Finding | |
---|---|
Title | Failure to Promptly Correct a Condition Adverse to Quality |
Description | Green. The inspectors identified a non-cited violation of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, associated with the licensees failure to take timely corrective actions for a previously identified condition adverse to quality. Specifically, the licensee failed to verify the adequacy of the design of the Unit 1 120 VAC vital bus inverter 1PC1 with respect to use of alternate AC power to the inverter. The 120 VAC calculation did not properly account for low voltage when the buses are supplied from their alternate source. This issue does not represent an immediate safety concern because, following the inspectors identification, the licensee performed an operability evaluation which established a reasonable expectation of operability. The licensee implemented immediate corrective actions by entering the issues into the corrective action program for resolution and performed an operability determination for the identified degraded conditions. The licensee entered this issue into their corrective action program as CR-2017-001296. The licensees failure to take timely and adequate corrective actions to correct a condition adverse to quality was a performance deficiency. The performance deficiency is more than minor, and therefore a finding, because it is associated with the equipment performance attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to correct the low voltage susceptibility resulted in delayed restoration of a bus following the failure of the swing inverter to sync. Using Inspection Manual Chapter 0609, Attachment 04, Initial Characterization of Findings, dated October 7, 2016, and Inspection Manual Chapter 0609, Appendix A, Significance Determination Process for Findings At-Power, Exhibit 2, Mitigating Systems Screening Questions, the inspectors determined the finding was of very low safety significance (Green) because the finding: (1) was not a deficiency affecting the design and qualification of a mitigating structure, system, or component, and did not result in a loss of operability or functionality, (2) did not represent a loss of system and/or function, (3) did not represent an actual loss of function of at least a single train for longer than its allowed outage time, or two separate safety systems out-of-service for longer than their technical specification allowed outage time, and (4) does not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in accordance with the licensees maintenance rule program. The finding has a human performance cross-cutting aspect associated with resources, in that, the licensee failed to ensure that resources were adequate to support nuclear safety [H.1]. |
Site: | Comanche Peak ![]() |
---|---|
Report | IR 05000445/2017001 Section 4OA2 |
Date counted | Mar 31, 2017 (2017Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | C Smith E Uribe G Pick J Braisted J Josey M Haire R Kumana S Hedger W Cullum |
Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion XVI Technical Specification |
CCA | H.1, Resources |
INPO aspect | LA.1 |
' | |