MONTHYEARML0433703072004-12-0202 December 2004 Meeting with Firstenergy Nuclear Operating Company (Fenoc), ET Al., Regarding Beaver Valley Power Station, Units 1 and 2 (BVPS-1 and 2) Extended Power Uprate Project stage: Meeting ML0434401132005-01-0606 January 2005 Extended Power Uprate (EPU) Acceptance Review Project stage: Acceptance Review L-05-026, Supplemental Information Supporting License Amendment Request Nos. 302 and 173, Appendix a of Attachment D2005-02-23023 February 2005 Supplemental Information Supporting License Amendment Request Nos. 302 and 173, Appendix a of Attachment D Project stage: Supplement ML0506701272005-03-10010 March 2005 Notice of Meeting with Firstenergy Nuclear Operating Company, Senior Management Beaver Valley Power Station, Unit Nos. 1 and 2 Steam Generation Replacement (Unit 1 Only) and Extended Power Uprate Project stage: Meeting ML0506300622005-03-11011 March 2005 RAI, - Extended Power Uprate Project stage: RAI ML0511902682005-03-23023 March 2005 Meeting Presentation Slides - Summary of Meeting with FENOC Re Category 1, Pre-Application Review Re BVPS-1 Steam Generator (SG) Replacement and Related Alternate Source Term (AST) Approval Project stage: Meeting ML0510401672005-04-28028 April 2005 Summary of Meeting with FENOC Re Category 1, Pre-Application Review Re BVPS-1 Steam Generator (SG) Replacement and Related Alternate Source Term (AST) Approval Project stage: Meeting ML0511600692005-05-0505 May 2005 RAI, Extended Power Uprate (EPU) Project stage: RAI ML0513001472005-05-18018 May 2005 (BVPS-1 and 2) - Extended Power Uprate (EPU) Acceptance Review (TAC Nos. MC4645 and MC4646) Project stage: Acceptance Review L-05-078, Responses to a Request for Additional Information in Support of License Amendment Request Nos. 302 and 1732005-05-26026 May 2005 Responses to a Request for Additional Information in Support of License Amendment Request Nos. 302 and 173 Project stage: Request L-05-104, Probabilistic Safety Review for License Amendment Request Nos. 302 and 1732005-06-14014 June 2005 Probabilistic Safety Review for License Amendment Request Nos. 302 and 173 Project stage: Request ML0518004852005-07-19019 July 2005 (BVPS-1 and 2) - Extended Power Uprate (EPU) Acceptance Review Project stage: Acceptance Review L-05-130, Responses to a Request for Additional Information (RAI Dated June 30, 2005) in Support of License Amendment Request Nos. 302 and 1732005-07-28028 July 2005 Responses to a Request for Additional Information (RAI Dated June 30, 2005) in Support of License Amendment Request Nos. 302 and 173 Project stage: Request ML0520800052005-08-0202 August 2005 RAI, Extended Power Uprate Project stage: RAI L-05-140, Response to a Request for Additional Information (RAI Dtd August 2, 2005) in Support of License Amendment Request Nos. 302 and 173, Extended Power Uprate2005-09-0606 September 2005 Response to a Request for Additional Information (RAI Dtd August 2, 2005) in Support of License Amendment Request Nos. 302 and 173, Extended Power Uprate Project stage: Response to RAI ML0526600022005-09-30030 September 2005 RAI, Extended Power Uprate Project stage: RAI L-05-154, Supplemental Information for License Amendment Request Nos. 302 and 1732005-10-0707 October 2005 Supplemental Information for License Amendment Request Nos. 302 and 173 Project stage: Supplement L-05-168, Supplement to License Amendment Request2005-10-28028 October 2005 Supplement to License Amendment Request Project stage: Supplement ML0529700862005-11-0101 November 2005 Request for Additional Information (RAI) - Extended Power Uprate Project stage: RAI L-05-198, Supplemental Information for License Amendment Request2005-12-16016 December 2005 Supplemental Information for License Amendment Request Project stage: Supplement ML0603302622006-01-25025 January 2006 Additional Information in Support of License Amendment Request Nos. 302 and 173 Project stage: Other ML0603100312006-02-0606 February 2006 Westinghouse Electric Company, Request for Withholding Information from Public Disclosure for Beaver Valley Power Station, Unit Nos. 1 and 2 (TAC No. MC4645 and MC4646) Project stage: Withholding Request Acceptance L-06-018, Units, 1 and 2,Supplemental Response in Support of License Amendment Request Nos. 302 & 1732006-02-14014 February 2006 Units, 1 and 2,Supplemental Response in Support of License Amendment Request Nos. 302 & 173 Project stage: Supplement ML0604503032006-02-16016 February 2006 Westinghouse Electric Company, Request for Withholding Information from Public Disclosure for Beaver Valley Power Station, Unit Nos. 1 and 2 Project stage: Withholding Request Acceptance ML0604503422006-02-22022 February 2006 Westinghouse Electric Company, Request for Withholding Information from Public Disclosure Ffor Beaver Valley Power Station, Unit Nos. 1 and 2 Project stage: Withholding Request Acceptance L-06-025, Supplemental Information Pertaining to License Amendment Request No. 3022006-02-22022 February 2006 Supplemental Information Pertaining to License Amendment Request No. 302 Project stage: Supplement L-06-035, Supplemental Information - EPU Implementation Plan & Power Ascension Testing: License Amendment Request Nos. 302 and 1732006-03-10010 March 2006 Supplemental Information - EPU Implementation Plan & Power Ascension Testing: License Amendment Request Nos. 302 and 173 Project stage: Supplement ML0610004692006-05-0303 May 2006 (BVPS-1 and 2) - Draft Environmental Assessment and Finding of No Significant Impact Related to Extended Power Uprate Project stage: Draft Other L-06-083, Supplemental Information in Support of License Amendment Request Nos. 302 and 1732006-05-12012 May 2006 Supplemental Information in Support of License Amendment Request Nos. 302 and 173 Project stage: Supplement L-06-114, Additional Information in Support of License Amendment Request Nos. 302 and 1732006-07-0606 July 2006 Additional Information in Support of License Amendment Request Nos. 302 and 173 Project stage: Request ML0617706052006-07-10010 July 2006 Final Environmental Assessment and Finding of No Significant Impact Related to Proposed Extended Power Uprate Project stage: Other ML0617202482006-07-19019 July 2006 (BVPS-1 and 2) - Issuance of Amendment 8-Percent Extended Power Uprate Project stage: Approval ML0620200662006-07-19019 July 2006 Issuance of Amendment Regarding the 8-Percent Extended Power Uprate, Technical Specifications Project stage: Approval L-08-340, Transmittal of 10 CFR 50.46 Report of Changes or Errors in ECCS Evaluation Models2008-11-26026 November 2008 Transmittal of 10 CFR 50.46 Report of Changes or Errors in ECCS Evaluation Models Project stage: Request ML14210A2392014-07-31031 July 2014 Correction Letter Regarding Amendment Nos. 275 and 156 Issuance of Amendment Regarding the 8-Percent Extended Power Uprate Project stage: Approval 2005-07-28
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-23-267, Submittal of Discharge Monitoring Report (Npdes), Permit No. PA00256152023-12-18018 December 2023 Submittal of Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-229, Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports2023-11-29029 November 2023 Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports L-23-247, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-11-17017 November 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-227, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 20232023-10-20020 October 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 2023 L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA00256152023-09-14014 September 2023 Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615 L-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-179, Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-07-18018 July 2023 Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-165, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-06-26026 June 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-139, Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report2023-06-13013 June 2023 Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report L-23-055, Submittal of the Updated Final Safety Analysis Report, Revision 342023-05-23023 May 2023 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-137, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-05-18018 May 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-125, Cycle 24 Core Operating Limits Report2023-05-17017 May 2023 Cycle 24 Core Operating Limits Report L-23-132, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-10010 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-129, Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations2023-05-0505 May 2023 Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations L-23-115, Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological2023-04-27027 April 2023 Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological L-23-126, Discharge Monitoring Report (Npdes), Permit No. PA00256152023-04-22022 April 2023 Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-053, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-04-14014 April 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-058, 180-Day Steam Generator Tube Inspection Report2023-03-27027 March 2023 180-Day Steam Generator Tube Inspection Report L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-036, Report of Facility Changes, Tests and Experiments2023-03-13013 March 2023 Report of Facility Changes, Tests and Experiments L-23-086, Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0404 March 2023 Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-087, Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027)2023-03-0404 March 2023 Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027) L-23-073, Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0101 March 2023 Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-23-064, Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-02-21021 February 2023 Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-193, Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H2023-02-14014 February 2023 Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H L-22-286, Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time2023-02-14014 February 2023 Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time L-23-032, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 20222023-01-23023 January 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 2022 L-22-281, Discharge Monitoring Report (NPDES) Permit No. PA00256152022-12-16016 December 2022 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-246, Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO2022-12-0707 December 2022 Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO L-22-217, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-11-21021 November 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-226, Emergency Preparedness Plan2022-11-0404 November 2022 Emergency Preparedness Plan L-22-222, Cycle 29-1 Core Operating Limits Report2022-10-31031 October 2022 Cycle 29-1 Core Operating Limits Report L-22-228, Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2022-10-26026 October 2022 Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-22-200, Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage2022-10-21021 October 2022 Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage L-22-232, Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes2022-10-21021 October 2022 Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes L-22-238, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-10-20020 October 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-227, Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins2022-10-0303 October 2022 Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins L-22-219, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-09-26026 September 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-204, Submittal of Evacuation Time Estimates2022-09-0707 September 2022 Submittal of Evacuation Time Estimates L-22-137, Request for Fire Protection Program Changes2022-09-0606 September 2022 Request for Fire Protection Program Changes L-21-238, License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident2022-08-31031 August 2022 License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident L-22-188, Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage2022-08-22022 August 2022 Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage L-22-191, Spent Fuel Storage Cask Registration2022-08-17017 August 2022 Spent Fuel Storage Cask Registration 2023-09-14
[Table view] |
Text
FENOC FirstEnergy Nuclear Operating Cornpany James H. Lash 724-682-5234 Site Vice President Fax: 724-643-8069 May 12, 2006 L-06-083 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit Nos. 1 and 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Supplemental Information in Support of License Amendment Request Nos. 302 and 173 (Unit No. 1 TAC No. MC4645/Unit No. 2 TAC No. MC4646)
On October 4,2004, FirstEnergy Nuclear Operating Company (FENOC) submitted License Amendment Request (LAR) Nos. 302 and 173 Extended Power Uprate (EPU) by letter L-04-125 (Reference 1). During a phone call held on April 18, 2006, the NRC staff reviewers of LAR 302/173 requested that additional information be provided regarding the Effective Full Power Year (EFPY) and fluence projections associated with the EPU for Beaver Valley Power Station (BVPS) Unit No. 1 and Unit No. 2. Attachment 1 of this submittal provides the requested information discussed during the phone call.
The supplemental information provided by this transmittal has no impact on either the proposed Technical Specification changes or the no significant hazards consideration transmitted by Reference 1.
No new regulatory commitments are contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Gregory A. Dunn, Manager - FENOC Fleet Licensing, at (330) 315-7243.
I declare under penalty of perjury that the foregoing is true and correct. Executed on May I, ,2006.
Sincerely, es H. Lash
Beaver Valley Power Station, Unit Nos. 1 and 2 Supplemental Information in Support of License Amendment Request Nos. 302 and 173 (Unit No. 1 TAC No. MC4645/Unit No. 2 TAC No. MC4646)
L-06-083 Page 2 Attachments:
- 1. Summary of EFPY and Fluence Projections for BVPS-1 & BVPS-2
References:
- 1. FENOC Letter L-04-125, License Amendment Request Nos. 302 and 173, dated October 4, 2004.
c: Mr. T. G. Colburn, NRR Senior Project Manager Mr. P. C. Cataldo, NRC Senior Resident Inspector Mr. S. J. Collins, NRC Region I Administrator Mr. D. A. Allard, Director BRP/DEP Mr. L. E. Ryan (BRP/DEP)
Attachment I of L-06-083 Summary of EFPY and Fluence Projections for BVPS-1 & BVPS-2 During a phone call held on April 18, 2006, the NRC staff reviewers of License Amendment Request (LAR) 302/173, Extended Power Uprate (EPU) requested that additional information be provided regarding the Effective Full Power Year (EFPY) and fluence projections associated with the EPU for Beaver Valley Power Station (BVPS) Unit No. 1 and Unit No. 2. The following provides the requested information discussed during the phone call.
The BVPS reactor vessel fluence and EFPY projections associated with the EPU have changed over the course of time since the EPU LAR was submitted in the 2004 timeframe.
In the EPU LAR, assumptions were made that the 1.4% measurement uncertainty uprate would occur in June of 2001 followed in June of 2003 by the 8% power uprate. The actual timing of these events changed over time, with the 1.4% measurement uncertainty occurring in June of 2001 to be followed by the 8% power uprate (now projected in 2006).
This delay in implementing the 8% power uprate coupled with improved operational capacity factors and shorter outages resulted in a change in the projected EFPY associated with the End-Of-Life (EOL) for each unit.
The BVPS-1 and BVPS-2 Reactor Vessel core design history is identified in Tables I and
- 2. As noted in the tables, both BVPS-1 and BVPS-2 have been operating using a Low-Low Leakage Core (L4P) configuration over the past five cycles and it is planned that these core designs will be maintained. The cycle fluences from these core designs are identified in WCAP 15571 (Capsule Y) for BVPS-1 and WCAP 16527 for BVPS-2. In the EPU LAR, the projected EOL for BVPS-2 was 32 EFPY based on the WCAP 15675. In WCAP 16527, the Capsule X report for BVPS-2 submitted in FENOC letter (L-06-050) dated April 7, 2006, the projected EOL is 36 EFPY. The increase in the projected EOL from 32 EFPY to 36 EFPY for BVPS-2 is a result of the improved operating capacity factor and shorter outage durations experienced to date.
The tables include the capacity factor history for each unit and outage durations. In general, capacity factors for the units have improved significantly over the years, and it is projected that capacity factors and outage durations similar to those experienced over the past three to four cycles will be maintained for the remaining licensed life for each unit. As a result of these changes in the anticipated performance, BVPS-1 is projected to reach nearly 30 EFPY at EOL. The fluence value noted in the EPU LAR for BVPS-1 remains conservative based upon the current projections, and the fluence value noted in the EPU LAR for BVPS-2 remains conservative for 32 EFPY.
Sensitivity studies have been performed to determine if and when fluence management measures may be required for BVPS-1 during an extended license period. These sensitivity studies were performed because the BVPS-1 reactor vessel has historically had to address the RTpTS (Reference Temperature, Pressurized Thermal Shock) value during the period near the end of licensed life. The sensitivity analysis used the core fluences identified in WCAP 15571, adjusting the cycle fluence linearly for the projected uprate conditions. This increase coupled with expected capacity factors of between 97% and 98% and an average of 22 days per outage over the remaining licensed life of BVPS-1 would project to approximately 30 EFPY and a fluence value of approximately 3.54 E19 n/cm 2 at EOL. The projections for BVPS-1 are included in Table 3.
of L-06-083 Page 2 of 6 Table 4 identifies the WCAPs associated with the capsule evaluations and the projected fluence and RTpTs for each unit. Following the issuance of the PTS Rule, BVPS-1 evaluated various fluence management approaches. In WCAP 14543, an evaluation was presented to the NRC requesting the consideration of the use of measured fluence values rather than calculated values (reducing the effective fluence by -6.8%) and reducing the effective EOL to 27.1 EFPY resulting in an EOL RTpTS value of 264.50F. In the response to that request, the NRC issued a Safety Evaluation Report (SER) on October 7, 1997, identifying that calculated fluences are to be used and that the EOL RTpTS value would be 267.80F at 28 EFPY. At the time of these evaluations, BVPS-1 operating history appeared to support an EOL value of 28 EFPY. The Capsule Y information provided in WCAP 15571 significantly improved the projected RTpts value for BVPS-1. The value projected at 28 EFPY in WCAP 15571 (2540F) is approximately 130F better than the value projected in the SER. This improvement in the projected RTpts value allows BVPS-1 to reach EOL without concerns for encroaching on the RTpts screening limit value of 2700 F.
of L-06-083 Page 3 of 6 Table 1- (BVPS-1)
History of Capacity Factors and Outage Durations BVPS-1 Capacity Date Outage Duration Core Design Operating Factor Cycles 1 36.69 1976-1979 356 High Leakage 2 65.58 1980-1981 196 High Leakage 3 85.59 1982-1983 106 High Leakage 4 88.09 1983-1984 85 Moderate Leakage 5 87.49 1985-1986 100 Moderate Leakage 6 85.66 1986-1987 81 Moderate Leakage 7 82.92 1988-1989 116 Moderate Leakage 8 85.06 1989-1991 98 Moderate Leakage 9 81.76 1991-1993 84 Moderate Leakage 10 77.40 1993-1995 64 Low Leakage (LP) w/Hf 11 92.88 1995-1996 50 Low Leakage (L3P) w/Hf 12 82.25 1996-1997 114 Low Leakage (L3P) w/Hf 13 66.14 1998-2000 52 Low Low Leakage (L4P) 14 94.24 2000-2001 38 Low Low Leakage (L4P) 15 94.25 2001-2003 53 Low Low Leakage (L4P) 16 98.27 2003-2004 28 Low Low Leakage (L4P) 17 98.63 2004-2006 65 Low Low Leakage (L4P) of L-06-083 Page 4 of 6 Table 2 - (BVPS-2)
History of Capacity Factors and Outage Durations BVPS-2 Capacity Date Outage Core Design Operating Factor Duration Cycles 1 77.40 1987-1989 71 High Leakage 2 79.96 1989-1990 79 Low Low Leakage (L4P) 3 94.49 1990-1992 59 Moderate Leakage 4 93.43 1992-1993 81 Moderate Leakage 5 94.99 1993-1995 46 Moderate Leakage 6 95.20 1995-1996 107 Low Leakage (L3P) 7 57.93 1996-1999 44 - Low Leakage (L3P) 8 91.88 1999-2000 32 Low Low Leakage (L4P) 9 95.47 2000-2002 23 Low Low Leakage (L4P) 10 97.46 2002-2003 29 Low Low Leakage (L4P) 11 97.71 2003-2005 25 Low Low Leakage (L4P) 12 2005-2006 Low Low Leakage (L4P)
1-1 of L-06-083 Page 5 of 6 Table 3 Projected Fluence Values for Future Operating Cycles (BVPS-1)
BVPS-1 Capacity Date Outage Effective Full Fluence Factor Duration Power Years E19 n/cm2 18 98 2006-2007 22 21.02 2.48 19 98 2007-2009 22 22.41 2.64 20 98 2009-2010 22 23.81 2.81 21 98 2010-2012 22 25.20 2.97 22 98 2012-2013 22 26.60 3.13 23 98 2013-2015 22 27.99 3.30 24 98 2015-2016 22 29.39 3.46 Note: These projections are based on a variety of assumptions, which include a cycle fluence profile similar to that experienced in Cycle 10 with linear increase due to power increases, maintaining a bounding fluence of 3.54 E19 n/cm 2, and no extension of the existing license period based upon the potential for crediting the first outage duration as non-operational.
S. of L-06-083 Page 6 of 6 Table 4 WCAP's Associated with Capsule Evaluations and Projected Fluence Values (BVPS-1 & 2)
BVPS-1 WCAP Capsule Date EOL Fluence (n/cm 2) RTpts 9860 V January, 1981 32 10867 U November, 1985 32 12005 W January, 1989 - 32 4.07 E19 289 14543 W August, 1996 27.1 2.82 E19 264.5 SER October 7, 1997 28 3.02 E19 267.8 15571 Y March, 2001 28 3.54 E19 259 BVPS-2 WCAP Capsule Date EOL Fluence (n/cm2 ) RTpts 12406 U February, 1990 32 6.33 E19 14484 V March, 1996 32 3.85 E19 15675 W September, 2001 32 3.85 E19 149 16527 X April, 2006 36 4.11 E19 149