g,

-

O f;

9.,;

,

by3s

<

L'

MAR L-8 1990'

i

'

.

'

In Reply Refer To:.

.

Dockets: 50-313/89-47 50-368/89-47c

,.

5

'

l Arkansas Power & Light Company

' ATTN: Gene Campbell, Vice President

Nuclear. Operations P.O. Box 551'

Little Rock, Arkansas 72203

-

Gentlemen:

<

Thank you for your letter of February 20, 1990, in response to our letter and Notice of Violation dated January 19, 1990. We have reviewed your reply and find it responsive to the concerns raised in our Notice of' Violation. We

will review the implementation of your corrective actions during a future inspection to determine that full compliance has been achieved and will be maintained.

I

Sincerely, Original Signed By

,

Samuel-J. Collins, Director Division of Reactor Projects cc:

' Arkansas Nuclear One ATTN:

Early Ewing, General Manager Technical Support and Assessment P.O. Box 608.

Russellville, Arkansas 72801 Arkansas Nuclear One ATTN: Keil Carns,-Director

~ Nuclear Operations P.O. Box 608 Russellville, Arkansas 72801

.'

,

  • RIV:FRPS
  • C:FRPS
  • D:DRSS D:

LTRicketson:cd BMurray ABBeach SJ ins l-

/ /90

/ /90

/ /90 S/6/90 l

  • Previously. concurred

.m

$@$32ggggk$$$$

i gp o

M Q

- - - - -

p g.

h k ig*

-

.

.

'

Arkansas Power & Light Company!

-2-

.

'

p

~ Comb ~ustion Engineering, Inc.

ATTN: Charles B. Brinkman, Manager L

Washington Nuclear Operations

'

/12300 Twinbrook Parkway, Suite 330 Rockville, Maryland _20852 Honorabie Joe _W. Phillips-

-

!

County Judge of Pope County Pope County Courthouse l

Russellville, Arkansas '72801-Bishop; Cook, Purcell &_Reynolds ATTN:. Nicholas S. Reynolds, Esq.

.

1400 L Street, N.W.

' Washington,-D.C.

20005-3502 Arkansas Department of Health ATTN: - Ms. Greta Dicus, Director Division-of Environmental Health Protection.

4815 West Markam Street Little Rock, Arkansas 72201

,

Babcock & Wilcox Nuclear Power Generation Division

,

ATTN: Mr. Robert B. Borsum

!

1700 Rockville Pike,: Suite 525-a Rockville, Maryland, 20852

!

-

U.S. Nuclear Regulatory Commission

!

ATTN: Senior Resident Inspector

'l Nuclear-Plant Road

.Russellville, Arkansas 72801 U.S.-~ Nuclear Regulatory Commission

-ATTN:- Regional-Administrator, Region IV

'

611 Ryan Plaza Drive, Suite 1000

' Arlington,- Texas 76011 j

,

bec to DMB (IE-06)

i l'

bec with licensee's letter:

l Resident Inspector I

'

FRPS File Section Chief, DRP/A

'

Lisa Shea, RM/ALF RIV File DRP-DRS

,

l MIS System i

RSTS Operator

!

Inspector Section Chief B. Beach i

'

' Project Engineer, DRP/A C. Harbuck, NRR Project Manager

' ~ i L,...

.

.. m v ;

'[

Arkansas Power & Ught Company

-(

s'~

Arkansas Nuclear One

' C- ' *

Route 3 Box 137 G

'

in Russellville. AR 72801 Tel 501964 3100

,

,, _ _ _)@@$N$

-'

_

_

-,w,.e--

L/

'

,

FEB 2 31990

- February 20, 1990

.

N

.,

~

BCAN029010

"

- U. S. Nuclear Regulatory Commission

.

Document Control Desk Mail Station PI-137 Washington, D. C.

20555'

SUBJECT:

Arkansas Nuclear One - Units 1 and 2 Docket Nos. 50-313/50-368 License Nos. DPR-51 and NPF-6 Response to Inspection Report 50-313/89-47; 50-368/89-47

.

Gentlemen:

Pursuant to the provisions of 10CFR2.201, attached is the response to

,

the violation identified in the subject inspection report.

,

Very truly yours,

,'4c9

~

^

E. C. Ewing General Manager, Technical Support and Assessment ECE/DWB/abw attachment

,.

I-cc:

Regional Administrator Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

,

i

.

g_po-cg,t[.

  • , se, cm.,

.

g

..

..

I;*..

[?

U.S. NRC

~*

Attachment Page 1-February 20, 1990

. Notice of Violation Failure to Follow Procedure

'

Technical Specifications 6.10 and 6.11 for Arkansas Nuclear One, Units 1 and 2, respectively, require that procedures for personnel radiation safety shall be adhered to for all operations involving personnel radiation safety.

Procedure 1000.031, " Radiation Protection Manual," states in Section 6.7.2.B

"All workers are responsible for following RWP (radiation work permit) requirements during each access to an RCA (radiological controlled area)... Workers shall review and acknowledge understanding of the RWP immediately prior to each RCA entry."

Radiation Work Permit 892249 issued November 27, 1989, to cover work activities associated with minor maintenance activities, requires, "Whenever exiting any radiological controlled area outside of controlled access, all personnel will... proceed immediately to PCM (personnel contamination monitors) and perform a whole body frisk in the PCM-1B."

!

Contrary to the above, on December 13, 1989, an individual stated to the I

inspector, during an interview, that he worked in the controlled area around the old radioactive waste building on December 10, 1989, but did not perform

,i a whole body frisk after leaving the area.

The licensee acknowledged that the individual had not read RWP 892249, which covered the work.

'

This is a Severity Level IV violation.

(Supplement IV (313/8947-01; 368/8947-01)

Response to the Violation 313-368/8947-01 l

(1) The reason for the violation:

The reason for the violation is attributed to personnel error.

The indi-vidual involved in this incident admitted that he did not read the Radiation Work Permit (RWP) and, subsequently, failed to perform a whole body frisk in accordance with the requirements of the RWP.

(2) The corrective steps which have been taken and the results achieved:

The individual received counselling and a written reprimand. The individual acknowledged that he understood the severity of his error.

During the daily Manager's Meeting on February 16, 1990, the importance of ensuring that personnel read and understand the information in RWPs was emphasized.

.

.

_ _ - - _ _ _

{..

.

.m, 6%

0.S. NRC

. Attach:ent-J

,

Page 2 february 20, 1990 (3) The corrective steps which will be taken to avoid further violations:

A program is being implemented which will identify personnel failing to

read their RWP.

Personnel observed failing to read their RWP will be restricted from entering RCAs until appropriate corrective action is taken by their management.

The individual's supervision will be responsible for administering disciplinary actions and for notifying the Manager - Rad Protection and Radwaste of the corrective actions taken.

The Manager - Rad Protection and Radwaste will review the corrective actions to determine if the individual's access to the RCAs should be reinstated.

.u A memorandum was distributed to all ANO personnel on February 20, 1990, informing them of the new policy regarding the increased attention to

" failure to read RWP" incidents and enforcement of the requirement.

This incident also pointed out potential weaknesses in the location, quantities, setpoints and proper use of personnel contamination monitors on site.

An evaluation is in progress to address each of these items.

This evaluation will be completed by April 20, 1990.

Additionally, specific training sessions were scheduled to address the operation and proper use of the PM-7 Portal Monitor.

This training was offered during the period from December 19, 1989 through January 31, 1990.

As an interim measure prior to completion of this training, a health physics technician was assigned to the Main and Secondary Guard Stations, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day, to monitor the egress of plant personnel through the PM-7 Portal Monitors as personnel exited the plant.

(4) The date when full compliance will be achieved:

Full compliance has been achieved.

L L

i l'

l'