Form APF-05-003-01, Rev. 2 DESIGN DOCUMENT CHANGE NOTICE INITIATING DOC.

TYPE: N/A NO. N/A DCP/CCP NO REV. 013979 ASSIGNED DISCIPLINE:

DESE DOCUMENT NUMBER E-1F9910 REV.

16 SEQ. NO.

01 PAGE 1 OF 4 OTHER DOCUMENTS AFFECTED BY THIS CHANGE:

E-15000, E-1F9905 OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE:

NONE DigsigCert 1.75 3.49 REASON FOR CHANGE:

Administrative change to reflect room number and/or room description changes within Access Control Area, Fire Area C-5 and C-6. No physical change to PFSSD cables. No change to Fire Area C-5 and C-6 boundaries. No impact to PFSSD Area Anlaysis.

Administrative change does not require PE Stamping per WCNOC-162 Paragraph 8.1.1 PREPARED BY:

DigsigOrg 4.5 DATE:

01/22/19 Verifier Qualification will be to the same requirement as the parent document VERIFIED BY:

DigsigVer 4.5 0.5 Kamran Derakhshandegan DATE:

1/24/2019 APPROVED BY:

DigsigApp 4.5 0.5 DATE:

02/04/2019 DC RELEASE:

DigsigDSR 4.5 0.65 DATE:

RPE Certification For ASME Section III design specifications, refer to AP 05-004 for qualification requirements DESCRIPTION OF CHANGE:

Room number and description changes impacted for Fire Area C-5 and C-6. See DDCN pages 2-4 for markup.

DC7 02/04/2019

Post Fire Safe Shutdown Area Analysis Fire Area C-5 E-1F9910, Rev. 13 Sheet C-5-3 of C-5-15 1.0 GENERAL AREA DESCRIPTION Fire area C-5 is located on the 1984 elevation of the Control Building and includes the rooms listed in Table C-5-1.

Table C-5-1 Rooms Located in Fire Area C-5 ROOM #

DESCRIPTION 3206 Corridor 3212 Womens Locker Room 3212A Partial Height Electrical Chase 3213 Womens Toilet 3214 Hall 3215 Mens Shower Room 3216 Drying Room 3217 Mens Toilet 3218 H.P. Office Area 3219 H.P. Office 3220 Sign In/Out Area 3221 Vestibule No. 1 3222 H.P. Office 3223 Janitors Closet 3224 Vestibule No. 2 NAC Area Above Suspended Ceiling Fire area C-5 is protected with an automatic wet-pipe sprinkler system above and below the suspended ceiling. In addition, partial automatic fire detection is installed. The fire area is separated from adjacent fire areas by minimum 3-hour fire resistant construction.

2.0 PRIMARY EQUIPMENT USED FOR PFSSD Table C-5-2 lists each system credited for post-fire safe shutdown and provides a discussion regarding the availability of the system to perform its Post Fire Safe Shutdown (PFSSD) function if a severe fire occurs in this area. For a summary of the area analysis results, see Section 8.0 of the Fire Area Analysis Narrative section.

RP Calibration LAB #2 HP Lounge HP Conference Room (West)

Women's Toilet 3231 Exit Monitor Area L

RCA Egress (Corridor)

DDCN E-1F9910-16-01 page 2 of 4

Post Fire Safe Shutdown Area Analysis Fire Area C-5 E-1F9910, Rev. 13 Sheet C-5-11 of C-5-15 Table C-5-4 PFSSD Cables Located in Fire Area C-5 Cable #

Location Primary PFSSD Equipment Cable Function (P) Power (C) Control (I) Instrumentation Evaluation Section Comments 11EFI11EA 3222, 3224, NAC EFFT0053 I

5.2.3 ESW Train A Flow Transmitter 11EFK01SB 3224, NAC DPEF01A C

5.2.3 Train A ESW Pump Control HIS and Interposing Relays 11EJB01AA NAC DPEJ01A P

5.2.5 Train A RHR Pump Motor 11GDG01AC 3212, 3224, NAC DCGD01A C

5.2.3 Train A ESW Pump Room Supply Fan Motor 11GDG01AD 3212, NAC DCGD01A C

5.2.3 Train A ESW Pump Room Supply Fan Motor 11GDI04AA 3224, NAC GDTE0001 I

5.2.3 Train A ESW Pump Room Temperature 11GDI04AB 3224, NAC GDTZ0001A I

5.2.3 Train A ESW Pump Room Inlet Damper 11GDI04AC 3224, NAC GDTZ0001B I

5.2.3 Train A ESW Pump Room Recirc Damper 11GDY01AA 3212, 3224, NAC DCGD01A C

5.2.3 Train A ESW Pump Room Supply Fan HIS and Interposing Relays 11GDY01AD 3212, NAC DCGD01A C

5.2.3 Train A ESW Pump Room Supply Fan HIS and Interposing Relays 11NGB10SB 3224, NAC NB00116 P

5.2.3 NG05E Feeder Breaker 11NGG01AA NAC XNG01 P

5.2.6 XNG01 Incoming Power Feed from NB0113 11NGG01AB NAC NG01A P

5.2.6 NG01A Incoming Power Feed from NG0106 11NGG01AC NAC NG01A P

5.2.6 NG01A Incoming Power Feed from NG0106 11NGG01BA NAC XNG03 P

5.2.6 XNG03 Incoming Power Feed from NB0110 11NGG01SA NAC XNG05 P

5.2.3 XNG05 Incoming Power from NB0116 15NBB03AA 3215, 3217, 3218, 3220, 3222, NAC NB01 P

5.2.4 Phase A Power Feed XNB01 to NB01 15NBB03AC 3215, 3217, 3218, 3220, 3222, NAC NB01 P

5.2.4 Phase B Power Feed XNB01 to NB01 15NBB03AE 3215, 3217, 3218, 3220, 3222, NAC NB01 P

5.2.4 Phase C Power Feed XNB01 to NB01 3216

3231, DDCN E-1F9910-16-01 page 3 of 4

Post Fire Safe Shutdown Area Analysis Fire Area C-6 E-1F9910, Rev. 13 Sheet C-6-3 of C-6-13 1.0 GENERAL AREA DESCRIPTION Fire area C-6 is located on the 1984 elevation of the Control Building and includes the rooms listed in Table C-6-1.

Table C-6-1 Rooms Located in Fire Area C-6 ROOM #

DESCRIPTION 3201 Stairway C-1 3202 Controlled H.P. Tool & Instrument Storage Room 3203 Hot Janitors Closet 3204 Corridor No. 1 3205 H.P. Area 3205A Partial Height Electrical Chase 3207 Exit Monitor Area 3208 Laundry Room 3209 Decon Area 3210 Decon Shower 3211 H.P. Area SAC Area Above Suspended Ceiling Fire area C-6 is protected with an automatic wet-pipe sprinkler system above and below the suspended ceiling. In addition, partial automatic fire detection is installed. The fire area is separated from adjacent fire areas by minimum 3-hour fire resistant construction.

2.0 PRIMARY EQUIPMENT USED FOR PFSSD Table C-6-2 lists each system credited for post-fire safe shutdown and provides a discussion regarding the availability of the system to perform its Post Fire Safe Shutdown (PFSSD) function if a severe fire occurs in this area. For a summary of the area analysis results, see Section 8.0 of the Fire Area Analysis Narrative section.

HP Conference Room (East)

RP Calibration Lab #1 RCA Ingress DDCN E-1F9910-16-01 page 4 of 4