Finding | |
|---|---|
| Title | PORV Stroke Timing Acceptance Criteria Failed to Include Instrument Response Time |
| Description | The inspectors identified a finding having very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion XI, Test Control, for the licensees failure to ensure adequate acceptance limits were incorporated into test procedures. Specifically, the acceptance criteria for allowable pressurizer power operated relief valve (PORV) opening stroke time within the periodic test procedure was not consistent with the original design criteria for low temperature overpressure protection (LTOP) analysis. The acceptance criteria limits did not include the instrument response time. This finding was entered into the licensees corrective action program and a review of most recent tests showed the valves stroke time were acceptable and the valves were operable
The inspectors determined that this finding was more than minor because it was associated with the Barrier Integrity cornerstone attribute of design control and affected the cornerstone objective to provide reasonable assurance that physical design barriers (fuel cladding, reactor coolant system, and containment) protect the public from radionuclide releases caused by accidents or events. This finding was of very low safety significance (Green) because the function of the PORV opening in the required time had always been maintained and the finding did not result in non-compliance with LTOP TS. This finding did not have a cross-cutting aspect because it was not reflective of current performance. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2010006 Section 1R21 |
| Date counted | Sep 30, 2010 (2010Q3) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | J Chiloyan D Betancourt M Munir A Dahbur D Szwarc C Brown B Sherbin |