Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 1 of 6 EQSD-II COVER SHEET

EQSD-II EQ PROGRAM MASTER LIST (Table 1)

Plus Mild Environment SR Electrical Equipment List (Table 2)

Revision History Revision Description 35 See Revision Summary

Prepared by: 12/12/23

Yasir Alobaidi Date:

Qualification Required: ES9280907

Verified by: 12/13/23 Brian Masters Date:

Qualification Required: ES9280907

Approved by: 12/14/23 John E. Ashley Date:

Document Service Release by:

Date:

Internal Use Only Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 2 of 6 EQSD-II COVER SHEET

EQSD-II R35 Revision

Description:

EQSD-II Change Notices Addressed:

EQSD Change Sequence Number Date Status EQSD-II-34-01 03/13/2023 Incorporate EQSD-II-34-02 04/12/2023 Incorporate EQSD-II-34-03 09/08/2023 Incorporate

Other Noted Revisions for R35:

Items Affected Reason for Change Changes Made EJZS8811A-E01, Drawings were reviewed and based on Per CN1, EJZS8811A-E01, and EJZS8811B-and this review it has been determined that E01 were deleted from Table 1.

EJZS8811B-E01 EJZS8811A and B limit switches do not use a Conax P/N N11007 as was previously identified. As a result, the complete line of information for EJZS8811A-E01 and B-E01 is deleted from the EQSD-II Table 1 with this change notice. The components do not need to be added to Table 2 since the subject parts do not exist.

ZZQ-1-EQ, PQE-E-01013-P08 supersedes PQE-E-Per CN2, Table 1, EQ Spec Column, EQ file ZZR-1-EQ, 01013-P01 thru P07 and P09. ZZQ number modified from E-01013-P01, E-01013-ZZW-1-EQ, EQ, ZZR-1-EQ, ZZW-1-EQ, P02, E-01013-P03, E-01013-P04, E-01013-ZZY-1-EQ, ZZY-1-EQ, ZZY-2-EQ, ZZY-3-EQ, ZZZ-P05, E-01013-P06, E-01013-P07, and E-ZZY-2-EQ, 1-EQ, ZZZ-2-EQ, and ZZZ-3-EQ are 01013-P09 to E-01013-P08 ZZY-3-EQ, now included in PQE-E-ZZZ-1-EQ, 01013-P08.

ZZZ-2-EQ, and ZZZ-3-EQ BBLT1311, BED of CR 10011316, Assignment Per CN3, Transmitters BBLT1311, BBLT1312, BBLT1312, 20033173, and calculation XX-55-001-BBLT1321, BBLT1322, BGFT0215B, BBLT1321, CN002 (also see EQSD-I), provide the GNPT0935, GNPT0936, GNPT0937, BBLT1322, necessary evaluation to show that each GNPT0938 and GNPT0939 moved from table 1 BGFT0215B, of the following components qualified in to table 2 and the LOCA Environment change GNPT0935, revision zero of this PQE due to from A to D.

GNPT0936, radiation during a LOCA DBA are no GNPT0937, longer in a harsh environment. The GNPT0938, and components addressed are BBLT1311, GNPT0939 BBLT1312, BBLT1321, BBLT1322, BGFT0215B, GNPT0935, GNPT0936, GNPT0937, GNPT0938 and GNPT0939.

The rooms these components are located are RM 1202, 1320, 1409 and 1410. The radiation dose for each of these components during a LOCA event has been confirmed to be less than 1.0E04 rads for 80 years. As identified in the identified BED WCAP 8587

Internal Use Only Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 3 of 6 EQSD-II COVER SHEET

Items Affected Reason for Change Changes Made determined that no deterioration in material structural properties is detectable at this dose, the transmitters can be removed. Based on this the identified components in is PQE are no longer required to be included in the EQ program.

Internal Use Only Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 4 of 6 EQSD-II COVER SHEET

EQSD-II Cover Sheet Instructions

1.0 PURPOSE The EQUIPMENT QUALIFICATION (EQ) MASTER LIST is Table 1 only. Table 1 is used to maintain a listing of components at WCGS that require EQ program documents to maintain qualification of the equipment. This list also identifies if there are any maintenance contingencies required to maintain the identified equipment qualification. It is noted that the Engineering Information System (EIS) and MPAC maintenance databases can be used to identify components that are in the EQ program.

Table 1:

This is the EQ program Master List. It identifies the safety related electrical components that are located in a harsh environment and are required to have an EQ program document. This table lists the equipment that is required to function during an accident and is identified as Category A or B in the LOCA/ HELB/ MSLB fields.

Table 2:

List of safety related electrical components that are either located in a mild environment or not required to function during a design bases accident (DBA). These components, while still needing to be qualified, are not required to have an EQ program file/ document. The equipment is identified as Category C or D in the LOCA/ HELB/ MSLB fields. In some cases, Category C is listed for what was ultimately determined to be a Category D mild environment. This Category C is maintained to retain the knowledge for breach door and/or future EQ related analysis.

Mechanical equipment that was originally in the EQ program and had MEQ type files with a HOT, COLD or BOTH shutdown function is also included.

2.0 FIELDS USED:

The underlined fields below are only used in Table 1. This additional information is not necessary for the equipment not required to have an EQ program document. The EQ program documents are either an Equipment Qualification Work Package (EQWP) or the new electronic version Plant Qualification Evaluation (PQE).

Component Number:

The number used to identify the equipment that is to be created, updated and deleted to track the EQ program activities.

Internal Use Only Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 5 of 6 EQSD-II COVER SHEET

MC: (Maintenance Contingency required)

This field provides information on if the identified EQSD-II master list Table 1 equipment requires any EQSD-III identified Table 1 or Table 2 activities. It also identifies any Table 1 equipment that does not require any EQ QL replacement based on the current plant life of 60 years. Components with no maintenance required can be either due to the QL being greater than 60 years or because the equipment has been replaced recently enough that it no longer needs to be replaced during the 60 -year plant life (Ref. QH-2020-2135 as one review and/or see MPAC). It is noted that QH-2020-2135 also provides a good reference for any equipment that may need to be replaced if the life of the plant is extended to 80 years. The following codes are used as applicable:

N - Qualified life (QL) is greater than 60 years, plus there is no EQSD-III Table 2 required activity.

N/Y2 - Qualified life (QL) is greater than 60 years, plus there is no EQSD-III Table 2 required activity, but on EQSD-III Table 2 with an EQ gasket or O-ring replacement requirement.

Y1 - Listed on EQSD -III on Table 1 with EQ QL requirement, but no EQSD -III Table 2 required activity.

Y1/2 - Listed on EQSD -III on Table 1 with an EQ QL requirement and on EQSD -III Table 2 with an EQ gasket or O -ring replacement requirement.

Note:

EIS does not allow the use of any codes other than No or Yes without a software change.

Therefore, when using EIS a No includes only the N code in the EQSD -II and Yes includes codes N/Y2, Y1 and Y1/2.

Equipment Qualification

Description:

The EQ description of the component. This may be different than the over all component description.

Installed Elevation:

Additional information on the location of the equipment. This includes the building, level and area (BLA) identifier to help locate the equipment.

EQ Room:

The room environment the equipment is installed in. Environmental conditions (temperature, pressure, humidity, radiation and flooding) are identified in EQSD-I, Attachment A and B.

EQ Spec:

On Table 1 the identified specification what is used to find the applicable EQWP or PQE program document. On Table 2 it is the associated specification that the equipment was bought to.

Model #:

The installed part number.

Manufacturer:

The name of the manufacture for the model number identified.

LOCA:

Describes the mode in which the component is to function when there is a loss of coolant accident.

HELB:

Describes the mode in which the component is to function when there is a high energy line break.

MSLB:

Describes the mode in which the component is to function when there is a main steam line break.

Internal Use Only Revision 35 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT Page 6 of 6 EQSD-II COVER SHEET

System:

The system the equipment is part of, for more detail on the system go to the system description.

HOT/ COLD:

HOT SHUTDOWN specifies that the component is required for hot shutdown.

COLD SHUTDOWN specifies that the component is required for cold shutdown.

Notes:

Specifies the number of the note at the end of the list that is related to the component.

3.0 EQSD-II, General Notes Section The notes in this section are applicable to both Table 1 and Table 2. It is noted that there are additional notes that are provided at the end of each table. Those notes are typically specific notes to the equipment for those tables.

General Notes Applicable to All of EQSD-II Tables 1 and 2:

A. The Hot and Cold Shutdown designations are based on a normal shutdown assuming a loss of offsite power and a safe shutdown earthquake. Components located in a harsh environment which are required for safe shutdown because of a LOCA, MSLB, or HELB are identified as Category A or B, except for mechanical equipment with a shutdown function listed as Category C or D listed in Table 2.

B. The normal and accident environment temperature, pressure, radiation, humidity and spray information can be found in EQSD-I Attachments A and B under the room number the equipment is located in.

C. A suffix (i.e. -E01 or -E02) has been added to some component numbers to allow additional EQ information related to the component to be listed in the table. This additional information may include subcomponents qualified to a different Equipment Qualification Work Package (EQWP) or, in some cases, identifies an approved alternative component (for example, a Barton and a Rosemount gauge approved for the identified component application).

Internal Use Only GENERAL Electrical Equipment Categories for LOCA/MSLB/HELB fields

Cat. A Item is required to function post accident Cat. B Item is not required to function post accident; however, item must not adversely fail post accident Cat. C Item's status post accident has no effect on plant safety Cat. D Item is in mild environment post accident

Notes: Description 2 Used throughout the plant.

3 The spent fuel pool cooling system will be operated during these conditions to maintain fuel pool temperatures.

4 This note identifies that Non-IE Conax modules used in this penetration and addressed in PQE-E-035B-P01 have a safety related function of maintaining the pressure boundary of containment. PQE-E-035B-P01 documents that Conax modules used in ZSE/ZSI222E (I), ZSE/ZSI252E (I), ZNE/ZNI253C (I), ZSE/ZSI254E (I), ZSE/ZSI255E (I), ZSE/ZSI255D (I),

ZNE/ZNI292F (I) and ZNE/ZNI294C (I) ZSE/ZSI222F (LVP), ZNE/ZNI224C (LVP), ZNE/ZNI274A (LVP), ZNE/ZNI274G (LVP) and ZNE/ZNI282C (LVP) are acceptable for use in the environments identified.

5 Used throughout the plant - outside containment.

7 Used inside containment.

8 Used throughout the plant with exception of instrumentation circuits inside containment and auxilary building rooms 1411, 1412, 1508, and 1509 9 Alternate EGS connector approved for installation per CP 12467 as necessary.

11 Determined by XX-81 analysis to be mild environment equipment post accident (also reference EQWP-J-605A R3) states that a location-specific dose calculation and analysis was performed on the butterfly valves located in Room 1314, and concluded that the subject valves can be recategorized as mild environment equipment. The parameters constitute a mild environment.

12 Determined by XX-53 analysis to be mild environment equipment post accident. EQWP-E-018 R5 states that a specific-location dose calculation and analysis was performed on the MCC's located in Room 1409 and 1410, and concluded that subject MCCs can be recategorized as a mild environment equipment.

16 Qualified as a sub-component of Panel RP209 17 Qualified as a sub-component of Panel RP330 18 Qualified as a sub-component of Panel RP332 19 Spared in Place 20 This equipment was added in response to NUREG-0737 Category II.B.1 21 This equipment was added in response to NUREG-0737 Category II.B.3 22 This equipment was added in response to NUREG-0737 Category II.D.3 24 This equipment was added in response to NUREG-0737 Category II.E.1.2 25 This equipment was added in response to NUREG-0737 Category II.F.1 26 This equipment was added in response to NUREG-0737 Category II.F.2 27 Rooms 1101, 1102, 1120, 1121, 1122 and 1130 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

  1. Internal Use Only 28 Rooms 1107 and 1108 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

29 Rooms 1113 and 1114 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

30 Rooms 1301, 1314, 1315 and 1320 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

31 Rooms 1508 and 1509 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

32 Rooms 1206 and 1207 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

33 Rooms 1401, 1402 and 1408 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

34 Rooms 1502, 1503, 1505 and 1507 plus Rooms 1504, 1506 and 1513 (due to transfer grill GLD0175 on M-1H1431) are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

35 Rooms 3401, 3406 and 3412 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

36 Rooms 6301 and 6302 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

37 Reference E-035B-00050, Table 3.1, Page 11. The power and control modules are ZSE/ZSI233E, ZSE/ZSI233F, ZSE/ZSI234F, ZNE/ZNI278F and ZNE/ZNI278G. The instrumentation modules are ZSE/ZSI233D, ZSE/ZSI233G, ZSE/ZSI234E, ZSE/ZSI243C, ZSE/ZSI249C, ZSE/ZSI249D, ZSE/ZSI250A, ZSE/ZSI250B, ZSE/ZSI250D, ZSE/ZSI250F, ZSE/ZSI250G, ZSE/ZSI258F, ZNE/ZNI277F, ZNE/ZNI278C, ZNE/ZNI278D, ZNE/ZNI278E, ZNE/ZNI279E, ZNE/ZNI287C, ZNE/ZNI287D, ZNE/ZNI287E, ZNE/ZNI288B, ZNE/ZNI288D, ZNE/ZNI288F, ZNE/ZNI295F and ZNE/ZNI295G.

38 GDI-30F (Long-glass, fiber filled, diallyl-phthalate) terminal blocks that are Series 601-JJ, 602-JJ, 604-JJ, 605-JJ, 812-JJ type are qualified under PQE-E-035B-P02 for each of these applications. Instrumentation applications do not use the Kulka terminal blocks inside the containment, PQE-E-11013-P01/ P06/P07/ P08/ P09 splices are used in these applications.

39 These assets contain two limit switches. However one of the limit switches is an installed spare and doesnt have power running to it. Therefore, doesnt perform any safety function and doesnt need qualified by the EQ program.

40 Not used

41 DRE 20217 approves changing the identified model 763 to 763A.

42 SWO 18-446734-002 changed model number to 763A.

43 PQE-ESE-43G-P01 44 CP 13788

45 CP 14701 50 Located in yard.

  1. Internal Use Only EQSD-II Rev. 35 EQSD-II Table 1: 1 of 50 EQ Harsh Environment Equipment List Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN 3XBM13 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0001) ELEV 2000-0 Ref. E-11012 3XBM14 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0002) ELEV 2000-0 Ref. E-11012 3XBM15 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0003) ELEV 2000-0 Ref. E-11012 3XBM16 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0004) ELEV 2000-0 Ref. E-11012 3XBM17 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0065) ELEV 2000-0 Ref. E-11012 3XBM18 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0066) ELEV 2000-0 Ref. E-11012 3XBM19 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0067) ELEV 2000-0 Ref. E-11012 3XBM20 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0068) ELEV 2000-0 Ref. E-11012 3XBM42 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0065/ 66/ 67/ 68) ELEV 2000-0 Ref. E-11012 3XBM43 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0065/ 66/ 67/ 68) ELEV 2000-0 Ref. E-11012 3XBM44 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0065/ 66/ 67/ 68) ELEV 2000-0 Ref. E-11012 3XBM45 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D BM BOTH 16 30 (BMHV0065/ 66/ 67/ 68) ELEV 2000-0 Ref. E-11012 3XEG20 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D EG BOTH 17 30 (EGTV0029) ELEV 2000-0 Ref. E-11012 3XEJ01 N EJHV0014 OPEN AND SEAL IN 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D EJ BOTH 16 30 AUX RELAY IN RP209 (EJHV0014) ELEV 2000-0 Ref. E-11012 3XEN03 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D EN BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGE05 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGE07 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGE09 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGE11 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGE13 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGE15 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 (GEHZ0101, 102, 103, 104) ELEV 2000-0 Ref. E-11012 3XGK16 N AUX RELAY PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GK BOTH 17 30 (SGK04A ) ELEV 2000-0 Ref. E-11012 3XGK17 N AUX RELAY PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GK BOTH 17 30 (SGK05A ) ELEV 2000-0 Ref. E-11012 3XGN03 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GN BOTH 17 30 ELEV 2000-0 Ref. E-11012 3XGN05 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GN BOTH 17 30 ELEV 2000-0 Ref. E-11012
  1. Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 2 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN 3XGN07 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GN BOTH 17 30 ELEV 2000-0 Ref. E-11012 3XGN09 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GN BOTH 17 30 ELEV 2000-0 Ref. E-11012 3XGS01 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS03 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS05 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS07 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS09 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS11 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS13 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS15 N AUX RELAY PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS17 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS19 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS21 N AUX RELAY IN PANEL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 16 30 ELEV 2000-0 Ref. E-11012 3XGS25 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS27 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS29 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS31 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS33 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS35 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS37 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS39 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS41 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS43 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS45 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XGS47 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012

2 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 3 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN 3XGS49 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GS BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XSJ01 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV006, 13, 19 ELEV 2000-0 Ref. E-11012 3XSJ03 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV0006 ELEV 2000-0 Ref. E-11012 3XSJ05 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV0006 ELEV 2000-0 Ref. E-11012 3XSJ07 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV0013 ELEV 2000-0 Ref. E-11012 3XSJ09 N 120 VAC AUX RELAY IN PANEL 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 RP209 FOR SJHV0013 ELEV 2000-0 Ref. E-11012 3XSJ11 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV0019 ELEV 2000-0 Ref. E-11012 3XSJ13 N 120 VAC AUX RELAY IN RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 16 30 FOR SJHV0019 ELEV 2000-0 Ref. E-11012 3XSJ25 N AUX RELAY IN PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XSJ27 N AUX RELAY IN PNL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XSJ29 N AUX RELAY IN PNL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 ELEV 2000-0 Ref. E-11012 3XSJ31 N 120 VAC AUX RELAY IN PANEL 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 RP332 FOR SJHV0128, 130 ELEV 2000-0 Ref. E-11012 3XSJ33 N 120 VAC AUX RELAY IN PANEL 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 RP332 FOR SJHV0128 ELEV 2000-0 Ref. E-11012 3XSJ35 N 120 VAC AUX RELAY IN PANEL 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D SJ BOTH 18 30 RP332 FOR SJHV0128 ELEV 2000-0 Ref. E-11012 62TDDAL1 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 237NE Struthers-Dunn A B D AL BOTH 18 30 ELEV 2000-0 Ref. E-11012 62TDEEN1 N AUX RELAY IN RP332 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EN BOTH 18 30 ELEV 2000-0 See E-11012 62TDEGN11 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EG BOTH 17 30 ELEV 2000-0 See E-11012 62TDEGN13 N AUX RELAY IN PANEL RP330 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EG BOTH 17 30 ELEV 2000-0 See E-11012 62TDENB01 N NB01 DEGRADED VOLTAGE TRIP 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EN BOTH 18 30 RELAY (NB0112) IN RP332 ELEV 2000-0 See E-11012 62TDENB02 N NB01 DEGRADED VOLTAGE TRIP 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EN BOTH 18 30 RELAY (NB0109) IN RP332 ELEV 2000-0 See E-11012 62TDENB05 N NB01 DEGRADED VOLTAGE 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EN BOTH 18 30 ANNUNCIATOR RELAY (NB0112) ELEV 2000-0 See E-11012 IN RP332 62TDENB06 N NB01 DEGRADED VOLTAGE 134 AUX BLDG/ 1320 E-093 236NE Struthers-Dunn A B D EN BOTH 18 30 ANNUNCIATOR RELAY (NB0109) ELEV 2000-0 See E-11012 IN RP332 94XAB05 N AUX RELAY IN PNL RP209 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D AB BOTH 16 30 ELEV 2000-0 Ref. E-11012 95XGE01 Y1 AUX RELAY PANEL RP330 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 17 30 (GEHZ0103) ELEV 2000-0 Ref. E-11012

3 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 4 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN 95XGE03 N AUX RELAY PANEL RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D GE BOTH 18 30 ELEV 2000-0 Ref. E-11012 95XKA004 N AUX RELAY IN RP332 134 AUX BLDG/ 1320 E-093 219NE Struthers-Dunn A B D KA BOTH 18 30 ELEV 2000-0 Ref. E-11012 ABHV0005-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)C D A AB BOTH ELEV 2026-0 ABHV0006-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)C D A AB BOTH ELEV 2026-0 ABHV0011-MV1 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 1

ABHV0011-MV2 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 2

ABHV0011-MV3 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 3

ABHV0011-MV4 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 4

ABHV0011-MV5 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 5

ABHV0011-MV6 Y1 LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 6

ABHV0014-MV1 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 1

ABHV0014-MV2 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 2

ABHV0014-MV3 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 3

ABHV0014-MV4 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 4

ABHV0014-MV5 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 5

ABHV0014-MV6 Y1 LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 6

ABHV0017-MV1 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 1

ABHV0017-MV2 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 2

4 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 5 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ABHV0017-MV3 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 3

ABHV0017-MV4 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 4

ABHV0017-MV5 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 5

ABHV0017-MV6 Y1 LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 6

ABHV0020-MV1 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 1

ABHV0020-MV2 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 2

ABHV0020-MV3 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 3

ABHV0020-MV4 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 4

ABHV0020-MV5 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 5

ABHV0020-MV6 Y1 LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/ 1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-ELEV 2026-0 6

ABHV0048-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)C D A AB BOTH ELEV 2026-0 ABHV0049-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)C D A AB BOTH ELEV 2026-0 ABHY0012A N ABHV0012 SOLENOID VALVE 145 AUX BLDG/ 1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0012A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1508 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0012A) ELEV 2026-0 ABHY0012B N ABHV0012 SOLENOID VALVE 145 AUX BLDG/ 1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0012B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1508 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0012B) ELEV 2026-0 ABHY0015A N ABHV0015 SOLENOID VALVE 145 AUX BLDG/ 1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0015A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1508 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0015A) ELEV 2026-0 ABHY0015B N ABHV0015 SOLENOID VALVE 145 AUX BLDG/ 1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0015B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1508 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0015B) ELEV 2026-0

5 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 6 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ABHY0018A N ABHV0018 SOLENOID VALVE 145 AUX BLDG/ 1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0018A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0018A) ELEV 2026-0 ABHY0018B N ABHV0018 SOLENOID VALVE 145 AUX BLDG/ 1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0018B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0018B) ELEV 2026-0 ABHY0021A N ABHV0021 SOLENOID VALVE 145 AUX BLDG/ 1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0021A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0021A) ELEV 2026-0 ABHY0021B N ABHV0021 SOLENOID VALVE 145 AUX BLDG/ 1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0021B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH 31 (ABZS0021B) ELEV 2026-0 ABLY0007A N ABLV0007 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0007A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH (ABLY0008B) ELEV 2026-0 ABLY0007B N ABLV0007 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0007B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH (ABLY0008A) ELEV 2026-0 ABLY0008A N ABLV0008 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0008B N ABLV0008 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0009A N ABLV0009 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0009A-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH (ABLY0010B) ELEV 2026-0 ABLY0009B N ABLV0009 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0009B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A AB BOTH (ABLY0010A) ELEV 2026-0 ABLY0010A N ABLV0010 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0010B N ABLV0010 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABPT0514 Y1/2 MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0515 Y1/2 MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0516 Y1/2 MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0524 Y1/2 MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/ 1412 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0525 Y1/2 MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/ 1412 ESE-1A 763A ITT Barton A D B AB BOTH 41 42 ELEV 2026-0

6 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 7 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ABPT0526 Y1/2 MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/ 1412 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0534 Y1/2 MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/ 1412 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0535 Y1/2 MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/ 1412 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0536 Y1/2 MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/ 1412 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0544 Y1/2 MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0545 Y1/2 MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPT0546 Y1/2 MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/ 1411 ESE-1A 763 ITT Barton A D B AB BOTH 41 ELEV 2026-0 ABPV0001-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1508 E-093-P03 NQB. 616822 Buchanan (Amerace)B D A AB BOTH 31 ELEV 2026-0 ABPV0002-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093-P03 NQB. 616822 Buchanan (Amerace)B D A AB BOTH 31 ELEV 2026-0 ABPV0003-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1509 E-093-P03 NQB. 616822 Buchanan (Amerace)B D A AB BOTH 31 ELEV 2026-0 ABPY0001 Y1 ABPV0001 I/P converter/ transducer145 AUX BLDG/ 1508J-601B 8005N Masoneilan B D A AB BOTH 31 ELEV 2026-0 ABPY0002 Y1 ABPV0002 I/P converter/ transducer145 AUX BLDG/ 1509J-601B 8005N Masoneilan B D A AB BOTH 31 ELEV 2026-0 ABPY0003 Y1 ABPV0003 I/P converter/ transducer145 AUX BLDG/ 1509J-601B 8005N Masoneilan B D A AB BOTH 31 ELEV 2026-0 ABPY0004 Y1 ABPV0004 I/P converter/ transducer145 AUX BLDG/ 1508J-601B 8005N Masoneilan B D A AB BOTH 31 ELEV 2026-0 ABZS0001 Y1/2 ABPV0001 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO B D A AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0002 Y1/2 ABPV0002 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO B D A AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0003 Y1/2 ABPV0003 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO B D A AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0004 Y1/2 ABPV0004 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO B D A AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0007A Y1/2 ABLV0007 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 EA180-12302 ABZS0007B Y1/2 ABLV0007 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 ABZS0008A Y1/2 ABLV0008 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 EA180-12302 ABZS0008B Y1/2 ABLV0008 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 ABZS0009A Y1/2 ABLV0009 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 EA180-12302 ABZS0009B Y1/2 ABLV0009 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 ABZS0010A Y1/2 ABLV0010 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 EA180-12302

7 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 8 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ABZS0010B Y1/2 ABLV0010 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C AB BOTH ELEV 2026-0 ABZS0012A Y1/2 ABHV0012 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0012B Y1/2 ABHV0012 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 ABZS0015A Y1/2 ABHV0015 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0015B Y1/2 ABHV0015 LIMIT SWITCH 145 AUX BLDG/ 1508 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 ABZS0018A Y1/2 ABHV0018 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0018B Y1/2 ABHV0018 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 ABZS0021A Y1/2 ABHV0021 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 EA180-12302 ABZS0021B Y1/2 ABHV0021 LIMIT SWITCH 145 AUX BLDG/ 1509 NAMCO EA180-11302 NAMCO A D C AB BOTH 31 ELEV 2026-0 AEFV0039-MV1 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-1 AEFV0039-MV2 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-2 AEFV0039-MV3 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-3 AEFV0039-MV4 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-4 AEFV0039-MV5 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-5 AEFV0039-MV6 Y1 LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-6 AEFV0040-MV1 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-1 AEFV0040-MV2 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-2 AEFV0040-MV3 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-3 AEFV0040-MV4 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-4 AEFV0040-MV5 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-5 8 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 9 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN AEFV0040-MV6 Y1 LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-6 AEFV0041-MV1 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-1 AEFV0041-MV2 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-2 AEFV0041-MV3 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-3 AEFV0041-MV4 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-4 AEFV0041-MV5 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-5 AEFV0041-MV6 Y1 LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/ 1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-6 AEFV0042-MV1 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-1 AEFV0042-MV2 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-2 AEFV0042-MV3 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-3 AEFV0042-MV4 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-4 AEFV0042-MV5 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-5 AEFV0042-MV6 Y1 LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/ 1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID ELEV 2026-0 VALVE MV-6 AELT0501 N/Y2 SG LEVEL WIDE RANGE LOOP 1 231 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH ELEV 1998-6 AELT0502 N/Y2 SG LEVEL WIDE RANGE LOOP 2 232 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH ELEV 1998-6 AELT0503 N/Y2 SG LEVEL WIDE RANGE LOOP 3 232 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH ELEV 1998-6 AELT0504 N/Y2 SG LEVEL WIDE RANGE LOOP 4 231 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH ELEV 1998-6 AELT0517 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH LOOP 1 ELEV 2026-0 AELT0518 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 1 ELEV 2026-0 9 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 10 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN AELT0519 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 1 ELEV 2026-0 AELT0527 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH LOOP 2 ELEV 2026-0 AELT0528 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 2 ELEV 2026-0 AELT0529 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 2 ELEV 2026-0 AELT0537 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 3 ELEV 2026-0 AELT0538 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 3 ELEV 2026-0 AELT0539 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 3 ELEV 2026-0 AELT0547 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 4 ELEV 2026-0 AELT0548 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 4 ELEV 2026-0 AELT0549 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH LOOP 4 ELEV 2026-0 AELT0551 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 1 ELEV 2026-0 AELT0552 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH LOOP 2 ELEV 2026-0 AELT0553 N/Y2 SG LEVEL NARROW RANGE 242 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH LOOP 3 ELEV 2026-0 AELT0554 N/Y2 SG LEVEL NARROW RANGE 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9 LOOP 4 ELEV 2026-0 BB004A N/Y2 TC REFERENCE JUNCTION BOX 251 RX BLDG/ 2000 ESE-44A WX-34794 Westinghouse A D A BB ---

ELEV 2047-6 BB004A-E01 N TC REFERENCE JUNCTION BOX 231 RX BLDG/ 2000 ESE-43G 4-Wire Cu Westinghouse A D A BB --- 43 SPLICES - RTD - (121JJ079) ELEV 1998-6 Wire/Brass at the reference junction box BB004A-E02 N/Y2 TC REFERENCE JUNCTION BOX 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB ---

SPLICES - THERMOCOUPLE ELEV 1998-6 cable assemblies Engineering BB004B N/Y2 TC REFERENCE JUNCTION BOX 251 RX BLDG/ 2000 ESE-44A WX-34794 Westinghouse A D A BB ---

ELEV 2047-6 BB004B-E01 N TC REFERENCE JUNCTION BOX 231 RX BLDG/ 2000 ESE-43G 4-Wire Cu Westinghouse A D A BB --- 43 SPLICES - RTD - (121JJ079) ELEV 1998-6 Wire/Brass at the reference junction box BB004B-E02 N/Y2 TC REFERENCE JUNCTION BOX 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB ---

SPLICES - THERMOCOUPLE ELEV 1998-6 cable assemblies Engineering BBFT0017 N/Y2 RCP 1A THRM BARR CLG FLOW 241 RX BLDG/ 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH ELEV 2026-0 BBFT0018 N/Y2 RCP 1B THRM BARR CLG FLOW 232 RX BLDG/ 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH ELEV 1998-6 BBFT0019 N/Y2 RCP 1C THRM BARR CLG FLOW 242 RX BLDG/ 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH ELEV 2026-0

10 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 11 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBFT0020 N/Y2 RCP 1D THRM BARR CLG FLOW 241 RX BLDG/ 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH ELEV 2026-0 BBHV0013 N RCP THERMAL BARRIER 2026' CTMT 2000 LIMITORQU SB-00 LIMITORQUE B D B BB BOTH COOLER ISOLATION VALVE BLDG E BBHV0014 N RCP THERMAL BARRIER 2000' CTMT 2000 LIMITORQU SB-00 LIMITORQUE B D B BB BOTH COOLER ISOLATION VALVE BLDG. E BBHV0015 N RCP THERMAL BARRIER 2026' CTMT 2000 LIMITORQU SB-00 LIMITORQUE B D B BB BOTH COOLER ISOLATION VALVE BLDG E BBHV0016 N RCP THERMAL BARRIER 232 RX BLDG/ 2000 LIMITORQU SB-00 LIMITORQUE B D B BB BOTH COOLER ISOLATION VALVE ELEV 1998-6 E BBHV8000A N PRESSURIZER PORV ISOLATION 261 RX BLDG/ 2601 LIMITORQU SB-00 LIMITORQUE A D A BB BOTH VALVE ELEV 2068-8 E BBHV8000B N PRESSURIZER PORV ISOLATION 261 RX BLDG/ 2601 LIMITORQU SB-00 LIMITORQUE A D A BB BOTH VALVE ELEV 2068-8 E BBHV8001A N/Y2 REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp. A D A BB COLD 20 VALVE ELEV 2047-6 BBHV8001A-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 J-603A-P04 N11085 Conax A D A BB COLD 20 VALVE CONNECTOR ELEV 2047-6 BBHV8001A-E02 N VALVE TERMINAL BOX 252 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB --- 20 ELEV 2047-6 Products BBHV8001B N/Y2 REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp. A D A BB COLD 20 VALVE ELEV 2047-6 BBHV8001B-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 J-603A-P04 N11085 Conax A D A BB COLD 20 VALVE CONNECTOR ELEV 2047-6 BBHV8001B-E02 N VALVE TERMINAL BOX 252 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB --- 20 ELEV 2047-6 Products BBHV8002A N/Y2 REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp. A D A BB COLD 20 VALVE ELEV 2047-6 BBHV8002A-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 J-603A-P04 N11085 Conax A D A BB COLD 20 VALVE CONNECTOR ELEV 2047-6 BBHV8002A-E02 N VALVE TERMINAL BOX 252 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB --- 20 ELEV 2047-6 Products BBHV8002B N/Y2 REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp. A D A BB COLD 20 VALVE ELEV 2047-6 BBHV8002B-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ 2000 J-603A-P04 N11085 Conax A D A BB COLD 20 VALVE CONNECTOR ELEV 2047-6 BBHV8002B-E02 N VALVE TERMINAL BOX 252 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB --- 20 ELEV 2047-6 Products BBHV8010A-E01 N VALVE TERMINAL BOX 261 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB BOTH ELEV 2068-8 Products BBHV8010B-E01 N VALVE TERMINAL BOX 261 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB BOTH ELEV 2068-8 Products BBHV8010C-E01 N VALVE TERMINAL BOX 261 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A BB BOTH ELEV 2068-8 Products BBHV8026-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A BB ---

ELEV 1998-6 JJ BBHV8027-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-035B 601-JJ, 602-JJ, 604-Kulka A D D BB ---

ELEV 2000-0 JJ BBHV8351A N RCP SEAL INJECTION 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D BB BOTH CONTAINMENT ISOLATION ELEV 2000-0 E VALVE 11 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 12 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBHV8351B N RCP SEAL INJECTION 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D BB BOTH CONTAINMENT ISOLATION ELEV 2000-0 E VALVE BBHV8351C N RCP SEAL INJECTION 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D BB BOTH CONTAINMENT ISOLATION ELEV 2000-0 E VALVE BBHV8351D N RCP SEAL INJECTION 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D BB BOTH CONTAINMENT ISOLATION ELEV 2000-0 E VALVE BBHY8026 N CONTAINMENT ISOL VALVE 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A BB ---

NITROGEN SUPPLY TO PRT ELEV 1998-6 BBHY8026-E01 N CONT ISOL VLV NITROGEN 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A BB ---

SUPPLY TO PRT CONNECTOR ELEV 1998-6 BBHY8027 N CONTAINMENT ISOL VALVE 133 AUX BLDG/ 1322 M-237 NPK831654E ASCO A D D BB ---

NITROGEN SUPPLY TO PRT ELEV 2000-0 BBLIS1311 Y1 RVLIS HYDRAULIC ISOLATOR 134 AUX BLDG/ 1323 ESE-49A 581-4 ITT Barton A D D BB --- 26 ELEV 2000-0 BBLIS1312 Y1 RVLIS HYDRAULIC ISOLATOR 134 AUX BLDG/ 1323 ESE-49A 581-4 ITT Barton A D D BB --- 26 ELEV 2000-0 BBLIS1321 Y1 RVLIS HYDRAULIC ISOLATOR 133 AUX BLDG/ 1322 ESE-49A 581-4 ITT Barton A D D BB --- 26 ELEV 2000-0 BBLIS1322 Y1 RVLIS HYDRAULIC ISOLATOR 133 AUX BLDG/ 1322 ESE-49A 581-4 ITT Barton A D D BB --- 26 ELEV 2000-0 BBLT0459 N/Y2 PRESSURIZER LEVEL 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A BB BOTH TRANSMITTER ELEV 2026-0 BBLT0460 N/Y2 PRESSURIZER LEVEL 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A BB BOTH TRANSMITTER ELEV 2026-0 BBLT0461 N/Y2 PRESSURIZER LEVEL 241 RX BLDG/ 2201 ESE-3A 764 ITT Barton A D A BB BOTH TRANSMITTER ELEV 2026-0 BBPCV0455A N/Y2 PRESSURIZER POWER 261 RX BLDG/ 2601 HE-9 3750014 Westinghouse/ A D A BB BOTH OPERATED RELIEF VALVE ELEV 2068-8 Garrett BBPCV0455A-E01 N PRESSURIZER POWER 241 RX BLDG/ 2601 J-603A-P04 N11007 Conax A D A BB BOTH OPERATED RELIEF VLV ELEV 2026-0 CONNECTOR BBPCV0455A-E02 N VALVE TERMINAL BOX 261 RX BLDG/ 2601 E-028 1600-NUC Marathon Special A D A BB BOTH ELEV 2068-8 Products BBPCV0456A N/Y2 PRESSURIZER POWER 261 RX BLDG/ 2601 HE-9 3750014 Westinghouse/ A D A BB BOTH OPERATED RELIEF VALVE ELEV 2068-8 Garrett BBPCV0456A-E01 N PRESSURIZER POWER 261 RX BLDG/ 2601 J-603A-P04 N11007 Conax A D A BB BOTH OPERATED RELIEF VLV ELEV 2068-8 CONNECTOR BBPCV0456A-E02 N VALVE TERMINAL BOX 261 RX BLDG/ 2601 E-028 1600-NUC Marathon Special A D A BB BOTH ELEV 2068-8 Products BBPT0403 N/Y2 REACTOR COOLANT SYSTEM 123 AUX BLDG/ 1202 ESE-1A 763 ITT Barton A A D BB BOTH 41 PRESSURE WIDE RANGE ELEV 1988-0 BBPT0405 N/Y2 REACTOR COOLANT SYSTEM 134 AUX BLDG/ 1320 ESE-1B 76PHSS Veritrak A A D BB BOTH 30 PRESSURE WIDE RANGE ELEV 2000-0 BBPT0406 N/Y2 REACTOR COOLANT SYSTEM 123 AUX BLDG/ 1202 ESE-1A 763 ITT Barton A A D BB BOTH 41 PRESSURE WIDE RANGE ELEV 1988-0 BBPT0455 Y1/2 PRESSURIZER PRESSURE 241 RX BLDG/ 2201 J-301 1154SH9RA Rosemount NuclearA D A BB BOTH TRANSMITTER ELEV 2026-0 12 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 13 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBPT0456 Y1/2 PRESSURIZER PRESSURE 241 RX BLDG/ 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITTER ELEV 2026-0 BBPT0457 Y1/2 PRESSURIZER PRESSURE 251 RX BLDG/ 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITTER ELEV 2047-6 BBPT0458 Y1/2 PRESSURIZER PRESSURE 251 RX BLDG/ 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITTER ELEV 2047-6 BBPV8702A N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 LIMITORQU SMB-2 LIMITORQUE C D A BB BOTH VALVE ELEV 1998-6 E BBPV8702B N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 LIMITORQU SMB-2 LIMITORQUE C D A BB BOTH VALVE ELEV 1998-6 E BBT/C0001 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0001-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0002 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0002-E01 N/Y2 THERMOCOUPLE CONNECTOR/ 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CABLE ASSEMBLIES ELEV 1998-6 cable assemblies Engineering BBT/C0003 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0003-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0004 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0004-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0005 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0005-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0006 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0006-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0007 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0007-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES 13 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 14 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBT/C0008 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0008-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0009 N RV CORE SUBCOOLING 241 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 2026-0 Inc.

THERMOCOUPLES BBT/C0009-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0010 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0010-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0012 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0012-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0013 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0013-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0014 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0014-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0015 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0015-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0017 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0017-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0018 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES 14 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 15 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBT/C0018-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0019 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0019-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0020 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0020-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0021 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0021-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0022 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0022-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0023 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0023-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0024 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0024-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0025 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0025-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0026 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0026-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES 15 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 16 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBT/C0027 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0027-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0028 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0028-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0029 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0029-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0030 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0030-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0031 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0031-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0032 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0032-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0033 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0033-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0034 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0034-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0036 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES 16 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 17 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBT/C0036-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0037 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0037-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0038 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0038-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0039 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0039-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0040 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0040-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0041 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0041-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0042 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0042-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0043 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0043-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0044 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0044-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES 17 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 18 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBT/C0045 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0045-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0046 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0046-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0047 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0047-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0048 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0048-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0049 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0049-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBT/C0050 N RV CORE SUBCOOLING 231 RX BLDG/ 2000 ESE-43A Type K Westinghouse/ CKB A D A BB --- 26 MONITOR INCORE ELEV 1998-6 Inc.

THERMOCOUPLES BBT/C0050-E01 N/Y2 THERMOCOUPLE 231 RX BLDG/ 2000 J-565 Mineral insulated Combustion A D A BB --- 26 CONNECTOR/CABLE ELEV 1998-6 cable assemblies Engineering ASSEMBLIES BBTE0410A1 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0410A2 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0410A3 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0410B N/Y2 RCS COLD LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0411A1 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 1 ELEV 1998-6 Co., Inc.

BBTE0411A2 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 1 ELEV 1998-6 Co., Inc.

BBTE0411A3 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 1 ELEV 1998-6 Co., Inc.

18 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 19 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBTE0411B N/Y2 RCS COLD LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 1 ELEV 1998-6 Co., Inc.

BBTE0413A N RCS HOT LEG TEMPERATURE 231 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH ELEMENT (WR) LOOP 1 ELEV 1998-6 BBTE0413A-E01 N RCS HOT LEG RTD CONNECTOR 231 RX BLDG/ 2201 J-603A-P04 N11007 Conax A D A BB BOTH (WR) LOOP 1 ELEV 1998-6 BBTE0413B N RCS COLD LEG TEMP ELEMENT 231 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH (WR) LOOP 1 ELEV 1998-6 BBTE0413B-E01 N RCS COLD LEG RTD 231 RX BLDG/ 2201 J-603A-P04 N11007 Conax A D A BB BOTH CONNECTOR (WR) LOOP 1 ELEV 1998-6 BBTE0420A1 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0420A2 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0420A3 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0420B N/Y2 RCS COLD LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0421A1 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 2 ELEV 1998-6 Co., Inc.

BBTE0421A2 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 2 ELEV 1998-6 Co., Inc.

BBTE0421A3 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 2 ELEV 1998-6 Co., Inc.

BBTE0421B N/Y2 RCS COLD LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 2 ELEV 1998-6 Co., Inc.

BBTE0423A N RCS HOT LEG TEMP ELEMENT 232 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH (WR) LOOP 2 ELEV 1998-6 BBTE0423A-E01 N RCS HOT LEG RTD CONNECTOR 232 RX BLDG/ 2201 J-603A-P04N11007 Conax A D A BB BOTH (WR) LOOP 2 ELEV 1998-6 BBTE0423B N RCS COLD LEG TEMP ELEMENT 232 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH (WR) LOOP 2 ELEV 1998-6 BBTE0423B-E01 N RCS COLD LEG RTD 232 RX BLDG/ 2201 J-603A-P04N11007 Conax A D A BB BOTH CONNECTOR (WR) LOOP 2 ELEV 1998-6 BBTE0430A1 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 3 ELEV 1998-6 Co., Inc.

BBTE0430A2 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0430A3 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0430B N/Y2 RCS COLD LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0431A1 N/Y2 RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB (INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0431A2 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 3 ELEV 1998-6 Co., Inc.

BBTE0431A3 N/Y2 RCS HOT LEG RTD TEMP 232 RX BLDG/ 2201 ESE-6 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 3 ELEV 1998-6 Co., Inc.

BBTE0431B N/Y2 RCS COLD LEG RTD TEMP 232 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 3 ELEV 1998-6 Co., Inc.

19 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 20 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBTE0433A N RCS HOT LEG TEMPERATURE 232 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH ELEMENT (WR) LOOP 3 ELEV 1998-6 BBTE0433A-E01 N RCS HOT LEG RTD CONNECTOR 232 RX BLDG/ 2201 J-603A-P04N11007 Conax A D A BB BOTH (WR) LOOP 3 ELEV 1998-6 BBTE0433B N RCS COLD LEG TEMPERATURE 232 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH ELEMENT (WR) LOOP 3 ELEV 1998-6 BBTE0433B-E01 N RCS COLD LEG RTD 232 RX BLDG/ 2201 J-603A-P04 N11007 Conax A D A BB BOTH CONNECTOR (WR) LOOP 3 ELEV 1998-6 BBTE0440A1 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0440A2 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0440A3 N/Y2 RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0440B N/Y2 RCS COLD LEG RTD TEMP ELE 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB ---

(INSTALLED SPARE) ELEV 1998-6 Co., Inc.

BBTE0441A1 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 4 ELEV 1998-6 Co., Inc.

BBTE0441A2 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 4 ELEV 1998-6 Co., Inc.

BBTE0441A3 N/Y2 RCS HOT LEG RTD TEMP 231 RX BLDG/ 2201 ESE-6 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 4 ELEV 1998-6 Co., Inc.

BBTE0441B N/Y2 RCS COLD LEG RTD TEMP 231 RX BLDG/ 2201 J-564 N9004E-2A-SP Weed Instrument C D A BB BOTH ELEMENT LOOP 4 ELEV 1998-6 Co., Inc.

BBTE0443A N RCS HOT LEG TEMPERATURE 231 RX BLDG/ 2201 J-564 21205 RDF Corp. A D A BB BOTH ELEMENT (WR) LOOP 4 ELEV 1998-6 BBTE0443A-E01 N RCS HOT LEG RTD CONNECTOR 231 RX BLDG/ 2201 J-603A-P04N11007 Conax A D A BB BOTH (WR) LOOP 4 ELEV 1998-6 BBTE0443B N RCS COLD LEG TEMPERATURE 231 RX BLDG/ 2201 ESE-6 21205 RDF Corp. A D A BB BOTH ELEMENT (WR) LOOP 4 ELEV 1998-6 BBTE0443B-E01 N RCS COLD LEG RTD 231 RX BLDG/ 2201 J-603A-P04N11007 Conax A D A BB BOTH CONNECTOR (WR) LOOP 4 ELEV 1998-6 BBTE1313 N RVLIS HEAD IMPULSE LINE 242 RX BLDG/ 2000 ESE-42A S8809 MINCO/ A D A BB --- 26 TEMP ELEMENT ELEV 2026-0 Westinghouse BBTE1314 N RVLIS HEAD IMPULSE LINE 242 RX BLDG/ 2000 ESE-42A S8809 MINCO/ A D A BB --- 26 TEMP ELEMENT ELEV 2026-0 Westinghouse BBTE1317 N RVLIS SEAL IMPULSE LINE TEMP 241 RX BLDG/ 2000 ESE-42A S8810 MINCO/ A D A BB --- 26 ELEMENT ELEV 2026-0 Westinghouse BBTE1318 N RVLIS SEAL IMPULSE LINE TEMP 241 RX BLDG/ 2000 ESE-42A S8810 MINCO/ A D A BB --- 26 ELEMENT ELEV 2026-0 Westinghouse BBTE1323 N RVLIS HEAD IMPULSE LINE 241 RX BLDG/ 2000 ESE-42A S8809 MINCO/ A D A BB --- 26 TEMP ELEMENT ELEV 2026-0 Westinghouse BBTE1324 N RVLIS HEAD IMPULSE LINE 241 RX BLDG/ 2000 ESE-42A S8809 MINCO/ A D A BB --- 26 TEMP ELEMENT ELEV 2026-0 Westinghouse BBTE1327 N RVLIS SEAL IMPULSE LINE TEMP 242 RX BLDG/ 2000 ESE-42A S8810 MINCO/ A D A BB --- 26 ELEMENT ELEV 2026-0 Westinghouse BBTE1328 N RVLIS SEAL IMPULSE LINE TEMP 242 RX BLDG/ 2000 ESE-42A S8810 MINCO/ A D A BB --- 26 ELEMENT ELEV 2026-0 Westinghouse BBTE1329 N RVLIS HEAD IMPULSE LINE 241 RX BLDG/ 2000 ESE-42A S8809 MINCO/ A D A BB --- 26 TEMP ELEMENT ELEV 2026-0 Westinghouse

20 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 21 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BBZS0455A N PRESSURIZER PORV LIMIT 261 RX BLDG/ 2601 HE-9 3760060 Westinghouse/ A D A BB BOTH 22 SWITCH ELEV 2068-8 Garrett BBZS0455A-E01 N PRESSURIZER PORV LIMIT 261 RX BLDG/ 2601 J-603A-P04N11007 Conax A D A BB BOTH 22 SWITCH CONNECTOR ELEV 2068-8 BBZS0456A N PRESSURIZER PORV LIMIT 261 RX BLDG/ 2601 HE-9 3760060 Westinghouse/ A D A BB BOTH 22 SWITCH ELEV 2068-8 Garrett BBZS0456A-E01 N PRESSURIZER PORV LIMIT 261 RX BLDG/ 2601 J-603A-P04N11007 Conax A D A BB BOTH 22 SWITCH CONNECTOR ELEV 2068-8 BBZS8010A N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 HE-7 65322 Westinghouse/ A D A BB BOTH 22 VALVE LIMIT SWITCH ELEV 2068-8 Garrett BBZS8010A-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 J-603A-P04 N11007 Conax A D A BB BOTH 22 VALVE LS CONNECTOR ELEV 2068-8 BBZS8010B N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 HE-7 65322 Westinghouse/ A D A BB BOTH 22 VALVE LIMIT SWITCH ELEV 2068-8 Garrett BBZS8010B-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 J-603A-P04 N11007 Conax A D A BB BOTH 22 VALVE LS CONNECTOR ELEV 2068-8 BBZS8010C N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 HE-7 65322 Westinghouse/ A D A BB BOTH 22 VALVE LIMIT SWITCH ELEV 2068-8 Garrett BBZS8010C-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ 2602 J-603A-P04 N11007 Conax A D A BB BOTH 22 VALVE LS CONNECTOR ELEV 2068-8 BBZS8026 N/Y2 CONTMN ISOL VLV NIT SUPPLY 231 RX BLDG/ 2000 HE-3/6 EA180-14303 NAMCO A D A BB ---

TO PRT LIMIT SWITCH ELEV 1998-6 EA180-15303 BBZS8026-E01 N CONT ISOL VLV NIT SUPPLY TO 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A BB ---

PRT LS CONNECTOR ELEV 1998-6 BBZS8027 N/Y2 CONTMN ISOL VLV NIT SUPPLY 231 RX BLDG/ 1322 HE-3/6 EA180-35303 NAMCO A D D BB ---

TO PRT LIMIT SWITCH ELEV 1998-6 EA180-34303 BBZS8702AA N/Y2 RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO C D A BB BOTH VALVE LIMIT SWITCH ELEV 1998-6 EA180-12303 BBZS8702AA-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-028 1600-NUC Marathon Special A D A BB BOTH (BBZS8702AB) ELEV 1998-6 Products BBZS8702AA-E02 N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax C D A BB BOTH VALVE LS CONNECTOR ELEV 1998-6 BBZS8702AB N/Y2 RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO C D A BB BOTH VALVE LIMIT SWITCH ELEV 1998-6 EA180-12303 BBZS8702AB-E01 N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax C D A BB BOTH VALVE LS CONNECTOR ELEV 1998-6 BGFT0215A Y1 RCP SEAL INJECTION FLOW 123 AUX BLDG/ 1202 J-301 1153HB5RCN0012 Rosemount NuclearA C D BG BOTH TRANSMITTER ELEV 1988-0 BGFT0215B-E01 N RCP SEAL INJECTION FLOW 123 AUX BLDG/ 1202 J-301 1153HB5RC Rosemount NuclearA C D BG BOTH TRANSMITTER ELEV 1988-0 BGHV8100 N SEAL WATER RETURN 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D BG ---

CONTAINMENT ISOLATION ELEV 2000-0 E VALVE BGHV8105 N CHARGING LINE CONTAINMENT 134 AUX BLDG/ 1323 LIMITORQU SB-00 LIMITORQUE A D D BG BOTH ISOLATION VALVE ELEV 2000-0 E BGHV8106 N CHARGING LINE ISOLATION 134 AUX BLDG/ 1323 LIMITORQU SB-00 LIMITORQUE A D D BG BOTH VALVE ELEV 2000-0 E BGHV8110 N CCP A MINIFLOW ISOLATION 112 AUX BLDG/ 1114 LIMITORQU SMB-00 LIMITORQUE A D D BG BOTH 29 VALVE ELEV 1974-0 E BGHV8111 N CCP B MINIFLOW ISOLATION 111 AUX BLDG/ 1107 LIMITORQU SMB-00 LIMITORQUE A D D BG BOTH 28 VALVE ELEV 1974-0 E 21 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 22 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BGHV8112 N SEAL WATER RETURN 231 RX BLDG/ 2000 LIMITORQU SMB-00 LIMITORQUE A D A BG ---

CONTAINMENT ISOL VALVE ELEV 1998-6 E BGHV8152-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D BG ---

ELEV 2000-0 BGHV8153A N/Y2 EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 HE-10A (XR-5240) Target Rock Corp.C D B BG BOTH 45 ISOLATION VALVE ELEV 1998-6 BGHV8153A-E01 N EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax C D B BG BOTH ISOLATION VALVE CONNECTOR ELEV 1998-6 BGHV8153B N/Y2 EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp.C D B BG BOTH 45 ISOLATION VALVE ELEV 1998-6 BGHV8153B-E01 N EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax C D B BG BOTH ISOLATION VALVE CONNECTOR ELEV 1998-6 BGHV8154A N/Y2 EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 HE-10A 79AB-001BB Target Rock Corp.B D B BG BOTH 45 ISOLATION VALVE ELEV 1998-6 BGHV8154A-E01 N EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D B BG BOTH ISOLATION VALVE CONNECTOR ELEV 1998-6 BGHV8154B N/Y2 EXCESS LETDOWN/RCS 231 CTMT 2000 HE-10A 79AB-001BB Target Rock Corp.B D B BG BOTH 45 ISOLATION VALVE BLDG/ ELEV BGHV8154B-E01 N EXCESS LETDOWN/RCS 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D B BG BOTH ISOLATION VALVE CONNECTOR ELEV 1998-6 BGHV8160-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B-P02 601-JJ, 602-JJ, 604-Kulka A D A BG ---

ELEV 1998-6 JJ BGHY8152 Y1 LETDOWN CONTAINMENT 133 AUX BLDG/ 1322 M-237 NPK831654E ASCO (NE) A D D BG ---

ISOLATION VALVE (BGHV8152) ELEV 2000-0 BGHY8160 Y1 LETDOWN CONTAINMENT 231 RX BLDG/ 2000 M-237 NPK831654E ASCO (NE) A D A BG ---

ISOLATION VALVE ELEV 1998-6 BGHY8160-E01 N LETDOWN CONTAINMENT 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A BG ---

ISOLATION VALVE CONNECTOR ELEV 1998-6 BGLCV0112B N VCT ISOLATION VALVE FROM 132 AUX BLDG/ 1318 LIMITORQU SB-00 LIMITORQUE A C D BG BOTH CHARGING PUMP SUCTION ELEV 2000-0 E-P04 BGLCV0112C N VCT ISOLATION VALVE FROM 132 AUX BLDG/ 1318 LIMITORQU SB-00 LIMITORQUE A C D BG BOTH CHARGING PUMP SUCTION ELEV 2000-0 E-P04 BGZS8152 N/Y2 LETDOWN CONTAINMENT ISOL 133 AUX BLDG/ 1322 NAMCO EA180-11302 NAMCO A D D BG ---

VLV LMT SWITCH ELEV 2000-0 HE-3/6 EA180-12303 BGZS8160 N/Y2 LETDOWN CONTAINMENT ISOL 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D A BG ---

VLV LIMIT SWITCH ELEV 1998-6 EA180-12303 BGZS8160-E01 N LETDOWN CONTAINMENT ISOL 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A BG ---

VLV LS CONNECTOR ELEV 1998-6 BLHV8047-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D BL ---

ELEV 2000-0 BLHY8047 Y1 CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 M-237 NPK831654E ASCO (NE) A D D BL ---

VALVE ELEV 2000-0 BLZS8047 N/Y2 CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 HE-3/6 EA180-14303 NAMCO A D D BL ---

VALVE LIMIT SWITCH ELEV 2000-0 EA180-15303 BMHV0001-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT ELEV 2026-0 BMHV0002-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT (AEFV0044) ELEV 2026-0 BMHV0003-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT ELEV 2026-0

22 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 23 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BMHV0004-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT (AEFV0046) ELEV 2026-0 BMHY0001A Y1 BMHV0001 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0001B Y1 BMHV0001 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0001B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A BM BOTH (AEFV0043, BMZS0001B) ELEV 2026-0 BMHY0002A Y1 BMHV0002 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0002B Y1 BMHV0002 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0002B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT (BMZS0002B) ELEV 2026-0 BMHY0003A Y1 BMHV0003 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0003B Y1 BMHV0003 SOLENOID VALVE 145 AUX BLDG/ 1412 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0003B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1412 E-093 NQB. 616822 Buchanan (Amerace)A D A BM BOTH (AEFV0045, BMZS0003B) ELEV 2026-0 BMHY0004A Y1 BMHV0004 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0004B Y1 BMHV0004 SOLENOID VALVE 145 AUX BLDG/ 1411 M-237 NP8321A6E ASCO (NE) A D C BM HOT ELEV 2026-0 BMHY0004B-E01 N VALVE TERMINAL BOX 145 AUX BLDG/ 1411 E-093 NQB. 616822 Buchanan (Amerace)A D A BM HOT (BMZS0004B) ELEV 2026-0 BMZS0001A Y1/2 BMHV0001 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 EA180-12302 BMZS0001B Y1/2 BMHV0001 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 BMZS0002A Y1/2 BMHV0002 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 EA180-12302 BMZS0002B Y1/2 BMHV0002 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 BMZS0003A Y1/2 BMHV0003 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 EA180-12302 BMZS0003B Y1/2 BMHV0003 LIMIT SWITCH 145 AUX BLDG/ 1412 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 BMZS0004A Y1/2 BMHV0004 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 EA180-12302 BMZS0004B Y1/2 BMHV0004 LIMIT SWITCH 145 AUX BLDG/ 1411 NAMCO EA180-11302 NAMCO A D C BM HOT ELEV 2026-0 BNHCV8800A-E01 N VALVE TERMINAL BOX 121 AUX BLDG/ 1202 E-093 NQB. 616822 Buchanan (Amerace)A C D BN BOTH ELEV 1988-0 BNHCV8800B-E01 N VALVE TERMINAL BOX 121 AUX BLDG/ 1202 E-093 NQB. 616822 Buchanan (Amerace)A C D BN BOTH ELEV 1988-0 BNHV0003 N CONTAINMENT SPRAY PUMP 111 AUX BLDG/ 1110 LIMITORQU SMB-00 LIMITORQUE A D D BN ---

SUCTION ISO VALVE ELEV 1974-0 E BNHV0004 N CONTAINMENT SPRAY PUMP 112 AUX BLDG/ 1112 LIMITORQU SMB-00 LIMITORQUE A D D BN ---

SUCTION ISO VALVE ELEV 1974-0 E

23 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 24 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN BNHV8806A N SAFETY INJECTION PUMP RWST 112 AUX BLDG/ 1113 LIMITORQU SB-00 LIMITORQUE A D D BN --- 29 SUCTION VALVE ELEV 1974-0 E BNHV8806B N SAFETY INJECTION PUMP RWST 111 AUX BLDG/ 1108 LIMITORQU SB-00 LIMITORQUE A D D BN --- 28 SUCTION VALVE ELEV 1974-0 E BNHV8812A N RHR PUMP RWST SUCTION 112 AUX BLDG/ 1111 LIMITORQU SB-1 LIMITORQUE A D D BN COLD VALVE ELEV 1974-0 E BNHV8812B N RHR PUMP RWST SUCTION 111 AUX BLDG/ 1109 LIMITORQU SB-1 LIMITORQUE A D D BN COLD VALVE ELEV 1974-0 E BNHV8813 N ISOLATION VALVE FOR SI 111 AUX BLDG/ 1108 LIMITORQU SMB-00 LIMITORQUE A D D BN --- 28 PUMPS MIN RECIRCULATION ELEV 1974-0 E BNHY8800A N RWST ISOLATION VALVE FOR 121 AUX BLDG/ 1202 M-237 NP831655E ASCO A C D BN BOTH FUEL POOL CLEANUP PUMPS ELEV 1988-0 BNHY8800B N RWST ISOLATION VALVE FOR 121 AUX BLDG/ 1202 M-237 NP831655E ASCO A C D BN BOTH FUEL POOL CLEANUP PUMPS ELEV 1988-0 BNLCV0112D N CHARGING PUMP RWST 112 AUX BLDG/ 1114 LIMITORQU SB-00 LIMITORQUE A D D BN BOTH 29 SUCTION VALVE ELEV 1974-0 E BNLCV0112E N CHARGING PUMP RWST 111 AUX BLDG/ 1107 LIMITORQU SB-00 LIMITORQUE A D D BN BOTH 28 SUCTION VALVE ELEV 1974-0 E BNZS8800A N/Y2 RWST ISOL VLV FOR FUEL POOL 121 AUX BLDG/ 1202 NAMCO EA180-12302 NAMCO A C D BN COLD CLEANUP PUMPS LMT SW ELEV 1988-0 HE-3/6 EA180-11303 BNZS8800B N/Y2 RWST ISOL VLV FOR FUEL POOL 121 AUX BLDG/ 1202 NAMCO EA180-11302 NAMCO A C D BN COLD CLEANUP PUMPS LMT SW ELEV 1988-0 EA180-11302 BNZS8812AA N/Y2 RHR PUMP RWST SUCTION 112 AUX BLDG/ 1111 HE-3/6 EA180-12303 NAMCO A D D BN COLD 39 VALVE LIMIT SWITCH ELEV 1974-0 EA180-12303 BNZS8812BA N/Y2 RHR PUMP RWST SUCTION 111 AUX BLDG/ 1109 HE-3/6 EA180-12303 NAMCO A D D BN COLD 39 VALVE LIMIT SWITCH ELEV 1974-0 NAMCO (spare)

BNZS8813 N/Y2 ISOL VLV FOR SI PUMPS MIN. 111 AUX BLDG/ 1108 NAMCO EA180-21302 NAMCO A D D BN --- 28 RECIRC LIMIT SWITCH ELEV 1974-0 HE-3/6 EA180-21303 DPBG05A N CENTRIFUGAL CHARGING PUMP 112 AUX BLDG/ 1114 AE-2 FRAME-5808-P39 Westinghouse A D D BG BOTH 29 A MOTOR ELEV 1974-0 500 HP DPBG05A-E01 N CENTRIFUGAL CHARGING PUMP 112 AUX BLDG/ 1114 E-029-P02 DS-7445/ P/N Kerite/ EGS (option) ACD BG BOTH 29 A MOTOR TERMINATE KIT ELEV 1974-0 3.99.16-3x250MCM-HVNS DPBG05B N CENTRIFUGAL CHARGING PUMP 111 AUX BLDG/ 1107 AE-2 FRAME-5808-P39 Westinghouse A D D BG BOTH 28 B MOTOR ELEV 1974-0 500 HP DPBG05B-E01 N CENTRIFUGAL CHARGING PUMP 111 AUX BLDG/ 1107 E-029-P02 P/N 3.99.16-EGS A D D BG BOTH 28 B MOTOR TERMINATE KIT ELEV 1974-0 3x250MCM-HVNS DPEJ01A N RHR PUMP A MOTOR 112 AUX BLDG/ 1111 AE-2 FRAME-5808-P39 Westinghouse A D D EJ COLD ELEV 1974-0 500 HP DPEJ01A-E01 N RHR PUMP A MOTOR 112 AUX BLDG/ 1111 E-029-P02 P/N 3.99.16-EGS A D D EJ COLD TERMINATION KIT ELEV 1974-0 3x250MCM-HVNS DPEJ01B N RHR PUMP B MOTOR 111 AUX BLDG/ 1109 AE-2 FRAME-5808-P39 Westinghouse A D D EJ COLD ELEV 1974-0 500 HP DPEJ01B-E01 N RHR PUMP B MOTOR 111 AUX BLDG/ 1109 E-029-P02 P/N 3.99.16-EGS A D D EJ COLD TERMINATION KIT ELEV 1974-0 3x250MCM-HVNS DPEM01A N SI PUMP A MOTOR 112 AUX BLDG/ 1113 AE-2 LIFELINE D, FRAME Westinghouse A D D EM - 29 ELEV 1974-0 5808H DPEM01A-E01 N SI PUMP A MOTOR 112 AUX BLDG/ 1113 E-029-P02 P/N 3.99.16-EGS A D D EM --- 29 TERMINATION KIT ELEV 1974-0 3x250MCM-HVNS DPEM01B N SI PUMP B MOTOR 111 AUX BLDG/ 1108 AE-2 LIFELINE D, FRAME Westinghouse A D D EM - 28 ELEV 1974-0 5808H 24 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 25 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN DPEM01B-E01 N SI PUMP B MOTOR 111 AUX BLDG/ 1108 E-029-P02 P/N 3.99.16-EGS A D D EM --- 28 TERMINATION KIT ELEV 1974-0 3x250MCM-HVNS DPEN01A N CONTAINMENT SPRAY PUMP A 112 AUX BLDG/ 1112 M-088/AE Motor info on Westinghouse A D D EN ---

MOTOR ELEV 1974-0 P01 drawing M-088-00051 DPEN01A-E01 N CONTAINMENT SPRAY PUMP A 112 AUX BLDG/ 1112 E-029-P02 DS-7445/ P/N Kerite/ EGS (option) AD D EN ---

MOTOR TERMINATION KIT ELEV 1974-0 3.99.16-3x250MCM-HVNS DPEN01B N CONTAINMENT SPRAY PUMP B 112 AUX BLDG/ 1110 M-088/AE Motor info on Westinghouse A D D EN ---

MOTOR ELEV 1974-0 P01 drawing M-088-00051 DPEN01B-E01 N CONTAINMENT SPRAY PUMP B 112 AUX BLDG/ 1110 E-029-P02 DS-7445/ P/N Kerite/ EGS (option) AD D EN ---

MOTOR TERMINATION KIT ELEV 1974-0 3.99.16-3x250MCM-HVNS DSGL09A N SI PUMP ROOM COOLER MOTOR 112 AUX BLDG/ 1113 M-612 Lifeline T: Frame Westinghouse/ A D D GL --- 29 ELEV 1974-0 256T Carrier DSGL09B N SI PUMP ROOM COOLER MOTOR 111 AUX BLDG/ 1108 M-612 Lifeline T: Frame Westinghouse/ A D D GL --- 28 ELEV 1974-0 256T Carrier DSGL10A N RHR PUMP ROOM COOLER 112 AUX BLDG/ 1111 M-612 Lifeline T: Frame Westinghouse/ A D D GL COLD MOTOR ELEV 1974-0 256T Carrier DSGL10B N RHR PUMP ROOM COOLER 111 AUX BLDG/ 1109 M-612 Lifeline T: Frame Westinghouse/ A D D GL COLD MOTOR ELEV 1974-0 256T Carrier DSGL12A N CENT. CHARGING PUMP ROOM 112 AUX BLDG/ 1114 M-612 Lifeline T: Frame Westinghouse/ A D D GL BOTH 29 COOLER MOTOR ELEV 1974-0 256T Carrier DSGL12B N CENT. CHARGING PUMP ROOM 112 AUX BLDG/ 1107 M-612 Lifeline T: Frame Westinghouse/ A D D GL BOTH 28 COOLER MOTOR ELEV 1974-0 256T Carrier DSGL13A N CTMT. SPRAY PUMP ROOM 112 AUX BLDG/ 1112 M-612 Lifeline T: Frame Westinghouse/ A D D GL ---

COOLER MOTOR ELEV 1974-0 256T Carrier DSGL13B N CTMT. SPRAY PUMP ROOM 111 AUX BLDG/ 1110 M-612 Lifeline T: Frame Westinghouse/ A D D GL ---

COOLER MOTOR ELEV 1974-0 256T Carrier DSGL15A N PENETRATION ROOM COOLER 144 AUX BLDG/ 1410 M-612 Lifeline T: Frame Westinghouse/ A D D GL BOTH MOTOR ELEV 2026-0 258T Carrier DSGL15B N PENETRATION ROOM COOLER 143 AUX BLDG/ 1409 M-612 Lifeline T: Frame Westinghouse/ A D D GL BOTH MOTOR ELEV 2026-0 258T Carrier DSGN01A N CONTAINMENT COOLER FAN 262 RX BLDG/ 2000 M-620 600287-43 MOTOR, American Air Filter A D A GN BOTH MOTOR ELEV 2068-8 150/75 HP (Joy/Reliance)

NOMINAL, 460 VAC, 3 PHASE, 60 HZ, RELIANCE, 5005UCZ FRAME DSGN01B N CONTAINMENT COOLER FAN 262 RX BLDG/ 2000 M-620 600287-43 MOTOR, American Air Filter A D A GN BOTH MOTOR ELEV 2068-8 150/75 HP (Joy/Reliance)

NOMINAL, 460 VAC, 3 PHASE, 60 HZ, RELIANCE, 5005UCZ FRAME

25 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 26 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN DSGN01C N CONTAINMENT COOLER FAN 261 RX BLDG/ 2000 M-620 600287-43 MOTOR, American Air Filter AD A GN BOTH MOTOR ELEV 2068-8 150/75 HP (Joy/Reliance)

NOMINAL, 460 VAC, 3 PHASE, 60 HZ, RELIANCE, 5005UCZ FRAME DSGN01D N CONTAINMENT COOLER FAN 261 RX BLDG/ 2000 M-620 600287-43 MOTOR, American Air Filter AD A GN BOTH MOTOR ELEV 2068-8 150/75 HP (Joy/Reliance)

NOMINAL, 460 VAC, 3 PHASE, 60 HZ, RELIANCE, 5005UCZ FRAME EFHV0031 N CONTAINMENT COOLER 134 AUX BLDG/ 1323 LIMITORQU SMB-000 LIMITORQUE B D D EF BOTH ISOLATION VALVE ELEV 2000-0 E EFHV0032 N CONTAINMENT COOLER 133 AUX BLDG/ 1322 LIMITORQU SMB-000 LIMITORQUE B D D EF BOTH ISOLATION VALVE ELEV 2000-0 E EFHV0033 N CONTAINMENT COOLER 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE B D B EF BOTH ISOLATON VALVE ELEV 1998-6 E EFHV0034 N CONTAINMENT COOLER 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE B D B EF BOTH ISOLATION VALVE ELEV 1998-6 E EFHV0043-E01 N VALVE TERMINAL BOX 134 AUX BLDG/ 1320 E-093 NQB. 616822 Buchanan (Amerace)A A D EF BOTH 30 ELEV 2000-0 EFHV0044-E01 N VALVE TERMINAL BOX 134 AUX BLDG/ 1320 E-093 NQB. 616822 Buchanan (Amerace)A A D EF BOTH 30 ELEV 2000-0 EFHV0045 N CONTAINMENT COOLER 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE B B D EF BOTH ISOLATION VALVE ELEV 1998-6 E EFHV0046 N CONTAINMENT COOLER 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE B B D EF BOTH ISOLATION VALVE ELEV 1998-6 E EFHV0049 N CONTAINMENT COOLER 134 AUX BLDG/ 1323 LIMITORQU SMB-000 LIMITORQUE A D D EF BOTH ISOLATION VALVE ELEV 2000-0 E EFHV0050 N CONTAINMENT COOLER 133 AUX BLDG/ 1322 LIMITORQU SMB-000 LIMITORQUE A D D EF BOTH ISOLATION VALVE ELEV 2000-0 E EFHY0043 Y1 EFHV0043 SOLENOID VALVE 134 AUX BLDG/ 1320 M-237 NP8320A187E ASCO (NE) A A D EF BOTH 30 ELEV 2000-0 EFHY0044 Y1 EFHV0044 SOLENOID VALVE 134 AUX BLDG/ 1320 M-237 NP8320A187E ASCO (NE) A A D EF BOTH 30 ELEV 2000-0 EFPDT0043 Y1 ESW TO AIR COMPRESOR ISO 134 AUX BLDG/ 1320 J-301 1153DB6R Rosemount Nuclear A C D EF BOTH 30 ELEV 2000-0 EFPDT0044 Y1 ESW TO AIR COMPRESOR ISO 134 AUX BLDG/ 1320 J-301 1153DB6R Rosemount Nuclear A C D EF BOTH 30 ELEV 2000-0 EFZS0043 N/Y2 EFHV0043 LIMIT SWITCH 134 AUX BLDG/ 1320 NAMCO EA180-11302 NAMCO A A D EF BOTH 30 ELEV 2000-0 EA180-12302 EFZS0044 N/Y2 EFHV0044 LIMIT SWITCH 134 AUX BLDG/ 1320 NAMCO EA180-11302 NAMCO A A D EF BOTH 30 ELEV 2000-0 EA180-12302 EGFT0062 Y1 RCP THERMAL BARRIER (TOTAL) 134 AUX BLDG/ 1127 J-301 1153DB4R Rosemount Nuclear A D D EG BOTH OUTLET FLOW ELEV 2000-0 EGFT0128 Y1 CCW HX OUT TO RCP BY-PASS 134 AUX BLDG/ 1320 J-301 1153DB5R Rosemount Nuclear B C D EG BOTH 30 ELEV 2000-0 EGFT0129 Y1 CCW HX OUT TO RCP BY-PASS 134 AUX BLDG/ 1320 J-301 1153DB5R Rosemount Nuclear B C D EG BOTH 30 ELEV 2000-0

26 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 27 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EGHV0058 N RC PUMP CCW SUPPLY CONT 134 AUX BLDG/ 1323 LIMITORQU SB-0 LIMITORQUE A D D EG BOTH ISO ELEV 2000-0 E EGHV0059 N RC PUMP CCW RETURN CONT 134 AUX BLDG/ 1323 LIMITORQU SMB-0 LIMITORQUE A D D EG BOTH ISO ELEV 2000-0 E EGHV0060 N RC PUMP CCW RETURN CONT 231 RX BLDG/ 2000 LIMITORQU SMB-0 LIMITORQUE A D A EG BOTH ISO ELEV 1998-6 E EGHV0061 N CONT ISO VLV CCW RTN FROM 134 AUX BLDG/ 1323 LIMITORQU SMB-000 LIMITORQUE A D D EG BOTH RC PMP THER BARR ELEV 2000-0 E EGHV0062 N CONT ISO VLV CCW RTN FROM 231 RX BLDG/ 2000 LIMITORQU SMB-00 LIMITORQUE A D A EG BOTH RC PMP THER BARR ELEV 1998-6 E EGHV0071 N ISO VALVE CCW SUPPLY TO RC 134 AUX BLDG/ 1323 LIMITORQU SB-0 LIMITORQUE A D D EG BOTH PUMP ELEV 2000-0 E EJFCV0610 N RHR MINI FLOW ISOLATION 111 AUX BLDG/ 1111 LIMITORQU SMB-000 LIMITORQUE A D D EJ COLD VALVE LOOP A ELEV 1974-0 E EJFCV0611 N RHR MINI FLOW ISOLATION 111 AUX BLDG/ 1109 LIMITORQU SMB-000 LIMITORQUE A D D EJ COLD VALVE LOOP B ELEV 1974-0 E EJFIS0611 Y1 RHR PUMP B MIN. FLOW 131 AUX BLDG/ 1107 ESE-40A 581A-0 ITT Barton A D D EJ COLD 28 INDICATING SWITCH ELEV 2000-0 EJHCV8825-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A EJ ---

ELEV 1998-6 JJ EJHCV8890A-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A EJ COLD ELEV 1998-6 JJ EJHCV8890B-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A EJ COLD ELEV 1998-6 JJ EJHV0014 N RHR 1A TO NUC SAM SYS 132 AUX BLDG/ 1310 J-603A V52600-6040-7 Valcor EngineeringB D D EJ ---

ELEV 2000-0 EJHV0015 N RHR 1B TO NUC SAM SYS 131 AUX BLDG/ 1309 J-603A V52600-6040-7 Valcor EngineeringB D D EJ ---

ELEV 2000-0 EJHV8701A N RHR SHUTDOWN SUCTION LINE 231 RX BLDG/ 2000 LIMITORQU SMB-2 LIMITORQUE B D A EJ BOTH ISOLATION VALVE LOOP A ELEV 1998-6 E EJHV8701B N RHR SHUTDOWN SUCTION LINE 231 RX BLDG/ 2000 LIMITORQU SMB-2 LIMITORQUE B D A EJ BOTH ISOLATION VALVE LOOP B ELEV 1998-6 E EJHV8716A N RHR INJECTION BALANCE 132 AUX BLDG/ 1310 LIMITORQU SB-1 LIMITORQUE A D D EJ COLD LINE/HL FEED LINE VALVE ELEV 2000-0 E EJHV8716B N RHR INJECTION BALANCE 131 AUX BLDG/ 1309 LIMITORQU SB-1 LIMITORQUE A D D EJ COLD LINE/HL FEED LINE VALVE ELEV 2000-0 E EJHV8804A N RHR TO CHARGING SI PUMP 132 AUX BLDG/ 1310 LIMITORQU SB-00 LIMITORQUE A D D EJ COLD SUCTIONS ELEV 2000-0 E EJHV8804B N RHR TO CHARGING/SI PUMP 111 AUX BLDG/ 1108 LIMITORQU SB-00 LIMITORQUE A D D EJ COLD 28 SUCTIONS ELEV 1974-0 E EJHV8809A N RHR ISOL VALVE TO COLD LEG 134 AUX BLDG/ 1323 LIMITORQU SBD-3 LIMITORQUE A D D EJ COLD RCS LOOPS 1 AND 2 ELEV 2000-0 E EJHV8809B N RHR ISOL VALVE TO COLD LEG 133 AUX BLDG/ 1322 LIMITORQU SBD-3 LIMITORQUE A D D EJ COLD RCS LOOPS 3 AND 4 ELEV 2000-0 E EJHV8811A N CONT RECIRC SUMP ISOLATION 124 AUX BLDG/ 1204 LIMITORQU SB-1 LIMITORQUE A B D EJ COLD VALVE (ENCAPSULATED) ELEV 1988-0 E EJHV8811B N CONT RECIRC SUMP ISOLATION 123 AUX BLDG/ 1203 LIMITORQU SB-1 LIMITORQUE A B D EJ COLD VALVE (ENCAPSULATED) ELEV 1988-0 E EJHV8840 N RHR ISOL VALVE TO HOT LEGS 133 AUX BLDG/ 1322 LIMITORQU SBD-3 LIMITORQUE A D D EJ COLD RCS LOOPS 2 AND 3 ELEV 2000-0 E

27 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 28 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EJHY8825 N TEST LINE ISOL VLV HOT LEG 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A EJ ---

INJ LINE SOL ELEV 1998-6 EJHY8825-E01 N TEST LINE ISO VLV HOT LEG INJ 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EJ ---

LINE SOL CONNECTOR ELEV 1998-6 EJHY8890A N TEST LINE ISOLATION VALVE 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A EJ COLD COLD LEG INJ LINE SOL ELEV 1998-6 EJHY8890A-E01 N TEST LINE ISO VLV COLD LEG 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EJ COLD INJ LINE SOL CONNECTOR ELEV 1998-6 EJHY8890B N TEST LINE ISOLATION VALVE 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A EJ COLD COLD LEG INJ LINE SOL ELEV 1998-6 EJHY8890B-E01 N TEST LINE ISO VLV COLD LEG 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EJ COLD INJ LINE SOL CONNECTOR ELEV 1998-6 EJLT0007 Y1/2 CTMT RECIRC SUMP LEVEL REACTOR BLDG 2000 J-301 1154DP4RG Rosemount Nuclear A D C EJ --- 25 TRANSMITTER 2000' EL 90 DEG WEST OF N/S CENTER LINE EJLT0008 Y1/2 CTMT RECIRC SUMP LEVEL REACTOR BLDG 2000 J-301 1154DP4RG Rosemount Nuclear A D C EJ --- 25 TRANSMITTER 2000' EL 90 DEG WEST OF N/S CENTER LINE EJZS8701BA N/Y2 RHR SHUTDOWN SUCT LINE 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO B D A EJ BOTH ISOL VLV LOOP B LMT SW ELEV 1998-6 EA180-12303 EJZS8701BA-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-028 1600-NUC Marathon Special A D A EJ BOTH (EJZS8701BB) ELEV 1998-6 Products EJZS8701BA-E02 N RHR PUMP SUCT LINE ISOL VLV 231 RX BLDG/ 2000 J-603A-P04N11007 Conax B D A EJ BOTH LOOP B LS CONNECTOR ELEV 1998-6 EJZS8701BB N/Y2 RHR SHUTDOWN SUCT LINE 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO B D A EJ BOTH ISOL VLV LOOP B LMT SW ELEV 1998-6 EA180-12303 EJZS8701BB-E01 N RHR PUMP SUCT LINE ISOL VLV 231 RX BLDG/ 2000 J-603A-P04N11007 Conax B D A EJ BOTH LOOP B LS CONNECTOR ELEV 1998-6 EJZS8804A N/Y2 RHR TO CHARGING/SI PUMP 132 AUX BLDG/ 1310 HE-3/6 EA180-12303 NAMCO A D D EJ COLD 39 SUCTIONS LIMIT SWITCH ELEV 2000-0 NAMCO EA180-12302 EJZS8804BA N/Y2 RHR TO CHARGING/SI PUMP 111 AUX BLDG/ 1108 HE-3/6 EA180-12303 NAMCO A D D EJ COLD 28 SUCTIONS LIMIT SWITCH ELEV 1974-0 EA180-12303 39 EJZS8804BB N/Y2 RHR TO CHARGING/SI PUMP 111 AUX BLDG/ 1108 HE-3/6 EA180-12303 NAMCO A D D EJ COLD 28 SUCTIONS LIMIT SWITCH ELEV 1974-0 EA180-12303 39 EJZS8809AA N/Y2 RHR ISOL VLV TO COLD LEG 134 AUX BLDG/ 1323 HE-3/6 EA180-12303 NAMCO A D D EJ COLD RCS LOOPS 1&2 LIMIT SW ELEV 2000-0 EA180-12303 EJZS8809BA N/Y2 RHR ISOL VLV TO COLD LEG 133 AUX BLDG/ 1322 HE-3/6 EA180-12303 NAMCO A D D EJ COLD RCS LOOPS 3&4 LIMIT SW ELEV 2000-0 NAMCO EA180-12302 EJZS8811A N/Y2 CONT RECIRC SUMP ISOLATION 124 AUX BLDG/ 1204 HE-3/6 EA180-12303 NAMCO A B D EJ COLD 39 VALVE LIMIT SWITCH ELEV 1988-0 NAMCO (spare)

EJZS8811B N/Y2 CONT RECIRC SUMP ISOLATION 123 AUX BLDG/ 1203 NAMCO EA180-12303(spare)NAMCO A B D EJ COLD 39 VALVE LIMIT SWITCH ELEV 1988-0 HE-3/6 EA180-12302 EJZS8825 N/Y2 TEST LINE ISO VLV HOT LEG INJ 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D A EJ ---

LINE LIMIT SW ELEV 1998-6 EA180-12303 EJZS8825-E01 N TEST LINE ISO VLV HOT LEG INJ 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EJ ---

LINE LS CONNECTOR ELEV 1998-6 EJZS8840A N/Y2 RHR ISOL VLV TO HOT LEGS 133 AUX BLDG/ 1322 HE-3/6 EA180-12303 NAMCO A D D EJ COLD RCS LOOPS 2&3 LIMIT SW ELEV 2000-0 NAMCO EA180-12302

28 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 29 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EJZS8890A N/Y2 TEST LINE ISOL VLV COLD LEG 231 RX BLDG/ 2000 NAMCO EA180-11303 NAMCO A D A EJ COLD INJ LINE LIMIT SW ELEV 1998-6 EA180-12303 EJZS8890A-E01 N TEST LINE ISO VLV COLD LEG 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EJ COLD INJ LINE LS CONNECTOR ELEV 1998-6 EJZS8890B N/Y2 TEST LINE ISOL VLV COLD LEG 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D A EJ COLD INJ LINE LIMIT SW ELEV 1998-6 EA180-12303 EJZS8890B-E01 N TEST LINE ISO VLV COLD LEG 231 RX BLDG/ 2000 J-603A-P04EA180-12303 Conax A D A EJ COLD INJ LINE LS CONNECTOR ELEV 1998-6 N11007 EMHV8801A N BIT DISCHARGE VALVE TO RCS 134 AUX BLDG/ 1323 LIMITORQU SBD-00 LIMITORQUE A D D EM BOTH ELEV 2000-0 E EMHV8801B N BIT DISCHARGE VALVE TO RCS 134 AUX BLDG/ 1323 LIMITORQU SBD-00 LIMITORQUE A D D EM BOTH ELEV 2000-0 E EMHV8802A N SI PUMP A DISCHARGE VALVE 134 AUX BLDG/ 1323 LIMITORQU SBD-00 LIMITORQUE A D D EM ---

TO HOT LEGS 2 & 3 ELEV 2000-0 E EMHV8802B N SI PUMP B DISCHARGE VALVE 133 AUX BLDG/ 1322 LIMITORQU SBD-00 LIMITORQUE A D D EM ---

TO HOT LEGS 1 & 4 ELEV 2000-0 E EMHV8803A N CHARGING PUMP DISCHARGE 111 AUX BLDG/ 1126 LIMITORQU SBD-00 LIMITORQUE A D D EM BOTH VALVE TO BIT ELEV 1974-0 E EMHV8803B N CHARGING PUMP DISCHARGE 111 AUX BLDG/ 1126 LIMITORQU SBD-00 LIMITORQUE A D D EM BOTH VALVE TO BIT ELEV 1974-0 E EMHV8807A N RHR TO CVCS AND SI PUMPS 112 AUX BLDG/ 1113 LIMITORQU SB-00 LIMITORQUE A D D EM COLD 29 ISOL VALVE ELEV 1974-0 E EMHV8807B N RHR TO CVCS AND SI PUMPS 111 AUX BLDG/ 1108 LIMITORQU SB-00 LIMITORQUE A D D EM COLD 28 ISOL VALVE ELEV 1974-0 E EMHV8814A N ISOLATION VALVE MINIFLOW 112 AUX BLDG/ 1113 LIMITORQU SMB-00 LIMITORQUE A D D EM --- 29 LINE OF SI PUMP A ELEV 1974-0 E EMHV8814B N ISOLATION VALVE MINIFLOW 112 AUX BLDG/ 1113 LIMITORQU SMB-00 LIMITORQUE A D D EM --- 29 LINE OF SI PUMP B ELEV 1974-0 E EMHV8821A N SI PUMP A DISCHARGE VALVE 112 AUX BLDG/ 1113 LIMITORQU SB-00 LIMITORQUE A D D EM --- 29 TO RCS COLD LEGS ELEV 1974-0 E EMHV8821B N SI PUMP B DISCHARGE VALVE 111 AUX BLDG/ 1108 LIMITORQU SB-00 LIMITORQUE A D D EM --- 28 TO RCS COLD LEGS ELEV 1974-0 E EMHV8823-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D C EM ---

ELEV 1998-6 JJ EMHV8824-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D C EM ---

ELEV 1998-6 JJ EMHV8835 N SI PUMPS A & B DISCHARGE 133 AUX BLDG/ 1322 LIMITORQU SBD-00 LIMITORQUE A D D EM ---

VALVE TO RCS COLD LEGS ELEV 2000-0 E EMHV8843-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A EM BOTH ELEV 1998-6 JJ EMHV8871-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A EM ---

ELEV 1998-6 JJ EMHV8881-E01 N VALVE TERMINAL BOX 232 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D C EM ---

ELEV 1998-6 JJ EMHV8888-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D EM ---

ELEV 2000-0 EMHV8923A N RWST SUCTION VALVE TO SI 112 AUX BLDG/ 1113 LIMITORQU SB-00 LIMITORQUE A D D EM --- 29 PUMP A ELEV 1974-0 E EMHV8923B N RWST SUCTION VALVE TO SI 111 AUX BLDG/ 1108 LIMITORQU SB-00 LIMITORQUE A D D EM --- 28 PUMP B ELEV 1974-0 E

29 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 30 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EMHV8964-E01 N VALVE TERMINAL BOX 134 AUX BLDG/ 1323 E-093 NQB. 616822 Buchanan (Amerace)A D D EM ---

ELEV 2000-0 EMHY8823 N TESTLINE/CONTAINMENT ISOL 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D C EM ---

VALVE SI COLD LEGS ELEV 1998-6 EMHY8823-E01 N TEST LINE CONT ISOL VLV SI 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D C EM ---

COLD LEGS CONNECTOR ELEV 1998-6 EMHY8824 N TESTLINE/ CONTAINMENT ISOL 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D C EM ---

VLV RCS HOT LEGS 1 & 4 ELEV 1998-6 EMHY8824-E01 N TEST LINE CONT ISOL VLV RCS 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D C EM ---

HOT LEGS 1 & 4 CONNECTOR ELEV 1998-6 EMHY8843 N BIT TEST LINE AND 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A EM BOTH CONTAINMENT ISOLATION ELEV 1998-6 VALVE EMHY8843-E01 N BIT TEST LINE AND CONT ISOL 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EM BOTH VALVE CONNECTOR ELEV 1998-6 EMHY8871 N SI TESTLINE/CONTAINMENT 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A EM ---

ISOLATION VALVE ELEV 1998-6 EMHY8871-E01 N SI TEST LINE CONT ISOL VALVE 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EM ---

CONNECTOR ELEV 1998-6 EMHY8881 N TESTLINE/CONTAINMENT ISOL 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D C EM ---

VLV RCS HOT LEGS 2 & 3 ELEV 1998-6 EMHY8881-E01 N TEST LINE CONT ISOL VLV RCS 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D C EM ---

HOT LEGS 2 & 3 CONNECTOR ELEV 1998-6 EMHY8888 N ACC FILL LINE CONTAINMENT 133 AUX BLDG/ 1322 M-237 NP831655E ASCO A D D EM ---

ISO VALVE ELEV 2000-0 EMHY8964 N SI TESTLINE/CONTAINMENT 133 AUX BLDG/ 1323 M-237 NPK831654E ASCO A D D EM ---

ISOLATION VALVE ELEV 2000-0 EMZS8802AA N/Y2 SI PUMP A DISCH VLV TO HOT 134 AUX BLDG/ 1323 HE-3/6 EA180-12303 NAMCO A D D EM ---

LEGS 2&3 LIMIT SWITCH ELEV 2000-0 EA180-12303 EMZS8802BA N/Y2 SI PUMP B DISCH VLV TO HOT 133 AUX BLDG/ 1322 HE-3/6 EA180-12303 NAMCO A D D EM ---

LEGS 1&4 LIMIT SWITCH ELEV 2000-0 EA180-12303 EMZS8814A N/Y2 ISOL VLV MINIFLOW LINE OF SI 112 AUX BLDG/ 1113 HE-3/6 EA180-21303 NAMCO A D D EM --- 29 PUMP A LIMIT SWITCH ELEV 1974-0 EA180-21303 39 EMZS8814B N/Y2 ISOL VLV MINIFLOW LINE OF SI 112 AUX BLDG/ 1113 NAMCO EA180-21302 NAMCO A D D EM --- 29 PUMP B LIMIT SWITCH ELEV 1974-0 HE-3/6 EA180-21303 39 EMZS8823 N/Y2 TEST/LINE/CONTAINMENT ISOL 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D C EM ---

VLV SI COLD LEGS LMT SW ELEV 1998-6 EA180-12303 EMZS8823-E01 N TEST LINE CONT ISO VLV SI 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D C EM ---

COLD LEGS LS CONNECTOR ELEV 1998-6 EMZS8824 N/Y2 TESTLINE/CONT ISOL VLV RCS 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D C EM ---

HOT LEGS 1&4 LIMIT SW ELEV 1998-6 EA180-12303 EMZS8824-E01 N TEST LINE CONT ISO VLV HOT 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D C EM ---

LEGS 1 & 4 LS CONNECTOR ELEV 1998-6 EMZS8835A N/Y2 SI PMPS A&B DISCH VLV TO RCS 133 AUX BLDG/ 1322 HE-3/6 EA180-12303 NAMCO A D D EM ---

COLD LEGS LIMIT SW ELEV 2000-0 NAMCO EA180-12302 EMZS8843 Y1/2 BIT TESTLINE AND 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D A EM BOTH CONTAINMENT ISOL VLV LIMIT ELEV 1998-6 EA180-12303 SW EMZS8843-E01 N BIT TEST LINE CONT ISOL VLV 231 RX BLDG/ 2000 J-603A-P04N11007 Conax A D A EM BOTH LS CONNECTOR ELEV 1998-6

30 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 31 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EMZS8871 N/Y2 SI TESTLINE/CONTAINMENT 231 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D A EM ---

ISOL VALVE LIMIT SWITCH ELEV 1998-6 EA180-12303 EMZS8871-E01 N SI TEST LINE CONT ISOL VLV LS 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A EM ---

CONNECTOR ELEV 1998-6 EMZS8881 N/Y2 TESTLINE/CONT ISOL VLV RCS 232 RX BLDG/ 2000 HE-3/6 EA180-11303 NAMCO A D C EM ---

HOT LEGS 2&3 LIMIT SW ELEV 1998-6 NAMCO EA180-12303 EMZS8881-E01 N TEST LINE CONT ISO VLV HOT 232 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D C EM ---

LEGS 2 & 3 LS CONNECTOR ELEV 1998-6 EMZS8888 N/Y2 ACC FILL LINE CONTAINMENT 133 AUX BLDG/ 1322 HE-3/6 EA180-11303 NAMCO A D D EM ---

ISOL VLV LIMIT SWITCH ELEV 2000-0 NAMCO EA180-12302 EMZS8964 N/Y2 SI TESTLINE/CONTAINMENT 133 AUX BLDG/ 1323 NAMCO EA180-11302 NAMCO A D D EM ---

ISOL VALVE LIMIT SWITCH ELEV 2000-0 EA180-12302 ENHV0001 N CONTAINMENT ISOLATION 124 AUX BLDG/ 1204 LIMITORQU SMB-00 LIMITORQUE A C D EN ---

(ENCAPSULATED) ELEV 1988-0 E ENHV0006 N CONTAINMENT ISOLATION 134 AUX BLDG/ 1323 LIMITORQU SMB-00 LIMITORQUE A D D EN ---

ELEV 2000-0 E ENHV0007 N CONTAINMENT ISOLATION 123 AUX BLDG/ 1203 LIMITORQU SMB-00 LIMITORQUE A C D EN ---

(ENCAPSULATED) ELEV 1988-0 E ENHV0012 N CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 LIMITORQU SMB-00 LIMITORQUE A D D EN ---

ELEV 2000-0 E ENHV0015 N SPRAY ADD TANK TO SPRAY 132 AUX BLDG/ 1315 LIMITORQU SMB-00 LIMITORQUE A D D EN --- 30 ADD EDUCTOR ELEV 2000-0 E ENHV0016 N SPRAY ADD TANK TO SPRAY 132 AUX BLDG/ 1315 LIMITORQU SMB-00 LIMITORQUE A D D EN --- 30 ADD EDUCTOR ELEV 2000-0 E ENLT0015 Y1 CTMT SPRAY ADD TK LEVEL 132 AUX BLDG/ 1315 J-301 1153DB3RA Rosemount Nuclear A D D EN --- 30 ELEV 2000-0 ENLT0016 Y1 CTMT SPRAY ADD TK LEVEL 132 AUX BLDG/ 1315 J-301 1153DB3RA Rosemount Nuclear A D D EN --- 30 ELEV 2000-0 ENLT0017 Y1 SPRAY ADD TANK LEVEL 132 AUX BLDG/ 1315 J-301 1153DB5R Rosemount Nuclear A D D EN --- 30 ELEV 2000-0 ENLT0019 Y1 SPRAY ADD TANK LEVEL 132 AUX BLDG/ 1315 J-301 1153DB5R Rosemount Nuclear A D D EN --- 30 ELEV 2000-0 EPHV8808A N ACCUMULATOR TANK A 231 RX BLDG/ 2000 LIMITORQU SBD-3 LIMITORQUE C D A EP COLD ISOLATION VALVE ELEV 1998-6 E EPHV8808D N ACCUMULATOR TANK D 232 RX BLDG/ 2000 LIMITORQU SBD-3 LIMITORQUE C D A EP COLD ISOLATION VALVE ELEV 1998-6 E EPHV8880-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D EP ---

ELEV 2000-0 EPHV8950A N/Y2 ACCUMULATOR TANK A VENT 241 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950A-E01 N ACCUMULATOR TANK A VENT 241 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0 EPHV8950B N/Y2 ACCUMULATOR TANK B VENT 242 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950B-E01 N ACCUMULATOR TANK B VENT 242 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0 EPHV8950C N/Y2 ACCUMULATOR TANK B VENT 242 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950C-E01 N ACCUMULATOR TANK B VENT 242 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0

31 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 32 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN EPHV8950D N/Y2 ACCUMULATOR TANK C VENT 242 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950D-E01 N ACCUMULATOR TANK C VENT 242 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0 EPHV8950E N/Y2 ACCUMULATOR TANK C VENT 242 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950E-E01 N ACCUMULATOR TANK C VENT 242 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0 EPHV8950F N/Y2 ACCUMULATOR TANK D VENT 241 RX BLDG/ 2000 HE-10A 79AB-004-3 Target Rock Corp. B D A EP COLD 44 VALVE ELEV 2026-0 EPHV8950F-E01 N ACCUMULATOR TANK D VENT 241 RX BLDG/ 2000 J-603A-P04 N11007 Conax B D A EP COLD VALVE CONNECTOR ELEV 2026-0 EPHY8880 N N2 SUPPLY CONT ISOL VALVE 231 RX BLDG/ 1322 M-237 NP831655E ASCO A D D EP ---

ELEV 1998-6 EPZS8808AB N/Y2 ACCUMULATOR TANK A 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO A D A EP COLD ISOLATION VALVE LIMIT SWITCH ELEV 1998-6 EA180-12303 EPZS8808AB-E01 N ACCUMULATOR TANK A ISOL 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A EP COLD VLV LS CONNECTOR ELEV 1998-6 EPZS8808AB-E02 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A EP COLD ELEV 1998-6 Products EPZS8808DB N/Y2 ACCUMULATOR TANK D 231 RX BLDG/ 2000 HE-3/6 EA180-12303 NAMCO A D A EP COLD ISOLATION VALVE LIMIT SWITCH ELEV 1998-6 EA180-12303 EPZS8808DB-E01 N ACCUMULATOR TANK D ISOL 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A EP COLD VLV LS CONNECTOR ELEV 1998-6 EPZS8808DB-E02 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A EP COLD ELEV 1998-6 Products EPZS8880 N/Y2 N2 SUPPLY CONT ISOL VALVE 231 CTMT 1322 HE-3/6 EA180-11303 NAMCO A D D EP ---

LIMIT SWITCH BLDG/ ELEV EA180-12303 GEHZ0101 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GE --- 34 ACTUATOR - GED0047 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GEHZ0102 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GE --- 34 ACTUATOR - GED0046 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GFHZ0011 Y1 AUX BLDG ISO DAMPER 1122 GENERAL 1122 M-627A MAR-25 American Warming A C D GF --- 27 ACTUATOR - GFD0033 - ELEC FLOOR AREA and Ventilating (NO. 3) (Raymond Control Systems)

GFHZ0012 Y1 AUX BLDG ISO DAMPER 1122 GENERAL 1122 M-627A MAR-25 American Warming A C D GF --- 27 ACTUATOR - GFD0034 - ELEC FLOOR AREA and Ventilating (NO. 3) (Raymond Control Systems)

GFHZ0013 Y1 AUX BLDG ISO DAMPER 1122 GENERAL 1122 M-627A MAR-25 American Warming A C D GF --- 27 ACTUATOR - GFD0035 - ELEC FLOOR AREA and Ventilating (NO. 3) (Raymond Control Systems)

32 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 33 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN GFHZ0014 Y1 AUX BLDG ISO DAMPER 1122 GENERAL 1122 M-627A MAR-25 American Warming A C D GF --- 27 ACTUATOR - GFD0036 - ELEC FLOOR AREA and Ventilating (NO. 3) (Raymond Control Systems)

GFHZ0020 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GF --- 34 ACTUATOR - GFD0029 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GFHZ0021 Y1 AUX BLDG ISO DAMPER 1504 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GF --- 34 ACTUATOR - GFD0028 - ELEC EXH & MECH and Ventilating EQUIP RM B (Raymond Control Systems)

GFHZ0030A Y1 AUX BLDG ISO DAMPER 144 AUX BLDG/ 1410 M-627A MAR-25 American Warming A D D GF ---

ACTUATOR - GFD0066 - ELEC ELEV 2026-0 and Ventilating (Raymond Control Systems)

GFHZ0030B Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1127 M-627A MAR-25 American Warming A D D GF --- 31 ACTUATOR - GFD0062 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GFHZ0031A Y1 AUX BLDG ISO DAMPER 144 AUX BLDG/ 1410 M-627A MAR-25 American Warming A D D GF ---

ACTUATOR - GFD0065 - ELEC ELEV 2026-0 and Ventilating (Raymond Control Systems)

GFHZ0031B Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1127 M-627A MAR-25 American Warming A D D GF --- 31 ACTUATOR - GFD0063 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GKHY0184E Y1 GKHZ0184E SOLENOID VALVE 1506 CTMT PRG 1506 M-237 WPHCX8320A182E ASCO (NE) A D D GK --- 34 SPLY AIR HDLG UNIT RM A GKHZ0150 Y1 CTRL BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GK --- 34 ACTUATOR - GKD0129 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GKHZ0151 Y1 CTRL BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GK --- 34 ACTUATOR - GKD0128 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GKHZ0184E N CTRL BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A PAS-111 American Warming A D D GK --- 34 ACTUATOR - GKD0314 - PNEU SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GLHZ0013 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GL --- 34 ACTUATOR - GLD0046 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GLHZ0014 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GL --- 34 ACTUATOR - GLD0047 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems) 33 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 34 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN GLHZ0062 Y1 AUX BLDG ISO DAMPER 1507 1507 M-627A MAR-25 American Warming A D D GL --- 34 ACTUATOR - GLD0058 - ELEC PERSONNEL and Ventilating HATCH AREA (Raymond Control Systems)

GLHZ0069 Y1 AUX BLDG ISO DAMPER 1314 AUX BLDG/ 1314 M-627A MAR-25 American Warming A D D GL --- 30 ACTUATOR - GLD0030 - ELEC CORRIDOR NO. and Ventilating 3 OUTSIDE HMS (Raymond Control DOOR Systems)

GLHZ0070 Y1 AUX BLDG ISO DAMPER 1314 AUX BLDG/ 1314 M-627A MAR-25 American Warming A D D GL --- 30 ACTUATOR - GLD0031 - ELEC CORRIDOR NO. and Ventilating 3 OUTSIDE HMS (Raymond Control DOOR Systems)

GLHZ0071 Y1 AUX BLDG ISO DAMPER 1314 AUX BLDG/ 1314 M-627A MAR-25 American Warming A D D GL --- 30 ACTUATOR - GLD0032 - ELEC CORRIDOR NO. and Ventilating 3 OUTSIDE HMS (Raymond Control DOOR Systems)

GLHZ0072 Y1 AUX BLDG ISO DAMPER 1314 AUX BLDG/ 1314 M-627A MAR-25 American Warming A D D GL --- 30 ACTUATOR - GLD0033 - ELEC CORRIDOR NO. and Ventilating 3 OUTSIDE HMS (Raymond Control DOOR Systems)

GLHZ0085 Y1 AUX BLDG ISO DAMPER 1308 AUX BLDG/ 1307 M-627A MAR-25 American Warming A D D GL ---

ACTUATOR - GLD0132 - ELEC DEMIN ALLEY and Ventilating (Raymond Control Systems)

GLHZ0086 Y1 AUX BLDG ISO DAMPER 1308 AUX BLDG/ 1307 M-627A MAR-25 American Warming A D D GL ---

ACTUATOR - GLD0134 - ELEC DEMIN ALLEY and Ventilating (Raymond Control Systems)

GLHZ0087 Y1 AUX BLDG ISO DAMPER 1308 AUX BLDG/ 1308 M-627A MAR-25 American Warming A D D GL ---

ACTUATOR - GLD0133 - ELEC DEMIN ALLEY and Ventilating (Raymond Control Systems)

GLHZ0088 Y1 AUX BLDG ISO DAMPER 1308 AUX BLDG/ 1308 M-627A MAR-25 American Warming A D D GL ---

ACTUATOR - GLD0135 - ELEC DEMIN ALLEY and Ventilating (Raymond Control Systems)

GNTE0060 N/Y2 CTMT COOLER A TEMP 262 RX BLDG/ 2000 J-558B 611-1B-C-4-C-2-A2-Weed Instrument A D A GN BOTH ELEV 2068-8 0 Co., Inc.

GNTE0061 N/Y2 CTMT COOLER B TEMP 261 RX BLDG/ 2000 J-558B 611-1B-C-4-C-2-A2-Weed Instrument A D A GN BOTH ELEV 2068-8 0 Co., Inc.

GNTE0062 N/Y2 CTMT COOLER C TEMP 261 RX BLDG/ 2000 J-558B 611-1B-C-4-C-2-A2-Weed Instrument A D A GN BOTH ELEV 2068-8 0 Co., Inc.

GNTE0063 N/Y2 CTMT COOLER D TEMP 262 RX BLDG/ 2000 J-558B 611-1B-C-4-C-2-A2-Weed Instrument A D A GN BOTH ELEV 2068-8 0 Co., Inc.

GSHV0003 N HYDROGEN ANALYZER CTMT 2047 AUX BLDG 1507 J-603A V52600-5940-2 Valcor Engineering A D D GS --- 34 SAMPLE EAST OF RE-31 ABOUT 6' OFF OF THE FLOOR GSHV0004 N HYDROGEN ANALYZER CTMT 251 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor Engineering A D A GS ---

SAMPLE ELEV 2047-6

34 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 35 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN GSHV0005 N HYDROGEN ANALYZER CTMT 251 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

SAMPLE ELEV 2047-6 GSHV0008 N HYDROGEN ANAL SAMPLE 133 AUX BLDG/ 1322 J-603A V52660-5940-2 Valcor EngineeringA D D GS ---

RETURN TO CTMT ELEV 2000-0 GSHV0009 N HYDROGEN ANAL SAMPLE 242 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

RETURN TO CTMT ELEV 2026-0 GSHV0012 N HYDROGEN ANALYZER CTMT 2047 AUX BLDG 1506 J-603A V52660-5940-2 Valcor EngineeringA D D GS --- 34 SAMPLE NE OF RE-32 ABOUT 6' OFF OF THE FLOOR GSHV0013 N HYDROGEN ANALYZER CTMT 252 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

SAMPLE ELEV 2047-6 GSHV0014 N HYDROGEN ANALYZER CTMT 251 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

SAMPLE ELEV 2047-6 GSHV0017 N HYDROGEN ANAL SAMPLE 134 AUX BLDG/ 1323 J-603A V52660-5940-2 Valcor EngineeringA D D GS ---

RETURN TO CTMT ELEV 2000-0 GSHV0018 N HYDROGEN ANAL SAMP 242 RX BLDG/ 2000 J-603A V52660-5940-2A Valcor EngineeringA D A GS ---

RETURN TO CTMT ELEV 2026-0 GSHV0020 N CTMT ISO ON AUX BUILDING ESF 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE A A D GS ---

FILTERS INLET ELEV 1998-6 E GSHV0021 N CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 LIMITORQU SMB-000 LIMITORQUE A D D GS ---

ELEV 2000-0 E GSHV0030 N PASS ISOLATION 2047 AUX BLDG 1506 J-603A V52660-5940-2 Valcor EngineeringA D D GS --- 21 34 NE OF RE-32 ABOUT 6' OFF OF THE FLOOR GSHV0031 N CTMT ATM MONITOR ISOL 251 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

VALVE ELEV 2047-6 GSHV0032 N CTMT ATM MONITOR ISOL 154 AUX BLDG/ 1506 J-603A V52660-5940-2 Valcor EngineeringA D D GS --- 34 VALVE ELEV 2047-6 GSHV0033 N CTMT ATM MONITOR ISOL 133 AUX BLDG/ 1323 J-603A V52600-5940-2 Valcor EngineeringA D D GS ---

VALVE ELEV 2000-0 GSHV0034 N CTMT ATM MONITOR ISOL 231 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

VALVE ELEV 1998-6 GSHV0035 N PASS ISOLATION 251 RX BLDG/ 1507 J-603A V52600-5940-2 Valcor EngineeringA D D GS --- 21 34 ELEV 2047-6 GSHV0036 N CTMT ATM MONITOR ISOL 252 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

VALVE ELEV 2047-6 GSHV0037 N 2047 AUX BLDG EAST OF RE-31 153 AUX BLDG/ 1507 J-603A V52600-5940-2 Valcor EngineeringA D D GS --- 34 ABOUT 6' OFF OF THE FLOOR. ELEV 2047-6 GSHV0038 N CTMT ATM MONITOR ISOL 133 AUX BLDG/ 1322 J-603A V52600-5940-2 Valcor EngineeringA D D GS ---

VALVE ELEV 2000-0 GSHV0039 N CTMT ATM MONITOR ISOL 231 RX BLDG/ 2000 J-603A V52600-5940-2A Valcor EngineeringA D A GS ---

VALVE ELEV 1998-6 GTHY0004 N GTHZ0004 SOLENOID VALVE 154 AUX BLDG/ 1506 M-237 NP8320A185V ASCO A D D GT --- 34 ELEV 2047-6 GTHY0005 N GTHZ0005 SOLENOID VALVE 252 RX BLDG/ 2000 M-237 NP8320A185V ASCO (NDE) A D A GT ---

ELEV 2047-6 GTHY0006 N GTHZ0006 SOLENOID VALVE 154 AUX BLDG/ 1506 M-237 NP8320A185V ASCO A D D GT --- 34 ELEV 2047-6

35 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 36 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN GTHY0007 N GTHZ0007 SOLENOID VALVE 252 RX BLDG/ 2000 M-237 NP8320A185V ASCO (NDE) A D A GT ---

ELEV 2047-6 GTHY0008 N GTHZ0008 SOLENOID VALVE 252 RX BLDG/ 2000 M-237 NP8320A185V ASCO (NDE) A D A GT ---

ELEV 2047-6 GTHY0009 N GTHZ0009 SOLENOID VALVE 153 AUX BLDG/ 1507 M-237 NP8320A185V ASCO A D D GT --- 34 ELEV 2047-6 GTHY0011 N GTHZ0011 SOLENOID VALVE 252 RX BLDG/ 2000 M-237 NP8320A185V ASCO (NDE) A D A GT ---

ELEV 2047-6 GTHY0012 N GTHZ0012 SOLENOID VALVE 153 AUX BLDG/ 1507 M-237 NP8320A185V ASCO A D D GT --- 34 ELEV 2047-6 GTHZ0004 N CONTAINMENT ISOLATION 154 AUX BLDG/ 1506 M-237-P03 Scotchcast Brand 9 3M A D D GT --- 34 control valve conduit seal resin and ELEV 2047-6 (XR-5240) & EPDM terminal box conduit EPDM O-Ring GTHZ0005 N Fisher Butterfly control valve conduit 251 RX BLDG/ 2000M-237-P03 Scotchcast Brand 9 3M A D A GT --- 7 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0006 N Fisher Butterfly control valve conduit 154 AUX BLDG/ 1506M-237-P03Scotchcast Brand 9 3M A D D GT --- 34 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0007 N Fisher Butterfly control valve conduit 251 RX BLDG/ 2000M-237-P03 Scotchcast Brand 9 3M A D A GT --- 7 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0008 N Fisher Butterfly control valve conduit 251 RX BLDG/ 2000M-237-P03 Scotchcast Brand 9 3M A D A GT --- 7 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0009 N Fisher Butterfly control valve conduit 153 AUX BLDG/ 1507M-237-P03Scotchcast Brand 9 3M A D D GT --- 34 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0011 N Fisher Butterfly control valve conduit 251 RX BLDG/ 2000M-237-P03 Scotchcast Brand 9 3M A D A GT --- 7 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0012 N Fisher Butterfly control valve conduit 153 AUX BLDG/ 1507M-237-P03Scotchcast Brand 9 3M A D D GT --- 34 seal resin and terminal box conduit ELEV 2047-6 (XR-5240) & EPDM EPDM O-Ring GTHZ0026 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GT --- 34 ACTUATOR - GTD0009 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GTHZ0027 Y1 AUX BLDG ISO DAMPER 1506 CTMT PRG 1506 M-627A MAR-25 American Warming A D D GT --- 34 ACTUATOR - GTD0010 - ELEC SPLY AIR HDLG and Ventilating UNIT RM A (Raymond Control Systems)

GTRE0059 N CTMT HIGH RANGE AREA RADN 261 RX BLDG/ 2000 J-361A RD-23 General Atomic Co. A D A GT --- 25 MON ELEV 2068-8 GTRE0060 N CTMT HIGH RANGE AREA RADN 252 RX BLDG/ 2000 J-361A RD-23 General Atomic Co. A D A GT --- 25 MON ELEV 2047-6 GTZS0004 N/Y2 GTHZ0004 LIMIT SWITCH 154 AUX BLDG/ 1506 NAMCO EA180-32302 NAMCO A D D GT --- 34 ELEV 2047-6 EA180-31302 GTZS0005 Y1/2 GTHZ0005 LIMIT SWITCH 252 RX BLDG/ 2000 NAMCO EA180-32302 NAMCO A D A GT --- 7 ELEV 2047-6 EA180-31302

36 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 37 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN GTZS0006 N/Y2 GTHZ0006 LIMIT SWITCH 154 AUX BLDG/ 1506 NAMCO EA180-32302 NAMCO A D D GT --- 34 ELEV 2047-6 EA180-31302 GTZS0007 Y1/2 GTHZ0007 LIMIT SWITCH 252 RX BLDG/ 2000 NAMCO EA180-32302 NAMCO A D A GT --- 7 ELEV 2047-6 EA180-31302 GTZS0008 Y1/2 GTHZ0008 LIMIT SWITCH 252 RX BLDG/ 2000 NAMCO EA180-32302 NAMCO A D A GT --- 7 ELEV 2047-6 EA180-31302 GTZS0009 N/Y2 GTHZ0009 LIMIT SWITCH 153 AUX BLDG/ 1507 NAMCO EA180-32302 NAMCO A D D GT --- 34 ELEV 2047-6 EA180-31302 GTZS0011 Y1/2 GTHZ0011 LIMIT SWITCH 252 RX BLDG/ 2000 NAMCO EA180-32302 NAMCO A D A GT --- 7 ELEV 2047-6 EA180-31302 GTZS0012 N/Y2 GTHZ0012 LIMIT SWITCH 153 AUX BLDG/ 1507 NAMCO EA180-32302 NAMCO A D D GT --- 34 ELEV 2047-6 EA180-31302 HBHV7126-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-028 1600 NUC Marathon Special A D A HB ---

ELEV 1998-6 Products HBHV7136-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D HB ---

ELEV 2000-0 HBHV7150-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 1322 E-093 NQB. 616822 Buchanan (Amerace)A D D HB ---

ELEV 1998-6 HBHV7176-E01 N VALVE TERMINAL BOX 231 RX BLDG/ 2000 E-035B 601-JJ, 602-JJ, 604-Kulka A D A HB ---

ELEV 1998-6 JJ HBHY7126 N CONTAINMENT ISOLATION 231 RX BLDG/ 2000 M-237 NPK831654E ASCO A D A HB ---

VALVE ELEV 1998-6 HBHY7126-E01 N CONTAINMENT ISOLATION ROOM 2000 2000 J-603A-P04 N11007 Conax A D A HB ---

VALVE CONNECTOR HBHY7136 N CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 M-237 NPK831654E ASCO A D D HB ---

VALVE ELEV 2000-0 HBHY7150 N CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 M-237 NPK831654E ASCO A D D HB ---

VALVE ELEV 2000-0 HBHY7176 N CONTAINMENT ISOLATION ROOM 2000 2000 M-237 NPK831654E ASCO A D A HB ---

VALVE HBHY7176-E01 N CONTAINMENT ISOLATION ROOM 2000 2000 J-603A-P04 N11007 Conax A D A HB ---

VALVE CONNECTOR HBZS7126-E01 N CONTAINMENT ISOLATION 231 RX BLDG/ 2000 J-603A-P04 N11007 Conax A D A HB ---

VALVE LS CONNECTOR ELEV 1998-6 HBZS7176-E01 N CONTAINMENT ISOLATION 231 RX BLDG 2000 J-603A-P04 N11007 Conax A D A HB ---

VALVE LS CONNECTOR HBZS7126 N/Y2 CONTAINMENT ISOLATION 231 RX BLDG/ 2000 HE-3/6 EA180-14303 NAMCO A D A HB ---

VALVE LIMIT SWITCH ELEV 1998-6 EA180-15303 HBZS7136 N/Y2 CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 HE-3/6 EA180-14303 NAMCO A D D HB ---

VALVE LIMIT SWITCH ELEV 2000-0 EA180-15303 HBZS7150 N/Y2 CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 NAMCO EA180-34302 NAMCO A D D HB ---

VALVE LIMIT SWITCH ELEV 2000-0 EA180-35302 HBZS7176 N/Y2 CONTAINMENT ISOLATION 231 RX BLDG 2000 HE-3/6 EA180-14303 NAMCO A D A HB ---

VALVE LIMIT SWITCH EA180-15303 KAFV0029-E01 N VALVE TERMINAL BOX 132 AUX BLDG/ 1322 E-093-P03 NQB. 616822 Buchanan (Amerace)A D D KA ---

ELEV 2000-0 KAFY0029 Y1 KAFV0029 SOLENOID VALVE 133 AUX BLDG/ 1322 E-093 NP8320A187E ASCO (NE) A D D KA ---

ELEV 2000-0 KAHV0030 N HYDROGEN MAKEUP AIR 231 RX BLDG/ 2000 LIMITORQU SMB-000 LIMITORQUE A D C KA ---

SUPPLY VALVE ELEV 1998-6 E

37 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 38 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN KAZS0029 N/Y2 KAFV0029 LIMIT SWITCH 133 AUX BLDG/ 1322 NAMCO EA180-11302 NAMCO A D D KA ---

ELEV 2000-0 EA180-12302 KCHV0253 N CONTAINMENT ISOLATON VALVE 1322 PIPE 1322 LIMITORQU SMB-000 LIMITORQUE A D D KC ---

PENETRATION E ROOM B LFFV0095 N CONTAINMENT ISOLATON VALVE 231 RX BLDG/ 2000 LIMITORQU SMB-00 LIMITORQUE A D A LF ---

ELEV 1998-6 E LFFY0096A N LFFV0096 SOLENOID VALVE 133 AUX BLDG/ 1322 M-237 NP8321A6E ASCO A D D LF ---

ELEV 2000-0 LFFY0096A-E01 N VALVE TERMINAL BOX 133 AUX BLDG/ 1322 E-093-P03 NQB. 616822 Buchanan (Amerace)A D D LF ---

(LFZS0096B) ELEV 2000-0 LFHV0105 N ISOLATION VALVE 111 AUX BLDG/ 1101 LIMITORQU SMB-000 LIMITORQUE A C D LF --- 27 ELEV 1974-0 E LFHV0106 N ISOLATION VALVE 111 AUX BLDG/ 1101 LIMITORQU SMB-000 LIMITORQUE A C D LF --- 27 ELEV 1974-0 E LFLE0009A N CTMT NORMAL SUMP 232 RX BLDG/ 2000 J-481 XM-54852 TransAmerica A D C LF --- 25 ELEV 1998-6 Delaval Inc. GEMS Sensors Division LFLE0009B N CTMT NORMAL SUMP 232 RX BLDG/ 2000 J-481 XM-54853 TransAmerica A D C LF --- 25 ELEV 1998-6 Delaval Inc. GEMS Sensors Division LFLE0010A N CTMT NORMAL SUMP 231 RX BLDG/ 2000 J-481 XM-54852 TransAmerica A D C LF --- 25 ELEV 1998-6 Delaval Inc. GEMS Sensors Division LFLE0010B N CTMT NORMAL SUMP 231 RX BLDG/ 2000 J-481 XM-54853 TransAmerica A D C LF --- 25 ELEV 1998-6 Delaval Inc. GEMS Sensors Division LFLE0101A N RHR PMP ROOM LEAKAGE 111 AUX BLDG/ 1109 J-481 XM-54854 TransAmerica A D D LF COLD LEVEL ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0101B N RHR PMP ROOM LEAKAGE 111 AUX BLDG/ 1109 J-481 XM-54853 TransAmerica A D D LF COLD LEVEL ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0102A N RHR PMP ROOM LEAKAGE 112 AUX BLDG/ 1111 J-481 XM-54854 TransAmerica A D D LF COLD LEVEL ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0102B N RHR PMP ROOM LEAKAGE 112 AUX BLDG/ 1111 J-481 XM-54853 TransAmerica A D D LF COLD LEVEL ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0103A N AUX BLDG SUMP LEVEL 114 AUX BLDG/ 1121 J-481 XM-54854 TransAmerica A A D LF --- 27 ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0103B N AUX BLDG SUMP LEVEL 114 AUX BLDG/ 1121 J-481 XM-54853 TransAmerica A A D LF --- 27 ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0104A N AUX BLDG SUMP LEVEL 114 AUX BLDG/ 1121 J-481 XM-54854 TransAmerica A A D LF --- 27 ELEV 1974-0 Delaval Inc. GEMS Sensors Division LFLE0104B N AUX BLDG SUMP LEVEL 114 AUX BLDG/ 1121 J-481 XM-54853 TransAmerica A A D LF --- 27 ELEV 1974-0 Delaval Inc. GEMS Sensors Division 38 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 39 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN LFZS0096A N/Y2 LFFV0096 LIMIT SWITCH 133 AUX BLDG/ 1322 NAMCO EA180-11302 NAMCO A D D LF ---

ELEV 2000-0 LFZS0096B N/Y2 LFFV0096 LIMIT SWITCH 133 AUX BLDG/ 1322 NAMCO EA180-11302 NAMCO A D D LF ---

ELEV 2000-0 EA180-12302 RP209 N AUX RELAY RACK 134 AUX BLDG/ 1320 E-093 219NE Cegelec Automation A B D RP BOTH 30 ELEV 2000-0 Inc. (Comsip Customline Corp)/

Struthers-Dunn RP330 N REVERSE ISOL RELAY RACK 134 AUX BLDG/ 1320 E-093 219NE Cegelec Automation A B D RP BOTH 30 ELEV 2000-0 Inc. (Comsip Customline Corp)/

Struthers-Dunn RP332 N AUX. RELAY RACK 134 AUX BLDG/ 1320 E-093 219NE Cegelec Automation A B D RP BOTH 30 ELEV 2000-0 Inc. (Comsip Customline Corp)/

Struthers-Dunn SENE0060 N EX-CORE NEUTRON FLUX ROOM 2000 2000 J-364 200262-101 Gamma Metric A D A SE ---

DETECTOR SENE0061 N EX-CORE NEUTRON FLUX ROOM 2000 2000 J-364 200262-101 Gamma Metric A D A SE ---

DETECTOR SGS02A N H2 ANALYZER 154 AUX BLDG/ 1506 J-359 K-IV Comsip-Delphi Inc.A D D GS --- 34 ELEV 2047-6 SGS02B N H2 ANALYZER 153 AUX BLDG/ 1507 J-359 K-IV Comsip-Delphi Inc.A D D GS --- 34 ELEV 2047-6 SJHV0003 N HOT LEG LOOP 1 SAMPLE VALVE 231 RX BLDG/ 2000 J-603A V52600-5688-9 Valcor EngineeringA D A SJ --- 21 ELEV 1998-6 SJHV0004 N HOT LEG LOOP 3 SAMPLE VALVE 231 RX BLDG/ 2000 J-603A V526-5688-9 Valcor EngineeringA D A SJ --- 21 ELEV 1998-6 SJHV0005 N PASS CONTAINMENT ISOLATION 231 RX BLDG/ 2000 J-603A V526-5688-9 Valcor EngineeringA D A SJ --- 21 VALVE ELEV 1998-6 SJHV0006 N PASS CONTAINMENT ISOLATION 134 AUX BLDG/ 1323 J-603A V526-5688-6 Valcor EngineeringA D D SJ --- 21 VALVE ELEV 2000-0 SJHV0012 N PRESSURIZER VAPOR SPACE 231 RX BLDG/ 2000 J-603A V52600-6042-1A Valcor EngineeringA D A SJ --- 21 SAMPLE ISOLATION VALVE ELEV 1998-6 SJHV0013 N PRESSURIZER VAPOR SPACE 134 AUX BLDG/ 1323 J-603A V52600-6042-1 Valcor EngineeringA D D SJ --- 21 SAMPLE ISOLATION VALVE ELEV 2000-0 SJHV0018 N ACCUMULATOR SAMPLES CTMT 231 RX BLDG/ 2000 J-603A V52600-6040-7A Valcor EngineeringA D A SJ --- 21 ISOLATION VALVE ELEV 1998-6 SJHV0019 N ACCUMULATOR SAMPLES CTMT 134 AUX BLDG/ 1323 J-603A V52600-6040-7 Valcor EngineeringA D D SJ --- 21 ISOLATION VALVE ELEV 2000-0 SJHV0127 N PASS CONTAINMENT ISOLATION 134 AUX BLDG/ 1323 J-603A V526-5688-6 Valcor EngineeringA D D SJ --- 21 VALVE ELEV 2000-0 SJHV0128 N PASS CONTAINMENT ISOLATION 231 RX BLDG/ 2000 J-603A V526-5688-9 Valcor EngineeringA D A SJ --- 21 VALVE ELEV 1998-6 SJHV0129 N PASS CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 J-603A V526-5688-6 Valcor EngineeringA D D SJ --- 21 VALVE ELEV 2000-0 SJHV0130 N PASS CONTAINMENT ISOLATION 133 AUX BLDG/ 1322 J-603A V526-5688-6 Valcor EngineeringA D D SJ --- 21 VALVE ELEV 2000-0

39 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 40 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZNE-1-EQ N ELECTRICAL PENETRATION ROOM 1410 1410 E-035B Low Voltage Conax A D D XX BOTH 37, MODULES Power/Control/ 38 Instrumentation 7040-1000- (Kapton)

ZNE263(Spare) N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE264 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE265 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE267 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE268 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE269 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE271 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE272 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE274 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE275 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE276 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE277 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE278 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE279 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE280 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE281 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE282 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE283 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE284 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE285 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE287 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE288 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE289 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo) 40 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 41 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZNE290 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE291 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE292 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE293 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE294 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZNE295 N ELECTRICAL PENETRATION 144 AUX BLDG/ 1410 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNE296 N ELECTRICAL PENETRATION 124 AUX BLDG/ 1204 E-035 Low Voltage Amphenol (Bunker-A B D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZNE297 N ELECTRICAL PENETRATION 123 AUX BLDG/ 1203 E-035 Low Voltage Amphenol (Bunker-A B D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZNE298 N ELECTRICAL PENETRATION 124 AUX BLDG/ 1204 E-035 Low Voltage Amphenol (Bunker-A C D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZNI-1-EQ N ELECTRICAL PENETRATION ROOM 2000 2000 E-035B Low Voltage Conax A A D XX BOTH 37, MODULES Power/Control/ 38 Instrumentation 7040-1000- (Kapton)

ZNI263(Spare) N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI264 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI265 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI267 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI268 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI269 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI271 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI272 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI274 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI275 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1

41 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 42 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZNI276 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI277 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI278 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI279 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI280 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI281 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI282 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI283 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI284 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI285 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI287 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI288 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZNI289 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI290 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI291 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI292 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI293 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI294 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZNI295 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo) 42 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 43 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZNI296 N VALVE TERMINAL BOX 124 AUX BLDG/ 1204 E-035B 601-JJ, 602-JJ, 604-Kulka A B D XX COLD ELEV 1988-0 JJ ZNI297 N VALVE TERMINAL BOX 123 AUX BLDG/ 1203 E-035B 601-JJ, 602-JJ, 604-Kulka A B D XX COLD ELEV 1988-0 JJ ZNI298 N VALVE TERMINAL BOX 124 AUX BLDG/ 1204 E-035B 601-JJ, 602-JJ, 604-Kulka A C D XX ---

ELEV 1988-0 JJ ZSE-1-EQ N ELECTRICAL PENETRATION ROOM 1409 1409 E-035B Low Voltage Conax A D D XX BOTH 37, MODULES Power/Control/ 38 Instrumentation 7040-1000- (Kapton)

ZSE206(Spare) N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE207 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE208 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE210 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE215 N ELECTRICAL PENETRATION 124 AUX BLDG/ 1204 E-035 Low Voltage Amphenol (Bunker-A B D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZSE216 N ELECTRICAL PENETRATION 123 AUX BLDG/ 1203 E-035 Low Voltage Amphenol (Bunker-A B D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZSE217 N ELECTRICAL PENETRATION 123 AUX BLDG/ 1203 E-035 Low Voltage Amphenol (Bunker-A C D XX BOTH 38 ASSY (ENCAPSULATION) ELEV 1988-0 50027200 Ramo)

ZSE218 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE219 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE222 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE223 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE224 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE225 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE226 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE233 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE234 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE240 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE243 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE249 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSE250 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

43 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 44 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZSE251(Spare) N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE252 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE253 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE254 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE255 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY ELEV 2026-0 Ramo)

ZSE258 N ELECTRICAL PENETRATION 143 AUX BLDG/ 1409 E-035 Low Voltage Amphenol (Bunker-A D D XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI-1-EQ N ELECTRICAL PENETRATION ROOM 2000 2000 E-035B Low Voltage Conax A A D XX BOTH 37, MODULES Power/Control/ 38 Instrumentation 7040-1000- (Kapton)

ZSI206(Spare) N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI207 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI208 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI210 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI215 N VALVE TERMINAL BOX 124 AUX BLDG/ 1204 E-035B 601-JJ, 602-JJ, 604-Kulka A B D XX COLD ELEV 1988-0 JJ ZSI216 N VALVE TERMINAL BOX 123 AUX BLDG/ 1203 E-035B 601-JJ, 602-JJ, 604-Kulka A B D XX COLD ELEV 1988-0 JJ ZSI217 N VALVE TERMINAL BOX 123 AUX BLDG/ 1203 E-035B 601-JJ, 602-JJ, 604-Kulka A C D XX ---

ELEV 1988-0 JJ ZSI218 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI219 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI222 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI223 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI224 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI225 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1

44 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 45 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZSI226 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI233 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI234 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI240 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI243 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI249 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI250 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZSI251(Spare) N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI252 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI253 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI254 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI255 N ELECTRICAL PENETRATION 241 RX 2000 E-035 50027200 Amphenol (Bunker-B D B XX BOTH 4 ASSY PRESSURE BOUNDARY BLDG/ELEV Ramo) 2026-0 / AREA 1 ZSI258 N ELECTRICAL PENETRATION 241 RX BLDG/ 2000 E-035 Low Voltage Amphenol (Bunker-A D A XX BOTH 38 ASSY ELEV 2026-0 50027200 Ramo)

ZTB-1-EQ N TERMINAL BOXES (commodity item) 8 E-028-P01 1600 NUC Marathon Special A A A XX --- 8 Products ZTB-2-EQ N TERMINAL BOXES (commodity item) 2 E-093-P03 NQB. 616822 Buchanan (Amerace)A A A XX --- 2 ZTB-3-EQ N TERMINAL BOXES (commodity item) 8 E-035B-P02 601-JJ, 602-JJ, 604-Kulka A A A XX --- 8 JJ ZTB-4-EQ N Terminal Lugs or Terminal 2 - Used 2 E-093-P04 RAT-Series, RBT-Thomas & Betts A A A XX BOTH Connectors throughout the Series & RDT Series plant ZTB-5-EQ N TERMINAL BOXES (commodity item) 8 LIMITORQU Marathon 1600; Marathon A A A XX --- 8 E-P05 Buchanan 0222 and Buchanan (see P03 for 0524; General General Electric Marathon 300s)Electric EB-5 and EB-Curtis 25; Curtis Type "L ZZB-1-EQ N 5 KV POWER CABLES 5 - Used 5 E-029-P01 HTK/HTNs Type Kerite Company A D D XX BOTH throughout the plant - outside containment 45 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 46 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZZC-1-EQ N 600 VOLT COPPER CONTROL 2 - Used 2 E-057-P01 Chemically cross-Rockbestos A A A XX BOTH CABLE throughout the linked polyethylene Company/ Firewall III plant insulated Firewall III/

Insulation Formulation KXL760, KXL-760-5, KXL-7600, KXL-780 ZZC-2-EQ N 600 VOLT COPPER CONTROL 2 - Used 2 E-057A FR-EP Anaconda-Ericsson A A A XX BOTH CABLE throughout the Inc.

plant ZZC-3-EQ N 600 VOLT COPPER CONTROL 2 - Used 2 E-057B XLPE Brand-Rex A A A XX BOTH CABLE throughout the Company/XLPE plant N 600 VOLT FIRE-RESISTIVE 1402 CORRIDOR 2 E-057C Appendix R Meggitt Safety D D A XX BOTH CONTROL AND POWER CABLE NO. 1/141 AUX Systems, Inc.

ZZC-4-EQ BLDG AND 1501 CTRL RM A/C &

FILTRN UNITS RM B ZZE-1-EQ N/Y2 1/2, 3/4, 1-1/2 Inch Quick 2 - Used 2 E-103-P02 880701-1, 880702-EGS Corporation A A A XX BOTH Disconnect Electrical Connector throughout the 1B, 9139601-1, plant 913601-1B, 913602-1, 913602-1B ZZF-1-EQ N GTE Sylvania Fuse Block, Gould 2 - Used 2 E-093-P05 PFS-3322 GTE Sylvania, Gould A A A XX BOTH Fuse A6Y, General Electric Busbar throughout the Fuse A6Y & GE Standoff plant 796A526P4

ZZG-1-EQ N 600 VOLT POWER CABLE 2 - Used 2 E-058 Durasheath 'EP' Anaconda-Ericsson A A A XX BOTH throughout the Inc./Durasheath 'EP' plant ZZJ-1-EQ N 600 VOLT SHIELDED 2 - Used 2 E-062A Irradiation cross-Rockbestos A A A XX BOTH INSTRUMENTATION CABLE throughout the E-057-P02 linked polyethylene Company/ Firewall III plant insulated Firewall III/Insulation Formation KXL 760G (Originally EQWP-E-062A)

ZZJ-2-EQ N 600 VOLT SHIELDED 2 - Used 2 E-062 EPR-CSPE Boston Insulated A A A XX BOTH INSTRUMENTATION CABLE throughout the Wire and Cable plant Company ZZQ-1-EQ N NUCLEAR JACKET REPAIR TAPE 2 - Used 2 E-01013-P08 NJRT (old part #, Raychem A A A XX BOTH MATERIAL throughout the original material) plant ZZR-1-EQ N CABLE BREAKOUT KIT 2 - Used 2 E-01013-P08 NCBK, NCBX, NESK Raychem A A A XX BOTH MATERIAL throughout the (old part #, original plant material)

ZZS-1-EQ N 600 VOLT SHIELDED 2 - Used 2 E-062 EPR-CSPE Boston Insulated A A A XX BOTH INSTRUMENTATION CABLE throughout the Wire and Cable plant Company

46 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 47 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN ZZT-1-EQ N THERMOCOUPLE EXTENSION 2 - Used 2 E-061 EPDM Eaton Corp. (Samuel A A A XX BOTH CABLE throughout the Moore Operations) plant ZZU-1-EQ N 5 KV CABLE SPLICE MATERIAL 5 - Used 5 E-029 S-5NS-NUC-DISC Kerite Company A D D XX BOTH throughout the EQWP-E-and IT/OT-5NS-NUC plant - outside 029 Check containment sheet #2 ZZV-1-EQ N CABLE END SEAL, BREAKOUT, 2 - Used 2 E-01013 NCBK,NESK, NJRT, Raychem A A A XX BOTH STUB CONNECTION, throughout the P08 NMCK, NPKC, TRANSITION SPLICE KITS plant NPKP, NPKS, MATERIAL AND JACKET REPAIR NPKV, NPKX (new MATERIAL part #s & materials)

ZZV-2-EQ N THREAD SEALANT 2 - Used 2 E-103-P03 P-1 EGS Corporation A A A XX BOTH throughout the M-771-00454 plant (Test Report)

ZZW-1-EQ N NUCLEAR MOTOR CONNECTION 2 - Used 2 E-01013-P08 N-MCK (old part #, Raychem A A A XX BOTH KITS MATERIAL throughout the original material) plant ZZX-1-EQ N COAXIAL & TRIAXIAL CABLE 2 - Used 2 E-060 RG-11A/U, RG-58 Brand-Rex Company A A A XX BOTH throughout the C/U, RG-59 B/U (FR-plant XLPE)

ZZY-1-EQ N CABLE TERMINATION HEAT 2 - Used 2 E-01013-P08 WCSF-N (old part #, Raychem A A A XX BOTH SHRINK FLD SPLICING MATERIAL throughout the original material)

SYSTEM plant ZZY-2-EQ N HEAT SHRINK FLD. SPLICING 2 - Used 2 E-01013-P08 WCSF-N (new part # Raychem A A A XX BOTH SYSTEM MATERIAL throughout the & material) plant ZZY-3-EQ N SHIM STOCK MATERIAL 2 - Used 2 E-01013-P08 WCSF-N-050 (old Raychem A A A XX BOTH throughout the part #, original plant material)

ZZZ-1-EQ N STUB CONNECTION KIT 2 - Used 2 E-01013-P08 NPKV (old part #, Raychem A A A XX BOTH MATERIAL throughout the original material) plant ZZZ-2-EQ N IN-LINE BOLTED CONNNECTION 2 - Used 2 E-01013-P08 WCSF-N (old part #, Raychem A A A XX BOTH MATERIAL throughout the original material) plant ZZZ-3-EQ N TRANSITION SPLICE KIT 2 - Used 2 E-01013-P08 NPKS, NPKC, Raychem A A A XX BOTH MATERIAL throughout the NPKP, NPKX (old plant part #, original material)

GENERAL Electrical Equipment Categories for LOCA/MSLB/HELB fields

Cat. A Item is required to function post accident Cat. B Item is not required to function post accident; however, item must not adversely fail post accident Cat. C Item's status post accident has no effect on plant safety Cat. D Item is in mild environment post accident 47 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 48 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN

48 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 49 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT DOWN Notes: Description 2 Used throughout the plant.

3 The spent fuel pool cooling system will be operated during these conditions to maintain fuel pool temperatures.

4 This note identifies that Non-IE Conax modules used in this penetration and addressed in PQE-E-035B-P01 have a safety related function of maintaining the pressure boundary of containment. PQE-E-035B-P01 documents that Conax modules used in ZSE/ZSI222E (I), ZSE/ZSI252E (I), ZNE/ZNI253C (I), ZSE/ZSI254E (I),

ZSE/ZSI255E (I), ZSE/ZSI255D (I), ZNE/ZNI292F (I) and ZNE/ZNI294C (I) ZSE/ZSI222F (LVP), ZNE/ZNI224C (LVP), ZNE/ZNI274A (LVP), ZNE/ZNI274G (LVP) and ZNE/ZNI282C (LVP) are acceptable for use in the environments identified.

5 Used throughout the plant - outside containment.

7 Used inside containment.

8 Used throughout the plant with exception of instrumentation circuits inside containment and auxilary building rooms 1411, 1412, 1508, and 1509 9 Alternate EGS connector approved for installation per CP 12467 as necessary.

11 Determined by XX-81 analysis to be mild environment equipment post accident (also reference EQWP-J-605A R3) states that a location-specific dose calculation and analysis was performed on the butterfly valves located in Room 1314, and concluded that the subject valves can be recategorized as mild environment equipment. The parameters constitute a mild environment.

12 Determined by XX-53 analysis to be mild environment equipment post accident. EQWP-E-018 R5 states that a specific-location dose calculation and analysis was performed on the MCC's located in Room 1409 and 1410, and concluded that subject MCCs can be recategorized as a mild environment equipment.

16 Qualified as a sub-component of Panel RP209 17 Qualified as a sub-component of Panel RP330 18 Qualified as a sub-component of Panel RP332 19 Spared in Place 20 This equipment was added in response to NUREG-0737 Category II.B.1 21 This equipment was added in response to NUREG-0737 Category II.B.3 22 This equipment was added in response to NUREG-0737 Category II.D.3 24 This equipment was added in response to NUREG-0737 Category II.E.1.2 25 This equipment was added in response to NUREG-0737 Category II.F.1 26 This equipment was added in response to NUREG-0737 Category II.F.2 27 Rooms 1101, 1102, 1120, 1121, 1122 and 1130 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

28 Rooms 1107 and 1108 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

29 Rooms 1113 and 1114 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

30 Rooms 1301, 1314, 1315 and 1320 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

31 Rooms 1508 and 1509 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

32 Rooms 1206 and 1207 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

33 Rooms 1401, 1402 and 1408 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

49 of 50 # Internal Use Only EQSD-II Rev. 35 Table 1: EQ Harsh Environment Equipment List 50 of 50

Component Number MC Equipment Qualification Installed EQ EQ Spec Model # Manufacturer LO HE MS System HOT/ Notes Code Description Elevation Room CA LB LB COLD SHUT 34 Rooms 1502, 1503, 1505 and 1507 plus Rooms 1504, 1506 and 1513 (due to transfer grill GLD0175 on M-1H1431) are all open to one another. A worst-case condition DOWN

of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

35 Rooms 3401, 3406 and 3412 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

36 Rooms 6301 and 6302 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

37 Reference E-035B-00050, Table 3.1, Page 11. The power and control modules are ZSE/ZSI233E, ZSE/ZSI233F, ZSE/ZSI234F, ZNE/ZNI278F and ZNE/ZNI278G.

The instrumentation modules are ZSE/ZSI233D, ZSE/ZSI233G, ZSE/ZSI234E, ZSE/ZSI243C, ZSE/ZSI249C, ZSE/ZSI249D, ZSE/ZSI250A, ZSE/ZSI250B, ZSE/ZSI250D, ZSE/ZSI250F, ZSE/ZSI250G, ZSE/ZSI258F, ZNE/ZNI277F, ZNE/ZNI278C, ZNE/ZNI278D, ZNE/ZNI278E, ZNE/ZNI279E, ZNE/ZNI287C, ZNE/ZNI287D, ZNE/ZNI287E, ZNE/ZNI288B, ZNE/ZNI288D, ZNE/ZNI288F, ZNE/ZNI295F and ZNE/ZNI295G.

38 GDI-30F (Long-glass, fiber filled, diallyl-phthalate) terminal blocks that are Series 601-JJ, 602-JJ, 604-JJ, 605-JJ, 812-JJ type are qualified under PQE-E-035B-P02 for each of these applications. Instrumentation applications do not use the Kulka terminal blocks inside the containment, PQE-E-11013-P01/ P06/P07/ P08/ P09 splices are used in these applications.

39 These assets contain two limit switches. However one of the limit switches is an installed spare and doesnt have power running to it. Therefore, doesnt perform any safety function and doesnt need qualified by the EQ program.

40 Not used 41 DRE 20217 approves changing the identified model 763 to 763A.

42 SWO 18-446734-002 changed model number to 763A.

43 PQE-ESE-43G-P01

44 CP 13788

45 CP 14701 50 Located in yard.

50 of 50 # Internal Use Only EQSD-II Rev. 35 EQSD-II Table 2: 1 of 27 EQ Mild Environment Equipment List Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B 27XQB01 AUX RELAY IN PANEL RP330 1320 E-093 C C C QB BOTH 17 30 27XQB02 AUX RELAY IN PANEL RP330 1320 E-093 C C C QB BOTH 17 30 3XAP02 AUX RELAY IN PANEL RP330 (APV0015) 1320 E-093 C C C AP BOTH 17 30 3XGS23 AUX RELAY IN PANEL RP209 1320 E-093 C C C GS BOTH 16 30 45XJE01 125 VDC AUX RELAY IN PANEL RP330 FOR FIRE SIGNAL ISO 1320 E-093 C C C JE BOTH 17 30 63XFC15 AUX RELAY IN PANEL RP330 1320 E-093 C C C FC BOTH 17 30 63XFC17 AUX RELAY IN PANEL RP330 1320 E-093 C C C FC BOTH 17 30 74XBG03 AUX RELAY PANEL RP209 1320 E-093 C C C BG BOTH 16 30 74XEJ05 AUX RELAY IN PANEL RP332 FOR EJHCV0606 COMPUTER POINT 1320 E-093 C C C EJ BOTH 18 30 95XGK07 AUX RELAY PANEL RP330 1320 E-093 C C C GK BOTH 17 30 AB007 AUX. RELAY RACK 3413 E-093 D D D AB BOTH ABFHC0002 ABPV0002 LOCAL CONTROLLER 1509 J-601B C D C AB BOTH 31 ABFHC0003 ABPV0003 LOCAL CONTROLLER 1509 J-601 C D C AB BOTH 31 ABHY0005 ABHV0005 SOLENOID VALVE 1412 J-601A C D C AB BOTH ABHY0006 ABHV0006 SOLENOID VALVE 1412 J-601A C D C AB BOTH ABHY0048A ABHV0048 SOLENOID VALVE 1412 J-601A C D C AB BOTH ABHY0049A ABHV0049 SOLENOID VALVE 1412 J-601 C D C AB BOTH ABLT0007 MAIN STM LINE DRN VLV LP 3 LV 1331 J-301 D C D AB BOTH ABLT0008 MAIN STM LINE DRN VLV LP 2 LV 1331 J-301 D C D AB BOTH ABLT0009 MAIN STM LINE DRN VLV LP 1 LV 1326 J-301 D D D AB BOTH ABLT0010 MAIN STM LINE DRN VLV LP 4 LV 1325 J-301 D D D AB BOTH ABPI0514A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0515A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0516A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0516X STEAMLINE PRESSURE 1413 ESE-14 D D D AB BOTH ABPI0524A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0524B STEAMLINE PRESSURE 1413 ESE-14 D D D AB BOTH ABPI0525A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0526A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0534A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0535A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0535X STEAMLINE PRESSURE 1413 ESE-14 D D D AB BOTH ABPI0536A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0544A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0544B STEAMLINE PRESSURE 1413 ESE-14 D D D AB BOTH ABPI0545A STEAMLINE PRESSURE 3501 ESE-14 D D D AB BOTH ABPI0546A STEAMLINE PRESSURE 3501 ESE-1 D D D AB BOTH ABPIC0001A STM GEN A ATM STEAM DUMP 3501 J-110 D D D AB BOTH ABPIC0001B STM GEN A ATM STEAM DUMP 1413 J-110 D D D AB BOTH ABPIC0002A STM GEN B ATM STEAM DUMP 3501 J-110 D D D AB BOTH ABPIC0002B STM GEN B ATM STEAM DUMP 1413 J-110 D D D AB BOTH ABPIC0003A STM GEN C ATM STEAM DUMP 3501 J-110 D D D AB BOTH ABPIC0003B STM GEN C ATM STEAM DUMP 1413 J-110 D D D AB BOTH ABPIC0004A STM GEN D ATM STEAM DUMP 3501 J-110 D D D AB BOTH ABPIC0004B STM GEN D ATM STEAM DUMP 1413 J-110 D D D AB BOTH ABPT0001 STM GEN A STEAMLINE PRESSURE 1304 J-301 D D D AB BOTH ABPT0002 STM GEN B STEAMLINE PRESSURE 1305 J-301 D D D AB BOTH ABPT0003 STM GEN C STEAMLINE PRESSURE 1305 J-301 D D D AB BOTH

  1. Internal Use Only 1 of 27 EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 2 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B ABPT0004 STM GEN D STEAMLINE PRESSURE 1304 J-301 D D D AB BOTH ABPV0001 STM GEN A ATM RELIEF VLV 1508 J-601 C D C AB BOTH 31 ABPV0002 STM GEN B ATM RELIEF VLV 1509 J-601 C D C AB BOTH 31 ABPV0003 STM GEN C ATM RELIEF VLV 1509 J-601 C D C AB BOTH 31 ABPV0004 STM GEN D ATM RELIEF VLV 1508 J-601 C D C AB BOTH 31 ABPY0001 ABPV0001 I/P CONVERTER 1508 J-601B C D C AB BOTH 31 ABPY0002 ABPV0002 I/P CONVERTER 1509 J-601B C D C AB BOTH 31 ABPY0003 ABPV0003 I/P CONVERTER 1509 J-601B C D C AB BOTH 31 ABPY0004 ABPV0004 I/P CONVERTER 1508 J-601B C D C AB BOTH 31 ABZC0001 ABPV0001 POSITIONER - STM GEN A ATM VENT VALVE 1508 J-601B C D C AB BOTH ABZC0002 ABPV0002 POSITIONER - STM GEN B ATM VENT VALVE 1509 J-601B C D C AB BOTH ABZC0003 ABPV0003 POSITIONER - STM GEN C ATM VENT VALVE 1509 J-601B C D C AB BOTH ABZC0004 ABPV0004 POSITIONER - STM GEN D ATM VENT VALVE 1508 J-601B C D C AB BOTH ABZE0011AC LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 CLOSED 1508 M-630 C D C AB ---

POSITION DETECTION ELEMENT A ABZE0011AO LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 OPEN POSITION 1508 M-630 C D C AB ---

DETECTION ELEMENT A ABZE0011BC LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 CLOSED 1508 M-630 C D C AB ---

POSITION DETECTION ELEMENT B ABZE0011BO LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 OPEN POSITION 1508 M-630 C D C AB ---

DETECTION ELEMENT B ABZE0014AC LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 CLOSED 1508 M-630 C D C AB ---

POSITION DETECTION ELEMENT A ABZE0014AO LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 OPEN POSITION 1508 M-630 C D C AB ---

DETECTION ELEMENT A ABZE0014BC LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 CLOSED 1508 M-630 C D C AB ---

POSITION DETECTION ELEMENT B ABZE0014BO LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 OPEN POSITION 1508 M-630 C D C AB ---

DETECTION ELEMENT B ABZE0017AC LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 CLOSED 1509 M-630 C D C AB ---

POSITION DETECTION ELEMENT A ABZE0017AO LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 OPEN POSITION 1509 M-630 C D C AB ---

DETECTION ELEMENT A ABZE0017BC LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 CLOSED 1509 M-630 C D C AB ---

POSITION DETECTION ELEMENT B ABZE0017BO LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 OPEN POSITION 1509 M-630 C D C AB ---

DETECTION ELEMENT B ABZE0020AC LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 CLOSED 1509 M-630 C D C AB ---

POSITION DETECTION ELEMENT A ABZE0020AO LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 OPEN POSITION 1509 M-630 C D C AB ---

DETECTION ELEMENT A ABZE0020BC LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 CLOSED 1509 M-630 C D C AB ---

POSITION DETECTION ELEMENT B ABZE0020BO LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 OPEN POSITION 1509 M-630 C D C AB ---

DETECTION ELEMENT B ABZS0005 ABHV0005 LIMIT SWITCH 1412 NAMCO C D C AB BOTH ABZS0006 ABHV0006 LIMIT SWITCH 1412 NAMCO C D C AB BOTH

2 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 3 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B ABZS0048 ABHV0048 LIMIT SWITCH 1412 NAMCO C D C AB BOTH ABZS0049 ABHV0049 LIMIT SWITCH 1412 NAMCO C D C AB BOTH ABZT0011A LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 POSITION 1508 M-630 C D C AB ---

TRANSMITTER A ABZT0011B LOOP 4 MAIN STEAM ISOLATION VALVE ABHV0011 POSITION 1508 M-630 C D C AB ---

TRANSMITTER B ABZT0014A LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 POSITION 1508 M-630 C D C AB ---

TRANSMITTER A ABZT0014B LOOP 1 MAIN STEAM ISOLATION VALVE ABHV0014 POSITION 1508 M-630 C D C AB ---

TRANSMITTER B ABZT0017A LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 POSITION 1509 M-630 C D C AB ---

TRANSMITTER A ABZT0017B LOOP 2 MAIN STEAM ISOLATION VALVE ABHV0017 POSITION 1509 M-630 C D C AB ---

TRANSMITTER B ABZT0020A LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 POSITION 1509 M-630 C D C AB ---

TRANSMITTER A ABZT0020B LOOP 3 MAIN STEAM ISOLATION VALVE ABHV0020 POSITION 1509 M-630 C D C AB ---

TRANSMITTER B ACPSL0231 MN STM CTRL VLV 2 PRESS SW 4401 J-110 D D D AC ---

ACPSL0232 MN STM CTRL VLV 3 PRESS SW 4401 J-110 D D D AC ---

ACPSL0233 MN STM CTRL VLV 1 PRESS SW 4401 J-110 D D D AC ---

ACPT0231 MN STM CTRL VLV 3 4401 J-301 D D D AC ---

ACPT0232 MN STM CTRL VLV 2 4401 J-301 D D D AC ---

ACPT0233 MN STM CTRL VLV 1 4401 J-301 D D D AC ---

ACPT0505 TURBINE IMPULSE PRESSURE 4401 M-771 D D D AC ---

ACPT0506 TURBINE IMPULSE PRESSURE 4401 M-771 D D D AC ---

ACZS0043C TURB TRP STOP VLV LMT SWITCH 4401 J-601A D D D AC ---

ACZS0044C TURB TRP STOP VLV LMT SWITCH 4401 J-601A D D D AC ---

ACZS0045C TURB TRP STOP VLV LMT SWITCH 4401 J-601A D D D AC ---

ACZS0046C TURB TRP STOP VLV LMT SWITCH 4401 J-601 D D D AC ---

AEFY0043 AEFV0043 SOLENOID VALVE 1411 J-601A C D C AE BOTH AEFY0044 AEFV0044 SOLENOID VALVE 1412 J-601A C D C AE BOTH AEFY0045 AEFV0045 SOLENOID VALVE 1412 J-601A C D C AE BOTH AEFY0046 AEFV0046 SOLENOID VALVE 1411 J-60 C D C AE BOTH AEFY0510AA FEEDWATER CONTROL VALVE LOOP 1 4401 HE-5 D D D AE ---

AEFY0510BB FEEDWATER CONTROL VALVE LOOP 1 4401 HE-5 D D D AE ---

AEFY0520AA FEEDWATER CONTROL VALVE LOOP 2 4401 HE-5 D D D AE ---

AEFY0520BB FEEDWATER CONTROL VALVE LOOP 2 4401 HE-5 D D D AE ---

AEFY0530AA FEEDWATER CONTROL VALVE LOOP 3 4401 HE-5 D D D AE ---

AEFY0530BB FEEDWATER CONTROL VALVE LOOP 3 4401 HE-5 D D D AE ---

AEFY0540AA FEEDWATER CONTROL VALVE LOOP 4 4401 HE-5 D D D AE ---

AEFY0540BB FEEDWATER CONTROL VALVE LOOP 4 4401 HE-5 D D D AE ---

AEFY0550A FEEDWATER CONTROL BYPASS VALVE LOOP 1 4401 HE-5 D D D AE ---

AEFY0550B FEEDWATER CONTROL BYPASS VALVE LOOP 1 4401 HE-5 D D D AE ---

AEFY0560A FEEDWATER CONTROL BYPASS VALVE LOOP 2 4401 HE-5 D D D AE ---

AEFY0560B FEEDWATER CONTROL BYPASS VALVE LOOP 2 4401 HE-5 D D D AE ---

AEFY0570A FEEDWATER CONTROL BYPASS VALVE LOOP 3 4401 HE-5 D D D AE ---

AEFY0570B FEEDWATER CONTROL BYPASS VALVE LOOP 3 4401 HE-5 D D D AE ---

3 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 4 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B AEFY0580A FEEDWATER CONTROL BYPASS VALVE LOOP 4 4401 HE-5 D D D AE ---

AEFY0580B FEEDWATER CONTROL BYPASS VALVE LOOP 4 4401 HE-5 > D D D AE ---

AELI0501 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0501A STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0502 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0502A STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0503 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0503A STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0504 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0504A STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0517 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0517X STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0518 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0519 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0527 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0527X STEAM GENERATOR WATER LEVEL (INSTALLED SPARE) 1413 ESE-14 D D D AE ---

AELI0528 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0528X STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0529 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0537 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0537X STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0538 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0539 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0547 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0548 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AELI0548X STEAM GENERATOR WATER LEVEL 1413 ESE-14 D D D AE BOTH AELI0549 STEAM GENERATOR WATER LEVEL 3501 ESE-14 D D D AE BOTH AEZE0039AC LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 CLOSED 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0039AO LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 OPEN 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0039BC LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 CLOSED 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0039BO LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 OPEN 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0040AC LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 CLOSED 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0040AO LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 OPEN 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0040BC LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 CLOSED 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0040BO LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 OPEN 1411 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0041AC LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV0041 CLOSED 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0041AO LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV00341 OPEN 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT A

4 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 5 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B AEZE0041BC LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV0041 CLOSED 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0041BO LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV0041 OPEN 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0042AC LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 CLOSED 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0042AO LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 OPEN 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT A AEZE0042BC LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 CLOSED 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZE0042BO LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 OPEN 1412 M-628 C D C AE ---

POSITION DETECTION ELEMENT B AEZS0043 AEFV0043 LIMIT SWITCH 1411 NAMCO C D C AE BOTH AEZS0044 AEFV0044 LIMIT SWITCH 1412 NAMCO C D C AE BOTH AEZS0045 AEFV0045 LIMIT SWITCH 1412 NAMCO C D C AE BOTH AEZS0046 AEFV0046 LIMIT SWITCH 1411 NAMCO C D C AE BOTH AEZT0039A LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 POSITION 1411 M-628 C D C AE ---

TRANSMITTER A AEZT0039B LOOP 1 MAIN FEEDWATER ISOLATION VALVE AEFV0039 POSITION 1411 M-628 C D C AE ---

TRANSMITTER B AEZT0040A LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 POSITION 1411 M-628 C D C AE ---

TRANSMITTER A AEZT0040B LOOP 2 MAIN FEEDWATER ISOLATION VALVE AEFV0040 POSITION 1411 M-628 C D C AE ---

TRANSMITTER B AEZT0041A LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV0041 POSITION 1412 M-628 C D C AE ---

TRANSMITTER A AEZT0041B LOOP 3 MAIN FEEDWATER ISOLATION VALVE AEFV0041 POSITION 1412 M-628 C D C AE ---

TRANSMITTER B AEZT0042A LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 POSITION 1412 M-628 C D C AE ---

TRANSMITTER A AEZT0042B LOOP 4 MAIN FEEDWATER ISOLATION VALVE AEFV0042 POSITION 1412 M-628 C D C AE ---

TRANSMITTER B ALFI0001A AUX FDWTR PMP TO STEAM GEN D 3501 J-110 D D D AL HOT 24 ALFI0001B AUX FDWTR PMP TO STEAM GEN D 1413 J-110 D D D AL HOT 24 ALFI0002A AUX FDWTR PMP TO STEAM GEN A 3501 J-110 D D D AL HOT 24 ALFI0002B AUX FDWTR PMP TO STEAM GEN A 1413 J-110 D D D AL HOT 24 ALFI0003A AUX FDWTR PMP TO STEAM GEN B 3501 J-110 D D D AL HOT 24 ALFI0003B AUX FDWTR PMP TO STEAM GEN B 1413 J-110 D D D AL HOT 24 ALFI0004A AUX FDWTR PMP TO STEAM GEN C 3501 J-110 D D D AL HOT 24 ALFI0004B AUX FDWTR PMP TO STEAM GEN C 1413 J-110 D D D AL HOT 24 ALFT0001 AUX FDWTR PMP TO STEAM GEN D 1304 J-301 C D D AL HOT 24 ALFT0002 AUX FDWTR PMP TO STEAM GEN A 1304 J-301 C D D AL HOT 24 ALFT0003 AUX FDWTR PMP TO STEAM GEN B 1305 J-301 D D D AL HOT 24 ALFT0004 AUX FDWTR PMP TO STEAM GEN C 1305 J-301 D D D AL HOT 24 ALFT0007 AUX FDW FLO TO SG A 1304 J-301 C D D AL HOT 24 ALFT0009 AUX FDW FLO TO SG B 1305 J-301 D D D AL HOT 24

5 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 6 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B ALFT0011 AUX FDW FLO TO SG C 1305 J-301 D D D AL HOT 24 ALHK0005A MOT AUX FW PMP B DISCH TO STM GEN D 3501 J-110 D D D AL HOT ALHK0005B MOT AUX FW PMP B DISCH TO STM GEN D 1413 J-110 D D D AL HOT ALHK0006A TURB AFP DISCH TO STEAM GEN D 3501 J-110 D D D AL HOT ALHK0006B TURB AFP DISCH TO STEAM GEN D 1413 J-110 D D D AL HOT ALHK0007A MOT AUX FW PMP B DISCH TO STM GEN A 3501 J-110 D D D AL HOT ALHK0007B MOT AUX FW PMP B DISCH TO STM GEN A 1413 J-110 D D D AL HOT ALHK0008A TURB AFP DISCH TO STEAM GEN A 3501 J-110 D D D AL HOT ALHK0008B TURB AFP DISCH TO STEAM GEN A 1413 J-110 D D D AL HOT ALHK0009A MOT AUX FW PMP A DISCH TO STM GEN B 3501 J-110 D D D AL HOT ALHK0009B MOT AUX FW PMP A DISCH TO STM GEN B 1413 J-110 D D D AL HOT ALHK0010A TURB AFP DISCH TO STEAM GEN B 3501 J-110 D D D AL HOT ALHK0010B TURB AFP DISCH TO STEAM GEN B 1413 J-110 D D D AL HOT ALHK0011A MOT AUX FW PMP A DISCH TO STM GEN C 3501 J-110 D D D AL HOT ALHK0011B MOT AUX FW PMP A DISCH TO STM GEN C 1413 J-110 D D D AL HOT ALHK0012A TURB AFP DISCH TO STEAM GEN C 3501 J-110 D D D AL HOT ALHK0012B TURB AFP DISCH TO STEAM GEN C 1413 J-110 D D D AL HOT ALHV0005 MOT AUX FDWTR PMP B DISCH ISO 1324 J-601 D D D AL HOT ALHV0006-E01 VALVE TERMINAL BOX 1327 E-028 D D D AL HOT ALHV0007 MOT AUX FDWTR PMP B DISCH ISO 1324 J-601 D D D AL HOT ALHV0008-E01 VALVE TERMINAL BOX 1327 E-028 D D D AL HOT ALHV0009 MOT AUX FDWTR PMP A DISCH ISO 1328 J-601 D D D AL HOT ALHV0010-E01 VALVE TERMINAL BOX 1330 E-028 D D D AL HOT ALHV0011 MOT AUX FDWTR PMP A DISCH ISO 1328 J-601 D D D AL HOT ALHV0012-E01 VALVE TERMINAL BOX 1330 E-028 D D D AL HOT ALHV0030 ESW TO AUX. FEED PUMP B 1206 M-236A C D D AL HOT 32 ALHV0031 ESW TO AUX. FEED PUMP A 1206 M-236A C D D AL HOT 32 ALHV0032 TURBINE AF PUMP SUCTION FROM ESW A 1207 M-236A C D D AL HOT 32 ALHV0033 TURBINE AF PUMP SUCTION FROM ESW B 1207 M-236A C D D AL HOT 32 ALHV0034 CST TO AUXILIARY FEED PUMP B 1206 LIMITORQUE C D D AL HOT 32 ALHV0035 CST TO AUXILIARY FEED PUMP A 1206 LIMITORQUE C D D AL HOT 32 ALHV0036 TURBINE AF PUMP SUCTION FROM CST 1207 LIMITORQUE C D D AL HOT 32 ALHY0006 ALHV0006 I/P CONVERTER 1327 J-601A D D D AL HOT ALHY0008 ALHV0008 I/P CONVERTER 1327 J-601A D D D AL HOT ALHY0010 ALHV0010 I/P CONVERTER 1330 J-601A D D D AL HOT ALHY0012 ALHV0012 I/P CONVERTER 1330 J-601 D D D AL HOT ALPI0024A MOT AUX FDWTR PMP B SUCT PRESS 3501 J-110 D D D AL HOT ALPI0024B MOT AUX FDWTR PMP B SUCT PRESS 1413 J-110 D D D AL HOT ALPI0025A MOT AUX FDW PMP A SUCT PRESS 3501 J-110 D D D AL HOT ALPI0025B MOT AUX FDW PMP A SUCT PRESS 1413 J-110 D D D AL HOT ALPI0026A TURB AUX FDWTR PMP SUCT PRESS 3501 J-110 D D D AL HOT ALPI0026B TURB AUX FDWTR PMP SUCT PRESS 1413 J-110 D D D AL HOT ALPI0037 AFW SPLY PRESS FROM COND STR TK 3501 J-110 D D D AL HOT ALPI0038 AFW SPLY PRESS FROM COND STR TK 3501 J-110 D D D AL HOT ALPI0039 AFW SPLY PRESS FROM COND STR TK 3501 J-110 D D D AL HOT ALPT0024 MOT AUX FEEDWATER PMP B SUCT PRESS 1325 J-301 D D D AL HOT ALPT0025 CST TO MOT AUX FDW PMP A SUCT PRESS 1326 J-301 D D D AL HOT ALPT0026 TURB AUX FEEDWATER PMP SUCT PRESS 1331 J-301 D C D AL HOT

6 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 7 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B ALPT0037 ESFAS LOW SUCTION PRESS 1207 J-301 C D D AL HOT 32 ALPT0038 ESFAS LOW SUCTION PRESS 1207 J-301 C D D AL HOT 32 ALPT0039 ESFAS LOW SUCTION PRESS 1207 J-301 C D D AL HOT 32 ALZS0006 ALHV0006 LIMIT SWITCH 1327 J-601A D D D AL HOT ALZS0008 ALHV0008 LIMIT SWITCH 1327 J-601A D D D AL HOT ALZS0010 ALHV0010 LIMIT SWITCH 1330 J-601A D D D AL HOT ALZS0012 ALHV0012 LIMIT SWITCH 1330 J-601A D D D AL HOT BB007 D.C. CONTACTOR FOR PORV 1403 E-018A D D D BB BOTH BB008 D.C. CONTACTOR FOR PORV 1408 E-018 D D D BB BOTH 33 BBFT0414 RCS FLOW TRANSMITTER LOOP 1 2201 ESE-4 C D C BB BOTH BBFT0415 RCS FLOW TRANSMITTER LOOP 1 2201 ESE-4 C D C BB BOTH BBFT0416 RCS FLOW TRANSMITTER LOOP 1 2201 ESE-4 C D C BB BOTH BBFT0424 RCS FLOW TRANSMITTER LOOP 2 2201 ESE-4 C D C BB BOTH BBFT0425 RCS FLOW TRANSMITTER LOOP 2 2201 ESE-4 C D C BB BOTH BBFT0426 RCS FLOW TRANSMITTER LOOP 2 2201 ESE-4 C D C BB BOTH BBFT0434 RCS FLOW TRANSMITTER LOOP 3 2201 ESE-4 C D C BB BOTH BBFT0435 RCS FLOW TRANSMITTER LOOP 3 2201 ESE-4 C D C BB BOTH BBFT0436 RCS FLOW TRANSMITTER LOOP 3 2201 ESE-4 C D C BB BOTH BBFT0444 RCS FLOW TRANSMITTER LOOP 4 2201 ESE-4 C D C BB BOTH BBFT0445 RCS FLOW TRANSMITTER LOOP 4 2201 ESE-4 C D C BB BOTH BBFT0446 RCS FLOW TRANSMITTER LOOP 4 2201 ESE-4 C D C BB BOTH BBHV8037A PRT EMERGENCY DRAIN LINE 2000 LIMITORQUE C D C BB BOTH BBHV8037B PRT EMERGENCY DRAIN LINE 2000 LIMITORQUE C D C BB BOTH BBHV8157A EXCESS LETDOWN PATH TO PRT ISOLATION 2000 M-231E C D C BB BOTH BBHV8157B EXCESS LETDOWN PATH TO PRT ISOLATION 2000 M-231E C D C BB BOTH BBLI0459A PRESSURIZER LEVEL 3501 ESE-14 D D D BB BOTH BBLI0459B PRESSURIZER LEVEL 1413 ESE-14 D D D BB BOTH BBLI0460A PRESSURIZER LEVEL 3501 ESE-14 D D D BB BOTH BBLI0460B PRESSURIZER LEVEL 1413 ESE-14 D D D BB BOTH BBLI0461 PRESSURIZER LEVEL 3501 ESE-14 D D D BB BOTH BBLI1311 REACTOR VESSEL LEVEL INDICATORS 3501 ESE-14 D D D BB --- 26 BBLI1312 REACTOR VESSEL LEVEL INDICATORS 3501 ESE-14 D D D BB --- 26 BBLI1321 REACTOR VESSEL LEVEL INDICATORS 3501 ESE-14 D D D BB --- 26 BBLI1322 REACTOR VESSEL LEVEL INDICATORS 3501 ESE-14 D D D BB --- 26 BBLT1311 REACTOR VESSEL LEVEL TRANSMITTER NARROW RANGE 1320 ESE-4A D C D BB --- 26 BBLT1312 REACTOR VESSEL LEVEL TRANSMITTER WIDE RANGE 1320 ESE-4A D C D BB --- 26 BBLT1321 REACTOR VESSEL LEVEL TRANSMITTER NARROW RANGE 1202 ESE-4A D C D BB --- 26 BBLT1322 REACTOR VESSEL LEVEL TRANSMITTER WIDE RANGE 1202 ESE-4A D C D BB --- 26 BBPI0403 REACTOR COOLANT PRESSURE INDICATOR 3501 ESE-14 D D D BB BOTH BBPI0403X REACTOR COOLANT PRESSURE INDICATOR (ASP-SPARE) 1413 ESE-14 D D D BB ---

BBPI0405 REACTOR COOLANT PRESSURE INDICATOR 3501 ESE-14 D D D BB BOTH BBPI0405X REACTOR COOLANT PRESSURE INDICATOR 1413 ESE-14 D D D BB BOTH BBPI0406 REACTOR COOLANT PRESSURE INDICATOR 3501 ESE-14 D D D BB BOTH BBPI0406X REACTOR COOLANT PRESSURE INDICATOR 1413 ESE-14 D D D BB BOTH BBT/C0011-E01 THERMOCOUPLE CONNECTOR/CABLE ASSEMBLIES Spare 2000 J-565 C C C BB --- 26 BBT/C0016-E01 THERMOCOUPLE CONNECTOR/CABLE ASSEMBLIES Spare 2000 J-565 C C C BB --- 26 BBT/C0035-E01 THERMOCOUPLE CONNECTOR/CABLE ASSEMBLIES Spare 2000 J-565 C C C BB --- 26

7 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 8 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B BBTI0413A TH WIDE RANGE LOOP 1 HOT LEG TEMP 3501 ESE-14 D D D BB BOTH BBTI0413B TH WIDE RANGE LOOP 1 COLD LEG TEMP 3501 ESE-14 D D D BB BOTH BBTI0423A TH WIDE RANGE LOOP 2 HOT LEG TEMP 3501 ESE-14 D D D BB BOTH BBTI0423B TH WIDE RANGE LOOP 2 COLD LEG TEMP 3501 ESE-14 D D D BB BOTH BBTI0423X TH WIDE RANGE LOOP 2 COLD LEG TEMP 1413 ESE-14 D D D BB BOTH BBTI0443A TH WIDE RANGE LOOP 4 HOT LEG TEMP 1413 ESE-14 D D D BB BOTH BBTI1390A SUBCOOLING TEMP IND 3501 ESE-14 D D D BB --- 26 BBTI1390B SUBCOOLING TEMP IND 3501 ESE-14 D D D BB --- 26 BBTR1390A SUBCOOLING RECORDER 3605 ESE-46B D D D BB ---

BBTR1390B SUBCOOLING RECORDER 3605 ESE-46B D D D BB ---

BBUU1390A SUBCOOLING REMOTE DISPLAY 3605 ESE-46A D D D BB ---

BBUU1390B SUBCOOLING REMOTE DISPLAY 3605 ESE-46A D D D BB ---

BGFI0138A EXCESS LETDOWN FLOW TO PRT 3501 ESE-14 D D D BG BOTH BGFI0138B EXCESS LETDOWN FLOW TO PRT 3501 ESE-14 D D D BG BOTH BGFI0215A SEAL INJECTION FLOW 3501 ESE-14 D D D BG BOTH BGFI0215B SEAL INJECTION FLOW 3501 ESE-14 D D D BG BOTH BGFT0138A EXCESS LETDOWN PATH TO PRT FLOW TRANSMITTER 2000 ESE-3 C D C BG BOTH BGFT0138B EXCESS LETDOWN PATH TO PRT FLOW TRANSMITTER 2000 ESE-3 C D C BG BOTH BGFT0215B RCP SEAL INJECTION FLOW TRANSMITTER 1202 ESE-4A A C D BG BOTH BGHV8104 EMERGENCY BORATION PATH ISOLATION VALVE 1113 LIMITORQUE C D D BG BOTH 29 BGHV8357A CCP A ALTERNATE DISCHARGE TO RCP SEALS 1114 M-231E C D D BG BOTH 29 BGHV8357B CCP B ALTERNATE DISCHARGE TO RCP SEALS 1107 M-231E C D D BG BOTH 28 BGLI0102 BORIC ACID TANK #1 LEVEL 3501 ESE-14 D D D BG BOTH BGLI0104 BORIC ACID TANK 1 LEVEL 3501 ESE-14 D D D BG BOTH BGLI0105 BORIC ACID TANK #2 LEVEL 3501 ESE-14 D D D BG BOTH BGLI0106 BORIC ACID TANK 2 LEVEL 3501 ESE-14 D D D BG BOTH BGLI0112 VOLUME CONTROL TANK LEVEL 3501 ESE-14 D D D BG BOTH BGLI0185 VOLUME CONTROL TANK LEVEL 3501 ESE-14 D D D BG BOTH BGLT0102 BORIC ACID TANK A LEVEL TRANSMITTER 1117 ESE-4 C D D BG BOTH BGLT0104 BORIC ACID TANK A LEVEL TRANSMITTER 1117 ESE-4 C D D BG BOTH BGLT0105 BORIC ACID TANK B LEVEL TRANSMITTER 1116 ESE-4 C D D BG BOTH BGLT0106 BORIC ACID TANK B LEVEL TRANSMITTER 1116 ESE-4 C D D BG BOTH BGLT0112 VCT LEVEL TRANSMITTER 1318 ESE-4 C C D BG BOTH BGLT0185 VCT LEVEL TRANSMITTER 1316 ESE-4A C C D BG BOTH BGTE0032 DPBG05A INBOARD BEARING TEMPERATURE 1114 M-721 C D D BG --- 29 BGTE0033 DPBG05A OUTBOARD BEARING TEMPERATURE 1114 M-721 C D D BG --- 29 BGTE0034 DPBG05B INBOARD BEARING TEMPERATURE 1107 M-721 C D D BG --- 28 BGTE0035 DPBG05B OUTBOARD BEARING TEMPERATURE 1107 M-721 C D D BG --- 28 BGTE0137A EXCESS LETDOWN PATH TO PRT TEMPERATURE ELEMENT 2000 ESE-42A C D C BG BOTH BGTE0137B EXCESS LETDOWN PATH TO PRT TEMPERATURE ELEMENT 2000 ESE-42A C D C BG BOTH BGTI0137A EXCESS LETDOWN TO PRT TEMP 3501 ESE-14 D D D BG BOTH BGTI0137B EXCESS LETDOWN FLOW TO PRT TEMP 3501 ESE-14 D D D BG BOTH BNHS8812B ISOLATION SWITCH FOR BNHV8812B 3302 E-028B D D D BN COLD BNLI0930 RWST LEVEL 3501 ESE-14 D D D BN ---

BNLI0931 RWST LEVEL 3501 ESE-14 D D D BN ---

BNLI0932 RWST LEVEL 3501 ESE-14 D D D BN ---

BNLI0933 RWST LEVEL 3501 ESE-14 D D D BN ---

BNLT0930 RWST LEVEL TRANSMITTER 9102 ESE-4 D D D BN ---

8 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 9 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B BNLT0931 RWST LEVEL TRANSMITTER 9102 ESE-4 D D D BN ---

BNLT0932 RWST LEVEL TRANSMITTER 9102 ESE-4 D D D BN ---

BNLT0933 RWST LEVEL TRANSMITTER 9102 ESE-4 D D D BN ---

BNTE0002 RWST TEMP 9102 J-558B D D D BN ---

BNTE0005 RWST TEMP 9102 J-558B D D D BN ---

BNTI0002 RWST TEMP 3501 J-110 D D D BN ---

BNTI0005 RWST TEMP 3501 J-110 D D D BN ---

BNTT0002 RWST TEMP 3605 J-110 D D D BN ---

BNTT0005 RWST TEMP 3605 J-110 D D D BN ---

BNZS0011 RWST OUTLET HEADER VALVE POSITION 9102 M-221 D D D BN ---

BNZS8717 POSITION SWITCH ON RHR RETURN VALVE 1310 HE-6 C D D BN ---

DCGD01A ESW PUMP ROOM SUPPLY FAN MOTOR K105 M-619.2 D D D GD BOTH DCGD01B ESW PUMP ROOM SUPPLY FAN MOTOR K104 M-619.2 D D D GD BOTH DCGG02A EMERGENCY EXH. FAN MOTOR 6304 M-619.2 D D D GG ---

DCGG02B EMERGENCY EXH. FAN MOTOR 6303 M-619.2 D D D GG ---

DCGK03A CONTROL ROOM FILTER FAN MOTOR 1512 M-619.2 D D D GK ---

DCGK03B CONTROL ROOM FILTER FAN MOTOR 1501 M-619.2 D D D GK ---

DCGK04A CONTROL ROOM PRESSURE FAN MOTOR 3416 M-619.2 D D D GK ---

DCGK04B CONTROL ROOM PRESSURE FAN MOTOR 3415 M-619.2 D D D GK ---

DCGM01A DIESEL GEN. VENT. SUPPLY FAN MOTOR 5203 M-619.2 D D D GM BOTH DCGM01B DIESEL GEN. VENT. SUPPLY FAN MOTOR 5201 M-619.2 D D D GM BOTH DCGN03A HYDROGEN MIXING FAN MOTOR 2000 M-619.3 C D C GN HOT DCGN03B HYDROGEN MIXING FAN MOTOR 2000 M-619.3 C D C GN HOT DCGN03C HYDROGEN MIXING FAN MOTOR 2000 M-619.3 C D C GN HOT DCGN03D HYDROGEN MIXING FAN MOTOR 2000 M-619.3 C D C GN HOT DPAL01A AUX FEEDWATER PUMP A MOTOR 1326 E-012.2 D D D AL HOT DPAL01B AUX FEEDWATER PUMP B MOTOR 1325 E-012.2 D D D AL HOT DPBG02A BORIC ACID TRANSFER PUMP A MOTOR 1117 AE-3 C D D BG BOTH DPBG02B BORIC ACID TRANSFER PUMP B MOTOR 1116 AE-3 C D D BG BOTH DPEC01A SPENT FUEL POOL COOLING PUMP A MOTOR 6105 M-084 D D D EC --- 3 DPEC01B SPENT FUEL POOL COOLING PUMP B MOTOR 6104 M-084 D D D EC --- 3 DPEF01A ESW PUMP A MOTOR K105 E-012.2 D D D EF BOTH DPEF01B ESW PUMP B MOTOR K104 E-012.2 D D D EF BOTH DPEG01A CCW PUMP A MOTOR TRAIN A 1406 E-012.2 D D D EG BOTH DPEG01B CCW PUMP B MOTOR TRAIN B 1401 E-012.2 D D D EG BOTH 33 DPEG01C CCW PUMP C MOTOR TRAIN A 1406 E-012.2 D D D EG BOTH DPEG01D CCW PUMP D MOTOR TRAIN B 1401 E-012.2 D D D EG BOTH 33 DPJE01A EMERGENCY FUEL OIL TRANSFER PUMP A MOTOR (50) M-087 D D D JE BOTH DPJE01B EMERGENCY FUEL OIL TRANSFER PUMP B MOTOR (50) M-087 D D D JE BOTH DPKJ01A JACKET WATER KEEP WARM PUMP A MOTOR 5203 M-018 D D D KJ BOTH DPKJ01B JACKET WATER KEEP WARM PUMP B MOTOR 5201 M-018 D D D KJ BOTH DPKJ02A ROCKER PRELUBE PUMP A MOTOR 5203 M-018 D D D KJ BOTH DPKJ02B ROCKER PRELUBE PUMP B MOTOR 5201 M-018 D D D KJ BOTH DPKJ03A AUXILIARY LUBE OIL KEEP WARM PUMP A MOTOR 5203 M-018 D D D KJ BOTH DPKJ03B AUXILIARY LUBE OIL KEEP WARM PUMP B MOTOR 5201 M-018 D D D KJ BOTH DSGF02A AUX FEED PUMP ROOM COOLER MOTOR 1326 M-612 D D D GF BOTH DSGF02B AUX FEED PUMP ROOM COOLER MOTOR 1325 M-612 D D D GF BOTH

9 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 10 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B DSGG04A SFP PUMP ROOM COOLER MOTOR 6105 M-612 D D D GG --- 3 DSGG04B SFP PUMP ROOM COOLER MOTOR 6104 M-612 D D D GG --- 3 DSGL11A CCW PUMP ROOM COOLER MOTOR 1406 M-612 D D D GL BOTH DSGL11B CCW PUMP ROOM COOLER MOTOR 1401 M-612 D D D GL BOTH 33 ECHV0011 F.P.C.H. EX. CCW ISOLATION VALVE LOOP A 6105 M-236 D D D EC BOTH ECHV0012 F.P.C.H. EX. CCW ISOLATION VALVE LOOP B 6104 M-236 D D D EC BOTH ECLSL0057 FUEL POOL LEVEL SWITCH 6106 J-481 D D D EC BOTH ECLSL0058 FUEL POOL LEVEL SWITCH 6106 J-481 D D D EC BOTH EF155 ESW CONTROL PNL K104 J-201 D D D EF BOTH EF156 ESW CONTROL PNL K105 J-201 D D D EF BOTH EFFI0053 ESW A FLO TO POWER BLOCK 3501 J-110 D D D EF ---

EFFI0054 ESW B FLO TO POWER BLOCK 3501 J-110 D D D EF ---

EFFT0039 WARMING LINE FLOW TRANSMITTER K105 J-301 D D D EF ---

EFFT0042 WARMING LINE FLOW TRANSMITTER K104 J-301 D D D EF ---

EFFT0053 ESW A FLO TO POWER BLOCK 3101 J-301 D D D EF ---

EFFT0054 ESW B FLO TO POWER BLOCK 3101 J-301 D D D EF ---

EFHS0003 LOCAL CONTROL STATION K105 E-028 D D D EF ---

EFHS0004 LOCAL CONTROL STATION K104 E-028 D D D EF ---

EFHS0026A ISOLATION SWITCH FOR EFHV0026 3302 E-028B D D D EF BOTH EFHS0038A ISOLATION SWITCH FOR EFHV0038 3302 E-028B D D D EF BOTH EFHV0023 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0024 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0025 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0026 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0037 ULTIMATE HEAT SINK ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0038 ULTIMATE HEAT SINK ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0039 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0040 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0041 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0042 SERVICE WATER ISOLATION VALVE 3101 M-235 D D D EF BOTH EFHV0051 CCW ISOLATION VALVE 1406 M-236 D D D EF BOTH EFHV0052 CCW ISOLATION VALVE 1401 M-236 D D D EF BOTH 33 EFHV0059 CCW ISOLATION VALVE 1406 M-236 D D D EF BOTH EFHV0060 CCW ISOLATION VALVE 1401 M-236 D D D EF BOTH 33 EFHV0091 TRAVELING WATER SCREEN A SPRAY VALVE K105 LIMITORQUE D D D EF BOTH EFHV0092 TRAVELING WATER SCREEN B SPRAY VALVE K104 LIMITORQUE D D D EF BOTH EFHV0097 ESW PUMP A VENT VALVE K105 LIMITORQUE D D D EF BOTH EFHV0098 ESW PUMP B VENT VALVE K104 LIMITORQUE D D D EF BOTH EFPDI0019 ESW 2A SELF-CLN STR DIFF PRES K105 J-110 D D D EF BOTH EFPDI0020 ESW 2B SELF-CLN STR DIFF PRES K104 J-110 D D D EF BOTH EFPDS0019A ESW 2A SELF-CLN STR. DP SWITCH K105 J-301 D D D EF BOTH EFPDS0020A ESW 2B SELF-CLN STR. DP SWITCH K104 J-301 D D D EF BOTH EFPDT0019 ESW 2A SELF-CLN STR DIFF PRES K105 J-301 D D D EF BOTH EFPDT0020 ESW 2B SELF-CLN STR DIFF PRES K104 J-301 D D D EF BOTH EFPDV0019 STRAINER A TRASH VALVE K105 LIMITORQUE D D D EF BOTH EFPDV0020 STRAINER B TRASH VALVE K104 LIMITORQUE D D D EF BOTH EFPI0001 ESW PUMP 1A DISCH PRESS 3501 J-110 D D D EF BOTH

10 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 11 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B EFPI0002 ESW PMP 1B DISCH PRESS 3501 J-110 D D D EF BOTH EFPT0001 ESW PMP 1A DISCH PRESS K105 J-301 D D D EF BOTH EFPT0002 ESW PMP 1B DISCH PRESS K104 J-301 D D D EF BOTH EFTE0061 ESW A TEMP TO POWER BLOCK 3101 J-558B D D D EF ---

EFTE0062 ESW B TEMP TO POWER BLOCK 3101 J-558B D D D EF ---

EFTI0061 ESW A TEMP TO POWER BLOCK 3501 J-110 D D D EF ---

EFTI0062 ESW B TEMP TO POWER BLOCK 3501 J-110 D D D EF ---

EGFI0128 CCW HX OUT TO RCP BY-PASS 3501 J-110 D D D EG BOTH EGFI0129 CCW HX OUT TO RCP BY-PASS 3501 J-110 D D D EG BOTH EGFT0107 CCW HX`S FLOW OUT TO RWB NONESSENTIAL COMP 1314 J-301 C C D EG BOTH 30 EGFT0108 CCW HX`S FLOW OUT TO RWB NONESSENTIAL COMP 1314 J-301 C C D EG BOTH 30 EGHS0070A LOCAL CONTROL STATION 1408 E-028B D D D EG COLD 33 EGHV0011 EMERGENCY MAKEUP WATER TRAIN A FROM ESW 1406 M-231B D D D EG BOTH EGHV0012 EMERGENCY MAKEUP WATER TRAIN B FROM ESW 1401 M-231B D D D EG BOTH 33 EGHV0013 EMERGENCY MAKEUP WATER TRAIN A FROM ESW 1406 M-231B D D D EG BOTH EGHV0014 EMERGENCY MAKEUP WATER TRAIN B FROM ESW 1401 M-231 D D D EG BOTH 33 EGHV0015 CCW COMMON HEADER RETURN ISO TRAIN A 1402 M-261 D D D EG COLD 33 EGHV0016 CCW COMMON HEADER RETURN ISO TRAIN B 1402 M-261 D D D EG COLD 33 EGHV0053 TRAIN A CCW TO COMMON HEADER 1402 M-261 D D D EG COLD 33 EGHV0054 TRAIN B CCW TO COMMON HEADER 1401 M-261 D D D EG COLD 33 EGHV0069A CCW SUPPLY WASTE HEADER ISO 1314 CORR. J-605A D C D EG COLD 11 EGHV0069A-E01 VALVE TERMINAL BOX 1314 CORR. E-028 D C D EG COLD EGHV0069B CCW RETURN WASTE HEADER ISO 1314 CORR. J-605A D C D EG COLD 11 EGHV0069B-E01 VALVE TERMINAL BOX 1314 CORR. E-028 D C D EG COLD EGHV0070A CCW SUPPLY WASTE HEADER ISO 1314 CORR. J-605A D C D EG COLD 11 EGHV0070A-E01 VALVE TERMINAL BOX 1314 CORR. E-028 D C D EG COLD EGHV0070B CCW RETURN WASTE HEADER ISO 1314 CORR. J-605A D C D EG COLD 11 EGHV0070B-E01 VALVE TERMINAL BOX 1314 E-028 D C D EG COLD 30 EGHV0101 RHR A INLET CCW ISOLATION VALVE 1408 M-236 D D D EG COLD 33 EGHV0102 RHR B INLET CCW ISOLATION VALVE 1402 M-236 D D D EG COLD 33 EGHV0126 EGHV0071 BYPASS VALVE 1323 LIMITORQUE C D D EG BOTH EGHV0127 EGHV0058 BYPASS VALVE 1323 LIMITORQUE C D D EG BOTH EGHV0130 EGHV0060 BYPASS VALVE 2000 LIMITORQUE C D C EG BOTH EGHV0131 EGHV0059 BYPASS VALVE 1323 LIMITORQUE C D D EG BOTH EGHV0132 EGHV0062 BYPASS VALVE 2000 LIMITORQUE C D C EG BOTH EGHV0133 EGHV0061 BYPASS VALVE 1323 LIMITORQUE C D D EG BOTH EGHY0069A EGHV0069A SOLENOID VALVE 1314 CORR. J-605A D C D EG COLD EGHY0069B EGHV0069B SOLENOID VALVE 1314 CORR. J-605A D C D EG COLD EGHY0070A EGHV0070A SOLENOID VALVE 1314 CORR. J-605A D C D EG COLD EGHY0070B EGHV0070B SOLENOID VALVE 1314 J-605A D C D EG COLD 30 EGLI0001 CCW SURGE TK A LEVEL 3501 J-110 D D D EG BOTH EGLI0002 CCW SURGE TK B LEVEL 3501 J-110 D D D EG BOTH EGLT0001 CCW SURGE TK A LEVEL 1503 J-301 D D D EG BOTH 34 EGLT0002 CCW SURGE TK B LEVEL 1502 J-301 D D D EG BOTH 34 EGPT0077 CCW PMPS A&C DISCH PRESS 1406 J-301 D D D EG BOTH EGPT0078 CCW PMPS B&D DISCH PRESS 1401 J-301 D D D EG BOTH 33

11 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 12 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B EGTE0031 CCW HX A OUTLET TEMP 1406 J-558B D D D EG BOTH EGTE0032 CCW HX B OUTLET TEMP 1401 J-558B D D D EG BOTH 33 EGTI0031 CCW HX A OUTLET TEMP 3605 J-110 D D D EG BOTH EGTI0032 CCW HX B OUTLET TEMP 3605 J-110 D D D EG BOTH EGTT0031 CCW HX A OUTLET TEMP 3605 J-110 D D D EG BOTH EGTT0032 CCW HX B OUTLET TEMP 3605 J-110 D D D EG BOTH EGTV0029 CCW HX A BYPASS ISO 1406 J-605A D D D EG BOTH EGTV0029-E01 VALVE TERMINAL BOX 1406 E-028 D D D EG BOTH EGTV0030 CCW HX B BYPASS ISO 1401 J-605A D D D EG BOTH 33 EGTV0030-E01 VALVE TERMINAL BOX 1401 E-028 D D D EG BOTH 33 EGTY0029A EGTV0029 SOLENOID VALVE 1406 J-605A D D D EG BOTH EGTY0030A EGTV0030 SOLENOID VALVE 1401 J-605A D D D EG BOTH 33 EGZS0029 EGTV0029 LIMIT SWITCH 1406 J-605A D D D EG BOTH EGZS0030 EGTV0030 LIMIT SWITCH 1401 J-605A D D D EG BOTH 33 EGZS0069A EGHV0069A LIMIT SWITCH 1314 CORR. J-605A D C D EG COLD EGZS0069B EGHV0069B LIMIT SWITCH 1314 CORR. J-605A D C D EG COLD EGZS0070A EGHV0070A LIMIT SWITCH 1314 CORR. J-605A D C D EG COLD EGZS0070B EGHV0070B LIMIT SWITCH 1314 J-605A D C D EG COLD 30 EJFIS0610 RHR PUMP A MIN. FLOW INDICATING SWITCH 1301 WEST ESE-40A D D D EJ COLD EJLI0007 CTMT RECIRC SUMP A LEV 3501 J-110 D D D EJ --- 25 EJLI0008 CTMT RECIRC SUMP B LEV 3501 J-110 D D D EJ --- 25 EJLR0006 CTMT RECIRC SUMP LEV 3501 J-110 D D D EJ --- 25 EMFI0917A CHARGING PUMP DISCHARGE FLOW 3501 ESE-14 D D D EM BOTH EMFI0917B CHARGING PUMP DISCHARGE FLOW 3501 ESE-14 D D D EM BOTH EMFS0917C CHARGING PUMP DISCHARGE MINI FLOW SWITCH 1126 ESE-40A C D D EM BOTH EMFS0917D CHARGING PUMP DISCHARGE MINI FLOW SWITCH 1126 ESE-40A C D D EM BOTH EMFT0917A CHARGING PUMP TO BIT FLOW TRANSMITTER 1126 ESE-4 C D D EM BOTH EMFT0917B CHARGING PUMP TO BIT FLOW TRANSMITTER 1126 ESE-4 C D D EM BOTH EMHS8843 LOCAL CONTROL STATION 1409 E-028 C D D EM BOTH EMHV8924 RHR TO CVCS AND SI PUMPS ISOL VALVE 1108 LIMITORQUE C C C EM --- 28 EMTE0011 DPEM01A INBOARD BEARING TEMPERATURE 1113 M-721 C D D EM --- 29 EMTE0012 DPEM01A OUTBOARD BEARING TEMPERATURE 1113 M-721 C D D EM --- 29 EMTE0014 DPEM01B INBOARD BEARING TEMPERATURE 1108 M-721 C D D EM --- 28 EMTE0015 DPEM01B OUTBOARD BEARING TEMPERATURE 1108 M-721 C D D EM --- 28 ENLI0017 SPRAY ADD TANK LEVEL 3501 J-110 D D D EN ---

ENLI0019 SPRAY ADD TANK LEVEL 3501 J-110 D D D EN ---

ENZS0097 SPRAY ADDITIVE TANK DISC VALVE POSITION 1315 M-221 C C D EN --- 30 EPHV8808B ACCUMULATOR TANK B ISOLATION VALVE 2000 LIMITORQUE C D C EP COLD EPHV8808C ACCUMULATOR TANK C ISOLATION VALVE 2000 LIMITORQUE C D C EP COLD EPZS8808BB ACCUMULATOR TANK B ISOLATION VALVE LIMIT SWITCH 2000 HE-3 C D C EP COLD EPZS8808BB-E01 ACCUMULATOR TANK B ISOL VLV LS CONNECTOR 2000 HE-8 C D C EP COLD EPZS8808BB-E02 VALVE TERMINAL BOX 2000 E-028 C D C EP COLD EPZS8808CB ACCUMULATOR TANK C ISOLATION VALVE LIMIT SWITCH 2000 HE-3 C D C EP COLD EPZS8808CB-E01 ACCUMULATOR TANK C ISOL VLV LS CONNECTOR 2000 HE-8 C D C EP COLD EPZS8808CB-E02 VALVE TERMINAL BOX 2000 E-028 C D C EP COLD FC219 AFP TURBINE GAUGE AND CONTROL PANEL 1331 M-021 D C D FC BOTH FCFV0310-E01 VALVE TERMINAL BOX 1207 E-028 C D D FC --- 32

12 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 13 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B FCFV0313 TURBINE SPEED-GOVERNING VALVE 1331 M-021 D C D FC BOTH FCFY0310 FCFV0310 SOLENOID VALVE 1207 J-601 C D D FC --- 32 FCHIK0313A AUX FP TURB SPEED CTRL 3501 J-110 D D D FC BOTH FCHIK0313B AUX FDWTR PMP SPEED GOVERNOR 1413 J-110 D D D FC BOTH FCHV0312 TURBINE MANUAL TRIP AND THROTTLE VALVE 1331 M-021 D C D FC BOTH FCZS0310 FCFV0310 LIMIT SWITCH 1207 J-601 C D D FC --- 32 FEF01A TRAVELING WATER SCREEN A K105 M-020 D D D EF BOTH FEF01B TRAVELING WATER SCREEN B K104 M-020 D D D EF BOTH FEF02A SELF-CLEANING STRAINER A K105 M-154 D D D EF BOTH FEF02B SELF-CLEANING STRAINER B K104 M-154 D D D EF BOTH FGG02A FILTER-ABSORBER UNIT 6304 M-621 D D D GG ---

FGG02B FILTER-ABSORBER UNIT 6303 M-621 D D D GG ---

FGK01A FILTER ADSORBER UNIT 1512 M-621 D D D GK ---

FGK01B FILTER ADSORBER UNIT 1501 M-621 D D D GK ---

FGK02A CR PRESS FILTER ADSORBER UNIT 3416 M-621 D D D GK ---

FGK02B CR PRESS FILTER ADSORBER UNIT 3415 M-621 D D D GK ---

GDHIS0001B LOCAL CONTROL STATION K105 E-028 D D D GD ---

GDHIS0011B LOCAL CONTROL STATION K104 E-028 D D D GD ---

GDHS0011 LOCAL CONTROL STATION 3302 E-028 D D D GD ---

GDHS0011A LOCAL CONTROL STATION 3302 E-028B D D D GD ---

GDTE0001 ESW PMP RM TEMP 1A DAMPER K105 J-558B D D D GD BOTH GDTE0011 ESW PMP RM TEMP 1B DAMPER K104 J-558B D D D GD BOTH GDTT0001 ESW PMP RM TEMP 1A DAMPER 3605 J-110 D D D GD BOTH GDTT0011 ESW PMP RM TEMP 1B DAMPER 3605 J-110 D D D GD BOTH GDTZ0001A FLOW CONTROL DAMPER ACTUATOR - GDD0002 - ELC/HYD K105 M-627A D D D GD BOTH GDTZ0001B FLOW CONTROL DAMPER ACTUATOR - GDD0004 - ELC/HYD K105 M-627A D D D GD BOTH GDTZ0001C FLOW CONTROL DAMPER ACTUATOR - GDD0012 - ELC/HYD K105 M-627A D D D GD BOTH GDTZ0011A FLOW CONTROL DAMPER ACTUATOR - GDD0009 - ELC/HYD K104 M-627A D D D GD BOTH GDTZ0011B FLOW CONTROL DAMPER ACTUATOR - GDD0011 - ELC/HYD K104 M-627A D D D GD BOTH GDTZ0011C FLOW CONTROL DAMPER ACTUATOR - GDD0013 - ELC/HYD K104 M-627A D D D GD BOTH GEHZ0103 AUX BLDG ISO DAMPER ACTUATOR - GED0045 - ELEC 1504 M-627A D D D GE --- 34 GEHZ0104 AUX BLDG ISO DAMPER ACTUATOR - GED0044 - ELEC 1504 M-627A D D D GE --- 34 GFHIS0015 LOCAL CONTROL STATION 1326 E-028 D D D GF ---

GFHIS0016 LOCAL CONTROL STATION 1325 E-028 D D D GF ---

GFHZ0022 AUX BLDG ISO DAMPER ACTUATOR - GFD0024 - ELEC 1504 M-627A D D D GF --- 34 GFHZ0023 AUX BLDG ISO DAMPER ACTUATOR - GFD0025 - ELEC 1504 M-627A D D D GF --- 34 GFHZ0032A AUX BLDG ISO DAMPER ACTUATOR - GFD0068 - ELEC 1305 M-627A D D D GF ---

GFHZ0032B AUX BLDG ISO DAMPER ACTUATOR - GFD0060 - ELEC 1328 M-627A D D D GF ---

GFHZ0033A AUX BLDG ISO DAMPER ACTUATOR - GFD0069 - ELEC 1305 M-627A D D D GF ---

GFHZ0033B AUX BLDG ISO DAMPER ACTUATOR - GFD0061 - ELEC 1328 M-627A D D D GF ---

GGHIS0015B LOCAL CONTROL STATION 6304 E-028 D D D GG ---

GGHIS0021B LOCAL CONTROL STATION 6303 E-028 D D D GG ---

GGHIS0036B LOCAL CONTROL STATION 6203 E-028 D D D GG ---

GGHIS0037B LOCAL CONTROL STATION 6203 E-028 D D D GG ---

GGHS0050 LOCAL CONTROL STATION 6301 E-028 D D D GG --- 36 GGHS0051 LOCAL CONTROL STATION 6301 E-028 D D D GG --- 36 GGHZ0040 FUEL BLDG ISO DAMPER ACTUATOR - GGD0025 - ELEC 6304 M-627A D D D GG ---

GGHZ0041 AUX BLDG ISO DAMPER ACTUATOR - GGD0026 - ELEC 6304 M-627A D D D GG ---

13 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 14 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B GGHZ0042 AUX BLDG ISO DAMPER ACTUATOR - GGD0032 - ELEC 6304 M-627A D D D GG ---

GGHZ0043 FUEL BLDG ISO DAMPER ACTUATOR - GGD0018 - ELEC 6303 M-627A D D D GG ---

GGHZ0044 AUX BLDG ISO DAMPER ACTUATOR - GGD0019 - ELEC 6303 M-627A D D D GG ---

GGHZ0056 FUEL BLDG ISO DAMPER ACTUATOR - GGD0042 - ELEC 6304 M-627A D D D GG ---

GGHZ0057 FUEL BLDG ISO DAMPER ACTUATOR - GGD0043 - ELEC 6303 M-627A D D D GG ---

GGPDT0019 EMERGENCY FILTER ADSORBER UNIT A HEPA 6304 M-621 D D D GG ---

GGRE0027 FUEL BLDG EXHAUST RAD MONIT 6301 J-361 D D D GG --- 36 GGRE0028 FUEL BLDG EXHAUST RAD MONIT 6301 J-361 D D D GG --- 36 GGRT0027 GGRE0027 TRANSMITTER 6304 J-361 D D D GG ---

GGRT0028 GGRE0028 TRANSMITTER 6304 J-361 D D D GG ---

GGRV0027A SFP RAD MONIT INTAKE 6301 J-603A D D D GG --- 36 GGRV0027B SFP RAD MONIT RETURN 6301 J-603A D D D GG --- 36 GGRV0027C SPENT FUEL POOL RAD CNTRL VLV 6301 J-603A D D D GG --- 36 GGRV0027D SPENT FUEL POOL RAD CNTRL VLV 6301 J-603A D D D GG --- 36 GGRV0028A SFP RAD MONIT INTAKE 6301 J-603A D D D GG --- 36 GGRV0028B SFP RAD MONIT RETURN 6301 J-603A D D D GG --- 36 GGRV0028C SPENT FUEL POOL RAD CONT VLV 6301 J-603A D D D GG --- 36 GGRV0028D SPENT FUEL POOL RAD CONT VLV 6304 J-603A D D D GG ---

GGRZ0036 FUEL BLDG ISO DAMPER ACTUATOR - GGD0003 - ELEC 6203 M-627A D D D GG ---

GGRZ0037 FUEL BLDG ISO DAMPER ACTUATOR - GGD0004 - ELEC 6203 M-627A D D D GG ---

GGTE0016 FGG02A TEMPERATURE 6304 M-621 D D D GG ---

GGTE0022 FGG02B TEMPERATURE 6303 M-621 D D D GG ---

GGTT0016 GGTE0016 TRANSMITTER 6304 M-621 D D D GG ---

GGTT0022 GGTE0022 TRANSMITTER 6303 M-621 D D D GG ---

GK195A SGK05A CONTROL PANEL 3416 M-622.1A D D D GK BOTH GK195B SGK05A POWER PANEL 3416 M-622.1A D D D GK BOTH GK195C SGK05A POWER AND CONTROL PANEL 3416 M-622.1A D D D GK BOTH GK196A SGK05B CONTROL PANEL 3415 M-622.1A D D D GK BOTH GK196B SGK05B POWER PANEL 3415 M-622.1A D D D GK BOTH GK196C SGK05B POWER AND CONTROL PANEL 3415 M-622.1A D D D GK BOTH GK198A SGK04A CONTROL PANEL 1512 M-622.1A D D D GK BOTH GK198B SGK04A POWER PANEL 1512 M-622.1A D D D GK BOTH GK198C SGK04A POWER AND CONTROL PANEL 1512 M-622.1A D D D GK BOTH GK199A SGK04B CONTROL PANEL 1501 M-622.1A D D D GK BOTH GK199B SGK04B POWER PANEL 1501 M-622.1A D D D GK BOTH GK199C SGK04B POWER AND CONTROL PANEL 1501 M-622.1A D D D GK BOTH GKAE0002 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 1513 J-375A D D D GK --- 34 GKAE0003 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 1513 J-375A D D D GK --- 34 GKAI0002 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 3501 J-110 D D D GK ---

GKAI0003 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 3501 J-110 D D D GK ---

GKAT0002 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 1513 J-375A D D D GK --- 34 GKAT0003 CTRL BLDG SUP AIR CHLORINE (SPARED IN PLACE) 1513 J-375A D D D GK --- 34 GKHS0040 LOCAL CONTROL STATION 1501 E-028 D D D GK ---

GKHS0103 LOCAL CONTROL STATION 1501 E-028 D D D GK ---

GKHY0013A GKHZ0013A SOLENOID VALVE 1501 M-627A D D D GK ---

GKHY0013B GKHZ0013B SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0013C GKHZ0013C SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0013D GKHZ0013D SOLENOID VALVE 1513 M-627A D D D GK --- 34

14 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 15 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B GKHY0013E GKHZ0013E SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0013F GKHZ0013F SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0013G GKHZ0013G SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0013H GKHZ0013H SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0055A GKHZ0055A SOLENOID VALVE 3801 M-627A D D D GK ---

GKHY0055B GKHZ0055B SOLENOID VALVE 3801 M-627A D D D GK ---

GKHY0057A GKHZ0057A SOLENOID VALVE 3609 M-627A D D D GK ---

GKHY0057B GKHZ0057B SOLENOID VALVE 3609 M-627A D D D GK ---

GKHY0059A GKHZ0059A SOLENOID VALVE 3501 M-627A D D D GK ---

GKHY0059B GKHZ0059B SOLENOID VALVE 3501 M-627A D D D GK ---

GKHY0098A GKHZ0098A SOLENOID VALVE 3411 M-627A D D D GK ---

GKHY0098B GKHZ0098B SOLENOID VALVE 3412 M-627A D D D GK --- 35 GKHY0122A GKHZ0122A SOLENOID VALVE 3302 M-627A D D D GK ---

GKHY0122B GKHZ0122B SOLENOID VALVE 3302 M-627A D D D GK ---

GKHY0123A GKHZ0123A SOLENOID VALVE 3211 M-627A D D D GK ---

GKHY0123B GKHZ0123B SOLENOID VALVE 3218 M-627A D D D GK ---

GKHY0123C GKHZ0123C SOLENOID VALVE 3218 M-627A D D D GK ---

GKHY0184A GKHZ0184A SOLENOID VALVE 1501 M-627A D D D GK ---

GKHY0184B GKHZ0184B SOLENOID VALVE 1512 M-627A D D D GK ---

GKHY0184C GKHZ0184C SOLENOID VALVE 1513 M-627A D D D GK --- 34 GKHY0184D GKHZ0184D SOLENOID VALVE 1513 M-627A D D D GK --- 34 GKHZ0013A CTRL BLDG ISO DAMPER ACTUATOR - GKD0002 - PNEU 1501 M-627A D D D GK ---

GKHZ0013B CTRL BLDG ISO DAMPER ACTUATOR - GKD0018 - PNEU 1512 M-627A D D D GK ---

GKHZ0013C CTRL BLDG ISO DAMPER ACTUATOR - GKD0025 - PNEU 1512 M-627A D D D GK ---

GKHZ0013D CTRL BLDG ISO DAMPER ACTUATOR - GKD0279 - PNEU 1513 M-627A D D D GK --- 34 GKHZ0013E CTRL BLDG ISO DAMPER ACTUATOR - GKD0283 - PNEU 1512 M-627A D D D GK ---

GKHZ0013F CTRL BLDG ISO DAMPER ACTUATOR - GKD0309 - PNEU 1512 M-627A D D D GK ---

GKHZ0013G CTRL BLDG ISO DAMPER ACTUATOR - GKD0311 - PNEU 1512 M-627A D D D GK ---

GKHZ0013H CTRL BLDG ISO DAMPER ACTUATOR - GKD0313 - PNEU 1512 M-627A D D D GK ---

GKHZ0019A CR FILT SYS ISO DAMPER ACTUATOR - GKD0082 - ELEC 1512 M-627A D D D GK ---

GKHZ0019B CR FILT SYS ISO DAMPER ACTUATOR - GKD0083 - ELEC 1512 M-627A D D D GK ---

GKHZ0019C A/C SYS ISO DAMPER ACTUATOR - GKD0286 - ELEC 1512 M-627A D D D GK ---

GKHZ0019D A/C SYS ISO DAMPER ACTUATOR - GKD0285 - ELEC 1512 M-627A D D D GK ---

GKHZ0029A A/C SYS ISO DAMPER ACTUATOR - GKD0080 - ELEC 1512 M-627A D D D GK BOTH GKHZ0029B A/C SYS ISO DAMPER ACTUATOR - GKD0081 - ELEC 1512 M-627A D D D GK BOTH GKHZ0030A CR FILT SYS ISO DAMPER ACTUATOR - GKD0086 - ELEC 1501 M-627A D D D GK ---

GKHZ0030B CR FILT SYS ISO DAMPER ACTUATOR - GKD0087 - ELEC 1501 M-627A D D D GK ---

GKHZ0030C A/C SYS ISO DAMPER ACTUATOR - GKD0319 - ELEC 1501 M-627A D D D GK ---

GKHZ0030D A/C SYS ISO DAMPER ACTUATOR - GKD0318 - ELEC 1501 M-627A D D D GK ---

GKHZ0040A A/C UNIT ISO DAMPER ACTUATOR - GKD0084 - ELEC 1501 M-627A D D D GK BOTH GKHZ0040B CTRL ROOM ISO DAMPER ACTUATOR - GKD0085 - ELEC 1501 M-627A D D D GK BOTH GKHZ0055A CSR ISO DAMPER ACTUATOR - GKD0004 - PNEU 3801 M-627A D D D GK ---

GKHZ0055B CSR ISO DAMPER ACTUATOR - GKD0016 - PNEU 3801 M-627A D D D GK ---

GKHZ0057A CTRL BLDG ISO DAMPER ACTUATOR - GKD0005 - PNEU 3609 M-627A D D D GK ---

GKHZ0057B CTRL BLDG ISO DAMPER ACTUATOR - GKD0015 - PNEU 3609 M-627A D D D GK ---

GKHZ0059A CSR ISO DAMPER ACTUATOR - GKD0006 - PNEU 3501 M-627A D D D GK ---

GKHZ0059B CSR ISO DAMPER ACTUATOR - GKD0014 - PNEU 3501 M-627A D D D GK ---

GKHZ0075A PRESS SYS ISO DAMPER ACTUATOR - GKD0105 - ELEC 3416 M-627A D D D GK ---

15 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 16 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B GKHZ0075B PRESS SYS ISO DAMPER ACTUATOR - GKD0317 - ELEC 3416 M-627A D D D GK ---

GKHZ0075C CTRL BLDG ISO DAMPER ACTUATOR - GKD0323 - ELEC 3301 M-627A D D D GK ---

GKHZ0083A PRESS SYS ISO DAMPER ACTUATOR - GKD0088 - ELEC 3415 M-627A D D D GK ---

GKHZ0083B PRESS SYS ISO DAMPER ACTUATOR - GKD0292 - ELEC 3415 M-627A D D D GK ---

GKHZ0083C CTRL BLDG ISO DAMPER ACTUATOR - GKD0320 - ELEC 3302 M-627A D D D GK ---

GKHZ0098A SWGR ROOM ISO DAMPER ACTUATOR - GKD0007 - PNEU 3411 M-627A D D D GK ---

GKHZ0098B BATTERY RM ISO DAMPER ACTUATOR - GKD0013 - PNEU 3412 M-627A D D D GK --- 35 GKHZ0122A ESF SWGR RM ISO DAMPER ACTUATOR - GKD0008 - PNEU 3302 M-627A D D D GK ---

GKHZ0122B ESF SWGR RM ISO DAMPER ACTUATOR - GKD0012 - PNEU 3302 M-627A D D D GK ---

GKHZ0123A ACCESS CTRL ISO DAMPER ACTUATOR - GKD0009 - PNEU 3211 M-627A D D D GK ---

GKHZ0123B ACCESS CTRL ISO DAMPER ACTUATOR - GKD0219 - PNEU 3218 M-627A D D D GK ---

GKHZ0123C ACCESS CTRL ISO DAMPER ACTUATOR - GKD0220 - PNEU 3218 M-627A D D D GK ---

GKHZ0152 CTRL BLDG ISO DAMPER ACTUATOR - GKD0130 - ELEC 1513 M-627A D D D GK --- 34 GKHZ0153 CTRL BLDG ISO DAMPER ACTUATOR - GKD0131 - ELEC 1513 M-627A D D D GK --- 34 GKHZ0154 ACCESS CTRL ISO DAMPER ACTUATOR - GKD0132 - ELEC 1504 M-627A D D D GK --- 34 GKHZ0155 ACCESS CTRL ISO DAMPER ACTUATOR - GKD0133 - ELEC 1504 M-627A D D D GK --- 34 GKHZ0160 CR PRESS SYS ISO DAMPER ACTUATOR - GKD0179 - ELC 1512 M-627A D D D GK ---

GKHZ0161 CR PRESS SYS ISO DAMPER ACTUATOR - GKD0181 - ELC 1512 M-627A D D D GK ---

GKHZ0172A CTRL BLDG ISO DAMPER ACTUATOR - GKD0198 - ELEC 3101 M-627A D D D GK ---

GKHZ0172B CTRL BLDG ISO DAMPER ACTUATOR - GKD0203 - ELEC 3101 M-627A D D D GK ---

GKHZ0173A CTRL BLDG ISO DAMPER ACTUATOR - GKD0199 - ELEC 3101 M-627A D D D GK ---

GKHZ0173B CTRL BLDG ISO DAMPER ACTUATOR - GKD0202 - ELEC 3101 M-627A D D D GK ---

GKHZ0174A CTRL BLDG ISO DAMPER ACTUATOR - GKD0212 - ELEC 3224 M-627A D D D GK ---

GKHZ0174B CTRL BLDG ISO DAMPER ACTUATOR - GKD0209 - ELEC 3222 M-627A D D D GK ---

GKHZ0175A CTRL BLDG ISO DAMPER ACTUATOR - GKD0213 - ELEC 3224 M-627A D D D GK ---

GKHZ0175B CTRL BLDG ISO DAMPER ACTUATOR - GKD0208 - ELEC 3222 M-627A D D D GK ---

GKHZ0184A CTRL BLDG ISO DAMPER ACTUATOR - GKD0300 - PNEU 1501 M-627A D D D GK ---

GKHZ0184B CTRL BLDG ISO DAMPER ACTUATOR - GKD0301 - PNEU 1512 M-627A D D D GK ---

GKHZ0184C CTRL BLDG ISO DAMPER ACTUATOR - GKD0310 - PNEU 1513 M-627A D D D GK --- 34 GKHZ0184D CTRL BLDG ISO DAMPER ACTUATOR - GKD0312 - PNEU 1513 M-627A D D D GK --- 34 GKME0076 MOISTURE SENSOR ELEMENT (DISABLED) 3416 M-621 D D D GK ---

GKME0084 MOISTURE SENSOR ELEMENT (DISABLED) 3415 M-621 D D D GK ---

GKMT0076 FGK02A MOISTURE TRANS. (DISABLED) 3416 M-621 D D D GK ---

GKMT0076A FGK02A MOISTURE TRANS. (DISABLED) 3416 M-621 D D D GK ---

GKMT0084 FGK02B MOISTURE TRANS. (DISABLED) 3415 M-621 D D D GK ---

GKMT0084A FGK02B MOISTURE TRANS. (DISABLED) 3415 M-621 D D D GK ---

GKRE0004 CTRL BLDG SUP AIR RAD MONIT 1513 J-361 D D D GK --- 34 GKRE0005 CTRL BLDG SUP AIR RAD MONIT 1513 J-361 D D D GK --- 34 GKRT0004 GKRE0004 TRANSMITTER 1513 J-361 D D D GK --- 34 GKRT0005 GKRE0005 TRANSMITTER 1513 J-361 D D D GK --- 34 GLHIS0002 LOCAL CONTROL STATION 1406 E-028 D D D GL ---

GLHIS0023 LOCAL CONTROL STATION 1401 E-028 D D D GL --- 33 GLHZ0032-1 AUX BLDG ISO DAMPER ACTUATOR - GLD0052 - ELEC 1504 M-627A D D D GL --- 34 GLHZ0032-2 AUX BLDG ISO DAMPER ACTUATOR - GLD0052 - ELEC 1504 M-627A D D D GL --- 34 GLHZ0033-1 AUX BLDG ISO DAMPER ACTUATOR - GLD0053 - ELEC 1504 M-627A D D D GL --- 34 GLHZ0033-2 AUX BLDG ISO DAMPER ACTUATOR - GLD0053 - ELEC 1504 M-627A D D D GL --- 34 GLHZ0073 AUX BLDG ISO DAMPER ACTUATOR - GLD0036 - ELEC 1102 M-627A D C D GL --- 27 GLHZ0074 AUX BLDG ISO DAMPER ACTUATOR - GLD0037 - ELEC 1102 M-627A D C D GL --- 27

16 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 17 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B GLHZ0075 AUX BLDG ISO DAMPER ACTUATOR - GLD0038 - ELEC 1102 M-627A D C D GL --- 27 GLHZ0076 AUX BLDG ISO DAMPER ACTUATOR - GLD0039 - ELEC 1102 M-627A D C D GL --- 27 GLHZ0080 AUX BLDG ISO DAMPER ACTUATOR - GLD0157 - ELEC 1406 M-627A D D D GL BOTH GLHZ0081 AUX BLDG ISO DAMPER ACTUATOR - GLD0156 - ELEC 1406 M-627A D D D GL BOTH GMHS0011B LOCAL CONTROL STATION 5201 E-028 D D D GM ---

GMHS0019B LOCAL CONTROL STATION 5201 E-028 D D D GM ---

GMHY0009 GMHZ0009 SOLENOID VALVE 5203 M-627A D D D GM ---

GMHY0019 GMHZ0019 SOLENOID VALVE 5201 M-627A D D D GM ---

GMHZ0009 D.G. ROOM ISO DAMPER ACTUATOR - GMD0005 - PNEU 5203 M-627A D D D GM ---

GMHZ0019 D.G. ROOM ISO DAMPER ACTUATOR - GMD0010 - PNEU 5201 M-627A D D D GM ---

GMTE0001 DIESEL GEN VENT SUPPLY FAN 1A 5203 J-558B D D D GM ---

GMTE0011 DIESEL GEN VENT SUPPLY FAN 1B 5201 J-558B D D D GM ---

GMTT0001 DIESEL GEN VENT SUPPLY FAN 1A 3605 J-110 D D D GM ---

GMTT0011 DIESEL GEN VENT SUPPLY FAN 1B 3605 J-110 D D D GM ---

GMTZ0001A FLOW CTRL DAMPER ACTUATOR - GMD0002 - ELEC/HYD 5203 M-627A D D D GM ---

GMTZ0001B FLOW CTRL DAMPER ACTUATOR - GMD0003 - ELEC/HYD 5203 M-627A D D D GM ---

GMTZ0011A FLOW CTRL DAMPER ACTUATOR - GMD0007 - ELEC/HYD 5201 M-627A D D D GM ---

GMTZ0011B FLOW CTRL DAMPER ACTUATOR - GMD0008 - ELEC/HYD 5201 M-627A D D D GM ---

GNPI0934 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN ---

GNPI0935 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN ---

GNPI0936 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN ---

GNPI0937 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN ---

GNPI0938 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN HOT 25 GNPI0939 CONTAINMENT ATM PRESSURE 3501 ESE-14 D D D GN HOT 25 GNPT0934 CONTAINMENT PRESSURE SENSOR 1409 J-301-P02 D D D GN ---

GNPT0935 CONTAINMENT PRESSURE TRANSMITTER 1410 ESE-4A D D D GN ---

GNPT0936 CONTAINMENT PRESSURE TRANSMITTER 1409 ESE-4A D D D GN ---

GNPT0937 CONTAINMENT PRESSURE TRANSMITTER 1410 ESE-4A D D D GN ---

GNPT0938 CONTAINMENT PRESSURE TRANSMITTER WIDE RANGE 1410 ESE-4A D D D GN HOT 25 GNPT0939 CONTAINMENT PRESSURE TRANSMITTER WIDE RANGE 1409 ESE-4A D D D GN HOT 25 GNTI0060 CTMT ATMOS TEMP 3501 J-110 D D D GN BOTH GNTI0061 CTMT ATMOS TEMP 3501 J-110 D D D GN BOTH GNTI0062 CTMT ATMOS TEMP 3501 J-110 D D D GN BOTH GNTI0063 CTMT ATMOS TEMP 3501 J-110 D D D GN BOTH GNTR0063 CTMT ATMOS TEMP 3501 J-110 D D D GN BOTH GNTT0060 CTMT COOLER A TEMP 3605 J-110 D D D GN BOTH GNTT0061 CTMT COOLER B TEMP 3605 J-110 D D D GN BOTH GNTT0062 CTMT COOLER C TEMP 3605 J-110 D D D GN BOTH GNTT0063 CTMT COOLER D TEMP 3605 J-110 D D D GN BOTH GS001A RECOMBINER POWER PANEL 3301 M-637 D D D GS ---

GS001B RECOMBINER POWER PANEL 3302 M-637 D D D GS ---

GS065A H2 ANALYZER CONTROL PANEL 3605 J-359 D D D GS ---

GS065AA RECOMBINER CONTROL PANEL 3605 M-637 D D D GS ---

GS065B H2 ANALYZER CONTROL PANEL 3605 J-359 D D D GS ---

GS065BA RECOMBINER CONTROL PANEL 3605 M-637 D D D GS ---

GSAI0010 HYDROGEN ANALYZER 2B 3501 J-110 D D D GS ---

GSAI0019 HYDROGEN ANALYZER 2A 3501 J-110 D D D GS ---

17 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 18 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B GSAR0010 HYDROGEN ANALYZER 3501 J-110 D D D GS ---

GSAT0010 HYDROGEN ANALYZER 2B ANALYSIS TRANSMITTER 3605 J-359 D D D GS ---

GSAT0019 HYDROGEN ANALYZER 2A ANALYSIS TRANSMITTER 3605 J-359 D D D GS ---

GTHZ0028 AUX BLDG ISO DAMPER ACTUATOR - GTD0011 - ELEC 1504 M-627A D D D GT --- 34 GTHZ0029 AUX BLDG ISO DAMPER ACTUATOR - GTD0012 - ELEC 1504 M-627A D D D GT --- 34 GTRE0022 CTMT PURGE EXHAUST RAD MONIT 1507 J-361 C D D GT --- 34 GTRE0031 CTMT ATMOSPHERE RAD MONIT 1507 J-361 C D D GT --- 34 GTRE0032 CTMT ATMOSPHERE RAD MONIT 1506 J-361 C D D GT --- 34 GTRE0033 CTMT PURGE EXH RAD MONIT 1507 J-361 C D D GT --- 34 GTRIC0059 CTMT HRRM CONTROL/DISPLAY MODULE 3501 J-361A D D D GT ---

GTRIC0060 CTMT HRRM CONTROL/DISPLAY MODULE 3501 J-361A D D D GT ---

GTRR0060 CTMT HIGH RANGE AREA RADN RECORDER 3501 J-110 D D D GT --- 25 GTRT0022 GTRE0022 TRANSMITTER 1507 J-361 C D D GT --- 34 GTRT0031 GTRE0031 TRANSMITTER 1507 J-361 C D D GT --- 34 GTRT0032 GTRE0032 TRANSMITTER 1506 J-361 C D D GT --- 34 GTRT0033 GTRE0033 TRANSMITTER 1507 J-361 C D D GT --- 34 GTRT0059 CTMT HIGH RANGE AREA RADN MON 1512 J-361A D D D GT --- 25 GTRT0060 CTMT HIGH RANGE AREA RADN MON 1501 J-361A D D D GT --- 25 GTRV0022A CTMT PURGE EXHAUST 1507 J-603A C D D GT --- 34 GTRV0022B CTMT PURGE EXHAUST 1504 J-603A D D D GT --- 34 GTRV0033A CTMT PURGE EXHAUST 1507 J-603A C D D GT --- 34 GTRV0033B CTMT PURGE EXHAUST 1504 J-603A D D D GT --- 34 JELI0012A EMER FUEL OIL DAY TK A LEV 3501 J-110 D D D JE BOTH JELI0012B EMER FUEL OIL DAY TK A LEV 5203 J-110 D D D JE BOTH JELI0032A EMER FUEL OIL DAY TK B LEV 3501 J-110 D D D JE BOTH JELI0032B EMER FUEL OIL DAY TK B LEV 5201 J-110 D D D JE BOTH JELT0001 EMER FUEL OIL DAY TK A LEV 5203 J-301 D D D JE BOTH JELT0012 EMER FUEL OIL DAY TK A LEV 5203 J-301 D D D JE BOTH JELT0021 EMER FUEL OIL DAY TK B LEV 5201 J-301 D D D JE BOTH JELT0032 EMER FUEL OIL DAY TK B LEV 5201 J-301 D D D JE BOTH KFC02 AUX FEED PUMP TURBINE 1331 M-021 D D C FC BOTH KJ121 DIESEL GAUGE AND CONTROL PANEL 5203 M-018 D D D KJ BOTH KJ122 DIESEL GAUGE AND CONTROL PANEL 5201 M-018 D D D KJ BOTH KJHS0110 CONTROL ROOM FIRE ISO SWITCH 5201 M-018 D D D KJ ---

KJLI0031 L.O. LEVEL CONTROL TANK INDICATOR 5203 M-018 D D D KJ BOTH KJLI0038 L.O. AUX. TANK LEVEL INDICATOR 5203 M-018 D D D KJ BOTH KJLI0131 L.O. LEVEL CONTROL TANK INDICATOR 5201 M-018 D D D KJ BOTH KJLI0138 L.O. AUX. TANK LEVEL INDICATOR 5201 M-018 D D D KJ BOTH KJPS0062 JACKET WATER BACKUP TO ELECT SPEED SWITCH 5203 M-018 D D D KJ BOTH KJPS0162 JACKET WATER BACKUP TO ELECT SPEED SWITCH 5201 M-018 D D D KJ BOTH KJPSH0023A HIGH CRANKCASE PRESSURE 5203 M-018 D D D KJ BOTH KJPSH0023B HIGH CRANKCASE PRESSURE 5203 M-018 D D D KJ BOTH KJPSH0023C HIGH CRANKCASE PRESSURE 5203 M-018 D D D KJ BOTH KJPSH0023D HIGH CRANKCASE PRESSURE 5203 M-018 D D D KJ BOTH KJPSH0123A HIGH CRANKCASE PRESS 5201 M-018 D D D KJ BOTH KJPSH0123B HIGH CRANKCASE PRESS 5201 M-018 D D D KJ BOTH KJPSH0123C HIGH CRANKCASE PRESS 5201 M-018 D D D KJ BOTH KJPSH0123D HIGH CRANKCASE PRESS 5201 M-018 D D D KJ BOTH

18 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 19 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B KJPSHL0002A AIR COMPR. A START/STOP PRESS. SWITCH 5203 M-018 D D D KJ BOTH KJPSHL0002B AIR COMPR. B START/STOP PRESS. SWITCH 5203 M-018 D D D KJ BOTH KJPSHL0102A AIR COMPR. A START/STOP PRESS. SWITCH 5201 M-018 D D D KJ BOTH KJPSHL0102B AIR COMPR. B START/STOP PRESS. SWITCH 5201 M-018 D D D KJ BOTH KJPSL0026A LOW LUBE OIL PRESS 5203 M-018 D D D KJ BOTH KJPSL0026B LOW LUBE OIL PRESS 5203 M-018 D D D KJ BOTH KJPSL0026C LOW LUBE OIL PRESS 5203 M-018 D D D KJ BOTH KJPSL0026D LOW LUBE OIL PRESS 5203 M-018 D D D KJ BOTH KJPSL0126A LOW LUBE OIL PRESS 5201 M-018 D D D KJ BOTH KJPSL0126B LOW LUBE OIL PRESS 5201 M-018 D D D KJ BOTH KJPSL0126C LOW LUBE OIL PRESS 5201 M-018 D D D KJ BOTH KJPSL0126D LOW LUBE OIL PRESS 5201 M-018 D D D KJ BOTH KJPV0001A AIR START SOL VLV 1 5203 M-018 D D D KJ BOTH KJPV0001B AIR START SOL VLV 2 5203 M-018 D D D KJ BOTH KJPV0008 SHUTDOWN AIR SOL VLV 5203 M-018 D D D KJ BOTH KJPV0101A AIR START SOL VLV 1 5201 M-018 D D D KJ BOTH KJPV0101B AIR START SOL VLV 2 5201 M-018 D D D KJ BOTH KJPV0108 SHUTDOWN AIR SOL VLV 5201 M-018 D D D KJ BOTH KJTCV0034 LUBE OIL COOLER TEMP CTRL VLV 5203 M-018 D D D KJ BOTH KJTCV0056 INTERCOOLER HEAT EXCHANGER TEMP CTRL VLV 5203 M-018 D D D KJ BOTH KJTCV0060 JACKET WATER HEAT EXCHANGER TEMP CTRL VLV 5203 M-018 D D D KJ BOTH KJTCV0134 LUBE OIL COOLER TEMP CTRL VLV 5201 M-018 D D D KJ BOTH KJTCV0156 INTERCOOLER HEAT EXCHANGER TEMP CTRL VLV 5201 M-018 D D D KJ BOTH KJTCV0160 JACKET WATER HEAT EXCHANGER TEMP CTRL VLV 5201 M-018 D D D KJ BOTH KJTSH0059A HIGH JACKET WATER TEMP 5203 M-018 D D D KJ BOTH KJTSH0059B HIGH JACKET WATER TEMP 5203 M-018 D D D KJ BOTH KJTSH0059C HIGH JACKET WATER TEMP 5203 M-018 D D D KJ BOTH KJTSH0059D HIGH JACKET WATER TEMP 5203 M-018 D D D KJ BOTH KJTSH0159A HIGH JACKET WATER TEMP 5201 M-018 D D D KJ BOTH KJTSH0159B HIGH JACKET WATER TEMP 5201 M-018 D D D KJ BOTH KJTSH0159C HIGH JACKET WATER TEMP 5201 M-018 D D D KJ BOTH KJTSH0159D HIGH JACKET WATER TEMP 5201 M-018 D D D KJ BOTH LELE0105 DIESEL GEN BLDG SUMP 5203 J-481 D D D LE BOTH LELE0106 DIESEL GEN BLDG SUMP 5201 J-481 D D D LE BOTH LELI0105 DIESEL GEN BLDG SUMP 3501 J-200 D D D LE BOTH LELI0106 DIESEL GEN BLDG SUMP 3501 J-200 D D D LE BOTH LELIT0105 DIESEL GEN BLDG SUMP 3605 J-481 D D D LE BOTH LELIT0106 DIESEL GEN BLDG SUMP 3605 J-481 D D D LE BOTH LFLE0124 CONTROL BLDG FL EQUIP DRAIN 3101 J-481 D D D LF ---

LFLE0125 CONTROL BLDG FL EQUIP DRAIN 3101 J-481 D D D LF ---

LFLI0009 CTMT NORMAL SUMP B LEVEL 3501 J-110 D D D LF --- 25 LFLI0010 CTMT NORMAL SUMP A LEVEL 3501 J-110 D D D LF --- 25 LFLI0101 RHR PMP ROOM SUMP LEVEL 3501 J-110 D D D LF COLD LFLI0102 RHR PMP ROOM SUMP LEVEL 3501 J-110 D D D LF COLD LFLI0103 AUX BLDG SUMP LEVEL 3501 J-110 D D D LF ---

LFLI0104 AUX BLDG SUMP LEVEL 3501 J-110 D D D LF ---

LFLI0124 CONTROL BLDG FL EQUIP DRAIN 3501 J-200 D D D LF ---

LFLI0125 CONTROL BLDG FL EQUIP DRAIN 3501 J-200 D D D LF ---

19 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 20 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B LFLIT0009 CTMT NORMAL SUMP 3605 J-481 D D D LF --- 25 LFLIT0010 CTMT NORMAL SUMP 3605 J-481 D D D LF --- 25 LFLIT0101 RHR PMP ROOM LEAKAGE LEVEL 3605 J-481 D D D LF COLD LFLIT0102 RHR PMP ROOM LEAKAGE LEVEL 3605 J-481 D D D LF COLD LFLIT0103 AUX BLDG LEAKAGE LEVEL 3605 J-481 D D D LF ---

LFLIT0104 AUX BLDG LEAKAGE LEVEL 3605 J-481 D D D LF ---

LFLIT0124 CONTROL BLDG FL EQUIP DRAIN 3605 J-481 D D D LF ---

LFLIT0125 CONTROL BLDG FL EQUIP DRAIN 3605 J-481 D D D LF ---

NB001 4.16 KV SWITCHGEAR 3301 E-009 D D D NB BOTH NB002 4.16 KV SWITCHGEAR 3302 E-009 D D D NB BOTH NBEI0001 4 KV BUS NB01 VOLTS 3501 J-200 D D D NB ---

NBEI0002 4 KV BUS NB02 VOLTS 3501 J-200 D D D NB ---

NBEI0003 4 KV BUS NB01 SYNCHROSCOPE 3501 J-200 D D D NB ---

NBEI0004 4 KV BUS NB02 SYNCHROSCOPE 3501 J-200 D D D NB ---

NE001 DIESEL GENERATOR 5203 M-018 D D D NE BOTH NE002 DIESEL GENERATOR 5201 M-018 D D D NE BOTH NE106 CONTROL & RELAY PANEL 5201 M-018 D D D NE BOTH NE107 CONTROL & RELAY PANEL 5203 M-018 D D D NE BOTH NF039A LOAD SHED/SEQ PANEL 3605 E-092 D D D NF BOTH NF039B LOAD SHED/SEQ PANEL 3605 E-092 D D D NF BOTH NF039C LOAD SHED/SEQ PANEL 3605 E-092 D D D NF BOTH NG001 LOAD CENTER 3301 E-017 D D D NG BOTH NG001A MCC 3301 E-018 D D D NG BOTH NG001B MCC 1410 E-018 D D D NG BOTH 12 NG001T MCC 1410 E-018 D D D NG BOTH 12 NG002 LOAD CENTER 3302 E-017 D D D NG BOTH NG002A MCC 3302 E-017 D D D NG BOTH NG002B MCC 1409 E-018 D D D NG BOTH 12 NG002T MCC 1409 E-018 D D D NG BOTH 12 NG003 LOAD CENTER 3301 E-017 D D D NG BOTH NG003C MCC 1512 E-018 D D D NG BOTH NG003D MCC 5203 E-018 D D D NG BOTH NG003T MCC 1410 E-018 D D D NG BOTH 12 NG004 LOAD CENTER 3302 E-017 D D D NG BOTH NG004C MCC 1501 E-018 D D D NG BOTH NG004D MCC 5201 E-018 D D D NG BOTH NG004T MCC 1409 E-018 D D D NG BOTH 12 NG005E MCC K105 E-018 D D D NG BOTH NG006E MCC K104 E-018 D D D NG BOTH NK001 125 VDC SWITCHBOARD 3408 E-020 D D D NK BOTH NK002 125 VDC SWITCHBOARD 3410 E-020 D D D NK BOTH NK003 125 VDC SWITCHBOARD 3414 E-020 D D D NK BOTH NK004 125 VDC SWITCHBOARD 3404 E-020 D D D NK BOTH NK011 BATTERY 3407 E-050A D D D NK BOTH NK012 BATTERY 3411 E-050A D D D NK BOTH NK013 BATTERY 3413 E-050A D D D NK BOTH NK014 BATTERY 3405 E-050A D D D NK BOTH NK021 CHARGER 3408 E-051 D D D NK BOTH

20 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 21 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B NK022 CHARGER 3410 E-051 D D D NK BOTH NK023 CHARGER 3414 E-051 D D D NK BOTH NK024 CHARGER 3404 E-051 D D D NK BOTH NK025 SPARE CHARGER 3301 E-051 D D D NK ---

NK026 SPARE CHARGER 3302 E-051A D D D NK ---

NK041 125 VDC SWITCHBOARD 3408 E-020 D D D NK BOTH NK042 125 VDC SWITCHBOARD 3410 E-020 D D D NK BOTH NK043 125 VDC SWITCHBOARD 3414 E-020 D D D NK BOTH NK044 125 VDC SWITCHBOARD 3404 E-020 D D D NK BOTH NK051 125 VDC SWITCHBOARD 3408 E-020 D D D NK BOTH NK051A LIGHTING PANEL 3408 E-020 D D D NK BOTH NK054 125 VDC SWITCHBOARD 3404 E-020 D D D NK BOTH NK071 TRANSFER SWITCH 3408 E-051B D D D NK BOTH NK072 TRANSFER SWITCH 3410 E-051B D D D NK BOTH NK073 TRANSFER SWITCH 3414 E-051B D D D NK BOTH NK074 TRANSFER SWITCH 3404 E-051B D D D NK BOTH NK075 SPARE CHARGER TRANSFER SWITCH 3301 E-051B D D D NK ---

NK076 SPARE CHARGER TRANSFER SWITCH 3302 E-051B D D D NK ---

NK077 SPARE CHARGER TRANSFER SWITCH 3301 E-051B D D D NK ---

NK078 SPARE CHARGER TRANSFER SWITCH 3302 E-051B D D D NK ---

NK079 MANUAL TRANSFER SWITCH 3301 M-766A D D D NK ---

NK080 MANUAL TRANSFER SWITCH 3302 M-766A D D D NK ---

NKEI0001 NK01 125 VDC BUS VOLTS 3501 J-200 D D D NK ---

NKEI0002 NK02 125 VDC BUS VOLTS 3501 J-200 D D D NK ---

NKEI0003 NK03 125 VDC BUS VOLTS 3501 J-200 D D D NK ---

NKEI0004 NK04 125 VDC BUS VOLTS 3501 J-200 D D D NK ---

NKII0001 NK21 BAT CHARGER AMPS 3501 J-200 D D D NK ---

NKII0002 NK11 BAT AMPS 3501 J-200 D D D NK ---

NKII0003 NK22 BAT CHARGER AMPS 3501 J-200 D D D NK ---

NKII0004 NK12 BAT AMPS 3501 J-200 D D D NK ---

NKII0005 NK23 BAT CHARGER AMPS 3501 J-200 D D D NK ---

NKII0006 NK13 BAT AMPS 3501 J-200 D D D NK ---

NKII0007 NK24 BAT CHARGER AMPS 3501 J-200 D D D NK ---

NKII0008 NK14 BAT AMPS 3501 J-200 D D D NK ---

NN001 VITAL AC INST DIST PANEL 3408 E-053 D D D NN BOTH NN002 VITAL AC INST DIST PANEL 3410 E-053 D D D NN BOTH NN003 VITAL AC INST DIST PANEL 3414 E-053 D D D NN BOTH NN004 VITAL AC INST DIST PANEL 3404 E-053 D D D NN BOTH NN011 INVERTER 3408 ESE-18 D D D NN BOTH NN012 INVERTER 3410 ESE-18 D D D NN BOTH NN013 INVERTER 3414 ESE-18 D D D NN BOTH NN014 INVERTER 3404 ESE-1 D D D NN BOTH NN015 UPS/ INVERTER 3301 M-766A D D D NN ---

NN016 UPS/ INVERTER 3302 M-766A D D D NN ---

PA003 PT CUB. FOR RCP MOTOR DPBB01A 1410 E-009 C D D PA BOTH PA004 PT CUB. FOR RCP MOTOR DPBB01B 1410 E-009 C D D PA BOTH PA005 PT CUB. FOR RCP MOTOR DPBB01C 1409 E-009 C D D PA BOTH PA006 PT CUB. FOR RCP MOTOR DPBB01D 1409 E-009 C D D PA BOTH

21 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 22 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B RL001 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL002 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL003 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL004 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL005 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL006 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL011 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL012 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL013 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL014 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL015 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL016 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL017 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL018 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL019 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL020 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL021 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL022 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL023 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL024 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL025 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL026 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL027 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RL028 MAIN CTRL BOARD 3501 J-200 D D D RL BOTH RP053AA BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053AB BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053AC BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053BA BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053BB BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053BC BOP INSTR RACK 3605 J-110 D D D RP BOTH RP053DA BOP INSTR RACK TERMN 3605 J-110 D D D RP BOTH RP053DB BOP INSTR RACK TERMN 3605 J-110 D D D RP BOTH RP068 MISC BOP CONT PNL 3605 J-201 D D D RP ---

RP080 RVLIS MICROPROCESSOR 3605 ESE-51 D D D RP --- 26 RP081A SUBCOOLING MONITORING PANEL 3605 ESE-46A D D D RP --- 26 RP081A-E01 SUBCOOLING MONITOR PANEL 3605 ESE-46B D D D RP --- 26 RP081B SUBCOOLING MONITORING PANEL 3605 ESE-46A D D D RP --- 26 RP081B-E01 SUBCOOLING MONITOR PANEL 3605 ESE-46B D D D RP --- 26 RP118A AUX SHUTDOWN PNL 1413 J-201 D D D RP BOTH RP118B AUX SHUTDOWN PNL 1413 J-201 D D D RP BOTH RP139 AUX RELAY RACK 3301 E-093 D D D RP BOTH RP140 AUX RELAY RACK 3302 E-093 D D D RP BOTH RP147A INSTR RACK 3302 J-110 D D D RP ---

RP147B INSTR RACK 3302 J-110 D D D RP ---

RP210 AUX RELAY RACK 1402 E-093 D D D RP BOTH 33 RP266 AUX RELAY RACK 1408 E-093 D D D RP BOTH 33 RP289 125 VDC PANEL 1513 E-028 D D D RP --- 34 RP290 125 VDC PANEL 1501 E-028 D D D RP ---

22 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 23 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B RP315 125 VDC PANEL K105 E-028 D D D RP ---

RP316 125 VDC PANEL K104 E-028 D D D RP ---

RP331 REVERSE ISOL RELAY RACK 1408 E-093 D D D RP BOTH 33 RP333 AUX. RELAY RACK 1408 E-093 D D D RP BOTH 33 RP334 LOCKOUT RELAY RACK 3302 E-093 D D D RP BOTH RP335 LOCKOUT RELAY RACK 3302 E-093 D D D RP BOTH SA036A ESFAS CABINET 3605 J-104 D D D SA BOTH SA036B ESFAS CABINET 3605 J-104 D D D SA BOTH SA036C ESFAS CABINET 3605 J-104 D D D SA BOTH SA036D ESFAS CABINET 3605 J-104 D D D SA BOTH SA036E ESFAS CABINET 3605 J-104 D D D SA BOTH SA066A CAB. STATUS LOGIC/TERM. 3605 E-094 D D D SA ---

SA066B CAB. STATUS LOGIC/TERM. 3605 E-094 D D D SA ---

SA066C CAB. STATUS LOGIC/TERM. 3605 E-094 D D D SA ---

SA066X STATUS LIGHT DISPLAY PANEL 3501 E-094 D D D SA ---

SA066Y STATUS LIGHT DISPLAY PANEL 3501 E-094 D D D SA ---

SA066Z STATUS LIGHT DISPLAY PANEL 3501 E-094 D D D SA ---

SA075A MN STM & FW ISO ACT PNL 3605 J-105 D D D SA BOTH SA075B MN STM & FW ISO ACT PNL 3605 J-105 D D D SA BOTH SB029A CAB W SS PROT SYS INPUT TRN A 3605 ESE-16 D D D SB BOTH SB029B CAB W SS PROT SYS LOGIC TRN A 3605 ESE-16 D D D SB BOTH SB029C CAB W SS PROT SYS OUT 1 TRN A 3605 ESE-16 D D D SB BOTH SB029D CAB W SS PROT SYS OUT 2 TRN A 3605 ESE-16 D D D SB BOTH SB030A CAB W SAFEGUARDS TEST 1 TRN A 3605 ESE-16 D D D SB BOTH SB030B CAB W SAFEGUARDS TEST 2 TRN A 3605 ESE-16 D D D SB BOTH SB032A CAB W SS PROT SYS INPUT TRN B 3605 ESE-16 D D D SB BOTH SB032B CAB W SS PROT SYS LOGIC TRN B 3605 ESE-16 D D D SB BOTH SB032C CAB W SS PROT SYS OUT 1 TRN B 3605 ESE-16 D D D SB BOTH SB032D CAB W SS PROT SYS OUT 2 TRN B 3605 ESE-16 D D D SB BOTH SB033A CAB W SAFEGUARDS TEST 1 TRN B 3605 ESE-16 D D D SB BOTH SB033B CAB W SAFEGUARDS TEST 1 TRN B 3605 ESE-16 D D D SB BOTH SB037 CAB W PROCESS PROTECTION SET 3 3605 ESE-13 D D D SB BOTH SB038 CAB W PROCESS PROTECTION SET 1 3605 ESE-13 D D D SB BOTH SB041 CAB W PROCESS PROTECTION SET 4 3605 ESE-13 D D D SB BOTH SB042 CAB W PROCESS PROTECTION SET 2 3605 ESE-13 D D D SB BOTH SB078 RVLIS MICROPROCESSOR CABINET 3605 ESE-51 D D D SB --- 26 SB079 RVLIS MICROPROCESSOR CABINET 3605 ESE-51 D D D SB --- 26 SB102A CAB W REACTOR TRIP SWGR TRAIN A 1403 ESE-62 D D D SB BOTH SB102A-E01 CAB W REACTOR TRIP SWGR TRAIN A 1403 ESE-20 D D D SB BOTH SB102B CAB W REACTOR TRIP SWGR TRAIN B 1403 ESE-62 D D D SB BOTH SB102B-E01 CAB W REACTOR TRIP SWGR TRAIN B 1403 ESE-20 D D D SB BOTH SB148A CAB W CONTR RM ISOL 3302 ESE-13 D D D SB BOTH SB148B CAB W CONTR RM ISOL 3302 ESE-13 D D D SB BOTH SBUQ0761A SSPS POWER SUPPLY IN SB038 3605 ESE-13 D D D SB BOTH SBUQ0761B SSPS POWER SUPPLY IN SB038 3605 ESE-13 D D D SB BOTH SBUQ0761C SSPS POWER SUPPLY IN SB038 3605 ESE-13 D D D SB BOTH SBUQ0762A SSPS POWER SUPPLY IN SB042 3605 ESE-13 D D D SB BOTH SBUQ0762B SSPS POWER SUPPLY IN SB042 3605 ESE-13 D D D SB BOTH

23 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 24 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B SBUQ0762C SSPS POWER SUPPLY IN SB042 3605 ESE-13 D D D SB BOTH SBUQ0763A SSPS POWER SUPPLY IN SB037 3605 ESE-13 D D D SB BOTH SBUQ0763B SSPS POWER SUPPLY IN SB037 3605 ESE-13 D D D SB BOTH SBUQ0763C SSPS POWER SUPPLY IN SB037 3605 ESE-13 D D D SB BOTH SBUQ0764A SSPS POWER SUPPLY IN SB041 3605 ESE-13 D D D SB BOTH SBUQ0764B SSPS POWER SUPPLY IN SB041 3605 ESE-13 D D D SB BOTH SBUQ0764C SSPS POWER SUPPLY IN SB041 3605 ESE-13 D D D SB BOTH SE001 WELL DET. (NE41) 2000 ESE-8 C D C SE BOTH SE002 WELL DET. (NE31 NE35) 2000 ESE-4 C D C SE ---

SE003 WELL DET. (NE43) 2000 ESE-8 C D C SE BOTH SE005 WELL DET. (NE42) 2000 ESE-8 C D C SE BOTH SE006 WELL DET. (NE32 NE36) 2000 ESE-4 C D C SE ---

SE007 WELL DET. (NE44) 2000 ESE-8 C D C SE BOTH SE031 PREAMP SR CHAN 1 1410 ESE-47B C D D SE ---

SE032 PREAMP SR CHAN 2 1409 ESE-47B C D D SE ---

SE054A W NUC INST. NIS 1 3605 ESE-10 D D D SE BOTH SE054B W NUC INST. NIS 2 3605 ESE-10 D D D SE BOTH SE054C W NUC INST. NIS 3 3605 ESE-10 D D D SE BOTH SE054D W NUC INST. NIS 4 3605 ESE-10 D D D SE BOTH SENI0060A EX-CORE NEUTRON FLUX INDICATOR 3501 J-110 D D D SE ---

SENI0060B EX-CORE NEUTRON FLUX INDICATOR 3501 J-110 D D D SE ---

SENI0061X EX-CORE NEUTRON FLUX INDICATOR 1413 J-110 D D D SE ---

SENI0061Y EX-CORE NEUTRON FLUX INDICATOR 1413 J-110 D D D SE ---

SENIR0061 EX-CORE NEUTRON FLUX RECORDER 3501 J-110 D D D SE ---

SENY0060A NFMS AMPLIFIER 1403 J-364 D D D SE ---

SENY0060B NFMS SIGNAL PROCESSOR 1403 J-364 D D D SE ---

SENY0061A NFMS AMPLIFIER 1501 J-364 D D D SE ---

SENY0061B NFMS SIGNAL PROCESSOR 1501 J-364 D D D SE ---

SGK04A CONTROL ROOM A/C UNIT 1512 M-622.1, M-622.1ADD D GK BOTH SGK04B CONTROL ROOM A/C UNIT 1501 M-622.1, M-622.1ADD D GK BOTH SGK05A CLASS IE ELEC. EQUIP. A/C UNIT 3416 M-622.1, M-622.1ADD D GK BOTH SGK05B CLASS IE ELEC. EQUIP. A/C UNIT 3415 M-622 D D D GK BOTH SGS03A H2 ANALYZER CALIB BOTTLE & CTRL PANEL SKID 1506 J-359 D D D GS --- 34 SGS03B H2 ANALYZER CALIB BOTTLE & CTRL PANEL SKID 1507 J-359 D D D GS --- 34 SJ359 CONTROL BOX FOR SJHV0006 1301 WEST J-603A D D D SJ --- 30 SP067 RAD MONITOR CONT PNL 3605 J-361 D D D SP ---

SP104A RAD MON SYS ISOLATION BOX 1513 J-361 D D D SP --- 34 SP104B RAD MON SYS ISOLATION BOX 1513 J-361 D D D SP --- 34 SP105A RAD MON SYS ISOLATION BOX 1513 J-361 D D D SP --- 34 SP105B RAD MON SYS ISOLATION BOX 1513 J-361 D D D SP --- 34

24 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 25 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B SP122A RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP122B RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP127A RAD MON SYS ISOLATION BOX 6301 J-361 D D D SP --- 36 SP127B RAD MON SYS ISOLATION BOX 6301 J-361 D D D SP --- 36 SP128A RAD MON SYS ISOLATION BOX 6301 J-361 D D D SP --- 36 SP128B RAD MON SYS ISOLATION BOX 6301 J-361 D D D SP --- 36 SP131A RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP131B RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP132A RAD MON SYS ISOLATION BOX 1506 J-361 C D D SP --- 34 SP132B RAD MON SYS ISOLATION BOX 1506 J-361 C D D SP --- 34 SP133A RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP133B RAD MON SYS ISOLATION BOX 1507 J-361 C D D SP --- 34 SP159A RAD MON SYS ISOLATION BOX 1512 J-361 D D D SP ---

SP159B RAD MON SYS ISOLATION BOX 1512 J-361 D D D SP ---

SP160A RAD MON SYS ISOLATION BOX 1501 J-361 D D D SP ---

SP160B RAD MON SYS ISOLATION BOX 1501 J-361 D D D SP ---

SS001 AMSAC PANEL 3605 J-203 D D D SS ---

XNG01 LC TRANSFORMER 3301 E-017 D D D NG BOTH XNG02 LC TRANSFORMER 3302 E-017 D D D NG BOTH XNG03 LC TRANSFORMER 3301 E-017 D D D NG BOTH XNG04 LC TRANSFORMER 3302 E-017 D D D NG BOTH XNG05 ESW MCC TRANSFORMER K105 E-075 D D D NG BOTH XNG06 ESW MCC TRANSFORMER K104 E-075 D D D NG BOTH XNN05 XFMR 3408 E-075 D D D NN BOTH XNN06 XFMR 3408 E-075 D D D NN BOTH ZHS-1-EQ SWITCHES 1410 E-028A D D D XX BOTH ZHS-2-EQ SWITCHES 1409 E-028A D D D XX BOTH ZZP-1-EQ PREFABRICATED CABLE ASSEMBLIES (E-11014) 2 - Used E-095 (Bendix) C C C XX BOTH throughout the plant

Cat. A Item is required to function post accident Cat. B Item is not required to function post accident; however, item must not adversely fail post accident Cat. C Item's status post accident has no effect on plant safety Cat. D Item is in mild environment post accident

25 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 26 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B Notes:

2 Used throughout the plant.

3 The spent fuel pool cooling system will be operated during these conditions to maintain fuel pool temperatures.

This note identifies that Non-IE Conax modules used in this penetration and addressed in PQE-E-035B-P01 have a safety related function of maintaining 4 the pressure boundary of containment. PQE-E-035B-P01 documents that Conax modules used in ZSE/ZSI222E (I), ZSE/ZSI252E (I), ZNE/ZNI253C (I),

ZSE/ZSI254E (I), ZSE/ZSI255E (I), ZSE/ZSI255D (I), ZNE/ZNI292F (I) and ZNE/ZNI294C (I) ZSE/ZSI222F (LVP), ZNE/ZNI224C (LVP), ZNE/ZNI274A (LVP), ZNE/ZNI274G (LVP) and ZNE/ZNI282C (LVP) are acceptable for use in the environments identified.

5 Used throughout the plant - outside containment.

7 Used inside containment.

8 Splices used inside boxes instead of terminal blocks.

9 Alternate EGS connector approved for installation per CP 12467 as necessary.

Determined by XX-81 analysis to be mild environment equipment post accident (also reference EQWP-J-605A R3) states that a location-specific dose 11 calculation and analysis was performed on the butterfly valves located in Room 1314, and concluded that the subject valves can be recategorized as mild environment equipment. The parameters constitute a mild environment.

Determined by XX-53 analysis to be mild environment equipment post accident. EQWP-E-018 R5 states that a specific-location dose calculation and 12 analysis was performed on the MCC's located in Room 1409 and 1410, and concluded that subject MCCs can be recategorized as a mild environment equipment.

16 Qualified as a sub-component of Panel RP209 17 Qualified as a sub-component of Panel RP330 18 Qualified as a sub-component of Panel RP332 19 Spared in Place 20 This equipment was added in response to NUREG-0737 Category II.B.1 21 This equipment was added in response to NUREG-0737 Category II.B.3 22 This equipment was added in response to NUREG-0737 Category II.D.3 24 This equipment was added in response to NUREG-0737 Category II.E.1.2 25 This equipment was added in response to NUREG-0737 Category II.F.1 26 This equipment was added in response to NUREG-0737 Category II.F.2 27 Rooms 1101, 1102, 1120, 1121, 1122 and 1130 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

28 Rooms 1107 and 1108 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

29 Rooms 1113 and 1114 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

30 Rooms 1301, 1314, 1315 and 1320 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

31 Rooms 1508 and 1509 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

32 Rooms 1206 and 1207 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

26 of 27 # Internal Use Only EQSD-II Rev. 35 Table 2: EQ Mild Environment Equipment List 27 of 27

Component Number Environmental Qualification Description EQ Room EQ Spec L H M System Hot/Cold Notes O E S Shutdown C L L A B B 33 Rooms 1401, 1402 and 1408 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

Rooms 1502, 1503, 1505 and 1507 plus Rooms 1504, 1506 and 1513 (due to transfer grill GLD0175 on M-1H1431) are all open to one another. A worst-34 case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

35 Rooms 3401, 3406 and 3412 are all open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

36 Rooms 6301 and 6302 are open to one another. A worst-case condition of any associated room boundary breach should be addressed for components in all of these rooms for the HELB barrier consideration in AP 10-104.

Reference E-035B-00050, Table 3.1, Page 11. The power and control modules are ZSE/ZSI233E, ZSE/ZSI233F, ZSE/ZSI234F, ZNE/ZNI278F and ZNE/ZNI278G. The instrumentation modules are ZSE/ZSI233D, ZSE/ZSI233G, ZSE/ZSI234E, ZSE/ZSI243C, ZSE/ZSI249C, ZSE/ZSI249D, 37 ZSE/ZSI250A, ZSE/ZSI250B, ZSE/ZSI250D, ZSE/ZSI250F, ZSE/ZSI250G, ZSE/ZSI258F, ZNE/ZNI277F, ZNE/ZNI278C, ZNE/ZNI278D, ZNE/ZNI278E, ZNE/ZNI279E, ZNE/ZNI287C, ZNE/ZNI287D, ZNE/ZNI287E, ZNE/ZNI288B, ZNE/ZNI288D, ZNE/ZNI288F, ZNE/ZNI295F and ZNE/ZNI295G.

GDI-30F (Long-glass, fiber filled, diallyl-phthalate) terminal blocks that are Series 601-JJ, 602-JJ, 604-JJ, 605-JJ, 812-JJ type are qualified under PQE-E-38 035B-P02 for each of these applications. Instrumentation applications do not use the Kulka terminal blocks inside the containment, PQE-E-11013-P01/

P06/P07/ P08/ P09 splices are used in these applications.

These assets contain two limit switches. However one of the limit switches is an installed spare and doesnt have power running to it. Therefore, doesnt 39 perform any safety function and doesnt need qualified by the EQ program.

50 Located in yard.

27 of 27 # Internal Use Only