Text

-

.. .

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-456/86066(DRSS)

Docket No. 50-456 License No. NPF-59 Licensee: Commonwealth Edison Company Post Office Box 767 Chicago, IL 60690 Facility Name: Braidwood Nuclear Power Station, Unit 1 Inspection At: Braidwood, Illinois Inspection Conducted: December 11, 1986 Inspector: Kniceley li' li Oh hysical Security Inspector Date Approved By: . ed, Chief 5 eguards Section Date Inspection Summary Inspection on December 11, 1986 (Report No. 50-456/86066(DRSS))

Areas inspected: Included review of a security incident (Braidwood Security Event Report 86-12-1 dated December 5, 1986) involving a potential significant weakness in the licensee's search program. We reviewed the licensee's corrective actions both initiated and planne Results: The licensee was found to be in compliance with NRC requirements within the areas examined. The weakness was determined to be specific and randcm and not programmatic in natur PDR ADOCK 05000456 O PDR Enclosure ce,t ins SAFEGU/Gts3 i W ai%TICM Upon seperctl,e th is paga is Dec a; rolled