IR 05000315/1986039
ML20214V499 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 12/01/1986 |
From: | Belanger J, Creed J, Madeda T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
To: | |
Shared Package | |
ML20214V480 | List: |
References | |
50-315-86-39, 50-316-86-39, NUDOCS 8612090709 | |
Download: ML20214V499 (1) | |
Similar Documents at Cook | |
---|---|
Category:INSPECTION REPORT
MONTHYEARIR 05000315/19990271999-10-15015 October 1999
[Table view]Partially Deleted Insp Repts 50-315/99-27 & 50-316/99-27 on 990920-24 (Ref 10CFR73.21).Noncited Violation Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant Facility. 15 IR 05000315/19980241998-12-14014 December 1998 Partially Withheld Insp Repts 50-315/98-24 & 50-316/98-24 on 981112-19 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of DC Cook Facility IR 05000315/19980111998-06-0202 June 1998 Partially Withheld Insp Repts 50-315/98-11 & 50-316/98-11 on 980504-08 (Ref 10CFR73.21(c)(2)).No Violations Noted.Major Areas Inspected:Security Program Plans,Security Program Procedures,Security Organization & Administration IR 05000315/19970191997-11-24024 November 1997 Partially Withheld Insp Repts 50-315/97-19 & 50-316/97-19 on 970929-1003 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Staff Knowledge & Performance,Training & Qualification Program & Organization & Administration IR 05000315/19970071997-04-25025 April 1997 Partially Withheld Insp Repts 50-315/97-07 & 50-316/97-07 on 970324-28 (Ref 10CFR73.21).No Violations.Major Areas Inspected:Review of Physical Security Program IR 05000315/19960081996-10-25025 October 1996 Insp Repts 50-315/96-08 & 50-316/96-08 on 960909-13.No Violations Noted.Major Areas Inspected:Licensee Assessment of Performance in Area of Physical Security IR 05000315/19930231993-12-0202 December 1993 Partially Withheld Insp Repts 50-315/93-23 & 50-316/93-23 on 931117-19 & 22-24 (Ref 10CFR73.21).No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Physical Barriers IR 05000315/19930021993-02-0505 February 1993 Partially Withheld Insp Repts 50-315/93-02 & 50-316/93-02 on 930119-22.No Violations Noted.Major Areas Inspected:Mgt Support,Protected & Vital Area Physical Barriers,Detection Sys & Detection Aid & Protected & Vital Area Access Control IR 05000315/19910111991-06-27027 June 1991 Insp Repts 50-315/91-11 & 50-316/91-11 on 910501-0614.No Violations Noted.Major Areas Inspected:Plant Operations, Reactor Trip,Maint & Surveillance,Engineering & Technical Support & Actions on Previously Identified Items IR 05000315/19900231990-11-29029 November 1990 Insp Repts 50-315/90-23 & 50-316/90-23 on 901010-901113.No Violations Noted.Major Areas Inspected:Plant Operations & Maintenance & Surveillance IR 05000315/19880181988-08-19019 August 1988 Partially Withheld Insp Repts 50-315/88-18 & 50-316/88-21 on 880705-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Mgt Effectiveness,Records & Repts,Testing & Maint, Power Supply,Lighting,Compensatory Measures & Vital Areas IR 05000315/19870421987-12-30030 December 1987 Partially Withheld Insp Repts 50-315/87-42 & 50-316/87-42 on 871207-10 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Personnel Training & Qualifications,Safeguards Contingency Plan & Compensatory Measures IR 05000206/19870141987-08-31031 August 1987 Insp Repts 50-206/87-14,50-361/87-13 & 50-362/87-15 on 870524-0704.Violations Noted.Major Areas Inspected: Operational Safety Verification,Evaluation of Plant Trips & Events,Monthly Surveillance Activities & Maint Activities IR 05000315/19870041987-03-17017 March 1987 Safety Insp Repts 50-315/87-04 & 50-316/87-04 on 870127-0223.No Violations or Deviations Noted in Five of Six Areas Inspected.Violation Re Visitor Escort Deficiency Addressed in Insp Repts 50-315/87-08 & 50-316/87-08 IR 05000315/19870081987-03-16016 March 1987 Partially Withheld Insp Repts 50-315/87-08 & 50-316/87-08 on 870127-0223 (Ref 10CFR73.21).Violation Noted:Visitor Escort Deficiency IR 05000315/19860381987-03-0303 March 1987 Addendum to Insp Repts 50-315/86-38 & 50-316/86-38,providing Criteria for Comparing Results of Capability Tests & Verification Measurements IR 05000315/19870061987-02-26026 February 1987 Insp Repts 50-315/87-06 & 50-316/87-06 on 870209-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise.Exercise Weakness Noted in Area of Protective Action Recommendations IR 05000315/19870051987-02-20020 February 1987 Insp Repts 50-315/87-05 & 50-316/87-05 on 870211-12.No Violations or Deviations Noted.Major Areas Inspected:Insp, Testing & Seal Replacement Program for Large Bore Steam Generator Snubbers IR 05000315/19870031987-02-18018 February 1987 Insp Repts 50-315/87-03 & 50-316/87-03 on 861216-870126. Violations Noted:Untimely Return to Svc Testing & Inappropriate Surveillance Test Acceptance Criteria IR 05000315/19860411987-01-16016 January 1987 Insp Repts 50-315/86-41 & 50-316/86-41 on 861104-1215. Apparent Violation Noted:Failure to Perform Timely post- Maint Operability Test on Valve & Subsequent Performance of Opposite Train Maint Being Tracked as Unresolved Issue IR 05000315/19860391986-12-0101 December 1986 Partially Withheld Physical Protection Insp Repts 50-315/86-39 & 50-316/86-39 on 861103-06 (Ref 10CFR73.21). No Violations Noted.Licensee Identified Concerns Re Personnel Access Control Program & Contingency Personnel IR 05000315/19860401986-11-28028 November 1986 Insp Repts 50-315/86-40 & 50-316/86-40 on 861103-07.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program IR 05000315/19860321986-10-17017 October 1986 Partially Withheld Reactive Physical Security Insp Repts 50-315/86-32 & 50-316/86-32 on 860818-22 & 0908-11 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected: Inadequate Maint of Safety Equipment.Details Withheld IR 05000315/19860361986-10-0101 October 1986 Insp Repts 50-315/86-36 & 50-316/86-36 on 860922-23.No Violations,Weaknesses or Deviations Noted.Major Areas Inspected:Emergency Preparedness Drill Involving Observations of Key Functions & Locations IR 05000315/19860271986-08-20020 August 1986 Insp Repts 50-315/86-27 & 50-316/86-27 on 860707-11. Violation Noted:Failure to Adequately Test ESF Response Time in Unit 1 Steam Generator Water Level hi-hi Level Turbine Trip Reactor Trip Test ML20206R9231986-06-30030 June 1986 Exam Rept 50-315/OLS-86-02 on 860519-22.Results of Exam:All Senior Reactor Operator Candidates & Seven Reactor Operator Candidates Passed IR 05000315/19860161986-06-25025 June 1986 Insp Repts 50-315/86-16 & 50-316/86-16 on 860609-11.No Noncompliance,Deviation or Deficiency Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000315/19860241986-06-20020 June 1986 Partially Withheld Physical Security Insp Repts 50-315/86-24 & 50-316/86-24 on 860604-05 (Ref 10CFR73.21).Noncompliance Noted:Items Not Searched or Secured as Required by Security Plan IR 05000315/19860211986-05-21021 May 1986 Mgt Meeting Repts 50-315/86-21 & 50-316/86-21 on 860508. Major Areas Discussed:Licensee Corrective Action Plan IR 05000315/19860031986-02-11011 February 1986 Reactive Physical Security Insp Repts 50-315/86-03 & 50-316/86-03 on 860113-16.Violations Noted:Personnel Inadequately Searched.Details Withheld (Ref 10CFR73.21) IR 05000315/19860021986-02-0606 February 1986 Insp Repts 50-315/86-02 & 50-316/86-02 on 860121-24.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Detection & Classification & Protective Action Decisionmaking IR 05000315/19850351985-12-19019 December 1985 Insp Repts 50-315/85-35 & 50-316/85-35 on 851029-1108.No Violation Identified.Major Areas Inspected:Failure of Unit 2 Reactor Trip Breaker to Actuate During Unit Trip on 851029 IR 05000315/19850381985-12-19019 December 1985 Physical Security Insp Repts 50-315/85-38 & 50-316/85-38 on 851118-21.No Violations Noted.Major Areas Inspected:Security Mgt Effectiveness,Security Organization & Security Program Audit.Details Withheld (Ref 10CFR73.21) IR 05000315/19850391985-12-0606 December 1985 Matl Control & Accounting Insp Repts 50-315/85-39 & 50-316/85-39 on 851118-21.No Noncompliance Noted.Major Areas Inspected:Reactors.Details Withheld (Ref 10CFR2.790) IR 05000315/19840211985-10-22022 October 1985 Addendum Consisting of Confirmatory Measurements Program Data Sheet to Insp Repts 50-315/84-21 & 50-316/84-23 IR 05000315/19850231985-09-0404 September 1985 Physical Protection Insp Repts 50-315/85-23 & 50-316/85-23 on 850812-15.No Noncompliance Noted.Concern for Weapons Proficiency & Adequacy of Compensatory Measures Identified. Details Withheld (Ref 10CFR73.21) IR 05000315/19850051985-08-0101 August 1985 Insp Repts 50-315/85-05 & 50-316/85-05 on 850708-12.No Violations or Deviations Noted.Major Areas Inspected: Previous Insp Findings,Lers & Independent Insp of Detector, Burnup & Crunch Computer Codes IR 05000315/19850161985-07-23023 July 1985 Insp Repts 50-315/85-16 & 50-316/85-16 on 850521-0624. Violation Noted:Failure to Follow/Comply W/Requirements of Request for tie-rod Change ML20129A0261985-07-0909 July 1985 Safeguards Insp Repts 50-315/85-18 & 50-316/85-19 on 850618- 19.Violations Noted:Failure to Adequately Control Access to Vital Areas.Details Withheld (Ref 10CFR73.21) IR 05000316/20040301985-05-31031 May 1985 Insp Repts 50-352/85-16 & 50-353/85-04 on 850316-0430. Violation Noted:Inadequate cross-discipline Review Capability in Plant Operations Review Subcommittee Reviewing Rev 2 to Procedures Re Sodium Pentaborate Analysis IR 05000316/20040111985-04-24024 April 1985 Insp Rept 50-416/85-09 on 850316-0411.Violations Noted: Steps in Sp 06-EL-1E31-M-0001 Performed Out of Sequence Resulting in ESF Containment Isolation Valve Actuation & Causing Isolation of RCIC Sys IR 05000315/19830011983-04-14014 April 1983 IE Insp Repts 50-315/83-01 & 50-316/83-01 on 830117-21 & 0217.No Noncompliance Noted.Major Areas Inspected:Qa/Qc Organization & Program Work Controls,Design Controls & Control of Contractor Activities IR 05000315/19820111982-07-14014 July 1982 IE Insp Repts 50-315/82-11 & 50-316/82-11 on 820501-0615. Noncompliance Noted:Failure to Take Adequate & Timely Corrective Actions & Failure to Maintain Functional Penetration Fire Barrier IR 05000315/19820051982-06-24024 June 1982 IE Emergency Preparedness Appraisal Repts 50-315/82-05 & 50-316/82-05 on 820315-26.Noncompliance Noted:Failure to Maintain,In State of Readiness,Adequate Interim Emergency Operations Facility IR 05000315/19820101982-06-0808 June 1982 IE Insp Repts 50-315/82-10 & 50-316/82-10 on 820314-0430. Noncompliance Noted:Failure to Follow Equipment Control Procedures When Taking Unit 2 E Centrifugal Charging Pump Out of Svc & Failure to Make Prompt Rept IR 05000315/19820091982-06-0404 June 1982 IE Insp Repts 50-315/82-09 & 50-316/82-09 on 820329-31.No Noncompliance Noted.Major Areas Inspected:Observation of Emergency Exercise Involving Integrated Response from State of Mi & Local Counties.Fema/Nrc Exercise Scenario Encl IR 05000315/19780291978-10-20020 October 1978 IE Inspec Repts 50-315/78-29 & 50-316/78-27 on 780925-29 During Which 4 Items of Noncompliance Were Noted:Security Organization,Communications Control,Detection Aids & Testing & Maintenance 1999-10-15 Category:NRC-GENERATED MONTHYEARIR 05000315/19990271999-10-15015 October 1999
[Table view]Partially Deleted Insp Repts 50-315/99-27 & 50-316/99-27 on 990920-24 (Ref 10CFR73.21).Noncited Violation Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant Facility. 15 IR 05000315/19980241998-12-14014 December 1998 Partially Withheld Insp Repts 50-315/98-24 & 50-316/98-24 on 981112-19 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of DC Cook Facility IR 05000315/19980111998-06-0202 June 1998 Partially Withheld Insp Repts 50-315/98-11 & 50-316/98-11 on 980504-08 (Ref 10CFR73.21(c)(2)).No Violations Noted.Major Areas Inspected:Security Program Plans,Security Program Procedures,Security Organization & Administration IR 05000315/19970191997-11-24024 November 1997 Partially Withheld Insp Repts 50-315/97-19 & 50-316/97-19 on 970929-1003 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Staff Knowledge & Performance,Training & Qualification Program & Organization & Administration IR 05000315/19970071997-04-25025 April 1997 Partially Withheld Insp Repts 50-315/97-07 & 50-316/97-07 on 970324-28 (Ref 10CFR73.21).No Violations.Major Areas Inspected:Review of Physical Security Program IR 05000315/19960081996-10-25025 October 1996 Insp Repts 50-315/96-08 & 50-316/96-08 on 960909-13.No Violations Noted.Major Areas Inspected:Licensee Assessment of Performance in Area of Physical Security IR 05000315/19930231993-12-0202 December 1993 Partially Withheld Insp Repts 50-315/93-23 & 50-316/93-23 on 931117-19 & 22-24 (Ref 10CFR73.21).No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Physical Barriers IR 05000315/19930021993-02-0505 February 1993 Partially Withheld Insp Repts 50-315/93-02 & 50-316/93-02 on 930119-22.No Violations Noted.Major Areas Inspected:Mgt Support,Protected & Vital Area Physical Barriers,Detection Sys & Detection Aid & Protected & Vital Area Access Control IR 05000315/19910111991-06-27027 June 1991 Insp Repts 50-315/91-11 & 50-316/91-11 on 910501-0614.No Violations Noted.Major Areas Inspected:Plant Operations, Reactor Trip,Maint & Surveillance,Engineering & Technical Support & Actions on Previously Identified Items IR 05000315/19900231990-11-29029 November 1990 Insp Repts 50-315/90-23 & 50-316/90-23 on 901010-901113.No Violations Noted.Major Areas Inspected:Plant Operations & Maintenance & Surveillance IR 05000315/19880181988-08-19019 August 1988 Partially Withheld Insp Repts 50-315/88-18 & 50-316/88-21 on 880705-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Mgt Effectiveness,Records & Repts,Testing & Maint, Power Supply,Lighting,Compensatory Measures & Vital Areas IR 05000315/19870421987-12-30030 December 1987 Partially Withheld Insp Repts 50-315/87-42 & 50-316/87-42 on 871207-10 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Personnel Training & Qualifications,Safeguards Contingency Plan & Compensatory Measures IR 05000206/19870141987-08-31031 August 1987 Insp Repts 50-206/87-14,50-361/87-13 & 50-362/87-15 on 870524-0704.Violations Noted.Major Areas Inspected: Operational Safety Verification,Evaluation of Plant Trips & Events,Monthly Surveillance Activities & Maint Activities IR 05000315/19870041987-03-17017 March 1987 Safety Insp Repts 50-315/87-04 & 50-316/87-04 on 870127-0223.No Violations or Deviations Noted in Five of Six Areas Inspected.Violation Re Visitor Escort Deficiency Addressed in Insp Repts 50-315/87-08 & 50-316/87-08 IR 05000315/19870081987-03-16016 March 1987 Partially Withheld Insp Repts 50-315/87-08 & 50-316/87-08 on 870127-0223 (Ref 10CFR73.21).Violation Noted:Visitor Escort Deficiency IR 05000315/19860381987-03-0303 March 1987 Addendum to Insp Repts 50-315/86-38 & 50-316/86-38,providing Criteria for Comparing Results of Capability Tests & Verification Measurements IR 05000315/19870061987-02-26026 February 1987 Insp Repts 50-315/87-06 & 50-316/87-06 on 870209-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise.Exercise Weakness Noted in Area of Protective Action Recommendations IR 05000315/19870051987-02-20020 February 1987 Insp Repts 50-315/87-05 & 50-316/87-05 on 870211-12.No Violations or Deviations Noted.Major Areas Inspected:Insp, Testing & Seal Replacement Program for Large Bore Steam Generator Snubbers IR 05000315/19870031987-02-18018 February 1987 Insp Repts 50-315/87-03 & 50-316/87-03 on 861216-870126. Violations Noted:Untimely Return to Svc Testing & Inappropriate Surveillance Test Acceptance Criteria IR 05000315/19860411987-01-16016 January 1987 Insp Repts 50-315/86-41 & 50-316/86-41 on 861104-1215. Apparent Violation Noted:Failure to Perform Timely post- Maint Operability Test on Valve & Subsequent Performance of Opposite Train Maint Being Tracked as Unresolved Issue IR 05000315/19860391986-12-0101 December 1986 Partially Withheld Physical Protection Insp Repts 50-315/86-39 & 50-316/86-39 on 861103-06 (Ref 10CFR73.21). No Violations Noted.Licensee Identified Concerns Re Personnel Access Control Program & Contingency Personnel IR 05000315/19860401986-11-28028 November 1986 Insp Repts 50-315/86-40 & 50-316/86-40 on 861103-07.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program IR 05000315/19860321986-10-17017 October 1986 Partially Withheld Reactive Physical Security Insp Repts 50-315/86-32 & 50-316/86-32 on 860818-22 & 0908-11 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected: Inadequate Maint of Safety Equipment.Details Withheld IR 05000315/19860361986-10-0101 October 1986 Insp Repts 50-315/86-36 & 50-316/86-36 on 860922-23.No Violations,Weaknesses or Deviations Noted.Major Areas Inspected:Emergency Preparedness Drill Involving Observations of Key Functions & Locations IR 05000315/19860271986-08-20020 August 1986 Insp Repts 50-315/86-27 & 50-316/86-27 on 860707-11. Violation Noted:Failure to Adequately Test ESF Response Time in Unit 1 Steam Generator Water Level hi-hi Level Turbine Trip Reactor Trip Test ML20206R9231986-06-30030 June 1986 Exam Rept 50-315/OLS-86-02 on 860519-22.Results of Exam:All Senior Reactor Operator Candidates & Seven Reactor Operator Candidates Passed IR 05000315/19860161986-06-25025 June 1986 Insp Repts 50-315/86-16 & 50-316/86-16 on 860609-11.No Noncompliance,Deviation or Deficiency Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000315/19860241986-06-20020 June 1986 Partially Withheld Physical Security Insp Repts 50-315/86-24 & 50-316/86-24 on 860604-05 (Ref 10CFR73.21).Noncompliance Noted:Items Not Searched or Secured as Required by Security Plan IR 05000315/19860211986-05-21021 May 1986 Mgt Meeting Repts 50-315/86-21 & 50-316/86-21 on 860508. Major Areas Discussed:Licensee Corrective Action Plan IR 05000315/19860031986-02-11011 February 1986 Reactive Physical Security Insp Repts 50-315/86-03 & 50-316/86-03 on 860113-16.Violations Noted:Personnel Inadequately Searched.Details Withheld (Ref 10CFR73.21) IR 05000315/19860021986-02-0606 February 1986 Insp Repts 50-315/86-02 & 50-316/86-02 on 860121-24.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Detection & Classification & Protective Action Decisionmaking IR 05000315/19850351985-12-19019 December 1985 Insp Repts 50-315/85-35 & 50-316/85-35 on 851029-1108.No Violation Identified.Major Areas Inspected:Failure of Unit 2 Reactor Trip Breaker to Actuate During Unit Trip on 851029 IR 05000315/19850381985-12-19019 December 1985 Physical Security Insp Repts 50-315/85-38 & 50-316/85-38 on 851118-21.No Violations Noted.Major Areas Inspected:Security Mgt Effectiveness,Security Organization & Security Program Audit.Details Withheld (Ref 10CFR73.21) IR 05000315/19850391985-12-0606 December 1985 Matl Control & Accounting Insp Repts 50-315/85-39 & 50-316/85-39 on 851118-21.No Noncompliance Noted.Major Areas Inspected:Reactors.Details Withheld (Ref 10CFR2.790) IR 05000315/19840211985-10-22022 October 1985 Addendum Consisting of Confirmatory Measurements Program Data Sheet to Insp Repts 50-315/84-21 & 50-316/84-23 IR 05000315/19850231985-09-0404 September 1985 Physical Protection Insp Repts 50-315/85-23 & 50-316/85-23 on 850812-15.No Noncompliance Noted.Concern for Weapons Proficiency & Adequacy of Compensatory Measures Identified. Details Withheld (Ref 10CFR73.21) IR 05000315/19850051985-08-0101 August 1985 Insp Repts 50-315/85-05 & 50-316/85-05 on 850708-12.No Violations or Deviations Noted.Major Areas Inspected: Previous Insp Findings,Lers & Independent Insp of Detector, Burnup & Crunch Computer Codes IR 05000315/19850161985-07-23023 July 1985 Insp Repts 50-315/85-16 & 50-316/85-16 on 850521-0624. Violation Noted:Failure to Follow/Comply W/Requirements of Request for tie-rod Change ML20129A0261985-07-0909 July 1985 Safeguards Insp Repts 50-315/85-18 & 50-316/85-19 on 850618- 19.Violations Noted:Failure to Adequately Control Access to Vital Areas.Details Withheld (Ref 10CFR73.21) IR 05000316/20040301985-05-31031 May 1985 Insp Repts 50-352/85-16 & 50-353/85-04 on 850316-0430. Violation Noted:Inadequate cross-discipline Review Capability in Plant Operations Review Subcommittee Reviewing Rev 2 to Procedures Re Sodium Pentaborate Analysis IR 05000316/20040111985-04-24024 April 1985 Insp Rept 50-416/85-09 on 850316-0411.Violations Noted: Steps in Sp 06-EL-1E31-M-0001 Performed Out of Sequence Resulting in ESF Containment Isolation Valve Actuation & Causing Isolation of RCIC Sys IR 05000315/19830011983-04-14014 April 1983 IE Insp Repts 50-315/83-01 & 50-316/83-01 on 830117-21 & 0217.No Noncompliance Noted.Major Areas Inspected:Qa/Qc Organization & Program Work Controls,Design Controls & Control of Contractor Activities IR 05000315/19820111982-07-14014 July 1982 IE Insp Repts 50-315/82-11 & 50-316/82-11 on 820501-0615. Noncompliance Noted:Failure to Take Adequate & Timely Corrective Actions & Failure to Maintain Functional Penetration Fire Barrier IR 05000315/19820051982-06-24024 June 1982 IE Emergency Preparedness Appraisal Repts 50-315/82-05 & 50-316/82-05 on 820315-26.Noncompliance Noted:Failure to Maintain,In State of Readiness,Adequate Interim Emergency Operations Facility IR 05000315/19820101982-06-0808 June 1982 IE Insp Repts 50-315/82-10 & 50-316/82-10 on 820314-0430. Noncompliance Noted:Failure to Follow Equipment Control Procedures When Taking Unit 2 E Centrifugal Charging Pump Out of Svc & Failure to Make Prompt Rept IR 05000315/19820091982-06-0404 June 1982 IE Insp Repts 50-315/82-09 & 50-316/82-09 on 820329-31.No Noncompliance Noted.Major Areas Inspected:Observation of Emergency Exercise Involving Integrated Response from State of Mi & Local Counties.Fema/Nrc Exercise Scenario Encl IR 05000315/19780291978-10-20020 October 1978 IE Inspec Repts 50-315/78-29 & 50-316/78-27 on 780925-29 During Which 4 Items of Noncompliance Were Noted:Security Organization,Communications Control,Detection Aids & Testing & Maintenance 1999-10-15 Category:INSPECTION REPORT MONTHYEARIR 05000315/19990271999-10-15015 October 1999
[Table view]Partially Deleted Insp Repts 50-315/99-27 & 50-316/99-27 on 990920-24 (Ref 10CFR73.21).Noncited Violation Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant Facility. 15 IR 05000315/19980241998-12-14014 December 1998 Partially Withheld Insp Repts 50-315/98-24 & 50-316/98-24 on 981112-19 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of DC Cook Facility IR 05000315/19980111998-06-0202 June 1998 Partially Withheld Insp Repts 50-315/98-11 & 50-316/98-11 on 980504-08 (Ref 10CFR73.21(c)(2)).No Violations Noted.Major Areas Inspected:Security Program Plans,Security Program Procedures,Security Organization & Administration IR 05000315/19970191997-11-24024 November 1997 Partially Withheld Insp Repts 50-315/97-19 & 50-316/97-19 on 970929-1003 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Staff Knowledge & Performance,Training & Qualification Program & Organization & Administration IR 05000315/19970071997-04-25025 April 1997 Partially Withheld Insp Repts 50-315/97-07 & 50-316/97-07 on 970324-28 (Ref 10CFR73.21).No Violations.Major Areas Inspected:Review of Physical Security Program IR 05000315/19960081996-10-25025 October 1996 Insp Repts 50-315/96-08 & 50-316/96-08 on 960909-13.No Violations Noted.Major Areas Inspected:Licensee Assessment of Performance in Area of Physical Security IR 05000315/19930231993-12-0202 December 1993 Partially Withheld Insp Repts 50-315/93-23 & 50-316/93-23 on 931117-19 & 22-24 (Ref 10CFR73.21).No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Physical Barriers IR 05000315/19930021993-02-0505 February 1993 Partially Withheld Insp Repts 50-315/93-02 & 50-316/93-02 on 930119-22.No Violations Noted.Major Areas Inspected:Mgt Support,Protected & Vital Area Physical Barriers,Detection Sys & Detection Aid & Protected & Vital Area Access Control IR 05000315/19910111991-06-27027 June 1991 Insp Repts 50-315/91-11 & 50-316/91-11 on 910501-0614.No Violations Noted.Major Areas Inspected:Plant Operations, Reactor Trip,Maint & Surveillance,Engineering & Technical Support & Actions on Previously Identified Items IR 05000315/19900231990-11-29029 November 1990 Insp Repts 50-315/90-23 & 50-316/90-23 on 901010-901113.No Violations Noted.Major Areas Inspected:Plant Operations & Maintenance & Surveillance IR 05000315/19880181988-08-19019 August 1988 Partially Withheld Insp Repts 50-315/88-18 & 50-316/88-21 on 880705-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Mgt Effectiveness,Records & Repts,Testing & Maint, Power Supply,Lighting,Compensatory Measures & Vital Areas IR 05000315/19870421987-12-30030 December 1987 Partially Withheld Insp Repts 50-315/87-42 & 50-316/87-42 on 871207-10 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Personnel Training & Qualifications,Safeguards Contingency Plan & Compensatory Measures IR 05000206/19870141987-08-31031 August 1987 Insp Repts 50-206/87-14,50-361/87-13 & 50-362/87-15 on 870524-0704.Violations Noted.Major Areas Inspected: Operational Safety Verification,Evaluation of Plant Trips & Events,Monthly Surveillance Activities & Maint Activities IR 05000315/19870041987-03-17017 March 1987 Safety Insp Repts 50-315/87-04 & 50-316/87-04 on 870127-0223.No Violations or Deviations Noted in Five of Six Areas Inspected.Violation Re Visitor Escort Deficiency Addressed in Insp Repts 50-315/87-08 & 50-316/87-08 IR 05000315/19870081987-03-16016 March 1987 Partially Withheld Insp Repts 50-315/87-08 & 50-316/87-08 on 870127-0223 (Ref 10CFR73.21).Violation Noted:Visitor Escort Deficiency IR 05000315/19860381987-03-0303 March 1987 Addendum to Insp Repts 50-315/86-38 & 50-316/86-38,providing Criteria for Comparing Results of Capability Tests & Verification Measurements IR 05000315/19870061987-02-26026 February 1987 Insp Repts 50-315/87-06 & 50-316/87-06 on 870209-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise.Exercise Weakness Noted in Area of Protective Action Recommendations IR 05000315/19870051987-02-20020 February 1987 Insp Repts 50-315/87-05 & 50-316/87-05 on 870211-12.No Violations or Deviations Noted.Major Areas Inspected:Insp, Testing & Seal Replacement Program for Large Bore Steam Generator Snubbers IR 05000315/19870031987-02-18018 February 1987 Insp Repts 50-315/87-03 & 50-316/87-03 on 861216-870126. Violations Noted:Untimely Return to Svc Testing & Inappropriate Surveillance Test Acceptance Criteria IR 05000315/19860411987-01-16016 January 1987 Insp Repts 50-315/86-41 & 50-316/86-41 on 861104-1215. Apparent Violation Noted:Failure to Perform Timely post- Maint Operability Test on Valve & Subsequent Performance of Opposite Train Maint Being Tracked as Unresolved Issue IR 05000315/19860391986-12-0101 December 1986 Partially Withheld Physical Protection Insp Repts 50-315/86-39 & 50-316/86-39 on 861103-06 (Ref 10CFR73.21). No Violations Noted.Licensee Identified Concerns Re Personnel Access Control Program & Contingency Personnel IR 05000315/19860401986-11-28028 November 1986 Insp Repts 50-315/86-40 & 50-316/86-40 on 861103-07.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program IR 05000315/19860321986-10-17017 October 1986 Partially Withheld Reactive Physical Security Insp Repts 50-315/86-32 & 50-316/86-32 on 860818-22 & 0908-11 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected: Inadequate Maint of Safety Equipment.Details Withheld IR 05000315/19860361986-10-0101 October 1986 Insp Repts 50-315/86-36 & 50-316/86-36 on 860922-23.No Violations,Weaknesses or Deviations Noted.Major Areas Inspected:Emergency Preparedness Drill Involving Observations of Key Functions & Locations IR 05000315/19860271986-08-20020 August 1986 Insp Repts 50-315/86-27 & 50-316/86-27 on 860707-11. Violation Noted:Failure to Adequately Test ESF Response Time in Unit 1 Steam Generator Water Level hi-hi Level Turbine Trip Reactor Trip Test ML20206R9231986-06-30030 June 1986 Exam Rept 50-315/OLS-86-02 on 860519-22.Results of Exam:All Senior Reactor Operator Candidates & Seven Reactor Operator Candidates Passed IR 05000315/19860161986-06-25025 June 1986 Insp Repts 50-315/86-16 & 50-316/86-16 on 860609-11.No Noncompliance,Deviation or Deficiency Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000315/19860241986-06-20020 June 1986 Partially Withheld Physical Security Insp Repts 50-315/86-24 & 50-316/86-24 on 860604-05 (Ref 10CFR73.21).Noncompliance Noted:Items Not Searched or Secured as Required by Security Plan IR 05000315/19860211986-05-21021 May 1986 Mgt Meeting Repts 50-315/86-21 & 50-316/86-21 on 860508. Major Areas Discussed:Licensee Corrective Action Plan IR 05000315/19860031986-02-11011 February 1986 Reactive Physical Security Insp Repts 50-315/86-03 & 50-316/86-03 on 860113-16.Violations Noted:Personnel Inadequately Searched.Details Withheld (Ref 10CFR73.21) IR 05000315/19860021986-02-0606 February 1986 Insp Repts 50-315/86-02 & 50-316/86-02 on 860121-24.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Detection & Classification & Protective Action Decisionmaking IR 05000315/19850351985-12-19019 December 1985 Insp Repts 50-315/85-35 & 50-316/85-35 on 851029-1108.No Violation Identified.Major Areas Inspected:Failure of Unit 2 Reactor Trip Breaker to Actuate During Unit Trip on 851029 IR 05000315/19850381985-12-19019 December 1985 Physical Security Insp Repts 50-315/85-38 & 50-316/85-38 on 851118-21.No Violations Noted.Major Areas Inspected:Security Mgt Effectiveness,Security Organization & Security Program Audit.Details Withheld (Ref 10CFR73.21) IR 05000315/19850391985-12-0606 December 1985 Matl Control & Accounting Insp Repts 50-315/85-39 & 50-316/85-39 on 851118-21.No Noncompliance Noted.Major Areas Inspected:Reactors.Details Withheld (Ref 10CFR2.790) IR 05000315/19840211985-10-22022 October 1985 Addendum Consisting of Confirmatory Measurements Program Data Sheet to Insp Repts 50-315/84-21 & 50-316/84-23 IR 05000315/19850231985-09-0404 September 1985 Physical Protection Insp Repts 50-315/85-23 & 50-316/85-23 on 850812-15.No Noncompliance Noted.Concern for Weapons Proficiency & Adequacy of Compensatory Measures Identified. Details Withheld (Ref 10CFR73.21) IR 05000315/19850051985-08-0101 August 1985 Insp Repts 50-315/85-05 & 50-316/85-05 on 850708-12.No Violations or Deviations Noted.Major Areas Inspected: Previous Insp Findings,Lers & Independent Insp of Detector, Burnup & Crunch Computer Codes IR 05000315/19850161985-07-23023 July 1985 Insp Repts 50-315/85-16 & 50-316/85-16 on 850521-0624. Violation Noted:Failure to Follow/Comply W/Requirements of Request for tie-rod Change ML20129A0261985-07-0909 July 1985 Safeguards Insp Repts 50-315/85-18 & 50-316/85-19 on 850618- 19.Violations Noted:Failure to Adequately Control Access to Vital Areas.Details Withheld (Ref 10CFR73.21) IR 05000316/20040301985-05-31031 May 1985 Insp Repts 50-352/85-16 & 50-353/85-04 on 850316-0430. Violation Noted:Inadequate cross-discipline Review Capability in Plant Operations Review Subcommittee Reviewing Rev 2 to Procedures Re Sodium Pentaborate Analysis IR 05000316/20040111985-04-24024 April 1985 Insp Rept 50-416/85-09 on 850316-0411.Violations Noted: Steps in Sp 06-EL-1E31-M-0001 Performed Out of Sequence Resulting in ESF Containment Isolation Valve Actuation & Causing Isolation of RCIC Sys IR 05000315/19830011983-04-14014 April 1983 IE Insp Repts 50-315/83-01 & 50-316/83-01 on 830117-21 & 0217.No Noncompliance Noted.Major Areas Inspected:Qa/Qc Organization & Program Work Controls,Design Controls & Control of Contractor Activities IR 05000315/19820111982-07-14014 July 1982 IE Insp Repts 50-315/82-11 & 50-316/82-11 on 820501-0615. Noncompliance Noted:Failure to Take Adequate & Timely Corrective Actions & Failure to Maintain Functional Penetration Fire Barrier IR 05000315/19820051982-06-24024 June 1982 IE Emergency Preparedness Appraisal Repts 50-315/82-05 & 50-316/82-05 on 820315-26.Noncompliance Noted:Failure to Maintain,In State of Readiness,Adequate Interim Emergency Operations Facility IR 05000315/19820101982-06-0808 June 1982 IE Insp Repts 50-315/82-10 & 50-316/82-10 on 820314-0430. Noncompliance Noted:Failure to Follow Equipment Control Procedures When Taking Unit 2 E Centrifugal Charging Pump Out of Svc & Failure to Make Prompt Rept IR 05000315/19820091982-06-0404 June 1982 IE Insp Repts 50-315/82-09 & 50-316/82-09 on 820329-31.No Noncompliance Noted.Major Areas Inspected:Observation of Emergency Exercise Involving Integrated Response from State of Mi & Local Counties.Fema/Nrc Exercise Scenario Encl IR 05000315/19780291978-10-20020 October 1978 IE Inspec Repts 50-315/78-29 & 50-316/78-27 on 780925-29 During Which 4 Items of Noncompliance Were Noted:Security Organization,Communications Control,Detection Aids & Testing & Maintenance 1999-10-15 Category:UTILITY MONTHYEARIR 05000315/19880181988-08-19019 August 1988
[Table view]Partially Withheld Insp Repts 50-315/88-18 & 50-316/88-21 on 880705-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Mgt Effectiveness,Records & Repts,Testing & Maint, Power Supply,Lighting,Compensatory Measures & Vital Areas IR 05000315/19870421987-12-30030 December 1987 Partially Withheld Insp Repts 50-315/87-42 & 50-316/87-42 on 871207-10 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Personnel Training & Qualifications,Safeguards Contingency Plan & Compensatory Measures IR 05000206/19870141987-08-31031 August 1987 Insp Repts 50-206/87-14,50-361/87-13 & 50-362/87-15 on 870524-0704.Violations Noted.Major Areas Inspected: Operational Safety Verification,Evaluation of Plant Trips & Events,Monthly Surveillance Activities & Maint Activities IR 05000315/19870041987-03-17017 March 1987 Safety Insp Repts 50-315/87-04 & 50-316/87-04 on 870127-0223.No Violations or Deviations Noted in Five of Six Areas Inspected.Violation Re Visitor Escort Deficiency Addressed in Insp Repts 50-315/87-08 & 50-316/87-08 IR 05000315/19870081987-03-16016 March 1987 Partially Withheld Insp Repts 50-315/87-08 & 50-316/87-08 on 870127-0223 (Ref 10CFR73.21).Violation Noted:Visitor Escort Deficiency IR 05000315/19860381987-03-0303 March 1987 Addendum to Insp Repts 50-315/86-38 & 50-316/86-38,providing Criteria for Comparing Results of Capability Tests & Verification Measurements IR 05000315/19870061987-02-26026 February 1987 Insp Repts 50-315/87-06 & 50-316/87-06 on 870209-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise.Exercise Weakness Noted in Area of Protective Action Recommendations IR 05000315/19870051987-02-20020 February 1987 Insp Repts 50-315/87-05 & 50-316/87-05 on 870211-12.No Violations or Deviations Noted.Major Areas Inspected:Insp, Testing & Seal Replacement Program for Large Bore Steam Generator Snubbers IR 05000315/19870031987-02-18018 February 1987 Insp Repts 50-315/87-03 & 50-316/87-03 on 861216-870126. Violations Noted:Untimely Return to Svc Testing & Inappropriate Surveillance Test Acceptance Criteria IR 05000315/19860411987-01-16016 January 1987 Insp Repts 50-315/86-41 & 50-316/86-41 on 861104-1215. Apparent Violation Noted:Failure to Perform Timely post- Maint Operability Test on Valve & Subsequent Performance of Opposite Train Maint Being Tracked as Unresolved Issue IR 05000315/19860391986-12-0101 December 1986 Partially Withheld Physical Protection Insp Repts 50-315/86-39 & 50-316/86-39 on 861103-06 (Ref 10CFR73.21). No Violations Noted.Licensee Identified Concerns Re Personnel Access Control Program & Contingency Personnel IR 05000315/19860401986-11-28028 November 1986 Insp Repts 50-315/86-40 & 50-316/86-40 on 861103-07.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program IR 05000315/19860361986-10-0101 October 1986 Insp Repts 50-315/86-36 & 50-316/86-36 on 860922-23.No Violations,Weaknesses or Deviations Noted.Major Areas Inspected:Emergency Preparedness Drill Involving Observations of Key Functions & Locations IR 05000315/19860271986-08-20020 August 1986 Insp Repts 50-315/86-27 & 50-316/86-27 on 860707-11. Violation Noted:Failure to Adequately Test ESF Response Time in Unit 1 Steam Generator Water Level hi-hi Level Turbine Trip Reactor Trip Test ML20206R9231986-06-30030 June 1986 Exam Rept 50-315/OLS-86-02 on 860519-22.Results of Exam:All Senior Reactor Operator Candidates & Seven Reactor Operator Candidates Passed IR 05000315/19860161986-06-25025 June 1986 Insp Repts 50-315/86-16 & 50-316/86-16 on 860609-11.No Noncompliance,Deviation or Deficiency Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000315/19860241986-06-20020 June 1986 Partially Withheld Physical Security Insp Repts 50-315/86-24 & 50-316/86-24 on 860604-05 (Ref 10CFR73.21).Noncompliance Noted:Items Not Searched or Secured as Required by Security Plan IR 05000315/19860211986-05-21021 May 1986 Mgt Meeting Repts 50-315/86-21 & 50-316/86-21 on 860508. Major Areas Discussed:Licensee Corrective Action Plan IR 05000315/19860031986-02-11011 February 1986 Reactive Physical Security Insp Repts 50-315/86-03 & 50-316/86-03 on 860113-16.Violations Noted:Personnel Inadequately Searched.Details Withheld (Ref 10CFR73.21) IR 05000315/19860021986-02-0606 February 1986 Insp Repts 50-315/86-02 & 50-316/86-02 on 860121-24.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Detection & Classification & Protective Action Decisionmaking IR 05000315/19850351985-12-19019 December 1985 Insp Repts 50-315/85-35 & 50-316/85-35 on 851029-1108.No Violation Identified.Major Areas Inspected:Failure of Unit 2 Reactor Trip Breaker to Actuate During Unit Trip on 851029 IR 05000315/19850381985-12-19019 December 1985 Physical Security Insp Repts 50-315/85-38 & 50-316/85-38 on 851118-21.No Violations Noted.Major Areas Inspected:Security Mgt Effectiveness,Security Organization & Security Program Audit.Details Withheld (Ref 10CFR73.21) IR 05000315/19850391985-12-0606 December 1985 Matl Control & Accounting Insp Repts 50-315/85-39 & 50-316/85-39 on 851118-21.No Noncompliance Noted.Major Areas Inspected:Reactors.Details Withheld (Ref 10CFR2.790) IR 05000315/19840211985-10-22022 October 1985 Addendum Consisting of Confirmatory Measurements Program Data Sheet to Insp Repts 50-315/84-21 & 50-316/84-23 IR 05000315/19850231985-09-0404 September 1985 Physical Protection Insp Repts 50-315/85-23 & 50-316/85-23 on 850812-15.No Noncompliance Noted.Concern for Weapons Proficiency & Adequacy of Compensatory Measures Identified. Details Withheld (Ref 10CFR73.21) IR 05000315/19850051985-08-0101 August 1985 Insp Repts 50-315/85-05 & 50-316/85-05 on 850708-12.No Violations or Deviations Noted.Major Areas Inspected: Previous Insp Findings,Lers & Independent Insp of Detector, Burnup & Crunch Computer Codes IR 05000315/19850161985-07-23023 July 1985 Insp Repts 50-315/85-16 & 50-316/85-16 on 850521-0624. Violation Noted:Failure to Follow/Comply W/Requirements of Request for tie-rod Change ML20129A0261985-07-0909 July 1985 Safeguards Insp Repts 50-315/85-18 & 50-316/85-19 on 850618- 19.Violations Noted:Failure to Adequately Control Access to Vital Areas.Details Withheld (Ref 10CFR73.21) IR 05000316/20040301985-05-31031 May 1985 Insp Repts 50-352/85-16 & 50-353/85-04 on 850316-0430. Violation Noted:Inadequate cross-discipline Review Capability in Plant Operations Review Subcommittee Reviewing Rev 2 to Procedures Re Sodium Pentaborate Analysis IR 05000316/20040111985-04-24024 April 1985 Insp Rept 50-416/85-09 on 850316-0411.Violations Noted: Steps in Sp 06-EL-1E31-M-0001 Performed Out of Sequence Resulting in ESF Containment Isolation Valve Actuation & Causing Isolation of RCIC Sys IR 05000315/19830011983-04-14014 April 1983 IE Insp Repts 50-315/83-01 & 50-316/83-01 on 830117-21 & 0217.No Noncompliance Noted.Major Areas Inspected:Qa/Qc Organization & Program Work Controls,Design Controls & Control of Contractor Activities IR 05000315/19820111982-07-14014 July 1982 IE Insp Repts 50-315/82-11 & 50-316/82-11 on 820501-0615. Noncompliance Noted:Failure to Take Adequate & Timely Corrective Actions & Failure to Maintain Functional Penetration Fire Barrier IR 05000315/19820051982-06-24024 June 1982 IE Emergency Preparedness Appraisal Repts 50-315/82-05 & 50-316/82-05 on 820315-26.Noncompliance Noted:Failure to Maintain,In State of Readiness,Adequate Interim Emergency Operations Facility IR 05000315/19820101982-06-0808 June 1982 IE Insp Repts 50-315/82-10 & 50-316/82-10 on 820314-0430. Noncompliance Noted:Failure to Follow Equipment Control Procedures When Taking Unit 2 E Centrifugal Charging Pump Out of Svc & Failure to Make Prompt Rept IR 05000315/19820091982-06-0404 June 1982 IE Insp Repts 50-315/82-09 & 50-316/82-09 on 820329-31.No Noncompliance Noted.Major Areas Inspected:Observation of Emergency Exercise Involving Integrated Response from State of Mi & Local Counties.Fema/Nrc Exercise Scenario Encl IR 05000315/19780291978-10-20020 October 1978 IE Inspec Repts 50-315/78-29 & 50-316/78-27 on 780925-29 During Which 4 Items of Noncompliance Were Noted:Security Organization,Communications Control,Detection Aids & Testing & Maintenance 1988-08-19 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000315/19990271999-10-15015 October 1999
[Table view]Partially Deleted Insp Repts 50-315/99-27 & 50-316/99-27 on 990920-24 (Ref 10CFR73.21).Noncited Violation Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Plant Facility. 15 IR 05000315/19980241998-12-14014 December 1998 Partially Withheld Insp Repts 50-315/98-24 & 50-316/98-24 on 981112-19 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of DC Cook Facility ML20154L9861998-10-13013 October 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $500,000.Violation Noted:As of 980227,licensee Had Not Provided Instructions Appropriate to Circumstances for Activity Affecting Quality IR 05000315/19980111998-06-0202 June 1998 Partially Withheld Insp Repts 50-315/98-11 & 50-316/98-11 on 980504-08 (Ref 10CFR73.21(c)(2)).No Violations Noted.Major Areas Inspected:Security Program Plans,Security Program Procedures,Security Organization & Administration IR 05000315/19970191997-11-24024 November 1997 Partially Withheld Insp Repts 50-315/97-19 & 50-316/97-19 on 970929-1003 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Staff Knowledge & Performance,Training & Qualification Program & Organization & Administration IR 05000315/19970071997-04-25025 April 1997 Partially Withheld Insp Repts 50-315/97-07 & 50-316/97-07 on 970324-28 (Ref 10CFR73.21).No Violations.Major Areas Inspected:Review of Physical Security Program IR 05000315/19960081996-10-25025 October 1996 Insp Repts 50-315/96-08 & 50-316/96-08 on 960909-13.No Violations Noted.Major Areas Inspected:Licensee Assessment of Performance in Area of Physical Security PNO-III-94-006, on 940121,licensee Commenced Shutdown of Unit 2 to Repair Steam Leak That Was Discovered in Vicinity of SG 1.Leak Was Repaired 940125 & Plant Has Commenced Startup1994-01-25025 January 1994 PNO-III-94-006:on 940121,licensee Commenced Shutdown of Unit 2 to Repair Steam Leak That Was Discovered in Vicinity of SG 1.Leak Was Repaired 940125 & Plant Has Commenced Startup IR 05000315/19930231993-12-0202 December 1993 Partially Withheld Insp Repts 50-315/93-23 & 50-316/93-23 on 931117-19 & 22-24 (Ref 10CFR73.21).No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Physical Barriers IR 05000315/19930021993-02-0505 February 1993 Partially Withheld Insp Repts 50-315/93-02 & 50-316/93-02 on 930119-22.No Violations Noted.Major Areas Inspected:Mgt Support,Protected & Vital Area Physical Barriers,Detection Sys & Detection Aid & Protected & Vital Area Access Control PNO-III-92-045, on 920908,unit Shut Down Due to High Generator Vibrations.Cause Undetermined.Licensee Will Remove & Inspect Generator Rotor1992-09-0909 September 1992 PNO-III-92-045:on 920908,unit Shut Down Due to High Generator Vibrations.Cause Undetermined.Licensee Will Remove & Inspect Generator Rotor IR 05000315/19910111991-06-27027 June 1991 Insp Repts 50-315/91-11 & 50-316/91-11 on 910501-0614.No Violations Noted.Major Areas Inspected:Plant Operations, Reactor Trip,Maint & Surveillance,Engineering & Technical Support & Actions on Previously Identified Items IR 05000315/19900231990-11-29029 November 1990 Insp Repts 50-315/90-23 & 50-316/90-23 on 901010-901113.No Violations Noted.Major Areas Inspected:Plant Operations & Maintenance & Surveillance PNO-III-90-049, on 900713,one Person Killed & Three Others Injured When Fatally Injured Worker Touched Live Contact in 4-kV Cabinet.Licensee Declared Unusual Event Under Emergency Plan & Subsequently Terminated1990-07-13013 July 1990 PNO-III-90-049:on 900713,one Person Killed & Three Others Injured When Fatally Injured Worker Touched Live Contact in 4-kV Cabinet.Licensee Declared Unusual Event Under Emergency Plan & Subsequently Terminated PNO-III-90-033, on 900524,licensee Declared Emergency Plan After 765KV Switchyard Breaker Opened Unexpectedly & Control Room Received Rept of Fire & Explosion.Caused by Burning Oil from Crosstie Breaker L.Unit 1 Reduced Power to 62%1990-05-24024 May 1990 PNO-III-90-033:on 900524,licensee Declared Emergency Plan After 765KV Switchyard Breaker Opened Unexpectedly & Control Room Received Rept of Fire & Explosion.Caused by Burning Oil from Crosstie Breaker L.Unit 1 Reduced Power to 62% IR 05000315/19880181988-08-19019 August 1988 Partially Withheld Insp Repts 50-315/88-18 & 50-316/88-21 on 880705-21 (Ref 10CFR73.21).Noncompliances Noted.Major Areas Inspected:Mgt Effectiveness,Records & Repts,Testing & Maint, Power Supply,Lighting,Compensatory Measures & Vital Areas IR 05000315/19870421987-12-30030 December 1987 Partially Withheld Insp Repts 50-315/87-42 & 50-316/87-42 on 871207-10 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Personnel Training & Qualifications,Safeguards Contingency Plan & Compensatory Measures ML20235W2421987-10-0909 October 1987 Exam Repts 50-315/OL-87-02 & 50-316/OL-87-02 on 870804-07. Exam results:3 of 5 Senior Reactor Operator Candidates & 10 of 11 Reactor Operator Candidates Passed Exams ML20235E2681987-09-16016 September 1987 Exam Rept 50-315/OL-87-01 for Units 1 & 2 on 870622-24.Exam Results:Seven Senior Reactor Operators & Two Reactor Operators Failed PNO-III-87-113A, updates Util Evaluation of Defective & Incorrectly Installed Bolts in Facility Containment Access Area.Caused by Use of Improper Cutting & Welding Procedure. Evaluation Continuing1987-09-0303 September 1987 PNO-III-87-113A:updates Util Evaluation of Defective & Incorrectly Installed Bolts in Facility Containment Access Area.Caused by Use of Improper Cutting & Welding Procedure. Evaluation Continuing IR 05000206/19870141987-08-31031 August 1987 Insp Repts 50-206/87-14,50-361/87-13 & 50-362/87-15 on 870524-0704.Violations Noted.Major Areas Inspected: Operational Safety Verification,Evaluation of Plant Trips & Events,Monthly Surveillance Activities & Maint Activities PNO-III-87-100, on 870723,unusual Event Declared When Contractor Employee Wearing Slightly Contaminated Clothing Taken to Local Hosp.When Clothing Removed,Surveys of Individual & Hosp Showed No Contamination1987-07-24024 July 1987 PNO-III-87-100:on 870723,unusual Event Declared When Contractor Employee Wearing Slightly Contaminated Clothing Taken to Local Hosp.When Clothing Removed,Surveys of Individual & Hosp Showed No Contamination PNO-III-87-098, on 870714,undervoltage on Reactor Coolant Pump Bus Occurred.Caused by Tripping of Unit from 80% Power Due to Voltage Variation.Licensee Decided to Shut Down Unit to Repair Minor Leaks in Reactor Cooling Sys1987-07-15015 July 1987 PNO-III-87-098:on 870714,undervoltage on Reactor Coolant Pump Bus Occurred.Caused by Tripping of Unit from 80% Power Due to Voltage Variation.Licensee Decided to Shut Down Unit to Repair Minor Leaks in Reactor Cooling Sys PNO-III-87-081, on 870610,earthquake Measuring 5.0 on Richter Scale Occurred Near Lawrenceville,Il.Unusual Events Declared by Six Power Stations But No Damage Observed.Ground Motion Felt at Five Other Plants1987-06-11011 June 1987 PNO-III-87-081:on 870610,earthquake Measuring 5.0 on Richter Scale Occurred Near Lawrenceville,Il.Unusual Events Declared by Six Power Stations But No Damage Observed.Ground Motion Felt at Five Other Plants IR 05000315/19870041987-03-17017 March 1987 Safety Insp Repts 50-315/87-04 & 50-316/87-04 on 870127-0223.No Violations or Deviations Noted in Five of Six Areas Inspected.Violation Re Visitor Escort Deficiency Addressed in Insp Repts 50-315/87-08 & 50-316/87-08 IR 05000315/19870081987-03-16016 March 1987 Partially Withheld Insp Repts 50-315/87-08 & 50-316/87-08 on 870127-0223 (Ref 10CFR73.21).Violation Noted:Visitor Escort Deficiency ML20207R3701987-03-0909 March 1987 EN-87-015:on 870312,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $50,000 Will Be Issued for License.Action Based on Violation of Tech Spec Re ECCS Subsystems PNO-III-87-032, on 870302,slow,steady Increase in Primary to Secondary Steam Generator Tube Leakage Monitored.On 870303, Leak Estimated at 0.2 Gpm & Unit Taken Out of Svc.Tube Will Be Repaired & Surveillance & Maint Program Implemented1987-03-0404 March 1987 PNO-III-87-032:on 870302,slow,steady Increase in Primary to Secondary Steam Generator Tube Leakage Monitored.On 870303, Leak Estimated at 0.2 Gpm & Unit Taken Out of Svc.Tube Will Be Repaired & Surveillance & Maint Program Implemented IR 05000315/19860381987-03-0303 March 1987 Addendum to Insp Repts 50-315/86-38 & 50-316/86-38,providing Criteria for Comparing Results of Capability Tests & Verification Measurements IR 05000315/19870061987-02-26026 February 1987 Insp Repts 50-315/87-06 & 50-316/87-06 on 870209-11.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise.Exercise Weakness Noted in Area of Protective Action Recommendations IR 05000315/19870051987-02-20020 February 1987 Insp Repts 50-315/87-05 & 50-316/87-05 on 870211-12.No Violations or Deviations Noted.Major Areas Inspected:Insp, Testing & Seal Replacement Program for Large Bore Steam Generator Snubbers ML20211J5281987-02-18018 February 1987 Notice of Violation from Insp on 861216-870126 IR 05000315/19870031987-02-18018 February 1987 Insp Repts 50-315/87-03 & 50-316/87-03 on 861216-870126. Violations Noted:Untimely Return to Svc Testing & Inappropriate Surveillance Test Acceptance Criteria IR 05000315/19860411987-01-16016 January 1987 Insp Repts 50-315/86-41 & 50-316/86-41 on 861104-1215. Apparent Violation Noted:Failure to Perform Timely post- Maint Operability Test on Valve & Subsequent Performance of Opposite Train Maint Being Tracked as Unresolved Issue ML20207P5111987-01-0606 January 1987 Exam Rept 50-315/OL-86-03 on 861202-04.Exam Results:Two Senior Reactor Operators & Two Retake Reactor Operators Passed IR 05000315/19860391986-12-0101 December 1986 Partially Withheld Physical Protection Insp Repts 50-315/86-39 & 50-316/86-39 on 861103-06 (Ref 10CFR73.21). No Violations Noted.Licensee Identified Concerns Re Personnel Access Control Program & Contingency Personnel IR 05000315/19860401986-11-28028 November 1986 Insp Repts 50-315/86-40 & 50-316/86-40 on 861103-07.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program ML20214F8181986-11-18018 November 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000.Violations Noted:Wire Lifted at Same Time & Crossed in Power Range Nuclear Instrument Channel NI-41 Without Use of Lifted Wire Form ML20214A3261986-11-13013 November 1986 EN-86-085:on 861118,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $25,000 Issued Based on Failure of Personnel to Follow Procedures,Rendering Two of Four power-range ex-cores Inoperable PNO-III-86-130, on 861105,during QA Audit of Contractor, Access Badges Removed Due to Inadequacies W/Screening Program.Employees Not Permitted to Return Until Screening Performed by Independent Organization1986-11-0606 November 1986 PNO-III-86-130:on 861105,during QA Audit of Contractor, Access Badges Removed Due to Inadequacies W/Screening Program.Employees Not Permitted to Return Until Screening Performed by Independent Organization IR 05000315/19860321986-10-17017 October 1986 Partially Withheld Reactive Physical Security Insp Repts 50-315/86-32 & 50-316/86-32 on 860818-22 & 0908-11 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected: Inadequate Maint of Safety Equipment.Details Withheld IR 05000315/19860361986-10-0101 October 1986 Insp Repts 50-315/86-36 & 50-316/86-36 on 860922-23.No Violations,Weaknesses or Deviations Noted.Major Areas Inspected:Emergency Preparedness Drill Involving Observations of Key Functions & Locations PNO-III-86-096, on 860911,bomb Threat Received at Telephone Switchboard,Stating That Bomb Placed in Training Ctr.Ctr Evacuated & Facility Searched.No Bomb Found.Nrc Info Assessment Team Notified1986-09-12012 September 1986 PNO-III-86-096:on 860911,bomb Threat Received at Telephone Switchboard,Stating That Bomb Placed in Training Ctr.Ctr Evacuated & Facility Searched.No Bomb Found.Nrc Info Assessment Team Notified PNO-III-86-094, on 860910,federal Grand Jury in State of Mi Western District Indicted Util & Jg Del Percio W/Violations of NRC Fire Protection Requirements Occurring from Mar 1981 - Apr 19821986-09-10010 September 1986 PNO-III-86-094:on 860910,federal Grand Jury in State of Mi Western District Indicted Util & Jg Del Percio W/Violations of NRC Fire Protection Requirements Occurring from Mar 1981 - Apr 1982 ML20206N4901986-08-21021 August 1986 Notice of Violation from Insp on 860707-11 IR 05000315/19860271986-08-20020 August 1986 Insp Repts 50-315/86-27 & 50-316/86-27 on 860707-11. Violation Noted:Failure to Adequately Test ESF Response Time in Unit 1 Steam Generator Water Level hi-hi Level Turbine Trip Reactor Trip Test PNO-III-86-072, on 860722,reactor Tripped While Operating at 90% Power.Caused by Workman Error While Attempting to Calibr Stator Cooling Water Pressure Switches.Util Will Proceed to Cold Shutdown for Repairs & Perform Snubber Surveillances1986-07-23023 July 1986 PNO-III-86-072:on 860722,reactor Tripped While Operating at 90% Power.Caused by Workman Error While Attempting to Calibr Stator Cooling Water Pressure Switches.Util Will Proceed to Cold Shutdown for Repairs & Perform Snubber Surveillances ML20206R9231986-06-30030 June 1986 Exam Rept 50-315/OLS-86-02 on 860519-22.Results of Exam:All Senior Reactor Operator Candidates & Seven Reactor Operator Candidates Passed IR 05000315/19860161986-06-25025 June 1986 Insp Repts 50-315/86-16 & 50-316/86-16 on 860609-11.No Noncompliance,Deviation or Deficiency Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000315/19860241986-06-20020 June 1986 Partially Withheld Physical Security Insp Repts 50-315/86-24 & 50-316/86-24 on 860604-05 (Ref 10CFR73.21).Noncompliance Noted:Items Not Searched or Secured as Required by Security Plan 1999-10-15 |
Inspection Report - Cook - 1986039 | |
---|---|
Text
- . _ _ _ _ - _ _ - _ _ _ - _ _ _ _ _ _ _ _ _
.u U.S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-315/86039(DRSS); 50-316/86039(DRSS)
Docket Nos. 50-315; 50-316 Licenses No. DPR-58; DPR-74 Safeguards Group IV Licensee: American Electric Power Service Corporation Indiana and Michigan Electric Company 1 Riverside Plaza Columbus, OH 43216 Facility Name: Donald C. Cook Nuclear Power Station, Units 1 and 2 Inspection At: Donald C. Cook Site, Bridgman, Michigan Inspection Conducted: November 3-6, 1986 Date of Last Physical Protection Inspection: August 18-22 and *
September 8-11, 1986 Inspector: If I'}ff!f0 T'gry ge J. Madeda Date Pnysical Security Inspector QQ.Q es L. Belanger t7lt{fb Date ysical Security Inspector Approved By: /df'ffh
,
mes R. Creed, Chief Date afeguards Section Inspection Summary Inspection on November 3-6, 1986 (Reports No. 50-315/86039(DRSS); l No. 50-316/86039(DRSS))
Areas Inspected: Included Management Effectiveness; Security Organization; Testing and Maintenance; Physical Barriers - Protected and Vital Areas; and Access Control - Personnel, Packages and Vehicle Results: The licensee was found to be in compliance with NRC requirements within the areas examined. Two licensee identified violations concerning failure to adequately implement some portions of the persennel access control program and one open item regarding the licensee's ability to adequately provide contingency personnel were identified and are being addressed by the license ~
PDR L :lc;ur'! contains G
ADOCK 05000315 PDR S JECT,5S 17C.LTI U m 5:pration this pg a is Decontrolled