UNITED STATES

!

'n NUCLEAR REGULATORY COMMISSION E

I REGION 11

,

o,

[

101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 s

Special Report: WASTE PACKAGING INSPECTIONS OF LICENSEE-SHIPPERS REPORT NO. 60-8 Reference:

TI 2840/1, (Rev. 1), " Waste Packaging Inspections", 10/10/79 Licensee-Shipper:

Chem-Nuclear Systems, Inc.

P. O. Box 726, Barnwell, South Carolina 29812 Docket No. ;5000039 Disposal Site:

Chem-Nuclear Systems, Inc.

P. O. Box 726, Barnwell, South Carolina 29812 Docket No. 15000039 Inspector-M

o[Fo g T. C. PIacArthur,A adiation Specialist,

'Date Signe

-2-In adoition to the above, 49 CFR 177.817 requires carriers to maintain the above shipping papers readily available for inspection and recognizable by authorities in case of an accident.

No items of noncompliance were identified.

5.

Each vehicle was inspected for conformance with DOT placarding requirements (49 CFR 172, Subpart F and 49 CFR 173.392). The vehicles were also inspected for compliance with the following:

Maximum transportation index of 50 - (49 CFR 177.842)

Loaded so as to avoid spillage (49 CFR 177.842)

Properly blocked and braced (49 CFR 173.392/177.842)

LSA vehicle survey (49 CFR 177.843)

No items of noncompliance were identified.

6.

Maximum Radiation Levels Each truck was surveyed for maximum radiation leve:

the normally occupied portions of the vehicle, in a plane at the edge t_

.ie flat bed or at the

.

surface of the closed vehicles, in a vertical plane six feet from the sides of the vehicle where possible, and on the surface of a representative package. Shipping cask were surveyed at the surface.

No levels were in nancompliance with 49 CFR 173.393 limits.

7.

Packaging A representative sampling of packages from each shipment was examined for conformance with DOT marking and labeling requirements. External features of the packages were examined for conformance with DOT and NRC requirments as noted below:

Low specific activity (LSA) packaging 49 CFR 173.392

-

Tight packagas - ltd. Qty.,

49 CFR 173.391 or 173.392

-

No release of material

-

49 CFR 173.392/173.393 Radioactive material markings 49 CFR 172.310

-

Security seals 49 CFR 173.393

-

Gross weight requirements

-

49 CFR 172.310 Proper shipping name

-

49 CFR 172.100/172.300 LSA labeling 49 CFR 173.392

-

Cask design specifications 49 CFR 173.393a

-

No items of noncompliance were identified.

.

.

.

i ATTACHMENT A NRC SSR #

Region Carrier Trailer #

Shipper 020499 II Home 039 Carolina Power & Light Company 020570 II CNSI 136003 Brunswick Electric Steam Plant P. O. Box 10429 Southport, NC 28461 Docket / Report Nos. 50-325/80-25 50-324/80-22

,

020518 III TSMT 72235 Indiana & Madison Electric Cr.

020593 III TSMT 232267 Donald C. Cook Reactor P. O. Box 458

'

Bridgman, MI 49106 020528 II CNSI 130 D (6/4)

Westinghouse Electric Company 020563 II CNSI 126 D (6/4)

P. O. Drawer R 020564 II CNSI 127 D (6/4)

Columbia, SC 29250 020574 II CNSI 127 D (6/5)

Docket Report Nos. 70-1151/80-16 202575 II CNSI 130 D (6/5)

020577 II CNSI 129 D (6/5)

020578 II CNSI 126 D (6/5)

'

020538 I

McCormack 217 Jersey City Power & Light 020581 I

McCormack 218 RI #9 Oyster Creek Forked River, NJ 08731 020539 II Mason-Dixon 42130 TNS, Inc.

P. O. Box 158

'

Jonesboro, TN 37663 020540 II TSMT 052 Carolina Power & Light Company I

H. B. Robinson Plant P. O. Box 790 Hartsville, SC 29550

,

'

Docket / Report No. 50-261/80-11 020541 III CNSI 019 Wisconsin Electric Power Co.

Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, WI 54241 020543 I'

Hittman 72485 Boston Edison Company 020544 I

CNSI 214002 Rocky Hill Road Plymouth, MA 02360 F

. _-

.

Atachment A-2-

.

NRC SSR #

Region Carrier Trailer #

Shipper 020545 I

CNSI 048 Public Service Electric & Gas P. O. Box 168 Hancock's Bridge, NJ 03038 020553 II Home 024 Georgia Power Company 020576 II CNSI

Plant E. I. Hatch U.S.-1 Baxley, GA 31513 Docket /Repot Nos. 50-321/80-25 50-366/80-25 020558 I

CNSI 027 Northeast Nuclear Energy Co.

Rope Valley Road Box 128 Waterford, CT 06360 020559 II CNSI 023 Duke Power Company 020592 II TSMT 544121 Oconee Nuclear Station P. O. Box 1439 Seneca, SC 29678 Docket / Report Nos. 50-269/80-21 50-270/80-17, & 50-287/80-15 020560 III Hittman 72229 Commonwealth Edison 020595 III Hacke 72230 RR #1 Morris, IL 60450 020561 I-CNSI 010 Connecticut Yankee Atomic Power Co.

RR #1, Box 127E

,

East Hampton, CT 06424

__

020562 I

Hittman 72237 Peach Bottom Atomic Power Station RD #1 Delta, PA 17314 020567 I

McCormack

Baltimore Gas & Electric Company 020594 I

Superior 018 Rts. 2 & 4

Calvert Cliff NPD

'

Lusby, MD 20657 020568 I

TSMT 440219 Vermont Yankee Nuclear Power Co.

P. O. Box 157 Vernon, VT 05354

_. _ -

-

,

O Atachment A-3-t NRC SSR #

Region Carrier Trailer #

Shipper 020569 I

Home 136001 Power Authority of the State of New York J. A. Fitzpatrick Nuclear Power Plant P. O. Box 41 Lycoming, NY 13093 02573 II East-Coast 035 Florida Power & Light Company Palm Drive Florida City, FL 33152 Docket / Report Nos. 50-250/80-24 50-251/80-24 020582 II TSMT TV-45 Tennessee Valley Authority 020588 II TSMT TV-83 Browns Ferry Nuclear Plant Athens AL 35611 Docket / Report No. 50-259/80-26 020589 II Spector 23156 Babcock & Wilcox, NNFD P. O. Box 785 Lynchburg, VA 24505 Docket / Report No. 70-27/80-10 020590 IV TSMT 72238 Arkansas Nuclear One P. O. Box 608 Russelville, AR 72801 020591 I

TSMT 128103 Maine Yankee Atomic Power Co.

RFD-2, Box 450 Wiscasset, MC 04578 020596 III TSMT 44452 Iowa Electric Light & Power Co.

P. O. Box 351 Duane Arnold Energy Center Cedar Rapids, IA 52406 20600 III Hacke 72234 Commonwealth Edison 200597 III McCormack 214 Quad Citites Station

.

'

22710 206 Ave North Cordova, IL 61242 0200601 I

Spector 6125 Nuclear Metals, Inc.

2229 Main Street Concord, MA 01742 i

-

1