05000282/FIN-2010005-06
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Include 121 MDCLP Coupling Hardness Information in Procurement Document |
| Description | A self-revealed finding of very low safety significance and an NCV of 10 CFR Part 50, Appendix B, Criterion IV, was identified on July 25, 2010, due to the licensees failure to specify the required 121 motor driven cooling water pump shaft coupling hardness as part of the procurement process. As a result, the pump was rendered unavailable due to a shaft coupling failure due to excessive hardness of the shaft. Corrective actions for this issue included repairing the cooling water pump and revising the procurement documents to include the required coupling hardness. The inspectors determined that this issue was more than minor because it impacted the design control attribute of the Mitigating Systems Cornerstone. This finding also impacted the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The inspectors completed the Phase 1 and Phase 2 SDP evaluations and determined that a Phase 3 evaluation was required due to this issue being potentially greater than green. The Region III SRA determined that this finding was of very low safety significance because it did not represent an increase in the likelihood of a loss of cooling water initiating event due to different couplings being installed on the other cooling water pumps. The inspectors determined that this finding was cross-cutting in the Problem Identification and Resolution, Corrective Action Program area because the licensee did not use operating experience to support plant safety. Specifically, the licensee did not implement changes to the 121 motor driven cooling water pump after receiving and reviewing multiple pieces of operating experience regarding coupling failures due to hardness issues. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2010005 Section 4OA3 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | C Brown D Mcneil J Dalzell J Giessner K Stoedter L Kozak P Zurawski R Lerch |
| CCA | P.5, Operating Experience |
| INPO aspect | CL.1 |
| ' | |
Finding - Prairie Island - IR 05000282/2010005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2010Q4
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||