Final Status Survey Final Report Phase VI - Appendix A4, Survey Unit Released Record 9506-0000, North Site Grounds, Book 5 of 18
ML070740598
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 02/13/2007
From:
Connecticut Yankee Atomic Power Co
To:
Office of Nuclear Material Safety and Safeguards
References
Download: ML070740598 (178)


Text

CB:ook 5 oýf ý18 V

Final Status Survey Final Report Phase VI Appendix A4 Survey Unit Release Record 9506-0000, North Site Grounds (Non-Protected Area)

February 2007

CYAPCO FINAL STATUS SURVEY RELEASE RECORD NORTH SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9506-0000 Prepared By:

Reviewed By:

Approved By:

Date:

.z//q

  • v FSS Itngineer 1), -

FSS Engliieei DPate:

/

07

,*..ff Date:

/*

I Technical Support Manager Revision 0

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLASSIFICATION BASIS...............................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..........................................

5

4.

SU RV EY D ESIGN.............................................................................

8

5.

SURVEY IMPLEMENTATION.......................................................

11

6.

SU RV EY RESU LTS........................................................................

12

7.

QUALITY CONTROL....................................................................

15

8.

INVESTIGATIONS AND RESULTS.............................................

15

9.

REMEDIATION AND RESULTS...................................................

15

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......

16

11. DATA QUALITY ASSESSMENT (DQA).......................................

16

12. A N O M A L IE S....................................................................................

17

13. C O N C LU SIO N..................................................................................

17

14. A TTA CH M EN TS..............................................................................

18 14.1 - Figures (7 pages including cover) 14.2 Attachment 2 - Scan Results (4 pages including cover) 14.3 Attachment 3 - Laboratory Data (135 pages including cover) 14.4 Attachment 4 - DQA Results (13 pages including covers)

TOTAL 177 Revision 0

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9506-0000, North Site Grounds (Non-Protected Area)/

Emergency Operations Facility (EOF), is designated as Final Status Survey (FSS) Class 3 and consists of approximately eleven thousand two hundred forty four square meters 11,244 m2 (2.77 acres) of open land area located approximately 0.08 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP) (see Attachment 1, Figure 1). The North Site Grounds survey unit is bounded as follows: on the west by the Survey Unit 9512-0000; Survey Unit 9504-0000 is to the east; Survey Unit 9514-0000 is to the south and the property boundary bounds this unit to the north (called north as oriented with the north to south flow of the Connecticut River). The Storm Water Retention Pond, Survey Unit 9508-0000, is located in the interior of the survey area.

The survey unit is comprised of predominately flat open land area.

The survey unit slopes from north to south, in the direction of the pond.

The area around the pond is densely populated with trees and small brush.

The EOF building is located within the survey unit. Several sea land storage containers are located in the northern portion of the survey unit. These sea land storage containers are used for storage and preparation of FSS samples and miscellaneous materials.

The EOF structure will remain on-site and several underground structures will be abandoned in place (i.e. a septic system; two (2) electric/telephone duct banks; a well water storage tank; and several storm water culverts associated with the bypass road). Radiological surveys will be performed to confirm that the components or structures will meet all applicable unrestricted release criteria (reference CY memo CY 093 and License Termination Plan (LTP) Section 2.3.3.1.2.7).

The reference coordinates associated with this survey area are E005 through E011 by S039 through S052 (refer to LTP Section 5.4.4, Figure 5-2). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9506-0000 as Class 3 in May 2006.

Revision 0 3

Revision 0 3

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD The "Classification Basis Summary" conducted for this survey unit consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historical Site Assessment (HSA) Supplement,"

c) Historic and current survey records review, d) Visual inspections and a "walk-down."

A review of the 10CFR50.75 (g) (1) database report identified one (1) significant radiological event that may have impacted this survey area.

In March 1980, Plant Incident Report (PIR) 80-37 reported the discovery of several areas of elevated activity throughout the site. The investigation into the incident concluded that the elevated activity was most likely ejected from the Primary Vent Stack as a result of operational events in 1979. In all cases, the areas of elevated activity were removed upon discovery.

A review of the historical documents included the "Results of Scoping Survey", (performed during late 1997) and the "Historical Site Assessment" which provided no additional information.

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries " provided no additional information pertinent to the classification.

Characterization was performed in June 2006 to obtain data of sufficient quality for Final Status Survey (FSS) planning purposes. This sampling was performed under Survey Sampling Work Plan (SSWP) 06-06-006. Nine (9) soil samples were evaluated overall. All of the samples were analyzed on-site using gamma spectroscopy. A Hard-to-Detect (HTD) analysis was conducted on one (1) of the nine (9) samples. Statistical quantities (mean, median and standard deviation) from the 2006 characterization survey are provided in Table 1).

Table 1 -

Basic Statistical Quantities for Cs-137 from the Characterization Survey Parameter Cs-137 (pCi/g)

Minimum Value:

1.07E-02 Maximum Value:

1.32E-01 Mean:

5.94E-02 Median:

4.45E-02 Standard Deviation:

3.95E-02 Revision 0 4

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

The final designation was Class 3 based on historical information and the characterization survey data which provided sufficient data to conclude that FSS sample results will be a fraction of the Operational DCGL of nineteen (19) mrem/yr.

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process is provided herein.

The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is defined as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS. Probabilistic sampling is a preferred method to select a sample so that each item in the population being studied has a known likelihood of being included in the sample.

Probabilistic sampling may include simple random sampling where every sample has the same chance of being included, or systematic random sampling where samples are arranged in some order and a random starting point is selected.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9506-0000 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of Derived Concentration Guideline Levels (DCGLs).

The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.

Revision 0 5

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

HTotal-Hsoil (sediment) + HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr Total Effective Dose Equivalent (TEDE) from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above (reference CY memo ISC 06-024).

This survey unit is not affected by existing groundwater radioactive contamination (reference CY memo ISC 06-024).

Therefore the dose contribution from existing groundwater is zero (0) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no contaminated concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024).

Therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

Equation 2.

19 mrem/yrTotal= 19 mrem/yrsoj1+0 mrem/yrExisting GW+O mrern/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in nineteen (19) mrem/yr TEDE is designated as the Operational DCGL(s), and has been established for the radionuclides of concern as provided in Table 2.

Revision 0 6

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Table 2 -

Radionuclide Specific Base Case Soil DCGLs, Operational DCGLs and Required Minimum Detectable Concentrations Base Case Soil Operational Required MDC Radionuclide )

DCGL DCGL (pCi/g) (2)

(pCi/g) (3)

(pCi/g) (4)

H-3 4.12E+02 3.13E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-01 Mn-54 1.74E+01 1.32E+01 6.96E-0 1 Fe-55 2.74E+04 2.08E+04 1.1 OE+03 Co-60 3.81E+00 2.90E+00 1.52E-01 Ni-63 7.23E+02 5.49E+02 2.89E+01 Sr-90 1.55E+00 1.18E+00 6.20E-02 Nb-94 7.12E+00 5.41E+00 2.85E-01 Tc-99 1.26E+01 9.58E+00 5.04E-01 Ag-108m 7.14E+00 5.43E+00 2.86E-0 1 Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-01 Eu-152 1.01E+01 7.68E+00 4.04E-01 Eu-154 9.29E+00 7.06E+00 3.72E-01 Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+01 2.25E+01 1.18E+00 Pu-239/240 2.67E+01 2.03E+01 1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 (5) 2.58E+01 1.96E+01 1.03E+00 Cm-243/244 2.90E+01 2.20E+01 1.16E+00 (1)

(2)

(3)

(4)

(5)

Bold indicates those radionuclides considered to be Hard to Detect (HTD)

The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE The required MDC is equivalent to one (1) mrem/yr TEDE Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Revision 0 7

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was performed in June of 2006 as discussed in Section 2. Cs-137 was found to be the only radionuclide of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 are provided in Table 1.

Laboratory DQOs and analysis results were to be reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans". The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The dose for soil, used in this survey area to demonstrate compliance with the LTP criteria, is nineteen (19) mrem/yr TEDE, as discussed in Section 3 of this Release Record.

The DQO process determined that Cs-137 was the radionuclide of concern in Survey Unit 9506-0000 (refer to Section 3). Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 3 and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. In addition, this approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans" to 5.93 pCi/g Cs-137 to maintain the relative shift (A/a) in the range of 1 and 3. The resulting relative shift was 2. A Prospective Power Curve was generated using COMPASS, a software package developed under the Revision 0 8

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E).

The result of the COMPASS computer run showed adequate power for the survey design. This indicates that the survey area has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results.

Survey design specified fifteen (15) soil samples for non-parametric statistical testing.

The locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A random location was selected for sample design, which is appropriate for a Class 3 area.

Sample locations were identified using AutoCAD-LT, commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

The sample location designations of Table 3 are not sequential due to changes made at the south boundary of Survey Unit 9506-0000.

The locations of three (3) of the fifteen (15) samples to be used for non-parametric-statistical testing were absorbed into Survey Unit 9514-0000.

Table 3 -

Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9506-0000-OO1F 237323.22 667804.71 9506-0000-002F 237275.35 667476.34 9506-0000-005F 237280.19 667447.67 9506-0000-006F 237379.09 667478.38 9506-0000-007F 237381.92 667579.77 9506-0000-008F 237443.22 667343.70 9506-0000-009F 237467.97 667347.74 9506-0000-01OF 237516.94 667278.90 9506-0000-011F 237647.15 667369.52 9506-0000-012F 237613.06 667372.78 9506-0000-013F 237325.85 667829.02 Revision 0 9

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Table 3 - (continued)

Designation Northing Easting 9506-0000-014F 237328.22 667446.36 9506-0000-018F 237336.62 667793.84 9506-0000-019F 237289.89 667471.53 9506-0000-020F 237161.20 667500.97 Sample locations 9506-0000-003F, 9506-0000-004F, and 9506-0000-015F were absorbed into Survey Unit 9514-0000. Three (3) new sample locations, 9506-0000-018F, 9506-0000-019F and 9506-0000-020F were determined using VSP in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. "

Judgmental or biased sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.

Sample numbers 9506-0000-016F and 9506-0000-017F identify the biased sample locations that were selected for this survey unit.

Although Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans " only specified that 5% of the samples be selected for HTD analysis, two (2) soil samples or 13% of the samples collected for non-parametric testing were analyzed for HTDs, exceeding the required percentage. The two (2) samples that were tested, were randomly selected for HTD radionuclide analyses using the Microsoft Excel "RANDBETWEEN" function.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in Table 2.

The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the 5% requirement.

The LTP specifies that scanning will be performed along with random and judgmental measurements (samples) for a

Class 3

survey unit.

Approximately 10% of this survey unit was scanned. Scanning was biased to areas where contamination was previously located and remediated in 1980 (PIR 80-37). Table 4 provides a synopsis of the survey design.

Revision 0 10

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Table 4 -

Synopsis of the Survey Design (1)

Feature Design Criteria Basis Based on AutoCAD-LT Survey Unit Land Area 11,244 m2 and Visual Sample Plan calculations Type 1 and Type 2 errors 17 were 0.05, sigma was 0.039 pCi/g Cs-137 the Number of Measurements (15) non-parametric LBGR was adjusted to statistical testing samples 5.93 pCi/g Cs-137 to (2) biased samples maintain Relative Shift in the range of I and 3.

Grid Spacing NA Based on random sampling To achieve 19 mrem/yr TEDE (l to demonstrate Operational DCGL 6.01 pCi/g Cs-137 c

pae with equati compliance with Equation 2 of this Release Record The LTP specifies Scan Coverage Approximately 10% of the judgmental coverage for area Class 3 Survey Unit The Operational DCGL Soil Investigation Level 6.01 pCi/g Cs-137 meets the LTP criteria for a Class 3 survey unit (1) The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)

5.

SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Initially six (6) scan areas were established that constituted approximately 10% of the surface area of the Survey Unit 9506-0000. In January 2007, two (2) scan areas were absorbed into Survey Unit 9514-0000.

One (1) additional scan area was established in the redrawn survey unit. The total number of scan areas was five (5) and the total area scanned remained approximately 10% of the surface area. Grid lines, one (1) meter wide, were established in each of the five (5) scan areas. Background was established at Revision 0 I1I Revision 0 11

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD the beginning of each grid line, prior to scanning, using an Eberline E-600 with a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with the audio response.

Fifteen (15) soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Initially two (2) samples, 9506-0000-004F and 9506-0000-013F, were selected, at random for HTD radionuclide analysis by the off-site laboratory.

Sample 9506-0000-004F was absorbed into Survey Unit 9514-0000. Sample 9506-0000-019F was randomly selected to replace sample 9506-0000-004F.

Two (2) biased soil samples 9506-0000-016F and 9506-0000-017F were collected to be analyzed by the offsite laboratory for gamma spectroscopy.

The implementation of survey specific quality control measures included the collection of two (2) split samples at locations 9506-0000-002F and 9506-0000-008F for "split sample" analysis by the off-site laboratory.

6.

SURVEY RESULTS All field survey activities were conducted in November 2006 and January 2007.

The scan areas were scanned in accordance with the FSSP in November 2006 and January 2007. There were no areas of elevated activity identified during the scanning process. Table 5 provides an overview of sample scan locations.

Table 5 - Scan Results for Sample Measurement Locations Sample Highest Logged Action Level (2

Measurement Reading

> Action Level (2)

Location (kcpm)

(cpm) 1 5.55 6.43 NO 2

5.84 7.20 NO 5

6.84 7.89 NO 6

5.12 7.96 NO 7

6.92 8.25 NO 8

7.00 8.17 NO 9

6.28 7.38 NO 10 6.11 7.40 NO Revision 0 12

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Table 5 -

(continued)

Sample Highest Logged Action Level (1)

Measurement Reading (kcpm)

> Action Level (2)

Location (kcpm) 11 9.38 9.57 NO 12 8.68 10.8 NO 13 5.63 6.46 NO 14 7.07 8.15 NO 18 5.16 6.55 NO 19 6.25 7.37 NO 20 5.84 6.38 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the one (1) meter radius yielding the response above the action level (3) Sample locations #'s 3, 4, and 15 were absorbed into Survey Unit 9514-0000.

The scan areas, that comprised approximately 10% of the total surface area for the survey unit, were scanned for elevated radiation levels. Table 6 provides an overview of the scan area survey. Scan results are provided in.

Table 6-Scan Area Results Scan Range of Highest Logged Range of Action

>Action Area Logged Reading Reading Level (1)

Level (2)

(kcpm)

(kcpm)

(kcpm) 1,4-7 5.16 - 8.37 8.37 6.48 - 9.94 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) Scan areas #'s 2 and 3 were absorbed into Survey Unit 9514-0000. Scan area 7 was established to replace them.

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDC. Gamma spectroscopy results identified some radionuclides meeting the acceptance criteria for detection (i.e., a result greater than two (2) standard deviations Revision 0 13

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4.

Cesium-137 was identified in twelve (12) of the fifteen (15) samples. None of the samples exceeded the Operational DCGL.

Gamma spectroscopy sample analysis did not require further investigation.

A summary of the sample results is provided in Table 7.

Table 7 -

Summary of Soil Sample Results Cs-137 Fraction of the pCilg Operational DCGL (1) 9506-0000-001F 1.82E-01 0.030 9506-0000-002F 8.15E-02 0.013 9506-0000-005F 1.63E-01 0.027 9506-0000-006F 5.09E-02 0.008 9506-0000-007F 4.72E-02 0.008 9506-0000-008F 5.52E-02 0.009 9506-0000-009F 6.37E-02 0.011 9506-0000-01OF 4.98E-02 0.008 9506-0000-01 IF

-2.11 E-02

-0.003 9506-0000-012F 2.53E-02 0.004 9506-0000-013F 2.52E-01 0.042 9506-0000-014F 4.40E-02 0.007 9506-0000-018F 1.76E-01 0.029 9506-0000-019F 6.12E-02 0.010 9506-0000-020F 1.31E-01 0.022 (1)

The Operational DCGLs from Table 2 is 6.01 pCi/g for Cs-137 to achieve nineteen (19) mrem/yr TEDE.

The off-site laboratory also processed two (2) samples for HTD analyses as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. Gamma spectroscopy results identified some radionuclides meeting the acceptance criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4.

All analyses met the required MDC.

Revision 0 14 Revision 0 14

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD Two (2) biased sample were collected at locations selected by FSS Supervision based on professional judgment and observation.

Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. The samples were a very small fraction of the Operational DCGL. No further action or investigations were required. A summary of the sample results is provided in Table 8.

Table 8 -

Biased Sample Results Cs-137 Fraction of the Sample Number pCi/g Operational DCGL o 95060000-016F 1.90E-01 0.032 95060000-017F 3.91E-02 0.006 (1)

The Operational DCGLs from Table 2 is 6.01 pCi/g for Cs-137 to achieve a TEDE of nineteen (19) mrem/yr.

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

The data was evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between the field split results for both of the "split sample" pairs tested.

The sample analysis vendor, General Engineering Laboratories (GEL) -

Charleston, South Carolina, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS Sample investigation levels were not exceeded for this unit. Consequently, no investigations were performed.

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS.

Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.

Revision 0 15

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN Addendum #1 was drafted to address sample location, 9506-0000-013F that was underwater at the time the FSSP was initiated. The addendum was not used due to receding water. Sample location 9506-0000-013F was taken at its original randomly selected location.

Addendum #2 was drafted to address the change in the south boundary of Survey Unit 9506-0000, the locations of three (3) of the fifteen (15) samples that were used for non-parametric statistical testing and two (2) scan areas were absorbed into Survey Unit 9514-0000 and a new scan area was established. Approximately eight hundred seventy six square meters (876 M 2) of the survey unit were absorbed by Survey Unit 9514-0000

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment," for completeness and consistency. The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.

Documentation was complete and legible.

Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). See Table 9.

Table 9 -

Basic Statistical Quantities for Cs-137 from the Final Status Survey Cs-137 pCi/g DCGLop:

6.01E+00 Minimum Value:

-2.11 E-02 Maximum Value:

2.52E-01 Mean:

7.99E-02 Median:

5.52E-02 Standard Deviation:

7.11 E-02 Revision 0 16

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

The range of the data was about 2.81 standard deviations. The difference between the mean and median was 38.6% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.21.

All data, assessments, and graphical representations are provided in.

12.

ANOMALIES No anomalies were noted in the performance of this FSS.

13.

CONCLUSION Survey Unit 9506-0000 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation were not required.

The sample data passed the Sign Test. The null hypothesis was rejected.

Graphical representation of data indicates some positive skewness that is probably due to the differences in terrain and the collection of runoff. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as Class 3.

The dose contribution from soil is 0.253 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). The dose contribution from existing groundwater is zero (0) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no radioactive concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024).

The dose contribution from future groundwater, the third dose component, is therefore zero (0) mrem/yr TEDE.

Revision 0 17

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD The average total dose from residual radioactivity in this survey unit is 0.253 mrem/yr TEDE.

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 18

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 1 (FIGURES)

00

-oen -t f S* -

N2u'g J / Ear"W -.WJ&14 1N k;lz

-I rG-WMW RM-R Figure 1 (Connecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9506-0000 Fcbmxty 2007

-,/

-R-mw.

a 0.025 0.047 a

0.0,49 0.063 0.055 0.050 NAD27C.UIvoMW S" Ph-S384.

A 0.081 z0.163 9512-0000 9506-0000 Final Status Survey Cesiam-137 Posting Plot

7 14 9512-0000 Cnnecticut Yankee Atomic Power Company Sunvey Unit 9506-0000

' ~WtLw~d

'4 0

so to

ý F-EW~~~

C.Wd.fl-NAD2C.lmdcu 9512-0000 Connecticut Yankee Atomic Power Company 9506-0000 Area Absorbed into Survey Unit 9514-0000

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9506-0000 Sample Name

Background

Action Level Results Above Log Date Log Time E600 SIN Probe S/N (CPM) fCPM)

(cpm)

AL 9506-00-SL-00-01-0 5.38E+03 6.43E+03 5.55E+03 11/10/2006 8:05:00 1111 1004 9506-00-SL-00-02-0 6.09E+03 7.20E+03 5.84E+03 11/10/2006 7:41:00 1111 1004 9506-00-SL-00-05-0 6.72E+03 7.89E+03 6.84E+03 11/10/2006 7:33:00 1111 1004 9506-00-SL-00-06-0 6.78E+03 7.96E+03 5.12E+03 11/9/2006 10:48:00 1107 1003 9506-00-SL-00-07-0 7.05E+03 8.25E+03 6.92E+03 11/13/2006 8:02:00 1116 1006 9506-00-SL-00-08-0 6.98E+03 8.17E+03 7.OOE+03 11/9/2006 13:34:00 1107 1003 9506-00-SL-00-09-0 6.25E+03 7.38E+03 6.28E+03 11/9/2006 13:46:00 1107 1003 9506-00-SL-00-10-0 6.27E+03 7.40E+03 6.11E+03 11/9/2006 13:55:00 1107 1003 9506-00-SL-00-11-0 8.27E+03 9.57E+03 9.38E+03 11/9/2006 14:07:00 1107 1003 9506-00-SL-00-12-0 9.37E+03 1.08E+04 8.68E+03 11/9/2006 14:19:00 1107 1003 9506-00-SL-00-13-0 5.41E+03 6.46E+03 5.63E+03 11/13/2006 13:19:00 1116 1006 9506-00-SL-00-14-0 6.96E+03 8.15E+03 7.07E+03 11/9/2006 10:57:00 1107 1003 9506-00-SL-00-18-0 5.49E+03 6.55E+03 5.16E+03 1/11/2007 9:51:00 1112 1013 9506-00-SL-00-19-0 6.24E+03 7.37E+03 6.25E+03 1/11/2007 8:21:00 1112 1013 9506-00-SL-00-20-0 5.34E+03 6.38E+03 5.84E+03 1/11/2007 13:59:00 1112 1013

Survey Release Record Scan Area Results Survey Unit 9506-0000 9506-0000 SCAN AREA 1

Background

Sample Name (cmn 9506-00-SC-01-01-0 6.96E+03 9506-00-SC-01-02-0 6.18E+03 9506-00-SC-01-03-0 7.06E+03 9506-00-SC-01-04-0 6.52E+03 Action Level (cpm) 8.15E+03 7.30E+03 8.26E+03 7.67E+03 Results 6.50E+03 5.45E+03 5.89E+03 6.OOE+03 Above AL Log Date 11/10/2006 11/10/2006 11/10/2006 11/10/2006 Log Time 8:05:00 7:41:00 12:54:00 13:03:00 E600 SIN 1111 1111 1111 1111 Probe SIN 1004 1004 1004 1004 9506-0000 SCAN AREA 4 9506-00-SC-04-01-0 9506-00-SC-04-02-0 9506-00-SC-04-03-0 9506-00-SC-04-04-0 9506-00-SC-04-05-0 9506-0000 SCAN AREA 5 7.30E+03 7.69E+03 7.39E+03 6.04E+03 7.19E+03 8.52E+03 8.94E+03 8.62E+03 7.15E+03 8.40E+03 6.42E+03 7.OOE+03 7.08E+03 6.40E+03 6.71 E+03 11/10/2006 11/10/2006 11/10/2006 11/10/2006 11/10/2006 12:58:00 12:59:00 13:01:00 13:03:00 13:06:00 1111 1111 1111 1111 1111 1004 1004 1004 1004 1004 9506-00-SC-05-01-0 9506-00-SC-05-02-0 9506-00-SC-05-03-0 9506-00-SC-05-04-0 9506-00-SC-05-05-0 9506-00-SC-05-06-0 9506-00-SC-05-07-0 9506-00-SC-05-08-0 8.84E+03 7.23E+03 7.94E+03 8.15E+03 8.42E+03 8.61 E+03 7.85E+03 7.51 E+03 1,02E+04 8.44E+03 9.21 E+03 9.44E+03 9.73E+03 9.94E+03 9.12E+03 8.75E+03 7.73E+03 7.33E+03 7.27E+03 7.72E+03 8.37E+03 7.37E+03 7.20E+03 7.17E+03 11/10/2006 11/10/2006 11/10/2006 11/10/2006 11/10/2006 11/10/2006 11/10/2006 11/10/2006 13:17:00 13:19:00 13:23:00 13:24:00 13:27:00 13:28:00 13:30:00 13:31:00 1111 1111 1111 1111 1111 1111 1111 1111 1004 1004 1004 1004 1004 1004 1004 1004 9506-0000 SCAN AREA 6 9506-00-SC-06-01 -0 9506-00-SC-06-02-0 9506-00-SC-06-03-0 9506-00-SC-06-04-0 9506-0000 SCAN AREA 7 9506-00-SC-07-01-0 9506-00-SC-07-02-0 9506-00-SC-07-03-0 6.72E+03 6.28E+03 5.43E+03 5.95E+03 7.56E+03 8.18E+03 7.18E+03 7.89E+03 7.41 E+03 6.48E+03 7.05E+03 8.80E+03 9.47E+03 8.39E+03 7.25E+03 6.80E+03 5.59E+03 6.62E+03 7.53E+03 8.46E+03 7.90E+03 11/13/2006 11/13/2006 11/13/2006 11/13/2006 11/13/2006 1/11/2007 1/11/2007 8:12:00 8:14:00 8:16:00 8:18:00 8:12:00 8:15:00 8:19:00 1116 1116 1116 1116 1117 1117 1117 1006 1006 1006 1006 1008 1008 1008

Survey Release Record Scan Area Results Survey Unit 9506-0000 9506-00-SC-07-04-0 7.58E+03 8.82E+03 7.56E+03 1/11/2007 8:22:00 1117 1008 9506-00-SC-07-05-0 7.08E+03 8.28E+03 6.86E+03 1/11/2007 8:26:00 1117 1008 9506-00-SC-07-06-0 7.02E+03 8.22E+03 6.62E+03 1/11/2007 8:29:00 1117 1008 9506-00-SC-07-07-0 6.57E+03 7.73E+03 6.66E+03 1/11/2007 10:01:00 1117 1008 9506-00-SC-07-08-0 6.85E+03 8.03E+03 6.90E+03 1/11/2007 10:04:00 1117 1008 9506-00-SC-07-09-0 6.43E+03 7.58E+03 6.41 E+03 1/11/2007 10:06:00 1117 1008 9506-00-SC-07-10-0 6.79E+03 7.97E+03 6.62E+03 1/11/2007 10:09:00 1117 1008 9506-00-SC-07-11-0 7.06E+03 8.26E+03 7.28E+03 1/11/2007 10:12:00 1117 1008 9506-00-SC-07-12-0 7.11E+03 8.31E+03 6.82E+03 1/11/2007 10:14:00 1117 1008 9506-00-SC-07-13-0 6.83E+03 8.01E+03 6.56E+03 1/11/2007 10:17:00 1117 1008 9506-00-SC-07-14-0 6.51E+03 7.66E+03 6.57E+03 1/11/2007 10:20:00 1117 1008 9506-00-SC-07-15-0 6.70E+03 7.87E+03 7.14E+03 1/11/2007 10:22:00 1117 1008

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 176227 SDG: MSR#06-1479 November 21, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on November 16, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 176227001 176227002 176227003 176227004 176227005 176227006 176227007 176227008 176227009 176227010 176227011 176227012 176227013 176227014 176227015 176227016 176227017 176227018 176227019 Sample Description 9506-0000-OOIF 9506-0000-002F 9506-0000-002FS 9506-0000-003F 9506-0000-004F 9506-0000-005F 9506-0000-006F 9506-0000-007F 9506-0000-008F 9506-0000-008FS 9506-0000-009F 9506-0000-01OF 9506-0000-01 1F 9506-0000-012F 9506-0000-013F 9506-0000-014F 9506-0000-015F 9506-0000-016F 9506-0000-017F Items of Note There are no items to note.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 - Faxa43) 766-1178 www.gel.com

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Seventeen soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Chte MJones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417, 2040 Savage Road (29407)

Phone (843) 556-8171

  • Faxa43) 766-1178 www.gel.com

List of current GEL Certifications as of 21 November 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (-L/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 4

Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00664 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones U

Priority: [130 D. Z 14 D. [] 7 D.

Container Sample Size-Media Type

&Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9506-0000-001F 11/10/06 0815 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-002F 11/10/06 0755 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-002FS 11/10/06 0755 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-003F 11/9/06 1305 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-004F 11/9/06 1312 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-005F 11/10/06 0735 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-006F 11/9/06 1053 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-007F 11/13/06 0805 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-008F 11/9/06 1340 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-008FS 11/9/06 1340 TS G

BP X

RDL's: H-3: 3.0 pCi/g NOTES: PO #: 002332 MSR #: 06-1479 SSWP# NA SLTP QA

[ERadwaste QA R Non QA Samples Shipped Via:

Z Fed Ex D] UPS

[1 Hand El Other Internal C gntaine Temp.: _

Deg. C Custd Sealed?

Custody Seal Intact?

YK' N

1) R q

D ate/Time By Date/Time

3) 1(

lqushý B/

'ate/Time

4) Received By Date/Time Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00665 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C

Priority: [] 30 D. Z 14 D. E] 7 D.

Container Sample Size-

+

Media Type

&Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9506-0000-009F 11/9/06 1354 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-01OF 11/9/06 1358 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-011F 11/9/06 1420 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-012F 11/9/06 1425 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-013F 11/13/06 1320 TS G

BP X

RDL's: H-3:3.0 pCi/g 9506-0000-014F 11/9/06 1056 TS G

BP X

RDL's: H-3:3.0 pCi/g 9506-0000-015F 11/9/06 1130 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-016F 11/9/06 1125 TS G

BP X

RDL's: H-3: 3.0 pCi/g 9506-0000-017F 11/10/06 0825 TS G

BP X

RDL's: H-3:3.0 pCi/g NOTES: PO #: 002332 MSR #: 06-1479 SSWP# NA SLTP QA 13 Radwaste QA 13 Non QA

1) Re d

y D e/Time

2) R ived ByDateTime
3) elinquisýe y

ate/Time

4) Received By Date/Time Samples Shipped Via:

Z Fed Ex 13 UPS 13 Hand 13 Other Internal Container Temp.: _x Deg. C Custody Sealed?

Y*

NO Custody Seal Intact?

Y' N 0 Bill of Lading #

',: 3allilel 11-, 1ýbbUc

Subject:

RE: Sample ID Issue From: "Ai-thur L. Hammond" <Hammond@ CYAPCO.com>

Date: Thu, 16 Nov 2006 15:19:28 -0500 To: "ama01354" <amanda.rasco @ gel.com>

Amanda, The sample ID should read 9506-0000-009F.

Thank you, Arthur


Original Message-From: ama01354 [1]

Sent: Thursday, November 16, 2006 1:52 PM To: Arthur L.

Hammond Cc: Cheryl Jones

Subject:

Sample ID Issue

Arthur, From the samples we received today from MSR#06-1479, sample ID #

9506-0000-009F reads 9506-0000-009 (without an F) on the sample container-Please verify that sample ID should read 9506-0000-009F.

Thank You, Amanda Rasco Amanda J.

Rasco Project Manager Assistant General Engineering Laboratories, LLC 2040 Savage Road Charleston, SC (USA) 29407 Direct: 843.769.7376 x 4297 Main:

843.556.8171 Fax:

843.766.1178 E-mail: Amanda.Rasco@gel.com Web:

www.gel.com The information contained in this message is confidential and is intended only for the use of the individual or firm of record.

If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the pages that follow.

Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.

11/16/2006 3:24 PYV

Connecticut Yankee CY.ISC-SOW-01 Stateme nt of Work for Analytical Lab Services Figure 1. -Sample Check-in List DatedTime Received:""

SDG#:

Work Order Number:

Shipping Cdntainer ID:J Th)I AAý0

) I Chain of Custody 0

(

C)Y((,

1.

Custody Seals ori shipping container intact?..

Yes.

O[]

2.

Custody Seals dated and signed?

Yes'

.No[]

3.

Chain-of-Custody record present? ".yes N*o[

4.

Cooler temperature 1

5.

Vermniculite/packing materials is:-

Wet [] Dry

6.

- Number of samples in shipping container.

0/

7.

Sample holding times exceeded?

Yes(] No

8. Samples have:

---_hazard labels custody seals

=appropriate sample labels

9. Samples are:

L in good condition

-leaking broken have air bubbles 10.

11.

Were any anomalies identified in sample receipt

.Description of anomalies.(include sample numbi Yes[

No4

  • L*

Im

  • 1 1

I Sample Custodian/Laboratory:

Telephoned to:.

"_- z =-U_= -

On

_Date.

6?..,

t0

yEN/,

SAMPLE RECEIPT & REVIEW FORM PM use only Client:

I t

ISDG/ARCOC/Work Order:

(_?ZG 22 -

Date Received:

"PM(A)

Review (ensure t°coem are resolved prior to signing):

Received By:

Sample Receipt Criteria z

z Comments/Qualifiers (Required for Non-Conformin Items) 1 Shipping containers received intact Circle Applicable: seals broken damaged container leaking conta* 4r other (describe) and sealed?

7 Samples requiring cold Circle Coolant #

ice bags blue ice dry ie none other describe) 2 preservation within (4 +/- 2 C)?

lRecord 'preservation method.

3 Chain of custody documents1/

included with shipment?

Sample containers intact and l

Circle Applicable: seals. broken da Qed container leaking container other (describe) sealed?

/__

5 Samples requiring chemical Sample ID's, containers ft 6ed and observed pH:

preservation at proper pH?

7 6 VOA vials free of headspace Sample ID's and c Itainers affected:

6 (defined as < 6mm bubble)?

/

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

/

8 Samples received within holding I/

Id's and tests affected:

time?

Sample ID's on COC match ID's Sample lD's and containers affected:

on bottles?

10 Date & time on COC match date Sample UD's affected:

& time on bottles?

___1________Sample_____M's___affected:____

11 Number of containers rec ed Sample D's affected:

match number indicate on COO?

COC form is prope St signed in relinquished/recp*ved sections?

Air Bill,TJ cking #'s, &

1Additio Comments Co_.2o( 2 O0(0 (0

V 10 M RSO RAD Receipt #

  • If > x2 area background is observed on samples identified as "non-Suspected Hazard Information cc =

Su e H r w regulated/non-radioactive", contact the Radiation Safety group for further hinvestigation.

A Radiological Classification?

Maximum Counts Observed*:

B PCB Regulated?

L/'

Shipped as DOT Hazardous C Material? If yes, contact Waste1 Hazard Class Shipped:

Manager or ESH Manager.

UN#:

D Regulated as a Foreign Soil?'

PM (or PMA) review of Hazard classification:

Initials Date: it (a o~ o to V

I a

  • uorre~ticui rara~ee t., n n c tic u t Y a n k e e Statement of Work for Analytical Lab Services

-CY-ISC-SOW-O01 Figure 1. Sample Check-in List.

Date/Time Received:-

Q SDG#:

V

~

i

(

T

-Work Order Number:----!

2.~i S h ip p in g

  • i n e r ID :.

C h a in W*

C u.5d I.

Custody Seals ouT shipping container intact?...

Yes No[]

2.

Custody Seals dated and. signed?

Yes*

No []-

3.

Chain-of-Custody record present? "

Yes No [ ]

  • 0
4.

Cooler temperature

5.

Vermiculite/packing materials is:'

Wet [] Dry 6..

  • Number ofsamples in shipping container:
7.

Sample ho times e d

Y

7. Sml olding times exceeded?

Yes []N

8. Samples have:

.i~itape---hazard labels

-~custody seals

-..appropriate sample labels

9. Samples are:

good condition

-l......eaking

.;--roke"...have air bubbles

10.

Were any anomalies identified in sample receipt?

Yes No f I S11..

.Ds~cription of anomalies (include sample numbers):_-

-am.pleCustodian/Laboratory;

.. mple

  • , "
  • I

/lL.

Date-Telephoned to On" By

-On

SAMPLE RECEIPT & REVIEW FORM 9

PM use only Client:

(

SDG/ARCOC/Work Order: [

7 Date Received:

PM(A) Review (ensure noniconfoyningitems are resolved prior to signing):

Received By:

I Sample Receipt Criteria z

z Comments/Qualifiers (Required for Non-Conforming X

I s)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking contai other (describe) and sealed?

/

Samples requiring cold Circle Coolant #

ice bags blue ice dr 'ee none other describe) 2 preservation within (4 +/- 2 C)?

Record preservation method.

3 Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable: seals b en damaged container leaking container other (describe) sealed?

1 5 Samples requiring chemical Sample ID's.

ainers affected and observed pH:

preservation at proper pH?

Z_

6 VOA vials free of headspace Sa hTe ID's and containers affected:

_ (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding id's and tests affected:

time?/1 9 Sample IDOs on COC matc 1

Sample ID's and containers affected:

on bottles?

/_1 10&Date & time on CO*

atch date 1Sample ID's affected:

&time on bottles 7___________________________

Number of co ainers received Sample ID's affected:

match num;rindicated on COC?

12 COC foK is properly signed in lrelinished/received sections?

14 /ir Bill,Tracking #'s, &

Additional Comments C

2co( -cc(

,S RSORADReceipt#

S e r r

  • If > x2 area background is observed on samples identified as "non-Suspected Hazard Information
  • -Z -Z Z =

El regulated/non-radioactive", contact the Radiation Safety group for further Z investigation.

A Radiological Classification?

Maximum Counts Observed*:

0 ( paY B PCB Regulated?

Shipped as DOT Hazardous HaCsSi1 C Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager.

L lUN#:

- PRegulate as a Foreign So cl L.PM (or PMA) review of Hazard classification:

1,Initials Date:

I I I, Iot LI I

wcl: Ke: ýiampie it) lssuej Web:

www.cfel.com The information contained in this message is confidential and is intended only for the use of the individual or firm of record.

If you are not the intended recipient and have received this message in error, you areasked not to copy or distribute any of the pages that follow.

Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.

Re SContent-Type:

message/rfc822 Re: Sample ID Issue i, Is 1

Content-Encoding: 7bit 13 2 of 2 11/21/2006 4:50 PN

Data Review Qualifier Definitions 14

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

.10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171 - Fa"3) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 16

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 176227 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 589568 589087 589083 Sample ID 176227005 176227015 1201231904 1201231905 1201231906 1201231907 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

17

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 18

Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 589569 589087 589083 Sample ID 176227005 176227015 1201231908 1201231909 1201231910 1201231911 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

19

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-11-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 589570 589087 589083 20

Sample ID Client ID 176227005 9506-0000-004F 176227015 9506-0000-013F 1201231912 Method Blank (MB) 12012319] 3 176227005(9506-0000-004F) Sample Duplicate (DUP) 1201231914 176227005(9506-0000-004F) Matrix Spike (MS) 1201231915 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 21

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 589209 589083 22

Sample ID 176227001 176227002 176227003 176227004 176227005 176227006 176227007 176227008 176227009 176227010 176227011 176227012 176227013 176227014 176227015 176227016 176227017 176227018 176227019 1201231039 1201231040 1201231041 Client ID 9506-0000-001F 9506-0000-002F 9506-0000-002FS 9506-0000-003F 9506-0000-004F 9506-0000-005F 9506-0000-006F 9506-0000-007F 9506-0000-008F 9506-0000-008FS 9506-0000-009F 9506-0000-01OF 9506-0000-01 IF 9506-0000-012F 9506-0000-013F 9506-0000-014F 9506-0000-015F 9506-0000-016F 9506-0000-017F Method Blank (MB) 176227001(9506-0000-OO1F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227001 (9506-0000-001F).

QC Information 23

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample UI U1 UI Data rejected due to high counting uncertainty.

Data rejected due to high peak-width.

Bismuth-212 Cesium-134 Actinium-228 Cesium-134 Data rejected due to low abundance.

176227012 176227015 176227012 1201231039 176227006 176227009 176227010 176227013 176227014 176227019 1201231040 1201231039 UI Data rejected due to no valid peak.

Potassium-40 Method/Analysis Information 24

Product:

GFPC, Sr90, solid - 0.025 pCi/g Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 589170 589087 589083 Sample ED 176227005 176227015 1201230916 1201230917 1201230918 1201230919 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information 25

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 176227005 (9506-0000-004F) and 176227015 (9506-0000-013F) were recounted due to a negative result greater than three times the error.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

Analytical Batch Number:

Sample ID 176227005 176227015 1201230758 1201230759 1201230760 1201230761 DOE EML HASL-300, Tc-02-RC Modified 589096 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 26

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis The batch was recounted due to low matrix spike recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 385910 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 176227005 and 176227015 into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures. Reporting results.

Additional Comments Additional comments were not required for this sample set.

27

Qualifier information Manual qualifiers were not required, Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 589223 589087 589083 Sample ID 176227005 176227015 1201231091 1201231092 1201231093 1201231094 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

28

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

589224 Prep Batch Number:

589087 Dry Soil Prep GL-RAD-A-021 Batch Number:

589083 29

Sample ED 176227005 176227015 1201231095 1201231096 1201231097 1201231098 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 30

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method:

Analytical Batch Number:

Sample ID 176227005 176227015 1201230745 1201230746 1201230747 1201230748 EPA 906.0 Modified 589090 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

31

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis The batch was recounted due to a low Matrix spike recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Analytical Batch Number:

Sample ID 176227005 176227015 1201230741 1201230742 1201230743 1201230744 Liquid Scint C14, Solid AI1,FSS EPA EERF C-01 Modified 589089 Client ID 9506-0000-004F 9506-0000-013F Method Blank (MB) 176227005(9506-0000-004F) Sample Duplicate (DUP) 176227005(9506-0000-004F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 32

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176227005 (9506-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 384387 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 176227 005,015 into the batch prior to analysis, however the samples did remain

.in their custody at all times. 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Additional Comments Additional comments were not required for this sample set.

33

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

-a,,ow ( fl 2-2 ((ýD Reviewer/Date:

34

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:

384387 Revision No.: 1 COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

17-NOV-06 Radiochemistry Specifications Process Instrument Type:

Test / Method:

Matrix Type:

Client Code:

LSC EPA EERF C-01 Modified Solid YANK Batch ID:

Sample Numbers:

589089 See Below Potentially affected work order(s)(SDG): 176227(MSR#06-1479)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan the samples 176227 005,015 into the batch
1. The error has been corrected and the analyst has been instructed on the prior to analysis, however the samples did remain in their custody at all proper scanning procedures.

times.

Originator's Name:

Amy Scott Quality Review:

Data Validator/Group Leader:

Melanie Aycock 17-NOV-06 17-NOV-06 Director:

Page 1 35

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:

385910 Revision No.:

COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

22-NOV-06 Radiochemistry Specifications Process Instrument Type:

Test / Method:

Matrix Type:

Client Code:

LSC DOE EML HASL-300, Tc-02-RC Solid YANK Modified Batch ID:

Sample Numbers:

589096 See Below Potentially affected work order(s)(SDG): 176227(MSR#06-1479)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan the samples 176227005 and 176227015 into
1. The error has been corrected and the analyst has been instructed on the the batch prior to analysis, however the samples did remain in their proper scanning procedures. Reporting results.

custody at all times.

Originator's Name:

Melanie Aycock Quality Review:

Data Validator/Group Leader:

Heather Anderson 22-NOV-06 22-NOV-06 Director:

Page 1 36

SAMPLE DATA

SUMMARY

37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1479 GEL Work Order: 176227 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Report Date: November 22, 2006 Project:

Soils PO# 002332 Client Sample ID:

9506-0000-00IF Project:

YANK01204 Sample ID:

176227001 Client ID:

YANKO0I Matrix:

TS Vol. Recv.:

Collect Date:

10-NOV-06 Receive Date:

16-NOV-06 Collector:

Client Moisture:

31.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.525

+/-0.210 0.0606

+/-0.210 0.133 pCi/g MJHI 11/21/06 0551 589209 1

Americium-241 U

0.0255

+1-0.105 0.0844

+/-0.105 0.176 pCi/g Bismuth-212 0.496

+/-0.274 0.133

+/-0.274 0.287 pCi/g Bismuth-214 0.329

+/-0.0712 0.0386 +/-0.0712 0.0819 pCi/g Cesium-134 U

0.0173

+/-0.0243 0.0219 +/-0.0243 0.0471 pCi/g Cesium-137 0.182

+/-0.0473 0.0158 +/-0.0473 0.0344 pCi/g Cobalt-60 U 0.000215

+/-0.0196 0.0165 +/-0.0196 0.0375 pCi/g Europium-152 U

0.0228

+/-0.0508 0.0442 +/-0.0508 0.0938 pCi/g Europium-154 U

0.0472

+/-0.0668 0.0613 +/-0.0668 0.135 pCi/g Europium-155 U

0.0144

+/-0.0535 0,0496 +/-0.0535 0.103 pCi/g Lead-212 0.531

+/-0.0594 0.0262 +/-0.0594 0.0549 pCi/g Lead-214 0.396

+/-0.0891 0.0331 +/-0.0891 0.0701 pCi/g Manganese-54 U

0.0046

+/-0.0213 0.0181 +/-0.0213 0.0393 pCilg Niobium-94 U8.600E-05

+/-0.0187 0.0159 +/-0.0187 0.0342 pCi/g Potassium-40 10.9

+/-0.895 0.181

+/-0.895 0.407 pCi/g Radium-226 0.329

+/-0.0712 0.0386 +/-0.0712 0.0819 pCi/g Silver-108m U

-0.0144

+/-0.0165 0.0135 +/-0.0165 0.0291 pCilg Thallium-208 0.164

+/-0.0416 0.0168 +/-0.0416 0.0362 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-001F Project:

YANK01204 Sample ID:

176227001 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product 13 Target analyte was detected in the associated blank

]3D Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-002F 176227002 TS 10-NOV-06 16-NOV-06 Client 33.5%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,So/id-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.938

+/-0.267 Americium-241 U

-0.018

+/-0.0431 Bismuth-212 0.539

+/-0.484 Bismuth-214 0.717

+/-0.155 Cesium-134 U

0.0451

+/-0.0369 Cesium-137 0.0815

+/-0.0564 Cobalt-60 U

0.00572

+/-0.034 Europium-152 U 0.000421

+/-0.0774 Europium-154 U

0.0463

+/-0.0913 Europium-155 U

0.104

+/-0.109 Lead-212 0.882

+/-0.0958 Lead-214 0.786

+/-0.131 Manganese-54 U

0.00716

+/-0.0339 Niobium-94 U

0.0318

+/-0.0243 Potassium-40 9.65

+/-1.30 Radium-226 0.717

+/-0.155 Silver-108m U

0.0189

+/-0.0271 Thallium-208 0.216

+/-0.0655 0.0893 0.0378 0.201 0.0477 0.0348 0.0353 0.0294 0.0679 0.0832 0.0593 0.0384 0.0507 0.0287 0.0261 0.206 0.0477 0.0248 0.0277

+/-0.267

+/-0.0431

+/-0.484

+/-0.155

+/-0.0369

+/-0.0564

+/-0.034

+/-0.0774

+/-0.0913

+/-0.109

+/-0.0958

+/-0.131

+/-0.0339

+/-0.0243

+/-1.30

+/-0.155

+/-0.0271

+/-0.0655 0.199 0.0784 0.442 0.104 0.0756 0.0756 0.0666 0.145 0.188 0.124 0.0808 0.108 0.0627 0.0568 0.492 0.104 0.0531 0.0599 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 0552 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 22, 2006 Client Sample ID:

Sample ID:

9506-0000-002F 176227002 Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result UI Rad Gamma Spec Analysis Gamnina,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.950 Americium-241 U

0.0179 Bismuth-212 0.746 Bismuth-214 0.780 Cesium-134 U

0.0028 Cesium-137 0.0941 Cobalt-60 U

0.0351 Europium-152 U

0.0448 Europium-154 U

0.0218 Europium-155 U

0.0962 Lead-212 0.802 Lead-214 0.812 Manganese-54 U

-0.0303 Niobium-94 U

-0.0199 Potassium-40 10.7 Radium-226 0.780 Silver-108m U -0.00365 Thallium-208 0.248 9506-0000-002FS 176227003 TS 10-NOV-06 16-NOV-06 Client 29.3%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.268 4/-0.0516

+/-0.501

+/-0.171

+/-0.045

+1-0.0551

+/-0.0423

+/-0.0925

+/-0.118

+/-0.112

+/-0.109

+/-0.164

+/-0.0419

+/-0.0396

+/-1.27

+/-0.171

+/-0.0335

+/-0.0805 0.125 0.0446 0.283 0.0608 0.0374 0.0396 0.0387 0.0796 0.101 0.0751 0.0587 0.0562 0.03.19 0.0317 0.253 0.0608 0.0291 0.0328

+/-0.268

+/-0.0516

+/-0.501

+/-0.171

+/-0.045

+/-0.0551

+/-0.0423

+/-0.0925

+/-0.118

+/-0.112

+/-0.109

+/-0.164

+/-0.0419

+/70.0396

+/-1.27

+/-0.171

+/-0.0335

+/-0.0805 0.271 0.0925 0.605 0.130 0.0807 0.0842 0.085 0.168 0.222 0.156 0.122 0.119 0.0691 0.0678 0.582 0.130 0.0617 0.070 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 0552 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22,2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-002FS Proiect:

YANK01204 Sample ID:

176227003 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma 'Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-003F 176227004 TS 09-NOV-06 16-NOV-06 Client 16.3%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gainma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.886

+/-0.219 Americium-241 U

0.00844

+/-0.0402 Bismuth-212 U

0.300

+/-0.273 Bismuth-214 0.405

+/-0.122 Cesium-134 U

0.025

+/-0.0334 Cesium-137 0.143

+/-0.0542 Cobalt-60 U

0.0436

+/-0.036 Europium-152 U

0.00908

+/-0.0748 Europium-154 U

0.103

+/-0.109 Europium-155 U

0.0477

+/-0.0592 Lead-212 0.563

+/-0.0805 Lead-214 0.429

+/-0.0939 Manganese-54 U

0.0381

+/-0.0303 Niobium-94 U

-0.0188

+/-0.0275 Potassium-40 10.6

+/-1.14 Radium-226 0.405

+/-0.122 Silver-108m U -0.00901

+/-0.0256 Thallium-208 0.185

+/-0.0616 0.0898 0.0312 0.191 0.0434 0.0306 0.0256 0.0344 0.0565 0.100 0.0522 0.0324 0.0424 0.028 0.0224 0.239 0.0434 0.0212 0.0227

+/-0.219

+/-0.0402

+/-0.273

+/-0.122

+/-0.0334

+/-0.0542

+/-0.036

+/-0.0748

+/-0.109

+/-0.0592

+/-0.0805

+/-0.0939

+/-0.0303

+/-0.0275

+/-1.14

+/-0.122

+/-0.0256

+/-0.0616 0.179 0,0624 0.382 0.0867 0.0611 0.0511 0.0688 0.113 0.200 0.104 0.0648 0.0848 0.0559 0.0448 0.477 0.0867 0.0423 0.0454 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 0555 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-003F Project:

YANK01204 Sample ID:

176227004 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-004F 176227005 TS 09-NOV-06 16-NOV-06 Client 9.85%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec An241, Cn, Solid ALL FSS Americium-241 U

0.0532

+/-0.0844 0.0268 +/-0.0847 Curium-242 Curium-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 Plutonium-239/240 Liquid Scint Pu241, Solid-ALL P Plutonium-241 U

0.00

+/-0.0611 0.00 +/-0.0611 U -0.00717

+/-0.0141 0.0268 +/-0.0141 U

0.0186

+/-0.0741 U

-0.0243

+/-0.0831 0.0454 +/-0.0741 0.085 +/-0.0831 U

-0.362

+/-6.41 5.40

+/-6.41 Rad Gamma Spec Analysis Ganuna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.526

+/-0.121 Americium-241 U

-0.0405

+/-0.0881 Bismuth-212 0.346

+/-0.190 Bismuth-214 0.454

+/-0.0646 Cesium-134 U

0.0307

+/-0.0226 Cesium-137 U

0.0241

+/-0.0184 Cobalt-60 U-0.000174

+/-0.0136 Europium-152 U

0.0039

+/-0.0373 Europium-154 U

-0.0103

+/-0.0459 Europium-155 U

0.0799

+/-0.0638 Lead-212 0.508

+/-0.045 Lead-214 0.504

+/-0.0595 Manganese-54 U

0.00617

+/-0.0148 Niobium-94 U -0.00177

+/-0.0124 Potassium-40 8.92

+/-0.598 Radium-226 0.454

+/-0.0646 Silver-108m U -0.00755

+/-0.0128 Thallium-208 0.170

+/-0.0325 Rad Gas Flow Proportional Counting 0.0415 0.0746 0.0942 0.0262 0.0153 0.0121 0.0117 0.0337 0.0331 0.0398 0.0198 0.0214 0.0132 0.0109 0.104 0.0262 0.0108 0.0125

+/-0.121

+/-0,0881

+/-0.190

+/-0.0646

+/-0.0226

+/-0.0184

+/-0.0136

+/-0.0373

+/-0.0459

+1-0.0638

+/-0.045

+/-0.0595

+/-0.0148

+/-0.0124

+/-0.598

+/-0.0646

+/-0.0128

+/-0.0325 0.135 0.0845 0.135 0.188 0.267 11.4 0.0891 0.155 0.200 0.055 0.0324 0.0256 0.0257 0.0705 0.0723 0.0827 0.0412 0.045 0.0279 0.0231 0.230 0.055 0.0229 0.0263 0.020 pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 11/19/060732 589568 1

1 MXA 11/19/06 0732 589569 2

1 MXA 11/21/06 1044 589570 3

1 MJH1 11/21/06 0552 589209 4

GFPC, Sr90, solid - O.025pCilg Strontium-90 U

-0.0138 Rad Liquid Scintillation Analysis

+/-0.00986 0.00927 +/-0.00986 KSD1 11/22/06 1156 589170 5

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

9506-0000-004F 176227005 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCilg Tritium U

1.09 Liquid Scint C14, Solid AllFSS Carbon-14 U

-0.117 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

6.46 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-0.892 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 0.599 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-1.24 0.952

+/-1.24

+/-0.114 0.0976

+/-0.114

+/-33.1 24.6

+/-33.1

+/-4.43 3.74

+/-4.43

+/-0.253 0.195

+/-0.253 2.08 0.199 51.6 pCi/g pCi/g pCi/g DFAI 11/21/06 0933 589090 7

AXD2 11/16/06 1728 589089 9

MXPI 11/21/06 0014 589223 IC MXP1 11/20/06 1918 589224 11 KXR1 11/21/06 1252 589096 12 7.73 pCi/g 0.403 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11-RC Modified 3

DOE EMIL HASL-300, Pu-1I1-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA 906.0 Modified 9

EPA EERF C-01 Modified 10 DOE RESL Fe-1, Modified 11 DOE RESL Ni-I, Modified 12 DOE EML HASL-300, Tc-02-RC Modified 13 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS 93 81 (15%-125%)

(15%-125%)

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

9506-0000-004F 176227005 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Plutonium-241 Strontium-90 Carrier/Tracer Recovery Iron-55 Nickel-63 Carrier/Tracer Recovery Technetium-99 Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FE GFPC, Sr9O, solid - 0.025 pCi/g GFPC, Sr90, solid - 0.025 pCi/g Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 97 62 62 70 89 89 84 84 (25%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-005F 176227006 TS 10-NOV-06 16-NOV-06 Client 16.4%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gaimna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.719

+/-0.111 Americium-241 U

0.0769

+/-0.0627 Bismuth-212 0.321

+/-0.219 Bismuth-214 0.579

+/-0.0756 Cesium-134 UI 0.00

+/-0.0229 Cesium-137 0.163

+/-0.0294 Cobalt-60 U-0.000332

+/-0.0162 Europium-152 U

-0.0293

+/-0.0431 Europium-154 U

0.0178

+/-0.0456 Europium-155 U

0.0666

+/-0.0645 Lead-212 0.715

+/-0.0505 Lead-214 0.690

+/-0.0762 Manganese-54 U

0.0208

+/-0.0245 Niobium-94 U -0.00268

+/-0.0152 Potassium-40 12.0

+/-0.718 Radium-226 0.579

+/-0.0756 Silver-108m U

0.00572

+/-0.0134 Thallium-208 0.230

+/-0.0306 0.050 0.0557 0.106 0.0261 0.0182 0.0154 0.0139 0.0361 0.0405 0.0426 0.0228 0.0267 0.0105 0.0128 0.116 0.0261 0.0123 0.0137

+/-0.111

+/-0.0627

+/-0.219

+/-0.0756

+/-0.0229

+/-0.0294

+/-0.0162

+/-0.0431

+/-0.0456

+/-0.0645

+/-0.0505

+/-0.0762

+/-0.0245

+/-0.0152

+/-0.718

+/-0.0756

+/-0.0134

+/-0.0306 0.106 0.115 0.224 0.0547 0.038 0.0323 0.0298 0.0751 0.0867 0.0877 0.0471 0.0556 0.0225 0.0268 0.252 0.0547 0.0256 0.0287 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 0713 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-005F Project:

YANK01204 Sample ID:

176227006 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-006F 176227007 TS 09-NOV-06 16-NOV-06 Client 17.3%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mte Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.580

+/-0.182 Americium-241 U

-0.0348

+/-0.0409 Bismuth-212 0.517

+/-0.411 Bismuth-214 0.579

+/-0.122 Cesium-134 U

0.0239

+/-0.042 Cesium-137 U

0.0509

+/-0.0594 Cobalt-60 U

0.00356

+/-0.033 Europium-152 U

-0.0356

+/-0.0719 Europium-154 U

-0.0584

+/-0.100 Europium-155 U

0.054

+/-0.0658 Lead-212 0.500

+/-0.0938 Lead-214 0.558

+/-0.131 Manganese-54 U

0.015

+/-0.0359 Niobium-94 U

0.0391

+/-0.0455 Potassium-40 10.1

+/-1.14 Radium-226 0.579

+/-0.122 Silver-108m U

0.0102

+/-0.026 Thallium-208 0.180

+/-0.0693 0.106 0.035 0.218 0.0506 0.035 0.026 0.0281 0.059 0.0786 0.0589 0.0498 0.0439 0.0312 0.0266 0.238 0.0506 0.0239 0.0248

+/-0.182

+/-0.0409

+/-0.411

+/-0.122

+/-0.042

+/-0.0594

+/-0.033

+/-0.0719

+/-0.100

+/-0.0658

+/-0.0938

+/-0.131

+/-0.0359

+/-0.0455

+/-1.14

+/-0.122

+/-0.026

+/-0.0693 0.228 0.0728 0.467 0.108 0.0747 0.056 0.0623 0.125 0.174 0.123 0.103 0.0933 0.0666 0.0567 0.536 0.108 0.0507 0.0533 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/21/06 0815 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-006F Project:

YANK01204 Sample ID:

176227007 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-007F 176227008 TS 13-NOV-06 16-NOV-06 Client 23.2%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.969

+/-0.216 Americium-241 U

0.0013

+/-0.0431 Bismuth-212 0.701

+/-0.306 Bismuth-214 0.723

+/-0.138 Cesium-134 U

0.0485

+/-0.0578 Cesium-137 U

0.0472

+/-0.0362 Cobalt-60 U

0.0168

+/-0.0324 Europium-152 U

0.102

+/-0.0903 Europium-154 U

-0.0507

+/-0.114 Europium-155 U

0.051

+/-0.067 Lead-212 0.822

+/-0.0995 Lead-214 0.774

+/-0.133 Manganese-54 U -0.00408

+/-0.0292 Niobium-94 U -0.00363

+/-0.027 Potassium-40 10.1

+/-1.04 Radium-226 0.723

+/-0.138 Silver-i08m U-0.000972

+/-0.0241 Thallium-208 0.314

+/-0.0658 0.085 0.034 0.170 0.0446 0.0364 0.0307 0.0289 0.0614 0.0911 0.0524 0.0309 0.0389 0.0249 0.0233 0.194 0.0446 0.0207 0.0213

+/-0.216

+/-0.0431

+/-0.306

+/-0.138

+/-0.0578

+/-0.0362

+/-0.0324

+/-0.0903

+/-0.114

+/-0.067

+/-0.0995

+/-0.133

+/-0.0292

+/-0.027

+/-1.04

+/-0.138

+/-0.0241

+/-0.0658 0.170 0.0679 0.339 0.0891 0.0727 0.0614 0.0577 0.123 0.182 0.105 0.0617 0.0778 0.0497 0.0467 0.388 0.0891 0.0414 0.0425 pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/060857 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The Wollowing Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-007F Proiect:

YANK01204 Sample ID:

176227008 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-008F 176227009 TS 09-NOV-06 16-NOV-06 Client 13.9%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gawnna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.691

+/-0.106 Americium-241 U

-0.0398

+/-0.0536 Bismuth-212 0.387

+/-0.211 Bismuth-214 0.469

+/-0.0614 Cesium-134 U1 0.00

+/-0.023 Cesium-137 0.0552

+/-0.022 Cobalt-60 U

0.0102

+/-0.0154 Europium-152 U

-0.0337

+/-0.0402 Europium-154 U

0.00291

+/-0.0453 Europium-155 U

-0.0216

+/-0.0453 Lead-212 0.625

+/-0.0463 Lead-214 0.542

+/-0.0662 Manganese-54 U -0.00139

+/-0.0153 Niobium-94 U

0.00383

+/-0.0155 Potassium-40 10.1

+/-0.580 Radium-226 0.469

+/-0.0614 Silver-108m U -0.0248

+/-0.0128 Thallium-208 0.197

+/-0.0319 0.0456 0.0495 0.0916 0.0238 0.016 0.013 0.014 0.0335 0.0394 0.0403 0.0194 0.0243 0.0133 0.0117 0.110 0.0238 0.0103 0.012

+/-0.106

+/-0.0536

+/-0.211

+/-0.0614

+/-0.023

+/-0.022

+/-0.0154

+/-0.0402

+/-0.0453

+/-0.0453

+/-0.0463

+/-0.0662

+/-0.0153

+/-0.0155

+/-0.580

+/-0.0614

+/-0.0128

+/-0.0319 0.0967 0.102 0.194 0.0499 0.0337 0.0273 0.0299 0.0699 0.0842 0.0831 0.0402 0.0507 0.028 0.0246 0.240 0.0499 0.0217 0.0253 pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1021 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-008F Proiect:

YANK01204 Sample ID:

176227009 Client ID:

YANKOO1 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-008FS 176227010 TS 09-NOV-06 16-NOV-06 Client 13.5%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GainmaSolid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228 0.564

+/-0.195 Americium-241 U

0.016

+/-0.0378 Bismuth-212 0.607

+/-0.340 Bismuth-214 0.576

+/-0.111 Cesium-134 UI 0.00

+/-0.0473 Cesium-137 0.0891

+/-0.034 Cobalt-60 U

0.0173

+/-0.0312 Europium-152 U

0.00431

+/-0.0709 Europium-154 U

-0.0812

+/-0.0959 Europium-155 U

0.0193

+/-0.0695 Lead-212 0.653

+/-0.0814 Lead-214 0.588

+/-0.0985 Manganese-54 U

-0.0103

+/-0.0319 Niobium-94 U

0.0106

+/-0.023 Potassium-40 9.36

+/-1.03 Radium-226 0.576

+/-0.111 Silver-108m U

-0.01

+/-0.0204 Thallium-208 0.264

+/-0.0493 0.0805 0.0309 0.163 0.0377 0.0324 0.0244 0.0279 0.0546 0.0721 0.0494 0.0277 0.038 0.0228 0.021 0.233 0.0377 0.0171 0.0196

+/-0.195

+/-0.0378

+/-0.340

+/-0.111

+/-0.0473

+/-0.034

+/-0.0312

+/-0.0709

+/-0.0959

+/-0.0695

+/-0.0814

+/-0.0985

+/-0.0319

+/-0.023

+/-1.03

+/-0.111

+/-0.0204

+/-0.0493 0.161 0.0617 0.326 0.0754 0.0647 0.0488 0.0558 0.109 0.144 0.0988 0.0553 0.076 0.0456 0.0419 0.465 0.0754 0.0341 0.0392 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1215 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-008FS Proiect:

YANK01204 Sample ID:

176227010 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualffier Result Uncertainty LC TPU MI)A Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

9506-0000-009F Proiect:

YANK01204 Sample ID:

176227011 Client ID:

YANKOOI Matrix:

TS Vol. Recv.:

Collect Date:

09-NOV-06 Receive Date:

16-NOV-06 Collector:

Client Moisture:

19.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnrna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.850

+/-0.173 Americium-241 U

0.004

+/-0.0742 Bismuth-212 0.681

+/-0.317 Bismuth-214 0.550

+/-0.0952 Cesium-134 U

0.00462

+/-0.0226 Cesium-137 0.0637

+/-0.0428 Cobalt-60 U

-0.0145

+/-0.0208 Europium-152 U

0.00679

+/-0.0606 Europium-154 U 0.000678

+/-0.0626 Europium-155 U

0.0059

+/-0.0564 Lead-212 0.711

+/-0.0933 Lead-214 0.685

+/-0.0965 Manganese-54 U

0.0089

+/-0.0199 Niobium-94 U

0.0148

+/-0.0186 Potassium-40 10.3

+/-1.07 Radium-226 0.550

+/-0.0952 Silver-108m U

-0.019

+/-0.0207 Thallium-208 0.234

+/-0.0458 0.052 0.059 0.124 0.0306 0.0199 0.017 0.0158 0.0467 0.0527 0.0504 0.0381 0.0331 0.0179 0.0172 0.182 0.0306 0.0151 0.0171

+/-0.173

+/-0.0742

+/-0.317

+/-0.0952

+/-0.0226

+/-0.0428

+/-0.0208

+/-0.0606

+/-0.0626

+/-0.0564

+/-0.0933

+/-0.0965

+/-0.0199

+/-0.0186

+/-1.07

+/-0.0952

+/-0.0207

+/-0.0458 0.104 0.118 0.248 0.0613 0.0399 0.0339 0.0317 0.0934 0.105 0.101 0.0762 0.0662 0.0357 0.0343 0.365 0.0613 0.0301 0.0342 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 11/21/06 1230 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defimed as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22,2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-009F Proiect:

YANK01204 Sample ID:

176227011 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-01 OF 176227012 TS 09-NOV-06 16-NOV-06 Client 19%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GainmaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.810 Americium-241 U

-0.0285 Bismuth-212 UI 0.00 Bismuth-214 0.506 Cesium-134 UI 0.00 Cesium-137 0.0498 Cobalt-60 U -4.030E-Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium--40 Radium-226 Silver-108m Thallium-208 05 U -0.00589 U

-0.0365 U

0.00705 0.611 0.502 U

0.0108 U

0.00479 9.04 0.506 U

0.00885 0.217

+/-0.137

+/-0.127

+/-0.386

+/-0.0771

+/-0.0314

+/-0.0416

+/-0.0213

+/-0.0598

+/-0.0701

+/-0.0569

+/-0.0528

+/-0.0834

+/-0.0209

+/-0.0206

+/-0.751

+/-0.0771

+/-0.0185

+/-0.0391 0.0589 0.0748 0.132 0.0306 0.0194 0.0174 0.0151 0.0511 0.045 0.0522 0.0303 0.0341 0.0187 0.0155 0.169 0.0306 0.0162 0.0184

+/-0.137

+/-0.127

+/-0.386

+/-0.0771

+/-0.0314

+/-0.0416

+/-0.0213

+/-0.0598

+/-0.0701

+/-0.0569

+/-0.0528

+/-0.0834

+/-0.0209

+/-0.0206

+/-0.751

+/-0.0771

+/-0.0185

+/-0.0391 0.127 0.154 0.282 0.0652 0.0417 0.0371 0.034 0.107 0.100 0.108 0.0627 0.0715 0.0399 0.0332 0.375 0.0652 0.0341 0.0391 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1246 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-01 OF Proiect:

YANK01204 Sample ID:

176227012 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-01 IF 176227013 TS 09-NOV-06 16-NOV-06 Client 10.9%

Project:

YANK01204 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gaintna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-t34 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.38 U

0.0298 1.00 1.25 UI 0.00 U

-0.0211 U

-0.007 U

0.012 U

0.0335 U

0.0447 1.23 1.47 U

0.0262 U

0.0126 22.3 1.25 U

0.00973 0.374

+/-0.230

+/-0.0628

+/-0.303

+/-0.153

+/-0.028

+/-0.0184

+/-0.0223

+/-0.0495

+/-0.0633

+/-0.0574

+/-0.113

+/-0.161

+/-0.0311

+/-0.0185

+/-1.71

+/-0.153

+/-0.0173

+/-0.0577 0.0588 0.0578 0.128 0.0296 0.0235 0.0148 0.0159 0.0439 0.0573 0.0513 0.0252 0.0288 0.017 0.0169 0.140 0.0296 0.0153 0.0173

+/-0.230

+/-0.0628

+/-0.303

+/-0.153

+/-0.028

+/-0.0184

+/-0.0223

+/-0.0495

+/-0.0633

+/-0.0574

+/-0.113

+/-0.161

+/-0.0311

+/-0.0185

+/-1.71

+/-0.153

+/-0.0173

+/-0.0577 0.125 0.119 0.271 0.0625 0.0492 0.0315 0.0349 0.0915 0.123 0.105 0.052 0.0603 0.0361 0.0354 0.310 0.0625 0.032 0.0364 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1247 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-01IF Project:

YANK01204 Sample ID:

176227013 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. lack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-012F 176227014 TS 09-NOV-06 16-NOV-06 Client 14.6%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.896

+/-0.180 Americium-241 U

0.0447

+/-0.0825 Bismuth-212 0.725

+/-0.256 Bismuth-214 0.652

+/-0.113 Cesium-134 U1 0.00

+/-0.0304 Cesium-I 37 U

0.0253

+/-0.0306 Cobalt-60 U-0.000688

+/-0.0194 Europium-152 U

-0.0413

+/-0.080 Europium-154 U

0.00592

+/-0.0654 Europium-155 U

0.0232

+/-0.0577 Lead-212 0.803

+/-0.0872 Lead-214 0.732

+/-0.111 Manganese-54 U

0.0278

+/-0.0228 Niobium-94 U

0.00266

+/-0.0183 Potassium-40 10.3

+/-0.930 Radium-226 0.652

+/-0.113 Silver-108m U -0.00139

+/-0.0171 Thallium-208 0.238

+/-0.0426 0.0531 0.071 0.123 0.0312 0.0216 0.0153 0.0165 0.0473 0.0487 0.0544 0.0262 0.0346 0.0148 0.0158 0.124 0.0312 0.0153 0.0155

+/-0.180

+/-0.0825

+/-0.256

+/-0.113

+/-0.0304

+/-0.0306

+/-0.0194

+/-0.080

+/-0.0654

+/-0.0577

+/-0.0872

+/-0.111

+/-0.0228

+/-0.0183

+/-0.930

+/-0.113

+/-0.0171

+/-0.0426 0.106 0.142 0.247 0.0623 0.0432 0.0305 0.033 0.0945 0.0973 0.109 0.0524 0.0692 0.0295 0.0317 0.248 0.0623 0.0305 0.0309 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1313 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-012F Project:

YANK01204 Sample ID:

176227014 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte.was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-013F 176227015 TS 13-NOV-06 16-NOV-06 Client 24.1%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Amn241, Cm, Solid ALL FSS Americium-241 U

0.0447

+/-0.0836 0.0371 +/-0.0838 Curium-242 Curium.-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 Plutonium-239/240 Liquid Scint Pu241, Solid-ALL 1 Plutonium-241 U -0.00721

+/-0.0141 0.027 +/-0.0142 U

0.0304

+/-0.0856 0.0525 +/-0.0857 U

-0.0365

+/-0.106 0.106

+/-0.106 U

-0.0548

+/-0.0406 0.0775

+/-0.041 U

-1.68

+/-7.21 6.13

+/-7.21 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.528 Americium-241 U

0.00634 Bismuth-212 UI 0.00 Bismuth-214 0.277 Cesium-134 U

0.00491 Cesium-137 0.252 Cobalt-60 U 0.000673 Europium-152 U

0.00973 Europium-154 U

0.0148 Europium-155 U

0.0101 Lead-212 0.433

+/-0.182

+/-0.031

+/-0.454

+/-0.0916

+/-0.026

+/-0.0553

+/-0.0268

+/-0.0569

+/-0.088

+/-0.0541

+/-0.0781

+/-0.0944

+/-0.0231

+/-0.025

+/-1.20

+/-0.0916

+/-0.0185

+/-0.0564 0.0694 0.0295 0.156 0.0397 0.0234 0.0214 0.0226 0.0519 0.0759 0.0498 0.0292 0.0311 0.0195 0.0212 0.162 0.0397 0.0163 0.0191

+/-0.182

+/-0.031

+/-0.454

+/-0.0916

+/-0.026

+/-0.0553

+/-0.0268

+/-0.0569

+/-0.088

+/-0.0541

+/-0.0781

+/-0.0944

+/-0.0231

+/-0.025

+/-1.20

+/-0.0916

+/-0.0185

+/-0.0564 0.153 0.135 0.184 0.300 0.243 12.9 0.155 0.0613 0.342 0.086 0.0513 0.0466 0.0512 0.111 0.168 0.104 0.0615 0.0672 0.0431 0.0458 0.384 0.086 0.0354 0.0416 0.0181 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

/IXA I

11/21/06 1100 589570 3

MXA 11/19/06 0732 589568 1

1 MXA 11/19/060732 589569 2

1 MJH1 11/21/06 1310 589209 4

Lead-214 Manganese-54 U -

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U-C Thallium-208 Rad Gas Flow Proportional Counting 0.403 0.00791 0.00024 10.8 0.277 1.000112 0.164 GFPC, Sr90, solid - 0.025 pCi/g Strontium-90 Rad Liquid Scintillation Analysis U -0.00427

+/-0.00972 0.00845 +/-0.00972 KSD1 11/21/06 1537 589170 5

68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

9506-0000-013F 176227015 Project:

YANK01204 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCilg Tritium U

0.113 Liquid Scint C14, Solid All, FSS Carbon-14 U -0.0816 Liquid Scint Fe55, Solid-ALL FSS Iron-55

  • U

-13.2 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-4.2 Liquid Scinr Tc99, Solid-ALL FSS Technetium-99 0.644 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-1.10 0.917

+/-1.10 2.01 pCi/g

+/-0.110 0.0936

+/-0.110 0.191

+/-37.7 29.4

+/-37.7 61.8

+/-5.44 4.69

+/-5.44 9.67

+/-0.258 0.199

+/-0.259 0.411 pCi/g pCi/g pCi/g pCi/g DFAI 11/21/06 0949 589090 7 AXD2 11/16/06 1830 589089 9

MXP1 11/21/06 0030 589223 IC MXPI 11/20/06 2005 589224 11 KXR1 11/21/06 1309 589096 12 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-1-RC Modified 3

DOE EML HASL-300, Pu-11-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 905.0 Modified 7

EPA 906.0 Modified 8

EPA 906.0 Modified 9

EPA EERF C-01 Modified 10 DOE RESL Fe-1, Modified 11 DOE RESL Ni-i, Modified 12 DOE EML HASL-300, Tc-02-RC Modified 13 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS 98 88 (15%-125%)

(15%-125%)

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-013F Project:

YANK01204 Sample ID:

176227015 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Plutonium-241 Liquid Scint Pu241, Solid-ALL FE 85 (25%-125%)

Strontium-90 GFPC, Sr9O, solid - 0.025 pCi/g 69 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr9O, solid - 0.025 pCi/g 69 (25%-125%)

Iron-55 Liquid Scint Fe55, Solid-ALL FS 55 (15%-125%)

Nickel-63 Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)

Technetiumn-99 Liquid Scint Tc99, Solid-ALL FS 82 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 82 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-014F 176227016 TS 09-NOV-06 16-NOV-06 Client 18.6%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gaimna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.644

+/-0.141 Americium-241 U

0.0324

+/-0.093 Bismuth-212 0.296

+/-0.265 Bismuth-214 0.522

+/-0.0784 Cesium-134 U

0.0338

+/-0.0333 Cesium-137 0.044

+/-0.0233 Cobalt-60 U

-0.0139

+/-0.0212 Europium-152 U -0.00353

+/-0.0503 Europium-154 U 0.00397

+/-0.064 Europium-155 U

0.0881

+/-0.0841 Lead-212 0.703

+/-0.058 Lead-214 0.622

+/-0.0776 Manganese-54 U

0.00396

+/-0.0195 Niobium-94 U

0.00952

+/-0.0168 Potassium-40 11.5

+/-0.887 Radium-226 0.522

+/-0.0784 Silver-108m U

0.00318

+/-0.0154 Thallium-208 0.232

+/-0.0474 0.0614 0.085 0.117 0.0294 0.0213 0.0141 0.0165 0.0432 0.055 0.048 0.0251 0.0287 0.0168 0.0152 0.145 0.0294 0.0142 0.0155

+/-0.141

+/-0.093

+/-0.265

+/-0.0784

+/-0.0333

+/-0.0233

+/-0.0212

+/-0.0503

+/-0.064

+/-0.0841

+/-0.058

+/-0.0776

+/-0.0195

+/-0.0168

+/-0.887

+/-0.0784

+/-0.0154

+/-0.0474 0.132 0.176 0.252 0.0627 0.0452 0.0305 0.0367 0.0909 0.120 0.0995 0.0523 0.0606 0.0361 0.0324 0.327 0.0627 0.0301 0.033 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1340 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-014F Project:

YANK01204 Sample ID:

176227016 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-015F 176227017 TS 09-NOV-06 16-NOV-06 Client 15.4%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtý Rad Gamma Spec Analysis Gaintna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.545

+/-0.11.1 Americium-241 U

-0.0459

+/-0.089 Bismuth-212 0.597

+/-0.211 B3ismuth-214 0.294

+/-0.0574 Cesium-134 U

0.0195

+/-0.0164 Cesium-137 U

0.0202

+/-0.0297 Cobalt-60 U

-0.0036

+/-0.0146 Europium-152 U

-0.0332

+/-0.0368 Europium-154 U

0.00178

+/-0.0458 Europium-155 U

0.0256

+/-0.0426 Lead-212 0.458

+/-0.0412 Lead-214 0.277

+/-0.0625 Manganese-54 U

0.00265

+/-0.0159 Niobium-94 U

0.0071

+/-0.0127 Potassium-40 12.1

+/-0.648 Radium-226 0.294

+/-0.0574 Silver-108m U-0.000366

+/-0.0128 Thallium-208 0.158

+/-0.0305 0.0403 0.069 0.0815 0.0191 0.0145 0.0131 0.0123 0.0316 0.0399 0.0406 0.0197 0.0237 0.0122 0.0116 0.106 0.0191 0.0112 0.0111

+/-0.111

+/-0.089

+/-0.211

+/-0.0574

+/-0.0164

+/-0.0297

+/-0.0146

+/-0.0368

+/-0.0458

+/-0.0426

+/-0.0412

+/-0.0625

+/-0.0159

+/-0.0127

+/-0.648

+/-0.0574

+/-0.0128

+/-0.0305 0.0865 0.143 0.175 0.0408 0.0307 0.0277 0.0268 0.0663 0.0857 0.0842 0.041 0.0496 0.026 0.0246 0.233 0.0408 0.0236 0.0236 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 11/21/06 1341 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defimed as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-015F Proiect:

YANK01204 Sample ID:

176227017 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MLDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-016F 176227018 TS 09-NOV-06 16-NOV-06 Client 28.2%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS CAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.496

+/-0.102 Americium-241 U

-0.0788

+/-0.060 Bismuth-212 0.383

+/-0.185 Bismuth-214 Ul 0.00

+/-0.0603 Cesium-134 U

0.0196

+/-0.0165 Cesium-137 0.190

+/-0.0296 Cobalt-60 U

0.00815

+/-0.0155 Europium-152 U

-0.0168

+/-0.0374 Europium-154 U

0.0442

+/-0.0467 Europium-155 U

0.0521

+/-0.0709 Lead-212 0.476

+/-0.0405 Lead-214 0.361

+/-0.055 Manganese-54 U

-0.0121

+/-0.0147 Niobium-94 U -0.00146

+/-0.015 Potassium-40 11.1

+/-0.600 Radium-226 0.339

+/-0.0603 Silver-108m U

0.00264

+/-0.0127 Thallium-208 0.141

+/-0.027 0.0426 0.048 0.0942 0.0485 0.0155 0.0122 0.0139 0.0318 0.0387 0.0373 0.0187 0.023 0.0121 0.0109 0.110 0.0255 0.0115 0.0116

+/-0.102

+/-0.060

+/-0.185

+/-0.0603

+/-0.0165

+/-0.0296

+/-0.0155

+/-0.0374

+/-0.0467

+/-0.0709

+/-0.0405

+/-0.055

+/-0.0147

+/-0.015

+/-0.600

+/-0.0603

+/-0.0127

+/-0.027 0.0908 0.099 0.199 0.0993 0.0326 0.0258 0.0299 0.0664 0.0829 0.077 0.0387 0.0481 0.0257 0.0231 0.241 0.0534 0.0241 0.0245 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/21/06 1342 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-016F Project:

YANK01204 Sample ID:

176227018 Client ID:

YANKO0I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: November 22, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-017F 176227019 TS 10-NOV-06 16-NOV-06 Client 9.55%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.467

+/-0.0907 Americium-241 U

0.0173

+/-0.0341 Bismuth-212 0.348

+/-0.111 Bismuth-214 0.376

+/-0.0497 Cesium-134 UI 0.00

+/-0.0112 Cesium-137 0.0391

+/-0.0141 Cobalt-60 U

0.0107

+/-0.00953 Europium-152 U -0.00383

+/-0.0272 Europium-154 U

-0.0141

+/-0.0286 Europium-155 U

0.0395

+/-0.0318 Lead-212 0.426

+/-0.0414 Lead-214 0.450

+/-0.0526 Manganese-54 U

0.00903

+/-0.0098 Niobium-94 U

0.00515

+/-0.00873 Potassium-40 8.83

+/-0.645 Radium-226 0.376

+/-0.0497 Silver-108m U -0.00338

+/-0.00814 Thallium-208 0.136

+/-0.0209 0.0254 +/-0.0907 0.0292 +/-0.0341 0.0635

+/-0.111 0.0148 +/-0.0497 0.00987 +/-0.0112 0.00927 +/-0.0141 0.00885 +/-0.00953 0.0216 +/-0.0272 0.024 +/-0.0286 0.0249 +/-0.0318 0.0127 +/-0.0414 0.0162 +/-0.0526 0.00788 +/-0.0098 0.00781 +/-0.00873 0.0655

+/-0.645 0.0148 +/-0.0497 0.00725 +/-0.00814 0.00871 +/-0.0209 0.0534 0.0594 0.132 0.0308 0.0205 0.0192 0.0187 0.0444 0.0506 0,0506 0.026 0.0332 0.0164 0.0162 0.141 0.0308 0.015 0.018 pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 11/21/06 1651 589209 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 11/16/06 1050 589083 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: November 22, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-017F Proiect:

YANK01204 Sample ID:

176227019 Client ID:

YANKO0I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

78

QUALITY CONTROL DATA 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: November 22,2006 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

176227 Parmname NOM Sample Qual QC Units RPD %

REC%

Range AnIst Date Time Rad Alpha Spec Batch 589568 QC 1201231905 Americium-241 Curium-242 Curium-243/244 QC1201231907 Americium-241 Curium-242 Curium-243/244 QC 1201231904 Americium-241 176227005 DUP U

0.0532 Uncert:

+/-0.0844 TPU:

+/-0.0847 U

0.00 Uncert:

+/-0.0611 TPU:

+/-0.0611 U

-0.00717 Uncert:

+/-0.0141 TPU:

+/-0.0141 LCS MB 13.3 Uncert:

TPU:

Uncert:

TPU:

15.9 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0291

+/-0.0578

+/-0.058 U

0.00

+/-0.0604

+/-0.0604 U

-0.0142

+/-0.0196

+/-0.0197 13.3

+/-1.25

+/-2.19 U

0.00

+/-0.0607

+/-0.0607 16.3

+/-1.39

+/-2.60 U

0.115

+/-0.120

+/-0.121 U

-0.0146

+/-0.0203

+/-0.0204 U

0.00

+/-0.0592

+/-0.0592 pCi/g 683 pCi/g 0

pCi/g 66 (0% - 100%) AIXA1 (0%- 100%)

(0%- 100%)

Curium-242 pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g 103 (75%-125%)

11/19/06 07:32 100 (75%-125%)

Curium-243/244 QC1201231906 Americium-241 176227005 MS Curium-242 13.7 Uncert:

TPU:

Uncert:

TPU:

16.5 Uncert:

TPU:

U 0.0532

+/-0.0844

+/-0.0847 U

0.00

+/-0.0611

+/-0.0611 U

-0.00717

+/-0.0141

+/-0.0141 U

15.5

+/-1.33

+/-2.45 0.031

+/-0.0608

+/-0.0609 17.6

+/-1.42

+/-2.74 113 (75%-125%)

Curium-243/244 107 (75%-125%)

Batch 589569 QC1201231909 176227005 DUP Plutonium-238 U

0.0186 U

-0.0542 pCilg 409 (0% - 100%) AXA1 11/19/06 07:32 80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 589569 Plutonium-239/240 QC1201231911 LCS Plutonium-238 Plutonium-239/240 QC1201231908 MB Plutonium-238 Plutonium-239/240 QC1201231910 176227005 MS Plutonium-238 Plutonium-239/240 Uncert:

+/-0.0741 TPU:

+/-0.0741 U

-0.0243 Uncert:

+/-0.0831 TPU:

+/-0.0831 Uncert:

TPU:

12.3 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.0186 Uncert:

+/-0.0741 TPU:

+/-0.0741 12.7 U

-0.0243 Uncert:

+/-0.0831 TPU:

+/-0.0831

+/-0.120

+/-0.120 U

-0.0867

+/-0.0491

+/-0.0498 U

0.143

+/-0.175

+/-0.175 11.4

+/-1.24

+/-1.74 U

-0.015

+/-0.0208

+/-0.0208 U

0.0712

+/-0.109

+/-0.109 pCi/g 112 pCi/g pCi/g (0%- 100%)

(75%-125%)

93 (75%-125%)

pCi/g pCi/g pCi/g PCi/g U

0.0749

+/-0.148

+/-0.148 12.8

+/-1.26

+/-1.82 (75%-125%)

101 (75%-125%)

Batch 589570 QC1201231913 176227005 DUP Plutonium-241 QC1201231915 LCS Plutonium-241 Uncert:

TPU:

U

-0.362

+/-6.41

+/-6.41 U

3.85

+/-7.21

+/-7.22 pCi/g 0

(0% - 100%) VAXA1 QC1201231912 MB Plutonium-241 143 Uncert:

TPU:

Uncert:

TPU:

143 U

Uncert:

TPU:

124

+/-12.5

+/-17.9 U

-1.89

+/-7.16

+/-7.16 pCi/g PCi/g pCi/g 87 (75%-125%)

11/21/06 11:32 11/21/06 12:04 11/21/06 11:16 11/21/06 11:48 QC1201231914 176227005 MS Plutonium-241 Rad Gamma Spec Batch 589209 QC1201231040 176227001 DUP Actinium-228

-0.362

+/-6.41

+/-6.41 129

+/-11.6

+/-17.3 90 (75%-125%)

0.525

+/-0.210 Uncert:

0.561

+/-0.148

+/-0.148 pCi/g 7

(0% - 100%) MJHI 11/21/06 16:52 81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 589209 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.210 u

0.0255 U

-0.00697 Uncert:

+/-0.105

+/-0.0211 TPU:

+/-0.105

+/-0.0211 0.496 0.628 Uncert:

+/-0.274

+/-0.279 TPU:

+/-0.274

+/-0.279 0.329 0.367 Uncert:

+/-0.0712

+/-0.0691 TPU:

+/-0.0712

+/-0.0691 u

0.0173 UI 0.00 Uncert:

+/-0.0243

+/-0.0375 TPU:

+/-0.0243

+/-0.0375 0.182 0.175 Uncert:

+/-0.0473

+/-0.0288 TPU:

+/-0.0473

+/-0.0288 U

0.000215 U

0.00436 Uncert:

+/-0.0196

+/-0.0179 TPU:

+/-0.0196

+/-0.0179 U

0.0228 U

0.0173 Uncert:

+/-0.0508

+/-0.0403 TPU:

+/-0.0508

+/-0.0403 U

0.0472 U

-0.0264 Uncert:

+/-0.0668

+/-0.0516 TPU:

+/-0.0668

+/-0.0516 U

0.0144 U

-0.0105 Uncert:

+/-0.0535

+/-0.0349 TPU:

+/-0.0535

+/-0.0349 0.531 0.505 Uncert:

+/-0.0594

+/-0.0459 TPU:

+/-0.0594

+/-0.0459 0.396 0.402 Uncert:

+/-0.0891

+/-0.0648 TPU:

+/-0.0891

+/-0.0648 U

0.0046 U

0.0146 Uncert:

+/-0.0213

+/-0.0175 TPU:

+/-0.0213

+/-0.0175 U

8.600E-05 U

0.00643 Uncert:

+/-0.0187

+/-0.0154 TPU:

+/-0.0187

+/-0.0154 10.9 10.6 Uncert:

+/-0.895

+/-0.634 TPU:

+/-0.895

+/-0.634 0.329 0.367 Uncert:

+/-0.0712

+/-0.0691 TPU:

+/-0.0712

+/-0.0691 U

-0.0144 U

-0.00132 Uncert:

+/-0.0165

+/-0.0131 pCi/g 351 pCi/g 23 pCi/g II pCi/g 84 pCi/g 4

pCi/g 181 pC/g 28 pCi/g 707 pCilg 1250 pClg 5

pCi/g I

pCi/g 104 pCi/g 195 pCi/g 3

pCi/g 11 pCi/g 166 (0% - 100%)

(0% - 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 20%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 20%)

(0%- 100%)

(0%- 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 589209 Thallium-208 TPU:

+/-0.0165 0.164 Uncert:

+/-0.0416 TPU:

+/-0.0416

+/-0.0131 0.169

+/-0.0345

+/-0.0345 pCi/g 3

(0%- 100%)

.QC1201231041 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 LCS Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.53 Uncert:

TPU:

14.1 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.0925

+/-0.558

+/-0.558 25.0

+/-1.47

+/-1.47 U

0.905

+1-0.898

+/-0.898 U

-0.0608

+/-0.208

+/-0.208 U

0.152

+/-0.182

+/-0.182 9.64

+/-0.468

+/-0.468 15.2

+/-0.655

+/-0.655 U

-0.378

+/-0.270

+/,0.270 U

0.184

+/-0.271

+/-0.271 U

0.106

+/-0.262

+/-0.262 U

-0.0422

+/-0.146

+/-0.146 U

0.0574

+/-0.201

+/-0.201 U

0.000745

+/-0.147

+/-0.147 U

0.00757

+/-0.108

+/-0.108 U

0.202 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 11/22/06 05:55 107 (75%-125%)

101 (75%-125%)

108 (75%-125%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 589209 Radium-226 Silver-108m Thallium-208 QC1201231039 MB Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-1.13

+/-1.13 U

-0.0608 pCi/g

+/-0.208

+/-0.208 U

0.0127 pCi/g

+/-0.101

+/-0.101 U

0.0344 pCi/g

+/-0.107

+/-0.107 UI 0.00 pCi/g

+/-0.0444

+/-0.0444 U

0.0088 pCi/g

+/-0.0249

+/-0.0249 U

0.0393 pCi/g

+/-0.0516

+/-0.0516 U

0.0131 pCi/g

+/-0.0143

+/-0.0143 U

0.00793 pCi/g

+/-0.00644

+/-0.00644 U

0.00227 pCilg

+/-0.0094

+/-0.0094 U

0.00133 pCi/g

+/-0.0067

+/-0.0067 U

0.0139 pCilg

+/-0.0187

+/-0.0187 U

0.0021 pCi/g

+/-0.0189

+/-0.0189 U

0.0205 pCi/g

+/-0.0337

+/-0.0337 U

0.0164 pCi/g

+/-0.011

+/-0.011 U

0.0113 pCilg

+/-0.0134

+/-0.0134 11/21/06 16:51 (75%-125%)

Lead-212 Lead-214 84

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 589209 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.00534

+/-0.00617

+/-0.00617 U

-0.0015

+/-0.00599

+/-0.00599 Ul 0.00

+/-0.103

+/-0.103 U

0.0131

+/-0.0143

+/-0.0143 U

0.000137

+/-0.00602

+/-0.00602 U

0.00592

+/-0.0124

+/-0.0124 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 589170 QC1201230917 176227005 DUP Strontium-90 QC1201230919 LCS Strontium-90 QC1201230916 MB Strontium-90 QC1201230918 176227005 MS Strontium-90 Rad Liquid Scintillation Batch 589089 QC1201230742 176227005 DUP Carbon-14 QC1201230744 LCS Carbon-14 QC1201230741 MB Carbon-14 U

-0.0138 Uncert:

+/-0.00986 TPU:

+/-0.00986 1.13 Uncert:

TPU:

Uncert:

TPU:

4.34 U

Uncert:

TPU:

-0.0138

+/-0.00986

+/-0.00986 U

-0.00325

+/-0.00844

+/-0.00844 1.14

+/-0.122

+/-0.128 U

-0.0089

+/-0.0081

+/-0.0081 4.12

+/-0.479

+/-0.488 U

-0.00212

+/-0.114

+/-0.114 6.62

+/-0.205

+/-0.230 pCilg PCilg PCilg 101 (75%-125%)

95 (75%-125%)

pCi/g 0

(0% - 100%) KSD1 11/20/06 21:36 11/20/06 13:05 11/20/06 20:47 11/20/06 13:05 U

-0.117 Uncert:

+/-0.114 TPU:

+/-0.114 6.81 Uncert:

TPU:

pCi/g 0

(0% - 100%) AXD2 pCi/g 97 (75%-125%)

11/16/06 20:35 11/16/06 22:40 11/16/06 19:32 U

-0.0935 pCi/g 85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD %

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 589089 Uncert:

TPU:

QC1201230743 176227005 MS Carbon-14 6.91 U

Uncert:

TPU:

-0.117

+/-0.114

+/-0.114

+/-0.110

+/-0.110 6.80

+/-0.209

+/-0.234 pCi/g 98 (75%-125%)

11/16/06 21:37 Batch 589090 QC1201230746 176227005 DUP Tritium QC1201230748 LCS Tritium U

1.09 Uncert:

+/-1.24 TPU:

+/-1.24 U

1.25

+/-1.30

+/-1.30 pCi/g 0

(0% - 100%) DFA1 QC1201230745 Tritium MB 10.6 Uncert:

TPU:

Uncert:

TPU:

10.9 U

Uncert:

TPU:

9.83

+/-1.87

+/-1.88 U

1.04

+/-1.19

+/-1.19 pCi/g pCilg pCilg 92 (75%-125%)

11/21/06 10:22 11/21/06 10:55 11/21/06 10:06 11/21/06 10:38 QC1201230747 176227005 MS Tritium 1.09

+/-1.24

+/-1.24 Batch 589096 QC1201230759 176227005 DUP Technetium-99 QC1201230761 LCS Technetium-99 QC1201230758 MB Technetium-99 QC1201230760 176227005 MS Technetium-99 0.599 Uncert:

+/-0.253 TPU:

+/-0.253 8.26

+/-1.78

+/-1.79 0.437

+/-0.228

+/-0.228 12.8

+/-0.482

+/-0.563 76 (75%-125%)

pCi/g 31 (0% - 100%) KXR1 12.7 Uncert:

TPU:

Uncert:

TPU:

12.6 Uncert:

TPU:

U 0.0526

+/-0.197

+/-0.197 pCilg pCilg 101 (75%-125%)

11/21/06 13:41 11/21/06 14:14 11/21/06 13:25 11/21/06 13:58 0.599

+/-0.253

+/-0.253 11.6

+/-0.493

+/-0.559 87 (75%-125%)

Batch 589223 QC1201231092 176227005 DUP Iron-55 U

6.46 Uncert:

+/-33.1 TPU:

+/-33.1 U

-1.65

+/-37.7

+/-37.7 pCi/g 0

(0% - 100%) \\4XP1 11/21/06 01:02 11/21/06 01:35 QC1201231094 LCS Iron-55 625 Uncert:

TPU:

620

+/-51.9

+/-78.0 pCi/g 99 (75%-125%)

86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Liquid Scintillation Batch 589223 QC1201231091 MB Iron-55 QC1201231093 176227005 MS Iron-55 Uncert:

TPU:

644 U

Uncert:

TPU:

U

-17.1

+/-30.2

+/-30.2 pCi/g pCi/g 11/21/06 00:46 11/21/06 01:19 6.46

+/-33.1

+/-33.1 668

+/-58.9

+/-91.6 104 (75%-125%)

Batch 589224 QC1201231096 176227005 DUP Nickel-63 QC1201231098 LCS Nickel-63 U

-0.892 Uncert:

+/-4.43 TPU:

+/-4.43 U

1.23

+/-4.99

+/-4.99 pCi/g 0

(0% - 100%) \\4XPI QC1201231095 MB Nickel-63 511 Uncert:

TPU:

Uncert:

TPU:

566 U

Uncert:

TPU:

456

+/-12.4

+/-20.0 U

-1.52

+/-4.17

+/-4.17 pCi/g pCi/g pCi/g 89 (75%-125%)

11/20/06 21:38 11/20/06 23:11 11/20/06 20:51 11/20/06 22:24 QC1201231097 176227005 MS Nickel-63

-0.892

+/-4.43

+/-4.43 520

+/-13.9

+/-23.3 92 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +l-RL. Concentrations are <5X the RL 87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

176227 Pa,,* Q r' Q

P-e 9 of 0 F,

Parnmname NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time A

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

88

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 178968 SDG: MSR#07-0037 January 15, 2007 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on January 12, 2007 for analysis.

Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 178968001 9506-0000-018F 178968002 9506-0000-019F 178968003 9506-0000-020F Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Two soil samples were analyzed for FSSGAM. One soil sample was analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cher Jones Project Manager GEL Laboratories Lic P0 Box30712 Charleston, SC 29417 2040 Savage Road Charleston,SC 29407 P843.556.8171 F 843.766.1178 2

www.gel.com

List of current GEL Certifications as of 15 January 2007 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FIJNELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC 12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota-R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 3

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2007-00015 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type

- eneral Engineering Laboratories Code

,z040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: E] 30 D. L 15 D. Z 7 D.

O ther:

ý Sample Desination Date Time Comment, Preservation Lab Sample ID 9506-0000-018F 01-11-07 0 C1 -0 TS G

BP X

9506-0000-019F 01-11-07 0()<,

TS G

BP X

9506-0000-020F 01-11-07 L-) d"70 TS G

BP X

NOTES: PO #: 002332 MSR #: C7 7

Z LTP QA ED Radwaste QA Ij Non QA Samples Shipped Via:

Interal C8ntainer S Fed Ex Temp.: _Le Deg. C M UPS E Hand Custody Sealed?

1)Date/Time

2)

Iate/Time Custody Seal Intact?

3YRelinquished By Date/Time

4) Received By Date/Time 974/ 0 77? 2,*,/'/

Y [-

N E 5

RBill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

.Connecticut Yankee Cy-ISC-SOW-001 Statement of Work for Analytical Lab Services

..I-C

.O-Figure 1. -Sample Check-in List Date/Time Received:*

SDG#:-

-Work Order Number:

1 shipping Cd.-tainer D.ChainofCustody#

~Ye

  • No[_
1.

Custody Seals odi shipping container intact?:..

Ye N.

2.

Custody Seals dated and signed?

..Yes o[]

3.

Chain-of-Custody record present?

Yes No""

.4.

Cooler temperature

5.

Vermiculite/packing materials is:

Wet[I Dry..

" 6- *Number of samples in shipping container:

3

7.

Sample holding times exceeded?

Yes [ ] No

-8. Samples have:

.. 4

_tape hazard labels custody seals appropriate sample labels

9. Samples ar-'"

""-in good condition leaking broken

_have air bubbles 10.

11.

Were any anomalies identified in sample receipt?

.Description of anomalies.(include sample numbers):

yes[

No,~

I I

$ample Custodian/Labpratory:

Telephoned to:

C' 'i~r1I1L~D n~ta*

I 11210'1 Date:

On By_

Data Review Qualifier Definitions 7

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound c

Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is >10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit U1 Gamma Spectroscopy-Uncertain identification K

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no-free liquids were observed.

GEL Laboratories LLc PO EU 30712 Charleston SC 29417 2040 Savage Road Chatrleston, SC 29407 P 843.555.171 F 843.766.1178 www.gol.com 8

RADIOLOGICAL ANALYSIS 9

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 178968 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 602063 602056 602055 Sample I1D 178968002 1201260615 1201260616 1201260617 1201260618 Client ID 9506-0000-019F Method Blank (MB) 178968002(9506-0000-019F) Sample Duplicate (DUP) 178968002(9506-0000-019F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

10

Ouality Control (0C) Information:

Blank Information.

The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178968002 (9506-0000-019F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to documentany procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 11

Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-lI -RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 602064 602056 602055 Sample ID 178968002 1201260619 1201260620 1201260621 1201260622 Client ID 9506-0000-019F Method Blank (MB) 178968002(9506-0000-019F) Sample Duplicate (DUP) 178968002(9506-0000-019F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178968002 (9506-0000-019F).

QC Information All of the QC samples met the required acceptance limits.

12

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-11-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 602065 602056 602055 13

Sample ID Client ID 178968002 9506-0000-019F 1201260623 Method Blank (MB) 1201260624 178968002(9506-0000-019F) Sample Duplicate (DUP) 1201260625 178968002(9506-0000-019F) Matrix Spike (MS) 1201260626 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178968002 (9506-0000-019F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this 14

SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

  • Prep Batch Number:

Sample ID 178968001 178968002 178968003 1201260866 1201260867 1201260868 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 602159 602055 Client ID 9506-0000-018F 9506-0000-019F 9506-0000-020F Method Blank (MB) 178923021(9539-0002-020-I) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

15

Quality Control (QC' Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178923021 (9539-0002-020-I).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample Ul Data rejected due to low abundance.

Americium-241 Bismuth-214 Cesium-134 178968002 1201260866 178968002 178968003 1201260867 1201260866 1201260866 1201260866 Lead-212 Potassium-40 Radium-226 16

Method/Analysis Information Product:

GFPC, Sr90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 603226 602056 602055 Sample ID 178968002 1201263218 1201263219 1201263220 1201263221 Client ID 9506-0000-019F Method Blank (MB) 178968002(9506-0000-019F) Sample Duplicate (DUP) 178968002(9506-0000-019F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178968002 (9506-0000-019F).

17

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 178968002 (9506-0000-019F) was reprepped due to high blank activity.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Sample 178968002 (9506-0000-019F) was verified using the first prep.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

Analytical Batch Number:

Sample ID 178968002 1201260283 1201260284 1201260285 1201260286 DOE EML HASL-300, Tc-02-RC Modified 601908 Client ID 9506-0000-019F Method Blank (MB) 178924001(9539-0001-001-F) Sample Duplicate (DUP) 178924001(9539-0001-001-F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 18

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 400520 was generated due to Container scanning event for custody missed. 1. The analyst did not scan sample 178968002 into the batch prior to analysis, however the sample did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper scanning procedures. 1. Reporting results.

Additional Comments Additional comments were not required for this sample set.

19

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALLFSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 602972 602056 602055 Sample ED 178968002 1201262579 1201262580 1201262581 1201262582 Client ID 9506-0000-019F Method Blank (MB) 178924001(9539-0001-001-F) Sample Duplicate (DUP) 17892400i(9539-0001-001-F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

20

Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery. Samples were reprepped due to low/high carrier/tracer yield. Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

602983 Prep Batch Number:

602056 Dry Soil Prep GL-RAD-A-021 Batch Number:

602055 21

Sample ED Client ID 178968002 9506-0000-019F 1201262609 Method Blank (MB) 1201262610 178968002(9506-0000-019F) Sample Duplicate (DUP) 1201262611 178968002(9506-0000-019F) Matrix Spike (MS) 1201262612 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178968002 (9506-0000-019F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this 22

SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method:

Analytical Batch Number:

Sample ID 178968002 1201260287 1201260288 1201260289 1201260290 EPA 906.0 Modified 601909 Client UD 9506-0000-019F Method Blank (MB) 178923010(9539-0002-009-F) Sample Duplicate (DUP) 178923010(9539-0002-009-F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178923010 (9539-0002-009-F).

23

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201260290 (LCS) was recounted due to analyst transcription error.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AII,FSS Analytical Method:

Analytical Batch Number:

Sample ID 178968002 1201260291 1201260292 1201260293 1201260294 EPA EERF C-01 Modified 601910 Client ID 9506-0000-019F Method Blank (MB) 178924001(9539-0001-001-F) Sample Duplicate (DUP) 178924001(9539-0001-00 1-F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in 24

accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 178924001 (9539-0001-001-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201260293 (9539-0001-001-F) was recounted due to spectral interference.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement 25

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

V fi 19 26

GEL Laboratories LLC Form GEL-NCR Rev. 06/05 NCR Report No.: 400520 Revision No.-

COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

17-JAN-07 Radiochemistry Specifications Process Instrument Type:

Test / Method:

Matrix Type:

Client Code:

LSC DOE EML HASL-300, Tc-02-RC Solid YANK

-Mdified Batch ID:

Sample Numbers:

601908 See Below Potentially affected work order(s)(SDG): 178923(MSR#07-0036),178924(MSR#07-0035),178968(MSR#07-0037)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan sample 178968002 into the batch prior to
1. Reporting results.

analysis, however the sample did remain in their custody at all times.

The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Originator's Name:

Layota Yom Quality Review:

Data Validator/Group Leader:

Lesley Anderson 19-JAN-07 17-JAN-07 Director:

Page 1 27

SAMPLE DATA

SUMMARY

28

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#07-0037 GEL Work Order: 178968 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 29

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: January 19, 2007 Client Sample ID:

9506-0000-018F Project:

YANK01204 Sample ID:

178968001 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

11-JAN-07 Receive Date:

12-JAN-07 Collector:

Client Moisture:

24.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.583

+/-0.104 Americium-241 U

0.0146

+/-0.0486 Bismuth-212 0.249

+/-0.136 Bismuth-214 0.409

+/-0.0583 Cesium-134 U

0.0223

+/-0.0147 Cesium-137 0.176

+/-0.0242 Cobalt-60 U

0.00384

+/-0.0125 Europium-152 U

-0.0204

+/-0.0387 Europium-154 U

0.00972

+/-0.039 Europium-155 U

0.00881

+/-0.0354 Lead-212 0.451

+/-0.0493 Lead-214 0.444

+/-0.0593 Manganese-54 U

0.00218

+/-0.0133 Niobium-94 U -0.00222

+/-0.0114 Potassium-40 10.3

+/-0.786 Radium-226 0.409

+/-0.0583 Silver-108m U -0.00131

+/-0.011 Thallium-208 0.175

+/-0.0283 0.0349 0.0391 0.074 0.0165 0.0112 0.0111 0.0108 0.0249 0.0335 0.0291 0.0155 0.0193 0.0101 0.00951 0.0921 0.0165 0.00927 0.00978

+1-0.104

+/-0.0486

+/-0.136

+/-0.0583

+/-0.0147

+/-0.0242

+/-0.0125

+/-0.0387

+/-0.039

+/-0.0354

+/-0.0493

+/-0.0593

+/-0.0133

+/-0.0114

+/-0.786

+/-0.0583

+/-0.011

+/-0.0283 0.0698 0.0782 0.148 0.033 0.0225 0.0221 0.0216 0.0499 0.0669 0.0581 0.0311 0.0386 0.0202 0.019 0.184 0.033 0.0185 0.0195 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 01/15/07 1725 602159 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/12/07 1141 602055 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria 30

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-018F Project:

YANK01204 Sample ID:

178968001 Client ID:

YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

    • Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

31

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: January 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-019F 178968002 TS 1 1-JAN-07 12-JAN-07 Client 20.9%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS

.Americium-241 U

-0.06

+/-0.0683 Curium-242 Curium-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 Plutonium-239/240 Liquid Scint Pu241, Solid-ALL 1 Plutonium-241 U

0.0244

+/-0.0648 U

-0.0503

+i-0.104 U

-0.0649

+/-0.0519 0.0564 +/-0.0683 0.0288 +/-0.0649 0.109

+/-0.104 0.099 +/-0.0524 0.198 0.145 0.304 0.320 0.465 19.4 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g U

-0.104

+/-0.154 0.171

+/-0.154

'SS U

-2.76

+/-11.0 9.34

+/-11.0 MXA 01/16/07 0835 602063 1

MXA 01/15/07 2224 602064 2

1 MXA 01/16/07 2331 602065 3

1 MJH1 01/15/07 1726 602159 4

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Waived Actinium-228 226 Ingrowth Americium-241 UI Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 U

Europium-152 U

Europium-154 U

Europium-155 U

Lead-212 Lead-214 Manganese-54 U

Niobium-94 U

Potassium-40 Radium-226 Silver-108m U

Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 Rad Liquid Scintillation Analysis 0.762 0.00 0.393 0.529 0.00 0.0612 0.00383

-0.0316

-0.0628 0.044 0.818 0.617 0.0119 0.00793 11.8 0.529 0.00402 0.264 4

4

+

4, 4E

+/-0.154 0.0555

+/-0.154

/-0.0292 0.020 +/-0.0292

+/-0.212 0.124

+/-0.212 1/-0.0871 0.0261 +/-0.0871

/-0.0265 0.0191 +/-0.0265

/-0.0276 0.0157 +/-0.0276 4/-0.0193 0.0163 +/-0.0193 1-0.0619 0.035 +/-0.0619

  • /-0.0631 0.0435 +/-0.0631
  • /-0.0503 0.0319 +/-0.0503

+/-0.0826 0.0188 +/-0.0826

/-0.0846 0.0251 +/-0.0846 4/-0.0182 0.0162 +/-0.0182 4/-0.0165 0.0146 +/-0.0165

+/-0.759 0.132

+/-0.759 4/-0.0871 0.0261 +/-0.0871

+/-0.015 0.013

+/-0.015 4/-0.0436 0.0145 +/-0.0436 0.111 0.0401 0.248 0.0522 0.0383 0.0314 0.0326 0.0699 0.087 0.0639 0.0376 0.0502 0.0323 0.0293 0.263 0.0522 0.026 0.0289 0.0483 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

P29I, C.

5;6-1 ayr pF /

pCi/g pCi/g KSDI 01/19/07 0925 603226 0.056

+/-0.0311 0.0224 +/-0.0312 32 5

~//e Ce

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: January 19, 2007 Client Sample ID:

Sample ID:

9506-0000-019F 178968002 Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U

1.11 Liquid Scint C14, Solid AllFSS Carbon-1 4 U

-0.0662 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-21.9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-10.2 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.175 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-1.37 1.08

+/-1.37

+/-0.117 0.0991

+/-0.117

+/-26.9 20.3

+/-26.9

+/-11.1 9.75

+/-11.1 2.31 0.202 pCilg pCi/g 43.1 pCi/g MXP1 01/15/07 1603 601909 8

MXP1 01/15/07 1844 601910 9 MXPI 01/18/07 0852 602972 10 MXP1 01/18/07 0815 602983 12 MXP1 01/17/07 1344 601908 14 20.4 pCi/g pCi/g

+/-0.172 0.142

+/-0. 1,

0.288 C.0 r /uye The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 01/12/07 1141 602055 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11-RC Modified 3

DOE EML HASL-300, Pu-I -RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 905.0 Modified 7

EPA 905.0 Modified 8

EPA 906.0 Modified 9

EPA EERF C-01 Modified 10 DOE RESL Fe-1, Modified 11 DOE RESL Fe-1, Modified 12 DOE RESL Ni-1, Modified 13 DOE RESL Ni-1, Modified 14 DOE EML HASL-300, Tc-02-RC Modified 15 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 33

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: January 19, 2007 Client Sample ID:

Sample ID:

9506-0000-019F 178968002 Project:

YANK01204 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Unceriainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Carrier/Tracer Recovery Carrier/Tracer Recovery Plutonium-242 Plutonium-241 Carrier/Tracer Recovery Strontium-90 Carrier/Tracer Recovery Carrier/Tracer Recovery Nickel-63 Carrier/Tracer Recovery Technetium-99 Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Pu241, Solid-ALL FE GFPC, Sr90, solid-ALL FSS GFPC, Sr90, solid-ALL FSS GFPC, Sr90, solid-ALL FSS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 84 84 63 35 35 87 87 87 66 66 80 80 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(25%-125%)

(25%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows :

A quality control analyte recovery is outside of specified acceptance criteria

    • Analyte is a surrogate compound Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: January 19, 2007 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9506-0000-020F 178968003 TS 11-JAN-07 12-JAN-07 Client 12.2%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.766

+/-0.129 Americium-241 U

-0.0225

+/-0.0505 Bismuth-212 0.399

+/-0.144 Bismuth-214 0.477

+/-0.0622 Cesium-134 UI 0.00

+/-0.0189 Cesium-137 0.131

+/-0.0274 Cobalt-60 U

0.00787

+/-0.0113 Europium-152 U

-0.024

+/-0.0264 Europium-154 U -0.00404

+/-0.0348 Europium-155 U

0.0207

+/-0.0381 Lead-212 0.695

+/-0.0625 Lead-214 0.535

+/-0.0705 Manganese-54 U -0.00176

+/-0.0104 Niobium-94 U

0.00918

+/-0.00985 Potassium-40 11.1

+/-0.894 Radium-226 0.477

+/-0.0622 Silver-108m U

-0.0036

+/-0.00925 Thallium-208 0.229

+/-0.0345 0.0321

+/-0.129 0.0428 +/-0.0505 0.0679

+/-0.144 0.0167 +/-0.0622 0.0119 +/-0.0189 0.00907 +/-0.0274 0.00998 +/-0.0113 0.0231 +/-0.0264 0.0292 +/-0.0348 0.0274 +/-0.0381 0.0139 +/-0.0625 0.0167 +/-0.0705 0.00907 +/-0.0104 0.00874 +/-0.00985 0.0818

+/-0.894 0.0167 +/-0.0622 0.0081 +/-0.00925 0.00831 +/-0.0345 0.0673 0.0872 0.142 0.0346 0.0248 0.0189 0.0211 0.0477 0.0615 0.0558 0.0286 0.0344 0.0189 0.0182 0.175 0.0346 0.0168 0.0173 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 01/15/07 1830 602159 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 01/12/07 1141 602055 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound 35

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: January 19, 2007

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9506-0000-020F Project:

YANK01204 Sample ID:

178968003 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

QUALITY CONTROL DATA 37

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: January 19, 2007 Page. 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

178968 Parnxame NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 602063 QC1201260616 Americium-241 178968002 DUP Curiurn-242 Curiurn'-243/244 QC1201260618 LCS Americium-241 Curiurn-242 Curiurn-243/244 U

-0.06 Uncert:

+/-0.0683 TPU:

+/-0.0683 U

0.0244 Uncert:

+/-0.0648 TPU:

+/-0.0649 U

-0.0503 Uncert:

+/-0.104 TPU:

+/-0.104 13.5 Uncert:

TPU:

Uncert:

TPU:

16.2 Uncert:

TPU:

U 0.133

+/-0.156

+/-0.157 U

0.046

+/-0.130

+/-0.130 U

-0.229

+/-0.128

+/-0.130 13.8

+/-1.29

+/-2.10 U

-0.0139

+/-0.072

+/-0.072 16.6

+/-1.42

+/-2.44 U

-0.0186

+/-0.0961

+/-0.0961 U

-0.0146

+/-0.0631

+/-0.0632 U

-0.0229

+/-0.149

+/-0.149 pCi/g 529 pCi/g 61 pCi/g 128 pCi/g (0%- 100%) dXA1 01/16/07 08:35 (0%- 100%)

(0%- 100%)

102 (75%-125%)

QC1201260615 Americium-241 MB Curiumn-242 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

pCi/g pCi/g pCi/g pCilg PCilg PCilg PCilg pCilg 102 (75%-125%)

Curiuin-243/244 QC1201260617 Americium-241 178968002 MS Curium-242 13.5 Uncert:

TPU Uncert:

TPU 16.2 Uncert:

TPU U

-0.06

+/-0.0683

+/-0.0683 U

0.0244

+/-0.0648

+/-0.0649 U

-0.0503

+/-0.104

+/-0.104 U

12.3

+/-1.23

+/-1.93 0.00908

+/-0.0688

+/-0.0688 17.4

+/-1.46

+/-2.56 91 (75%-125%)

Curiwn-243/244 107 (75%-125%)

Batch 602064 QC1201260620 178968002 DUP Plutoanium-238 U

-0.0649 U

-0.0718 pCilg 10 (0% - 100%) IXA1 01/15/07 22:24 38

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 602064 Plutonnium-239/240 QC1201260622 LCS Plutonium-238 Plutoniium-239/240 QC 1201260619 MB Plutoniuin-238 Plutonium-239/240 Uncert:

+/-0.0519 TPU:

+/-0.0524 U

-0.104 Uncert:

+/-0.154 TPU:

+/-0.154 Uncert:

TPU:

12.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0649 Uncert:

+/-0.0519 TPU:

+/-0.0524 12.5 U

-0.104 Uncert:

+/-0.154 TPU:

+/-0.154 U

-2.76 Uncert:

+/-11.0 TPU:

+/-11.0

+/-0.0629

+/-0.0636 U

0.287

+/-0.294

+/-0.296 U

0.0719

+/-0.143

+/-0.143 12.0

+/-1.27

+/-1.79 U

0.0347

+/-0.117

+/-0.117 U

-0.0309

+/-0.0302

+/-0.0304 U

0.104

+/-0.180

+/-0.180 12.2

+/-1.57

+/-2.15 U

1.82

+/-9.11

+/-9.11 pCilg 427 (0% - 100%)

(75%-125%)

pCilg pCi/g pCilg pCilg pCi/g pCilg 96 (75%-125%)

QC1201260621 178968002 MS Plutonium-238 (75%-125%)

Plutonium-239/240 98 (75%-125%)

Batch 602065 QC1201260624 178968002 DUP Plutonium-241 QC1201260626 LCS Plutonium-241 pCi/g 0

(0% - 100%) AXIA1 QC1201260623 MB Plutonium-241 141 Uncert:

TPU:

Uncert:

TPU:

142 U

Uncert:

TPU:

115

+/-7.45

+/-13.6 U

-1.65

+/-4.93

+1-4.93 PCi/g pCi/g pCi/g 81 (75%-125%)

01/17/07 01:05 01/17/07 02:39 01/17/07 00:18 01/17/07 01:52 QC1201260625 178968002 MS Plutonium-241 Rad Gamma Spec Batch 602159 QC1201260867 178923021 DUP Actinium-228

-2.76

+/-11.0

+1-11.0 110

+/-18.0

+/-25.0 78 (75%-125%)

0.470

+/-0.112 Uncert:

0.412

+/-0.104

+/-0.104 pCi/g 13 (0% - 100%) MJH1 01/15/07 18:31 39

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 3 of 9 Parnmame NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 602159 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.112 U -1.790E-05 U

-0.00479 Uncert:

+/-0.0485

+/-0.0184 TPU:

+/-0,0485

+/-0.0184 0.270 0.392 Uncert:

+/-0.141

+/-0.254 TPU:

+/-0.141

+/-0.254 0.324 0.330 Uncert:

+/-0.0574

+/-0.0623 TPU:

+/-0.0574

+/-0.0623 U1 0.00 UI 0.00 Uncert:

+/-0.0199

+/-0.0157 TPU:

+/-0.0199

+/-0.0157 U

0.0185 U

0.00344 Uncert:

+/-0.0166

+/-0.0146 TPU:

+/-0.0166

+/-0.0146 U

0.000568 U

0.00334 Uncert:

+/-0.0102

+/-0.0153 TPU:

+/-0.0102

+/-0.0153 U

-0.00941 U

-0.0217 Uncert:

+/-0.0256

+/-0.0346 TPU:

+/-0.0256

+/-0.0346 U

0.0161 U

-0.0145 Uncert:

+/-0.0306

+/-0.0467 TPU:

+/-0.0306

+/-0.0467 U

0.0335 U

0.00826 Uncert:

+/-0.0281

+/-0.0296 TPU:

+/-0.0281

+/-0.0296 0.465 0.425 Uncert:

4/:0.04 6 2

+/-0.0349 TPU:

+/-0.0462

+/-0.0349 0.359 0.305 Uncert:

+/-0.0537

+/-0.0455 TPU:

+/-0.0537

+/-0.0455 U

0.00492 U

0.00257 Uncert:

+/-0.0118

+/-0.0148 TPU:

+/-0.0118

+/-0.0148 U

0.000641 U

0.00442 Uncert:

+/-0.0103

+/-0.0134 TPU:

+/-0.0103

+/-0.0134 7.08 7.71 Uncert:

+/-0.627

+/-0.486 TPU:

+/-0.627

+/-0.486 0.324 0.330 Uncert:

+/-0.0574

+/-0.0623 TPU:

+/-0.0574

+/-0.0623 U

-0.00383 U

0.000361 Uncert:

+/-0.00875

+/-0.0115 pCi/g 199 pCi/g 37 pCi/g 2

pCi/g 42 pCi/g 137 pCi/g 142 pCi/g 79 pCi/g 3690 pCi/g 121 pCi/g 9

pCi/g 16 pCi/g 63 pCi/g 149 pCi/g 9

pCi/g 2

pCi/g 242 (0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0%- 100%)

(0%- 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 40

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 602159 Thallium-208 TPU:

+/-0.00875 0.154 Uncert:

+/-0.0276 TPU:

+/-0.0276

+/-0.0115 0.144

+/-0.0329

+/-0.0329 pCi/g 7

(0%- 100%)

QC1201260868 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.50 Uncert:

TPU:

13.8 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Cobalt-60 Europium-152 Europium-154 Europium-155 U

0.126

+/-0.177

+/-0.177 24.7

+/-0.203

+/-0.203 U

-0.12

+/-0.296

+/-0.296 U

0.00592

+/-0.066

+/-0.066 U

0.0198

+/-0.045

+/-0.045 10.2

+/-0.160

+/-0.160 14.6

+/-0.218

+/-0.218 U

-0.0332

+/-0.0834

+/-0.0834 U

-0.00106

+/-0.0791

+/-0.0791 U

0.00685

+/-0.0603

+/-0.0603 U

0.00459

+/-0.0482

+/-0.0482 U

0.0952

+/-0.0608

+/-0.0608 U

-0.0315

+/-0.0432

+/-0.0432 U

-0.00549

+/-0.0342

+/-0.0342 U

0.0853 pci/g pCilg pCi/g pCi/g pCi/g pci/g pCi/g pci/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g 108 (75%-125%)

106 (75%-125%)

01/15/07 18:31 106 (75%-125%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

41

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (B43) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Timi Rad Gamma Spec Batch 602159 e

Radium-226 Silver-108m Thallium-208 QC1201260866 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.475

+/-0.475 U

0.00592

+/-0.066

+/-0.066 U

0.0179

+/-0.0323

+/-0.0323 U

0.0314

+/-0.0343

+/-0.0343 U

0.025

+/-0.0286

+/-0.0286 U

-0.102

+/-0.0344

+/-0.0344 U

0.0447

+/-0.0589

+/-0.0589 UI 0.00

+/-0.0176

+/-0.0176 U

0.00274

+/-0.00793

+/-0.00793 U

0.00225

+/-0.00842

+/-0.00842 U

-0.00244

+/-0.00918

+/-0.00918 U

0.00949

+/-0.0225

+/-0.0225 U

-0.00214

+/-0.0215

+/-0.0215 U

-0.0128

+/-0.0199

+/-0.0199 UI 0.00

+/-0.013

+/-0.013 U

0.000666

+/-0.0262

+/-0.0262 PCi/g PCi/g PCi/g PCilg PCilg pCilg PCi/g PCilg PCi/g PCi/g PCi/g PCilg PCi/g pCilg PCilg 01/15/07 18:30 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 lead-212 Lead-214 42

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time Rad Gamma Spec Batch 602159 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.00102

+/-0.00755

+/-0.00755 U

0.00487

+/-0.00745

+/-0.00745 UI 0.00

+/-0.0986

+/-0.0986 UI 0.00

+/-0.0176

+/-0.0176 U

-0.0072

+/-0.00721

+/-0.00721 U

0.00917

+/-0.0149

+/-0.0149 pCi/g pCilg pCi/g pCi/g 603226 QC 1201263219 Strontium-90 178968002 DUP 0.056 Uncert:

+/-0.0311 TPU:

+/-0.0312 U

QC1201263221 LCS Strontium-90 QC1201263218 MB Strontium-90 QC1201263220 178968002 MS Strontium-90 Rad Liquid Scintillation Batch 601908 QC1201260284 178924001 DUP Technetium-99 QC1201260286 LCS Technetium-99 QC1201260283 MB Technetium-99 0.0192

+/-0.0281

+/-0.0281 1.97

+/-0.134

+/-0.153 pCi/g 98 (0% - 100%) KSDI 1.81 Uncert:

TPU:

Uncert:

TPU:

5.43 Uncert:

TPU:

U

-0.0156

+/-0.0264

+/-0.0264 pCilga pCi/g pCilg 109 (75%-125%)

01/19/07 09:25 01/19/07 09:38 01/19/07 09:25 0.056

+/-0.0311

+/-0.0312 4.70

+/-0.269

+/-0.387 86 (75%-125%)

0.387 Uncert:

+/-0.187 TPU:

+/-0.188 14.3 Uncert:

TPU:

U 0.311

+/-0.193

+/-0.193 14.0

+/-0.331

+/-0.470 U

-0.00407 pCi/g 22 (0% - 100%).AXP1 pCi/g pCi/g 98 (75%-125%)

01/17/07 15:18 01/17/07 16:52 01/17/07 14:31 43

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 601908 QC1201260285 178924001 MS Technetium-99 Uncert:

TPU:

14.8 Uncert:

TPU:

+/-0.154

+/-0.154 14.8

+/-0.370

+/-0.512 0.387

+/-0.187

+/-0.188 pCi/g 97 (75%-125%)

01/17/07 16:05 Batch 601909 QC1201260288 178923010 DUP Tritium QC1201260290 LCS Tritium QC1201260287 MB Tritium QC1201260289 178923010 MS Tritium U

0.425 Uncert:

+/-1.30 TPU:

+/-1.30 U

1.18

+/-1.38

+/-1.38 pCi/g 0

(0% - 100%) \\IXP1 8.17 Uncert:

TPU:

Uncert:

TPU:

8.31 U

Uncert:

TPU:

6.75

+/-1.04

+/-1.05 U

0.265

+/-0.647

+/-0.647 pCi/g pCi/g pCi/g 83 (75%-125%)

01/15/07 17:06 01/15/07 18:10 01/15/07 16:35 01/15/07 17:38 0.425

+/-1.30

+/-1.30 Batch 601910 QC1201260292 178924001 DUP Carbon-14 QC1201260294 LCS Carbon-14 QC1201260291 MB Carbon-14 QC1201260293 178924001 MS Carbon-14 U

-0.00673 Uncert:

+/-0.119 TPU:

+/-0.119 U

7.56

+/-1.81

+/-1.81

-0.0176

+/-0.116

+/-0.116 7.18

+/-0.216

+/-0.243 91 (75%-125%)

pCi/g 0

(0% - 100%) VrXP1 7.16 Uncert:

TPU:

Uncert:

TPU:

15.8 U

Uncert:

TPU:

U

-0.0566

+/-0.115

+/-0.115 pCi/g pCi/g pCi/g 100 (75%-125%)

01/15/07 20:52 01/15/07 23:00 01/15/07 19:48 01/16/07 08:43

-0.00673

+/-0.119

+/-0.119 Batch 602972 QC1201262580 178924001 DUP Iron-55 U

-17.2 Uncert:

+/-28.4 TPU:

+/-28.4 U

14.9

+/-0.928

+/-0.957

-26.7

+/-23.0

+/-23.0 795

+/-66.3

+/-87.8 94 (75%-125%)

pCi/g 0

(0% - 100%) IXPI 01/18/07 09:26 QC1201262582 LCS Iron-55 799 Uncert:

TPU:

pci/g 100 (75%-125%)

01/18/07 09:59 44

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

178968 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Liquid Scintillation Batch 602972 QC1201262579 MB Iron-55 QC1201262581 178924001 MS Iron-55 Uncert:

TPU:

624 U

Uncert:

TPU:

U 31.7

+/-37.6

+/-37.7 pCi/g pCi/g 01/18/07 09:09 01/18/07 09:42

-17.2

+/-28.4

+/-28.4 546

+/-48.4

+/-63.7 87 (75%-125%)

Batch 602983 QC1201262610 178968002 DUP Nickel-63 QC1201262612 LCS Nickel-63 QC1201262609 MB Nickel-63, QC1201262611 178968002 MS Nickel-63 U

-10.2 Uncert:

+/-11.1 TPU:

+/-11.1 U

-7.47

+/-8.38

+/-8.38 pCi/g 0

(0% - 100%) \\4XP1 518 Uncert:

TPU:

Uncert:

TPU:

585 U

Uncert:

TPU:

468

+/-22.2

+/-27.5 U

-4.74

+/-10.8

+/-10.8 pCi/g pCi/g pCi/g 90 (75%-125%)

01/18/07 10:59 01/18/07 09:04 01/18/07 08:31 01/18/07 08:48

-10.2

+/-11.I

+/-11.1 566

+/-28.7

+/-35.4 97 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A B

BD C

D H

J N/A ND R

U UI A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Analyte concentration is not detected above the detection limit Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 45

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 -- www.gel.com QC Summary Workorder:

178968 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time X

Y QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RE. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

46

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Health Physics Procedure GPP-GGGR-R5121-0O1 Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit:

9506- 0000 Survey Unit Name: North Site Grounds (Non-protected Area)/EOF Classification:

3 Survey Media:

Soil Type of Survey:

Final Status Survey Type of Measurement:

Radionuclide Specific Number of Measurements:

15 Operational DCGL (pCi/g) 6.01E+00 BASIC STATISTICAL QUANTITIES Cs-137 Minimum Value:

-2.11E-02 Maximum Value:

2.52E-01 Mean:

7.99E-02 Median:

5.52E-02 Standard Deviation:

7.1 1E-02 NUMBER 9506-0000-001F 9506-0000-002F 9506-0000-005F 9506-0000-006F 9506-0000-007F 9506-0000-008F 9506-0000-009F 9506-0000-01OF 9506-0000-011F 9506-0000-012F 9506-0000-013F 9506-0000-014F 9506-0000-018F 9506-0000-019F 9506-0000-020F RADIONUCLIDE CONCENTRATION (pCi/g)

Cs-137 Identified?

1.820E-02 Y

8.150E-02 N

1.630E-01 Y

5.090E-02 Y

4.720E-02 Y

5.520E-02 Y

6.370E-02 Y

4.980E-02 Y

-2.11OE-02 N

2.53E-02 N

2.520E-01 Y

4.400E-02 Y

1.760E-01 Y

6.120E-02 Y

1.310E-01 Y

Performed By:

Date:

7 Date:

"2- /12<)j

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-0O1 Attachment C Quantile Plot For Cesium - 137 Survey Unit:

9506-0000 Survey Unit Name: North Site Grounds (Non-protected Area)/EOF Mean:

7.99E-02 pCi/g 3.OOE-01 2.50E-01 U. 2.OOE-01 0o 1.50E-01 I.00E-01 C 5.OOE-02 0

O.OOE+00

-5.O0E-02 Percentage Cs-1 37 Rank Percentage

-2.l1E-02 1

3 %

1.82E-02 2

10 %

2.53E-02 3

17 %

4.40E-02 4

23 %

4.72E-02 5

30 %

4.98E-02 6

37 %

5.09E-02 7

43 %

5.52E-02 8

50 %

6.12E-02 9

57 %

6.37E-02 10 63 %

8.15E-02 11 70%

1.31E-01 12 77 %

1.63E-01 13 83 %

1.76E-01 14 90 %

2.52E-01 15 97 %

I I

Prepared By:

Date:

Date:

//

_/&

Reviewed By: R,

,_,7ý

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs - 137 Survey Unit:

9506-0000 Survey Unit Name: North Site Grounds (Non-protected Area)/EOF Mean:

0.080 pCi/g Upper End Observation Observation %

Value Frequency Frequency 0.00 2

13%

0.25 12 80%

0.50 0

0%

0.75 1

7%

1.00 0

0%

Total 15 100%

Prepared By:

Date:

.2-9-0-7 Reviewed By:

Reviewed By:

Date:

"ý/Date:

'? C) :7

) f -

t=ý

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev.CY-001 MAJOR Sign Test Calculation Sheet for Single Radionuclide Survey Area Number:

9506 Survey Unit Number:

0000 WPIR #:

2.006-0038 Survey Area Name:

North Site Grounds (Non Classification:

3 TYPE I (aerror):

0.05 N:

15 protected Area)/EOF Radionuclides:

1 st Radionuclide Cs-137 DCGL:

6.01E+00 Results 1st DCGL-Results Weighted Sum 1-W Sign Radionuclide (WS)

(pCi/g) 1.82E-02 5.99E+00 0.00 1.00

+1 8.15E-02 5.93E+00 0.01 0.99

+1 1.63E-01 5.84E+00 0.03 0.97

+1 5.09E-02 5.64E+00 0.01 0.99

+1 4.72E-02 5.96E+00 0.01 0.99

+1 5.52E-02 5.95E+00 0.01 0.99

+1 6.37E-02 5.94E+00 0.01 0.99

+1 4.98E-02 5.96E+00 0.01 0.99

+1

-2.11 E-02 6.01E+00 0.00 1.00

+1 2.53E-02 5.98E+00 0.00 1.00

+1 2.52E-01 5.75E+00 0.04 0.96

.+1 4.40E-02 5.96E+00 0.01 0.99

+1 1.76E-01 5.83E+00 0.03 0.97

+1 6.12E-02 5.94E+00 0.01 0.99

+1 1.31 E-01 5.87E+00 0.02 0.98

+1 Number of positive differences (S+)

15 Critical Value 11 Survey Unit Meets the Acceptance Criteria Performed by:

Arthur Hammond Date:

Date:

2/12/2007

-7,0,7 Independent Review by:

Page 1 of I

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area 9506 Survey 0000 Survey North Site Grounds (Non-protected Area)/EOF Unit #:

I Unit Name:

Sample Plan or WPIR#: 2006-038 SML #: 9506-0000-002FS Sample

Description:

Comparison of split samples collected from sample measurement location.42 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9506-0000-002F the comparison sample was 9506-0000-002FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 8.15E-02 2.82E-02 3

NONE-9.41E-02 2.76E-02 1.15 NA K-40 9.65E+00 6.50E-01 15 0.6-1.66 1.07E+01 6.35E-01 1.11 Y

Comments/Corrective Actions: In consideration of Cs-137 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. The agreement level for K-40 was found to be acceptable, no further actions are warranted.

Table is provided to show acceptance criteria used to assess split samples.

Resolution Agreement Range 4

8 16 51 7

15 50 200

> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By:

WPIR - Work Plan and Inspection Record SMIL - Sample Measurement Location designation Page I of 1

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9506 Survey 0000 1 Survey Unit North Site Grounds (Non-protected Area)/EOF Area#:

956 Unit #:

Name:

Sample Plan or WPIR#: 2006-0038 SML #: 9506-0000-008FS Sample

Description:

Comparison of split samples collected from sample measurement location #8 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9506-0000-008F, the comparison sample was 9506-0000-008FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 5.52E-02 1.1OE-02 5

0.5 2

8.91E-02 1.70E-02 1.61 Y

Comments/Corrective Actions: The agreement level for Cs-137 Table is provided to show acceptance criteria used was found to be acceptable, no further actions are warranted.

to assess split samples.

Resolution Agreement Range 4

7 0.50 2.00 8

15 0.60 1.66 16 50 0.75 1.33 51 200 0.80 1.25

> 200 0.85 1.18 Performed By:

eDate:

y*-e dBy:

Date:

z /a/' 7

/

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

NORTH SITE GROUNDS (NON-PROTECTED AREA)/EOF SURVEY UNIT 9506-0000 RELEASE RECORD ATTACHMENT 4E (COMPASS POWER CURVE)

Revision 0

DQA Surface Soil Report Assessment Summary Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples:

Reference Area Samples:

Test Performed:

Judgmental Samples:

Assessment

Conclusion:

9506-0000 Arthur L. Hammond North Site Grounds (Non-Protected Area)/EOF 1

15 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve 0.9 0.8 A

0.7 0.5

~0.4 0.3 S02 t 0.1 10 0

1 2

3 4

5 6

Sail C..utiulhad

(#Cig)6 inchding bwAchpud Prospcte Powr 1-beta Actual Power LBa m

Esae Power SG.

Rerecte Power 7

COMPASS v1.0.0 2/1312007 Page I