Finding | |
|---|---|
| Title | Failure to Follow Procedure Results in Removing Incorrect Radiation Monitor From Service |
| Description | A self-revealed finding of very low safety significance and an NCV of 10 CFR Part 50, Appendix B, Criterion V, was identified on November 12, 2010, due to the failure to follow procedure while transferring the power supply for motor control center 1T1 from Unit 1 to Unit 2. The failure to follow procedures resulted in removing safety-related radiation monitor 1R11/1R12 from service and an unplanned entry into TS 3.4.16.B. Corrective actions for this issue included returning radiation monitor 1R11/1R12 to service and re-enforcing the use of human performance tools to operations personnel. The inspectors determined that this issue was more than minor because, if left uncorrected, the performance of plant activities on the incorrect unit would become a more significant safety concern. The inspectors concluded that this finding was of very low safety significance because the removal of the radiation monitor from service was not a design deficiency; did not result in a loss of system safety function for greater than the TS allowed outage time; and was not potentially risk significance due to seismic, flooding or severe weather initiating events. The inspectors determined that this finding was cross-cutting in the Human Performance, Work Practices area because personnel failed to use human error prevention techniques to ensure that work was performed safely. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2010005 Section 4OA5 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | |
| Inspectors (proximate) | C Brown D Mcneil J Dalzell J Giessner K Stoedter L Kozak P Zurawski R Lerch |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Prairie Island - IR 05000282/2010005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2010Q4
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||