MONTHYEARML24177A1892024-06-28028 June 2024 Summary of Information Meeting with Question and Answer Session to Discuss the 2023 Annual Assessment of Safety Performance at Columbia Generating Station ML23156A2822023-06-0505 June 2023 Summary of Meeting with Q & a Session to Discuss the 2022 Annual Assessment of Safety Performance at CGS ML22349A2002022-12-0101 December 2022 NRR E-mail Capture - (External_Sender) Energy Northwest Columbia Generating Station 2022 Priority Pollutant Discharge Monitoring Report ML22147A0932022-06-0606 June 2022 2021 Annual Assessment Public Meeting Summary ML22034A3932022-02-16016 February 2022 Calendar Year 2021 Security Baseline Completion Memo ML21140A3892021-05-24024 May 2021 Riv Column 1 EOC 2020 Public Meeting Summary ML20322A0362020-11-19019 November 2020 Summary of October 19, 2020, Presubmittal Teleconference with Energy Northwest Regarding Proposed COVID-19 Related Biennial Emergency Preparedness Exercise Exemption Request for Columbia Generating Station ML19053A2922019-02-20020 February 2019 Memorandum to File from P. Longmire Decommissioning Funding Plans for Columbia Generating Station ML15191A2892018-10-17017 October 2018 Response to Task Interface Agreement 2014-08 - Columbia Generating Station - Assessment of the Design and Licensing Bases for the Tower Makeup System (CAC No. MF4630; EPID L-2014-LRA-0002) ML18173A0082018-06-20020 June 2018 Cancelling Numerous Inspection Report Numbers ML16117A5552017-11-0303 November 2017 Response to Task Interface Agreement 2014-07, Columbia Generating Station Design and Licensing Basis for Containment Nitrogen Inerting System and Emergency Diesel Generator Fresh Air Intakes ML17037B8502017-02-0606 February 2017 08/21/1975 Notice of Meeting with Architect Engineers of Mark II Owners to Discuss Load Combinations and Analytical Techniques for Determining Stresses in Mechanical Components and Structures of Mark II Containments ML16230A2512016-08-0404 August 2016 Energy Northwest - Response to Volume 13- Emergency Preparedness Procedures ML16132A5122016-05-16016 May 2016 Notice Of Closed Meeting With USACE, NRC And Energy Northwest To Discuss Flood Analysis Associated With Columbia Generating Station ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML15173A2732015-06-30030 June 2015 Summary of June 4, 2015, Category 1 Public Meeting with Energy Northwest to Discussion Columbia Generating Station Seismic Hazard Reevaluation Associated with Implementation of Japan Lessons-Learned Near-Term Task Force Recommendation 2.1, ML14149A1012014-06-0202 June 2014 Notice of Forthcoming Closed Meeting to Discuss Dam Failure Analysis for Columbia Generating Station ML14148A3392014-05-30030 May 2014 G20130776/LTR-13-0866 - Memorandum to File and Transcript of 4/30/2014 Petition Review Board Conference Call with Charles Johnson, Oregon & Washington Physicians for Social Responsibility; 2.206 Petition Seismic Hazards at Columbia ML14050A3502014-02-25025 February 2014 G20130776/LTR-13-0866 - Memorandum to File and Transcript of 2/4/2014 Petition Review Board Conference Call with Charles Johnson, Oregon & Washington Physicians for Social Responsibility; 2.206 Petition Seismic Hazards at Columbia ML14087A1642013-12-12012 December 2013 Cooling Water Intake Screen NMFS Consultation No. (I/NWR/2011/05286) ML14091A2182013-12-12012 December 2013 Cooling Water Intake Screen NMFS Consultation No. (I/NWR/2011/05286) ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13098A0642013-04-10010 April 2013 Memorandum to File, Verbal Authorization on 4/6/2013 of Relief Request ISI3-13, Temporary Non-Code Repair of Reactor Water Cleanup System Piping to Prevent Reactor Shutdown Until Start of Refueling Outage 21 ML13071A4702013-02-28028 February 2013 Response to NRC Order EA-12-051-Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation ML12278A1212012-10-0404 October 2012 Notice of Pre-licensing Meeting to Discuss Future License Amendment Request to Address Impacts of Remediation Activities Undertaken by Department of Energy in the Owner-Controlled Area at Columbia Generating Station ML12102A2382012-06-13013 June 2012 Memo Conclusion of Informal Section 7 Consultation with U.S. Fish and Wildlife Service for Columbia Generating Station and Section 7 Consultation Report ML12157A2722012-06-11011 June 2012 5/31/2012 Summary of Telephone Conference with Licensees Regarding Near Term Task Force Recommendation 2.1 Seismic Reevaluations - Diablo Canyon, 1 and 2, San Onofre, Units 2 and 3, Columbia Generating Station, and Palo Verde, Units 1, 2, a ML13255A1152012-05-18018 May 2012 E-mail from B. Balsam, NRR to S. Uttal, OGC FW: Section 7 Memo ML13255A1132012-05-18018 May 2012 Memo from J. Susco, NRR to B. Holian, NRR and M. Galloway, NRR on Section 7 Consultants That Extend Beyond the Nrc'S Issuance of Renewed Operating License and ESA Section 7(D) Findings ML13255A1122012-05-17017 May 2012 Email from B. Balsam, NRR to L. Subin, OGC Et Al., on Section 7 Memo ML12101A3952012-05-0404 May 2012 Conclusion of Efh Consultation for Columbia Generating Station and Efh Consultation Report ML12058A4962012-02-27027 February 2012 License Renewal Application ML11350A0562011-12-21021 December 2011 12/15/11, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Energy Northwest, Concerning the Metal Fatigue and Operating Experience Open Items in the Columbia License Renewal Safety Evaluation Repo ML11348A0142011-12-16016 December 2011 Summary of Telephone Conference Call Held on 12/06/11, Between the U.S. Nuclear Regulatory Commission and Energy Northwest, Concerning the Metal Fatigue and Operating Experience Open Items in the Columbia License Renewal SER with Open Items ML11336A1502011-12-12012 December 2011 Summary of Telephone Conference Call Held on November 14, 2011, Between the U.S. Nuclear Regulatory Commission and Energy Northwest, Concerning the Metal Fatigue Open Item in the Columbia License Renewal Safety Evaluation Report with Open I ML11339A0872011-12-12012 December 2011 Summary of Telephone Conference Call Held on November 28, 2011, Between the U.S. Nuclear Regulatory Commission and Energy Northwest, Concerning the Upper Shelf Energy Open Item in the Columbia License Renewal Safety Evaluation Report with O ML11291A0792011-11-0101 November 2011 09/27/2011 Summary of Public Meetings Conducted to Discuss the Dseis Related to the Review of the Columbia Generating Station License Renewal Application (Tac No. ME3121) ML11273A0662011-10-0404 October 2011 Summary of the Telephone Conference Call Held on September 29, 2011, Concerning the Inspection Report Pertaining to the Columbia Generating Station, License Renewal Application ML11238A1582011-09-14014 September 2011 8/25/11 - Summary of Telephone Conference Call Between NRC and Energy Northwest Concerning Drais Pertaining to the SAMA Review of the Columbia Generating Station License Renewal Application ML11238A1202011-09-0707 September 2011 Notice of Forthcoming Meeting to Discuss the D-SEIS for the Lr of Columbia Generating Station ML11242A0942011-08-30030 August 2011 Advisory Committee on Reactor Safeguards Review of the Columbia Generating Station, License Renewal Application - Safety Evaluation Report with Open Items ML1117305512011-06-21021 June 2011 Notice of Forthcoming Pre-Licensing Meeting with Energy Northwest to Discuss Proposed Power Range Neutron Monitoring System/Arts/Mellla License Amendment Request for Columbia Generating Station ML1108714952011-04-0505 April 2011 Summary of Telephone Conference Call Held on March 23, 2011, Between NRC and Energy Northwest, Concerning the RAI Pertaining to the Columbia Generating Station, LRA (Tac No. ME3058) ML1106704962011-03-28028 March 2011 Summary of Telephone Conference Call Held on 2/28/11 Btw the USNRC and Energy Northwest Concerning Draft Requests for Additional Information Pertaining to the SAMA Review of the Columbia Generating Station License Renewal Application ML1102007102011-02-0303 February 2011 01/11/11 Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Energy Northwest Concerning the Request for Additional Information Pertaining to the Columbia Generating Station, License Renewal Applicat ML1101405882011-01-31031 January 2011 01/12/11 Summary of Telephone Conference Call Held Between NRC and Energy Northwest, Concerning the Responses to RAI Pertaining to the Columbia Generating Station. License Renewal Application ML1100604382011-01-13013 January 2011 Summary of Telephone Conference Call Held on 1/5/11, Between NRC and Energy Northwesy, Concerning the RAI Pertaining to the Columbia Generating Station License Renewal Application (Tac No. ME3058) ML1100500182011-01-0606 January 2011 Summary of Telephone Conference Call Held on January 3, 2011, Between the NRC and Energy Northwest, Concerning the Request for Additional Information Pertaining to the Columbia Generating Station, License Renewal Application (TAC Number ME3 ML1034003172010-12-14014 December 2010 Notice of Forthcoming Pre-application Meeting on 1/18/2011 with Energy Northwest to Discuss Proposed Power Range Neutron Monitoring System/Arts/Mellla License Amendment Request 2024-06-28
[Table view] |
Text
January 2, 2003 LICENSEE: Energy Northwest FACILITY: Columbia Generating Station
SUBJECT:
SUMMARY
OF MEETING HELD ON DECEMBER 12, 2002, REGARDING THE ALTERNATE SOURCE TERM SUBMITTAL On December 12, 2002, representatives of Energy Northwest met with the NRC staff to discuss problems that were experienced during the alternate source term (AST) submittal, causing its subsequent withdrawal.
Energy Northwest gave an overview of the submittal errors and discussed actions being taken to revise and later resubmit the amendment request. Errors discovered in the meteorological and main steam line break data were discussed at length. Energy Northwest discussed the revised meteorological conversion errors and revisions that have been verified. Analyses with ARCON96 were performed with the revised meteorological data.
Energy Northwest is still determining the root cause of the submittal errors. The staff asked for feedback on the root cause and Energy Northwest agreed to submit their findings to the NRC.
Energy Northwest thanked the staff for their recommendations and the opportunity to discuss the issues surrounding the submittal. At the conclusion of the meeting, the staff expressed their appreciation to Energy Northwest. An attendance list is provided in the attachment. The slides used during the meeting are available in ADAMS under accession number ML023470090.
/RA/
Brian Benney, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Managment Office of Nuclear Reactor Regulation Docket No. 50-397
Enclosure:
Meeting Attendees cc w/encl: See next page
ML030020029 Meeting Handout: ML023470090 NRC-001 OFFICE PDIV-2/PM PDIV-2/LA PDIV-2/SC NAME BBenney:rkb EPeyton SDembek DATE 12/31/02 12/24/02 12/31/02 DOCUMENT NAME: C:\ORPCheckout\FileNET\ML030020029.wpd MEETING ATTENDEES MEETING WITH ENERGY NORTHWEST REGARDING ALTERNATE SOURCE TERM SUBMITTAL DECEMBER 12, 2002 ENERGY NORTHWEST Mike Humphreys Larry Linik Bruce Boyum Douglas Coleman Marsha Eads Linda Woosley Abbas Mostala Bob Vosburg Jim Metcalf NRC Stephen Dembek Brian Benney Leta Brown Mark Blumberg Jim Bongarra Peter Hearn Ed Forrest Richard Lobel
Columbia Generating Station cc:
Mr. Rodney L. Webring (Mail Drop PE04) Mr. Dale Atkinson (Mail Drop PE08)
Vice President, Nuclear Generation Vice President, Technical Services Energy Northwest Energy Northwest P.O. Box 968 P.O. Box 968 Richland, WA 99352-0968 Richland, WA 99352-0968 Mr. Albert E. Mouncer (Mail Drop PE01) Thomas C. Poindexter, Esq.
Vice President, Corporate Services/ Winston & Strawn General Counsel/CFO 1400 L Street, N.W.
Energy Northwest Washington, DC 20005-3502 P.O. Box 968 Richland, WA 99352-0968 Mr. Bob Nichols Executive Policy Division Chairman Office of the Governor Energy Facility Site Evaluation Council P.O. Box 43113 P.O. Box 43172 Olympia, WA 98504-3113 Olympia, WA 98504-3172 Ms. Lynn Albin Mr. D. W. Coleman (Mail Drop PE20) Washington State Department of Health Manager, Performance Assessment P.O. Box 7827 and Regulatory Programs Olympia, WA 98504-7827 Energy Northwest P.O. Box 968 Mr. J. V. Parrish Richland, WA 99352-0968 Chief Executive Officer Energy Northwest Ms. Christina Perrino (Mail Drop PE20) P.O. Box 968 (Mail Drop 1023)
Manager, Licensing Richland, WA 99352-0968 Energy Northwest P.O. Box 968 Richland, WA 99352-0968 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Chairman Benton County Board of Commissioners P.O. Box 190 Prosser, WA 99350-0190 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 69 Richland, WA 99352-0069