REGULATOR INFORMATION DISTRIBUTION STEM(RIDS)AUT~CURTISgN~'i'I~RECIP~NAMEACCESSION NBRt8007080213 DOC~DATE:80/07/03NOTARIZED!

NOFACIL:Susquehanna SteamElectricStation<UnitirPennsylva Susquehanna SteamElectricStationrUnit2iPennsylva AUTHORAFFILIATION Pennsylvania Po~erLLightCo,RECIPIENT AFFILIATION DOCKET¹0500038705000388

SUBJECT:

Supplcmentaldeficiency reptrePacificcheckvalves.Problemsw/checkvalveoperation inUnit1corespraypumpoischarge verticalpiperunwillnecessitate reworkofexistingbonnetstops,FinalreptwillbeprovidedbySeptDISTRIBUTION COOK:8001SCOPIESRECEIVED:1.TR QENCL+SIZE:TITLE:PSAR/FSAR AMOTSandRelatedCorr'espondence NOTESeSFA/3RECIPIENT IOCODE/NAME ACTION:AOI-lC8'h/$/A/G.LARrA<HBRoo]c',

WCOPIESLTTRENC11RECIPIENT LIOCODE/NAME BCyeuNr"Bc.ooo,B.PMSrWZ,8,.05COPIKSLTTRENCINTERNAL:

A/DCORE8CS13AUXSYSBR18CONTSYSBROIRrHUMFACSFYEFFTRSYSBRENVENGBRGEOSCIENBR09I8CSYSBR20KIRKWOODgR~29MECHKiNGBRNRCPOR02POLYERSYSBRQABR10REACSYSBRSITANALBR271111'11111141111111111ACCIDEVALBRCHEMENGBRCOREPERFBR17DIRECTORNRREMERG.PREP 22EQUIPQUALBRHYD/GEOBR11IEE06MATLENGBRMPAOELOPROC/TSTREVBRRAOASSESSBR12REGFILE011111113111111EXTERNAL:

ACRSNSIC30041011LPDR03JULl01980OTOTALNUMBEROFCOPIESREQUIRED:

LTTR51ENCL TWONORTHNINTHSTREET.ALLENTOWN, PA.18'101PHONE:(215)821-5151NORMANW.CURTISVicePrestrtent.Engineering

&Construction 821-5381July3,1980Mr.BoyceH.GrierDirector, RegionIU.S.NuclearRegulatory Commission 631ParkAvenueKingofPrussia,Pennsylvania 19406SUSQUEHANNA STEAMELECTRICSTATIONUPDATEINTHESTATUSOFADEFICIENCY ONPACIFICCHECKVALVESERs100450/100508 FILE840-4/900-10 PLA-502.

Reference:

PLA-466ofMarch31,1980

DearMr.Grier:

Thissupplements theabovereferenced correspondence andprovidesanupdateoftheinformation providedinourPLA-466.Unanticipated problemswithcheckvalveoperation intheUnitICoreSpraypumpdischarge verticalpiperunwillnecessitate reworkoftheexistingbonnetstops.BechtelNCR5913documents thislatestdiscrepancy.

TheoriginalproblemremainsopenunderMCAR1-47.WeexpecttoprovideafinalreporttotheCommission bySeptember, 1980.Verytrulyyours,N.W.CurtisVicePresident-Engineering aConstruction<<Nuclear FLWsjmkPs,aPENNSYLVANIA POWERILLIGHTCOMPANY8OOV080zi9 Mr.BoyceH.GrierJune27,1980cc:Mr.VictorStello(15)copiesDirectorWffice ofInspection 8Enforcement.

U.S.NuclearRegulatory Commission Washington, D.C.20555Mr.G.McDonald, Director(1)OfficeofManagement Information

&ProgramControlU.S.NuclearRegulatory Commission Washington, D.C.20555Mr.Robert,,M.

GalloU.S.NuclearRegulatory Commission P.O.Box52Shickshinny, Pennsylvania 1S655