December 23, 2004 Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128

SUBJECT:

SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 -

ISSUANCE OF AMENDMENTS ON EQUIPMENT HATCH OPEN DURING REFUEL OPERATIONS (TAC NOS. MC0317 AND MC0318)

Dear Mr. Ray:

The Commission has issued the enclosed Amendment No. 193 to Facility Operating License No. NPF-10 and Amendment No. 184 to Facility Operating License No. NPF-15 for San Onofre Nuclear Generating Station, Units 2 and 3, respectively. The amendments consist of changes to the Technical Specifications (TSs) in response to your application dated August 4, 2003, as supplemented by letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004.

The amendments revise TS 3.9.3, "Containment Penetrations," by adding a note to the limiting condition for operation to permit the containment equipment hatch to be open during core alterations and movement of irradiated fuel inside containment during refueling operations.

A copy of our related Safety Evaluation is also enclosed. The Notice of Issuance will be included in the Commission's next biweekly Federal Register notice.

Sincerely,

/RA/

Bo M. Pham, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 and 50-362

Enclosures:

1. Amendment No. 193 to NPF-10
2. Amendment No. 184 to NPF-15
3. Safety Evaluation cc w/encls: See next page

December 23, 2004 Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128

SUBJECT:

SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 -

ISSUANCE OF AMENDMENTS ON EQUIPMENT HATCH OPEN DURING REFUEL OPERATIONS (TAC NOS. MC0317 AND MC0318)

Dear Mr. Ray:

The Commission has issued the enclosed Amendment No. 193 to Facility Operating License No. NPF-10 and Amendment No. 184 to Facility Operating License No. NPF-15 for San Onofre Nuclear Generating Station, Units 2 and 3, respectively. The amendments consist of changes to the Technical Specifications (TSs) in response to your application dated August 4, 2003, as supplemented by letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004.

The amendments revise TS 3.9.3, "Containment Penetrations," by adding a note to the limiting condition for operation to permit the containment equipment hatch to be open during core alterations and movement of irradiated fuel inside containment during refueling operations.

A copy of our related Safety Evaluation is also enclosed. The Notice of Issuance will be included in the Commission's next biweekly Federal Register notice.

Sincerely,

/RA/

Bo M. Pham, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-361 and 50-362

Enclosures:

1. Amendment No. 193 to NPF-10
2. Amendment No. 184 to NPF-15
3. Safety Evaluation cc w/encls:

See next page DISTRIBUTION PUBLIC PDIV-2 r/f GHill (4)

RidsNrrDlpmLpdiv (HBerkow)

RidsNrrPMBPham RidsNrrLADBaxley RidsAcrsAcnwMailCenter RidsOgcRp JUhle RDennig TBoyce JDonohew WBlumberg BHarvey RTaylor RidsNrrDlpmLpdiv2 (RGramm)

RidsNrrDlpmDpr (BPham)

RidsRgn4MailCenter (KKennedy)

Package No.: ML043570497 Amd 193 - Tech Specs No.: ML043630508 Amd 184 - Tech Specs No.: ML043630506 Nrr-100 ACCESSION NO: ML043570481 Nrr-058 OFFICE PDIV-2/PM PDIV-1/LA IROB/SC SRXB-A/SC SPSB-C/SC OGC PDIV-2/SC NAME BPham DBaxley TBoyce JUhle RDennig RHoefling RGramm DATE 11/16/04 12/14/04 11/12/04 10/25/04 11/8/04 11/29/04 12/22/04 OFFICIAL RECORD COPY

SOUTHERN CALIFORNIA EDISON COMPANY SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE, CALIFORNIA THE CITY OF ANAHEIM, CALIFORNIA DOCKET NO. 50-361 SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 193 License No. NPF-10 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Southern California Edison Company, et al.

(SCE or the licensee), dated August 4, 2003, as supplemented by letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-10 is hereby amended to read as follows:

(2)

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 193, are hereby incorporated in the license. Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 60 days of issuance, including the incorporation of the changes to the Technical Specification Bases as described in the licensee's letters dated August 4 and December 24, 2003, and June 3, August 24, and October 6 and 22, 2004.

FOR THE NUCLEAR REGULATORY COMMISSION

/RA/

Robert Gramm, Chief, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: December 23, 2004

ATTACHMENT TO LICENSE AMENDMENT NO. 193 FACILITY OPERATING LICENSE NO. NPF-10 DOCKET NO. 50-361 Replace the following page of the Appendix A Technical Specifications with the attached revised page. The revised page is identified by amendment number and contains marginal lines indicating the areas of change.

REMOVE INSERT 3.9-4 3.9-4

SOUTHERN CALIFORNIA EDISON COMPANY SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE, CALIFORNIA THE CITY OF ANAHEIM, CALIFORNIA DOCKET NO. 50-362 SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 184 License No. NPF-15 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Southern California Edison Company, et al.

(SCE or the licensee) dated August 4, 2003, as supplemented by letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-15 is hereby amended to read as follows:

(2)

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 184, are hereby incorporated in the license. Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 60 days of issuance, including the incorporation of the changes to the Technical Specification Bases as described in the licensee's letters dated August 4 and December 24, 2003, and June 3, August 24, and October 6 and 22, 2004.

FOR THE NUCLEAR REGULATORY COMMISSION

/RA/

Robert Gramm, Chief, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: December 23, 2004

ATTACHMENT TO LICENSE AMENDMENT NO. 184 FACILITY OPERATING LICENSE NO. NPF-15 DOCKET NO. 50-362 Replace the following page of the Appendix A Technical Specifications with the attached revised page. The revised page is identified by amendment number and contains marginal lines indicating the areas of change.

REMOVE INSERT 3.9-4 3.9-4

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO. 193 TO FACILITY OPERATING LICENSE NO. NPF-10 AND AMENDMENT NO. 184 TO FACILITY OPERATING LICENSE NO. NPF-15 SOUTHERN CALIFORNIA EDISON COMPANY SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE, CALIFORNIA THE CITY OF ANAHEIM, CALIFORNIA SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 DOCKET NOS. 50-361 AND 50-362

1.0 INTRODUCTION

By application dated August 4, 2003, as supplemented by letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004, Southern California Edison Company (the licensee) requested changes to the Technical Specifications (TSs) for the San Onofre Nuclear Generating Station (SONGS), Units 2 and 3. The proposed amendments would revise TS 3.9.3, "Containment Penetrations," by adding a note to the limiting condition for operation to permit the containment equipment hatch to be open during core alterations and movement of irradiated fuel inside containment during refueling operations.

The supplemental letters dated December 24, 2003, and June 3, August 24, and October 6 and 22, 2004, provided additional information that clarified the application, did not expand the scope of the application as originally noticed, and did not change the NRC staff's original proposed no significant hazards consideration determination as published in the Federal Register on September 18, 2003 (68 FR 54752).

2.0 REGULATORY EVALUATION

The licensee's description of the proposed amendment, and the technical and regulatory analyses in support of its proposed amendment are described in Sections 2.0, 4.0 and 5.2 of to the licensee's August 4, 2003, application.

The NRC staff finds that the licensee in Section 5.2 of its submittal identified applicable regulatory requirements. The proposed amendments would allow the equipment hatch to be open during refueling operations when there are core alterations or movement of irradiated fuel assemblies inside containment. Based on this, the proposed amendments involve the staffs evaluation of the licensees design basis fuel handling accident (FHA) inside containment, and containment integrity (i.e., the equipment hatch is part of the containment pressure boundary),

during refueling operations or Mode 6.

Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix A, General Design Criterion (GDC) 19, Control Room, requires that licensees maintain the control room in a safe condition under accident conditions. Under these conditions, the licensee must provide adequate radiation protection to permit access and occupancy of the control room.

10 CFR 100.11, Determination of exclusion area, low population zone and population center distance, on the other hand, establishes the dose limits for the exclusion area and for the public.

In order to show that the radiation doses, onsite and offsite, will meet the above regulatory requirements, licensees have performed evaluations of their accident radiation doses.

Regulatory guidance for these evaluations is provided in the form of regulatory guides (RGs) and standard review plans (SRPs). The regulatory requirements from which the NRC staff based its review are contained in 10 CFR Part 50, Appendix A, GDC 19 and 10 CFR 100.11, as supplemented by SRP 6.4, "Control Room Habitability System." Except where the licensee proposed a suitable alternative, the NRC staff used the regulatory guidance provided in the following documents in performing this review.

RG 1.145, Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants.

RG 1.194, Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants.

RG 1.25, "Assumptions Used for Evaluating the Potential Radiological Consequences of a Fuel Handling Accident in the Fuel Handling and Storage Facility for Boiling and Pressurized Water Reactors."

SRP 6.4, "Control Room Habitability System."

The NRC staff also considered relevant information in the SONGS Updated Final Safety Analysis Report (UFSAR), TSs, responses to Generic Letter (GL) 2003-01, Control Room Habitability, and the licensees August 4, 2003, submittal and its supplements.

3.0 TECHNICAL EVALUATION

The NRC staff has reviewed the licensee's regulatory and technical analyses in support of its proposed license amendments which are described in Sections 2.0 and 4.0 of Enclosure 2 to the licensee's August 4, 2003, submittal and its supplements.

As stated in its application, the licensee proposes to add the following note to LCO 3.9.3:

The equipment hatch may be open if all of the following conditions are met:

1.

The Containment Structure Equipment Hatch Shield Doors are capable of being closed within 30 minutes, 2.

The plant is in Mode 6 with at least 23 feet of water above the reactor vessel flange, 3.

A designated crew is available to close the Containment Structure Equipment Hatch Shield Doors, 4.

Containment purge is in service, and 5.

The reactor has been subcritical for at least 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

The licensee stated that the proposed change is to permit the containment equipment hatch to remain open during core alterations and movement of irradiated fuel assemblies inside containment during refueling outages. This is currently not permitted by TS 3.9.3.

The postulated accident that could result in a release of radioactive material through the equipment hatch would be an FHA inside containment, as discussed in the evaluation below.

3.1 Administrative Controls The licensee has proposed to have both the equipment hatch and the missile shield doors open during core alterations or fuel movement inside containment. However, the missile shield doors, under administrative controls, would be maintained in an isolable condition (i.e., capable of being closed) and such controls would require the following in place:

The missile shield doors are capable of being closed in 30 minutes.

A designated crew is available to close the containment structure equipment hatch shield doors.

Flashing would be added to the top and sides of the shield doors to retard or restrict a release of post-accident fission products when the doors are closed.

The capability to close the shield doors includes requirements that any cables or hoses across the opening have quick disconnects to ensure the doors are capable of being closed in the 30 minutes.

The 30-minute closure time is considered to begin when the control room communicates the need to shut the containment structure equipment hatch shield doors.

In its application, the licensee explained that the licensed operator supervising the movement of the irradiated fuel assemblies is in constant communication with the control room and is procedurally required to inform the control room that the containment evacuation alarm be sounded in the event of an FHA inside containment which requires the personnel inside containment to evacuate.

In its supplemental letter of December 24, 2003, the licensee stated that the designated crew would be part of the routine crew used to take in and out equipment from containment through the equipment hatch, and the requirements for this crew would be specified in administrative procedures. The crew would be stationed in the vicinity of the open equipment hatch for the unit in refueling. This may include the area as far away as the opposite unit equipment hatch where equipment is stored waiting to go in containment or place equipment being moved out of containment. These storage areas are within a few hundred feet of the open equipment hatch and the time it takes to respond from these locations will not significantly impact the time it takes to achieve closing of the missile shield doors.

A description of the administrative controls is given in the licensee's application and will be added to the Bases of the TSs.

In justifying the 30-minute closure time for the shield doors, the licensee stated that, at the conclusion of the last Unit 3 refueling outage on February 12, 2003, engineering and licensing personnel observed maintenance personnel closing the missile shield doors. The licensee states that this closure was completed within 30 minutes under what the licensee called the extremely adverse conditions of a rainstorm without the pre-staging of manual chainfalls used to close the doors.

3.2 Tornado Missiles The missile shield doors and the equipment hatch provide missile protection for inside the containment. During Modes 1 through 4, when containment integrity is required, the missile shield covers the equipment hatch. The equipment hatch shield doors are designed for protection against tornado generated missiles. The tornado-generated missiles considered are provided in UFSAR Table 3.5-6.

In addressing what will happen on site during refueling with severe weather in the vicinity of the plant, the licensee, by letter dated August 24, 2004, stated that abnormal operating instructions are in place to verify that missile barrier doors are closed, including the missile shield doors for severe weather. The licensee stated that the conditions that require entry into this procedure include tornado warning, hurricane watch, flash flood watch or warning, or tsunami warning.

3.3 Postulated Accidents The limiting event during refueling when there are core alterations or movement of irradiated fuel inside containment is the FHA inside containment. The licensee has described this event in Sections 15.7.3.9 and 15.10.3.9 of the UFSAR and the NRC staffs acceptance criteria is given in Sections 6.4 and 15.7.4 of the SRP. The dose models used by the licensee to evaluate the consequences of accidents, including the FHA inside containment, are contained in UFSAR Appendices 15B and 15.10B.

The licensees calculated potential dose consequences for the FHA inside containment at the exclusion area boundary (EAB) and the assumptions used for the calculated dose consequences are in Tables 1 and 2, respectively, attached to this safety evaluation (SE).

By letters dated February 28, 1995, and October 8, 1996, the NRC staff issued SEs for SCEs amendment requests to allow both doors of the containment personnel hatch to be open during refueling operations and to allow an upgrade or replacement of containment area and airborne radiation monitoring instrumentation, respectively. In both of these amendments, the NRC staff conducted reviews of SONGSs FHA analysis for dose consequences. However, SCE has since re-analyzed the FHA described in the SONGS UFSAR Chapter 15 accidents. The re-analyses include changes in the release characteristics from the containment, and an increase the amount of unfiltered inleakage assumed to enter into the control room. These changes alter the releases during a FHA and the offsite and control room doses, and is therefore, evaluated in this SE.

3.3.1 FHA Radiological Consequence Analysis Prior to January 2000, SONGSs FHA licensing basis assumed that a fuel bundle dropped onto the ground would result in all 236 fuel pins of the bundle failing, releasing fission product gases from all 236 failed fuel pins. In 2000, SCE updated its FSAR, revising its FHA assumptions to reflect a more mechanistic approach in determining the number of failed pins. The current SONGS FHA analysis postulates that a more realistic worst-case FHA scenario would result from a spent fuel assembly dropped onto a partially filled core during refueling, causing a total of 226 fuel pins to fail. This analysis is described in Section 15.10.7.3.9 of the licensees UFSAR.

In determining the consequences of a FHA, the determination of the amount of iodine contained in the damaged fuel assemblies is highly dependent on the design and operation of the reactor core. In SCE's FHA analysis of record (AOR), the licensee applies conservative and bounding values for the radial peaking factor (RPF) and relative power density (RPD). The RPF and RPD reflect the overall power production in individual fuel rod pins and entire fuel assemblies, respectively. For its FHA, the licensee's AOR assumes the bounding RPF for the dropped assembly is 1.71 and the maximum RPD for the impacted assembly is 1.37.

During each reload analysis, the licensee calculates the maximum cycle-specific RPF and RPD and verifies that each is lower than the value assumed in the FHA AOR. The licensee uses an NRC-approved reload analysis methodology (Reference 1) which incorporates the NRC-approved ROCS-MC computer code for determining the cycle-specific maximum RPF and RPD. The licensee controls the reload analysis process through procedure SO23-XXXVI-2.10, Core Reload Analyses and Activities Checklist. The licensee stated that Section 1.5 of this procedure addresses the reload cycle dose analysis validation for the FHA. Additionally, the licensee stated that the reload cycle dose analysis validation includes verification of the input parameters, including the peaking factors modeled in the current FHA dose analysis.

The licensee's FHA AOR assumes that the dropped assembly will fail 16 fuel rods due to the impact and conservatively applies the bounding 1.71 RPF to all 16 rods. In its reload analysis, the licensee verifies that the maximum cycle-specific RPF calculated is bounded by the 1.71 value assumed in the AOR. Likewise, the licensee's FHA AOR assumes, that in the impacted assembly, an additional 210 fuel rods will fail due to the force of the impact. For these fuel rods, the licensee calculates and verifies that the maximum cycle-specific RPD for any fuel assembly loaded in the core is less than 1.37.

In 1972, the NRC published RG 1.25, "Assumption Used for Evaluating the Potential Radiological Consequences of a Fuel Handling Accident in the Fuel Handling and Storage Facility for Boiling and Pressurized Water Reactors." RG 1.25 states that the appropriate iodine gap release fraction to be assumed in a FHA is 10 percent. In 1988, the NRC issued NUREG/CR-5009, "Assessment of the Use of Extended Burnup Fuel in Light Water Power Reactors," which concluded that the 10 percent assumption listed RG 1.25 was appropriate for low burnup fuel but that the iodine gap release fraction should be increased by 20 percent-to 12 percent-for high burnup fuel. The licensee's FHA AOR assumes and applies the more conservative 12 percent iodine gap release fraction to both low and high burnup fuel. This provides additional margin in assuring that the licensee will satisfy the 10 CFR Part 100 dose requirements.

In SONGSs FHA analysis, the fuel rods, as described above, are conservatively assumed to rupture, releasing the radionuclides within the fuel rod to the reactor cavity water. Volatile constituents of the core fission product inventory migrate from the fuel pellets to the gap between the pellets and the fuel rod clad. The fission product inventory in the fuel rod gap of the damaged fuel rods is assumed to be instantaneously released because of the accident.

Fission products released from the damaged fuel are decontaminated by passage through the overlaying water in the reactor cavity depending on their physical and chemical form. The licensee assumed no decontamination for noble gases, an overall effective decontamination factor of 100 for radioiodines, and retention of all particulate fission products. SCE also assumed that essentially 100 percent of the fission products released from the reactor cavity are released to the environment in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> without any credit for filtration.

The assumptions provided by SCE are presented in Table 2, and the EAB and control room doses estimated by the licensee for the FHA were found to be acceptable. The NRC staff performed independent calculations using the SCE assumptions and confirmed the licensees conclusions.

3.3.1.1 Atmospheric Dispersion Estimates SCE performed the reanalyses of the FHA using the same control room and EAB atmospheric dispersion factors (/Q values) used in the previous FHA analyses described in SONGS UFSAR Chapter 15. A description of the development of these /Q values is provided in SONGS UFSAR Chapter 2.3.4. The UFSAR control room atmospheric dispersion factor of 3.1x10!3 sec/m3 is based on the Murphy & Campe diffuse source-point receptor model (Reference 2) whereas the UFSAR EAB atmospheric dispersion factor of 2.72x10!4 sec/m3 is generally based on the five percent overall site /Q value (excluding the effects of plume meander) described in RG 1.145.

In Question 17 of the request for additional information (RAI) letter dated November 7, 2003, the NRC staff commented on the use of the UFSAR Murphy & Campe diffuse source-point receptor control room atmospheric dispersion factor for the FHA open containment scenario.

The NRC staff stated that this /Q value (3.1x10!3 sec/m3) is applicable when activity is assumed to leak from many points on the surface of the containment in conjunction with a single point receptor (e.g., control room air intake); that is, the activity is assumed to be homogeneously distributed throughout the containment and the release rate is assumed to be reasonably constant over the surface of the building. This is not the situation in the SONGSs postulated FHA scenario, where the release is assumed to occur through the open containment equipment hatch. Consequently, the licensee was asked to justify the use of the UFSAR Murphy & Campe diffuse source-point receptor /Q value of 3.1x10!3 sec/m3 in its FHA open containment dose analysis.

In its RAI response to the NRC staff, dated June 3, 2004, SCE stated that a new set of control room /Q values were calculated for comparison with the UFSAR control room /Q value of 3.1x10!3 sec/m3 using the guidance in RG 1.194. This new set of control room /Q values was calculated using the ARCON96 computer code (Reference 3).

The licensee used 10 years of hourly onsite meteorological data collected during calendar years 1993 to 2002 in order to generate the ARCON96 /Q values. Wind speed and wind direction were measured at 10 and 40 meters above ground level and atmospheric stability classification was based on temperature difference measurements between these two levels.

Section 2.3.3.1 of the SONGS UFSAR states that the onsite meteorological measurement system is consistent with the recommendations of RG 1.23, Onsite Meteorological Programs.

SCE provided an electronic copy of the hourly meteorological data used as input to the ARCON96 computer runs as well as copies of the resulting ARCON96 output in its RAI response Letter dated October 6, 2004. The NRC staff performed a perfunctory review of a subset of the ARCON96 hourly meteorological data base using the methodology described in NUREG-0917 (Reference 4). Further review was performed using computer spreadsheets.

The data recovery rate during the ten-year period 1993-2002 exceeded the RG 1.23 goal of 90 percent. Examination of the data revealed that stable and neutral atmospheric conditions were generally reported to occur at night and unstable and neutral conditions were generally reported to occur during the day, as expected. Wind speed, wind direction, and stability class frequency distributions were reasonably similar from year to year, with the exception that the average lower and upper level wind speeds in 1999 were approximately 1.8 times higher than the lower and upper level wind speeds averaged over the remaining 9-year period (1993-1998 and 2000-2002). This discrepancy in wind speed values does not have a significant impact on the conclusion of this analysis, since the resulting bounding ACRON96 /Q value is only approximately 25 percent of the 3.1x10!3 sec/m3 UFSAR control room /Q value for this license amendment request.

The NRC staff qualitatively reviewed the inputs to the ARCON96 computer runs and found them generally consistent with site configuration drawings and NRC staff practice. Six release-receptor combinations representing two release locations (Units 2 and 3 containment equipment hatches) and three receptors (control room normal, Unit 2 and 3 emergency air intakes) were evaluated. The containment equipment hatch releases were modeled as a ground level area (diffuse) source. Leakage was assumed to occur through the open hatch and the source dimensions were based on the face area of the equipment hatch. The initial diffusion coefficients were determined by dividing the source dimensions by a factor of six in accordance with RG 1.194. The release height was set to the mid-height of the equipment hatch and the distance-to-receptor was set as the shortest path around the containment.

Atmospheric dispersion factors were calculated assuming flow both around and over (or through) the containment building and the resulting highest /Q value was used.

A comparison of the resulting bounding (highest) 0-2 hour ARCON96 /Q value (7.99x10!4 sec/m3) with the UFSAR control room /Q value of 3.1x10!3 sec/m3 shows that the use of the UFSAR control room /Q value in the dose analysis for this license amendment request is conservative. However, because of the potential discrepancy in wind speed data revealed during the NRC staffs perfunctory review of a subset of the 1993-2002 onsite meteorological data, the NRC staff does not endorse the use of this data set in other future licensing actions without further review. Notwithstanding this, the NRC staff concludes that the conservatism of SONGSs UFSAR control room /Q value bounds the ARCON96 results and is conservative.

With respect to the EAB /Q value of 2.72x10!4 sec/m3, the licensee had previously used this value in its FHA dose analyses as contained in the SONGS UFSAR Chapter 15. The NRC staff has reviewed the licensees use of this existing UFSAR EAB /Q value and has found it to be appropriate for the application in which it is being used without change. On the basis of this review, the staff concludes that this EAB /Q value is acceptable for use in this license amendment request.

3.3.1.2 Control Room Doses and Unfiltered Inleakage The NRC staff is currently working toward resolution of generic issues related to control room habitability, in particular, the validity of control room inleakage rates assumed by licensees in analyses of control room habitability. The NRC staff issued GL2003-01, Control Room Habitability, on June 12, 2003. SCE responded to this GL by letter dated September 17, 2004.

In its response, SCE reported that inleakage testing using the ASTM E741 tracer gas methodology determined a control room unfiltered inleakage rate of 259 cfm during the duel train pressurization mode (Train A and B both operating). The proposed values assumed for the FHA are provided in Table 2. These values plus 10 cfm for ingress and egress are larger than the measured values reported in the licensees tracer gas test results.

The NRC staff is still reviewing SCEs September 17, 2004, response for final resolution of GL 2003-01. However, the NRC staff has determined that there is reasonable assurance that the SONGS control room would be habitable during the design basis FHA, and that an evaluation of the licensees current amendment requests can be made prior to final resolution of the generic issue. The NRC staff made this determination based on (1) the results of the tracer gas testing at SONGS, (2) the independent confirmatory calculations performed by the NRC staff, and (3) the available margin between the licensees FHA assumed inleakage (1000 cfm) and the actual measured inleakage (259 cfm). The NRC staff believes the margin gap was necessary to adequately demonstrate conservatism in the licensees assumption, since the 259 cfm was actually calculated based on single train inleakage measurements rather than through direct measurement during dual train operation (i.e., in the case that the most limiting condition existed in dual train operation). This SEs finding, that SCEs assumptions for control room doses and unfiltered inleakage during the FHA are acceptable, is limited to only the scope of this amendments request. As the NRC staff continues its review of GL 2003-01, additional information may be necessary to supplement the licensees September 17, 2004, response letter. Any future resolution will be addressed in separate correspondence once review of the generic issue for SONGS is complete.

3.3.1.3 Offsite Doses The EAB and control room doses estimated by SCE for the FHA were found to be acceptable.

The NRC staff performed independent calculations and confirmed the licensees conclusions.

3.3.1.4 Conclusions As described above, the NRC staff reviewed the assumptions, inputs, and methods used by the licensee to assess the impacts of the proposed change to the SONGS TSs. Based on its review, the NRC staff finds that the licensee used analysis methods and assumptions consistent with the conservative regulatory requirements and guidance identified in Section 2.0, above. The NRC staff finds, with reasonable assurance, that the licensees estimates of the control room doses would continue to comply with GDC 19 (5 rem whole body or 30 rem thyroid). The NRC staff also finds, with reasonable assurance, that the licensees estimates of the EAB doses would continue to be well within 10 CFR Part 100 (6.3 rem whole body and 75 rem thyroid). Therefore, the proposed license amendment is acceptable with regard to the radiological consequences of the postulated FHA.

The NRC staff has reviewed the description of the administrative controls in the licensee's application and concludes that the description is acceptable. In its June 3, 2004, supplemental letter, the licensee agreed to add this description to the TS Bases during the implementation of the amendments. This will be a condition of the amendment to the operating licenses.

Therefore, when the amendments are incorporated into the TSs, the description of the administrative controls will become a part of the Bases of the TSs. Any changes to the description of the administrative controls will be controlled by Section 5.5.14 of the Administrative Controls Section of the TSs.

4.0 STATE CONSULTATION

In accordance with the Commission's regulations, the California State official was notified of the proposed issuance of the amendment. The State official had no comments.

5.0 ENVIRONMENTAL CONSIDERATION

The amendments change a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20. The NRC staff has determined that the amendments involve no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendments involve no significant hazards consideration, and there has been no public comment on such finding published September 18, 2003 (68 FR 54752). Accordingly, the amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendments.

6.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendments will not be inimical to the common defense and security or to the health and safety of the public.

7.0 REFERENCES

1.

Document SCE-9801-P-A, Reload Analysis Methodology for the San Onofre Nuclear Generating Station Units 2 and 3, June 1999.

2.

Murphy, K. G. and Campe, K. M., Nuclear Power Plant Control Room Ventilation System Design for Meeting General Design Criterion 19, Proceedings of the 13th AEC Air Cleaning Conference held August 12-15, 1974, CONF 740807, Vol. I, pp. 401-430.

3.

Ramsdell, Jr., J. V. and Simonen, C. A., Atmospheric Relative Concentrations in Building Wakes, NUREG/CR-6331, Rev. 1, May 1997.

4.

Snell, W., Nuclear Regulatory Commission Staff Computer Programs for Use with Meteorological Data, NUREG-0917, July 1982.

Attachments: 1.

Table 1, Calculated Radiological Dose Consequences

2.

Table 2, Parameters and Assumptions Used in Analysis of Radiological Dose Consequences Principal Contributors: J. Donohew W. Blumberg B. Harvey R. Taylor Date: December 23, 2004

Table 1 Calculated Radiological Dose Consequences Exclusion Area Boundary Dose SRP 15.7.4 Limits Whole Body 0.3 Rem 6 Rem Thyroid 56.4 Rem 75 Rem Control Room Operator Dose GDC 19 Limits Whole Body 0.3 Rem 5 Rem Thyroid 25.4 Rem Equivalent to 5 Rem Whole Body (30 Rem per SRP Section 6.4)

a2.72E-4 is to be read 2.72 x 10-4 Table 2 (sheet 1 of 2)

Parameters and Assumptions Used in Analysis of FHA (Accident in Containment with Equipment Hatch Open)

Core thermal power, MWt 3458 Time between plant shutdown and accident, hrs.

72 Fraction of Gap Activity Released to the Refueling Cavity Water, %

100 Minimum Water Depth Above Reactor Vessel Flange (and damaged fuel rods), feet 23 Refueling Cavity Water Decontamination Factors:

Noble Gases 1

Iodine 100 Airborne Iodine Forms, %

Elemental 75 Organic 25 Exclusion Area Boundary Parameters Atmospheric Relative Concentration, sec/m3 2.72E-4a Dose Conversion Factors ICRP-30 EAB Breathing Rate, m3/sec 3.47E-4 EAB Occupancy Factor (0-2 hours) 1.0

b 990 ft3/min does not include unfiltered inleakage due to ingress and egress.

Table 2 (sheet 2 of 2)

Parameters and Assumptions Used in Analysis of FHA (Accident in Containment with Equipment Hatch Open)

Control Room Parameters Atmospheric Relative Concentration, sec/m3 3.1E-3 Dose Conversion Factors ICRP-30 Control Room Breathing Rate m3/sec 3.47E-4 Control Room Occupancy Factor 1.0 Control Room Volume, ft3 266,920 Unfiltered ingress/egress rate, ft3/min 10 Unfiltered Inleakage Rate, ft3/min 990b Control Room Normal HVAC System Operation (0 - 3 min):

Normal Operation Unfiltered Inflow Rate, ft3/min 5820 Control Room Isolation (switchover to CREACUS),

min.

3 Control Room CREACUS Operation (3 min. - 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />):

Filtered Inflow Rate, cfm 4,400 Inflow and Recirculation Filter Efficiencies, %

Elemental Iodine 95 Organic Iodide 95 Particulate 99

San Onofre Nuclear Generating Station, Units 2 and 3 cc:

Mr. Raymond Waldo, Plant Manager Nuclear Generation Southern California Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, CA 92674-0128 Mr. Douglas K. Porter Southern California Edison Company 2244 Walnut Grove Avenue Rosemead, CA 91770 Mr. David Spath, Chief Division of Drinking Water and Environmental Management P. O. Box 942732 Sacramento, CA 94234-7320 Chairman, Board of Supervisors County of San Diego 1600 Pacific Highway, Room 335 San Diego, CA 92101 Eileen M. Teichert, Esq.

Supervising Deputy City Attorney City of Riverside 3900 Main Street Riverside, CA 92522 Mr. Gary L. Nolff Power Projects/Contracts Manager Riverside Public Utilities 2911 Adams Street Riverside, CA 92504 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Mr. Michael Olson San Diego Gas & Electric Company P.O. Box 1831 San Diego, CA 92112-4150 Mr. Ed Bailey, Chief Radiologic Health Branch State Department of Health Services Post Office Box 997414 (MS7610)

Sacramento, CA 95899-7414 Resident Inspector/San Onofre NPS c/o U.S. Nuclear Regulatory Commission Post Office Box 4329 San Clemente, CA 92674 Mayor City of San Clemente 100 Avenida Presidio San Clemente, CA 92672 Mr. Dwight E. Nunn, Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128 Mr. James D. Boyd, Commissioner California Energy Commission 1516 Ninth Street (MS 31)

Sacramento, CA 95814 Mr. Joseph J. Wambold, Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92764-0128 Mr. Steve Hsu Department of Health Services Radiologic Health Branch MS 7610, P.O. Box 997414 Sacramento, CA 95899 6/04