y,,qm q r-..- ---., v n yggy p" ""%

0;......

......d

'

.

O NUCLEAR REGULATORY COMMISSION

/

t,

y REGION 11 S-T2 M

ie7

-

o, 101 MARIETTA ST., N.W.. sulTE 3100

% ***** e'g

,,

,.

,,.

ATLANTA. GEORGIA 303o3 E

' ~ ~ *

'

-[

JU N 161980 3 m --

as repreduccd.. ' ru cpacific approval cf I:-II Report Nos. 50-259/80-22, 50-260/80-16, and 50-296/80-17 Docket Nos. 50-259, 50-260, and 50-296 License Nos. DPR-33, DPR-52 and DPR-68 Licensee: Tennessee Valley Authority 500A Chestnut Street Chattanooga, TN 37401 Facility Name: Browns Ferry 1, 2, and 3 Insp( : tion at: Browns Ferry Nuclear Plant, near Decatur, AL

,

Inspection conducted: May 19-23, 1980 Date of Last Physical Security Inspection Visit: March 11-14, 1980 Type of Inspection-Unafi,ou ed Physical Security Inspectors:

,MM b[ M

'

'

,

A.'Ti an'.

  • '

/'

/Date

,j'

p..A 6&

,c~W. J.

'i "

/

Dat'e

~

)],b

/

Approve by:

.

F. 'P.~Gillespief Acting Chief, Security Section

/Date Inspection Summary Areas Inspected:

Included review of security plan; security organization; security program audit; records and reports; testing and naintenance; locks and key control; physical barriers (protected and vital areas); power supply; lighting; assessment aids; access controls (search, escort, vital areas);

detection aids; communications.

The inspection involved 80 inspector hours on site by two NRC inspectors. Twenty inspcction hours were accomplished during offshift periods.

Results: Of the 16 areas inspected, no apparent items of noncompliance were identified in 12 areas; four items of noncompliance were identified in the other four areas.

1.

Physical Barriers - Vital area barrier incomplete (259/80-22-01).

2.

Key and Lock Control - Inadequate installation of lock (296/80-17-01).

3.

Assessment Aids - CCTV surveillance capability not redundant (259/80-22-02).

4.

Access Control - Vehicle escort not equipped with portable radio (259/80-22-03).

f. 51.13. - ---- e n~g.3y yy,

,

a00919 CL......; L...

.....;.i.D L

.