| Site | Company⠉ | Quarter | Title | Significance | Inspection procedure | Topic |
---|
05000482/FIN-2018010-05 | Wolf Creek | Wolf Creek Nuclear Operating Corporation | 2018Q3 | Licensee-Identified Violation | Green | IP 71152, Problem Identification and Resolution (PI&R) | Boric Acid |
05000482/FIN-2018010-03 | Wolf Creek | Wolf Creek Nuclear Operating Corporation | 2018Q3 | Failure to Correct Reoccurring Problems with Time Critical/Sensitive Action Activities | Green | IP 71111.21M, Design Bases Assurance Inspection | |
05000528/FIN-2018008-04 | Palo Verde | Arizona Public Service | 2018Q3 | Minor Violation | Severity level Minor | IP 71152, Problem Identification and Resolution (PI&R) | |
05000528/FIN-2018008-01 | Palo Verde | Arizona Public Service | 2018Q3 | Inadequate Corrective Actions For Missing Control Room Hand-Switch Operator Knob | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000306/FIN-2018003-04 | Prairie Island | Xcel Energy | 2018Q3 | Failure to Promptly Identify and Correct 21 125 VDC Battery Lid Conditions Adverse to Quality | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000282/FIN-2018003-03 | Prairie Island | Xcel Energy | 2018Q3 | Failure to Promptly Identify Degradation of the 122 DDCLP FOST Vent Piping | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality |
05000275/FIN-2018003-02 | Diablo Canyon | Pacific Gas & Electric | 2018Q3 | 4 kV Vital Switchgear Room Ventilation Degraded or Non-Conforming Condition and Associated Compensatory Measure Not Corrected in a Timely Manner | Green | IP 71152, Problem Identification and Resolution (PI&R) | Operability Assessment |
05000277/FIN-2018003-02 | Peach Bottom | Constellation | 2018Q3 | Inadequate Corrective Actions Result in the Failure of the E-3 EDG | White | IP 71153, Event Followup | Preliminary White Finding |
05000395/FIN-2018003-02 | Summer | South Carolina Electric & Gas Company | 2018Q3 | Minor Violation | Severity level Minor | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality |
05000289/FIN-2018003-01 | Three Mile Island | Constellation | 2018Q3 | 1A Emergency Diesel Generator Lube Oil Leak Inadequate Corrective Actions | Green | IP 71111.22 | |
05000263/FIN-2018012-02 | Monticello | Xcel Energy | 2018Q3 | Failure to Implement Adequate Freeze Protection Monitoring for Condensate Storage Tank Instrumentation Piping in Response to Industry Operating Experience | Green | IP 71111.21M, Design Bases Assurance Inspection | |
05000313/FIN-2018011-02 | Arkansas Nuclear | Entergy | 2018Q3 | Failure of Both Arkansas Nuclear One Units to Establish Adequate Corrective Actions Resulting in Excessive Instances of Damaged and Broken Internals of the Emergency Feedwater Pum o Turbine Steam Admission Check Valves. | Green | IP 71111.21M, Design Bases Assurance Inspection | |
05000348/FIN-2018002-04 | Farley | Southern Nuclear | 2018Q2 | Failure to implement timely corrective actions for charging pump discharge check valves | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality |
05000387/FIN-2018002-01 | Susquehanna | Talen Energy | 2018Q2 | Control Structure Chiller Inoperability Due to Identified Refrigerant Leaks Not Corrected | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality |
05000400/FIN-2018002-01 | Harris | Duke Energy | 2018Q2 | Failure to Promptly Identify and Correct a Condition Adverse to Quality For a Through-Wall Leak in the ESW Screen Wash Piping | Green | IP 71111.04 | Condition Adverse to Quality Through-Wall Leak |
05000277/FIN-2018002-01 | Peach Bottom | | 2018Q2 | Failure to Identify and Promptly Correct a Condition Adverse to Quality Concerning Battery Charger 2B-003-1 | Green | IP 71111.19 | Condition Adverse to Quality |
05000414/FIN-2018002-01 | Catawba | Duke Energy | 2018Q2 | Failure to Identify and Correct CAQ Associated with Failure of the 2B Seal Water Injection Filter O-ring | Green | IP 71111.12 | Condition Adverse to Quality |
05000413/FIN-2018002-02 | Catawba | Duke Energy | 2018Q2 | Failure to Promptly Identify and Correct a Condition Adverse to Quality | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality |
05000275/FIN-2018008-03 | Diablo Canyon | | 2018Q2 | Failure to Promptly Identify and Correct Emergency Diesel Generator 1-1 Cardox System Inoperability | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000458/FIN-2018012-02 | River Bend | Entergy | 2018Q2 | Failure to Identify and Correct a Broken Feedwater Chemistry Probe | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000416/FIN-2018002-06 | Grand Gulf | Entergy | 2018Q2 | Improper Evaluation and Resolution of Intermediate Range MonitorNoise Leads to Manual Reactor Shutdown | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality |
05000413/FIN-2018001-01 | Catawba | | 2018Q1 | Failure to Ensure that Conditions Adverse toQuality Managed Outside of the Corrective Action Program are Corrected | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000416/FIN-2018001-01 | Grand Gulf | Entergy | 2018Q1 | Failure to Promptly Correct Lube Oil Leak on Division 2 Diesel Generator | Green | IP 71111.19 | Condition Adverse to Quality |
05000353/FIN-2018001-01 | Limerick | Constellation | 2018Q1 | Failure of Emergency Diesel Generator Lube Oil Pipe Nipple Fitting | Green | IP 71153, Event Followup | |
05000445/FIN-2018001-05 | Comanche Peak | Luminant | 2018Q1 | Failure to Correct a Significant Condition Adverse to Quality | Green | IP 71153, Event Followup | Condition Adverse to Quality |
05000315/FIN-2017004-03 | Cook | American Electric Power | 2017Q4 | Failure to Promptly Correct The CAQ by Not Testing the CCW Leak Isolation Valves | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality |
05000315/FIN-2017004-01 | Cook | American Electric Power | 2017Q4 | Failure to Correct Numerous Anchor Darling Double Disc Gate Valve Non-Conformances | Green | IP 71111.12 | Anchor Darling Operability Assessment |
05000454/FIN-2017010-03 | Byron | Constellation | 2017Q4 | Failure to Properly Correct Errors in Design Analysis for Main Steam Line Break in Main Steam Tunnel | Green | IP 71152, Problem Identification and Resolution (PI&R) | Significance Determination Process |
05000461/FIN-2017012-01 | Clinton | Constellation | 2017Q4 | Failure to Perform a Corrective Action to Prevent Recurrence | Green | IP 71153, Event Followup | Condition Adverse to Quality |
05000461/FIN-2017011-01 | Clinton | Constellation | 2017Q4 | Failure to Correct an Identified Degraded Condition on the Division 3 Shutdown Service Water Pump | White | IP 71152, Problem Identification and Resolution (PI&R) | Significance Determination Process |
05000395/FIN-2017004-02 | Summer | | 2017Q4 | Failure to Implement Corrective Actions to Restore Compliance for Previous NRC-identified Green NCV 05000395/2005007-01 | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000272/FIN-2017004-01 | Salem | PSEG | 2017Q4 | Non-conformance with the Containment Thermal Insulation System was not Identified and Corrected | Green | IP 71111.08 | |
05000335/FIN-2017004-03 | Saint Lucie | NextEra Energy | 2017Q4 | Failure to Identify and Correct a Condition Adverse to Quality | Green | IP 71153, Event Followup | Condition Adverse to Quality |
05000456/FIN-2017008-03 | Braidwood | Constellation | 2017Q4 | Failure to Properly Correct Errors in Design Analysis for Main Steam Line Break in Main Steam Tunnel | Green | IP 71152, Problem Identification and Resolution (PI&R) | Significance Determination Process |
05000323/FIN-2017003-01 | Diablo Canyon | | 2017Q3 | Inadequate Corrective Actions resulted in a Failure to Comply with Technical Specification 3.4.11 and an Emergency Declaration | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality Significance Determination Process |
05000446/FIN-2017003-01 | Comanche Peak | | 2017Q3 | Failure to Promptly Correct a Condition Adverse to Quality | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality Significance Determination Process |
05000266/FIN-2017003-02 | Point Beach | NextEra Energy | 2017Q3 | Service Water Cable Support Failure | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality Significance Determination Process |
05000313/FIN-2017007-01 | Arkansas Nuclear | | 2017Q3 | Failure to Promptly Identify and Correct an Inadequate Design Bases Calculation | Green | IP 71111.21N | Condition Adverse to Quality High Energy Line Break Significance Determination Process Maintenance Rule Program |
05000397/FIN-2017002-03 | Columbia | Energy Northwest | 2017Q2 | Inadequate Corrective Actions Causes Failure of HPCS Room Normal Supply Fan | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality Maintenance Rule Program |
05000348/FIN-2017007-02 | Farley | | 2017Q2 | Untimely Corrective Actions for Check Valve Q2E21V0026 | Green | IP 71111.21 | |
05000278/FIN-2017002-01 | Peach Bottom | | 2017Q2 | Corrective Action Not Implemented Correctly for Replacement of RCIC RCR Contacts | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality |
05000424/FIN-2017002-01 | Vogtle | Southern Nuclear | 2017Q2 | Failure to Correct a Condition Adverse to Quality involving an MSIV Manufacturing Deficiency | Green | IP 2515/150 | Condition Adverse to Quality |
05000458/FIN-2017007-02 | River Bend | | 2017Q2 | Failure to Perform an Adequate Operability Determination for a Condition Identified During an NRC Walkdow | Green | IP 71111.21 | Significance Determination Process Operability Assessment |
05000260/FIN-2017001-01 | Browns Ferry | Tennessee Valley Authority | 2017Q1 | Failure to Take Corrective Actions to Preclude a Repeat Failure of a Containment Isolation Valve | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Condition Adverse to Quality |
05000269/FIN-2017007-01 | Oconee | Duke Energy | 2017Q1 | Failure to Identify and Correct Broken Cable Trench Cover. | Green | IP 71111.21M, Design Bases Assurance Inspection | Condition Adverse to Quality |
05000220/FIN-2017001-02 | Nine Mile Point | Constellation | 2017Q1 | Failure to Identify and Correct a Non- Conforming Condition in Safety-Related UPSs | Green | IP 71152, Problem Identification and Resolution (PI&R) | Safe Shutdown Significance Determination Process |
05000445/FIN-2017001-04 | Comanche Peak | | 2017Q1 | Failure to Promptly Correct a Condition Adverse to Quality | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality Significance Determination Process Maintenance Rule Program Operability Assessment |
05000293/FIN-2016011-05 | Pilgrim | Holtec | 2017Q1 | Failure to Establish Corrective Actions to Address Scope of Procedure Quality Issues | Green | IP 95003 | Significance Determination Process |
05000277/FIN-2017008-01 | Peach Bottom | | 2017Q1 | Untimely Corrective Actions to Address 2C Core Spray Motor Elevated Vibrations | Green | IP 71152, Problem Identification and Resolution (PI&R) | Condition Adverse to Quality Maintenance Rule Program |
05000293/FIN-2016011-01 | Pilgrim | Holtec | 2017Q1 | Failure to Identify All Root Causes of a Significant Condition Adverse to Quality | Green | IP 95003 | Condition Adverse to Quality Significance Determination Process Operability Assessment |