APPENDIX

NOTICE OF VIOLATION

Commonwealth Edison Company Docket No. 50-454

As a result of the inspection conducted on September 4 - October 1,1985, and

in accordance with the General Policy and Procedure for NRC Enforcement

,!

Actions, (10 CFR Part 2, Appen' dix C), the following violations were

identified:

e

1. Technical Specification 4.2.1.1.la(2) states, in part: "The

indicated AFD shall be determined to be within its limits during

power OPERATION...by... monitoring the indicated AFD of.each OPERABLE

excore channel...at least once per hour for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after i

restoring the AFD Monitor Alarm to OPERABLE status."

Contrary to the above, on August 9 - 10, 1985, while in Mode 1, the i

indicated AFD was not monitored hourly for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> following the

restoration to OPERABLE status of the AFD Monitor Alarm.

i;

This is a Severity Level IV violation (Supplement I). .

(454/85039-01(DRP))

2. Technical Specification 4.0.2 required that each surveillance

requirement shall be performed within the specified time interval

with a maximum allowable extension not to exceed 25% of the

surveillance interval. ,

Technical Specification 4.4.6.2.1.d required that a Reactor Coolant

System water inventory balance be performed at least once per 72 l

hours. t

Contrary to the above, on August 20, 1985, while in Mode 1, the

Reactor Coolant Systen water inventory balance was not perforned

within the required surveillance interval.

This is a Severity Level IV violation (Supplement I).

(454/85039-02(DRP))  :

,

4

N

G

AO 4 ,

,1

i

!

',

1_&' '

. __

. .

.

'

Appendix -2- [

< The inspection showed that actions had been taken to correct the identified i

'

violations and to prevent recurrence. Consequently, no reply to these

violations is required and we have no further questions regarding these

matters. i

!

!

!

,