NRC INFORMATION NOTICE 2006-21:

OPERATING EXPERIENCE REGARDING

ENTRAINMENT OF AIR INTO EMERGENCY

CORE COOLING AND CONTAINMENT SPRAY

SYSTEMS

ADDRESSEES

All holders of operating licenses for nuclear power reactors, except those who have

permanently ceased operations and have certified that fuel has been permanently removed

from the reactor vessel.

PURPOSE

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice (IN) to inform

addressees of operating experience regarding possible entrainment of air into emergency core

cooling systems (ECCS) and containment spray systems (CSS), potentially affecting the

operability of these systems. The NRC expects that recipients will review the information for

applicability to their facilities and consider actions, as appropriate, to avoid similar problems.

Suggestions contained in this IN are not NRC requirements; therefore, no specific action or

written response is required.

DESCRIPTION OF CIRCUMSTANCES

Several events have occurred at nuclear power facilities involving possible entrainment of air

into ECCS and CSS piping. Air entrained in ECCS and CSS pump suction supply piping can

impact the capability of the ECCS and CSS pumps to perform their specified safety functions.

Three of these events are discussed below:

Palo Verde Nuclear Generating Station

During an NRC inspection at the Palo Verde Nuclear Generating Station, Units 1, 2, and 3 in

the fall of 2005, a problem was discovered related to potential air entrainment into the ECCS

and CSS suction header from the refueling water tank (RWT). (See NRC Inspection

Report 05000528; 529; 530/2005012, Agencywide Documents Access and Management

System (ADAMS) Accession No. ML060300193.) Specifically, the water level in the RWT could

fall below the level of the suction supply line and associated vortex breaker following the

transfer from the RWT to the containment sump after an accident. As a result, air could enter

the ECCS and CSS piping system under accident conditions. This issue was determined to be

applicable to both trains of all three units.

Following a loss-of-coolant accident (LOCA), the ECCS and CSS take suction from the RWT,

until a recirculation actuation signal (RAS) occurs and the suction supply is aligned to the

containment sump. The Palo Verde design does not include automatic closure of the RWT

isolation valves with a RAS. This design relies on sufficient fluid pressure to backseat a check

valve in the RWT supply line to stop the flow of water from the RWT.

Containment pressure analyses at Palo Verde were based on an assumed RWT temperature of

120EF. This is the maximum assumed RWT temperature allowed by technical specifications, and would be a conservative assumption for containment response calculations evaluating high

pressures. However, this assumption is nonconservative for determining the minimum

containment pressure under accident conditions.

Based on a calculation of the minimum containment pressure using the appropriate lowest

expected RWT temperature, the containment pressure was calculated to be below that

necessary to prevent air entrainment in the RWT supply. As a result, on October 11, 2005, the

licensee determined that both trains of ECCS and CSS at all three units were outside their

design bases and were declared inoperable. Operators at Units 2 and 3 entered limiting

condition of operation (LCO) 3.0.3, Unanalyzed Condition, and performed orderly shutdowns

to Mode 5. Unit 1 was already shutdown at this time for scheduled refueling outage activities.

Units 2 and 3 were later restarted following additional evaluations and other actions.

Waterford Steam Electric Station, Unit 3

During an NRC inspection at the Waterford Steam Electric Station, Unit 3 in the fall of 2004, a

problem was discovered related to potential air entrainment into the ECCS and CSS pumps.

(See NRC Inspection Reports 05000382/2004005 and 05000382/2006009; ADAMS Accession

Nos. ML050390177 and ML062420513.) Specifically, the licensee made adjustments to the

outside containment isolation valve in the line leading from the containment sump but failed to

identify if the adjustments affected the leak tightness of the valve seat. During leak testing in

September 2004, the licensee identified that the valve leaked excessively. The excessive

leakage created a condition that could potentially result in premature closure of the reactor

water storage pool (RWSP) downstream check valve, resulting in the loss of suction supply to a

train of the ECCS and CSS pumps following a medium or large break LOCA. Even without

sufficient pressure to close the RWSP downstream check valve, significant amounts of

containment air leakage through the outside containment isolation valve could result in a large

void content of the fluid entering the ECCS and CSS pumps, which could lead to failure of the

pumps.

Clinton Power Station

During an NRC inspection at the Clinton Power Station in 2005 and part of 2006, a problem

was discovered related to potential air entrainment into the high pressure core spray (HPCS)

and reactor core isolation cooling (RCIC) suction supply lines from the RCIC water storage

tank. (See NRC Inspection Report 05000461/2005002, ADAMS Accession No. ML060670370.)

Specifically, the licensee did not select an appropriate method for calculating the onset of vortexing at the intake of the HPCS and RCIC pumps suction lines from the RCIC water

storage tank. The licensees calculation did not appropriately determine the minimum height of

water above the HPCS and RCIC intake lines to preclude vortex formation. There were

nonconservative assumptions made within the calculation which did not account for the likely

presence of a fluid swirl at the intake, instead of a uniform flow field, and the change in the tank

fluid level during stroking of suction valves during realignment of pump suction sources.

DISCUSSION

The above described events highlight the importance of proper engineering analysis in ensuring

that entrained air will not enter suction supply lines and impair the ability of the ECCS and CSS

pumps to perform their specified safety functions. These events emphasize the importance of

adequately understanding how plant ECCS and CSS may be affected by plant changes and the

importance of a critical review of analysis assumptions and margins. These three events

involved different ways in which air could become entrained into the ECCS and CSS pumps, but all three had the same effect of potentially causing failure of the ECCS and CSS. The

conditions which could have allowed air to be entrained had not been revealed by routine

surveillance testing of pumping capability because it is not always practicable for the

surveillance test to replicate the accident conditions that could cause air entrainment.

Air entrained by more than a few percent by volume may degrade or cause failure of centrifugal

type pumps. A degraded pump which successfully expels small amounts of entrained air (or

other gases), may become air (or gas) bound to such a degree that it will not restart after being

stopped due to the coalescing of air into the pump casing. Additionally, voids in the pumped

fluid can cause excessive vibration and wear of important internal parts.

Relevant Generic Communications

The following previous generic communications are relevant to the issue of air (or other gas)

entrainment and its effects on ECCS and CSS performance:

NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation

during Design Basis Accidents at Pressurized-Water Reactors

NRC Information Notice 2002-18, Effect of Adding Gas Into Water Storage Tanks on the Net

Positive Suction Head for Pumps

NRC Information Notice 1998-40, Design Deficiencies Can Lead to Reduced ECCS Pump Net

Positive Suction Head During Design-Basis Accidents

NRC Information Notice 1997-38, Level-Sensing System Initiates Common-Mode Failure of

High-Pressure-Injection Pumps

NRC generic communications can be found on the NRC public Web site, http://www.nrc.gov, under Electronic Reading Room/Document Collections.

CONTACT

This information notice requires no specific action or written response. Please direct any

questions about this matter to the technical contacts listed below.

/RA by John Lubinski for/

Ho K. Nieh, Acting Director

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Technical Contacts: Charles G. Hammer, NRR/DCI

Omid Tabatabai, NRR/IOEB

301-415-2791

301-415-6616 E-mail: cgh@nrc.gov

E-mail: oty@nrc.gov

CONTACT

This information notice requires no specific action or written response. Please direct any

questions about this matter to the technical contacts listed below.

/RA by John Lubinski for/

Ho K. Nieh, Acting Director

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Technical Contacts: Charles G. Hammer, NRR/DCI

Omid Tabatabai, NRR/IOEB

301-415-2791

301-415-6616 E-mail: cgh@nrc.gov

E-mail: oty@nrc.gov

ADAMS Accession Number: ML062570468 OFFICE

IOEB:DIRS

TECH EDITOR

DCI:CPTB

IOEB:DIRS

DSS:SPWB

NAME

CPRoquecruz

HChang (by e-mail)

CHammer

OTabatabai

WLyon

DATE

09/15/2006

09/15/2006

09/18/2006

09/18/2006

9/21/06 OFFICE

PGCB:DPR

PGCB:DPR

TL:IOEB:DIR

BC:PGCB:DPR

D:DPR(A)

NAME

DBeaulieu

CHawes

ICJung

CJackson

HNieh

DATE

09/19/2006

09/20/2006

09/18/2006

9/21/2006

9/21/2006 OFFICIAL RECORD COPY