100%

Prepared Byv:

Reviewed By.:

I Date:

..-t/ ;- 6 9 I)atc:

LI

,i )o-7

I fealth 111wsics llroCC(ILire I Icithl~hsic I~oceureGiGR-R5 I 23-Rev.CY-00I Attachment ("

Frequency Plot For Cobalt-60 Stirvey U nit:

9302-0000 Survy I fnit Name: Northwest Protected Area Grounds Mean:

0.008 pCi/g U.

7 6

5 4

3 2

1 0

-0.010 0.010 0.030 0.050 0.070 0.090 0.110 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency

-0.010 3

20%

0,010 5

33%

0.030 6

40%

0.050 0

0%

0.070 0

0%

0.090 0

0%

0110 1

7%

Total 15 100%

Prepared By:

Reviewed By:

Date:

7

ý- ()40 D)ate:

7 -/7 o-7

- -- T Jýý

-]ý j 01

-Y -4Jr(A V-

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Revision 0

Health Physlc* Pmcedme I lea~h Phsics.Proccw'e PP-(;C(;[UR-5 12 i~o t

~ht A RevW CY-001l

'MA I('u Sign Test Cakulation Sheet for Multiple Radionuch~i~k Surwy. Unit Nonbr:

9302-0000 Survey Unit Nan: Niwfha

.Prted rv (ison Radionudides:

( AC 13, -

Co-6 Sr-90 Operational 1)CGL (Pci/g):

4. 75 saut-; C3-1" 7

'1 69 -02 4.1,6 1 -02 4417OF-02 22~

Resuts Co-60 Weighted Sum (W) 563 11-031 6-1,8130 I7 I41-F 2.46 ~03~

~5j713~Q3*

-8 2513-03

-3.1213-03, 4.9413-03

~ f2F:~2 I.7413-02 4.6213-0k 3.60 >03 9.33 '-02 l..81i-02~

5.3313-03 8.501>02K

-1.43 '-03" 4.85 '-0 9.9813-48 1AtI L.411+00 I ")OF00 IOO' 00 9 ý881%01' 991,02E.0

.9.87F3-0 9.95 1;.0 1 I.0013+00 9.9513-01 Sig~n A'

A I

.1 1.

1..,.

1

.1 Number of Positive DifThrettecs (54'):

15 Critical Value:

13 Sirv Pcire fly:

01 j'

3 5 K

[m Joludt I 'vio'a...._

'cy Utlit:

vet Acpýe Criterion vit:

4 fc

......... i_

J

'I

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Revision 0

Connecticut Yankee I)ecommissioning Project I Hcalth Physics Procedure

'4 '6)5 -(fl-( IPR-(,( i( R-1ý5124-t)Ut) Attachmnent A\\

Split Sample Assessment Form Survey 9302 Survey 0000 Survey Unit Northwest Protected Area Grounds Areati:

Unit #:

Name:

Sample Plan or WPIR#:

NA SMI. t:

0 Sample

Description:

Comparison of split samples collected from sample measurement location P, 13 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9302-0000-01 3F. the comparison sample was 9302-0000-013FS.

STANI)ARRD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137

-3.62E-03 1.38E-02 0

NONE -

1.22E-02 1.02E-02

-3.37 NA Co-60 2.12E-02 1.33E-02 2

NONE-

-1.58E-04 1.12E-02

-0.01 NA K-40 1.86E+01 5.75E-01 32 0.75-1.33 1.80E+01 4.77E-01 0.97 Y

Comments/Corrective Actions:

With regard to the Cs-137 & Co TFable is provided to show acceptance criteria used to 60 results, guidance for agreement ranges, obtained from assess split samples.

USNRC Inspection Procedure 84750, does not address resolution ratios less than 4. therefore, a determination of Resolution Agreement Range acceptability for such rations cannot be made. I lowever, K-40 4

7 0.50 2.00 was found to be present at an acceptable level of agreement.

8 15 0.60 1.66 Therefore, no further action is warranted.

16 50 075 133 51 200 0.80 1.25 1200 0.85 1.18 Performed Date:

Reviewed By:

Date:

WPIR - Work Plan and Inspection Record SMIL-Sample Measurement I.ocation designation

_f Page I of I

Connecticut Yankee )ccommnissioning Project I lealth Physics Procedure 24265-U(JO-( i 11<-t( Kit R-5 1<SI24-000t Attachment A Split Sample Assessment Form Survey 9302 Survey 0000 Survey Unit Northwest Protected Area Grounds Areat.:

IUnit 0:

Name:

Sample Plan or WPIR4:

NA SML i:

0 Sample

Description:

Comparison of split samples collected from sample measurement location 415 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9306-0000-015tF, the comparison sample was 9306-0000-015[FS.

STANDARI)

COMPARISON Radionuclid Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N) e Value Frror Range Value Frror Ratio Cs-137

-3.24E-03 1.44E-02 0

NONE -

-3.76E-03 1.68E-02 1.16 NA Co-60

1. II E-02 1.55E-02 I

NONE -

-2.41E-04 1.92E-02

-0.02 N A K-40 1.64E+01 7.75E-01 21 0.75-1.33 1.55E+01 8.OOE-01 0.95 Y

Comments/Corrective Actions: With regard to the Cs-137 & Co-60 Table is provided to show acceptance criteria used to results, guidance for agreement ranges, obtained from USNRC assess split samples.

Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations Resolution Agreement Range cannot be made. I lowever. K-40 was found to be present at an 4

7 0.50 2100 acceptable level of agreement. Therefore. no further action is 8

15 0.60 1.66 warranted.

16 50 0(75 1.33 51 200 0.80 1.25

<>200 0.85 1.18 Performed By:

Date:

Reviewed Fly:

Date:

7-A-*

4,10 WPIR - Work Plan and lnspe tion Record SMI, - Sample Measurement Location designation

.j Page I ol I

NORTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9302-0000 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

Revision 0

DQA Surface Soil Report Assessment Summary Site&

Planner(s):

Survey Unit Name Report Number:

Survey Unit Samples Reference Area Samples:

Test Performed:

Judgmental Samples Assessment

Conclusion:

CY-03 RWM 9302-0000 1

15 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve

=

3-1.

1 09 08 07 06 05 04 03 02 01 0

00 02 04 0.6 0.8 10 Unity Rule Sum-of-Ratios, including backgrounm Prospective Power U

1-beta Actual Power LBGR Estimated Power DCGL Retrospective Power 12 COMPASS vl.0.0.P 4M172007 Page 1