U. S. NUCLEAR REGULATORY COMMISSION REGIDN III Report No. 50-456/86048(DRSS)
Docket No. 50-456 License No. CPPR-132 Licensee: Commonwealth Edison Company Post Office Box 767 Chicago, IL 60690 Facility Name-Braidwood Nuclear Power Station,. Unit 1 Inspection At:
Braidwood, IL and Chicago, IL (Corporate Office)
Inspection Conducted:
September 2-5, 1986 (Site)
September 15-19,1986(Site)
September 22, 1986 (Corporate)
Date of Last Preoperational-Inspection: August 25, 1986 ic >5 h Inspectors:
. L.
ng Physical Security Inspector Date QS N J. R. Kniceley Mik Physical Secu,rity Inspector Date l[
LLh f "
/dM' MM'
G. M. Christoffer Physical Security Inspector Date
~
Approved By:
R.
reed, Chief
/C h h feguards Section Date'
Inspection Summary Inspection on September 2-5, 15-19, and 22, 1986 (Report No. 50-456/86048(DRSS))
Areas Inspected:
Included a review of the status of implementation of the licensee's physical security program required prior to fuel load licensing.
The inspection specifically addressed the following areas of the security program: Management Effectiveness; Security Program Audit; Records and Reports; Testing and Maintenance; Locks, Keys, and Combinations; Physical Barriers - Protected Area; Physical Barriers - Vital Areas; Security System Power Supply; Lighting; Compensatory Measures; Assessment Aids; Access Control - Personnel; Access Control - Packages; Access Control - Vehicles; Detection Aids - Protected Area; Detection Aids - Vital Areas; Alarm Stations; Communications; Personnel Training and Qualifications - General Requirements; and Safeguards Contingency Plan Implementation Review.
8611070217 861029 PDR ADOCK 05000456 Enclosure contains a
PDR 377.'DS INTCRIOTION c.
Lg:,a scpcration this
-
^
- -
--
Ohl LG UNlu,'d i;sf()[+,jr M Mn p:.ga is Dccontrolled t
i
_
.
_
-
.
.
.
h\\
Results: Seven of the 20 functional areas listed above were found to be
adequately implemented; the remaining 13 areas required additional inspection effort. Significant concerns were noted in the following areas:
security computer system / security alarm response; lighting /CCTV surveillance capabilities during night hours, vital area barriers, and the emergency power supply for the security system.
Details: (UNCLASSIFIED )
EneTosure contaTns SAFEGUARDS INFCRitATICN
" %-
E!"irsnaie
-
c
-