IR 05000275/2004009

From kanterella
(Redirected from ML050380538)
Jump to navigation Jump to search
IR 05000275-04-009, IR 05000323-04-009, on 12/13/2004 - 01/14/2005; Pacific Gas and Electric, Co.; Diablo Canyon Nuclear Power Plant Units 1 and 2; Radiation Monitoring Instrumentation and Protective Equipment; Radiological Environmental Mo
ML050380538
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 02/03/2005
From: Shannon M
Plant Support Branch Region IV
To: Rueger G
Pacific Gas & Electric Co
References
IR-04-009
Download: ML050380538 (23)


Text

ary 3, 2005

SUBJECT:

DIABLO CANYON - NRC RADIATION SAFETY TEAM INSPECTION REPORT 05000275/2004009 AND 05000323/2004009

Dear Mr. Rueger:

On December 17, 2004, the NRC completed the Radiation Safety Team inspection at your Diablo Canyon Nuclear Power Plant, Units 1 and 2, facility. The enclosed report documents the inspection findings that were discussed with Mr. P. Roller, Operations Services Director and other members of your staff. On January 14, 2005, a telephonic exit was conducted with Mr. R. Hite, Radiation Protection Manager concerning additional radioactive material control findings.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your operating license. The team reviewed selected procedures and records, observed activities, and interviewed personnel. Specifically, the team evaluated the inspectable areas within the Radiation Protection Strategic Performance Area that are scheduled for review every two years.

These areas are:

  • Radiation Monitoring Instrumentation
  • Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems
  • Radioactive Material Processing and Transportation
  • Radiological Environmental Monitoring Program and Radioactive Material Control Program This inspection report documents one NRC-identified violation and one self-revealing violation.

Both findings are non-cited violations that have been determined to be of very low safety significance (Green). Additionally, two licensee-identified violations, which were determined to be of very low safety significance, are listed in Section 4OA7 of this report. If you contest these non-cited violations or their significance, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, U.S. Nuclear Regulatory Commission Region IV, 611 Ryan Plaza Drive,

Pacific Gas and Electric Company -2-Suite 400, Arlington, Texas 76011-4005; the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington DC 20555-001; and the NRC Resident Inspector at the Diablo Canyon, Units 1 and 2, facility.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

//RA//

Michael P. Shannon, Chief Plant Support Branch Division of Reactor Safety Dockets: 50-275 50-323 Licenses: DPR-80 DPR-82

Enclosure:

NRC Inspection Report 05000275/2004009; 05000323/2004009

REGION IV==

Docket: 50-275 50-323 License: DPR-80 DPR-82 Report No.: 05000275/2004009 05000323/2004009 Licensee: Pacific Gas and Electric Company Facility: Diablo Canyon Nuclear Power Plant, Unit 1 and 2 Location: 7 1/2 miles NW of Avila Beach Avila Beach, California Date: December 13, 2004, through January 14, 2005 Inspectors: Louis C. Carson II, Senior Health Physicist-Team Leader Daniel R. Carter, Health Physicist Gilbert L. Guerra, Resident Inspector, South Texas Project Binesh K. Tharakan, Health Physicist Accompanied By: Larry T. Ricketson, Senior Health Physicist Approved By: Michael P. Shannon, Chief, Plant Support Branch Division of Reactor Safety ATTACHMENT: Supplemental Information Enclosure

SUMMARY OF FINDINGS Diablo Canyon, Units 1 and 2 NRC Inspection Report 05000275/2004009; 05000323/2004009 IR 05000-275-04-09, IR 05000-323-04-09;12/13/2004 - 01/14/2005; Pacific Gas and Electric.

Co.; Diablo Canyon Nuclear Power Plant Units 1 and 2; Radiation Monitoring Instrumentation and Protective Equipment; and Radiological Environmental Monitoring Program and Radioactive Material Control Program The report covered a one week period of inspection on site by a team of three region-based health physics inspectors and a resident inspector. Based on the results of the inspection, the team identified two findings of very low safety significance (Green). The significance of most findings is indicated by their color (Green, White, Yellow, Red) using IMC 0609, Significance Determination Process, (SDP). Findings for which the SDP does not apply may be Green or be assigned a severity level after NRC management review. The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 3, dated July 2000.

A. NRC-Identified and Self-Revealing Findings Cornerstone: Occupational Radiation Safety

  • Green: A self-revealing non-cited violation of 10 CFR 20.1501(a) was identified when the licensee failed to perform an adequate survey to evaluate the radiological hazards associated with venting the steam generator exhaust into containment during the Unit 2 refueling outage. On February 7, 2003, the licensee failed to take air samples to account for the decay of tellurium-132 into iodine-132 in the steam generator exhaust prior to venting into the containment building. Consequently, fifty-two workers in containment received unplanned and unintended low-level intakes (less than 10 millirem) of iodine-132. This issue has been entered into the licensee's corrective action program as Action Request No. A0628334.

The failure to perform a survey to evaluate radiological hazards is a performance deficiency. The finding is more than minor because it affected the Occupational Radiation Safety cornerstone objective to protect worker health and safety from radiation and radioactive materials. This finding was associated with the cornerstone attribute of Exposure Control and involved unplanned and unintended dose to workers that resulted from actions contrary to NRC requirements. Therefore the Occupational Radiation Safety Significance Determination Process was used to analyze the significance of the finding which was determined to be of very low safety significance because it did not involve: (1) ALARA planning and controls, (2) an overexposure, (3) a substantial potential for overexposure, or (4) an impaired ability to assess dose (Section-2OS3).

Enclosure

-2-Cornerstone: Public Radiation Safety C Green: The team identified a non-cited violation of 10 CFR 31.5(c) because the licensee failed to maintain a program for generally-licensed radioactive devices used for reactor operations in accordance with the regulatory requirements. The licensee failed to implement a program for the use of generally-licensed devices used for monitoring personnel, and consequently failed to maintain and test 14 radioactive sources housed within the generally-licensed devices. Specifically, the licensee had not (1) conducted contamination leak tests on the device and the 10-millicurie Nickel-63 source housed in each device at the required frequency and (2) assigned an individual with the regulatory knowledge or authority to ensure compliance with 10 CFR 31.5. This issue has been entered into the licensee's corrective action program as Action Request A0628345.

The licensees failure to control generally-licensed devices containing radioactive material in accordance with 10 CFR 31.5 was a performance deficiency. The finding was more than minor because it affected the Public Radiation Safety cornerstone attribute and affected the associated cornerstone objective. In order to ensure adequate protection of the public health and safety from exposure to radioactive materials released into the public domain, the licensee is required to leak test each generally-licensed device. Using the Public Radiation Safety Significance Determination Process, the finding had very low safety significance (Green) because: (1) it was not a transportation issue, (2) public exposure was not more than 5 millirem, and (3) there were not more than five occurrences. This finding also had crosscutting aspects associated with the effectiveness of problem identification and resolution (Section 2PS3).

Licensee Identified Violations Two violations of very low safety significance, which were identified by the licensee, have been reviewed by the team. Corrective actions taken or planned by the licensee have been entered into the licensees corrective action program. These violations and corrective actions are listed in Section 4OA7 of this report.

Enclosure

Report Details 2. RADIATION SAFETY Cornerstone: Occupational Radiation Safety [OS]

2OS3 Radiation Monitoring Instrumentation and Protective Equipment (71121.03)

a. Inspection Scope This area was inspected to determine the accuracy and operability of radiation monitoring instruments that are used for the protection of occupational workers and the adequacy of the program to provide self-contained breathing apparatus (SCBA) to workers. The team used the requirements in 10 CFR Part 20 and the licensees procedures required by technical specifications as criteria for determining compliance.

The team interviewed licensee personnel and reviewed:

  • Calibration of area radiation monitors associated with transient high and very high radiation areas and post-accident monitors used for remote emergency assessment
  • Calibration of portable radiation detection instrumentation, electronic alarming dosimetry, and continuous air monitors used for job coverage
  • Calibration of whole body counting equipment and radiation detection instruments utilized for personnel and material release from the radiologically controlled area
  • Self-assessments, audits, and Licensee Event Reports
  • Corrective action program reports since the last inspection
  • Licensee action in cases of repetitive deficiencies or significant individual deficiencies
  • Calibration expiration and source response check currency on radiation detection instruments staged for use
  • The licensees capability for refilling and transporting SCBA air bottles to and from the control room and operations support center during emergency conditions, status of SCBA staged and ready for use in the plant and associated surveillance records, and personnel qualification and training
  • Qualification documentation for onsite personnel designated to perform maintenance on the vendor-designated vital components, and the vital component maintenance records for SCBA units Either because the conditions did not exist or an event had not occurred, no opportunities were available to review the following item:
  • Licensee Event Reports.

The team completed 9 of the required 9 samples.

Enclosure

-2-b. Findings Introduction. A Green self-revealing non-cited violation of 10 CFR 20.1501(a) was identified for failure to perform an adequate survey to evaluate the radiological hazards associated with releasing (venting) material from the steam generators to the Unit 2 containment building atmosphere prior to commencing work.

Description. On February 7, 2003, two workers became contaminated while working on the steam generators during Unit-2 Refueling Outage 11. Two workers received personal contamination monitor alarms when they tried to exit the radiologically controlled area. The two workers were directed to report to the dosimetry department for whole body scans and further analyses. After comprehensive whole body scans using sodium iodide and high-purity germanium detectors, the analyses showed that the workers had intakes of iodine-132. The licensee stopped work in containment and performed an investigation to determine the cause of the intakes.

The licensee determined that the steam generator ventilation line-up was changed which vented the steam generators exhaust directly into the containment building and caused the intakes. Earlier in the outage the licensee had successfully vented the steam generator bowls to the atmosphere through the plant vent via the containment ventilation exhaust system to eliminate the initial spike of noble gases and iodine. Later, the licensee decided to change the ventilation line-up to allow steam generator bowls to vent inside the containment building through a particulate filter. However, the licensee failed to evaluate the radiological hazards associated with this action prior to venting the steam generator bowls directly into containment. Primarily, the licensee failed to take an air sample to determine the extent of radiological hazards present and to account for the decay of tellurium-132 into iodine-132 in the steam generator exhaust. This decision resulted in a total of 52 workers receiving intakes (less than 10 millirem) of iodine. The licensee's immediate corrective action was to stop work on the steam generator bowls and resume the previous ventilation line-up. In addition, after determining the extent of the iodine radioactivity in the steam generator exhaust, iodine filters were installed in the steam generator bowl exhaust trunks.

Analysis. The failure to perform an adequate survey to evaluate radiological hazards is a performance deficiency. The finding is more than minor because it affected the Occupational Radiation Safety cornerstone objective to protect worker health and safety from radiation and radioactive materials. This finding was associated with the cornerstone attribute of Exposure Control and involved unplanned and unintended dose to workers that resulted from actions contrary to NRC requirements. The team used the Occupational Radiation Safety Significance Determination Process to analyze the significance of the finding. The team determined that the finding was of very low safety significance because it did not involve: (1) ALARA planning and controls, (2) an overexposure, (3) a substantial potential for overexposure, or (4) an impaired ability to assess dose.

Enclosure

-3-Enforcement. 10 CFR 20.1501(a), states, in part, that each licensee shall make surveys or cause to be made surveys that may be necessary to comply with the regulations in Part 20 and that are reasonable under the circumstances to evaluate the magnitude and extent of radiation levels, concentrations or quantities of radioactive material, and the potential radiological hazards.

Pursuant to 10 CFR 20.1003, a survey means an evaluation of the radiological conditions and potential hazards incident to the production, use, transfer, release, disposal, or presence of radioactive material or other sources of radiation.

Contrary to this requirement, on February 7, 2003, the licensee failed to evaluate the radiological hazards associated with releasing (venting) material from the steam generators to the containment atmosphere to assure compliance with 10 CFR 20.1201(a)(1)(ii), which limits the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue annually. Because the failure to perform an adequate survey was determined to be of very low safety significance and has been entered into the licensees corrective action program as Action Request A0628334 and Non-Conformance Report N0002158, this violation is being treated as a non-cited violation (NCV), consistent with Section VI.A.1 of the NRC Enforcement Policy: NCV 05000323/2004009-01, Failure to perform an adequate survey to evaluate radiological hazards.

Cornerstone: Public Radiation Safety [PS]

2PS1 Radioactive Gaseous And Liquid Effluent Treatment And Monitoring Systems (71122.01)

a. Inspection Scope This area was inspected to ensure that the gaseous and liquid effluent processing systems are maintained so that radiological releases are properly mitigated, monitored, and evaluated with respect to public exposure. The team used the requirements in 10 CFR Part 20, 10 CFR Part 50 Appendices A and I, the Offsite Dose Calculation Manual, and the licensees procedures required by technical specifications as criteria for determining compliance. The team interviewed licensee personnel and reviewed:

  • The most current radiological effluent release reports, changes to radiation monitor setpoint calculation methodology, anomalous sampling results, effluent radiological occurrence performance indicator incidents, self-assessments, audits, and licensee event reports
  • Gaseous and liquid release system component configurations
  • Routine processing, sample collection, sample analysis, and release of radioactive liquid and gaseous effluent; including effluent release permit generation and dose projections to members of the public
  • Abnormal releases Enclosure

-4-

  • Changes made by the licensee to the ODCM, the liquid or gaseous radioactive waste system design, procedures, or operation since the last inspection
  • Monthly, quarterly, and annual dose calculations
  • Surveillance test results involving air cleaning systems and stack or vent flow rates
  • Instrument calibrations of discharge effluent radiation monitors and flow measurement devices, effluent monitoring system modifications, effluent radiation monitor alarm setpoint values, and counting room instrumentation calibration and quality control
  • Measurement Assurance Program (Interlaboratory comparison) results
  • Audits, self-assessments and corrective action reports performed since the last inspection.

Either because the conditions did not exist or an event had not occurred, no opportunities were available to review the following items:

  • Abnormal releases, Licensee Event Reports or special reports.

The team completed 10 of the required 10 samples.

b. Findings No findings of significance were identified.

2PS2 Radioactive Material Processing and Transportation (71122.02)

a. Inspection Scope This area was inspected to verify that the licensees radioactive material processing and transportation program complies with the requirements of 10 CFR Parts 20, 61, and 71 and Department of Transportation regulations contained in 49 CFR Parts 171-180. The Team interviewed licensee personnel and reviewed:

  • The radioactive waste system description, recent radiological effluent release reports, and the scope of the licensees audit program
  • Liquid and solid radioactive waste processing systems configurations, the status and control of any radioactive waste process equipment that is not operational or is abandoned in place, changes made to the radioactive waste processing systems since the last inspection, and current processes for transferring radioactive waste resin and sludge discharges Enclosure

-5-

  • Radio-chemical sample analysis results for radioactive waste streams and use of scaling factors and calculations to account for difficult-to-measure radionuclides
  • Shipment packaging, surveying, labeling, marking, placarding, vehicle checking, driver instructing, and disposal manifesting for Shipment RMS-04-061
  • Shipping records for five non-excepted package shipments
  • Licensee event reports, special reports, audits, state agency reports, self-assessments and corrective action reports performed since the last inspection Either because the conditions did not exist or an event had not occurred, no opportunities were available to review the following items:
  • Licensee event reports, special reports, and state agency reports
  • Changes made to the radioactive waste processing systems since the last inspection The team completed 6 of the required 6 samples.

b. Findings No findings of significance were identified.

2PS3 Radiological Environmental Monitoring Program (REMP) And Radioactive Material Control Program (71122.03)

a. Inspection Scope This area was inspected to ensure that the REMP verifies the impact of radioactive effluent releases to the environment and sufficiently validates the integrity of the radioactive gaseous and liquid effluent release program; and that the licensees surveys and controls are adequate to prevent the inadvertent release of licensed materials into the public domain. The Team used the requirements in 10 CFR Part 20, 10 CFR Part 50, Appendix I, the Offsite Dose Calculation Manual, and the licensees procedures required by technical specifications as criteria for determining compliance.

The Team interviewed licensee personnel and reviewed or observed the following:

  • Review radiological environmental monitoring, meteorological, and radioactive material control programs
  • 2002 and 2003 annual environmental operating reports and licensee audits
  • A sampling of air, water, milk, vegetation, and thermoluminescence dosimeter (TLD) monitoring stations
  • Collection and preparation of environmental samples Enclosure

-6-

  • Operability, calibration, and maintenance of meteorological instruments
  • Each event documented in the 2002 and 2003 Annual Environmental Monitoring Report which involved a missed sample, inoperable sampler, or anomalous measurement
  • Significant changes made by the licensee to the ODCM as the result of changes to the land use census or sampler station modifications
  • Calibration and maintenance records for air samplers and environmental sample radiation measurement instrumentation, quality control program, and interlaboratory comparison program results
  • Radiologically Controlled Area access points and methods used to control, survey, and release materials from radiologically controlled areas
  • Types of radiation monitoring instrumentation used to monitor items released from radiologically controlled areas, criteria used to survey potentially contaminated material, radiation detection sensitivities, procedural guidance, and material release records
  • Selected corrective action documents involving the radiological environmental monitoring, meteorological monitoring, and radioactive material control programs.

The team completed 10 of the required 10 samples.

b. Findings Introduction. The team identified a Green, non-cited violation because the licensee failed to maintain a program for generally-licensed radioactive devices used for reactor operations in accordance with the provisions of 10 CFR 31.5(c).

Description. The licensee possessed and used 14 generally-licensed devices which each contained 10-millicurie Nickel-63 sources. Each device was obtained in accordance with a general license granted under the provisions of 10 CFR 31.5. After interviewing cognizant licensee personnel, the team determined that the licensee had no program to ensure that the devices were maintained in accordance with the requirements of 10 CFR 31.5(c) . Subsequently, the team determined that the licensee had not tested the devices for leakage of radioactive material as required by 10 CFR 31.5(c).

Analysis. The licensees failure to control generally-licensed devices containing radioactive material in accordance with 10 CFR 31.5 was a performance deficiency.

The finding was more than minor because it affected the Public Radiation Safety cornerstone attribute and affected the associated cornerstone objective to ensure adequate protection of the public health and safety from exposure to radioactive materials. Using the Public Radiation Safety Significance Determination Process, the Enclosure

-7-team determined that the finding had very low safety significance (Green) because: (1)

it was not a transportation issue, (2) public exposure was not more than 5 millirem, and (3) there were not more than five occurrences. This finding also had crosscutting aspects associated with the effectiveness of problem identification and resolution (Section 2PS3).

Enforcement. 10 CFR 31.5 (a) grants a general license to commercial firms to possess or use byproduct material contained in devices designed for the purpose if the provisions of 10 CFR 31.5(c) are met. 10 CFR 31.5 (c) requires, in part, that the device be tested for leakage of radioactive material; that records of leak test results be maintained; and requires an appointed individual responsible for having the regulatory knowledge to ensure compliance However, the licensee did not have a program to ensure these devices were in compliance with 10 CFR 31.5 (c). This violation is in the licensees corrective action program as Action Request A0597931. This violation is being treated as a non-cited violation consistent with Section VI.A.1 of the NRC Enforcement Policy: NCV 05000323/2004009-02, Failure to control radioactive material contained in generally-licensed devices in accordance with 10 CFR 31.5.

4. OTHER ACTIVITIES 4OA2 Problem Identification and Resolution a. Inspection Scope The team evaluated the effectiveness of the licensees problem identification and resolution process with respect to the following inspection areas:

  • Radiation Monitoring Instrumentation (Section 2OS3)
  • Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems (Section 2PS1)
  • Radioactive Material Processing and Transportation (Section 2PS2)
  • Radiological Environmental Monitoring Program and Radioactive Material Control Program (Section 2PS3)

b. Findings and Observations Section 2PS3 discusses an example of the licensees lack of effectiveness in problem identification and resolution. Specifically, the licensee did not fully evaluate the fully extent of the problem identified in Action Request A0597931 regarding generally-licensed devices acquired. The licensee had determined that procedures requiring notification of the radiation protection manager were not followed. However, the licensee did not inquire into the number of sources that had been acquired and used onsite. Additionally, the licensee did not ascertain that the radiation sources and generally-licensed devices were properly controlled in accordance with NRC regulations and/or vendor instructions. (Section 2PS3)

Enclosure

-8-4OA6 Meetings Exit Meeting Summary The team presented the inspection results to Mr. P. Roller, Operations Director and other members of licensee management during an exit meeting conducted on December 17, 2004. The licensee acknowledged the findings presented.

On January 14, 2005, the team conducted an exit interview by telephone, and presented additional radioactive material control findings to Mr. R. Hite, Radiation Protection Manager and Mr. L. Parker, Supervisor, Regulatory Services. The licensee acknowledged the findings presented.

The team asked the licensee whether or not any materials examined during the inspection should be considered proprietary. No proprietary information was identified.

4OA7 Licensee Identified Violations

.1 10 CFR 20.1801 requires that the licensee shall secure from unauthorized removal or access licensed materials that are stored in controlled or unrestricted areas. During the review of corrective action documents the team noted in Action Request A0596423 that two Sr-90 0.5 uCi sources were missing from the licensees inventory and could not be found. This violation is in the licensees corrective action program as Action Request A0628379. Using the Public Radiation Safety Significance Determination Process, the team determined that this finding had very low safety significance (Green) because it was not a transportation issue, public exposure was not more than 5 millirem, and there were not more than 5 occurrences.

.2 Technical Specification 5.4.1.a requires written procedures be established, implemented, and maintained covering the activities referenced in Appendix A of Regulatory Guide 1.33, Revision 2, February 1978. Appendix A, Section 7 references procedures for control of radioactivity. Procedure RCP D-614, Release of Solid Materials From Radiologically Controlled Areas, Revision 6A, Section 7.1.1, required, in part, all material released from the radiologically controlled area shall have no detectable licensed radioactivity. During the review of corrective action documents the team noted 14 examples documented in Action Requests involving the release of radioactive material released outside the radiologically controlled area but within the protected area. Detectable contamination was found on personal articles and equipment during the performance of routine surveys and by the use of protected area radiation detection instrumentation. Using the Public Radiation Safety Significance Determination Process, the team determined that the finding had very low safety significance (Green) because it was not a transportation issue, public exposure was not more than 5 millirem, and there were not more than 5 occurrences. These events were documented in the licensees corrective action program as Action Requests A0569316 and A0577295.

Enclosure

ATTACHMENT SUPPLEMENTAL INFORMATION PARTIAL LIST OF PERSONS CONTACTED Licensee T. Bast, Operational Support and Equipment Team Lead J. Becker, Station Director D. Bell, Supervisor, Instrument Calibration C. Belmont, Director, Nuclear Quality Assurance K. Buckman, Engineer, Instrument Systems/Components R. Clark, Team Lead, Radiation Protection C. Dougherty, Senior Engineer, Regulatory Services R. Gagney, Foreman, Radiation Protection J. Harker, Dosimetry and Technical Support Team Lead R. Hite, Manager, Radiation Protection L. Hopson, Manager, Chemical & Engineering Operations R. Jett, Nuclear Quality Analysis and Licensing S. Ketelsen, Manager, Regulatory Services J. Knemeyer, Chemical Engineer, Chemical & Engineering Operations R. Lorenz, Supervisor,Technical & Ecological Services L. Moretti, Supervisor, Radiation Protection L. Parker, Supervisor, Regulatory Services J. Portney, Supervisor, Systems Engineering R. Prigimore, Supervisor, Quality Verification P. Roller, Operations Director L. Sewell, Dosimetry Foreman, Radiation Protection M. Summerville, Radiation Protection Team Leader NRC D. Proulx, Senior Resident Inspector T. Jackson, Resident Inspector Attachment

-2-ITEMS OPENED, CLOSED, AND DISCUSSED Opened None.

Opened and Closed During this Inspection 05000323/200400901 NCV Failure to perform an adequate survey to evaluate radiological hazards (Section 2OS3)

05000323/200400902 NCV Failure to control radioactive material contained in certain generally-licensed devices in accordance with 10 CFR 31.5. (Section 2PS3)

Previous Items Closed None LIST OF DOCUMENTS REVIEWED Section 2OS3: Radiation Monitoring Instrumentation and Protective Equipment Procedures CY2.ID1 Radioactive Effluent Controls Program, Revision 6A MP I-RC15 Calibration of Eberline PCM-1B Personnel Contamination Monitor, Revision 6B MP I-RC24 NE Technology SAM-9 Tool Contamination Monitor Calibration, Revision 1 MP I-RC26 Calibration of Eberline PM7 Portal Radiation Monitor, Revision 1 MP I-RD01 Calibration of Eberline Model RO-2 and RO-2A Ion Chamber Survey Instruments, Revision 4 MP I-RD03 Calibration of Eberline 6112B Teletector G-M Survey Instrument, Revision 8 MP I-RD34 Calibration of MGP AMP-200 Dose Rate Meter, Revision 1 STP I-18P4 Oily Water Separator Effluent Discharge Monitor RM-3: Radiation Source Presentation (Isotopic) Calibration, Revision 2 Attachment

-3-STP I-39-R14.B Plant Vent Discharge Noble Gas RM-14 Radiation Monitor Calibration, Revision 7 STP I-39-R24R.B Plant Vent Discharge Iodine Redundant RM-24 Radiation Monitor Calibration, Revision 8 STP I-39-R30.B Containment High Range Area Monitor RM-30/RM-31 Calibration, Revision 6 RCP D-340 Calibration of Direct Reading Pocket Dosimeters (PICs), Revision 12 RCP-D-770 Filling of Breathing Air Bottles, Revision 10 RCP-D-771 Operation of the Posedon Model P250 Breathing Air Compressor Revision 5 RCP D-353 Operation of the Canberra Fastscan Whole Body Counters, Revision 8 RCP D-981 Operation and Calibration Verification of the 400 Curie J. L. Shepherd Model 89 Shielded Calibrator, Revision 1 Action Requests A0573212 A0573986 A0573988 A0574577 A0575557 A0581750 A0581751 A0582114 A0584475 A0587043 A0590347 A0590864 A0590978 A0592745 A0594075 A0598805 A0599041 A0601693 A0603264 A0605508 A0610356 A0611747 A0611992 A0612187 A0613029 A0613683 A0616348 A0617636 A0619092 A0623566 Quality Audit Report June 11, 2002 Nuclear Procurement Issues Committee Commercial Grade Survey

  1. CGS02-008, Thermo Eberline Instrument Corporation, SQA020046 November 13, 2002 Supplier Requalification Audit 022560062 Thermo Gamma-Metrics May 8, 2003 Nuclear Procurement Issues Committee Joint Audit Report for Canberra Industries, Meriden, CT Calibration Packages Identification Number 05.10.002, Eberline PCM-1B, July 29, 2004 Identification Number 03.25.001, MGP Instruments AMP-200, October 25, 2004 Identification Number 03.07.007, 6112B Teletector, November 30, 2004 Identification Number 06.24.002, SAM-9 Tool Contamination Monitor, October 30, 2004 Identification Number 03.09.008, RO-2 Dose Rate Meter, December 6, 2004 Attachment

-4-Miscellaneous Nonconformance Report N0002158 Radiation Monitor High Alarm Set Point and Alternate Alarm Set Point Change Request for Unit 2 RM-44 Containment Purge Exhaust and Ventilation Isolation Monitor Section 2PS1: Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems Procedures CAP A-5 Liquid Radwaste Management, Revision 36 CAP A-6 Gaseous Radwaste Management, Revision 29 CAP A-8 Off-Site Dose Calculations, Revision 28 CAP E-2 Gas Sampling, Revision 19 CAP E-19 Plant Vent Radioactive Effluent Sampling, Revision 12 CY2 Radiological Monitoring and Controls Program, Revision 5 CY2.ID1 Radioactive Effluent Controls Program, Revision 7 CY2DC1 Radiation Monitoring System High Alarm Setpoint, Revision 1A RCP D-611 Release of Liquids, Sludges, Slurries and Oils from the RCA, Revision 7D Action Requests A0584931 A0588221 A0618840 A0618839 A0619139 A0587895 A0611992 A0615476 A0613029 A0581996 A0599719 A0599721 A0593756 A0619014 A0594658 A0594662 A0600782 A0600819 A0600827 A0600828 A0602016 A0607567 A0619600 A0623205 A0609659 A0609659 A0609738 A0589415 A0595146 A0619139 A0618839 A0620586 A0623568 A0606751 A0588154 A0589223 A0590347 A0593613 A0595263 A0596423 A0597931 A0600015 A0601592 A0622441 A0602319 A0605244 A0609151 A0610002 A0622317 A0622442 A0590347 A0611747 A0613805 A0579667 A0622203 Calibration Packages Work Order Number R0230253, Calibration of 0RM-3 Oily Water Separator Radiation Monitor Work Order Number R0240610, Calibration of RM-14 Plant Vent Radiation Monitor Work Order Number R0240611, Calibration of RM-24 Plant Vent Radiation Monitor Release Permits Unit 1 Containment Sampling, Gaseous Radioactive Waste, from December 15, 2004 Unit 1 Liquid Radioactive Waste Batch from December 14, 2004 Unit-2 Plant Vent Stack Gaseous Radioactive Waste from December 14, 2004 Surveillance Packages STP I-39, Plant Vent Noble Gas RM-14 Radiation Monitor Calibration, Revision 14 STP G-9, General HEPA Filter Bank Penetration Test, Revision 8 Attachment

-5-STP G-10, General Charcoal Filter Bank Penetration Test, Revision 8 STP G-11, Obtaining Charcoal Filter Media for Laboratory Testing (Methyl Iodine), Revision 16 STP 53, Unit 1 Control Room Ventilation System - DOP and Halide Penetration Tests, Revision 13 STP 53, Unit 2 Control Room Ventilation System - DOP and Halide Penetration Tests, Revision 6 STP M-3A, Unit 1 Auxiliary Building Ventilation System - DOP and Halide Penetration Test, Revision 13 STP M-3A, Unit 2 Auxiliary Building Ventilation System - DOP and Halide Penetration Test, Revision 4 STP 41, Fuel Handling Building Ventilation System - DOP and Halide Penetration Tests, Revision

Annual Self-Assessment and Quality Audit Reports June 23-25, 2003 2003 RETS/REMP Workshop January 20 - February 6, 2004 2004 DCPP Radioactive Effluents Program and Offsite Dose Calculation Program Audit Section 2PS2: Radioactive Material Processing and Transportation Transportation Packages and Shipments RWS-03-001, RWS-03-003, RWS-04-001, RWS-04-002, and RWS-04-003 Action Requests A0578207 A061000 A0610613 A0610617 A0623205 A0610594 A0610588 A0602319 A0610580 A0610586 Procedures RP2.DC1, Radioactive Waste Classification Program, Revision 4A RCP RW-3, Radioactive Waste Nuclide Fractions and Correlation Factor Determination, Revision 16A RCP RW-4, Solid Radioactive Waste Shipment, Revision 24 RCP RW-5, Receiving, Loading and Releasing of Transport Vehicle for Radioactive Waste Shipment, Revision 13 RCP RW-8, Radioactive Waste Curie Content Calculations, Revision 4A Attachment

-6-RCP RW-20, Spent Resin Sampling, Revision 4 RCP RW-21, Spent Media Sampling, Revision 4B Audits and Self Assessments 2004 Solid Radioactive Waste Management and Radioactive Material Transportation Program Audit Section 2PS3: Radiological Environmental Monitoring Program and Radioactive Material Control Program Procedures CAP A-8, Off-Site Dose Calculations, Revision 28 CY2, Radiological Monitoring and Controls Program, Revision 5 CY2.ID1, Radioactive Effluent Controls Program, Revision 7 RCP D-610, Control of Radioactive Materials, Revision 11 RCP D-614, Release of Solid Materials from Radiologically Controlled Areas, Revision 6A RCP D-620, Control of Radioactive Sources, Revision 5A RCP EM-1, Radiological Environmental Biological Sampling, Revision 5 RCP EM-2, Radiological Environmental Air Sampling, Revision 7 RCP EM-3, Use of Panasonic Environmental Thermoluminescent Dosimeters, Revision 3A RP1.ID11, Radiological Monitoring Procedure, Revision 6 Work Orders R0255623 Backup Meteorological Facility Equipment Calibration R0260315 Calibration of Primary Meteorological Instrumentation Channels Condition Reports Environmental A0605965 A0611992 A0623289 A0568154 A0576528 A0578716 A0582249 A0582229 A0582170 A0582102 A0576654 A0564876 A0593605 A0593613 A0587728 A0599807 A0600947 A0601369 A0610086 A0615430 A0605965 A0619583 A0619611 A0564876 A0573194 A0584392 A0586755 A0587803 A0587420 A0590649 A0593613 A0621367 A0591860 A0591856 A0591853 A0589633 Attachment

-7-A0588973 A0587803 A0586755 A0582372 Meteorology A0584553 A0585688 A0589580 A0591443 A0591447 A0591943 A0592232 A0594781 A0602499 A0614674 A0614707 Radioactive Material Control V0056562 V0055387 V0055386 V0050487 A0584931 A0577295 A0569316 A0597931 A0622203 A0622442 A0622317 A0625556 A0578953 A0577522 A0577100 A0577098 A0577093 A0576754 A0574698 A0574318 A0579843 A0623594 A0595263 A0615476 A0624523 A0587766 A0585841 A0611992 A0609151 A0622441 A0621942 A0621947 A0621948 A0628379 A0596423 Self-Assessments and Audit Reports August 5, 2002 Radioactive Material Controls June 23-25, 2003 2003 RETS/REMP Workshop January 30, 2004 Self-Assessment of Cal-Poly Environmental Lab August 27, 2004 Performance Testing of TLDs December 16 - 19, 2003 2003 DCPP Dosimetry Laboratory Annual Management Review January 20 - February 6, 2004 2004 DCPP Radioactive Effluents Program and Offsite Dose Calculation Program Audit August 31 - September 23, 2004 2004 Radiological Environmental Monitoring Program Audit Reports 2002 Annual Radiological Environmental Operating Report 2003 Annual Radiological Environmental Operating Report 2002 Annual Radioactive Effluent Release Report 2003 Annual Radioactive Effluent Release Report 2002 Land Use Census 2003 Land Use Census Attachment