Text
(
.
a
.
U. S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-315/86003(DRSS); 50-316/86003(DRSS)
Docket Nos. 50-315; 50-316 Licenses No. DPR-58; DPR-74 Safeguards Group IV Licensee:
American Electric Power Service Corporation Indiana and Michigan Electric Company 1 RiversiUe Plaza Columbus, OH 43216 Facility Name:. Donald ~C. Cook Nuclear Power Plant,' Units 1 and 2 Inspection At:
Donald C. Cook Site, Bridgman, MI Inspection Conducted:
January 13-16, 1986 Date of Last Physical Protection Inspection:
November 18-21, 1985 Type of Inspection:
Unannounced,. Reactive Physical Security Inspectors:
w, Me/m 2/}//ft T. J/t%deda Dstd Physical Security Inspector hh[
S/
R. Kniceley Date hysical Security Inspector h!86 Approved By:
34.t(
As R. Creed,' Chief Date Wafeguards Section
.
Inspection Summary Inspection on January 13-16, 1986 (Reports No. 50-315/86003(DRSS);
50-316/86003(DRSS))
Areas Inspected:
Included a review of Security Management Effectiveness; Security Organization; Security Program Audit; Testing and Maintenance; Physical Barriers - Vital Areas; Access Control - Personnel and Vehicles; Enclosure contains
-
SRFEGUARDS INFORMATION
0230 85000315
%21 DOCg 0 PDR Upon separation thisf Page is Decontrolled a
(I
.
.
Commun'ications; Compensatory Measures; and, Personnel, Training and-
. Qualifications - General Requirements.
These areas were selected for review based on previously. identified problems.
The_ inspection involved 60 direct
' inspection-hours.by two NRC inspectors.
Results: The licensee was found to be in compliance with NRC requirements in the areas inspected, except for the following two itens:
a.
Testing and Maintenance:
The licensee failed to correct deficiencies with security equipment in a timely. manner.
b.
Access Control - Personnel:
The licensee failed to adequately search some individuals and failed to utilize operational access control equipment.
(Details:. UNCLASSIFIED )
.
-,
Enclosure contains Upon separation this, page is Decontrolled
f