ML20140A330

From kanterella
Revision as of 00:16, 15 June 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Verification Letter of the Approval Version of Westinghouse Electric Company Topical Report Quality Management System (Qms), Revision 8.0
ML20140A330
Person / Time
Site: Westinghouse
Issue date: 05/20/2020
From: Dennis Morey
Licensing Processes Branch
To: Zozula C
Westinghouse
Lenning E
References
EPID L-2020-TOP-0022
Download: ML20140A330 (2)


Text

May 20, 2020 Ms. Camille Zozula, Manager Infrastructure & Facilities Licensing Westinghouse Electric Company 1000 Westinghouse Drive Building 1, Suite 165 Cranberry Township, PA 16066

SUBJECT:

VERIFICATION LETTER OF THE APPROVAL VERSION OF WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT QUALITY MANAGEMENT SYSTEM (QMS), REVISION 8.0 (EPID L-2020-TOP-0022)

Dear Ms. Zozula:

By letter dated May 19, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20140A288), Westinghouse Electric Company (Westinghouse) submitted to U.S. Nuclear Regulatory Commission (NRC) an approval (-A) version of Quality Management System (QMS), Revision 8.0 Topical Report (TR). Westinghouse has done so in accordance with our request to publish an approval non-proprietary version of this TR, as detailed in the transmittal letter of the NRC staffs final safety evaluation (SE) that documented its review of the Westinghouse TR Quality Management System (QMS), Revision 8.0, to extend the period for supplier audits due to COVID-19 (ADAMS Accession No. ML20132A303).

The NRC staff has completed its review of the approval version of the TR. The NRC staff verified that Westinghouse has met the requirements and determined that the submitted -A versions are acceptable for referencing in licensing applications for nuclear power plants to the extent specified, and under the limitations delineated in the NRC staffs SE and accepted versions of the TR. TR Quality Management System (QMS), Revision 8.0, is now approved for use in future licensing actions.

Please contact Ekaterina Lenning of my staff at (301) 415-3151 if you have any questions on this subject.

Sincerely,

/RA/

Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902038

ML20140A330 *via e-mail OFFICE NRR/DORL/LLPB/PM* NRR/DORL/LLPB/LA* NRR/DRO/IQVB/BC* NRR/DORL/LLPB/BC*

NAME ELenning DHarrison KKavanagh DMorey DATE 05/19/2020 05/20/2020 05/20/2020 05/20/2020