05000282/FIN-2011003-07
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | GL 2008-01 Evaluations Did Not Adequately Verify the Design for Susceptible Locations of Gas Accumulation in Piping Systems |
| Description | The inspectors identified a finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to adequately review the design of emergency core cooling, decay heat removal, and containment spray systems for gas susceptible locations. Specifically, the licensees original design reviews in response to Generic Letter 2008-01 did not identify all gas susceptible locations (i.e., pipe geometries that can accumulate gas). Corrective actions for this issue included the performance of ultrasonic examinations of most of the affected locations and did not find unacceptable void volumes. The licensee also evaluated the remaining locations for operability using alternative methods. There were no further operability concerns associated with these locations. The issue was entered into the CAP as CAP 1281658. The performance deficiency was determined to be more than minor because, if left uncorrected, it would have the potential to lead to a more significant safety concern. The finding is associated with the Mitigating Systems Cornerstone. The finding screened as of very low safety significance because the finding involved a design or qualification deficiency that did not result in a loss of operability. This finding had a cross-cutting aspect in the area of problem identification and resolution because the licensee did not implement operating experience through training. Specifically, although relevant operating experience associated with gas susceptible locations was implemented in the procedures used to review the piping system design, the training provided did not adequately address the concepts portrayed by the operating experience contained in these procedures. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2011003 Section 4OA5 |
| Date counted | Jun 30, 2011 (2011Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | J Jandovitz M Mitchell C Brown M Phalen K Stoedter D Betancourt J Corujo-Sandin E Sanchez N Feliz-Adorno S Lynch S Shah |
| CCA | P.5, Operating Experience |
| INPO aspect | CL.1 |
| ' | |
Finding - Prairie Island - IR 05000282/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2011Q2
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||