IE Insp Repts 50-324/79-38 & 50-325/79-40 on 791115-16.No Noncompliance Noted.Major Areas Inspected:Seismic Analysis for as-built safety-related Piping Sys
ML19308C646
Person / Time
Site: Brunswick  
Issue date: 12/05/1979
From: Herdt A, Modenos L, Wilcox J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19308C643 List:
References
50-324-79-38, 50-325-79-40, NUDOCS 8002010046
Download: ML19308C646 (3)


Text

-TT

.

)

>R 884

/

9'o,,

UNITED STATES E

NUCLEAR REGULATORY COMMISSION

~

o

$

E REGION 11 b[

101 MARIETTA ST., N.W., SUITE 3100 0,

%

o ATLANTA, G EORGIA 303o3 Report Nos. 50-324/79-38 and 50-325/79-40 Licensee: Carolina Power and Light Company 411 Fayetteville Street Raleigh, North Carolina 27602 Docket Nos. 50-325 and 50-324 Facility Name:

Brunswick Nuclear Plant Inspection at:

Brunswick facility near Southport, North Carolina License Nos. DPR-71 and DPR-62 Inspectors:

/f 5!' 79 L

bdenos

/

Dath Signed

'

_ _ _ -

lA 5

$

J.

'ilcox

/ /

Dat'e Signed

.

Approved by:_

/

M 2f A. R. Ierdt, Section Chief, RCES Branch Date Signed SUMMARY

Inspect ion on November 15-16, 1979 Areas Inspected This special, announced inspection involved 18 inspector-hours onsite in the areas of seismic analysis for as-built safety-related piping systems (IE Bulletin 79-14)

Results No items of noncompliance or deviations were identified.

-

8002010 0 %

ev'.

.

DETAILS 1.

Persons Contacted Licensee Employees

  • A. C. Tollison, General Manager
  • C. R. Gibson, Manager T&A
  • J. Boone, Project Engineer, NSSS
  • V. Waggoner, Engineering Supervisor Other Organizations
  • A. Gambin, Engineer, United Engineers & Co.,
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on November 16, 1979 with those persons indicated in Paragraph 1 above.

3.

Licensee Action on Previous Inspection Findings Not inspected.

4.

Unresolved Items Unresolved items were not identified during this inspection.

5.

Seismic Analysis for As-Built Safety-Related Piping Systems In response to IE Bulletin 79-14, Carolina Power and Light Company (CP&L)

submitted their response on July 23, 1979 with a subsequent letter on August 2, 1979.

In response to IE Bulletin 79-07 CP&L agreed to a total reanalysis of all safety-related piping and comparison of the as-built configurations to the as-designed (as analyzed) configurations. The re-analysis will be completed by November 19, 1979 and all modifications will be completed at the end of the next refueling outage for each unit.

The response stated that any repairs identified which are needed to maintain structural integrity or operability of a system would be fixed immediately.

~

Special Procedure 79-27 " Inspection Procedure for Seismic Supports" Rev. O dated 5/31/79 was reviewed for compliance with the requirements of IE Bulletin 79-14.

The following ISO's had been reviewed for compliance with

i

X,

~

-2-the requirements of the aforementioned Bulletin. The inspector verified that the supports on the isometrics listed below had been checked for location and as-built details:

Unit 2 RHR ISO - Sheet 1 Rev.

HPCI ISO - Sheet 17 Rev.

HPCI ISO - Sheet 10 Rev.

Unit 1 CS ISO - Sheet 26 Rev.

SWS ISO - Sheet 110 Rev. 6 Field verification of some supports in each of the following ISO's was inspected by the inspector:

Unit 2 HPCI ISO - Sheet 17 Rev.

RHR ISO - Sheet 52 Fum ISO - Sheet 1 Rev.

No items of noncompliance or deviations were identified.

.